1. Clean the headgear in accordance with the information in the headgear manufacturer s user s manual HOFFRICHTER GmbH Mettenheimer Str 12 14 19061 Schwerin Germany Phone 49 385 39925 0 Fax 49 385 39925 25 E mail info hoffrichter de www hoffrichter de point re kurz eng 0310 01 Art no 5000 0289 HOFFRICHTER Quality makes the Difference E E m m Therapy tube connection Programming keys Enter key Display ON OFF key Cover for contact sockets for plug in humidifier Rating plate Filter or connection port for the filtersystempoint 9 Pressure balance aperture grid covered 10 RS232 interface 11 Power socket Brief Instruction CPAP Respiratory Therapy Device Oy Or ODO ON as of device software 2 101 This document does not replace the manufacturer s user s p manual Follow the user s manual COMMISSIONING 1 10 Set up the device according to the installation instruc tions See user s manual Connect the power supply to the device Connect the mains cable to the power supply and plug into a power socket The device starts up and displays a welcome text the software version and the current number of therapy hours and then switches to the date and time display Connect the therapy tube a to the air outlet and b to the mask In some cases the device must be calibrated To do this read the Calibration section in the user s manual Put the mask on
2. CHANGING THE FILTER CLEANING A CAUTION Make sure that you follow the cleaning instruc tions If you do not do this it could damage your health because of germs CHANGING AND CLEANING THE FILTER CAUTION If the filter is dirty or if a gt FILTE lt message appears on the display the filter must be replaced or washed out Changing the filter Pull out the filter from the back of the device and replace it with a new one or a cleaned one Cleaning the filter 1 Pull out the filter from the back of the device 2 Use mild soapy water for cleaning do not use any other agents Rinse thoroughly with clear water and leave to dry in the air J Hill hPa FILTER 2215 Removing the filter Cleaning the mask daily 1 Remove the mask with the exhalation valve from the therapy tube 2 Use mild soapy water for cleaning do not use any other agents Rinse thoroughly with clear water and leave to dry in the air protected from direct sunlight Cleaning the therapy tube weekly 1 Remove the therapy tube from the device and the mask 2 Use mild soapy water for cleaning Rinse the tube thoroughly with clear water and leave to dry in the air Cleaning the device weekly 1 Unplug the mains plug 2 Wipe the device with a cloth slightly moistened with soapy water and then rub dry Cleaning the headgear If necessary the headgear must be cleaned as follows 1 Remove the headgear from the mask 2
3. If automatic mode has been selected the device is turned on by the patient breathing pow erfully In manual mode press the ON OFF key to start the device The device first of all runs for the time selected by you for the mask test and at the prescribed pressure You should now ensure that the mask is fitted correctly to ensure that it does not leak Place the tube in such a way that it does not exert any strain on the mask when you lie down Now breath deeply and calmly still just through your nose Gan G Nj eo 8 9 MENUS The point has a standard menu and a complete menu To switch between the menus press Then hold the A and W keys down at the same time for a few moments The display shows the following message Comp lete Henu Standardttenu or active active SETTING PARAMETERS The following 3 keys are available to set the parameters on the device A Programming key Y Programming key Enter key 1 Press for approx 1 second 2 If necessary select the standard or the complete menu 3 Press A to switch to the next parameter A flashing triangular symbol denotes the active parameter 4 Press to change a parameter 5 Set the required value with A and V 6 Confirm the new value by pressing MPORTANT The therapy pressure setting is PIN code secured Settings may only be performed by the physician SWITCHING THE ALARM ON AND OFF e The alarm wake function is set by pre
4. ssing A A bell symbol appears in the display e The alarm wake function is unset again by pressing V The bell symbol disappears SETTING THE WAKE UP TIME 1 Press for approx 1 second Press the A and W key to select Lake Timne Confirm by pressing Press A and to set the wake up time Confirm the set wake up time by pressing ar wn ACCESSORIES optional Therapy air humidifier aquapoint Filter system filtersystempoint Battery pack powerpackpo nt Please refer to the respective user s manual for further information

Download Pdf Manuals

image

Related Search

Related Contents

Manual del usuario de Approach® S4  M30262T-PTC  ML10i/ML11i 取扱説明書  Capítulo Índice Capítulo Índice Capítulo Capítulo  Oracle® Solaris Cluster 4.3 Licensing Information User Manual  

Copyright © All rights reserved.
Failed to retrieve file