1. be on the same side as the screw heads 16 Slide a 8 aluminum spacer over each of the screws 17 Attach this assembly to the tab protector as shown in the photos 18 Loosely mount the tab protector to the underside of the digital readout bracket using the supplied 8 32 x 3 4 pan head screws Do not tighten completely at this time 19 Slide the readhead along the scale and up to the digital readout bracket assembly 20 Center the guide clip over the post on the readhead so that it applies light pressure Use the supplied washers and spacers to achieve the correct pressure the guide clip should flex approximately 1 16 Tighten all screws 21 Slide the fence left and right and check for binding Assure the readhead post remains centered in the guide clip with constant pressure over the full range of fence travel Digital Readout Installation 22 Remove the two screws on the front of the digital readout housing and set them aside Pull the cover off of the base Drill out the upper left and lower right hole locations they are partially drilled already Attach the digital readout base to the digital readout bracket using the supplied flathead screws Replace the digital readout cover and tighten screws 23 Connect the readhead cable to the digital readout 24 Verify the digital readout reads larger positive numbers when moved from left to right If it does not the readhead can be reversed on the scale or the digital rea
2. DigiFence Installation Instructions Please note this installation kit is designed solely for installation on the Commercial Powermatic Accufence and Commercial Jet XACTA Fence II Accurate Technology manufactures kits for other fences in which some or all of the components may be different For more information about ProKits please contact Accurate Technology SAFETY WARNING To avoid injury Before installing ProScale on a machine turn off the machine and disconnect it from its power source Warranty Accurate Technology Inc warrants DigiFence systems against defective parts and workmanship commencing from the date of original purchase Upon notification of a defect Accurate Technology Inc shall have the option to repair or replace any defective part Such services shall be the customer s sole and exclusive remedy Expenses incidental to repair maintenance or replacement under warranty including those for labor and material shall be borne by Accurate Technology Inc Except as expressly provided in this warranty Accurate Technology Inc does not make any warranties with respect to the product either expressed or implied including implied warranties of merchantability or fitness for a particular purpose except as expressly provided in this agreement Accurate Technology Inc shall not be liable for any special incidental or consequential damages for loss damage or expense directly or indirectly arising from t
3. below the surface of the scale 5 Slide the readhead back onto the scale if it was removed Be very careful to not damage the sensitive grounding fingers inside Mounting the Digital Readout Bracket 6 Remove the bolt that holds the cam lever to the fence 7 Replace it with the supplied 5 16 x 2 bolt 8 Slide the digital readout bracket onto this bolt lower hole of the digital readout bracket 9 Reinstall the 5 16 18 nut Hold the bracket level and tighten the nut 10 Mark the position of the digital readout bracket s upper hole onto the fence using a center punch 11 Temporarily loosen the 5 16 18 nut from step 9 and let the digital readout bracket swing clear of the marked hole 12 Drill the marked position with a 9 32 drill bit Be sure to drill through both sides of the fence Use the photos on the previous page as a guide 13 Slide the supplied 14 20 x 1 2 bolt through the right hole from the inside of the cam lock area and into the upper hole of the digital readout bracket Install the supplied 4 20 nut and tighten 14 Tighten the 5 16 18 nut Do not over tighten this nut it could make the fence lock hard to operate Accurate Technology Inc 800 233 0580 828 654 7920 Fax 828 654 8824 Instructions AccuFence AND Jet Retrofit Instructions Last updated 1 12 06 3 Guide Clip Installation and Setup 15 Place two 8 32 x 34 screws through the guide clip The slots of the guide clip should
4. dout s reading direction can be changed consult the included User Manual for details Accurate Technology Inc 800 233 0580 828 654 7920 Fax 828 654 8824 Instructions AccuFence AND Jet Retrofit Instructions Last updated 1 12 06 4 Calibration See User Manual for reference l 2 7 With the fence locked in position near the saw blade cut a small square board Measure this board with the most precise measuring tool available and write down the measurement Press ZERO on the digital readout Use the PLUS button to enter the measured value into the digital readout Press and hold the ON OFF button Quickly press and release the MODE button Release the ON OFF button The keyboard is now locked It can be unlocked by repeating this procedure The digital readout should be re calibrated when the saw blade is changed kerf allowance or when the batteries are changed Familiarize yourself and other operators with the product s functions by reading the User Manual Removing the Fence from the Saw If you should need to remove the fence follow these steps 1 2 Disconnect the readhead cable from the digital readout Disengage the guide clip from the readhead Slide the readhead to the left Slide the fence to the right and remove from the table Fasten the loose end of the readhead cable under the saw table to protect it from damage Be sure to recalibrate when the fence is re installed Accurate Techno
5. he customer s use of or inability to use the equipment either separately or in combination with other equipment Tools Required Q Set of small clamps Drill Motor Center punch 9 32 drill bit OR 5 16 drill bit Adjustable wrench Phillips screw driver Tap Handle Allen wrench set Ooooooveoo Some parts of this installation kit may have been pre assembled for your convenience by Accurate Technology Due to small differences in fence designs parts and installation may differ slightly from those shown Installation Photos Digital Readout Bracket Tab Protector Readhead Scale Display Display Bracket Scale Readhead Guide Clip Tab Protector 5 16 18 nut 14 20 x 2 Bolt Accurate Technology Inc 800 233 0580 828 654 7920 Fax 828 654 8824 Instructions AccuFence AND Jet Retrofit Instructions Last updated 1 12 06 2 Mounting the Scale 1 Place the scale on the underside of the fence tube so the right end of the scale is flush with the right end of the fence tube and the inside edge of the scale rests against the edge of the angle iron 2 Use a center punch to mark the hole locations on the underside of the fence 3 Drill and tap holes into the fence tube using the supplied drill and tap at the marked locations Be sure the holes go completely through the metal Remove any burrs 4 Attach the scale using the supplied flathead screws Be sure the screw heads are flush or
6. logy Inc 800 233 0580 828 654 7920 Fax 828 654 8824 Instructions AccuFence AND Jet Retrofit Instructions Last updated 1 12 06 5 Troubleshooting The reading is accurate close to the saw blade but not accurate at larger distances Q Check the alignment of the saw fence The alignment will affect the measurements at larger distances a Also be sure to check the mounting of all components Any loose bolts can allow for slop measurements The digital readout resets itself while saw is running and the fence is locked a The digital readout has been accidentally reset Large voltage spikes from nearby motors inverter and dust collection systems can cause this Be sure that all devices are properly grounded Q Also extreme vibration can cause this Mount the digital readout in a different location Q Be sure the ABS INC key if equipped has not been accidentally pressed If so press and hold for 3 seconds to return to ABS reading The digital readout resets itself while the saw is not running and the fence is locked Q Be sure the ABS INC key if equipped has not been accidentally pushed If so press and hold for 3 seconds to return to ABS reading a Be sure the ZERO button has not been accidentally pushed If so you will need to recalibrate the saw fence Be sure to lock the value into the digital readout The digital readout reads ERR 2 or No Enc Q Make sure the connector is fully inserted into the digital read
7. out Also be sure the readhead is on the scale To clear the error simply unplug the readhead for one second and re insert the connector to the digital readout You will need to recalibrate a The fence has been moved too quickly To clear the error simply unplug the readhead for one second and re insert the connector to the digital readout You will need to recalibrate The digital readout reads shows a battery symbol Q Your batteries need to be changed The digital readout uses two standard AA alkaline cells To change the batteries unscrew the top cover two screws and remove old batteries Be sure to avoid touching the brass battery contacts as much as possible These are specially designed to be loose while you are changing batteries do not attempt to bend them My problem is not listed where do I get help Q Read through all the manuals for answers to other commonly asked questions Q Check Accurate Technology s web site for more information Q Contact Accurate Technology at 828 654 7920 Have the following information ready when calling machine model part number date of purchase and point of purchase a E mail our service department at customerservice accurate technology com Accurate Technology Inc 800 233 0580 828 654 7920 Fax 828 654 8824 Instructions AccuFence AND Jet Retrofit Instructions Last updated 1 12 06 6

Download Pdf Manuals

image

Related Search

Related Contents

PortableTesters Catalog 2014  DENSITÉ series SPG-1801 Sync Pulse Generator Module  Avaya T7406 Installation Guide  Mode d`emploi VOCAFLEX - skil  取扱説明書 - yodobashi.com  Fiche produit Deb® Pure RESTORE    44-758型 取扱説明書 ガス温水暖房システム 暖ライフ  Electro Splash User Manual  User Manual-SDE-5001-GERMAN_Web-.indb - hv  