1. JY997D33701B Side B E A JAPANESE B ENGLISH a MITSUBISHI PROGRAMMABLE CONTROLLERS MELSEG F FX3G 8AV BD INSTALLATION MANUAL Manual Number JY997D33701 es ooo September 2008 Changes for the Better F X 3G This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company and product names described in this manual are registered trademarks or the trademarks of their respective companies Effective September 2008 Specifications are subject to change without notice 2008 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories DANGER and A CAUTION Indicates that incorrect handling may cause hazardous DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on the circumstances procedures indicated by CAUTION may also cause severe injury It is imp
2. e connector 1 2 1 Trimmer Layout afore sil 2 Installation INSTALLATION PRECAUTIONS DANGER e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS CAUTION e Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur Use screwdrivers carefully when performing installation work thus avoiding accident or product damage When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect the expansion board securely to their designated connectors Loose connections may cause malfunctions Unit mm inches Connector cover is The following section describes the installation method to the FX3G Series PLC FX3G 40ML In this example Turn off the
3. el name Applicability FX3G Series PLC Ver 1 10 or later e Only one analog volume expansion board can be used per main unit Never stack up two or more expansion boards For details on the system configuration refer to the following manual Refer to the FX3G Series User s Manual Hardware Edition 3 2 General Specifications The general specifications are equivalent to the PLC main unit For general specifications refer to the following manuals Refer to the FX3G Series User s Manual Hardware Edition 3 3 Performance specifications Item Specification Analog volume points 8points VRRD FNC 85 Volume Read Instruction VRSC FNC 86 Volume Scale VRRD instruction 0 to 255 Digital conversion value lt 0 instruction 0 to 10 For instructions refer to the following manuals Refer to the FX3G FX3U FX3uUC Series Programming Manual This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unp
4. ortant to follow all precautions for personal safety Associated Manuals Manual name Description FX3G Series JY997D31301 Explains the FX3G Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R521 installation and maintenance FX3G FX3U FX3UC Series Programming JY997D16601 Describes PLC programming for Manual MODEL CODE basic applied instructions and 09R517 Basic amp Applied devices Instruction Edition This manual describes the specifications and installation details for the FX3G 8AV BD For system configuration and program examples refer to the following manuals Refer to the FX3G Series User s Manual Hardware Edition Refer to the FX3G FX3U FX3UC Series Programming Manual How to obtain manuals For product manuals or documents consult with the Mitsubishi Electric dealer from who you purchased your product 1 Outline FX3G 8AV BD is an expansion board equipped with eight analog set points which can be used as an analog timer 1 1 Incorporated Items Product Analog volume expansion board FX3G 8AV BD M3x8 tapping screws for installation 2 pcs Included Trimmer layout label items Side cover Installation Manual This manual 1 2 External Dimensions and Part Names 3 2 removed 1 35 1 38 1 Analog volume 2 Mounting holes 2 03 2 3 Connector cover 4 Main unit connector 5 Memory cassette Display modul
5. power to the PLC before installation For more details on installation and removal refer to the PLC main unit manual Refer to the FX3G Series User s Manual Hardware Edition 2 1 Installation Method 1 Remove the top cover A in the figure on the right Caution FX3G 8AV BD cannot attach in the top cover S side of a 40 60 point types main unit 2 Attach the accessory side cover B in the figure on the right 3 Make sure the expansion board is in parallel with the main unit and attach it to the optional equipment connector 4 Fix the expansion board to the main unit using the provided M3 tapping screws 2 places Tightening torque 0 3 to 0 6 N m 3 Specifications STARTUP AND MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric distributor e Do not drop the product or exert strong impact to it Doing so may cause damage DISPOSAL PRECAUTIONS CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device TRANSPORT AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product 3 1 Applicable PLC Mod
6. redictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN