XINJE XP/XMP
Contents
1. 1 N2JP SA lP Ae pu Z VE Rel ay out put Note T type has no relay output do not connect AC220V or the product will be broken Constitution of output circuit l For DC inductor load please parallel connect with commutate diode If not connect with the commutate diode the point s life will be decreased greatly Please choose the commutate diode which allow inverse voltage endurance up to 5 10 times of the load s voltage ordinal current exceeds load current l Parallel connect AC inductor load with surge absorber can reduce noise and extend useful life of the points DC load inductor load output point commutate diode 20 2 3 Transistor output specs and circuit output point inductor load surge absorber Transistor output can divide into two types high speed pulse output and normal transistor output High speed pulse output RT output Type T output High speed pulse output point You Y1 YO Y1 Power supply Below DC5 30V Maximum current 50mA Maximum freguency pulse 200KHZ Normal transistor output Type RT output T output Transistor output point Y2 Y3 Y2 Y7 Power supply Below DC5 30V Circuit insulation Optical coupling insulation Maximum load Resistor load 0 4
2. Input connection Because there is no 24V power supply inside XP XMP it needs an outside supplier to drive the photo electricity switch sensor The supplier should be DC 24V 4V The output transistor of sensor should be NPN open collector DC pover suppl y V aN lt 5 gt Z pS XO LED Y y SITE zima gt S xj pover supply XTE gt DON sensor Input points Connect input point and com point with non voltage point or NPN open collector transistor to turn on the input Input loop The first loop and the second loop are insulated by optical coupler the second loop has C R filter which can prevent wrong action caused by industry noise or input points oscillation As the result there will be a response delay for 10ms to the input points There is digital filter in the input points Input sensitivity Input current is DC 24V 7mA To make the input reliable the ON current should be above 3 5mA the OFF current should be below 1 5mA Typical connection 2 2 Relay output specs and circuit Relay output specs Type R RT output T output Relay output RO Y0 Y7 RI Y4 Y7 Power supply Below AC250V DC30V Circuit insulation Machinery insulation Action indication Pr
3. The configuration method and using details please refer to BD Board Manual 41 5 2 Extend MA model XP XMP can extend MA model via RS 485 com port A and B point in order to control and measure analog quantity The type and specs of MA model are as below MA model type Type Function MA 8X8YR 8 channels digital input 8 channels digital output MA 16X 16 channels digital input MA 16YR T 16 channels digital output MA 4DA 4 channels analog output MA 4AD 4 channels analog input MA SAD A V 8 channels analog input MA 4AD2DA 4 channels analog input 2 channels analog output MA 6TC P 6 channels type K thermocouple temperature control MA 6PTP 6 channels PT100 temperature control MA model specs Type MA 8X8YR Descr iption 8 channels digital input 8 channels digital relay output MA 16X 16 channels digital input MA 16YR 16 channels digital relay output MA 16YT 16 channels digital transistor output MA 4DA NEMI mami Analog output range exterior load resistor less than 2K IM 500 Digital input range 10 bits binary numbers exterior load resistor DC24V 10 100mA 42 Profile dimension 63mmX 102mmX 73 3mm MA SAD A V DOOD 2090 40 2008 Analog input range exterior load resistor exterior load resistor less than 2K IM 500 oma Digital output range 12 bits binary nu
4. O TU Counter 0 el Flash ROM Register FD 510 words 512 words 2048 words High speed processing High speed count pulse output function external interrupt Setting of time scan space 0 99mS Self diagnose function Power on self diagnose Monitor timer grammar check Note The user program capacity is referred to the capacity under secret downloading mode 1 3 Parts explanation Screen area XINJE A ESC ALM SET Y ENT SO Dell A AA OO MODE XP3 18R SNOJ 20060502118 Program DATED 20060510 port 0000000000000 Points 00000000 Power supply 244 OV A B COMO YO Y1 Y2 Y3 COMIY4 YS Y6 Y7 COM XO XI X2 X3 X4 X5 X6 X7 X10 XTI f RS 485 Com port Output points In out points arrangement with BD board connect 24V OV A B COMOYO Y1 Y2 Y3 COM1Y4 YS Y6 Y7 COM XO XI X2 X3 X4 X5 X6 X1 X10 X11 24V OV power supply input A B RS 485 com port COM common ground Program port Program port is a RS 232 com port which has double functions of downloading PLC program and HMI pictures The pins function of the port is as below Function CE Xinje provides special program cable to download the PLC program or HMI program You also in XD GND RTS can make the ca
5. the OP will communicate with XC inside the product the communication parameters are defaulted Select PLC xX Select the tyne of PLC connected PLC Type Xinje KC zl Set communication parameter Setting Cancel 4 edit the screen After these three steps we can enter screen editing mode For the editing details please refer to OP Series Display User Manual chapter 2 Edit Tool Untitled File Edit Tool Help plela fee oleaje all al pise aj i AO re TENA ee ee ee al al ex A A AA ae AA E N tui g T te ne Sereen Attribute Description Previous Screen No 0 Next Screen No 2 zej rasa Muri 37 Screen download 1 Select com port Before downloading the screen select the correct com port The port is DB9 pins serial port of PC The computer will select the port automatically user only need to know the port number If user can not confirm which port to use try each port in file If the com port is wrong it will prompt you with the note can not open Download x A Can Not Open Comm Port COMS Click file comm port to select the correct com port Select Coma Port ES Select the communication port for Downloading Comm Port COM E Cancel 2 download Connect the XP XMP DB9 pins com port and PC serial port using download cable Power on the XP XMP click sl to start downloading mrko o Down
6. New Delete 4 2 Build a project About the software XP XMP series product integrated the function of HMI and PLC when editing the HMI screen use HMI software OP20 The interface of OP20 is shown as below dop Series Edit Tool Untitled M Function Key Attribute Coordinate p Function OE e e Hand I Disappea Encrypt ito od mo SetData Special F Double y M 0 Inverse Force UN C Force OFF C Reverse Momentary Ohi File Edit Tool Help olaa e ojejalx alae al p Screen Screg Description M Screen Attribute Description Previous Screen No 0 Next Screen No 2 New Delete INPaan frmPi 36 Build a project We take XMP3 18R as an example to explain how to build a project 1 build a new project Open the OP software click file new project or click LT to build a new project 2 choose the display type In the select model window choose the correct type of XP XMP For this example we select MP330 XMP Select Model ES Select Model C 0P320 C 0P330 xP This window shows all the display type OP320A MP330 SMP supported by OP software suo sijo We can select the correct type according to the C OP3IO C OP520 content in the bracket XP series should select OP330 XMP series should select MP330 Cancel 3 select PLC type As the XP XMP is a integrated product of OP and XC
7. can be set via software 31 MODE XP3 18R SND 20060502118 DATEQ 20060510 0000000000000 Sy RS 485 com port MOYO Y1 Y2 Y3 COMIY4 Y5 Y6 Y7 COM XO XI X2 X3 X4 X5 X6 X7 X10 X11 9 ES RS 485 com port Point A means signal point B means signal Attention XP1 XMPI series product can only be used as slaver station while using their RS 485 port to communicate with other devices Communication parameter Station No Modbus station No 1 254 255 FF is for free format communication Baud rate 300bps 115 2Kbps Data bit 8 or 7 bits Stop bit 2 or 1 bits Check Even odd no check The defaulted parameters of the port Station number is 1 baud rate is 19200bps 8 data bit 1 stop bit even check Parameter setting User can set com port parameters Please see below list for details Attention After changing the parameters in Flash register it is need to reboot the XP XMP to make the setting become effective 32 Number Function Description FD8220 Communication mode station number 255 is free format 1 254 is modbus station number FD8221 Communication format Baud rate data bit stop bit check FD8222 ASC timeout judgment time Unit ms O means no timeout waiting FD8223 Reply timeout judgment tim
8. compiling and software operating please refer to XC Series Edit Tool XCP Pro User Manual File Edit Search View PIC Operate PLC Setting Option Window Help jjoehxuG6ona rd AE Ye AE lt gt gt gt be ITA TE Project na x HE Project A e Ea pic B L Code EH Ladder nstruction List Func Block Config Block E Reg Comment Used Status Ex Free Monitor 29 Download the program 1 Connection Before downloading the program please ensure the XP XMP has connected with PC successfully The cable connection please refer to paragraph 1 3 Click to open software serial port configuration Hindow Help Communication Mode Config TEOX Device Config Func Block Config i um Software Serial Port Config Default Unlock Psw Config i B Instruction Tooltip Choose the correct serial port baudrate and parity or click check to choose these parameters automatically When below window shows connect to PLC succeeded it means the connecting is successful Click OK to continue Config Software ComPort L Serial Fort C Baudrate B coms O 4800BFS 9 19200EPS cone cone 3600BPS 36400BPS cons cont Parity E CoM cons None Odd Even Other set Databits amp Stopbit 1 Connect To PLC Succeeded Check DE Cancel If the connecting is not successful the window will show communication error Plea
9. the highest frequency is 200K Hz u R type unavailable 3 Interrupt function Channel Input Pointer tag Disable interruption Rising interruption Falling interruption instruction 10000 10001 M8050 10100 10101 M8051 10200 10201 M8052 4 Frequency measurement The point is X1 X11 X12 5 Pulse width modulation The point is YO Y1 u Ttype YO Y1 available u RT type YO Y1 available u R type unavailable 6 Precise timer 32 bit precise timer the timer range is T600 to T618 match with 10 interruption tag 3 2 soft component range XP XMP series soft component ID distribution list is as below If extending BD board the in out point definition please refer to XP Series Extended BD Board Manual 24 XP1 XMPlI series Soft component Name Range Points X Input points X000 X011 octal 10 Y Output points Y000 Y007 octal 8 Auxiliary relay MO0 M199 0 M200 M319 J For special using M8000 M8079 For special using M8120 M8139 For special using M8170 M8172 For special using M8238 M8242 For special using M8350 M8370 Process S0 S31 TO T23 100ms not accumulation T100 T115 100ms accumulation T200 T223 10ms not accumulation T300 T307 10ms accumulation T400 T403 1ms not accumulation T500 T503 1ms accumulation Counter C0 C23 16 bits plus counter C300 C315 32bits plus minus count
10. 16927 18432 18975 20480 21503 24576 25087 25600 26218 27648 28282 M odbus address hex H 0 1F3F 4000 421F 4800 4A 1F 5000 53FF 6000 61FF 6400 666A 6C00 6E7A Bit component address M0 M7999 X0 X 1037 0ctal Y0 Y 1037 octal S0 S1023 M8000 M8511 TO T618 C0 C634 Register space Modbus address prefix is 4x Word component M odbus address M odbus address address decimal K hexH DO D7999 0 7999 0 1F3F TDO TD618 12288 12906 3000 326A CD0 CD634 14336 14970 3800 3A7A D8000 D8511 16384 16895 4000 41FF FDO FD5000 18432 23432 4800 5B88 FD8000 FD8511 26624 27135 Free format communication 6800 69FF Free format communication transfer data in the format of data block each block can transfer 128 bytes at most Meanwhile each block can set a start symbol and a end symbol or not set When communicating in free format mode FD8220 should be 255 Start Symbol 1 byte Data Block max bytes 128 End Symbol 1 byte 34 4 HMI function and application 4 1 HMI function introduction The HMI part of XP XMP used OP330 MP330 series display The faceplate key press function is as below Whatever the mode of the display is in it will return to original system screen once you press the key the defaulted screen is No 1 Generally set the original system screen to be main menu or most used scree
11. 3999 O D4000 D4999 O D4000 D7999 For special using 7 register For special using D8000 D8511 D8000 D9023 D8630 D8729 FDO FD127 FDO FD1535 Data FlashROM register For special using For special using FD8000 FD8383 FD8000 FD8511 Extend data EDO ED16383 register NOTE X 1 The memorizer area in O is the defaulted power failure retentive area the power failure retentive area of soft components D M S T C can be set via FD register For the details please see the following table X 2 Flash ROM register needn t set power failure retentive area its data won t lose when 26 power is cut No battery X 3 The serial number of input coil and output relay are octal data other memorizers number are all decimal data X 4 There is no I O point connected with exterior device can be used as interior relay Soft component power failure area setting XP1 XMPI Soft Power failure Area Function Default value component memory area First address of the power FD8202 100 D100 D149 failure memory area of D First address of the power M FD8203 200 M200 M319 failure memory area of M First address of the power C FD8205 s 320 C320 C631 failure memory area of C First address of the power S FD8206 512 S0 S31 failure memory area of S XP2 XMP2 Soft 3 Power failure Area Function Default value component memory area First address of the power F
12. A Inductor load 12W DC24V Light load 1 5W DC24V Minimum load DC5V 2mA Repose time OFF gt ON Below 0 2ms ON gt 5 OFF Nor mal transistor output circuit Output point Below 0 2ms 21 There is one common point for basic unit transistor output Power supply The load circuit power supply should be steady voltage of DC5 30V Circuit insulation The inside circuit of XP XMP is insulated with output transistor by optical coupler Action indication When driving optical coupling LED lights output transistor is ON Response time From optical coupler driving or cut to transistor ON or OFF the time is below 0 2ms Output current The current is 0 4A per point But due to restriction of temperature going up the total current is 0 8A every four points Open current Less than 0 1mA To avoi d burni ng PLC basi c ci rcui t use sui tabl e fuse for the oad 1A COMx lt lt DC pover Load supply s YF D5 30V AN A 23 Load lt Y 5 lt 5 a 4 aR Load me E YK6 gt 2 gt ZK 4 Ri Load lt Y 7 aK de 22 3 PLC function and application 3 1 PLC instruction The XP XMP integrated with X
13. A Esc sle lese Jejejeje farm ser TI pra pes e p IZV e TI ao Y ENT pena hizo 6 7 8 9 ze mo F1 F2 F3 F4 a a eni S AJ F 8 0006 Aaa Se ale aaa XP XMP MA station No l MA station No 16 The details and using method please refer to MA Model Manual 5 3 Other extension Besides BD board and MA model XP XMP series product can extend other devices which support RS 485 and Modbus protocol XP XMP can extend 32 devices via RS 485 com port such as PLC meter printer inverter HMI etc The connection figure is as below XINJE FU ee en se NM ent 6 7 8 9 EER LIS ajajaja RS485 Modbus protocol Meter HMI Inverter MA module Attention The connection method is Bus mode transmission line should start from station 1 to station 2 then from station 2 to station 3 connect as this sequence until the last station Star mode or ring mode connections are not permitted 45
14. C series PLC The function of PLC is the same as XC series XP XMP Type Integrated PLC type XP1 XMPI series XCI series XP2 XMP2 series XC2 series XP3 XMP3 series XC3 series Instruction 1 XP1 XMPI series include SFC instructions and applied instructions exclude special function instructions 2 XP2 XMP2 series and XP3 XMP3 series have the same instructions They include SFC instructions applied instructions and special function instructions Please refer to XC Series PLC Manual paragraph 4 5 6 Special function instructions XP2 XMP2 and XP3 XMP3 have special function instructions please refer to XC Series PLC Operating Manual paragraph 6 Here we only give the port definition and distribution 1 High speed count X P2 X M P2 XP 3 X M P3 series Increase mode Pulse direction mode AB phase mode C600 C602 C604 C606 C608 C610 C612 C614 C616 C618 C620 C622 C624 C626 C628 C630 C632 C634 Highest 80K 80K 10K 10K 10K 80K 10K 10K 80K 5K 5K frequency 4 times frequency Count interruption X000 U U X001 U Dir B X002 X003 U U X004 Dir B X005 X006 U U X007 Dir B 23 X010 X011 U X012 2 High speed pulse output u Ttype YO Y1 available the highest frequency is 200K Hz u RT type YO Y1 available
15. D8202 4000 D4000 D4999 failure memory area of D First address of the power M FD8203 i 3000 M3000 M7999 failure memory area of M First address of the power T FD8204 j 640 No set failure memory area of T First address of the power C FD8205 320 C320 C639 failure memory area of C First address of the power S FD8206 512 S512 S1023 failure memory area of S XP3 XMP3 Soft Power failure Area Function Default value component memory area First address of the power FD8202 z 4000 D4000 D7999 failure memory area of D First address of the power T FD8204 i 640 No set failure memory area of T First address of the power M FD8203 2 3000 M3000 M 7999 failure memory area of M First address of the power T FD8204 640 No set failure memory area of T 27 First addr fth c E TOTARA a 320 C320 C639 failure memory area of C First address of the power S FD8206 512 S512 S1023 failure memory area of S First address of the power ED FD8207 ED0 ED16383 failure memory area of ED NOTE Users can set the power failure memory area but the area can not over the soft component area 3 3 Set up a project About the software The PLC program editing software is the same as Xinje XC series Software name is XCPPro The interface of software is as below EJE File Edit Search View PIC Operate PIC Setting Option Window Help DBeEbxeseeone Sloat 200923 ENE JR de dt e Ue lt gt gt lt gt 1 X Pana Se i Ins sIn
16. XINJ E X P X M P 18 series Integral industrial controller Operating manual Xinje Electronic Co Ltd Data No PHCO1 20080730 3 0 Xinje XP XMP 18 Seri es Cperati ng nanual Catalog Preface Safety Notes Input output specification and 2 exterior layout AAA 3 PLC Function and Application 4 HMI Function and Application 5 Extension Ability This manual includes some basic precautions which you should follow to keep you safe and protect the products These precautions are underlined with warning triangles in the manual About other manuals that we do not mention please follow basic electric operating rules 9 Please follow the precautions If not it may lead the controlsystem incorrect or abnormal even cause fortune lose The models could only be used according to the manual and an only be Correct used along with the peripheral eguipments recognized or recommended Application by Xinje Electronic They could only work normally in the condition of be transported kept and installed correctly also please operate and maintain them according to the recommendation Xinje Electronic Co Ltd Copyright reserved Without exact paper file allowance copy translate or using the manual is not allowed Disobey this people should take the responsibility of loss We reserve all the right of expansions and their design patent Duty Declare We have checked the manual its content fit
17. ble by yourself Please see the pin connection between PC and the port GND RR e GND RTS A RR CTS 3 TXD 3 TXD 5 7 Communication port Communication port A and B is a RS 485 com port This port is used to connect other devices Please refer to paragraph 3 4 for details 1 4 Outline dimension Outline dimension Unit mm 360 3 172 XINJE ESC SET ENT 111 121 TN 8 9 gt TI TI TI Re AY e fe ra a 5 r6 F FB 006 ma bel Installation dimension Unit mm 164 113 2 n out specs and exterior layout 2 1 Input specs Basic unit Input signal s DC24V 10 voltage Input signal s 7mA DC24V current Input ON current Above 4 5mA Input OFF current Below 1 5mA Input response time About 10ms Input signal s Contact input or format NPN open collector transistor Circuit insulation Photo electricity coupling insulation Input action s display LED light when input ON DC power suppl y DA 2 Noe RL XO X R4 DAY ale R3 X7
18. e Unit ms O means no timeout waiting FD8224 Start symbol High 8 bits invalid FD8225 End symbol High 8 bits invalid FD8226 Free format setting 8 16 bits cushion with without start bit with without stop bit IN The way of setting communication parameters FD8221 oL No check 1 Odd check 2 JEven check OL 2 stop bits 2 1stop bit FD8226 OL 300bps 1 600bps 2 1200 bps 3 2400 bps 4 4800 bps 5 9600 bps 6 19 2K bps 71 38 4K bps 8 57 6K bps 91 115 2K bps OL 8bits data 1 7bits data Reserved OL 8 bits communication 1 16 bits communication 0 without start symbol 1 with start symbol O without end symbol 1 with end symbol 33 M odbus communication XMP series product support master and slave mode of Modbus communication protocol Master format When PLC is set to be master station PLC sends reguest to other slave station devices via Modbus instructions other devices respond to the master station Slave format When PLC is set to be slave station it can only respond to other master devices The defaulted status of XMP is Modbus slave mode C ommunication address The internal soft unit s numbers of XMP are corresponded with Modbus station address numbers please see the following table Coil space Modbus address prefix is 0x M odbus address decimal K 0 7999 16384
19. e operating Manual purpose Suitable people Scope Tele document Contact us n This manual provides user with the guide of using and operating our product it includes the product characteristics spec explanation using method etc n This manual contains product summarization exterior layout PLC program and exterior extension Y Summarization introduce the product characteristics specs dimension installation Exterior layout introduce the product power spec in out layout PLC program introduce how to program in PLC HMI picture introduce how to edit picture in OP Ne E A IKI Exterior extension introduce extension ability of the product This manual aims to below users n Terminal user n Debugging person n Technology support person Make sure you have read the safety notice before operating This manual applies to the XP XMP series integral industrial controller Xinje provides user with press document and tele document n User CD Contained software manual and application examples n Xinje website Welcome to www xinje com download center to find electronic document If you have any questions please contact us Tel 86 0510 85134136 Fax 86 0510 85111290 Addr 4 Floor Building 7 Originality Industrial Park Liyuan Development Zone Wuxi City Jiangsu province China Safety notice Read the manual carefully before operating Be aware of the safety and correct operation The conten
20. er O C600 C603 vacant O C620 C621 vacant C630 C631 vacant Data register DO D99 O D100 D149 For special using D8000 D8029 For special using D8060 D8079 For special using D8120 D8179 For special using D8240 D8249 For special using D8306 D8313 For special using D8460 D8469 Flash ROM register FDO FD411 For special using FD8000 FD8011 For special using FD8202 FD8229 For special using FD8306 FD8315 For special using FD8323 FD8335 For special using FD8350 FD 8384 25 XP2 XMP2 and XP3 XMP3 series Soft Range Point Name component XP2 XMP2 XP3 XMP3 XP2 XMP2 XP3 XMP3 X Input point X000 X011 octal 10 Output Y Y000 Y007 octal point M0 M2999 Auxiliary O M3000 M7999 relay M8000 M8767 SO S511 Status S512 M1023 TO T99 100ms not accumulation T100 T199 100ms accumulation T200 T299 10ms not accumulation T300 T399 10ms accumulation T400 T499 1ms not accumulation T500 T599 1ms accumulation T600 T618 1ms with interruption precise time T620 T639 vacant C0 C299 16 bits forth counter C300 C318 32 bits forth back counter O C320 C598 32 bits forth back counter Counter O C600 C619 one phase high speed counter O C620 C629 Pulse direction high speed counter O C630 C639 AB phase high speed counter D0 D999 DO D
21. loading If the downloading is completed it will pop up below window mra Ci Download Successfully Attention 1 Do not cut the power when downloading or you have to download again 2 The downloading cable of downloading OP screen is the same as downloading PLC program 3 Do not download when XCPPro and OP software are both opened 38 5 The extension ability of XP XM P 5 1 Extend BD board XP3 XMP3 series product exclude XMP2 32R T E can extend XP3 series BD board via the insertion groove at the back in order to control and measure the analog guantity The specs and type of BD board is as below table BD board type XP3 2AD2PT BD 2 channels analog input 2 channels PT100 temperature measurement XP3 2TC P BD 2 channels K thermocouple temperature measurement PID adjustment inside XP3 2PT2AD1DA BD 2 channels PT100 temperature measurement 2 channels analog input 1 channel analog output BD board specs XP3 2AD2PT BD Analog input DCO 5V 0 10M Input resistor 300k Platinum resistor Pt100 2 line z Temperature measurement 100 350 C range ISO 101555 Digital output range Integrated SE 0 8 of the full scale precision 15msX 4 channels PID output value 0 K4095 Empty load mpty loader 3500 defaulted value 39 Input characteristic p 5 on Temperature 350 T Analogs input 10V 5v No insulation among each channel of PLC OSEM 0 point As it is opera
22. mbers MA 4AD MA 4AD2DA Analog input 4AD Analog output 2DA Analog input range 0 5V 0 10V 0 20mA 4 20mA 0 5V 0 10V 0 20mA 4 20mA Analog output range exterior load exterior load resistor resistor 2K IM less than 500 43 Digital input range prome zi 10 bits binary number 0 1023 Digital output range 12 bits binary number 0 4095 A 1 4095 12Bit 1 1023 10Bit Integrated precision 0 8 20ms 1 channel 3ms 1 channel Power supply for DC24V 10 100mA analog guantity Use M3 screw or fix on the DIN46277 width 35mm rail Profile dimension 63mmx 102mmx73 3mm MA 6TC P Integrated precision 1 C MA 6PT P Digital output range Full scale 4095 12 bits with sign binary 44 MA model connection XP XMP can connect with MA model via RS 485 com port A and B point It can extend 16 MA models via setting DIP switch of MA model Please see the connection figure XINJE o fo apagada alelel lelele
23. n Turn the screen to the last page Turn the screen to the next page Press the key to modify the register value The register which is being m up m7 modified will display in reverse colour and the bit will twinkle If there is no register component in the screen it will do vacancy operation once Before pressing ENT key press SET key again to cancel the setting and continue modifying the next data register To write the modified value in the register and continue modifying next register After the last register in the screen has been modified it will quit the setting Alarming list key After setting the function of alarming list press this key to jump to the alarming list screen LR Clear the selected area when modifying the register data Set the positive or negative of the data when modifying the register data Number key 0 9 press the key to set the number you want n Function key F1 F8 NOTE Besides the function listed in the up table all the keys can be defined as the function of force ON force OFF reverse or momentary ON Please see below picture Open OP software put a button in the screen All the faceplate key presses are displayed in the key menu user can set the function as they need 35 For Series Edit Tool Untitled File Edit Tool Help Ojea eje olele alalal a Screen Description
24. n It can save space with slim outline and improve the convenience of maintenance Product characteristics u Integrate logical control analog quantity in out and HMI into the product On off quantity input 10 points optical coupling insulation On off quantity output 8 points relay output transistor output R amp T mixture output Analog quantity XP XMP can extend BD board to realize analog quantity in out control Easy edit of the HMI picture rich function LCD display 192 x64 pixel 3 7 inch LCD useful life can reach 0 5 million hours 26 function keys can be redefined by user Sensitive and accurate key press Multifunctional download port HMI and PLC use one download cable Waterproof level is IP20 Small structure space saving c cc C cc C Simple and modern outline Type List Relay output Transistor Relay amp Transistor output output XMP1 18R XMP1 18T XMP1 18RT XMP2 18R XMP2 18T XMP2 18RT XMP3 18R XMP3 18T XMP3 18RT Relay Transistor Relay amp Transistor XP2 18R XP2 18T XP2 18RT XP3 18R XP3 18T XP3 18RT Type Name 2000 000 1 1 Name 2 PLC Type 3 In out points 4 Output Type 3 4 XP XMP series 1 XC1 series 2 XC2 series 3 XC3 series 18 Input 10 points output 8 points R Relay output T Transistor output RT Relay amp Transistor output Notice XMP series exclude XMP2 32 series products in this manual About these products please refer to Integral C
25. oduce close sound Resistor 3A load Inductance SOVA load LED load 100W Minimum load DC5V 2mA Response OFF gt ON 10ms time ON gt OFF 10ms Relay output circuit Output points Maximum load Relay output has two common points Different units can drive the loader of different power voltage systems Loop insulation It is electric insulated between relay output point and outside load circuit Action indication Relay output coil produces close sound when it is on Response time The response time is about 10ms transferring the ON or OFF signal from relay output coil to the output connection Output current Output current is 3A per point to drive resistor load for voltage below AC250V Inductor load is below 80VA AC100V or AC200V and light load is below 100W AC100V or AC200V Open leakage current There is no leakage current when output point is OFF it can drive neon light l Use life of relay output point The standard life of inductor load such as contactor solenoid valve according to our experiment results 20VA load is about 3 million times 35VA load is about 1 million times SOVA load is about 0 2 million times However the life will extend 1f parallel connect surge 19 absorber with the load Output connection example To avoi d burni ng PLC basic circuit set a fuse every 4 points 10A HEA AC power Load J suppl y Po i Yo lt A250V Ho ly m Xx
26. ontroller Manual XMP2 32 1 2 Specs General Specs Surrounding Configuration E Specs P 1 ower SUPP Y Dc12V DC24V voltage Power Less than 10W TYP2 0W Power cut j Less than 20ms moment permit Endurable AC1000V 10MA for 1minute between signal voltage and ground Insulated About 10MQ DCSOOV between signal and impedance ground Operati temperature St temperature Environment temperature Endurable guiver 10 25Hz X Y Z direction for 30 minutes Anti jamming Voltage Noise 1000Vp p Air No causticity gas According to IP20 Cooling mode Natural wind Dimension 172 0 121 0 56 5 Panel open aperture 164 0 113 0 dimension Download port RS 232 HMI Specs ten Kelly Blue LCD S SEE 3 7 inch dimension Useful life Over 20000 hours 25 C 24hours operating Display area 192 64 va Regulation resistance available Characteristic Character Chinese English setting Lattice font vector font Matrix or resistance Touch mode Touch unable touch mode 64KB _ Flash ROM Register PLC Specs IKB SRAM XP1 XMP1 XP2 XMP2 XP3 XMP3 Interior coil s points M 8768 8768 E A a 100mS timer Set time 0 1 3276 7 seconds Specs 10mS timer Set time 0 01 327 67 seconds 1mS timer Set time 0 001 32 767 seconds 16 bits counter set value KO 32767 32 bits counter set value 2147483648 2147483647 Data Register DO 288 words 2612 words 9024 words Timer
27. s Del sDel 6 Eli SELI E12 sFI2 s gt mici E 1px A Project RE Project EZ PLCI GL Code E Ladder Id Instruction List Func Block Config Block El Reg Comment Used Stal E Free Monitor El Data Monitor EE Set Reg Init Value a a PLC Config Era Output sa Password a 1 E Serial Port Description Project Row Col SE are si 4 Row 0 Col 0 OVR FLC1 XC3 60 uni cation Com Static Set up a project We take XP3 18R as a example to explain how to set up a project 1 Modify the type Open the software click file change PLC model 28 im ECPPro DEN U Hew project Ctrl H Search View PLC Operate FLE Setting EA i E HE 4p lt gt lt a eT Open project Close Project lA Save Project Ctrlt5 Save Project As PICI Ladder Add PLC Search 485 Network Delete PLC Change PLC Model Import Download File Choose XP3 18 XMP3 18 Select PLC Model E No Connect To PLC PLC Model In Program XC3 60 XP1 XMPlseries choose xC2 48 Input Hum 10 XC2 60 Output Num 8 XP1 18 XMP1 18 XNP2 32 XF2 18 XMP2 18 xC3 xC3 14 LR XP2 XMP2 series choose 1032 XP2 18 XMP2 18 XC3 48 X XS XP3 XMP3 series choose XC5 32 4PLS XC5 60 XP3 18 XMP3 18 S XCM XCM 32 DE Cancel 2 Compile the program For program
28. s the hardware and software of the products As mistakes are unavoidable we couldn t promise all correct However we would check the data in the manual freguently and in the next edition we will correct the necessary information Your recommendation would be highly appreciated SAFE TO NOTICE set hes dat e iaa da a eat A o a iza A coe ea 8 LESUMMARIZATION es no as ad pee a a a A 2 eds 9 1 1 Product summarization a a tt 9 LEA POE ALA A RS bk aja AA A E 11 13 Parts explanada 13 14 Outline CIMENSI ON ices sieecessrcenteessienteeatc URADEN KO entventientessteesles iee Te sede er in EsTe er eiat 15 2 IN OUT SPECS AND EXTERIOR LAYOUT 00 cccccccccescesceseeeeeeseeseeseceeceeeeaeeaeceeeeseeaesseeeeeeaees 17 De VIPUL SPOS creta E OOO bee oe Petes oa ota 17 2 2 Relay output specs and circuit 19 2 3 Transistor output specs and circuit nana 21 3 PLC FUNCTION AND APPLICATION nana 23 3 1 PLE MSU OM as sani vie cod sted dea AO POP PO Ob UVE da 23 3 2 SOM COMPONENE A OT 24 Sed OELUP A NO 28 3 4 communication FUNCTION aoa vota E E E AE E A TaT 31 4 HMI FUNCTION AND APPLICATION 35 4 1 HMI function introduction a A E R E 35 4 2 Build a project ios illinois 36 5 THE EXTENSION ABILITY OF XP XMP nana 39 SS vij e ENE NA ENE ee era ii evi 39 27 EXTENO MA modela is vni Ne deen NA ee A NA a a Ni 42 2 3 SO A TN 45 Thank you for purchasing Xinje XP XMP series integral industrial controller please read the manual befor
29. se check the serial port and the cable Config Software ComPort k Serial Port C Baudrate B COMS 4800BPS 192008PS come O COME 9 SEOOBPS O 384008FS a CONS COMT Parity P coma cons Hone Odd 0 Even Other set Databits 3 Stopbits 1 Communication Error Check DE Cancel 2 Download the program After connecting successfully click to download the PLC program If the PLC is running it will pop up the stop running window click OK to continue downloading 30 Downloading Program Compiling Downloading Program Downloading Se After downloading click Bl to run the PLC program 3 Upload the program If you want to check the PLC program in XP XMP click E to upload the program to the PC Then click Hl to save the program Uploading Program Upload Succeeded 3 4 communication function XP XMP series support Modbus and free format communication protocol The instructions please refer to XC Series PLC Operating Manual paragraph 6 4 1 and 6 4 2 Communication port XP XMP series product have program port DB9 pins port and RS 485 com port A B point Program port can only be used to download PLC program and HMI pictures However RS 485 port can be used to communicate with other devices RS 485 port can be connected with varied devices the communication parameters baud rate data bit etc
30. t below is focus on XP XMP series products only Please safekeeping the manual put in somewhere easy to get and read and give the manual to final user e Notice items ATTENTION O Do not put the wire close to cable keep 10cm distance at least O Do not change the inside module of product or it may cause fault error action loss fire O When it smelly or noisy cut the power immediately short tweet after power on is normal O Do not press the screen with pen screwdriver or other sharp tools it may cause screen break or error O For installing the product tighten the screws to avoid loosing Transport install store assemble and maintain the product accurately to avoid breaking DANGEROUSNESS Confirm the power voltage and wire connection before turn on the power in order to avoid breaking Do not touch the connection point to avoid getting an electric shock Do not open the back cover board Cut all the power before installation and take down to avoid error and fault Please use in the surrounding the manual stated to avoid accident Do not use the product under the condition of high frequency radiation strong magnetic field to avoid interference 1 Summarization 1 1 Product summarization XP XMP 18 series integral industrial controller integrated human machine interface HMI and PLC XC1 XC2 XC3 series It can instead of HMI and PLC to fulfill the control functio
31. ted via data register it is not restricted by master oin p PLC s standard max control points XP3 2TC P BD Conte Temperature 0 C 970 C DC24V 10 50mA XP3 2PT2ADIDA BD Analog input DCO 5V 0 10V input Platinum resistor Ptl00 2 signal resistor 300k0 lines format Digital input A O 10 bits binary 0 1023 range Analog output O oQ 20mA 4 20mA range Temperature measurement O 100 350 C range Distinguish rate Digital output 0 16383 1000 3500 lo 40 range oo IS E Integrated SR 0 8 of the full scale precision Convert time 15ms X 4 channels PID output 0 K4095 Empty load m Mma 0 3500 defaulted value ki f ee SS analog output ma digital output Z characteristics dmi analog sapi 10 Sw digital input insulation There is no insulation among each channel of PLC VO point 0 point As it is operated via data register it is not restricted by master PLC s standard oin max control points Installation position of BD board The installation position of BD board on XP3 XMP3 is as below MODED XP3 18R SNg 20060502118 DATE 20060510 Install here 0000000000000 000000080 2W V A COMO YO Yi Y2 Y3 COMIY4 Y5 YG Y7 COM XO X1 X2 X3 X4 X5 X6 X7 X10X11 PEFR y OO A A E A NA E A E NONE NON Oo 0 6 00000000000 00000000000