Home
An Introduction to Automatic Sliding Doors
Contents
1. BP2 1 Photo Cells Active Infrared Safety Beam Controller and Automatic Door Safety Sign A Selection of safety signs are Single set of beams Intelligent safety beam sensor designed to fit t required to comply with the current British standards BS7036 he slimmest of door profiles with a detection range of up to 12m Increased Pedestrian Safety Single or double set of infrared Automatic safety beams in the door close zone prevent door closure when the No entry light beam is broken Door Keep Clear Clear Large Detection Range Detection range of up to 12m Fire Alarm Links Depending on your fire officer s requirements the door may be required to close or open in the event of a fire Dedicated fire alarm contacts are available with in most automatic door operators These are volt free normally open and will be connected to the fire alarm panel by others such as a credited fire alarm company BP2 2 Photo Cells Active Infrared Safety Beam Controller and Dual set of beams Active Infrared Safety Beam Controller and Dual set of beams Simple to Install Automatic sensitivity adjustment and recognition of a single or double set of safety beams simplify installation Extremely Reliable Excellent resistance to the negative effects of sunlight and artificial light Telephone 0845 643 0013 e www global automatics com Weather Covers and Ceiling Kits htto www global automatics com shop sensors sensor
2. GLOBAL AUTOMATICS m 1 ET nn En es An Introduction to Automatic Sliding Doors Telephone 0845 643 0013 www global automatics com Ot ON er eI NM N PWN P P N kk ak ek ek ek eck CO GU POW OAT Oy OA ON Ore Cover Page Contents Slide Door Operator Explained Activation Safety and other Accessories Sensor activation and Safety Photo Cell Fire Alarm and Signage Weather Covers and Geiling kits Push Button Activation Control Switches More Accessories Typical Door Set up Example Premier Slide 100 Premier Slide 100 continued Premier Slide 100 Operator Extrusion Premier Slide 100 Control Panel Premier Slide 100 Operator Motor Premier Slide 100 Integrated Motor Lock Premier Slide 100 Battery Back up Premier Slide 100 Floor Guides Premier Slide 100 Floor Guide Drawings Premier Slide 100 Retro Fit Kit Explained Premier Slide100 Technical info Premier Telescopic 134 Premier Telescopic 134 Continued Premier Telescopic 134 Drawings Contents 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Premier Telescopic 134 Extrusion Premier Telescopic 134 Floor Guide Premier Telescopic 134 Technical info Useful Info Safety Barriers amp Pocket Screens Part 1 Safety Barriers amp Pocket Screens Part 2 Safety Zones Break Out Doors Drawings part 1 Break Out Doors Drawings part 27 Powder Coating Glass Door Solutions Door Weights New Enquiries D
3. www global automatics com shop sliding door operators sliding door accessories cat 19 html Floor Guide An adjustable nylon Floor guide on a fixed steel plate Distance between fixed frame and base of door runner required clearance between door and frame 6 5mm suitable for most sliding door applications The standard floor guide system available with the Premier Slide uses a guide track installed into the bottom of the door rail and a floor mounted adjustable guide The guide channel is simply cut to the inside dimension of the door Leaf and attached using countersunk self tapping screws straight into the door rail The rear of the door can be notched out to allow the guide block to slide in if required Floor Guide Channel An ar anodised aluminium channel to suit our standard floor we guides Fixes upward into the bottom on a sliding door 2 L Telephone 0845 643 0013 19 www global automatics com Premier slide 100 Sliding Door Single Set Tunnel Fix Fit Operator 20mm above underside of Transom Bar Clear Opening S O x 1 2 142mm Section AA Premier slide 100 Sliding Door Double Set Tunnel Fix Clear Opening S O x 1 2 194mm A lt Door Leaves Closed Telephone 0845 643 0013 20 www global automatics com Retro Fit Sliding Operator htto www global automatics com shop retrofit kits cat_1 html R
4. 600mm Sec Partial Opening Adjustable 50 80 of Opening Width Aux Power Supply 24v dc 2amp Ambient Temp 15 c to 50 c Minimum Door Width 500mm Telephone 0845 643 0013 www global automatics com 22 h t Premier lelescopic1 34 to www global automatics com shop sliding door operators telescopic sliding operators cat 21 bim Telephone 0845 643 0013 www global automatics com 23 The Premier Telescopic 134 Premier Telescopic 134 The Premier Slide Telescopic allows the building designer to create a wider clear opening compared to a standard sliding door The premier slide provides power safety and reliability in a heavy duty automatic door The robust construction and precise microprocessor technology make this sliding operator the premier choice for automatic sliding door solutions The versatility of the premier slide integrates beautifully with today s modern building designs linking effortlessly with access control firearms and Control systems The premier Slide Telescopic provides the most comprehensive range of features that could be required in an automatic door operator Product features ebe Telescopic allows for a clear opening of up to 60 of your overall aperture size depending on the framework type The aluminium sliding door track is only 113mm wide making this one of the most versatile automatic telescopic sliding door systems available Available in 2 wing and 4 wing configurati
5. accessories cat 25 html HR 100 Ceiling Kit A ceiling mounting kit HR 94 Ceiling Kit Suitable for a HR100 A ceiling mounting kit Suitable for a HR94 Domino Weather Ceiling Kit A dual Purpose Flush Mounting Kit HR 100 Rain cover and Surface mounting ceiling kit for the Domino Ceiling kit sensor Telephone 0845 643 0013 www global automatics com Push Button Activation http www global automatics com shop press pads cat 14 html Push Button Activates the door operator to open the door when a user presses the button e Hardwired Push Button Push button activation for an automatic door hardwired into operator to the activation switch Push button Microwave sensor Hardwired stainless steel switch Also known as a push button or push pad with ABS back box wheelchair logo and Push to Open text printed Wireless Push Button Wireless stainless steel switch with ABS back box Transmitter included and an Ultra small 433MHz receiver will be required for the wireless push button to work with an Automatic door operator for the wireless push buttons to work with Wheelchair logo and Push to Open text printed Our hardwired and wireless push pads come with the Wheel chair logo and Press to open text in three sizes 115mm x 115mm x 44mm 152mm x 152mm x 44mm and slim line 38mm x 115mm x 44mm Telephone 0845 643 0013 www global automatics com Control Switches http www global automatics com shop sl
6. an existing door are operator covers fitting plates operator arms packer bars and safety barriers Telephone 0845 643 0013 RAL Colours RAL is a colour matching system used in the UK RAL refers to the RAL CLASSIC system mainly used for varnish and powder coating There are a wide range of RAL colours available but please keep in mind that non standard colours may be more costly to source so please check these with your powder coating company prior to install Paint Care Although Powder coating is a long life finish of up to 25 Years care should be taken when handling products that have been finished Sharp edges can scratch and Piece Powder coated surface Powder coating should be cleaned down with warm water and a mild detergent Do not sue any strong cleaning chemicals as it may affect the paint 35 www global automatics com sliding Glass Door Solution This is an example of fixing sections solutions available from others for glass sliding doors e Solution 1 HA EN Q 10 mm 2 75 v D BB mm 3 46 Solution 2 0 0 22 mm 0 86 K a Q Q Ae WEIGHT OF GLASS 119PM611 2 5 Kg x 1 m x 1 mm thick in the items 1 67 bx 10 76 f x 0 039 in thick OOTMA7370 001MA7470 001MA75 0 20 001MA7353 001MA7453 001 MA7553 Es E Cp es We E e o Solution 1 Solution 2 001MAM612 in the items Le Height from floor for fixing the profile to the beam Height from floor of lintel O01 MAT253 OOTMA
7. considerably lessen annual heating and cooling costs Diagnostics Some automatic systems have self diagnostics This means faults and necessary repairs can be quickly identified Down time of your door is therefore kept to a minimum Information Systems can be introduced to count frequency of operations This allows the customer to calculate busy trading periods and or the number of visitors through the door set Advertising space Often door systems are made of slim aluminium sections with vast areas of glass This can be used as an additional advertising space for your business Fused Spur FUSED SPUR IMPORTANT Always Inform the customer that they must provide a 13A 240 Volt power supply terminated in a switched fused spur within 1000mm 1 meter of the operator This must be installed and working prior to our installation date A local electrician will easily install a fused spur quickly and with minimal cost or fuss Floor Levels New Framework Installs Floor Levels It is important to measure the floor levels inside and Threshold Relevant when surveying for a new prefabricated outside This can be achieved taking height measurements from door a threshold is normally an aluminium strip that is used when various points inside and outside the building when surveying for the internal and external floor surfaces meet and can be used in the installation of new prefabricated doors conjunction with a brush strip to create a weathe
8. same plane as the doorway opening e A Pocket screen of minimum height 1500mm measured from finished floor level so that a pocket is formed into which the door slides e Presence sensors protecting the area through which the doors travel during their opening cycle DS that e doors if activated opening at search speed or give an audible warning when traffic is detected NOTE Barriers and Screens are not suitable for use with telescopic sliding doors as they introduce serious trapping hazards A j ILA CT IMA L e em ii Je AAST H roe LSA YI VVV W E O b a l a ULOMAaLICS COM Safety Barrier and Pocket Screens Safety Barrier nd 25 D Side screen mn ge 4 we Sliding door SEE os Sala 3 Oy d Ga ee 25 min EE e me Barrier Dimensions in millimetres Figure 1 Example of barrier rail aluminium Infill Panel Kit Form Telephone 0845 643 0013 Pocket Screen Fixed screen Sliding door Se Pocket screen 25 en a Dimensions in millimetres Figure 3 Example of a fixed screen forming a pocket Our Barriers are built to order from our bespoke aluminium section They are dry glazed Using Gasket and stand 900mm high Each barrier is constructed with a large supporting rail and cleat system to withstand the pressures put on them during their life Available with Glass or an Our floor to floor barrier has two substantial solid Flat feet for secu
9. 7453 001MA7 553 v Height of glass with S20 profiles A3 Height of framed leaf with S40 profiles Telephone 0845 643 0013 e 36 www global automatics com Door Weight Here is an approximate Graph to help you calculate the door weight Please bear in mind that this table is for guidance only it assumes that the door is made of typical 3mm wall aluminium without a midrail Wooden steel and other types of door should be assessed individually You will need to Times the Door Height by the Door width to get an overall area to use the table below LE 1 1mtr wide door x 2 2m High door 2 42 Overall area meters On our Example a 2 42 area door with 6 4mm Laminated glass would be approximately 44Kg in Weight Please use this table for Guidance only for an exact door weight you will have to weigh the Individual Doors Door leaf weight kg Example Telephone 0845 643 0013 www global automatics com 8 24 8 glass 6 10 6 glass 8 mm glass 6 mm glass Door leaf area m7 12 mm glass 10 mm glass 37 How To Deal With An New Enquiry keng The questions on the Sliding door enquiry Sheet will help you identify any potential issues and select the appropriate equipment for an in principle quotation Telephone 0845 643 0013 38 www global automatics com Dealing With A New Enquiry Every automatic door installation is different so to establish exactly what is required you mu
10. ETRO FIT KIT A retro fit kit can normally be install into the canopy of an existing old sliding door operator when the operator is no longer working This can be a cost effective way of replacing old or worn out equipment To establish what the old operator is we require its make and model If this is not possible we can normally Establish the operator type from photographs of the motor and processor units Global Automatics have the Biggest range of Retrofit Kits available to the Market Each kit is bespoke to the Operating equipment it is replacing Our Kits normally require no drilling and take just a few short hours to install Telephone 0845 643 0013 Each Retrofit Kit contains 1 x Original Dunker Motor With Electric Lock 1 x Control Unit amp Battery Back Up System 1 x Mode Switch 1 x 5mtr Length of Belt 1 x kit of Brackets to suit the operator 1 x Installation Manual 1 x Customer User Manual Some of the Operators that we offer kits for are built on Bolt up modules It is for this reason that we supply the Module with all our equipment pre mounted so you just have to bolt it in the same place as the old equipment 21 www global automatics com Premier Slide 100 Premier Slide Retrofit Kit Single Door Double Door Max Door Width 2000mm 3000mm Max Door Height 3000mm 3000mm Max Door Weigh 120kgs 200kgs Mains Voltage 100v 250v AC Hold Open time 0 60 secs Opening Speed Max 600mm Sec Closing Speed Max
11. be not greater than 220 N at the leading or meeting stile Where a break out facility is fitted to a glazed door it is essential that the glazing meets the break out resistance without shattering nan en wm wm ee ae eee eee em ae mA A FA VA MAA ta A A d L CL fi J IA H b Break out internal doors only gebeten c Partial break out external doors only Figure 7 Break out sliding doors and screens Telephone 0845 643 0013 www global automatics com 34 Powder Coating What is Powder Coating Powder coating is a type of coating that is applied as a free flowing dry powder The main difference between a conventional liquid paint and a powder coating is that the powder coating does not require a solvent to keep the binder and filler parts in a liquid suspension form The coating is typically Applied electrostatically and is then cured under heat to allow it to flow and form a skin The powder may be a thermoplastic or a thermoset polymer It is usually used to create a hard finish that is tougher than conventional paint Powder coating is mainly used for coating of metal such as aluminium extrusions Powder Coating and Automatic Doors Powder coating is an important part of the door automation industry It ls used on newly prefabricated doors shop fronts and helping new equipment blend in with existing aesthetics The main swing door items that may require powder coating when fitting on
12. d Canopy mounting options Interlock for security lobby systems eMonitored safety sensor inputs Dedicated plugs for each sensor eEasy adjustments via the Access Panel Telephone 0845 643 0013 e 13 www global automatics com Premier Slide 100 Extrusion A minimum transom height of 100mm is required for to fit the Premier Slide 100 Operator Extrusion 165mm S0mm 100mm Tele phone mr UT JJ LJ VV VV VV amp U b ad l a UTOMAalLICS COM _ Premier Slide 100 Control Unit Mains in kettle plug Battery fuse Wiring information Wiring block cover Motor connection plug Mains fuse On off switch Power and status led s Dedicated Sensor Connections ICM MMO W gt Telephone 0845 643 0013 e 15 www global automatics com Premier Slide 100 Motor A Gearbox 15 1 ratio B Motor 24v C Motor brake lock D Encoder Telephone 0845 643 0013 16 www global automatics com Integrated Motor Lock The Premier Slide 100 Electric Lock is built into the Motor Gearbox for easy installation It has 150Nem of Torque when braking so is very strong Our active control unit will also increase the holding force if it sees that the doors are trying to be forced open Our lock is Fail Safe but will remain locked upon power cut due to the Monitored Battery Backup Telephone 0845 643 0013 17 www global automatics com _ Premier Slide 100 Battery Backup The Prem
13. e Control This is normally installed in an automatic door operator when a wireless push button is to be used as activation it receives the signal from the transmitter in the push button telling the door operator to open Telephone 0845 643 0013 10 www global automatics com Typical Door Setup Example Dual Activation amp Weba Premier Slide 100 i n a yo Side Screen Safety Sensor Side Screen Safety Sensor gege i FR T ser i r L 4 gt e NM K e DE H e P g be 5 E l gg R 7 ge Le Pa Es E a TT Nn D D K gt L R 4 wen NS NW e d ff En A RE safety Signage EAR mmm EE eg Telephone 0845 643 0013 11 www global automatics com Premier Slide 100 VOER COMPANY LOGO HERE Automatic Mode Telephone 0845 643 0013 www global automatics com 12 Premier Slide 100 http www global automatics com shop sliding door operators premier slide operators cat 18 html Main Features Self diagnostic system Only 100mm in Height Easy to adjust wheel systems Creep Speed input Electromagnetic motor lock as standard Fast Installation minimal tools required Monitored battery backup with optional opening Switch able Motor direction Full microprocessor control with smooth motor control using encoder technology Slim line mode switch available in Surface flush fit an
14. e door has a mid rail between 500mm and 800mm then 1150mm and 1500mm from the floor must be visible Manual controls push pads etc must be between 750mm and 1000mm from floor level and set back 1400mm from the leading edge of the door when fully open Manifestation Clearly defined with manifestation on the glass at 2 x levels 850 to 1000mm and 1400 to 1600mm contrasting with the glass from both sides and in all lighting conditions 47 www global automatics com Notes Disclaimer All Pictures and Wording in this document remains the property of Global Automatics Ltd All information is based on the opinion of the writer and does not constitute the company view This collection of information has been collated as a help guide and should not be used as a sole source when researching automatic doors All information should be taken as an opinion not as fact as you should consult the relevant governing bodies before using this information for specifying estimating Global Automatics cannot be held responsible for any errors in this document and reserve the right to make amendments where deemed necessary For more information on the BS7036 1996 please go to www bsigroup co uk where you can purchase a full copy of this British standard or the Automatic door suppliers association www adsa org uk Telephone 0845 643 0013 www global automatics com
15. ealing With A New Enquiry Sliding Door Enquiry Part 1 Sliding Door Enquiry Part 2 Site survey Slide Door Drawing Selling Automatic Doors Fused Spur Floor Levels Building Regs Part M Notes Slide Door Operator B eg p5 lt lt ae ee ed ge N vee EZ ZS DE mm rap Lei A Sliding Door Operator is a device that operates A End Plate a sliding door for pedestrian use It opens the door MO l A C Control Unit automatically waits then closes it Typically used D Motor Wheel On the entrance doors of large retail businesses E pai Smaller retail businesses prefer Automatics Swing F Top Rail Adaptor Doors G Idler Wheel Telephone 0845 643 0013 www global automatics com GLOBAL AUTOMATICS Automatic Sliding Door Activation Safety and Other Accessories Telephone 0845 643 0013 www global automatics com Sensor Activation amp Safety htto www global automatics com shop sensors sensors cat 26 html Activation Sensor Sometimes referred to as a PIR or Radar opens the door when a user approaches it Presence Safety Sensor Detects obstructions and stops the door opening or closing if there is a pedestrian in the way HR100 2 Double Relay A dual Sensor Suitable for Sliding doors Combines Activation and Presence Dual Relay Output Separate adjustment of activation and safety detection zones possible Two Sensors in One Guarantee optimum door usage efficienc
16. ht Width Fixed Side Screens Give measurements in mm Height Width Fanlight Gisss above the door Gwe measurements in mm Height Width Door application Domestic Commercial Telephone 0845 643 0013 www global automatics com 40 Is there any existing system to be interfaced with operator Please give details of Access Control fire alarm warden call etc Activation Please describe how the door is to be activated eg Activation sensor push buttons remote control etc If retro fit how would you describe the condition of the door This is to establish if the door will require attention prior to Installation What is the doors function Internal external corridor toilet Goor fire Goor etc Fused Spur Always Inform the customer that they must provide a 13A 240Volt power supply terminated in a switched fused spur within 1000mm 1 meter of the operator This must be installed and working prior to our installation date A loca electrician will easily install a fused spur quickly and with minimal cost or fuss Additional Information Please give other info relevant to the door not provided above Telephone 0845 643 0013 www global automatics com 41 site Survey ER T E ad j 4 To establish exactly what equipment is required to automate a set of doors a site survey may be required Telephone 0845 643 0013 42 www global automatics com Slide Door Drawing When you have taken a
17. iding door operators sliding door accessories cat 19 html Morning Entry Keyswitch A momentary switch Mounted and Canopy commonly used for the first point of entry on an automatic Mounted Switches von Ca door The keyswitch gives out a single impulse for one LOGO HERE entry Acts as a switch for customers to Automatic Mods change the door s function engineers mode allows for easy adjustments and set up faults diagnostics with issues displayed on screen uploaded with your logo and telephone number screen saver and auto lock functions to prevent unauthorised usage Surface mounted Flush Customer Modes Automatic Premier Slide 100 Keyswitch The Premier Slide 100 Keyswitch has 4 Exit Only Positions This keyswitch can be Enter Only used In line with any of our Access e Hold Open switches for a secure change of Door operating Mode Automatic Partial Opening Closed One Way and Hold Open e Closed Pharmacy Mode Auto Width Telephone 0845 643 0013 www global automatics com More Accessories Access control the door opens when an Access Remote Control Remote control transmitter Control System determines the user is authorized sends a signal to the operator to open the door to go through This incorporates magnetic locking Works with Ultra Small Receiver 433MHz RX keypad and key fob entry systems Ultra small 433MHz receiver is used with Wireless push button or Remot
18. ier Slide 100 s battery Backup system uses two x 12v 0 8ah sealed lead acid Type batteries These are held firmly in place by the battery strap and have dedicated plugs on the Right hand side of the PSU Please remember to isolate the mains via the Kettle plug before removing or connecting the Batteries Our Battery backup system provides a constant variable charge when the door is not is operation depending on the condition of the batteries l e If the batteries are new our system uses a trickle charge for older batteries it assesses the require voltage and charges accordingly The Batteries are constantly monitored Approx checked every 5 seconds to confirm that they have enough power in them to carry out their emergency power failure procedure BS7036 States Operation upon mains power interruption Sliding doors A monitored back up system should be provided for use in case of mains power interruption The monitoring system for the supervision of stored energy within the back up system should ensure that the energy level stored is enough for at least one opening or closing operation This check should be carried out immediately after mains power connection and then at least once every 4 hours If this check is not carried out or the result of the check is negative then the powered door should adopt a predetermined safe position Telephone 0845 643 0013 e 18 www global automatics com Floor Guides and Channels http
19. imes a day and last for several years without any trouble Free In most circumstances a UK based business will purchase an automatic door to the sum of several thousand pounds This purchase can be a capital allowance and your accountant can depreciate it over several years This often equates to the actual cost of the system being negligible Please consult your accountant for exact rules and allowance Cost effective Automatic doors practically pay for themselves when you consider the energy saving on the building s heating and the increased image and convenience factors for your customers DDA compliance Automatic doors allow unhindered access for all your customers without persecution no matter their mobility Work with professionals Automatic door systems are quite complicated and any company wanting to install them must go through a vigorous training program and ideally join the Automatic Door Suppliers Association Choice There are several different types of automatic door swing doors sliding doors folding doors balanced doors revolving doors and low energy swing doors This means that there is always a solution available to solve your access issues Security A wide range of locking solutions are available within automatic doors Features such as timers and controlled access mean you Can open or close your building without even being present Energy Efficient Automatic doors effectively reduce wasted energy and often
20. ll of the details for a new sliding door draw an estimated plan to send to an aluminium prefabricator This is what they will require to supply a quote for the prefabrication of the door side panels and Installation What to measure for new set of Sliding Doors Height Min 100mm Transom sliding Doors Fixed Side Fixed Side Panel Panel Width Width Min 500mm Width Min 500mm Width Telephone 0845 643 0013 43 www global automatics com Selling Automatic Doors Here are some of the main reasons people buy automatic doors that will help you identify a sales need Safety With today s modern sensors and the BS7036 1996 safety standards automatic doors are incredibly safe Fail safe devices and procedure mean accidents are rare Customers prefer automatic doors Research proves that consumers prefer automatic doors and expect to see them at hospitals airports hotels motels shopping centre entrances and retail stores Aesthetics Automatic doors come in a wide range of finishes from stainless to powder coating A well designed entrance can add significance to your business Convenience Automatic doors enable easy access for all and instantly demonstrate to users that the establishment cares about their visitors Your image Automatic doors are impressive and give your building a certain status Low maintenance Automatic doors are extremely reliable They are often operated thousands of t
21. nds minimum If further movement of traffic occurs and the traffic remains within the detection zone then the door should remain open for an additional 30 seconds ee a i ee SE ee mg i TULA ddd LELEL LLLA Nik a em NOTE Shape of field is shown as an approximation and should be taken as indicative only Dimensions in millimetres Figure 6 Dimensions of presence sensor threshold monitoring field mn _ _ mg e Telephone 0845 643 0013 32 www global automatics com Breakout Sliding Doors and Screens Means of Escape If powered sliding or folding door s are proposed for installation on an escape route and are intended as means of escape door then the doors should be capable of manual break out in the direction of escape Alternatively and more commonly the doors should be linked to an automatic fire detection system that opens the doors on activation of the fire detection system or failure of the power supply NOTE If neither of these recommendations can be achieved or if they conflict with fire and building control authorities then powered sliding or folding doors may not be appropriate for means of escape and suitable alternative installations should be considered Break Out It is essential that powered operation ceases immediately upon break out occurring where the door or screen is fitted with such a facility The resistance to break out should
22. on eHighly reliable 18 months warranty Designed for easy installation repair and servicing Highly precise microprocessor driven control unit with optimum adjustments eInterlock function for secured access doors Self setup system and monitored battery backup in accordance with BS7036 1996 Canopy stay to hold up the canopy for easy installation and maintenance Designed and manufactured in the UK Telescopic Door Single Set Tunnel Fix Clear Opening S O x 0 666 239mm Door Leaves Closed Fy F a n WA Ae LAN JNA E KAKA SW AN Wi VARA AV AVAVA A AZAS Y NDT AOS SO x KS Af d d d KZ NN Section AA Telescopic Door Double Set Tunnel Fix Clear Opening 1 Frame width 90mm 3 A 2 FRAME SIZE 388mm A Clear Opening Door Leaves Closed AS Telephone 0845 643 0013 www global automatics com 25 The Premier Telescopic 134 Extrusion A minimum transom height of 134mm is required for to fit the Premier Telescopic 134 Operator 134mm Telephone 0845 643 0013 26 www global automatics com Telescopic Door Mulllon Floor guide Floor gulde flxed inside of frame Frame Sectional Plan Veiw Frame Fitting Plate Floor gulde Floor guide positioning Premier Telescopic Doors Floor Guide Frame Fitting Plate Cut out for Floor guide Fitting Plate V S A WX VONG ply Section through Doors open G IE Telescoplc Doo
23. r Frame Floor gulde Frame Cut Out Telephone 0845 643 0013 www global automatics com Fitting Plate Fitting Plate Section through Door Telescoplc Door Floor guide Floor gulde fixed to inside of Telescopic Door Mullion Telescopic Door Mulllon 2 Premier Slide Telescopic Single Door Double Door Max Door Width 1800mm 3000mm Max Door Height 2800mm 2800mm Max Door Weigh 120kgs 200kgs Mains Voltage 100v 250 v AC Hold Open time 0 60 Sec Opening Speed Max 400mm Sec Closing Speed Max 400mm Sec Partial Opening Adjustable 50 80 of opening width Aux Power Supply 24v dc 2amp Ambient Temp 15 oc to 50 c Telephone 0845 643 0013 28 www global automatics com Useful Information Telephone 0845 643 0013 www global automatics com safety Sensors Barriers and Pocket Screens http www global automatics com shop barriers floor to floor sliding door cat 37 html Provision should be made to deter persons from occupying the area through which the door travels during its opening cycle such as Presence Detection Safety Barrier or a Pocket Screen Pocket Screen The Function of a pocket screen is to provide a single continuous construction installed to safeguard against entering the path of a sliding door during its opening cycle Where Practicable one of the following should be fitted e Barriers Should be a minimum of 900mm in height Normally barriers should be placed in the
24. r seal This is important so that the difference in floor height can be accommodated when a doors is being prefabricated B Existing Door A threshold must not create a tripping hazard and under Part M must not be greater that 15mm in height Threshold Section Examples KAS88 KAS 18 Inner Floor Level Outer Floor Level BT wegen SAP KAS19 Telephone 0845 643 0013 46 www global automatics com Part M Quick Help Sheet Part M is the relevant sections of the building regulations document relating to access to dwellings and other buildings Please note The building Reg Part M is a very large regulation and this page is just an example of some parts that will be relevant to you Please consult the relevant standard for full Info No threshold is preferred but where necessary external doors Less than 15mm That there is a 1500 x 1500mm level landing clear of any door swings immediately in front of any entrance and is of a material that does not impede the movement of a wheel chair CLEAR OPENINGS New Existing Direction and width of approach Buildings Buildings Straight on 800 750 At right angle with an access route 800 750 at least 1500mm At right angle with an access route 825 775 8 at least 1200mm External doors to be used by the general public Telephone 0845 643 0013 Visibility Requirements If completely glazed between 500mm and 1500mm from the floor must be visible If th
25. re fastening to the ground surface This Barrier Allows 6mm clear gap between the floor and bottom of the barrier in accordance with BS7036 1996 Our Automatic door barriers are available Built ready to install or in 31 www global automatics com Safety Zones BS7036 Part 1 Presence sensing active safety devices NOTE There are various types of presence sensing safety devices which may be fitted in various positions at powered doors These devices include active infa red capacitive ultrasonic or photo electric types Devices of this type should be used to detect the presence of slow moving or stationary traffic in the path of the door These devices should be arranged to prevent further motion of a door to ensure that the door does not make contact with traffic in its path It should be noted that different presence sensing devices have different capabilities e g photo electric devices may not detect walking aids whilst others may be less effective in detecting dark coloured objects or young children Specialist technical advice e g manufacture or supplier should always be sought in the selection of presence sensing devices Detection Zone Verification Detection by a presence sensing device should occur when traffic is in the detection zone Detection by a motion sensing device should occur when traffic is moving at least 150mm s on entry into the detection zone Presence sensors should detect stationary traffic for 30 seco
26. st establish exactly what the customer requires Ask the customer how they want the door to operate It is of the utmost Importance that you establish exactly what functions The clients require from the doors so that you can quote appropriately Always ask the customer what they want to achieve from their door Automation and this should give you the information to pick the appropriate activation and accessories Always ask questions and offer all of the potential activation options available as there may be things such as a 4 position key Switch that the customers were not aware if All too often return site visits are made because simple customer requirements have not been established through simple questioning It only takes seconds to ask a question and it costs Nothing A site revisits can cost you valuable time and money Use The New Enquiry Questions Using the Swing Door Enquiry sheet is extremely important for you to establish what the client needs and to avoid any potential future problems with installation and equipment Telephone 0845 643 0013 www global automatics com Sliding Door New Enquiry Survey Sheet Site Details ain contact name andline telephone number obile telephone number mail Single or Double Sliding Door L Address PostCode Single Double Total Size Of Aperture Please give measurements in mm Height Width Sliding Door Leaf or Leafs Give measurements in mm Heig
27. y through separate adjustment of door activation and pedestrian safety Detection zones Timely Door Opening Guarantee immediate detection of fast moving traffic up to a detection distance of 2m from the door face Installation height of 2 2m Safety Beam Installation Optional Eliminate the requirement for safety beams through separate relay outputs for activation and Ssafety2 Depending on door type and national regulations in force Improved Pedestrian Safety Enhance safety in front of the door close area with a focused 24 spot infrared safety curtain Telephone 0845 643 0013 Single Row Presence Sensor Ideally used for sidescreen safety or threshold presence detection This Stops the door opening or closing if there is a pedestrian in the way Sliding Door Side Screen Pedestrian Safety Protect pedestrians from the dangerous leading door edge during door open cycles with a dense curtain of infrared safety Door Threshold Pedestrian Safety Safeguard pedestrians from hazardous door closures due to a shallow but wide infrared safety curtain Solid amp Reliable Avoid the risk of loss or damage to individual sensor parts through a one piece sensor body construction Simple to Install Install with ease without the need for a remote control thanks to comprehensive instructions printed on the sensor body www global automatics com Photo Cell Signage Fire Alarms htt wet lobal automatics com shop signage cat 39 html
Download Pdf Manuals
Related Search
Related Contents
Information - Centre hospitalier de Fontainebleau Toshiba BDX2150KU Blu-ray Player User Manual GE Criterion Renewal Parts Samsung Samsung S5610 Инструкция по использованию GE 131-10595-2 1-07 JR Music Mixer User Manual KS600E/KS700PEK Kicker 2005 CompVR Sub Box Owner's Manual Transfert juridique Manuel de référence Copyright © All rights reserved.
Failed to retrieve file