Home
User manual - Wassermann Dental
Contents
1. 50 Hz 0 5 A Si 2 A 95 W 380 min up to 240 seconds adjustable approx 950 mbar min 5 bar IP 22 Width 205 mm Height 365 mm Depth 295mm 11 5 kg without wall mount 12 7 kg with wall mount Noise emission lt 70 dB A D We reserve the right to make technical changes WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor 10 EC COMPLIANCE CERTIFICATE In accordance with 73 23 EWG low voltage guidelines modified by 93 68 EWG and 89 33 VEWG EMV guidelines and 89 392 EWG Machinery guidelines with modifications Manufacture WASSERMANN Product description Vacuum mixer for Dental Maschinen GmbH dental applications Rudorffweg 15 17 D 21031 Hamburg Model Wamix Classic 171987 Wamix Injector 171986 Wamix Class c 115V 171981 Wamix Injector 115V 171980 Applicable standards EN 61010 1 1993 A2 1995 EN 50081 1 EN 50082 1 DIN 45635 1 Hiermit wird best tigt dab die oben bezeichnete Maschine den genannten EG Richtlinien entspricht Diese Erkl rung wird ung ltig falls die Maschine ohne unsere Zustimmung ver ndert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur de la Communit Europ ene Cet avis est nul et non avenant si cette machine est modifi e sans notre accord Esta m qui
2. Only for WAMIX Injector Turn the rotary knob to set the vacuum the first time the unit is used The recommended input pressure is a minimum 5 bar The regulator knob 2 Fig 1 is located on the right of the front panel Open the valve slowly from zero until the needle is in the green zone The best vacuum will not be obtained if the valve is fully open a middle setting is best This should be adjusted later if the pressure changes il WAMIX Injector If the needle does not reach the green zone on the pressure gauge there is too little flow to the unit Check the compressed air supply see also 4 2 il If the equipment will not be used for an extended period switch off the compressed air supply and the vacuum mixer 6 Operating the mixer All instructions for using the unit whether verbal written or in the form of practical guidance are based on individual experience and experimentation and can only be regarded as guidelines Fill the beaker to the Max marking The vacuum will draw any excess material into the system The beaker will come away automatically once the vacuum is removed To avoid damaging the seal never remove the beaker by force The sealing surfaces between the beaker and the plate must be E clean likewise rotor fastenings and beaker lid to ensure trouble free operation a WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 6 1 VACUUM MIXING with the
3. he mixer switches on automatically for the set time When the time has expired an acoustic signal sounds 6 Take hold of the beaker before you switch off the master switch 1 vacuum After the vacuum in the beaker drops the beaker will no longer be clamped to the unit 10 a WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor 7 Troubleshooting Likely cause Likely solution Mixer does not start Blown fuse Replace fuse and determine cause otherwise call Service Center WAMIX Injector Set timer to 0 Set mixing time Classic Vacuum too low Filter vacuum blocked Check filter clean and or change see 8 2 Leaking seal on vacuum Replace seal flange for mixing beaker No vacuum Beaker filled above Max Clean system i e mark i e mixing maintenance by Service ingredients in system Center Wamix Classic Faulty vacuum pump Maintenance by Service Center WAMIX Injector Set pressure regulator to Check and set pressure if 0 pressure gauge necessary Beaker falls out Faulty seal Replace seal 171708 il If the above suggestions do not solve the problem get in touch with your dental depot or our Service staff Service number Wassermann Dental Maschinen 49 0 40 730 926 0 11 ap WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 Care and maintenance 8 1 Cleaning The unit should be cleaned at regular intervals to ensure problem free operation It requires onl
4. WAMIX Injector 1 Set the mixing time with the timer 3 up to 240 sec automatic mixing this remains the default until a new time is set For manual mixing turn the timer to 0 and set the desired mixing time after a vacuum is present 2 Place the mixing materials in the beaker and mix by hand until the powder is well mixed with the liquid 3 Seal the beaker with a lid 4 Insert the beaker in the unit from below the vacuum will be released automatically Hold the beaker until the vacuum builds 5 The mixer switches on automatically for the set time When the time has expired an acoustic signal sounds 6 Take hold of the beaker before you switch off Fig 1 the master switch 1 vacuum After the vacuum in the beaker drops the beaker will no longer be clamped to the unit a WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 6 2 VACUUM MIXING with the WAMIX Classic 1 Set the mixing time with the timer 2 up to 240 sec automatic mixing this remains the default until a new time is set For manual mixing turn the timer to O and set the desired mixing time after a vacuum is present 2 Place the mixing materials in the beaker and mix well by hand until the powder is well mixed with the liquid Seal the beaker with a lid Insert the beaker in the unit from below the ps om vacuum will be released automatically Hold the beaker until the vacuum builds Fig 2 5
5. MIX Injector only 560108 Cap for rotary knob black WAMIX Injector only 380069 Seal D56 x D46 x 4 white self adhesive one side 560111 Cap for black knob with white stripe 560112 Black knob with white stripe 582002 Fuse2A T 250V D5x20 610025 ointered filter for vacuum 610028 Sound absorber WAMIX Injector only 13 WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor Beaker extra small 75 ml not supplied Adapter or Inceram VITA not supplied 320026 Compressed air hose blue D8 x 6 2 m WAMIX Injector 8 5 Repairs Servicing or repairs to the unit must only be carried out by trained technicians Only original spares are to be used Responsibility for the product is voided if unauthorised persons alter it or if inappropriate components are installed 14 WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor 9 Technical data 171987 WAMIX Classic vacuum mixer Voltage Power consumption Output Speed Mixing time Vacuum Safety class Overall dimensions Weight 230 V 50 Hz 1 A Si 2 A 150W 380 min up to 240 seconds adjustable approx 950 mbar IP 22 Width 205 mm Height 365 mm Depth 295mm 11 8 kg without wall mount 13 kg with wall mount 171986 WAMIX Injector vacuum mixer Voltage Power consumption Output opeed Mixing time Vacuum Compressed air connector oafety class Overall dimensions Weight 230 V
6. N Die Basis f r Ihr Labor Information n This symbol draws your attention to specific features that must be observed 2 2 Safety guidelines This equipment is designed to operate at 230V 50 Hz Make sure it is A always connected to the appropriate power supply Always remove the plug from the power socket before undertaking maintenance or cleaning work A locking hook underneath each unit prevents it coming loose once it has been mounted in the bracket Allow the condensers to discharge before opening the unit 2 3 Responsibility for operation or damage The responsibility for operating the unit lies exclusively with the owner or user if the said unit is incorrectly serviced maintained or altered by persons not employed by an authorised dealer or if the unit is used in a manner contrary to its specified purpose The unit must be maintained and operated in accordance with this user manual Wassermann Dental Maschinen GmbH is not responsible for damage arising from the nonobservance of these instructions Guarantee and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions il Ensure that this user manual is accessible at all times and has been read and understood WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor 3 Applications WAMIX equipment is used for mixing all kinds of plasters embedding media and silic
7. User manual Vacuum mixers WAMIX Classic Injector Wamix Classic Wamix Injector Die Basis f r Ihr Labor WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor Dear customer Thank you for choosing a product from the Wassermann range Wassermann dental equipment incorporates the highest standards of quality and the latest technology In order to enjoy maximum performance and years of trouble free operation please read this user manual carefully before you start work and operate the unit according to the recommended guidelines Please keep this user manual in a safe place where it can be referred to at any time Company address Wassermann Dental Maschinen GimbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 Email info wassermann dental com URL http www wassermann dental com Author Ap Date 14 06 2005 Version 1 WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor Table of contents TABLE OF CONTENTS KN KN KN KN KN KN KN KN KN KN KN KN KN KN KN KN KN KN KN KN EN EN KN 2 EECHER 3 2 FOR YOUR SAFETY c r rere rrr rrr rrr rrr rrr rrr nnn 3 2 1 FOLLOW THE USER MANUALE 3 2 2 SAFETY GUIDELINES cccccccccececccccceccccceccceccececcaceceauaceceaeaceneaeaceneaeaceneanseenss 4 2 3 RESPONSIBILITY FOR OPERATION OR DAMAGE ennemis iaa ee
8. e 4 OZEEE LNle xnenlmeee 5 4 BEFORE YOU START een 5 4 1 UNPACKING TRANSPORT nennen nennen 5 4 2 LOCATION STORAGE ccccceccccececccccceccccccececcacececuacececuaceteuaceneataceneauaceneansnenss 5 5 STARTING THE MIXER NNN NENNEN ENNEN ENNEN ENNEN ENNEN 7 6 OPERATING THE 7 6 1 VACUUM MIXING WITH THE WAMIX 8 6 2 VACUUM MIXING WITH THE WAMIX Case 9 7 ene e nnn nn nn nn nn nn nn nn nn nn nn nn nn nn nn 10 8 CARE AND MAINTENANCE ENKEN ENKEN EN EN EN EN EN EN 11 8 1 OE TANIN C 2 11 8 2 SERVICING 11 8 3 WARRANTY cccccececceccccccccceccaceccacececceceueaceneaueneaueaeeneaceneauecesneaeeeaueneaneassneas 12 8 4 SPARE PARTS AND ACCESSORIES 12 8 5 REPAIRS eege 13 9 TECHNICAL 14 10 EC COMPLIANCE CERTIFICATE enn ENNEN ENKEN e 15 WASSERMAN DENTAL MASCHINEN Die Basis f r I
9. hr Labor WAMIX is a manufacturer of vacuum mixers used not only for mixing all kinds of plasters embedding media and silicones but also designed for specialised dental procedures and for vacuum rinsing of prostheses When mixing silicones make sure that the beaker is only filled to the max height for silicone Otherwise silicone could penetrate the interior of the unit itself Units have separate drives for vacuum generation and for the mixing mechanism The mixer in the Wamix Classic and Injector versions can be switched off at any point by a time switch without breaking the vacuum Until changed the current preset mixing time up to 240 sec becomes the default for subsequent use An audible signal indicates the end of the mixing process The vacuum is guaranteed because the beaker on the Wamix Classic and Injector is held to the flange by the vacuum Mixers are supplied as wall units but can be converted for tabletop use at any time For accessories see 8 4 2 For your safety 2 1 Follow the user manual You should read and carefully follow the instructions in this user manual for setting up and operating the unit The unit is intended only for the specified purpose Especially important points are highlighted as follows Warning This is a warning of risk situations and dangers Failure to observe A this warning could be life threatening These warnings must be observed 4 ag WHSSERITIHI MEI DENTAL MASCHINE
10. ial use 1 2 Check that the mains voltage and the voltage requirements of the mixer are the same then plug in the power cable Only for WAMIX Injector Install a compressed air line in accordance with the technical data Be sure to use the correct hose size if the line is long inside diameter min 6 mm Provide a servicing unit for each line and use a pressure regulator to maintain a constant pressure il Accidental mixing is not possible because the motor cannot start until the beaker is held to the rim by the vacuum The mixing time also needs to be set Before you start your vacuum mixer make sure that the safety hook under the unit has been turned through 180 should fit in behind the wall mount Pull the hook forwards using the slot then retighten the screw on the hook to prevent it coming loose Warning Use only beakers with the new curved seal 171708 When using the 115 V version you have to install the power pack Order no 171788 Therefore you plug in the conductor of the Wamix into the socket Pos 1 of the power pack The conductor of the power pack Pos 2 has to be pluged into the house socket In order to mount the power pack at the table stand please use the enclosed screws M6 WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor 5 Starting the mixer Switch on green master switch 1 vacuum mixing Open compressed air valve WAMIX Injector only
11. na anteriormente mencionada cumple con los limites requeridos por el reglamento EC Ahora bien esta declaraci n quedar invalidada en caso de realizar modificaciones al aparato sin nuestra aprobaci n Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven EU normen Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming wijzigen aan de machine worden aangebracht Place date Hamburg 14 June 2005 Company stamp Wilfried Wassermann Managing Director 16 WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor Notes 17 WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor Notes 18 WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN Wassermann Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 Email info wassermann dental com Internet http www wassermann dental com
12. ones under vacuum The vacuum can be as high as approx 920 950 mbar This unit is also suitable for vacuum rinsing of models for special dental procedures The insulating layer between the model and the prosthesis cannot separate prematurely because the model remains moister in the pressure embedding unit than when water is used 4 Before you start 4 1 Unpacking Transport Remove the packing materials and place the unit on a firm level surface or use the supplied bracket to mount it on the wall Check that all items have been supplied see 8 4 Before transporting the unit ensure that it has been unplugged from the power socket Make sure that it is packed correctly in order to avoid accidental damage 4 2 Location storage Place the unit on a flat surface where it is to be used or mount it on a wall f mounting on a wall ensure that the wall is strong enough to support the unit Detach the wall mount from the unit and use it as a template for drawing a drilling scheme to drill the 8 mm diameter dowel holes Leave at least 30 35 cm free space beneath the unit Always mount the unit allowing sufficient room for working and servicing see dimensions do not set up out of doors f the unit is to be stored for an extended period protect it from moisture and dust ap WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor he following connections should be in place before init
13. y normal cleaning sponge damp cloth mild detergent no chemical additives Solvents must not be used to clean the front panel Keep the beaker clean When not in use fill with water to just below the mixer The model plate must always be legible and should not be removed 8 2 Servicing n Allow the condensers to discharge before you open the mixer Our vacuum mixers do not require servicing Make sure the unit is kept clean and that the rim seal for the beaker vacuum seal is not damaged Changing the filter Remove screw 1 on the left near the mixer mechanism on the rim under the unit The filter swings loose at the forward end of the screw After changing the filter do up the screw finger tight do not forget the O ring 12 WASSERMAN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 3 Warranty The warranty period for our instruments is 12 months If faults occur within the warranty period contact your dental depot or get in touch directly with our Service department Vacuum mixers should only be operated in perfect condition If faults occur which could harm operators or third parties the unit should not be used until it has been fixed The warranty does not cover damage caused by improper use external mechanical causes transport damage or interference with the unit by unauthorised persons 8 4 Spare parts and accessories 511161 Rocker switch green IP65 560107 Rotary knob black WA