Home

USER MANUAL ELECTRIC FAN WITH HUMIDIFIER Model: ORION

image

Contents

1. ORION USER MANUAL ELECTRIC FAN WITH HUMIDIFIER Model ORION OF1601S Thank you for your purchase Please read this manual thoroughly before plugging it in Introduction This product has both fan and humidifier functions which can be used together or separately The humidifier is especially useful on very hot days when the extra mist in the air helps not only to cool you down but also to increase the humidity in the dry heat How does it work This Mist Fan uses ultrasonic vibration to atomise water into 1 5 micron particles which can then be blown through the room with the fan Why is it useful Not only does this fan help to cool you down with air containing micro water droplets it also helps to avoid dry skin and eyes which are common in dry heat A relative humidity of 45 65 is recommended for comfortable living and this fan can help maintain that balance in the hot summer months Parts Front mist plate Front Guard Blade cap Blade Guard Mounting Nut Rear Guard Motor Fan Body Base 10 Castor wheels 11 Base Nut 12 Fixer 13 Plastic Tube 14 Tube Button 2 ee ee Technical Data Rated Voltage 230V Rated Frequency 50Hz General Power 120W Max Mist Capacity 200ml h Fan Head Size 400mm th Plastic Tube Water Tank Capacity 1500m ad Display Installation 1 First base is installed in place of the main stable 2 The head fixed in the main part of the bearing hole 3 Insta
2. d physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Subject to change without notice vm Els
3. he elderly should not be in the direct airflow from the fan for long periods of time Cleaning and Maintenance Make sure power is disconnected before any cleaning or maintenance is performed Gl TS Ja H It is recommended that you clean the water tank every 2 3 weeks of use and clean the flume every week ri 1 Plastic Tube Flume Mist Patch Water Overflow Hole o i a ae Ai Pull out the water tank before cleaning it pull the plastic tube out of the mist cask properly then take out the mist cask and water tank Water Tank Use a dry cloth to clean the mist cask If there are stubborn stains on the mist cask use a cloth lightly dampened with mild detergent Mist Cask If the mist feature will not be used for a long time empty the water tank and leave it to dry before recapping It Troubleshooting Fault Phenomenon a Water could be contaminated with other substances a Clean out the water tank and replace with clean Mist projector works water or chemicals normally but without mist b Pour out the water and check for cracks b Water tank could be cracked spray c Refill the water tank A full tank of water will last c Water tank could be empty approximately 8 hours a Free the bobber and allowit to float freely a Bobber doesn t float 2 Mist projector doesn t work b Refill the water tank A full tank of water will last b Water tank could be em
4. lled guard and blade and net fixed firmly lock the lookout Network Filling the water tank Place the fan on a flat stable floor then add water for the humidifying function as follows 1 Open the water tank 2 Lift out the water tank 3 Take out the water tank cover 6 Screw tank cover tightly and tank so the outlet cap is add water put it into the fan then close facing upwards panel Operation mosquito negative ion repeller generator Wind speed Wind species Power Timing Humidity Insert plug to the electrical outlet and the indicator light turns on Press ON SPEED button to choose the wind for low Med High speed that matches the light on the control panel Press MODE to choose the wind type from one of the following Normal Wind flow based on Low Med High speed Breeze Imitates the flow of natural wind based on strong and soft wind Sleep The fan runs for half an hour on strong then soft natural wind mode then changes to soft natural wind for the next half hour and then the fan turns off automatically 1 Setting H Operation pattern H Stop H Stop H 2 Setting M Operation pattern M stop M Stop M 3 Setting L Operation pattern L gt Stop L off L Press SWING to start oscillation press again to fix the airflow direction Press HUMIDITY to start the humidifying function mist comes out of the front plate if there is wa
5. pty approximately 8 hours a Power cord is unplugged and electric power is 3 No indicator light no wind no a Plug the power cord and turn on the electric mist 4 Peculiar smell from the mist 5 The fan doesn t work as normal power off a When new there might be residue in the water tank mist plate b The water in the water tank many be contaminated a The plug and supply cord are damaged b The blades are bend c Don t safety device power a The smell should disappear after further use b Clean out the water tank and refill with fresh water a Find service agent or a suitable qualified person to change or service b Don t play the blades Use soft damp cloth then wipe with dry cloth c Installed correctly in accordance with the manual Can not be installed until there is no electricity Mist Patch ond Sp gt Overflow water Gap Figure of cleaning mist patch WARNING Unplug from electrical supply source before cleaning After servicing any safety device including grilles and blades must be reinstalled or remounted as previously installed Use soft damp cloth then wipe with dry cloth Do not use harmful cleaners Do not bend the blades If the plug and supply cord are damaged it must be replaced by the manufacturer its service agent or a suitable qualified person in order to avoid a hazard This appliance ts not intended for use by persons including children with reduce
6. ter in the tank The MIST function can be used on its own or along with the fan function to blow the mist into the room Press TIMER button to make the fan run for the length of the timer There are 4 indicator lights for automatic timing To set a time of 7 5 hours you need to press 15 times and all the 4 indicator lights light up The Remote Control must be pointed towards the Remote Sensor on the main unit for best results If the remote control doesnt operate as expected replace the batteries 2 pcs AAA battery Press NEGATIVE ION GENERATOR to start the negative ion function Caution Do not touch pull out put back the water tank when the unit is plugged into a power source Make sure It is physically disconnected from the mains before doing anything with the water tank When the water level is too low the safety switch will cut out operation of the mist function Unplug the unit and refill the water tank for further operation Do not let dust or other particles collect on the mist plate if the mist outlets are blocked the mist function could malfunction Before cleaning the unit make sure it is completely disconnected from the power source Make sure your hands are not wet when unplugging the unit Do not use very hot water in the water tank use water less than 40 degrees Celsius Use only water in the water tank Do not add chemicals or oils or any other additive Infants the disabled and t

Download Pdf Manuals

image

Related Search

Related Contents

Wasser-Wärmepumpe TTF 20-66 (PDF 5 MB)  Stellaris LM3S2965 Evaluation Board User`s Manual (Rev. A)  Verbatim PAR38 3000K 1250lm  SoftBank 008Z 取扱説明書  取扱説明書 操作・設定編 - psn  ROSCAMATIC 2 COMBI  取扱説明書 - RS Taichi  A4 - Rush Flat Consulting  CLAIMS MANUAL    

Copyright © All rights reserved.
Failed to retrieve file