Home
3 - ADT
Contents
1. 15 DO AUAN EE 15 5 9 Arming with Entry Exit or Follower Zones Vuolated 16 De O ONC COPA MING EE 16 O Zone BY DASSING ME 16 6 1 To BypassaZOne mmrrnrnrverrnnnrevrrnnrrevnrnnnrrnnnnnnnrennnnnsnennnnssnennnnn 16 6 2 To Un Bypass Nesen 18 7 Disarming the System rrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnvennennnnnnnnnnnnnr 20 7 1 Disarming with a User Code nas 20 7 2 Disarming a Partition from a Master Keypad 21 7 3 To Disarm with a Key Switch or Remote Control 21 8 Emergency Situations sssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nna 22 ANN 22 8 2 Panic Alarm EE 22 993 MENN 23 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 3 84 Duress COCO EE 23 9 0 Emergency Evacuation Plan ss nnnnnnnnnnnnnnvnnnnnnnnnevnnnnnnnnnnnerr 23 10 System Memory EN 24 10 1 Alarm Memory ENEE 24 TL D e E 24 11 1 Entering New Changing Existing User Codes 25 11 2 Deleting User Codes LED Keypad rrrrvnrnrrrrnnnnnnnrnnrvvvenvrnnnnnnn 27 113 Maido OOS eegen 27 KEE 27 12 1 To Program Stay ZONES rrnennnenrrrnnnnnnnnnnvnnvenrrrnnnnnnnnnsennennvnnnnnnnn 28 12 2 To Cancel the Stay Zones erre 29 13 BUZZ Le 31 13 1 To Program Buzz e 31 13 2 To Cancel Buzz Zones tivsscsicccsvancentisaxassccnzeecsetealevexiensdsseteceseseave 33 14 eZ 35 14 1 To Program the Chime Zones erre 35 14 2 To Cancel the Chime Z
2. Press the MODE menu gt key ZONE 1 E FOR BUZZ ZONE ARM TROUBLE Use the MODE menu gt and Fire lt menu keys to scroll to the buzz zone you wish to cancel e g zone 3 ZONE 3 x TO DESELEGT ARM TROUBLE Press the x key to cancel the buzz zone ZONE 3 FOR BUZZ ZONE ARM TROUBLE Repeat steps 3 and 4 until required buzz zones are cancelled Press to exit the Buzz Zone Mode ZONE MENU ARM TROUBLE Press to exit the Zone Menu MAIN MENU ARM TROUBLE Press to exit the Main Menu 01 01 99 READY ARM TROUBLE IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 14 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated the siren will NOT sound and no alarm condition will be reported EXAMPLE You wish to know when someone enters or exits the front door the keypad will beep each time the door is opened if that zone is programmed as a chime zone 14 1 To Program the Chime Zones 2 ZONE NUMBER x 1 Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash to show that the panel is In the chime zone programming mode 3 To program a zone as a chime zone press the key corresponding to that zone followed by the x key 4 Program any other zones you wish to select as chime
3. Users Guide to Keypad Functions MANUAL NO 700 171 01B ISSUED AUG 2002 VERSION 1 18 Summary of Operation Forced Answer by Panel Hold down MODE for 1 second PARTITION NUMBER x Hold down 9 for 1 second ZONE NUMBER e Hold down 2 for 1 second ZONE NUMBER x Hold down 3 for 1 second ZONE NUMBER e Hold down 4 for 1 second ZONE NUMBER e View Trouble Status Hold down 7 for 1 second Duress DURESS CODE Change Partitions Bypass a zone Program chime zone Program stay zone Program buzz zone 2 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 GIES EE 5 Introduction to the IDS 1200 assssscasssssssiasecasisassasisnessniscacasocios 6 TA le 6 2 Understanding the LED Keypad Indicators 7 2 1 Notes on the LCD Keypad een 8 3 Operation of the LED Keypad rnunrnvvvvvnnnnnnnnnnnnnnnvnvnnvnnnnnnnunnnr 8 4 System information WE 9 4 1 PO METT rn 9 4 2 JSerGOdES uusssas a iemnianstssas geesde diker Se irge ege 10 43 Zone MON re le E 11 5 Arming THE EE TN 11 5 1 Away Arming Procedure e eeeeeeerreeeeeearenna 11 52 QUICK AW ay TL E 12 53 Stay rming ccccccccccsceseeeececeecesecccesseseneccceeeccccessseseeeeeeesssanes 13 54A Quick Stay AMING E 14 55 Stay Armand GO E 14 5 6 Arming a Partition from a Master Kevpad 14 5 7 Arming from a Key Switch or Remote Control
4. NO 700 171 01B ISSUED AUG 2002 VER 1 18 23 10 System Memory 10 1 Alarm Memory The Alarm Memory displays any zones which were violated or bypassed the last time the system was armed If the ARMED indicator is flashing before you disarm the system a violation has occurred To view which zone was violated disarm the panel and continue as indicated below To Display Alarm Memory 0 Hold down the key until the keypad buzzer sounds 1 Hold down 0 until the keypad buzzer sounds 2 The READY indicator will extinguish and the keypad buzzer will sound briefly 3 Flashing zone indicators show which zones were violated during the last armed period ZONE 4 AS VIOLATED ARM TROUBLE 4 The bypassed zones will have constantly illuminated indicators 5 The memory status will be displayed for five seconds or until the is pressed 6 The alarm memory will be erased the next time the system is armed 11 User Codes The IDS1200 Alarm Panel has 32 programmable user codes Code 1 Master User Code which is active in both partitions Codes 2 14 General User Codes for partition 1 Code 15 Partition 1 Maids Code Code 16 Duress Code for partition 1 Codes 17 30 General User Codes for partition 2 24 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 Code 31 Partition 2 Maids Code Code 32 Duress Code for partition 2 NOTE User Code 1 can change any user code from eit
5. a mistake press the key and re enter the code 5 The ARMED indicator will flash for the duration of the exit delay Any bypassed zones will be shown by a steady illuminated zone indicator 01 01 99 DELAY TIME ARM TROUBLE 6 The arming process has begun Leave only via the follower and entry exit zones 01 01799 AWAY ARMED ARM TROUBLE 0 5 2 Quick Away Arming 1 Hold down the key until the keypad buzzer sounds If this function is enabled it is possible to AWAY arm by simply holding down the 1 key until the keypad buzzer sounds and the arming process begins 12 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 5 3 Stay Arming USER CODE Do not leave premises This allows the user to arm the perimeter zones while disabling the interior zones so that it is possible to remain on the premises 1 Ensure that the READY indicator is illuminated if not check that all protected doors and windows are closed and that motion has ceased in the areas covered by motion detectors 01 01 99 READY ARM TROUBLE If necessary close the front door Press the key to cancel any unintended entries Enter a valid USER CODE DO NOT open the front door If the front door is opened the system will arm in AWAY mode 6 The ARMED indicator will flash for the duration of the exit delay ae Pe 01 01 99 DELAY TIME ARM TROUBLE 7 The AWAY indicator will remain extinguish
6. closed Bypassing a violated zone will also create a READY condition Does the siren sound before you exit The exit delay may be too short ask your installer to adjust the exit delay OR You have not left via a follower and entry exit zone or have strayed into an instant zone Either avoid these zones or ask your installer to change the zone type 16 3 Problems when disarming the system Does the siren sound immediately upon entry You have not entered via the entry exit zone or have strayed into an instant zone Does the siren sound before you get to the keypad You have strayed into a non follower zone OR You have taken too long to get to the keypad The panel will not disarm You may have entered an incorrect code Press the key first then re enter your user code 16 4 For Service Central Station Information Account Telephone Installer Information Account Telephone 44 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 Alarm MENN EE 5 7 24 38 40 d SE 5 7 9 11 15 16 24 27 43 MT eee ee en EE 11 12 ONC SE BEE 16 SOGNER E 9 12 38 40 MT nine 9 14 HAD eden 9 D er 5 9 13 14 29 31 38 41 42 Stay M amp GO gedet 5 9 14 38 42 AUO AMMING EE 15 PUY NOOD eebe 7 13 Bypass 5 7 12 13 14 16 17 19 24 27 28 38 40 41 44 o DO DETT EN 5 7 15 20 21 23 24 27 35 40 44 DECS ee hehe 10 23 24 25 uge ee E ie RE 23 219 lat EE R E EES
7. code Once the system disarms the ARMED indicator will extinguish and the keypad buzzer will stop sounding If no valid user code has been entered by the end of the entry delay period an alarm condition will be registered If the entry period is too short have your installer change the entry delay period If four incorrect user codes are entered consecutively the keypad 20 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 will be non responsive for 30 seconds NOTE If a strobe or flashing light has been installed and an alarm condition is registered the light will continue flashing after the siren has timed out Entering a valid USER CODE will cancel the strobe 7 2 Disarming a Partition from a Master Keypad Hold down MODE PARTITION NUMBER x USER CODE 1 Hold down the MODE key on a master keypad until the keypad buzzer sounds PARTITION ARM TROUBLE 2 Enter the PARTITION NUMBER you wish to arm followed by the x key 3 Proceed as if the keypad was assigned to this partition NOTE If the ARMED indicator remains illuminated the wrong user code has been entered Press the key and re enter your code Four successive incorrect codes will result in the keypad locking you out for 30 seconds During this time any code will be treated as incorrect 7 3 To Disarm with a Key Switch or Remote Control This option is not standard check with your installer to verify if thi
8. in a manner which does not permit bypassing e g Panic zones 6 1 1 Bypassing Zones using the LCD Keypad 1 Hold down the 9 key until the keypad sounds BYPASS MODE ARM TROUBLE 2 Press the MODE menu gt key ZONE 1 TO BYPASS ARM TROUBLE 3 Use the MODE menu gt and FIRE lt menu keys to scroll to the zone you wish to bypass e g zone 3 ZONE 3 TO BYPASS ARM TROUBLE 4 Press x to bypass the zone ZONE 3 x TO DESELEGT ARM TROUBLE 5 Repeat steps 3 and 4 to bypass any other zones 6 Press to exit the bypass mode IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 17 10 ZONE MENU ARM TROUBLE Press to exit the zone menu MAIN MENU Press to exit the main menu If multiple zones have been bypassed e g zones 3 and 5 the following will be shown on the LCD display Press the MODE menu gt key to view other bypassed zones 6 2 To Un Bypass a Zone 18 Hold down 9 ZONE NUMBER x Hold down the 9 key until the keypad buzzer sounds to enter bypass mode Press the number corresponding to the currently bypassed zone then press the x key IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 3 The zone indicator will extinguish the zone is now active 4 Press the key to exit the bypass mode 6 2 1 Un Bypassing Zones using the LCD Keypad 1 Hold down the 9 key until the keypad s
9. per system Quick Away Arm Quick Stay Arm Arm with Entry Exit or Follower Zones Violated Stay Arm Stay Arm and Go Siren Sound on Arm Disarm double toot arm short toot disarm Panic Alarm Fire Alarm Medical Alarm Chime Zones Buzz Zones Zone Tamper Monitoring Remote Arm and Disarm IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 9 4 2 User Codes User We User Code Uer Wan Paritton Foi 1234 Defaut Master Code 182 Do yen Mastercode tar elo o oo ae pp 4 sch oO CO IN N amp MMOL MO LMM MO MI P MY Oo OIRINN O Ce CA O Partition 2 Maids Code Partition 2 Duress Code oo NO 10 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 4 3 Zone Information Zone Zone Type e g Entry Exit Zone Name e g Kitchen door Part 1 Part 2 5 Arming the System There are various options for arming the system 5 1 Away Arming Procedure USER CODE Leave via Entry Exit Zone 1 Ensure that the READY indicator is illuminated if not check IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 11 that all protected doors and windows are closed and that motion has ceased in areas covered by motion detectors 01 01 99 READY ARM TROUBLE 2 If necessary close the front door 3 Press the key to cancel any unintended key entries 4 Enter a valid 4 digit USER CODE If you make
10. programmed the panel can be armed even if there are violated zones This means that a monitored window can be left open or other zones can be violated and the panel will still arm If the violated zone is then cleared the panel will still arm If the violated zone is then cleared the panel will resume monitoring the zone hence causing an alarm condition or initiation of an entry delay as appropriate if violated 6 Zone Bypassing a The term BYPASS is used to describe a zone that has been de activated i e violation of a bypassed zone will not cause an alarm tis used when access is needed to part of the protected area while the system is armed e Zones cannot be bypassed once the system is armed e Bypassed zones are automatically cancelled each time the system is disarmed and must be re bypassed before the next arming 6 1 To Bypass a Zone Hold down 9 ZONE NUMBER x 4 A oe oe 1 Hold down the 9 key until the keypad buzzer sounds to enter bypass mode 2 Press the number corresponding to the zone you need to by pass e g the 2 key if you wish to bypass zone 2 then press the x key 16 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 3 Therelevant zone indicator will illuminate to indicate that the zone is now bypassed 4 Repeat step 2 to bypass any other zones 5 Press the key to exit the bypass mode NOTE Some zones may be programmed to function
11. that any other code i e not a maids code has been used to arm the system entering the maids code will not disarm the system 12 Stay Zones Stay zones are those zones which are bypassed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as bedrooms or other areas which require access must be bypassed Stay zones need only be programmed once Each time the IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 27 system is armed in the stay mode the pre selected stay zones will be bypassed automatically 12 1 To Program Stay Zones 4 5 3 ZONE NUMBER x ff Hold down the 3 key until the keypad buzzer sounds Press the NUMBER corresponding to the zone you wish to be a STAY zone followed by the x key The relevant zone indicator will illuminate Buzz zones will be shown by flashing indicators See Section 13 A Buzz zone cannot be selected as a Stay zone the Buzz status must be cleared first Repeat step 2 until all stay zones are selected Press the key to exit the stay zone programming mode 12 1 1 To Program Stay Zones LCD Keypad ale 2 3 28 Hold down the 3 key until the keypad buzzer sounds STAY ZONE MODE ARM TROUBLE Press the MODE menu gt key ZONE 1 FOR STAY ZONE ARM TROUBLE Use the MODE menu gt and Fire lt menu keys to scroll to the zone you wish to be a stay zone e g zone 3
12. 171 01B ISSUED AUG 2002 VER 1 18 2 Understanding the LED Keypad Indicators Refer to illustration on inside front cover of manual 1 ARMED Indicator Red llluminated Partition Armed Extinguished Partition Disarmed Alarm Condition or Memory Entry Exit Delay Flashing 2 AWAY Indicator Red llluminated System Armed in Away Mode Extinguished System Disarmed Stay Mode TROUBLE Indicator Red llluminated Trouble Condition Extinguished No problems with partition or system ES 4 READY Indicator Green llluminated Partition is ready to be armed ZONE Indicators Yellow lluminated Zone bypassed S Extinguished Flashing Zone violated IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 7 2 1 Notes on the LCD Keypad Refer to illustration on inside back cover of the manual 01 01 99 READY ARM TROUBLE The illustration above shows what text is shown on the LCD display as well as the status of the ARM and TROUBLE indicators Below is a key showing the three possible states of the indicators and the symbols used to represent them Extinguished O Where procedures followed for programming functions are the same for the two keypads illustrations showing the LCD display and indicator status will accompany the text directions for the LED keypad Where procedures vary between the keypads the directions and illustrations for the LCD keypad procedure will follow
13. 43 EN ETP mesen 7 9 11 13 14 15 20 NICE 5 6 9 22 23 42 Keypad Buzzer 8 9 12 14 16 17 18 20 21 22 23 24 25 28 SE 29 30 31 32 33 35 37 36 40 41 43 EOD ee o 17 19 25 27 28 30 32 33 99 37 38 PED ege ees 7 8 27 KON eege DRE RR RR A i ia 15 21 Maids COGS air da punido brio REEE OE EE a ENAERE 10 24 25 27 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 45 Master Keypad narre 14 15 21 Master User Code aa 10 24 25 26 Medical asa ste cmp v a dp di AE EAER ERRARE ELENEN AFET 5 9 23 Seite 5 9 22 PAIN E 7 9 14 15 21 24 25 43 VL Fe 24 25 27 See 24 25 27 Reset Fire Sensor rara 38 42 SWO EE 9 15 21 22 35 44 TAG O GE 21 22 SE NOG geben Eeer 7 28 EO EEN 38 42 Trouble Condition EE 7 9 40 43 Trouble ee TEEN 43 User Code 10 11 12 13 14 16 20 21 22 24 26 27 EE 31 38 40 41 42 Zone PU epee eee 9 28 31 32 33 34 38 41 ONIME E 9 35 36 37 38 40 41 EN E 5 9 12 14 16 20 44 FOG WEEN 5 9 12 14 16 44 Ier EE 5 44 a e 17 SEE 5 13 14 27 28 29 30 32 38 41 46 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18
14. Memory 1 Trouble 2 Violations 3 Bypassed Zones 1 Quick Arm 2 Program Zones Zone Menu 0 Chime Zones 1 Stay Zones 2 Buzz Zones 3 Bypass Zones 4 Zone Names 3 Assign User Codes 4 Set Date and Time 5 Stay Arm 6 Stay Arm amp Go 7 Reset Fire Sensor 8 Answer Phone To Exit Menu IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 39 15 2 View Menu This menu option allows the user to view the status of zone and panel conditions 15 2 1 Alarm Memory Shortcut key 0 The Alarm Memory displays any zones which were violated or bypassed the last time the system was armed See page 24 for additional information on Alarm Memory 15 2 2 Trouble Shortcut key 7 In the event of a trouble condition the trouble indicator will flash See page 43 for additional information on viewing trouble conditions 15 2 3 Violations This menu options allows the user to view the currently violated zones 15 2 4 Bypassed Zones This menu options allows the user to view the currently bypassed zones Shortcut key 1 The Quick Arm function if enabled allows the user to arm the panel without having to enter a valid USER CODE 15 4 Program Zones Zone Menu This menu option allows the user to change zone modes 15 4 1 Chime Zones Shortcut k
15. ROUBLE 2 Press the MODE menu gt key ZONE 1 FOR CHIME ZONE ARM TROUBLE 3 Use the MODE menu gt and Fire lt menu keys to scroll to the chime zone you wish to cancel e g zone 3 ZONE 3 x TO DESELECI I ARM TROUBLE 4 Press the x key to cancel the chime zone ZONE 3 FOR CHIME ZONE ARM TROUBLE IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 37 5 Repeat steps 3 and 4 until chime zones are cancelled 6 Press to exit the Chime Zone Mode ZONE MENU ARM TROUBLE 7 Press to exit the Zone Menu MAIN MENU ARM TROUBLE 8 Press to exit the Main Menu 01 01 99 READY ARM TROUBLE 15 LCD Keypad Menu Navigation 1 To enter the Main Menu hold down the x key until the keypad buzzer sounds 2 Use the MODE menu gt and Fire lt menu keys to scroll through the menu items and press x to select a menu item 3 If entering the View sub menu or Zone sub menu use the MODE menu gt and Fire lt menu keys to scroll through the menu items and press x to select a menu item NOTE Please see overleaf for diagram illustrating the LCD key pad menu structure 38 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 LCD Keypad Menu Structure MODE MODE Use menu Use menu gt SA to scroll amp lt Tenjto scroll Ep select 30 ho select item item Main Menu View Menu 0 Alarm
16. ZONE 3 FOR STAY ZONE ARM TROUBLE IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 4 Press the x key to make the zone a stay zone ZONE 3 x TO DESELECT ARM TROUBLE 5 Repeat steps 3 and 4 until stay zones are selected 6 Press to exit the Stay Zone Mode ZONE MENU ARM TROUBLE 7 Press to exit the Zone Menu MAIN MENU ARM TROUBLE 8 Press to exit the Main Menu 01 01 99 READY ARM TROUBLE 12 2 To Cancel the Stay Zones 3 ZONE NUMBER 1 If an area programmed as a STAY zone will no longer be violated during STAY arming then the STAY status of such a zone should be cancelled This will allow the system to protect that area during a stay arm cycle 1 Ensure that the READY indicator is illuminated 2 Hold down the 3 key until the keypad buzzer sounds 3 Press the NUMBER corresponding to the STAY zone you wish to IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 29 cancel followed by the x key 4 Therelevant zone indicator will extinguish 5 Press the key to exit the stay zone programming mode NOTE The system will automatically exit this mode after 60 seconds 12 2 2 To Cancel the Stay Zones LCD Keypad 1 Hold down the 3 key until the keypad buzzer sounds STAY ZONE MODE ARM TROUBLE 2 Press the MODE menu gt key ZONE 1 FOR STAY ZONE ARM TROUBLE 3 Use the MODE menu gt and Fir
17. any needs to dial into the panel to change seitings or retrieve information 15 11 to Exit Menu 42 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 16 Trouble Shooting 16 1 Trouble Conditions In the event of a trouble condition the trouble indicator will flash 16 1 1 Viewing Trouble Conditions 7 Hold down the key until the keypad buzzer sounds If the TROUBLE LED is illuminated hold down the 7 key for two seconds to enter the TROUBLE viewing mode Refer to the table below to find the significance of each illuminated zone LED The system will automatically exit the TROUBLE mode after five seconds To clear the trouble condition press within 5 seconds of viewing Zone Trouble Condition 6 Auxiliary output 12V trouble N B If the zone 10 LED is illuminated contact your installer immediately Until an installer code has been entered the system will NOT arm 16 2 Problems When Arming the System Is the code correct If you enter the wrong user code there will be no response from the system Does the code belong to that partition Check the user code table to see to which partition your code is IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 43 assigned Is the READY Indicator illuminated If this indicator is not illuminated one or more zones are violated A violation is shown by a flashing zone indicator Ensure that all monitored doors and windows are
18. artition NOTE When arming from a master keypad the READY LED will not illuminate if there is a violated zone in either partition Should the violated zone not be assigned to the current partition arming of the current partition can still take place 5 7 Arming from a Key Switch or Remote Control This option is not standard verify with your installer which of the following options have been installed 1 Ensure that the READY indicator is illuminated before leaving 2 Leave and close the door remembering to lock 3 Press the remote button or twist and release the key switch 4 The alarm will arm immediately and the remote ARM indicator will illuminate OR If an exit delay has been enabled the exit delay will begin 5 If programmed to do so the siren will sound briefly verify with your installer NOTE lf a remote control is used it is advisable to have the siren sound on arm and disarm function enabled 5 8 Auto Arming Your system can be programmed to automatically arm itself daily at a preprogrammed time Ask your installer to program this function if required IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 15 5 9 Arming with Entry Exit or Follower Zones Violated The system can be programmed to arm even if the entry exit or follower zones are violated Follow the normal arming procedures i e Enter a valid USER CODE but it is not necessary to close the front door 5 10 Forced Arming If so
19. company To deactivate a zone When the panel is ARMED violation of a bypassed zone will be ignored To deactivate the system Fire medical and panic functions remain active while the system is disarmed A zone with a programmable time delay which allows the user to exit the premises after arming the system and time to reach the keypad after entering the armed premises This zone is generally the last exit point of the building and the first entry point i e the front door of a home A zone that may be temporarily violated either during the exit delay period or after violation of an entry exit zone This allows the user access to disarm the system A Follower zone will behave as per an Instant zone if violated prior to the violation of an entry exit zone When the system is armed violation of an instant zone will immediately cause an alarm condition to be registered Arming that allows for certain preprogrammed STAY zones to be violated while the system is armed Arming that allows the user to STAY ARM and leave the premises Zones which are bypassed automatically when the system is STAY ARMED A specific area of your premises guarded by sensors which detect violations of that area IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 5 1 Introduction to the IDS1200 The IDS1200 Control Panel is manufactured to the highest specifica tion and will provide many years of service if correctly installed and
20. ctory default is 1234 followed by the x key CODE NUMBER ARM TROUBLE Enter the USER CODE NUMBER you wish to change 1 32 followed by the x key CODE NUMBER 5 NEW CODE ARM TROUBLE Enter the new 4 digit USER CODE and press the x key CODE NUMBER 00 ARM TROUBLE Repeat steps 4 and 5 to enter or change other user codes Press to exit the User Code Menu MAIN MENU ARM TROUBLE Press to exit the Main Menu IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 01 01 99 READY ARM TROUBLE 11 2 Deleting User Codes LED Keypad Follow steps 1 5 of the procedure in 11 1 but only press the x key in step 6 That particular code will be deleted 11 2 1 Deleting User Codes LCD Keypad Follow steps 1 8 of the procedure in 11 1 1 but only press the x key in step 5 That particular code will be deleted 11 3 Maids Code The maids code User 15 in partition 1 and User 31 in partition 2 may be used to limit access to the premises The maids code will only disarm the system if the same code was used for arming If armed with a code other than a maids code the system will view an attempt to disarm with the maids code as an invalid entry Any valid user code will disarm the system if it has been armed with the maids code EXAMPLE If a maid is expected on a Monday arming the system on a Monday morning using the maids code will allow the maid to disarm the system On days
21. e lt menu keys to scroll to the stay zone you wish to cancel e g zone 3 ZONE 3 x TO DESELECI ARM TROUBLE 4 Press the x key to cancel the stay zone ZONE 3 FOR STAY ZONE ARM TROUBLE 5 Repeat steps 3 and 4 until required stay zones are cancelled 6 Press to exit the Stay Zone Mode 30 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 ZONE MENU ARM TROUBLE 7 Press to exit the Zone Menu MAIN MENU ARM TROUBLE 8 Press to exit the Main Menu 01 01 99 READY ARM TROUBLE 13 Buzz Zones Buzz zones are used when Stay arming When triggered buzz zones will cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alarm condition It is advisable to program Buzz zones if you are likely to accidentally trigger these zones or if you have pets This feature helps prevent unnecessary false alarms 4 ZONE NUMBER x 1 Ensure the READY indicator is illuminated 2 Hold down the 4 key until the keypad buzzer sounds 3 Press the NUMBER corresponding to the zone you wish to be a Buzz zone followed by the x key IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 31 4 The relevant Buzz zone will be shown by the illuminated zone indicator Stay zones will be shown by flashing indicators S
22. ed 01 01 99 STAY ARMED ARM TROUBLE kat 8 Any STAY zones shown by a steadily illuminated indicator will be automatically bypassed 9 Ensure that you enter only those zones that are bypassed IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 13 5 4 Quick Stay Arming 5 Hold down the key until the keypad buzzer sounds It is possible to STAY arm by holding down the 5 key until the keypad beeps There is no exit delay 5 5 Stay Arm and Go 6 Hold down the key until the keypad buzzer sounds This is a quick function which allows the user to STAY arm and leave the premises 1 Hold down the 6 key until the keypad buzzer sounds The ARMED LED will now flash for the duration of the exit delay 01701799 DELAY TIME ARM TROUBLE a 2 Atthe end of the exit delay the ARMED indicator will illuminate and the AWAY indicator will remain extinguished Any stay zones will be bypassed O17 01 99 STAY ARMED ARM TROUBLE 3 Be sure to leave only via the follower and entry exit zones 5 6 Arming a Partition from a Master Keypad Hold down MODE PARTITION NUMBER x USER CODE 1 Hold down the MODE key on a master keypad until the keypad buzzer sounds 14 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 PARTITION ARM TROUBLE 2 Enter the PARTITION NUMBER you wish to arm followed by the x key 3 Proceed as if the keypad was assigned to this p
23. ee Section 12 A Stay zone cannot be selected as a Buzz zone the Stay status must be cleared first 5 Repeat steps 1 3 until all the required Buzz zones are programmed 6 Press the key to exit the buzz programming mode 13 1 1 To Program Buzz Zones LCD Keypad 1 Hold down the 4 key until the keypad buzzer sounds BUZZ MODE ARM TROUBLE 2 Press the MODE menu gt key ZONE 1 FOR BUZZ ZONE ARM TROUBLE 3 Use the MODE menu gt and Fire lt menu keys to scroll to the zone you wish to be a buzz zone e g zone 3 ZONE 3 FOR BUZZ ZONE ARM TROUBLE 4 Press the x key to make the zone a buzz zone ZONE 3 TO DESELEGT ARM TROUBLE 5 Repeat steps 3 and 4 until buzz zones are selected 6 Press to exit the Buzz Zone Mode 32 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 ZONE MENU ARM TROUBLE 7 Press to exit the Zone Menu MAIN MENU ARM TROUBLE 8 Press to exit the Main Menu 01 01 99 READY ARM TROUBLE 13 2 To Cancel Buzz Zones 1 Repeat the above procedure and ensure that the zone indicator is extinguished When in Buzz zone programming mode use of a ZONE NUMBER the followed by key will toggle the status of the zone 13 2 1 To Cancel Buzz Zones LCD Keypad 1 Hold down the 4 key until the keypad buzzer sounds BUZZ MODE ARM TROUBLE IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 33
24. eriod Ensure that your installer has enabled this function if it is required Press this key only in an emergency situation that requires response by emergency personnel oe 4 P 4 22 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 8 3 Medical Alarm M Hold down the key until the keypad buzzer sounds If the M key is pressed until the keypad beeps approximately 1 second a MEDICAL ALARM condition will be activated 8 4 Duress Code DURESS CODE e This is a special 4 digit user code which should only used in the unique situation where an intruder forces one to disarm the system under duress When the DURESS CODE is entered the control panel disarms normally however a DURESS REPORTING CODE is trans mitted to the monitoring company to inform them that you have been forced to disarm the control panel by an intruder Itis advisable to choose a code that can be easily remembered by all family or staff members 9 0 Emergency Evacuation Plan An emergency evacuation plan should be established in case of a fire Draw up a floor plan of your premises showing windows doors stairs and rooftops that can be used for escape Indicate a suitable escape route for each room Always keep these routes free of obstruction Establish a meeting place outdoors for a headcount of the building s occupants Practice escape procedures IDS1200 USER MANUAL
25. ey 2 The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the 40 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 nominated zone is violated the siren will NOT sound and no alarm condition will be reported See page 35 for instructions on programming chime zones 15 4 2 Stay Zones Shortcut key 3 Stay zones are those zones which are bypassed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as bedrooms or other areas which require access must be bypassed Stay zones need only be programmed once Each time the system is armed in the stay mode the pre selected stay zones will be bypassed automatically See page 27 for instructions on how to program stay zones 15 4 3 Buzz Zones Shortcut key 4 Buzz zones are used when stay arming When triggered buzz zones will cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alarm condition It is advisable to program Buzz zones if you are likely to accidentally trigger these zones or if you have pets This feature helps prevent unnecessary false alarms See page 31 for instructions on how to program buzz zones 15 4 4 Bypass Zones Shortcut key 9 The term BYPASS is used to describe a zone that has been deactiva
26. her partition User Code 2 can only change partition 1 user codes in partition 1 User Code 17 can only change partition 2 user codes in partition 2 11 1 Entering New Changing Existing User Codes x MASTER USER CODE CODE NUMBER NEW CODE x NOTE User Codes can only be changed if the code is valid in the current partition 1 Hold down the x key until the keypad buzzer sounds 2 The ARMED and READY indicators will flash alternately indicating that the system is in the mode which allows programming of user codes 3 Enter the MASTER USER CODE the factory default is 1234 followed by the x key 4 The ARMED and READY indicators will begin to flash simultaneously indicating that the correct master code was entered If an invalid code was entered the keypad buzzer will beep three times 5 Enter the USER CODE NUMBER you wish to change 1 32 followed by the x key 6 Enter the new 4 digit USER CODE and press the x key Repeat steps 5 6 to enter or change other user codes 8 Once all the codes are programmed press the key to exit 11 1 1 Entering New Changing Existing User Codes LCD Keypad 1 Hold down the x key until the keypad buzzer sounds N MAIN MENU ARM TROUBLE IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 25 ES 26 Press 3 to enter the User Code Menu ENTER MASTER CODE ARM TROUBLE Enter the MASTER USER CODE the fa
27. maintained The unit is designed for simple operation yet provides the maximum protection for you your family or business For trouble free operation please follow the instructions contained in this User Manual Your security system consists of a control panel one or more key pads and various sensors and detectors An enclosure will contain the control panel which includes the system electronics fuses and stand by battery There is normally no reason for anyone other than the installer or service professional to have access to the control panel Read the entire manual carefully and keep it in an accessible place Your security system should be installed and serviced by a qualified security professional who should instruct you regarding the level of protection provided and the operation of the system Should you have any questions regarding the operation of the system contact your security company representative Your system should be tested on a regular basis Before testing the system please notify your security company of your intention to do so NEVER disconnect the mains power as the back up battery will eventually discharge thereby causing the control panel to shutdown A security system cannot prevent emergencies It is only intended to alert you and if included your central station of an emergency situation Smoke and heat detectors may not detect all fire situations 6 IDS1200 USER MANUAL NO 700
28. ones erre 37 15 LCD Keypad Menu Navigation ssnnnnrvevrnnnnnnnnnnnnnnrvnnnnnnnnnnnnnnnr 38 15 1 Main KO EE 38 52 View Menu seesinane irn dic ao Sadia nad din cn nes sola nadas snes semi 40 PN 40 15 4 Program Zones Zone Menu cccccsseseeeeeeceesseeeeesseeeeeeeeeseaees 40 15 5 Assign User Codes rarnnnnnnnrnnnnrnrnnnnnnnnnrssrnnrrnnnnnnnnnnsennennnnnnnnenn 42 15 6 Set Date and Time 2 cccccccccccsseseeeeecceeeccccoseeesceteceesscenceuseeess 42 BO SOVA eege 42 15 8 Stay Arm and AO EE 42 15 9 Reset Fire Sensor rrrnnnnnnnnnnnnnvrrrrnnnnnnnnnsvnnnnnnnnnnnnnnnsssennnnnnnnnnnn 42 15 10 Answer PIE eee 42 16 Trouble Shooting nd 43 16 1 Trouble Conditions ccccccccceesseeceeeeeseeeeceeeceeeeeeceeeeeeeeeeeeeeeaeas 43 16 2 Problems When Arming the System rrrnnnnnnrrrrrrvvvrrrrrrrnnnnnnnn 43 16 3 Problems when disarming the System rrrrrnnnnnnrrrnvrnnnnnnnrreennnn 44 VIT NE 44 4 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 Alarm Memory Arm Bypass Disarm Entry Exit Zone Follower Zone Instant Zone Stay Arm Stay Arm and Go Stay Zone Zone This is the history of the most recent violations that occurred the last time the system was armed To set the system into the ARMED mode In this mode violating a zone will activate an alarm condition If the system is programmed accordingly will cause a reporting code to be sent to the monitoring
29. ounds BYPASS MODE ARM TROUBLE 2 Press the MODE menu gt key ZONE 1 TO BYPASS ARM TROUBLE 3 Use the MODE menu gt and FIRE lt menu keys to scroll to the zone you wish to un bypass e g zone 3 ZONE 3 x TO DESELEGT ARM TROUBLE 4 Press x to un bypass the zone ZONE 3 TO BYPASS ARM TROUBLE 5 Repeat steps 3 and 4 to un bypass any other zones 6 Press to exit the bypass mode ZONE MENU ARM TROUBLE 7 Press to exit the zone menu IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 19 MAIN MENU ARM TROUBLE 8 Press to exit the main menu 01 01 99 READY ARM TROUBLE 7 Disarming the System 7 1 Disarming with a User Code USER CODE To disarm the system enter a valid USER CODE before the expiry of the entry delay Although not essential it is recommended that the key be pressed before entering a user code as this clears any unintended key entries Enter the premises through a designated entry exit door Enter ing via any other route will cause an alarm As soon as the entry exit zone is violated i e the door has been opened the entry delay begins The keypad buzzer will sound for the duration of the entry period to indicate that a valid user code is required If the ARMED indicator remains illuminated an error was made while entering the user code press the key and re enter the
30. s feature is enabled esch Press the remote button or twist and release the key switch 2 The system will disarm and the remote indicator if installed will extinguish 3 If programmed to do so the siren will sound briefly verify with your installer IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 21 8 Emergency Situations 8 1 Fire Alarm F Hold down the key until the keypad buzzer sounds Si Ze If the F key is pressed until the keypad beeps approximately 1 second a FIRE ALARM condition will be activated The FIRE ALARM CONDITION can also be triggered by a smoke detector connected to an appropriately programmed zone The siren will sound and the FIRE REPORTING CODE will be transmitted to the monitoring company To silence the siren enter a 4 digit USER CODE 8 2 Panic Alarm P Hold down the key until the keypad buzzer sounds we we oe we f the P key is pressed until the keypad beeps approximately 1 second a PANIC ALARM condition will be activated A PANIC ALARM can also be activated by any FIXED PANIC or REMOTE PANIC buttons which may have been installed H audible panic option has been selected the siren will sound A PANIC REPORTING CODE will be transmitted to the monitoring company To silence the siren enter a valid 4 digit USER CODE If the siren is not cancelled it will stop automatically after the programmed SIREN TIME OUT p
31. ted i e violation of a bypassed zone will not cause an alarm It is used when access is needed to part of the protected area while the system is armed Zones cannot be bypassed once the system is armed and bypassed zones are automatically cancelled each time the system is disarmed and must be re bypassed before the next arming See page 16 for instructions on how to bypass zones 15 4 5 Zone Names This option is used for description purposes i e instead of showing a zone 3 violation zone 3 would be repaced by the description programmed here eg kitchen IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 41 15 5 Assign User Codes The IDS1200 has 32 programmable user codes See page 24 for instructions on programming deleting and changing user codes 15 6 Set Date and Time This menu option allows the user to set the time and date on the panel 15 7 Stay Arm Shortcut key 5 Stay arming allows the user to arm the perimeter zones while disabling the interior zones so that it is possible to remain on the premises 15 8 Stay Arm amp Go Shortcut key 6 This function allows the user to STAY arm and leave the premises 15 9 Reset Fire Sensor Shortcut key If there has been a fire violation the fire sensor stays without power until it has been reset Entering this menu option resets the sensor 15 10 Answer Phone Shortcut key 8 This function would be used when the monitoring comp
32. those of the LED keypad For easy distinction of instructions the instructions for the LCD keypad are shaded in grey NOTE There is a section at the end of the manual dedicated to explaining the navigation of the LCD keypad menu 3 Operation of the LED Keypad To ensure correct operation of your security system it is essential to familiarize yourself with the use of the keypad The keypad has a buzzer command entry keys and zone and system status L E D s The keypad is used to send commands to the system and to display the current system status The keypad s will be mounted in a convenient location within 8 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 Ze the protected premises generally close to the entry exit zones A sensor which has registered an alarm condition will be indicated on the keypad by the corresponding zone light flashing The keypad buzzer will sound under the following conditions oe oe oe oe oe When any key is pressed during the entry of codes Three times if one or more of the zones are violated when attempting to arm the system To indicate a trouble condition During the entry exit delay Will sound for 2 seconds when a chime zone Is violated 4 System Information 4 1 Programmed Functions Check with your installer which of the following functions have been enabled LUUUUUUUUUUUUL Partitionate up to 2 partitions
33. zones as per step 3 5 Press the key to exit the chime programming mode 14 1 1 To Program the Chime Zones LCD Keypad 1 Hold down the 2 key until the keypad buzzer sounds CHIME MODE ARM TROUBLE 2 Press the MODE menu gt key ZONE 1 FOR CHIME ZONE ARM TROUBLE IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 35 3 Use the MODE menu gt and Fire lt menu keys to scroll to the zone you wish to be a chime zone e g zone 3 ZONE 3 FOR CHIME ZONE ARM TROUBLE 4 Press the x key to make the zone a chime zone ZONE 3 x TO DESELEGT ARM TROUBLE EN Repeat steps 3 and 4 until chime zones are selected 6 Press to exit the Chime Zone Mode ZONE MENU ARM TROUBLE 7 Press to exit the Zone Menu MAIN MENU ARM TROUBLE 8 Press to exit the Main Menu 01 01 99 READY ARM TROUBLE 36 IDS1200 USER MANUAL NO 700 171 01B ISSUED AUG 2002 VER 1 18 14 2 To Cancel the Chime Zones 2 ZONE NUMBER x 1 Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash to show that the panel is on the chime programming mode 3 To cancel any chime zones press the key corresponding to that zone followed by the x key 4 Press the key to exit the chime programming mode 14 2 1 To Cancel the Chime Zones LCD Keypad 1 Hold down the 2 key until the keypad buzzer sounds CHIME MODE ARM T