UK/0126/0008 Revision 1
Contents
1. 6 2 Access to the configuration and calibration facility for the 1310 weighing module s is via a push button located on the power supply PCB and is accessed through a hole in the rear of the indicators enclosure The plastic screw which prevents access to the push button can be secured to the back of the enclosure by a wire and seal Components that may not be dismantled or adjusted by the user including the load cell junction box if applicable must be secured by either a wire and seal or a tamper evident label and securing mark 6 9 The securing mark may be either a mark of the manufacturer and or manufacturer s representative or an official mark of a verification officer 7 ALTERNATIVES There are no alternatives 8 ILLUSTRATIONS Figure 1 Photograph of the instrument Figure 2 1310 indicator Figure 3 Data plate 9 CERTIFICATE HISTORY ISSUE NO DATE DESCRIPTION UK 0126 0008 25 June 2007 Type examination certificate first issued UK 0126 0008 Revision 1 25 July 2008 Modification to section 3 3 2 7 9 3 pin ow ta Figure 1 Photograph of the instrument Figure 2 1310 indicator 8 9 Avery Weigh Tronix LL Max 30kg 2206 2407 SOG6O0HZ Min 400 g 16A MAX a209 10 C 40 C Class Y a Cert No UK 0126 0008 emon Figure 3 Data plate Crown Copyright 2008 NATIONAL WEIGHTS AND MEASURES LABORATORY Department for Innovation Universities amp Skills 9 9
2. UK 0126 0008 NWML MI 006 NATIONAL WEIGHTS AND MEASURES LABORATORY United Kingdom of Great Britain and Northern Ireland Certificate of EC type examination of a measuring instrument Number UK 0126 0008 Revision 1 issued by the Secretary of State for Innovation Universities amp Skills Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments Automatic Catchweighers Regulations 2006 SI 2006 1257 and the Measuring Instruments Non Prescribed Instruments Regulations 2006 SI 2006 1270 which implement in the United Kingdom Council Directive 2004 22 EC this certificate of EC type examination has been issued to Avery Weigh Tronix Ltd Foundry Lane Smethwick West Midlands B66 2LP United Kingdom in respect of an automatic catchweighing instrument as described in the descriptive annex and having the following characteristics 6000 e 20e Maximum capacity Max Minimum capacity Min Accuracy class Y a IV IA The necessary data principal characteristics alterations securing functioning etc for identification purposes and conditions when applicable are set out in the descriptive annex to this certificate This revision replaces previous versions of the certificate Signatory PR Dixon for Chief Executive National Weights amp Measures Laboratory Department for Innovation Universities amp Skills Stanton Avenue Issue Date 25 July 2008 Teddington Valid Until 24 June
3. 10 controller module which receives product information from the management system and creates the start of shift program and sets the parameters for the weighing modules and label printers applicators It includes the same set of electronics as utilised in the weight indicators including the power supplies 2 2 3 The 1310 weight indicator s contain all of the electronics associated with the weighing processes including regulated power supplies all as described in EC Test certificate GB 1153 2 3 Load cell Any compatible load cell s may be used providing the following conditions are met There is a respective OIML Certificate of Conformity R60 or a Test Certificate EN45501 issued for the load cell by a Notified Body responsible for type examination under Directive 90 384 EEC The certificate contains the load cell types and the necessary load cell data required for the manufacturer s declaration of compatibility of modules WELMEC 2 Issue 4 2004 section 11 and any particular installation requirements A load cell marked NH is allowed only if humidity testing to EN45501 has been conducted on this load cell The compatibility of load cells and indicator is established by the manufacturer by means of the compatibility of modules form contained in the above WELMEC 2 document The load transmission conforms to one of the examples detailed in WELMEC 2 4 Guide for Load Cells 2 4 Devices 2 4 1 The instrument is provid
4. 2017 Middlesex TW11 0JZ Reference No T1110 0010 United Kingdom Descriptive Annex 1 INTRODUCTION This pattern of an automatic catchweighing instrument operates as an automatic weight labeller Category Y It comprises two weighing devices with associated thermal label printers and mechanical handling facilities and is designed to weigh packs statically Pack and labelling information is stored in data files selectable for the commodity and or labels being processed Labels are printed with the required transaction data and are applied to packs automatically 2 FUNCTIONAL DESCRIPTION 2 1 Mechanical 2 1 1 The instrument Figure 1 is constructed in stainless steel The supporting framework is a fabricated floor standing stainless steel frame on adjustable feet on which are mounted four modular motorised conveyors weighing module scanner module 2 weighing module and 2 scanner module driven by de motors A level indicator is provided on each weighing module 2 1 2 Each weighing module is connected to an AWTX model 1310 weight indicator Figure 2 which is mounted below the conveyors with both indicators connected to an AWTX model 1310 controller module which controls the complete system Label printers applicators are mounted above each weighing conveyor and fixed barcode scanners are mounted above each scanner conveyor Four photocells one per module are used for pack detection 2 1 3 The control cabinet is fixed to the front of
5. arked VERS Sequence through the screens to view the details of the software embedded in the 1310 indicator 5 The identity and checksum of the Weighing Application are given on the fifth screen titled SIMPOSER CONFIGURATION FILE On this screen five comma separated fields are given The fields in order are Indicator Model The tool version used to download the file The file name used as the checksum of the programmed software The time the software was downloaded The date the software was downloaded 3 3 3 The 1310 controller module transmits the tare weight to each 1310 weighing module The tare value is stored in the PLU selected on the 1310 controller module 3 3 4 Each label printed and applied to the packs is provided with a sequential number The sequential number is unique to each 1310 weighing module and identifies the stored data string for each pack 4 PERIPHERAL DEVICES AND INTERFACES 4 1 Interfaces Load cell connection hardwired 3 x RS232 RS422 e 1 x powered RS422 20 mA 4 2 Peripheral devices The instrument may be connected to any peripheral device that has been issued with a test certificate by a Notified Body responsible for Annex B MI 006 under Directive 2004 22 EC in any Member State and bears the CE marking of conformity to the relevant directives or 5 9 A peripheral device without a test certificate may be connected under the following conditions it bears
6. ed with the following devices Semi automatic zero setting device not operable during automatic operation Automatic zero setting device maximum period between zero setting of 1 hour Zero tracking device Zero indicator Tare weighing or balancing device Preset tare device Net indicator Gross B G indicator Real time clock Device to determine when stability criteria are fulfilled 3 9 3 TECHNICAL DATA 3 1 The instrument has the following technical characteristics Power supply 220 240 Vac 50 60 Hz Maximum number of scale intervals 6000 Load cell excitation voltage 10 Vdc Minimum load cell impedance 28 Q Maximum load cell impedance 1100 Q Minimum input voltage per verification scale interval 2 nV Measuring range minimum voltage 12 mV Measuring range maximum voltage 50 mV Fraction of maximum permissible error Ping 0 5 Climatic environment naan Non condensing closed Electromagnetic environment El and E2 Accuracy class Y a 6 core with braided outer screen 0 5 mm per core flexible PVC Load cell cable overall jacket Maximum length 5 m 10 m mm 3 2 Documentation and drawings Document Drawing No Description EAWI 10001 Functional design specification EAWI 10001 Software design specification 103494 UM V1 1 User manual 50692 Main PCB assembly 50693 Main PCB circuit diagram 51571 Multi channel analogue outp
7. the CE marking for conformity to the EMC Directive 89 336 EEC it is not capable of transmitting any data or instruction into the weighing instrument other than to release a printout checking for correct data transmission or validation it prints weighing results and other data as received from the weighing instrument without any modification or further processing and it complies with the applicable requirements of Directive 2004 22 EC Paragraph 8 1 of Annex I 5 APPROVAL CONDITIONS The certificate is issued subject to the following conditions 5 1 Legends and inscriptions 5 1 1 The following legends are durably and legibly marked on the instrument CE marking Supplementary metrology marking Notified body identification number Accuracy class Serial number Manufacturers mark or name Certificate number Operating temperature range 5 2 If the instrument is not permanently installed it shall be provided with a level indicator 6 LOCATION OF SEALS AND VERIFICATION MARKS 6 1 The CE marking supplementary metrology marking and certificate number are located on the mounting plate bracket which is fixed to the main structure of the conveyor stand The CE mark shall be impossible to remove without damaging it The data plate Figure 3 shall be impossible to remove without it being destroyed The markings and inscriptions shall fulfil the requirements of Paragraph 9 of Annex I of the Directive 2004 22 EC
8. the stainless steel frame and houses the conveyor based electrical hardware relay box operator controls and pneumatics for the label applicators 2 1 4 Packs are delivered to the first weighing conveyor by the customer supplied in feed conveyor and once detected by the associated photocell the conveyor is stopped by the 1310 controller module for the weighment to take place and the label to be applied The pack is then transported to the first scanner conveyor where the barcode is read by the scanner If the data from the scanner is read correctly and agrees with the data stored then the pack continues across the third and fourth conveyor modules without further processing by the system and is transported onto the customer supplied out feed conveyor If an error is detected by the scanner the weighing operation is then automatically assigned to the second weighing module and an error signal generated to indicate a fault on the primary weighing module Once weighed and labelled the pack is then transported to the second scanner module for data integrity checking 2 2 Electrical 2 2 1 The electrical hardware is located within the 1310 indicator modules the 1310 control module thermal label printers and a control panel The control panel is mounted on the front of the instrument and contains the motor controls with associated power supplies AWTX SSCU8 relay box and operator controls 2 9 2 2 2 The control of the instrument is provided by the 13
9. ut PCB assembly 51572 Multi channel analogue output board circuit diagram 53021 Network interface PCB assembly 50799 Serial I O and PSU PCB assembly 50800 Serial I O and PSU circuit diagram 51631 Display and keyboard interface PCB assembly 51632 Display and keyboard interface PCB circuit diagram 3 3 Software 3 3 1 The weighing software is contained within the 1310 indicator modules and the version number is 52957 0137 The software version number is accessed by Hold in the escape key until the indicator beeps For the User Menu enter the password 111 and press the enter key 4 9 From the User menu press the soft key marked VIEW From the View menu press the soft key marked VERS 3 3 2 The main process control software is contained within the 1310 controller module and its version number is V1 2 x x where x x denotes a sequential number starting with 0 1 detailing the exact release level Any changes denoted by the release level x x will be non metrologically significant The indicator modules also include a limited version of the controller module software and the version number is V1 3 The version numbers for both units are displayed at power up and the checksum value is accessed by Hold in the escape key until the indicator beeps For the User Menu enter the password 111 and press the enter key From the User menu press the soft key marked VIEW From the View menu press the soft key m