Home

Installation Manual

image

Contents

1. info stpumps co uk www stuart turner co uk Pt No 19653 Issue No 2415 2 03
2. on the electrical supply ensure power supply is isolated 4 14 Isolate all appliances in the water from the electrical supply before putting your hands in the water 4 15 The power supply cord of this pump cannot be replaced If the cord is damaged the pump should be disposed of see Section 8 11 4 16 Ifthe pump is used to empty a swimming pool the pump must not be used when people are in the water Earthing This appliance must be earthed via the supply cord Connections The motor is provided with a factory fitted supply cord and plug This must be connected to the mains supply via a 13 Amp double pole switched socket outlet in compliance with BS 1363 2 The socket outlet should be mounted in an easily accessible position and should be labelled if confusion is possible to allow easy identification of the pump isolating switch Wiring Of Connection Unit The moulded plug fitted to this appliance is not waterproof keep dry If the plug supplied is not suitable for your socket outlet it should be cut off and destroyed A plug with bared flexible cords is hazardous if engaged in a live socket outlet The wires in the mains lead supply cord are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your connection unit proceed as follows The wire which
3. COMMENCING PUMP INSTALLATION Water temperature The water entering the pump must be controlled as follows 1 11 The maximum allowable water temperature is 35 C 1 12 The minimum allowable water temperature is 4 C Pipework general 1 13 All models are supplied with a hose connector See pump connection section for details which can be screwed directly into the pump discharge connection 1 14 The hose connector is suitable for a 25 mm hose size For best flow use the largest bore pipe possible minimising 90 bends Small pipe sizes will reduce the pump performance Electrical installation regulations 1 15 The electrical installation must be carried out in accordance with the current national electrical regulations 1 16 The electrical installation must be installed by a qualified person Cont 2 LOCATION GENERAL A Fig 2 2 11 2 12 2 13 2 14 2 15 Inlet filter area Access For emergencies and maintenance the pump must be easily accessible Do not run against a closed valve for periods longer than 5 minutes The water in and around the pump must not be allowed to freeze This will result in pump damage Do not under any circumstances use the supply cord fitted as a means to carry or lower the pump into position on installation Attach a rope sling to handle Never run pump whilst sucking air only as the motor will overheat To prevent this happening always install pump in the vertical
4. STUART TURNER ENGINEERED TO EXCEL stuart Installation Operation amp Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products Diver 35 Diver 45 Pt No 46585 Pt No 46586 50 Hz PRODUCT DESCRIPTION Electric motor driven submersible pump with float switch control APPLICATION The Diver pump range is designed for re circulation drainage and transfer of clean fresh water in outdoor or indoor applications All models within the range incorporate an adjustable float switch assembly which provides automatic pump control These models are suitable for clean water only e This pump set must not be used for any other application without the written consent of Stuart Turner Limited e Do not connect this pump to the mains water supply e The use of this product requires experience with and knowledge of the product Persons with reduced physical sensory or mental capabilities must not use this product unless they are under supervision or have been instructed in the use of the product by a person responsible for their safety e Children must not use or play with this product Please read installation details carefully as they are intended to ensure this product provides long trouble free ser
5. dule Boostamatic only G1 male Motor Electrical Physical Stuart Turner reserve the right to amend the specification in line with its policy of continuous development of its products Maximum permissible water temperature 35 C 7 11 Noise The equivalent continuous A weighted sound pressure level at a distance of 1 metre from the pump does not exceed 70 dB A Cont 12 8 TROUBLE SHOOTING GUIDE Symptoms Probable Cause Recommended Action Pump stops running Thermal overload Disconnect the power supply to the protection has pump tripped Allow to cool for 30 mins Check to ensure the pump is connected to the correct voltage supply Check to ensure the impeller is not jammed and can rotate freely Check to ensure water to be pumped does not exceed recommended temperature ensure pump has not run dry and is fully submerged Check probable causes and remedy allow to cool reinstall and connect cable Pump will not start Pump not connected Check the cable is connected correctly to the electricity and power supply is switched on supply Check fuse Impeller Jammed Clean away debris from the impeller Float switch not Check the float switch by hand do not working attempt to dismantle float switch for further advice contact Stuart Turner Pump runs but no Low water level Ensure the pump is fully submersed water is supplied below the water level Ensure that the pump is not able to suck a
6. hart 2 23 Wherever the pump is installed it must have sufficient dimensions for the float switch to operate freely Fig 7 retaining a minimum water depth as previously stated The pump is continuously rated when fully submerged but should only be run for short periods 10 mins when the water drops to the minimum level The number of starts should not exceed 30 per hour Note It is not possible to empty the sump completely a minimum depth must remain Figs 5 amp 6 470 Ny oN START STOP Vv 450 A i Eg O ge XK K ASS pi KS S j um m m my Fig 5 Min Float Fig 6 Max Float Switch Movement Switch Movement START STOP CABLE START STOP CABLE PUMP TYPE MIN ADJ MIN ADJ MIN ADJ MAX ADJ MAX ADJ MAX ADJ Ali models 3 PUMP CONNECTIONS 3 11 Diver pumps have a 1 BSP female connection and are supplied with a 25 mm hose connector Pump Pump Type Outlet Hose Bore mm Hose Connector Cont 4 ELECTRICAL INSTALLATION 4 11 Regulations The electrical installation must be carried out in 4 17 4 18 4 19 4 20 4 21 accordance with the current local regulations by a qualified person 4 12 Safety In the interests of electrical safety a 30 mA residual current device R C D not supplied should be installed in the supply circuit This may be part of a consumer unit or a separate unit 4 13 Before starting work
7. ir in low water level Discharge pipe Remove pipe and ensure the discharge clogged is clear of any debris Suction filter Check inlet pre filters if fitted are free blocked from blockages 8 11 Environment Protection Your appliance contains valuable materials which can be recovered or recycled At the end of the products useful life please leave it at an appropriate local civic waste collection point Cont 13 9 THE GUARANTEE 1 YEAR Congratulations on purchasing a Stuart Turner pump We are confident this pump will provide many years of trouble free service as all our products are manufactured to the very highest standard All Stuart Pumps are guaranteed to be free from defects in materials or workmanship for 1 year from the date of purchase Within the guarantee period we will repair free of charge any defects in the pump resulting from faults in material or workmanship repairing or exchanging the whole unit as we may reasonably decide Not covered by this guarantee Damage arising from incorrect installation improper use unauthorised repair normal wear and tear and defects which have a negligible effect on the value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date of claim Such as proof of purchase or the pump serial number This guarantee is in addition to your statutory rights as a consumer If y
8. is coloured green and yellow must be connected to the terminal in the connection unit which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red Fuse All models should use 13 Amp fuse Float switch cord replacement The float switch cord cannot be replaced If the cord is damaged the pump should be disposed of see Section 8 11 Cont 4 22 Supply cord extension pump The pumps are fitted with a supply cord suitable for outdoor and underwater use The cord specification is as follows Pump Type Cord Type Cord Length m If an extension cord is necessary a cord of the proper type and rating must be used In general for 230 volt pumps on distances up to 40 metres inclusive of original cord length the same specification cord as fitted to the pump can be used For distances above 40 metres a larger cord size may be required due to voltage drop and advice must be obtained based upon installation details Any connectors or junction boxes must be specifically suited for outdoor use and installed in accordance with manufacturers instructions Any cable routed underground must be protected to local standards Cont 5 COMMISSIONING 5 11 The pump chamber mu
9. ou are in any doubt as to these rights please contact your local Trading Standards Department In the event of a claim please telephone PumpAssist or return the pump and flexible hoses with the accessories removed e g pipes etc If you have any doubt about removing a pump please consult a professional 44 0 844 98 000 97 Proof of purchase should accompany the returned unit to avoid delay in investigation and dealing with your claim You should obtain appropriate insurance cover for any loss or damage which is not covered by Stuart Turner Ltd in this provision Please record here for your records TYPE NO SERIAL NO DATE PURCHASED 14 NOTES 15 DECLARATION OF CONFORMITY 2006 95 EC BS EN 60335 1 BS EN 60335 2 41 EN 50366 2004 108 EC BS EN 55014 1 BS EN 55014 2 BS EN 55022 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 2011 65 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFACTURER STUART TURNER LIMITED HENLEY ON THAMES OXFORDSHIRE RG9 2AD ENGLAND Business Development Director Stuart Turner are an approved company to BS EN ISO 9001 2008 STUART TURNER Stuart Turner Ltd Henley on Thames Oxfordshire RG9 2AD ENGLAND Tel 44 0 1491 572655 Fax 44 0 1491 573704
10. position and ensure fully submerged Pump position When siting the pump ensure its base is raised slightly from the bottom of the sump reducing the possibility of blocking the filter with debris or drawing in small stones see Fig 2 CS Inlet filter area qm n p M f 2 16 If the pump is to be run continuously it must be installed in a vertical position and must be submerged at all times to avoid overheating of the motor 2 17 If the float switch is in use to empty a tank the pump may be operated partially submerged for short periods see float switch operation section for further details 2 18 Float Switch Operation All Diver models are fitted with a float switch for automatic operation 2 19 The following guide will help you get the most out of your pump 2 20 The pump must never run dry needing a minimum water depth of 300 mm at all times Cont 2 21 Adjustment of the float switch is achieved by lengthening or shortening the cable through the moulded cable retention slot which is located in the pump handle Figs 3 and 4 Note When inserting cable into slot ensure it is fully engaged Pump Handle Float Switch cable shown Fig 3 Moulded cable Fig 4 a slotted into position retention slot 2 22 If modification of the level setting is required refer to Figures 5 and 6 and the following c
11. st be full of water at all times Damage will result if pump runs dry 5 12 The pump must be fully submerged before starting Take care when submerging the pump to ensure all air is purged from the casing This is done by slowly submerging the pump and gently agitating whilst doing so This will enable any trapped air pockets to be released 5 13 Turn on the electrical supply and water movement should be immediately evident from pump outlet If it is not repeat step 5 12 Cont 10 6 MAINTENANCE 6 11 The water in and around the pump must not be allowed to freeze This will result in pump damage 6 12 Provision should be made for easy access to the pump to allow for regular maintenance 6 13 The integral inlet filter grille should be checked periodically and cleaned if required It is important the filters are clean and free from debris which in turn ensures the pump will always run at maximum efficiency A blocked filter can cause damage to the pump 6 14 The pump must be cleaned as follows 1 Disconnect electrical supply before working on pump 2 Release system pressure from pipework and remove pump from water do not use cable to lift pump 3 Clean integral inlet filter grilles using water pressure from a hose pipe Fig 9 4 Refer to commissioning section for instructions on re starting pump Cont 11 7 TECHNICAL SPECIFICATION Diver 35 Diver 45 Features Performance Min 4 C Max 35 C Control mo
12. vice Failure to install the unit in accordance with the installation instructions will lead to invalidation of the warranty STORAGE If this product is not to be installed immediately on receipt ensure that it is stored in a dry frost and vibration free location in its original packaging CONTENTS Page CUMS asad bee new Weel ene ep eoceved lt db hee Eaa er aceetee sue ene E 3 Important Facts read before commencing installation 4 EOCAUON cua pacerene cee E teed eee eee poe eee ET TET 5 Pump Connections c7 c5c etceucctencse eee seeebssese hee sweetest akan ees 7 Electrical Installation 2 2252 ok Osea enh eee Weed oe Se whe 62 SES Rew Sees ee Ss 8 COMMISSIONING i ines ood deat n e E E a AEE E sense weber emedeas 10 MaintenaNC O se seces chee ane yas wer ene etek ook eens weer ees 11 Technical Specification c 2n24cocgenbetins deheteoegsadudeagaun due aR 12 Trouble Shooting 52 2500 24 oeeonetem eta na EnEn Roe teens Ner EErEE 13 G arantee casita ed ences eos d oe aonb S in eek essee ee okteumees eases ess 14 CHECKLIST IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 hours of receipt m mA ten Deserotion a iem essen av Float switch part of pump B 25 mm Hose connector Your product may vary slightly from the picture above Cont IMPORTANT FACTS READ BEFORE