1. example We have an emergency at lt your address gt please call 911 immediately if you want to play back the recorded message then press 6 on the main panel to hear it 1 To add a cell phone or any landline number to the system enter password 1 2 3 4 till you see out and home lights are on i e in setup mode then press command 31 XXX XXX XXXX To add another use 32 instead of 31 and so on up to 36 38 and 39 are reserved for telephone numbers of monitoring centers if you have any To remove a number from the list of numbers to call in case of an alarm simply enter the command without a number For example to 6th number then press 36 Operation Diagram Input password default 1234 Alarm Phone No Settings 31 Ist User phone number 32 2nd User phone number 33 3rd User phone number Record Voice Message 34 4th User phone number Record voice Replay BEWARE Delete ALL Sensors Register 35 Sth User phone number voice sensor 36 6th User phone number message message the with system Ba cd 38 Ist monitoring center 39 2nd monitoring center Set each sensor to different defense zone so you can tell which sensor was triggered from the message on the LCD To code a sensor to zone 2 for example Ensure all sensors are OFF including the sensor to be programmed to zone 2 and ensure that all gap d
2. delay type as follows 1 Instant Zone 2 Delay Zone 30 seconds delay 3 Emergency Zone 24 hours will sound off regardless of system armed or disarmed 5 Home Zone 0 Disable zone Example To set the second defense zone to be Home zone input 0 2 25 Recommendation Set door window sensors as Instant zone The sensor in those area will activated to send signal to main panel immediate if detect any change Set wireless IR Motion Sensor as home zone it will enable only in OUT ARM mode disable in HOME ARM mode when you are at home set HOME ARM all window door sensor are protect your house but the motion sensor will not disturb you You can set the door sensor at the main door as Delay zone if you do not want to take remote controller when going out In this case you can disarm the system in 30 seconds after open the door but the alarm system will not activate during this period 11 Turn on off Forgot To Arm System warning If you turn on this warning for an entry or an exit zone then the system will beep three times to remind you to arm the system before leaving Use the following commands to turn it on and off ZZ71 for ON where ZZ is the entry exit zone doors Do this for all such zones ZZ70 for OFF default 12 Turn on off the function of anti interference When turning on the function of anti interference in arming status it will activate siren to alarm not calling users i
3. gt lt gt Place the control panel and all parts and accessories out of children s reach Keep the alarm system dry Rain humidity and various fluids or moisture all will corrupt the electronic circuit Do not use or place the alarm system in dirty locations otherwise the electronic elements will be damaged Do no place the system in excessively hot locations High temperature will shorten the service life of electronic equipment damage batteries deform or even melt some plastic parts Do not place the system in excessively cold locations Otherwise condensation many occur and damage the circuit board of the alarm system It is recommended that you check and test the alarm system periodically Check the main unit every three months i 2 3 4 Whether it can arm disarm normally Whether it can dial the number for alarm normally Whether it can receive wireless detectors signal normally Whether the back up battery can work normally Check the wireless detectors once a month 1 2 3 Trigger wireless detectors to see if system can alarm normally Check all detectors batteries to see if it s in low voltage Check whether wireless detectors can send signal to the main unit normally Since the alarm system is continuously in operation or standby mode the supply adaptor of the control panel shall be connected to a safe and reliable socket Do not place the system near your bedroom or office table because the
4. 05 to trigger your second door sensor and so on for all sensors When done press return key to exit setup mode Disconnect controller panel from power adapter 4 Installation of Control panel and keep the place where you like defense zone indicator a Sy i E E oo out home Be l j i ANCAS S ae 2 C3 out i _ CAA r oe i M a 5 4 i 3 6 hom Ik fay OAAS GO eee ee disarm r8 a E 3 k t Connect the mini siren to the controller panel SIREN port Connect a phone cable from the wall to the OUT LINE port on the controller panel and connect a phone cable from the TELEPHONE port to your landline phone Connect the power adapter to the system and switch it ON the power status will be blinking and sound beep which shows the control panel works normally It will sound three beeps every 30 seconds which helps users remind of setting alarm phone numbers The sound beep will disappear when you finish the alarm phone number setting even you have no land line please pretend to set any number to void the beeps if you feel annoy Record alarm message To record an outgoing voice message to be played out in case of alarms enter setup mode and use command 6 and start talking immediately until the counter down reaches 00 Every recorded message will replace the last message The message should be short and clear For
5. 2 wireless defense zone display 1 to 32 and 7 wired defense zone display 91 97 Every defense zone can set independently arm disarm delay alarm and so on Have the function of one key arm User can start Home arm or Out arm freely by keeping pressing one key on remote control Can set the reminder sound of defense zones Will remind users of remembering arm the alarm system when going out Can work with other products of our company Such as wireless black outdoor siren WSR 01 and mini siren lt stores 3 groups of monitoring center and 6 groups of user phone numbers to dial out and play the recorded message if there is an alarm 10 Can arm disarm with remote control or keypad on the control panel 11 Can arm disarm listen in by calling the host phone number The phone numbers of control panel 12 Have the function of reminder for circuitry failure For example if telephone line is cut or short the control panel will alarm 13 Have the superior of connection 14 Have in built backup battery and can continue to work and last for 24 hours when electricity is cut or in failure 1 Install battery to all door sensors Es Step 1 Open cover Step 2 Install battery Step 3 close cover q _Pisacrea BT Step 4 keep two parts touch each other 2 Install all 9V battery to IR motion sensor keep switch off 3 Connect control panel to an outlet using the included power adapter and switch it
6. DisEcror PiSector Home security systems User Manual ALM S02 Read manual fully before use PiSector Inc USA www pisector com Thank you for purchase this alarm system For proper use and your safety please read these instruction thoroughly and carefully before you put the system in use Keep this manual carefully for your reference in the future Commands Description Command Remarks Change password 10 PPPP PPPP is new password default 1234 Arm the system in OUT mode hold the OUT key till beep AAI ANO RENSET ANA CA ROEE AGES are armed Arm the system in HOME mode hold the HOME key till beep Only exterior detectors are armed Disarm the system PPPP then DISARM PEE IS PASSWOTO OPIRU IAA Don t press or you ll enter setting mode Enter Setting Mode PPPP Program or PPPP PPPP is password default 1234 Exit Setting Mode Return then Return Return to operational mode Add phone number to the notification 31 36 NNN NNN NNNN NNN NNN NNNN Is a 10 digit phone cell or queue to call them in case of alarm landline number without 1 at start Add monitoring center if you use one 38 39 NNN NNN NNNN Don t set if do not have a monitor center Record outgoing voice message Give address and ask for help or calling 911 Replay outgoing voice message 6 Will be played to numbers in the queue 01 03 IR sensors 04 07 Smoke Fire Water detectors Code a wireless detector to zone ZZ 7 ZZ 09 Panic Button 08 16 Gap
7. ceiving distance you should pull the antenna and make it upwards c if the low power indicator is on please change the battery 6 Installation of Wireless PIR motion Sensors PIR motion sensor are used to detect the movement within a certain range Fix the adjustment bracket on the wall with the provided screws and attach the detector to the bracket it is recommended to mount at a height of 6 5ft to 7 2ft above the floor Effect of the PIR motion sensor is best when the detection direction is 90 degree angle with the walking direction of the intruder Choose the most suitable installation place and angle according to actual situation and taking the following installation diagram as reference to ensure the detection effect is best Please do not fix it under direct sunlight or other strong lights and also keep it away from places with frequent strong air steam or air condition Window coor If the low power indicator is on please change the battery 7 Wired detectors if you have exist At the back side of the host there is a wired connector which can link with 7 wired detectors The 12V and GND are to connect with the power supply the COM is the public port When using the wired detectors Connect the 12V and GND to the power supply connect one line of the wired detector to the COM and the other to 1 or 2 or 3 or 7 8 N q Zone 91 the Ist wired detector Zone 92 the 2nd wired detec
8. d HOME light on then enter code comment 7 enter zone number 05 you will see 05 display on the main panel press test button on the smoke detector which next power light you will hear two beeps from main panel like you add door sensors and a test sounds from smoke detector then press return key on the main controller Step4 Enter password 1234 at your PiSector Alarm System main controller ALM SO2 you will see OUT and HOME light on then press 0523 you will hear two beeps then press return this is step for set zone 05 as a emergency zone regardless of your system arm or disarm when smoke detector triggered system goes off immediately advice set only for smoke detector CO detector or panic button detector Typical house configuration External Sirens Doorhaindea wz Garage ii PrF F a a Sh Smoke ses FIR hdowem ent Detector Detectors The following sensors are optional e Wireless Outdoor Siren with flash o Signal Repeater Wireless keypad I amp ee Glass Sensor Panic Button Remote Controller i X NU P 4 Wireless Smoke Gas Detector Wireless Pet Detector Immune PIR Detector 7 Optional sensors available You can choose according to your specific requirements 2 Technical Parameters Main Panel Power Supply AC 220V 10 DC 9V Recharge Battery Ni MH DC 7 2V Working Current lt 50mA Alarm Current s lt 300mA Wireles
9. detectors 30 32 Remote controllers Delete ALL wireless detectors DON T DO THAT unless you must ZZ 01 08 wireless 91 97 wired 09 32 are instant zone can t change X is zone type 1 instant windows 2 delay doors Change delay mode or zone type ZZ 2 X 3 emergency fire smoke water panic 5 home IR sensors 0 disabled or move battery Forgot To Arm System warning where ZZ is entry or exit zones Remote controller arm disarm tone annoying turn it off Anti interference so no one can jam the communication between sensors and main unit 483MHz frequency 17 1 N N Anti decode so on one can decouple 18 1 your sensors from the main unit N F O RR 00 12 default 00 answer immediately 1 Arm 2 Disarm Telephone line cut or short circuit alert Ringing times before system answers call waiting for remote commands Siren sound duration 12 RR Listen In for 30 sec or till press 1 2 or Exit stops calling other numbers in the queue if system called you Siren sound duration 29 MM MM 00 30 minutes default 01 minute Factor Reset 0000 Lose all coding inc remote controllers Features 1 D OE ow ee Anti interfere function When someone interferes it with same frequency the control unit will activate siren to alarm Support anti decode with remote control Digital LED Defense zone display Users can know which defense zone is triggered 3
10. etectors have no gap between their two parts close doors windows Input1234 to enter setting mode Input 7 0 2 to add sensor to zone 2 Switch ON the sensor or if a gap detector then separate the two parts to trigger it The system should sound 2 beeps indicating that the system has recognized this sensor Switch OFF sensor or bring back the two parts of a gap detector to continue coding other sensors Attention Try to install the control unit in the center of defense zone and pull antenna and make it up for getting more wireless receiving distance Installation position should be far away with huge metal objects and wireless device Connect the trunk line with control panel in order that it can dial out in the first second when there is an alarm Should be installed in a shelter 5 Installation of door sensors Door sensors are used for detecting the status of open and close of windows and doors It will detect it and send the signal i less then 1 2 inch to control panel a Tear apart the double side adhesive tape on the magnet small piece and the transmitter Larger Piece then adhere them to the appropriate position stronger recommend fix it again with super glue or screw to avoid it fall down in floor Caution Magnet should be close to near to the side of transmitter with indicator The two should align with each other and the distance should not exceed 1 2 inch b In order to get the best re
11. f Someone interferes the alarm system with the same frequency for more than 20 seconds Command On 17 1 Off 17 0 System default Off 13 Turn on off function of anti decode In order to prevent people from decoding the alarm system it is recommended to turn on this function Disarm only by the keypad will not disarm by remote controller Command On 18 1 Off 18 0 System default Off 14 Turn on off the reminder for phone line trouble It will warn you if the phone line is cut or short circuit It will sound three beep every 10 seconds during disarm status and siren goes off during arm status 15 Set the ringing times for telephone Call the main panel after the ringing circle the main panel will active automatically then you can remote control the alarm system follow prompt E g set the ringing times as 04 then you dial the number of the main panel you will hear prompt from main panel after 4times rings please do not connect with a auto answer machine Command 12 X X X X shows times of ring from 00 12 OO means the main panel will not active and you aren t able to remote control the system System default is 00 16 Set the alarm time of siren You can set alarming time of the siren according to the user s request from 0 to 30 minutes Command 2 9 X X X X is 00 30 minutes System default 01 minute 17 Turn on off the warning tone of remote controller Turn on this function the siren will ma
12. he siren power adapter 12V 0 5A to the DC port of wireless black siren 4 Connect and disconnect the siren from the power adapter connector 3 times in succession so it beeps 3 times Hint first connect you will hear a short beep then disconnect second time connect you will hear a short beep then disconnect third time you will hear 3 short beeps Now the siren is in the coding status 5 Press Emergency key once on the main panel console the siren will beep once Now the siren is recognized by the main unit and the coding is successful 6 Then disconnect the siren from the power adapter connector waiting for 10 seconds and switch off the main panel waiting for 10 seconds too 7 Test Connect the siren power adapter 12V 0 5A to the DC port hear one beep switch on the main panel press emergency key once the black wireless siren will goes off Now you can remove the adapter and mount the black siren outside of house where you like wireless siren to main panel range about 50 80ft wireless Siren 26 Add Smoke Detector Step 1 Before you code the smoke detector to system first set up the communication jumper to DO at L and D1 at H please look follow diagram THU i _ i Al ee DO o oe e o D3 Connect the jumper as above red arrow position Step2 close the cover install battery Step3 Enter password 1234 at your PiSector Alarm System main controller ALM S02 you will see OUT an
13. ke a short beep each time when you press the remote controller Command On 8 Off 8 system default On Factory Reset Reset will delete all registered coded information include password which you changed All settings will return to the default status Command 0 0 0 0 18 Operation Instructions Homea 19 Out Arm Press in remote controller or pressing the key OUT on the panel for 2 seconds with the status LED flashing take 30 seconds when the OUT indicate light stop flashing change to a solid yeller light the system will enter into the mode of Out Arm and all the detectors will be enabled 20 Home Arm Press Home arem button in remote controller or keep pressing Home for 2 seconds with the sound beep the Home indicator light on the main panel will flashing the system enter Home Arm mode all home zone sensors inside house which you set as home zone sensors will disable so that you can move in home freely but others instant sensor which for door window or garage still enable if intruder come system will give you call and siren goes off 21 Disarm Press 6 on remote control or input password DISARM on control panel the system will disarm 22 Emergency When there is an emergency press the Emergency button on remote controller or the main panel the system will alarm immediately no matter it is in arm or disarm status Note Please wait 10 seconds or
14. of remote controller is rusty 2 Low power battery Clean the rust 2 Change battery Light indicator of door sensor and PIR is Low power battery Change battery always on Dial alarm number The main panel has stored Set it again according to the operation slowly other numbers manual 1 Low power battery in the accessory The main panel 2 There is block between the 1 Replace the battery cannot receive control panel and the wireless 2 Pull out the antenna of the accessory and signals from the accessory or the distance the main panel and adjust the position accessory between them is too far 3 Code it to the main panel 3 The accessory has not been coded to the panel 1 Telephone line connection 2 Hasn t setup user number 3 Hasn t record 10s voice message Alarm panel makes beep sound continuously 1 Connect telephone line again 2 Setup user number 3 Record 10s voice message
15. on wait for 5 seconds till the main system start properly then enter setup password 1 2 3 4 on control panel and wait for the Out and Home indicators to light up indicating that you are in Setup mode ready to code all wireless sensors and remote controllers Hint 1 If you do not press any key for 30 sec the unit will auto exit so re enter the password 1 2 3 4 again Hint 2 To trigger a door sensor move the two parts apart until their red light then return the parts back so they don t interfere with the coding of other sensors i j Hint 3 To trigger a motion sensor switch it on till you see a red light then switch it off Hint 4 To trigger a remoter controller press any one of buttons on the remoter controller Hint 5 To trigger a panic button press the red button till you see a right light on then release the button Hint 6 Please press m to make the system disarmed to avoid it activate the siren to alarm when registering sensors While in setup mode press command 7 you will see 01 displayed i e Ready to code zone 01 then trigger your first remote controller You should hear two short beeps indicating that this remote controller has been coded then press 02 to trigger your second remoter controller after you hear two beeps then press 03 to trigger you third remoter controller after you hear two beeps then press 04 to trigger your first door sensor after hear two beeps then press
16. s Receiving Frequency 433MHz 0 5MHz Wireless Receiving Sensitivity 5mV m Anti jamming Intensity 1V m frequency range 20 1000 MHz Outside Alarm Siren 110db Working Condition Temperature 10 C 40 C Relative Humiditys90 Detector Capability 99pcs Wireless Door Window Detector Battery 12V 23A Static Current lt 20uA Transmission Current lt 15mA Transmission Frequency 433MHZ 0 5MHZ Wireless Range No obstacle 150feet Gap Distance 1 2 Inch Working Condition Temperature 10 C 40 C Humidity lt 90 Wireless PIR Detector Battery DC 9V Static Current lt 100uUA Transmission Current lt 20mA Transmission Frequency 433MHZ 0 5MHZ Wireless Range No obstacle 200m Detective Speed 0 3 3m s Detective Distance 15ft to 25 ft Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 C 40 C Humidity lt 90 Remote Controller Power Supply DC 12V built in 12V battery Static Current 0 Transmission Current 15mA Transmission Frequency 433 0 5 MHz Wireless Range No obstacle 150feet Working Condition Temperature 10 C 40 C Relative Humiditys90 28 Care and Maintenance The alarm system has excellent design and used advanced technologies It shall be used with care The following suggestions are required to maintain your obligations under the warranty terms and for prolonging the service life of the system lt gt lt gt lt gt lt
17. siren will make high loudness sound in the case of alarm which may adversely affect your rest or work If the alarm system will not be used for a long time please disconnect the system from the power supply Please do not disassemble repair and alter the products without permission or it may cause accidents and faults Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages Without approval and consent of relevant authorities please do not set 110 119 or the alarm phone number of police station for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send it to the dealer or authorized service point for repair We will try our best to solve the problem for you as soon as possible 29 Troubleshooting Possible Causes Possible Solutions 1 Hasn t armed Less than 30 seconds after arming Set wrong phone number The two parts of door window sensor are installed too far from each other Hasn t activated PIR Hasn t checked code Arm the unit Operate 30 seconds later Set the number again according to the manual Adjust the installation place of the door sensor Activate the PIR Check code again Cannot alarm by phone Remote controlling distance is too short and the light indicator is not bright enough 1 The battery
18. so repress disarm and enter into next operation It needs time to be activated again 23 Receiving Alarm Call When there is an alarm the siren will goes off the alarm indicator light on the main panel will light up the defense zone indicator will display the number on LCD and the system will make alarm call to your authorization pre saved number After answer the call user will hear the recorded message and then can do the following operations Press for listen in 80 seconds Press to confirm that you have received the alarm and system will stop to call you and others on the queue if any siren will off sounds If you do not input the alarm system will continue to dial out all authorization pre saved phone numbers one after the other 24 Remote control You call the main panel to remote control the system after dial the number you will hear a long beep then input password follow by if the password is correct you will hear beep twice if wrong it beep four times Then you can control the main panel with following commands Press 1 to arm Press 2 to disarm Press to listen in Press to EXIT Note The system will hang off automatically if passwords are wrong for 3 times or no command received within 20 seconds 25 Add Wireless Siren WSR 04 Coding Setting up the Wireless Siren 1 Connect the main unit power adapter 12V 0 5A to the DC input port 2 Connect t
19. tor Add or Delete Door Window Sensors or Motion Sensors Each detector has its unique ID It must be coded with the main panel for normal working If it is not coded with main panel the main panel would not identify it and could not receive the signal so the alarm will fail If you want to add more wireless sensors late please refer to the instruction as follows input password 1 2 3 4 in the main panel to enter setup mode press command 7 you will see 01 displayed then think a zone number which you have not use yet e g 20 input 20 then trigger the new sensor which you want to add you will hear two beeps mean you have identify code the new sensor to the system if you have more you can continue to code another zone as above step after finish all code then press return to exit setting status Delete Sensors to delete a sensor simply code another sensor over its zone To delete ALL sensors then in setup mode use command 7 you will hear beep twice then all sensors will be deleted Change Password Command 10 new password new password must be 4 digits this password is used for remote control e g you use you cell phone or other phone to call system 10 Alarm Delay amp Zone type Setting You can set the type of defense zone according to your needs The system default is instant zone for all zones Only wireless zone 01 08 and wired zone 91 97 can be set Command ZZ2X where X is zone