moisture analyzer white paper

image

Contents

1. Harrison Court South Orange NJ 07079
2. with the halogen lamp it is located in the lid Cleaning is done in the same fashion as for the base of the unit Avoid touching the halogen lamp If you must touch the lamp use lint free gloves to avoid transferring oil from your skin to the lamp surface Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH Do you have a Short List of Specifications to Check Out Maybe not so short but here is a quick summary of things to look for when comparing moisture analyzers 1 Readout also called resolution or readability This is the smallest unit that can be displayed on the panel and is presented in grams and percent moisture Many moisture analyzers display to 0 001g or 0 01 moisture When specifications call for very low moisture content such as for certain plastic resins select a balance with a resolution of 0 0001g or 0 001 moisture 2 Repeatability the ability of a moisture balance to display the same result when the same sample is tested repeatedly It is expressed as a standard deviation 3 Specialized capabilities such as providing graphic displays of the drying profile and building libraries of frequently performed test parameters 4 Temperature range range from 50 to 160 C to broader ranges such as 30 to 200 C The temperature can usually be set in increments of 1 C 5 Some models have only one drying mode and others have several such as standard soft fa
3. TOVATECH 13 THINGS TO KNOW ABOUT MOISTURE ANALYZERS by Rachel Kohn Ph D Tovatech LLC TOVATECH Moisture content is a quality control criterion signifying the amount of moisture in a product Laws as well as industry trade associations define the correct moisture content for a broad range of products including pharmaceuticals plastics wood chips fabrics paint body lotion seeds tobacco potting soil dried fruits and vegetables catsup grains etc More than quality is involved For products sold by weight too much moisture means the customer is paying for water instead of product If moisture content is below spec more is required to fill the package and the vendor takes the hit Ascertaining the amount of moisture in a sample is accomplished with a moisture analyzer These devices calculate moisture content in several ways one of the most common being the thermogravimetric method or loss of weight on drying LOD The LOD process equates to the amount of moisture removed by evaporation when the sample is heated Simply stated a thermogravimetric moisture analyzer pairs a scale with a heater This white paper will help you understand moisture analyzers a k a moisture balances by explaining their components how they work and specification criteria But if you have any questions our scientists are ready with the answers Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Ora
4. Temperature tests are conducted at two points and take longer than the weight calibrationexercise Instructions are provided to perform the correcting adjustment s if there is a discrepancy between the temperature displayed on the probe and the analyzer Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH How are Moisture Balances Maintained Maintenance instructions are provided in the user manual Here is a general summary First of all position your moisture analyzer in a protected area away from drafts dust temperature extremes and vibration Remember that every time you move it you must recalibrate it Use a soft brush or gentle vacuum to immediately remove samples that fall off the sample plate Use extreme caution to ensure no liquid penetrates the device For general maintenance unplug the unit and remove accessory parts such as the sample dish the dish retainer the sample dish holder the draft shield and its associated base plate These can be individually washed using soft cloth dipped into water containing a mild liquid dishwashing soap and wrung out Do not use solvents or other aggressive cleaning agents After cleaning wipe the components with a cloth dampened with fresh water then dry them with another soft cloth The same cautions apply to the body of the moisture balance The moisture balance temperature sensor is an extremely delicate component Along
5. eans for example should be crushed before testing Samples should be spread thinly and evenly on the sample pan Samples with high moisture or oily content such as honey milk and body lotion should be placed between fiberglass filters so they spread evenly across the Sample pan This not only increases surface area to speed the analysis but also prevents spattering inside the unit Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH What is the Correct Sample Size The optimum sample weight is usually established after several trials Moisture analyzer operating manuals may suggest weights for specific products but these are only suggestions In general the sample should be sufficient to thinly cover the surface of the sample tray and evenly distributed to avoid lumps or peaks Large sample sizes do not equate to more accurate readings except as noted below The moisture balance operating manual will specify its maximum capacity Tip Low moisture values such as below 1 are difficult to gauge and require larger samples As an example for a 1 moisture content you may need a 2 gram or more sample but for a sample with a 0 1 estimated moisture content you may need a 20 gram or more sample Lower moisture samples require a more sensitive moisture analyzer This is determined by its readout Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court Sout
6. ect sensitive samples from decomposing or forming a protective skin In the soft drying cycle samples are heated evenly from the outside to the inside by heat convection For samples with moisture content between 5 and 15 a fast drying cycle can be programmed into the unit With this setting the halogen heater quickly raises the temperature to approximately 40 above the set temperature called preheat to rapidly drive off the bulk of the moisture and then returns it to the set temperature to approach the end point slowly Step drying can be used in the same way as fast drying primarily for samples with more than 15 moisture It can also be used for measuring two different types of moisture in the same sample such as surface moisture and bound moisture Individual increments of time and temperature are programmed into the moisture analyzer Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH How Important is Sample Preparation Very important in terms of sample surface area size weight and placement on the moisture analyzer sample pan Here are some suggestions Samples should be representative of the bulk material being tested Samples should be tested immediately after being taken from the bulk material Otherwise they could give up to or absorb moisture from the local environment Small particles will analyze quicker because of increased surface area Grains and b
7. h Orange NJ 07079 TOVATECH What are Switch Off Criteria Switch off criteria are selected by the operator depending on the samples under analysis and the required accuracy Three methods of shutoff are common to most moisture analyzers 1 automatically when drying is complete and the dry weight is stable 2 after a specified time or 3 manually A stable dry weight is established when the weight loss per unit of time falls below a specified value Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH What is Calibration and Why is it Important As with all precision balances accuracy is a paramount requirement for a moisture analyzer Accuracy is set and maintained by initial calibration and periodic recalibration the latter of which is performed based on schedules contained in a company s operations manual In the case of moisture analyzers two calibration processes should be performed one for weighing accuracy and one for temperature accuracy External calibration is the process used to check the weighing accuracy of most moisture analyzers This is performed by using the recommended adjustment weight such as 50 g for the particular moisture balance being tested Calibration procedures are outlined in the operating instructions accompanying various models of moisture analyzers Temperature calibration kits are available to check the accuracy of the heaters
8. nge NJ 07079 TOVATECH So What is Moisture This is an excellent question A moisture balance measures anything that evaporates on heating In addition to water this may include fats oils alcohol and solvents If it adheres to the sample surface it can be termed adhesive free water or hygroscopic moisture Moisture absorbed by a material is called absorbed or equilibrium moisture Water can also be chemically bonded at the molecular level in which case it is called water of crystallization or hydrated water In this case the moisture is called bonding moisture or combined water Tip Certain volatile substances may be given off during a moisture analysis Procedures should be in place to take these into account Do not perform analyses on explosive or flammable materials or those that become hazardous on heating Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 ES TOVATECH How do Moisture Analyzers Work It is a 3 step procedure Parameters of the drying process are entered ona keypad The sample is placed in a drying chamber and the analysis begins The instrument calculates the moisture content by comparing the initial weight of the sample to the weight after drying is complete Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH What are the Components of a Moisture Balance As noted above the unit is compri
9. sed of a heater mounted on anprecision balance equipped with a control panel and display Other components include a sample pan holder and sample pans Fiberglass filters are available to either cover or Sandwich samples to improve heat absorption avoid splashing or protect them from developing a film or crust during the heating process Moisture balances with a memory function allow researchers to build a library of frequently used analysis programs An RS 232 interface connects to computers or printers for record keeping Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH You Mentioned Display What is Displayed Backlit LCDs provide a wealth of information the extent of which depends on the particular model Examples include current weight current moisture content in the drying mode see below the switch off mode see below the previous drying time the current temperature and an indicator that the drying process is active As suggested above data can be transferred via an RS232 interface to a printer or computer for record keeping Units are available with software delivering a real time graphic display of the moisture loss profile to your computer Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH How is Heat Applied to Samples Halogen or infrared heaters are commonly used These are mounted on preci
10. sion balances The instrument can be programmed to conduct the analysis in accordance with procedures recommended by industry trade associations and government agencies As to the difference halogen is much faster Temperature is generally maintained within 1 C of the selected setting While most analyses involve increasing the temperature to a maximum of 160 C or less in special cases higher temperatures may be necessary to achieve complete drying Note that there are other methods including microwave and the Karl Fischer method Microwave drying instruments are somewhat larger and significantly more expensive than halogen heated moisture analyzers The Karl Fischer titration method while accurate uses hazardous solvents requires skilled technicians and that the water in the sample be accessible to the reagent in order for the method to work The method detects only water whereas thermogravimetric analyzers detect any volatile substance in the sample Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH What are Drying Modes or Profiles Not all substances react equally to a moisture analyzer Because of this some models offer a programmable heating profile The most commonly used mode is standard drying which is suitable for most substances The soft or gentle drying mode is recommended for samples that do not tolerate the full power of the halogen heater This helps prot
11. st and step 6 Switch off criteria by time weight loss per unit of time or manual 7 Maximum sample weight with 50 to 70g typical but some units have higher Capacities 8 Some models come with a calibration weight and for others the weight must be purchased separately 9 Warranties vary Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 TOVATECH How do I Decide on Optional Equipment i Standard and optional equipment are defined by the moisture analyzer manufacturer Certain items described above such as temperature calibration sets are usually optional The same applies to this list of accessories or options that will prove useful immediately or down the line e Aluminum sample plates e Fiberglass filters e Printers matrix or thermal e Calibration weights if not included e RS 232 Interface if not included We hope the information here is useful when selecting a moisture analyzer For additional information and recommendations on selecting equipment please contact the scientists at Tovatech for expert advice on the right unit for your applications Tovatech LLC Phone 973 913 9734 contact tovatech com 11 Harrison Court South Orange NJ 07079 ES TOVATECH Need to talk to someone about moisture analysis aS 973 913 9734 Ba CHAT WITH US NOW MAZ RITE TO US NOW Tovatech LLC Phone 973 913 9734 contact Atovatech com 11