Home

- Divelbiss Corporation

image

Contents

1. SI APPMOD Tachometer SOLVES IT TACHOMETER APPLICATION MODULE Revision 0 for Software Version 1 0 0 0 PLC on a Chip Patent 7 299 099 A larger format of this manual may be found at http www divelbiss com E 9778 Mt Gilead Rd Fredericktown OH 43019 Toll Free 1 800 245 2327 Web http www divelbiss com Smart Parts for Managing Automation Email sales divelbiss com 2008012 0 TABLE OF CONTENTS Table of Contents Page 1 Package Contents Page 1 Getting Started Page 2 How to Use this Manual Page 2 SI APPMOD Tachometer Basics Page 3 Get to Know the Module Page 3 Module Mounting Page 4 Module Input Power Page 4 Module Operation Page 5 User Interface Page 5 Tachometer Pulse Input Connection Page 6 Output Connections Page 6 Viewing Current Setpoint Values Page 7 Changing Output Setpoints Page 7 Expandability Customization Page 8 Programmed from Factory Specifications Page 8 WARNING The SI APPMOD TACHOMETER as with programmable con trollers must not be used alone in applications which would be hazardous to personnel in the event of failure of this device Precautions must be taken by the user to provide mechanical and or electrical safeguards external to this device This device is NOT APPROVED for domestic or human medical use PACKAGE CONTENTS Whats Included Qty Description Part Number Location 1 SI 200 with Software Pre loaded SI 200 In Box 1 SI APPMOD TACHOMETER Manual 2008012 X In Box 1 Di
2. DEVICE DC POWER EARTH COMMON GND CHANNEL 2 OUTPUT r ges 12 13 14 CHANNEL 1 OUTPUT Programming Setpoint Variable Display LOAD DEVICE Port rs Output Voltage will be equal to Input Voltage on Pin 9 Figure 2 5 Typical Output Connections VIEWING CURRENT SETPOINT VALUES The current RPM setpoint for each output can be viewed on the display As a default on power up the actual RPM input is displayed Press the B1 button to view the first output setpoint 11 will be on steady Press B1 again to view the sec ond output setpoint 12 will be on steady Press B1 again to view the third output setpoint 13 will be on steady Press B1 again to view the fourth output setpoint 14 will be on steady Pressing B1 again will display the current RPM value once again CHANGING OUTPUT SETPOINTS To change a channel setpoint press B1 repeatedly until the channel setpoint is displayed See the above section Once displayed press the B2 button The setpoint will increase by 1 and the indicator for the setpoint viewed will flash indicating that it is being edited For each press of B2 the RPM setpoint will increment by one If B2 is pressed and held after a short delay the setpoint will increment by tens then hundreds and by thousands with a short delay between them The RPM setpoints can be 0 9999 The setpoint will reset to 0 when it is larger than 9999 To exit after changing a setpoint press the
3. Divelbiss The part or component is only to be returned to Divelbiss with a Returned Material Authorization number issued by the Divelbiss Service Department Any warranty service consisting of time travel and expenses related to such services performed other than at Divelbiss Corporation plant shall be at Buyer s expense Warranty of repaired or replacment products will be limited to ninety 90 days or the remainder of the original warranty whichever is greater Warranty is available only if Divelbiss Corporation is promptly notified in writing upon discovery of any alleged defect and examination of the subject product discloses to Divelbiss satisfaction that any defect has not been caused by misuse neglect improper installation improper operation improper maintenance repair or alteration accidents or unusual deterioration or degradation of the equipment or parts thereof due to physical environment or due to electrical or electromagnetic noise environment This warranty is in lieu of all other warranties expressed implied or statutory including warranties of merchantability or fitness for a specific purpose
4. section describes the SI APPMOD Tachometer Application Module including input output assignments and an oper ational description GETTING TO KNOW THE MODULE Status O 600 ti 12 13 14 Programming r Setpoint Variable Display g peppaquiz diy e uo 660 667 4 Waed NOILVYOdY09 mOFE YSN O1N0 umopouapasd WOD SSIQI Ap MMMy dYyY SSIQJ SAI hd 1 75 a 2375 The module is connected to external devices via its included mounting socket Connector Pin out Bottom View Solves lt Connector Pin 1 Setpoint 2 Output Pin 2 Setpoint 1 Output Pin 3 Tachometer Pulse Input Pin 4 Input 1 Not Used Pin 5 Input 2 Not Used Pin 6 Input 3 Not Used Pin 7 Earth Gnd Pin 8 Input Power Common Pin 9 10 24 5VDC_ Input Power Pin 10 Setpoint 4 Output Pin 11 Setpoint 3 Output Figure 2 1 Module Pin Out SI APPMOD Tachometer User Manual Document 2008012 0 pdf Page 3 of 8 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com I oY 0 f hy easy MODULE MOUNTING The Module mounts to an industry standard 11 pin Octal relay socket To mount the module align with the socket and firmly push into position MODULE INPUT POWER The module can be powered with 10 24 5VDC The input power must be of sufficient supply to drive the module and the outputs based on the load currents for each Maximum current for the module is
5. 150mADC and maximum load for each outputs is 300mADC For the pre programmed software 4 outputs are used and may be on ata time Exceeding a total output load of greater than 1ADC more than 3 outputs at full load simultaneously can damage the module 10 24 5VDC POWER IN DC POWER COMMON Status O 0000 I1 12 13 14 Programming Setpoint Variable Display APPLICATION MODULE Port INPUT POWER Shown installed in provided mounting socket B1 gt SI 2000 Figure 2 2 Module Input Power Diagram SI APPMOD Tachometer User Manual Document 2008012 0 pdf Page 4 of 8 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com I oye 0 2 E MODULE OPERATION The SI APPMOD Tachometer counts pulses on the Tachometer Pulse Input based on time and calculates RPM This calculation is based on a 60 tooth wheel or gear The update rate time over which pulses are counted is 1 second Four output channels are provided with programma ble setpoints When the RPM is equal to or greater than a channel s setpoint the output will energized USER INTERFACE The user interface consists of two push buttons labeled B1 and B2 the Setpoint Variable Display four LED indicators 11 14 and the Status LED indicator 1 Indicator 1 2 Indicator 2 On Steady indicates the Setpoint 1 value is displayed On Steady indicates the Setpoint 2 value is displayed on the
6. B1 button the indicator LED will stop flashing SI APPMOD Tachometer User Manual Document 2008012 0 pdf Page 7 of 8 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com I oY 0 2 E EXPANDABILITY CUSTOMIZATION As the module is based on the Solves It Model SI 200 the program can be customized and its functionality expanded Accessories are required The program that was factory installed can be downloaded from http www divelbiss com The program can be edited to add additional functionality and logic To gain functionality of some inputs and or outputs it may be necessary to re assign the I O that was factory configured For more information about changing the functionality download the Solves lt User Manual and the EZ LADDER User Manual The following accessories are required to re program the module and are included in the SIAPPMOD PGMKkIT 1 SI PGM 2 EZLDCD 02 Solves lt Programming Cable EZ LADDER Lite on CD PROGRAMMED FROM FACTORY SPECIFICATIONS Solves It Model 200 Based on PLC on a Chip Processor Memory 64K Flash Outputs 4 Sourcing SSR Outputs rated 10 24VDC 300mADC Max each Max total output load Power Requirements 1ADC 24VDC power input Output Voltage Input Power Functionality Setpoint Outputs 1 4 10 24 5VDC 150mADC Max Indicators 11 14 LED Indicator 1 Status LED Indicator Counter Inputs 1 Sourcing Input C
7. Setpoint Variable Display When flashing the on the Setpoint Variable Display When flashing the setpoint is being edited setpoint is being edited 3 Indicator 3 On Steady indicates the Setpoint 3 value is displayed on the Setpoint Variable Display When flashing the setpoint is being edited 4 Indicator 4 On Steady indicates the Setpoint 4 value is displayed on the Setpoint Variable Display When flashing the setpoint is being edited I2 13 5 Module Status Indicator Flashing slowly indicates module problem Programming r Setpoint Variable Display Flashing quickly indicated module is operating Port 6 B1 Push button Each press will cycle one step through the module setup menu The menu is displayed by the 11 14 indicators 1 Setpoint 1 2 Setpoint 2 3 Setpoint 3 4 Setpoint 4 7 B2 Push button For each Setpoint displayed pressing the B1 will increment the setpoint by one 1 Holding the B2 button will cause the setpoint to increase by tens hundreds and thousands the longer it is held pressed The setpoint wraps to zero after 9999 8 Setpoint Variable Display View and change the current setpoints Figure 2 3 User Interface PULSE INPUT CONNECTION The Tachometer Pulse Input is sourcing therefore requiring a sinking device be connected When the input is connected to common shorted to common the input is energized Figure 2 4 provides a sample connection SI APPMOD Tachome
8. n rail Socket 115 105328 In Box 4 Commutating Diodes 111 101012 In Box SI APPMOD Tachometer User Manual Document 2008012 0 pdf Page 1 of 8 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com GETTING STARTED This section explains how to read this manual and understand the symbols HOW TO USE THIS MANUAL In this manual the following conventions are used to distinguish elements of text BOLD Denotes labeling commands and literal portions of syntax that must appear exactly as shown italic Used for variables and placeholders that represent the type of text to be entered by the user SMALL CAPS Used to show key sequences or actual buttons such as Ok where the user clicks the OK button In addition the following symbols appear periodically in the left margin to call the readers attention to specific details in the text Warns the reader of a potential danger or hazard that is associated with certain actions Q Appears when the text contains a tip that is especially helpful Indicates that the text contains information to which the reader should pay particularly close attention All Information and Specifications Subject to Change without Notice SI APPMOD Tachometer User Manual Document 2008012 0 pdf Page 2 of 8 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com MODULE BASICS This
9. ount Up 25KHZ Maximum Display 4 Digit 7 Segment Programmable LED Display Push Buttons Operating Temp 2 Programmable Push Buttons 0 60 C Dimensions 3 62 Wide x 5 21 Length x 1 21 Tall Mounting Plugs into Industry standard 11 pin Octal Relay Socket Type Plastic Housing SI APPMOD Tachometer User Manual Page 8 of 8 Document 2008012 0 pdf Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com Limited Warranty Divelbiss Corporation warrants equipment will be free from defects in material and workmanship for a period of one 1 year from the date of the Divelbiss invoice that the equipment was furnished Divelbiss Corporation will not be liable for any design furnished by Buyer and incorporated into the equipment In no event shall Divelbiss Corporation be liable for anticipated profits consequential damages or loss of use of equipment or of any installation into which the equipment covered by this order may be put Divelbiss Corporation shall not be liable or responsible for any loss injury or damage resulting directly or indirectly from the use of software and or programming in any way associated with the equipment of this order Obligations are to be limited to the repair or replacement at the Divelbiss Corporation plant Fredericktown Ohio upon return of the part or component in question prepaid by Buyer The return freight charges to be paid by
10. ter User Manual Document 2008012 0 pdf Page 5 of 8 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com X 0 f hy ea DC POWER COMMON Status 600 ti 12 13 14 Programming Setpoint Variable Display Port r q SI 200 SINKING PULSE INPUT DEVICE TACHOMETER PULSE INPUT Figure 2 4 Pulse Input Connection OUTPUT CONNECTIONS When outputs are energized the output pin will be sourced with V equal to the module input power voltage Each output can drive a load up to 300mA maximum resistive Depending upon the device connected to an output a mini U mum load resistor may be required If the output is energized at all times connect a 4700 to 1KQ load from the output to common Figure 2 5 is a typical output wiring diagram The factory installed software for this module will only allow four outputs to be energized at a time Max total current for simultaneous outputs is 1ADC Simultaneous output loads greater than 1A may result in damage to the module Care must be taken to ensure the loads connected to the outputs if all channels are used does not exceed 1A SI APPMOD Tachometer User Manual Document 2008012 0 pdf Page 6 of 8 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com I oY 0 E CHANNEL 4 OUTPUT 1 ee LOAD DEVICE CHANNEL 3 OUTPUT LOAD