SL-3GHD128128 User manual

image

Contents

1. OpenTCP includes software developed by Viola systems http www violasystems com nevion com 20 SL 3GHD128128 Rev D Appendix A Materials declaration and recycling information A 1 Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements ERER Fi R ACMA SRK ZR ER Part Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr VI PBB PBDE SL 3GHD128128 O O O O O O Multicon O O O O O O SL PWR 300 O O O O O O O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 This is indicated by the product marking A 2 Recycling information Nevion provides assistance to customers and recyclers through our web site http www nevion com Please contact Nevion s Customer Support for assistance with recycling if this site does not
2. 3Gbps Reclocking on standard 3G HD SD SDI signals Reclockers may be turned off for support of E4 STM 1e Ethernet and RS 232 control interfaces Software based Configurator for easy system set up Ultra Slim frame depth Low Power consumption lt 150W high reliability design Redundant power supply system with front indicators Interoperability with existing VikinX routers Possible to split the router into independent partitions on separate levels Multicon is embedded in the router All control features that come with Multicon VX SLC are available as default Future proof and flexible product range VikinX Sublime provides many of the powerful control features that drove the VikinX Modular range to success VikinX Sublime is ideal for general purpose facilities on air routing mobile outside broadcast applications and sophisticated A V applications VikinX Sublime SL 3GHD128128 provides most important 3rd party control interfaces allowing the control of our routers through 3rd party management software On top of that the embedded Multicon system controller allows control of the most common 3rd party routers This enables you to utilize existing routers and management systems from other nevion com 4 SL 3GHD128128 Rev D manufacturers and still draw the advantages of implementing VikinX Sublime in your routing application 1 1 Product variants There are a number of variants
3. 3 GHz 800mVp p 10 20 80 SD limit 0 4ns 1 5ns lt 0 5ns rise fall variation HD limit lt 270ps lt 100ps rise fall variation 3G limit lt 135ps lt 50ps rise fall variation lt 10 Non inverting electrical with respect to inputs SD lt 0 2 Ul 3G HD lt 1 Ul SD lt 0 2 Ul 3G HD lt 0 2 Ul 1 75 ohm BNC female loop thru gt 40dB 100 kHz 5 MHz gt 35dB 5 10 MHz NTSC or PAL Black amp Burst or HD Tri Level according to SMPTE 274M SMPTE 276M Nominal 1 0Vp p Field 1 HD Tri Level 1280x720 within clock intervals 148 5 MHz 455 780 line 7 HD Tri Level 1920x1080 within clock intervals 148 5 MHz 625 1070 line 7 nevion com 8 SL 3GHD128128 Rev D 2 5 Rear view 99 09 00 VU 09 oD LE CF 1 22 ro PE OO Dp 90 00 Of DD D Of 20 20 Oe 09 99 99 5 amp OR 3 de oe ee Qo 6 SO OKJ ODO oa 2 ej amp oe ov god oe amp 0 00 SLS CSE Qi SIM 6 09 Qo 32 Oe oe oo G5 o gt l ae ee I D 96 OD i G G6 v YS He Ye gt gt Oe Qe ee eee e
4. show the information you require Where it is not possible to return the product to Nevion or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labeled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory devices nevion com 21
5. 3GHD128128 6 Connecting signal cables to the router The SL 3GHD128128 router offers standard 75Ohms BNC connectors for video in and See also Chapters 2 4 2 5 and 0 for more details The figure below shows the I O ing outputs number QQ ere 2 OO JO a a OO nevion com 17 SL 3GHD128128 Rev D General environmental requirements for Nevion equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 45 C Operating relative humidity range lt 95 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 55 C Relative humidity range lt 95 non condensing nevion com 18 SL 3GHD128128 Rev D Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Nevion which are available on the company web site www nevion com nevion com 19 SL 3GHD128128 Rev D Important notes regarding Software in the VikinX Sublime router family range This product utilizes software components that are licensed with open source licenses The source code for these components and our modifications are available from http labs nevion com open source
6. L UPG 320UT Upgrade to add 32x Outputs to your partly configured SL 3GHD128128 router SL UPG 32IN OUT Upgrade to add 32x Inputs and Outputs to your partly configured SL 3GHD128128 router Power Supply Unit SL PWR 300 300W AC Power Supply Unit for Sublime 128 range 48VDC output nevion com 6 SL 3GHD128128 2 Specifications 2 1 Mechanics Dimensions Router weight Max Power consumption Safety Emission standards 2 2 Power supply SL PWR 300 AC Supply voltage range AC Mains connector DC output DC connector Alarms Alarms connector Safety standards 2 3 Control Standard Features Serial port Connector s Ethernet port Connector Reclocker option Input Equalizer option Synchronization handled by Multicon Connector s Other features Rev D HxWxD 355x483x50mm 19 8RU 7 75 kg including 1x PSU module 1 15 kg 48V 2 8A 135W Compliant with CE EN55103 1 and 2 300 W Power supply Unit 90 130VAC 180 254VAC switchable 50 60Hz 300W IEC 320 48V max 6 25A Maximum 300 W DSUB 2V2P Power failure alarm on LED in front and GPI output from MULTICON RJ45 Compliant with CE EN60950 UL 1950 CSA22 2 RS 232 for protocol conversion to VikinX compact control protocol or to third party protocols DEQ D sub 9 pin female 10 100BaseT Ethernet bus for external router control RJ45 Bypass of reclocking from system contro
7. The following service connectors can be found on the rear of the SL 3GHD1281 28 router Power A 48 VDC 48 VDC power connector Power B 48 VDC 48 VDC power connector if redundant supply is installed ks Serial 1 and 2 RS 232 or RS 422 ports for external control protocols Ethernet 10 100Base T Ethernet bus for external router control GPI Power fail alarm relay contact Contact closes if any of the connected power supplies fail or the internal power level is below limit LED status on the power supplies indicate which one has failed See Chapters 2 2 and 3 3 for further description Sync Loop Synchronization signal in out Black amp Burst composite tri level sync reference input with passive loop through for vertical interval switching Configuration Configurations switch See Chapter 3 for further descriptions 2 5 1 Power Supply pinout The DSUB 2V2P power pinout for Sublime routers and Control Panels are as follows Pin Description Socket 48VDC Pin GND 1 Note that any VDC supplies with output voltage between 36VDC and 72 VDC with sufficient power may be applied to the router The router is supplied with inverse diodes This means that in a redundant power supply application the router will pull its entire load from the PSU with the highest output voltage nevion com 9 SL 3GHD128128 Rev D p There is a switch on the right hand side of the power supply
8. aatieininlts 15 5 Router COMMUNICALION ccccccccccccccececeeeeeceeeceeceeceeceeececeeeeeeeeeececeeeeeeeeeeeeeeeseess 16 6 Connecting signal cables to the router sssssseereeerr renerne nn 17 General environmental requirements for Nevion equipment se 18 Product Warranty sso ceed eed oheoc cet eh reaetdedesonat ota tesdateniaedaswrecdadeasaysateacnsdeteonendetuaonssiees 19 Important notes regarding Software in the VikinX Sublime router family range 20 Appendix A Materials declaration and recycling information seere 21 Axl Materials Geclarauontivcs cccctercerseulvs ets uvoes ccdewtoneelavmen sence tends O ERA AANE ERARE 21 A 2 Recycling information vesccceesetesccecacpeceta nc coceececueetacl toca et et EE aee taren tiecmetienacttaee 21 nevion com 3 SL 3GHD128128 Rev D 1 Product overview ROY A 7 f 7 Ki g 4 Nevion proudly presents Sublime SL 3GHD128128 With this router Nevion continues a stable and proven product line including the most complete signal format and size offering available With the ultra slim multi format and flexible product range Sublime fulfils the most demanding requirements from the professional broadcast market This User Manual presents the features installation and operation procedures of the SL 3GHD128128 router of the Sublime range The key features of SL 3GHD128128 are Multi rate support 3G HD SD SDI Supports DVB ASI Supported bitrates 143Mbps
9. ates that the LED keeps the color it has the moment the alarm sequence begins green yellow or no light Description LED state Alarm Comment Continuous GGGGG GGGGG GGGGG No alarm green light GGGGG Status is OK Continuous YYYYY YYYYY YYYYY YYYYY Unable to This alarm will be yellow light connect to overwritten by other controller over alarms Ethernet Long red RRRRR NNNNN RRRRR NNNNN Power is too blinks low One short RXXXX XXXXX XXXXX XXXXX Power A Only active if power red blink failed alarm dip is set Two short XXXXX XXXXX RXRXX XXXXX Power B Only active if power red blinks failed alarm dip is set Red with one YRRRR RRRRR RRRRR RRRRR No valid short yellow product key blink 4 3 Ethernet states The LEDs that are located at the Ethernet bus will after the Start up sequence indicate the Ethernet states On Off Blinking Green Valid link No link Yellow No data Data is transmitted or received nevion com 15 SL 3GHD128128 5 Router communication Rev D You gain access to router for communication purposes by connecting either the router s serial port to your computer and or by using an Ethernet connection Site 3 z Site 2 Internet i Please refer to the manual for Multicon VX SLC for a detailed description of the applicable communication interfaces for your modular router nevion com 16 Rev D SL
10. defined partitions is selected according to the following pattern SW5 SW6 Router partitions OFF OFF 1 partition OFF ON 2 partitions ON OFF 3 partitions ON ON 4 partitions Default mode is 1 partition nevion com 11 SL 3GHD128128 Rev D Based on the configuration above the I O is connected to the router according to the following scheme 1 partition I O is connected according to information on the rear of the router 2 partitions 3 partitions Partition 1 Input Partition 1 Output 1 1 1 1 2 2 2 2 3 3 3 3 64 64 64 64 Partition 2 Input Partition 2 Output 1 65 1 65 2 66 2 66 3 67 3 67 64 128 64 128 Partition 1 Input Partition Output 1 1 1 1 2 2 2 2 3 3 3 3 42 42 42 42 Partition 2 Input Partition 2 Output 1 43 1 43 2 44 2 44 3 45 3 45 42 84 42 84 Partition 3 Input Partition3 Output 1 85 1 85 2 86 2 86 3 87 3 87 42 126 42 126 In Outputs 127 and 128 are not in use in this router setup 3 partitions nevion com 12 SL 3GHD128128 4 partitions Rev D Partition 1 Input Partition 1 Output 1 1 1 1 2 2 2 2 32 32 32 32 Partition 2 Input Partition 2 Output 1 33 1 33 2 34 2 34 32 64 32 64 Partition 3 Input Partition3 Out
11. for this product They all share the same hardware and are distinguished by FW keys Item Description SL 3GHD128128 128x128 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD96128 96x128 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD96128 128x96 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD64128 64x128 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD12864 128x64 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD32128 32x128 HD SDI Router Multi rate 270Mbps 2 970Gbps Sup
12. igurator v4 1 1 or a higher version number when configuring the SL 3GHD128128 and its variants 3 1 Power Supply setup Before proceeding with router configuration make sure the accompanying power supply unit is configured for the right AC supply voltage There is a switch on the rear side of the power supply module that selects mains voltage The mains voltage can be either 110VAC or 230VAC This switch must be set in the correct position depending on the mains voltage on the router s site Failing to select correct AC mains voltage properly may damage the Power Supply Unit 3 2 Router mode SL 3GHD128128 allows easy splitting of the router into a maximum of 4 pre defined partitions You may not control these pre defined partitions individually if you use the DIP switches to configure partitions Leave switches 5 6 in the default position and configure the number of individually controlled partitions you like using the Nevion Configurator that comes with the router Software configured partitions may be of any size You can choose among the following pre defined partitions Router partitions Partition sizes 1 partition 128x128 2 partitions 64x64 3 partitions 42x42 4 partitions 32x32 Switches 5 6 on the configuration switch set the number of pre defined partitions The Router Management System software must be configured according to the chosen setup The number of pre
13. ller Bypass of input equalization from system controller Analog Black amp Burst looped Both PAL and NTSC supported Tri Level Looped For HD signal formats only Distribution of synchronization signals between several routers BNC SNMP agent included with Multicon 2 4 Video specifications Supported formats Telecom Broadcast Supported standards SD SDI 270Mbps HD SDI 1 485Gbps 3G SDI 2 97Gbps DVB ASI Electrical signal inputs Connectors Impedance STM 1e and E4 143Mbps 2 97Gbps DVB ASI SMPTE 259M SMPTE 292M SMPTE 310M SMPTE 424M 2K 2048x1556 23 98 and 24 SMPTE 259M SMPTE 292 2008 SMPTE 424M EN50083 9 BNC IEC 61169 8 75 Ohm nevion com 7 SL 3GHD128128 Return loss Cable equalization Electrical signal outputs Connector Impedance Return loss Signal level Rise fall time Amplitude overshoot Signal polarity Signal transition Timing jitter Alignment jitter Reference inputs Number of inputs Connector Return loss Signal format Signal level Field selectivity Timing range Rev D gt 15dB 5 MHz 1 485 GHz gt 10dB 1 5 3 GHz Automatic up to 70m 2 97Gbps typical Belden 1694A Automatic up to 100m 1 485Gbps typical Belden 1694A Automatic up to 300m 270Mbps typical Belden 8281 BNC IEC 61169 8 75 Ohm gt 15dB 5 MHz 1 485 GHz gt 10dB 1 5
14. module that selects mains voltage The mains voltage can be either 110VAC or 230VAC This switch must be set in the correct position depending on the mains voltage on the router s site Failing to select correct AC mains voltage properly may damage the Power Supply Unit 2 5 2 Serial port pinout The DB9F connectors for the serial port s of the router have the following pin out Pin RS 232 mode RS 422 mode 1 Not in use Not in use 2 Tx Tx 3 Rx Rx 4 Not in use Not in use 5 GND GND 6 GND GND 7 RTS Tx 8 CTS Rx 9 Do Not Connect Do Not Connect Note that if the standard RS 232 cable specification DCE is followed a cable with Male Male or Female Female connectors at the cable ends is used for Rx Tx crossed connection and a cable with Male Female connectors at the cable ends is used for a straight through connection nevion com 10 SL 3GHD128128 Rev D 3 Configuration This chapter provides an overview of the configuration options that are available on the SL 3GHD1281 28 router Switches 1 4 on the configuration switch are not in use and must be kept in the OFF position factory default Some of the configuration options demand software configuration using the Nevion Configurator This tool is supplied with each router but can also be downloaded from our web site www nevion com support It is important that users apply Nevion Conf
15. nevicn SL 3GHD128128 VikinX Sublime 128x128 3G HD SD SDI Router User manual Rev D Nevion nevion com SL 3GHD128128 Rev D Nevion Support Nevion Europe Nevion USA P O Box 1020 1600 Emerson Avenue 3204 Sandefjord Norway Oxnard CA 93033 USA Support phone 1 47 33 48 99 97 Toll free North America 866 515 0811 Support phone 2 47 90 60 99 99 Outside North America 1 805 247 8560 E mail support nevion com See http www nevion com support for service hours for customer support globally Revision history Current revision of this document is the uppermost in the table below Rev Repl Date Sign Change description D 3 2013 07 18 JGS Update to new template no change in document 3 2 2011 10 13 NBS Corrected housing and gender spec on D sub 9 pin contacts Updated Chapter 2 5 Added SD SDI Cable EQ spec in Chapter 2 4 Added one LED status in Chapter 4 2 Added Declaration of Conformity 2 1 2010 05 21 NBS Added information about Nevion Configurator including version information Updated PSU information Added Chapter 3 1 about PSU configuration Added Chapter 1 1 about product variants 1 0 2010 02 26 NBS Corrected hyperlink to Multicon and other minor corrections 0 2010 02 03 NBS First release nevion com 2 SL 3GHD128128 Rev D Contents Revision history execscrtetssaks teeter ttcrencssateacpebttraaees ousancdte enn 2 1 Pr
16. oduct overview ssi li ii li ei ee i rrr EEEE EEEE 4 TT Product Vai BINS T 5 2 Specification Saan eian a n i a a hash kbh ESKE 7 2 Mechanism si re E EEE ge Mairead Sai A 7 2 2 POWEr SUPPLY ciroen a E AE E EEE ER E ER E AT see 7 2 3 COMM Ol EAEE E E E E E E ES EE EE aden 7 2 4 Video specifications 0 cece eee ee cece e eect eee eeeeeeeaaeaeee eee eeeaaaaaaaaeeeeeeeeeeaaaaaaaaeeseeeeeseeesaaaaes 7 ZO ROAR VISW sad nec i han met SS at nc re ENN marke ig Nee bea Nh ncaa al Ieee a Se athe Narada 9 2 5 POWER SUP PINOUT sirma Soe egestas dr aner tens acne eae bab byer ater wena a 9 2 5 2 S6rial port DIMOU raira pi n a hane Es Eee E Eo daaa Neden d E EAEE NY 10 g Gong ratlo mksa enaa aea tetas ena eA A a ia a a ia 11 Sil Powe Sup plys et a a a ede a a e eed thes 11 3 2 Router Mode miera aE re a EVE sera bee EE aE PEEVE AA ade EE 11 3 3 External power alarm sseeeeeeeeerrrrr nere 13 3 4 Power up Mode sa rar eien nen nnn a aE ah A een aeaa 14 3 5 Configuring switching time 2 cant eee eee as losses ee recese ede alecets Gu cscesmuseanievedatu asec teens 14 4 LED status indication ssssssssssssssssssssssssssssssesssssssssessssssesessssssesssssseeees 15 4V SLAP ck ets REESE Ea calc a a SEERE AAE de Meceaa vad seed sd demas Eee NE SES cuted 15 4 2 Alarm stateSi ns hos Gees cc aon Gece chan anes if rte mles alene den Sean cha aN EO oem eects ae 15 4 3 AEREI EEA nae EA E AA naxiedeulacvyle ancieaseantudene naxedeulaoiylencan
17. om 13 SL 3GHD128128 Rev D 3 4 Power up mode Switch 8 on the configuration switch defines the power up mode The sublime router provides two modes for powering up the system The power up options can be switched according to the following pattern SW 8 Power Up mode OFF Switches all outputs according to the buffered information in the routers processor system ON Switches all outputs to input 1 Default setting switches all outputs according to the buffered information in the routers processor system 3 5 Configuring switching time This configuration is done in the Nevion Configurator It is possible to configure switching time in the router The settings are made through the Nevion Configurator but a description of the options is given here The user can select between three options 1 Switch according to detected sync reference signal Default Switching time is determined by the synchronization signal that feeds the router This is useful when the video signal has the same format as the synchronization signal Supported formats are PAL NTSC 750 50p 750 60p 1125 50i and 1125 60i Switch according to signal format Select format Here it is possible to use one synchronization signal to switch a different video format A prerequisite is that the synchronization signal and the video signal have the same frame rate E g Use PAL as synchronization signal with a 750 50p video signal Supp
18. orted formats are PAL NTSC 750 50p 750 60p 1125 50i 1125 60i 1125 50p and 1125 60p We do not support 1125 50p or 1125 60p as synchronization signal This means that our 3G HD routers cannot use default setting Switch to handle mixed signal formats The router switches 12us after vertical sync on the synchronization signal This will occur in line 1 on all video formats This is useful when you have different video formats on the same router also with different frame rate This setting is not according to recommendations in SMPTE RP 168 2002 Embedded data may become damaged or lost nevion com 14 SL 3GHD128128 Rev D 4 LED status indication 4 1 Start up The LED located at the front of the router indicates the status of the router At start up the LED will alternate between red R and green G every 500ms for about two seconds After the start up sequence the LED will indicate the Alarm state of the router There are two LEDs located at the Ethernet bus At start up the boot loader is searching for update commands on the serial port for about two seconds During this sequence both Ethernet LEDs will be blinking After the start up sequence the LEDs will indicate the Ethernet state 4 2 Alarm states The LED can either be red R green G yellow Y or have no light N The LED state is here described with twenty letters each representing 100ms which totals to an alarm sequence of two seconds The X indic
19. ports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD12832 128x32 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD9696 96x96 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD6496 64x96 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD9664 96x64 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD3296 32x96 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded con
20. put 1 65 1 65 2 66 2 66 32 96 32 96 Partition 4 Input Partition 4 Output 1 97 1 97 2 98 2 98 32 128 32 128 3 3 External power alarm The external power alarm can be switched according to the following pattern SW 7 Power alarm OFF Disables External Power Alarm ON Enables External Power Alarm Default setting is External Power Alarm disabled The Power Alarm GPI output will generate a contact closure if the internal voltage is below a certain threshold regardless of the position of DIP 7 This DIP switch only determines if a faulty external power supply shall generate an alarm contact closure This means that enabling this power alarm should only be considered if you have connected both external power supplies for redundant supply Then a contact closure will be generated if any of the connected power supplies fail The associated power fail alarm relay contact on the rear side of the frame is described in Chapter 2 5 The relay contact is normally open and the contact closes according to the description in this chapter Pin Signal Name Mode 1 Not in use Input 2 Not in use Input 3 Not in use Input 4 Not in use Input 5 PSU Alarm Power alarm as Open Collector described above 6 Not in use 7 5V 5V pin 5V 8 GND OV Ground GND Br own Pair 4 VA Blue Green Pair 1 Pair 3 Or ange Dorr S nevion c
21. troller SL 3GHD9632 96x32 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 nevion com 5 SL 3GHD128128 Rev D Item Description Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD64 64x64 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD3264 32x64 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD6432 64x32 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL 3GHD32 32x32 HD SDI Router Multi rate 270Mbps 2 970Gbps Supports 3G SDI HD SDI SD SDI DVB ASI Upgradeable to 128x128 Ethernet RS 232 control router partitioning on separate levels 19 8RU depth 5cm Multicon VX SLC embedded controller SL UPG 32IN Upgrade to add 32x Inputs to your partly configured SL 3GHD128128 router S