Home
AlcoScan AL3500SC
Contents
1. ALCOSCAN AL3500 AL3500SC Coin Op Bill Op Breath Alcohol Tester OPERATING MANUAL CONTENTS 1 Introduction 2 Parts and Functions Display Panel 3 Device Operation 4 Warnings Precautions 5 Maintenance 6 Troubleshooting 01 Page 02 Page 03 Page 05 Page 08 Page 09 Page 14 INTRODUCTION The AlcoScan AL3500 is a coin or bill operated breathalyzer breath alcohol tester suitable for use in bars restaurants and other commercial locations Interactive voice prompts integrated ARS automatic voice response system and bright LED indicators on the front of the device provide a quick and easy way for users to check their alcohol levels in BAC The AL3500 features advanced oxide semiconductor sensing technology as well as patent pending Pre Calibrated Replaceable Sensor Modules that can be used in place of calibration IMPORTANT The only legally valid measure of BAC percent Blood Alcohol Concentration is obtained by blood testing This device is for screening purposes only and should be used as a guide for self monitoring 02 PARTS AND FUNCTIONS 01 Mouthpiece Slot Bullseye 05 Fan 02 Coin Slot or Bill Validator 06 Speaker 03 Display Panel 07 Power Socket 04 Straw Tray 03 DISPLAY PANEL ALCOHOL ANALYZER 01 Ready Indicator 02 Wait Indicator 03 Blow Indicator 04 Finish Indicator 05 LED Alcohol L
2. Make sure you are using the proper type and number of coins or bills Also check your money acceptor setting as described on Page 10 in this manual 3 When you blow into the machine during a test there is no response from the machine See if the LED display shows error code SEn If so check the error codes on Page 14 in this manual Another common problem is that the sensor module is not seated correctly Open the rear door of the AL3500 and make sure that the sensor module is securely attached near the top of the main circuit board 4 There are no interactive voice prompts and or audio The voice prompt and audio options can be adjusted in Advanced Configuration Mode See Page 11 in this manual 5 After a breath test the AL3500 does not return to normal operating mode After each test the AL3500 displays the results for approximately ten seconds In order to return to normal operating mode for a new test the alcohol residue from the current test must be removed completely This is an automatic process but may take longer if there is a high alcohol reading up to one minute If this takes much longer than one minute there may be a problem with the sensor assembly Contact technical support using the information below to resolve your issue 6 I have a problem that is not covered in this Troubleshooting section Please contact technical support 800 943 1016 Toll Free 201 943 9411 New Jersey 201 943 8828 F
3. done by simultaneously pressing and holding both SET1 and SET2 for two seconds While you are in Advanced Configuration Mode tapping SET1 will cycle through the options of Buzzer Sound Lo and Hi SET2 will change the setting for each option Buzzer Tap SET1 until you see buz in the LED display Tap SET2 to turn the buzzer audio beeps on or off Sound Tap SET1 until you see Snd in the LED display Tap SET2 to turn the interactive voice prompts on or off Alcohol Level Low Limit This setting adjusts the detected alcohol level below which the AL3500 will light the Good Indicator after a test is performed The default setting is 0 02 We do not recommend changing this setting Tap SET1 until you see Lo in the LED display Tap SET2 to adjust the limit from 0 00 to 0 04 Alcohol Level High Limit This setting adjusts the detected alcohol level above which the AL3500 will light the Danger Indicator after a test is performed The default setting is 0 05 We do not recommend changing this setting Tap SET1 until you see Hi in the LED display Tap SET2 to adjust the limit from 0 05 to 0 10 REPLACING SENSORS The AL3500 is equipped with Pre Calibrated Replaceable Sensor Modules Although every consumer breathalyzer requires periodic re calibration the AL3500 allows you to simply discard an old or worn sensor and replace it with a brand new sensor module Sensor Replacement
4. is recommended approx every 300 tests or at least once a year whichever is sooner Sensor modules can also be replaced if there is defect or malfunction in the sensor Sensor Module Replacement Instructions Step 1 Power off the AL3500 VERY IMPORTANT The new sensor may be severely damaged if power is on Step 2 Remove the old sensor module from the AL3500 circuit board and replace it with a new sensor module Step 3 Make sure the sensor module is seated securely and power on the AL3500 13 TROUBLESHOOTING ERROR CODES There are two error codes that may be shown in the LED display in cases of malfunction or other problems Er3 This code may appear if an improper coin is inserted into the coin slot causing it to get stuck inside the coin acceptor Try turning the coin release lever or examining the coin acceptor by opening the rear door of the device SEn This code may appear if the sensor module is not installed properly or ifthere is a problem or malfunction in the sensor You will most likely need to replace the sensor module COMMON PROBLEMS 1 The AL3500 does not power on Make sure that the power cable is securely attached to both the wall socket as well as the power socket at the bottom of the AL3500 Also check inside the AL3500 te make sure that the wiring from the power socket is properly connected red black wires at the bottom 2 Money is inserted but the test doesn t activate
5. of alcohol it may not be safe to drive LED Indicator WARNING BAC between 0 02 and 0 05 Voice prompt The device detects a moderate level of alcohol Please wait at least an hour or more and try another test It may not be safe to drive LED Indicator DANGER BAC greater than 0 05 Voice prompt The device detects a high level of alcohol It is NOT safe to drive 06 IMPORTANT NOTE Ifthe user does not blow into the straw after money is inserted and the countdown runs to 0 a ten second timer will appear in the display If a breath sample is not given and the timer runs out the test can no longer be taken Money will not be refunded 07 WARNINGS PRECAUTIONS Make sure you carefully read this section before using the AL3500 Please wait at least 20 to 30 minutes after drinking eating or smoking before performing a breath test with the AL3500 Liquid alcohol cigarette smoke excess saliva and other contaminants in the mouth can greatly affect the test results Do NOT use the AL3500 as a tool to drink and drive The only legally valid measure of BAC percent Blood Alcohol Concentration is obtained by blood testing or other evidential procedure The AL3500 is for screening purposes only and should be used as a guide for self monitoring 08 MAINTENANCE The AL3500 offers powerful features and performance as well as convenient user friendly configuration There a
6. AX Imported amp Distributed By AK Solutions USA LLC 21 Grand Ave Suite 102 Palisades Park NJ 07650 Toll Free 800 943 1016 New Jersey 201 943 9411 FA X 201 943 8828 support AlcoMate net www AlcoMate net
7. evel Display BAC 06 Good Indicator BAC lt 0 02 07 Warning Indicator BAC from 0 02 0 05 08 Danger Indicator BAC gt 0 05 04 DEVICE OPERATION Step 1 Insert the appropriate number of coins or bills into the coin slot Voice prompt Thank you Please take a straw from the tray and wait until the machine counts down to 0 in the display Step 2 Take a straw from the tray and insert it into the mouthpiece slot bullseye When the device indicates Blow blow into the mouthpiece steadily until the device indicates that sampling is completed If a successful sample is not taken the device will prompt you to wait then blow another breath sample until sampling is successful Voice prompt Insert the straw securely into the bullseye until the tone ends Three two one lt CHIME SOUND gt Sampling is completed Voice prompt if successful sample is not taken usually due to weak breath The device does not sense a proper breath sample Please wait and try again 05 Step 3 After a successful sample is taken the device will analyze the sample and display the alcohol level as BAC Blood Alcohol Concentration In addition to displaying the BAC an LED indicator will also light up as described below LED Indicator GOOD BAC less than 0 02 Voice prompt The device detects very little or no alcohol However if you have had ANY amount
8. re many customizable functions available In order to configure the AL3500 open the rear door of the device and locate the three buttons along the left side of the circuit board The buttons are labeled SET1 SET2 and TEST from top to bottom NOTE The TEST button automatically starts a breath test on the AL3500 equivalent to inserting coins o SET1 SW1 oe SET2 SW2 oe TEST SW3 09 CUMULATIVE TEST COUNTER In order to check the total cumulative number of tests performed on the AL3500 press SET1 for one second The LED display on the front of the device will show the number of tests Press and hold SET1 for two seconds to reset this test counter to zero If no commands are entered for several seconds the device and display will return to normal operating mode MONEY ACCEPTOR CONFIGURATION In order to adjust the number of coins or bills required to take a breath test on the AL3500 press SET2 for one second The LED display on the front of the device will show a number from C01 to C10 depending on the current setting for the number of coins or bills Tap the SET2 button to change the number of coins bills If no commands are entered for several seconds the device and display will return to normal operating mode ADVANCED CONFIGURATION MODE Buzzer Sound Lo Hi Levels If you want to adjust the buzzer sound and Lo Hi Levels you must access the Advanced Configuration Mode This is
Download Pdf Manuals
Related Search
Related Contents
Vaccins à jour - Société valaisanne de pharmacie EXS770 - Support MVW01 Convertidor de Frecuencia de Media Tensión ZS-M50 Dirt Devil SD20000RED Use and Care Manual Oster FPSTCF7500-022 Instruction Manual Bluetooth&#174 class 1 evaluation boards using Elevação - Mitsubishi Electric Copyright © All rights reserved.