1. The day night arming modes are available if the installer has defined which zones are to be active in this armed mode If exit delay is programmed for a partition you can leave the partition through the exit route without triggering alarm after the partition arming procedure has started The exception is when the partition is armed without exit delay 6 3 1 Arming without partition selection Enter the code and then press to arm in full mode to arm in day mode to arm in night mode The partitions to which you have access will be armed 6 3 2 Arming with proximity card 1 Press any key on the VERSA LCDM WRL keypad to activate it 2 Bring the card close to the keys and hold it there for about 3 seconds The partitions to which you have access will be armed in full mode The reader in VERSA LCDM WRL keypad is enabled for 5 seconds after activating the keypad 6 3 3 Arming the selected partition 1 Indicate the partition which is to be armed press one of the keys 1 partition 1 partition 2 2 Select the arming mode press one of the keys full arming day arming G 4 night arming Backlight of the keys will start blinking which indicates that the code must be entered 3 Enter the code 4 Press the key or press again the key corresponding to the selected arming mode When the quick arming is available the steps 3 and 4 are skipped 12 VERSA IP SATEL 6 3 4 Quick arming The installer may
2. clear messaging 7 7 System state checking troubles checking partition alarm trouble status 8 8 Control controlling the outputs 9 9 Tests 91 1 Zone test starting zone test 92 2 Output test starting output test 93 3 Wireless sig checking the level quality of radio signal 94 4 Manual MS tst starting manual test transmission 95 5 MS1 test test of telephone reporting to station 1 96 6 MS2 test test of telephone reporting to station 2 97 7 VERSA version checking firmware version of control panel 98 8 Expander ver checking firmware version of system modules 99 9 Supply volt checking current supply voltage in modules 904 0 Outputs reset deactivating outputs activating 21 DETECTORS RESETTING output 0 0 Service 00 01 1 Start DwniTEL 034 KARNICE DIAN starting service mode starting programming via telephone communicator starting local programming 18 VERSA IP SATEL OE m4 FinishDwnlUSB finishing local programming 05 5 Serv access defining service code access rules 064 6 Access time defining service code access time 074 7 ETHM 1 gt DloadX starting programming via Ethernet 6 9 Change own code 1 Enter the user menu and press in turn A U 2 Enter the new code and then press 0 6 10 Users There can be up to 30 users in the system A person using the service code installer I service technician who is an additional user has
3. 6 6 Triggering the alarm from keypad 28 ected itt cain costes en RA AEO io AE 14 6 7 Tur ng the CHIME On off zza b AREA EEE 14 6 8 User MENU wawsee ne po EE AA C ADELE 15 6 8 1 Navigating through the menu and running FUNCTIONS eee centre eee eter aaa 15 6 8 2 Step by step programming method e eeee esse e eee aaa aaa aaa aaa aaa a aaaaar nei 15 6 8 3 Entering data zee aso adi wa R NRL a eee inca ARA AE Ad ees Ae rka sd 16 6 8 4 User functions liste e te ZO A R O EZ ARA ROA RAA eee 16 6 9 ChanaJE WNCOJE s lt sta tikai nad GAR R AE 18 0 107 MSS at eae te tate O kk Mio Od e E 18 6 10 1 Adding a USCM iii osi dzy si Ak A Z A do io ACE A at SLA 18 6 10 2 User e dtng zazna ES RE A AO EE OE eae ae ad 23 6 10 3 Removing AOST aka AOI A AE AI AREA A OA E EEE 25 6 11 Canceling the telephone messaging 22 ss eeeeeea aaa e ewa a aaa aaa aaa ak kiwa A SEE A 25 0 12 ZOME GY PASSING lt A ERA A RMA EEE A T 25 6 12 1 Zone DING s ze oO ah a Ga RAZ a R p dd op pacc 25 6 12 2 Zone ISOlAING iea a adCast Oda Pa yn P E Agia E 26 6 13 VIeWinGANe eveni OO tO NRA O OO ARA W A EA teats 26 6 14 Aulo armi ng deiermenl usa al Kao AP EWC 26 6 14 1 Simple auto arming deferment eee eee eee aaa aaa aaa aaa aaa 26 6 14 2 Auto arming deferment by means of function uuueeee aaa aaa aaa aaa aaa aaa 27 6 15 Setting the system time and date 2 assess ow zeeoaaa a een aa OOP
4. The symbols illustrate the following zone states the higher position on the list the higher priority of the presented state ki inhibited not displayed when armed b blinking isolated not displayed when armed LL long violated not displayed when armed i no violations not displayed when armed first triggered alarm ii tampered 2EOL type zone iit violated t tamper memory 2EOL type zone A alarm memory normal state If the global GRADE 2 option is enabled by the installer switching the display over to the zone status presentation mode key is impossible Irrespective of the selected mode the occurrence of specific events may result in the following information being displayed the higher position the higher priority of the status presented e countdown of auto arming delay e countdown of entry delay e countdown of exit delay e alarm from zone the message contains the name of zone which triggered the alarm and remains displayed until the alarm is cleared in case of alarm from several zones messages about successive alarms are displayed alternately every 2 seconds use the or key to scroll them through e alarm in partition the message contains the name of partition where the alarm occurred and remains displayed until the alarm is cleared if there is alarm in both partitions messages about the alarm are displayed alternately every 2
5. Warning alarm in some situations when the alarm criteria are met the alarm system does not take up immediately all the actions provided for in the event of alarm These actions are postponed reaction of the system being limited to signaling warning alarm in keypads proximity card arm disarm devices or on indoor sirens beacons Thus the user who made a mistake when entering the protected area failed to disarm the system before the entry delay expires or moving around the area when the day or night armed mode is activated violated the armed zone has some extra time to disarm the system Contact your installer to obtain detailed information on the situations when the alarm will be preceded by warning alarm Zone 1 a separated portion of the protected area that can supervised by a detector or detectors 2 the terminals on control panel expander electronics board to which you can connect a detector or another device whose state is to be supervised panic button siren tamper contact power supply output indicating loss of 230 V AC supply etc Zone bypassing inhibiting isolating procedure preventing the alarm from being triggered by the selected zone when it is in the armed mode Violations of the zone will be ignored by the control panel Zone violation a change of the zone status to another different from that defined for the normal state e g as a result of motion being sensed by the motion detector gas being sensed by
6. 100 keyfob Depending on the selected method enter the keyfob serial number and press HUD press twice any button on the keyfob displayed messages will prompt you what to do Numbering of the buttons and LEDs on the APT 100 keyfobs is described in section Operating the alarm system by means of keyfob p 33 17 Step 6c Assigning function to APT 100 keyfob button 1 Proceed in the same way as in Step 5c 18 Step 6d Assigning function to APT 100 keyfob button 2 Proceed in the same way as in Step 5c 19 Step 6e Assigning function to APT 100 keyfob button 3 Proceed in the same way as in Step 5c 20 Step 6f Assigning function to APT 100 keyfob button 4 Proceed in the same way as in Step 5c 21 Step 6g Assigning function to APT 100 keyfob button 5 Proceed in the same way as in Step 5c 22 Step 6h Assigning function to APT 100 keyfob button 6 two buttons pressed simultaneously 1 and 5 Proceed in the same way as in Step 5c 23 Step 6i Selecting confirmation for LED 1 in APT 100 keyfob Press to confirm the default method of confirmation defined by the installer in the user schedule or enter the number of one of the following functions and then press 0 On LED is on when the control panel has acknowledged receiving information on pressing a button Output 1 state LED is on when the selected output is active Output 2 state Output 3 state Output 4 state Output 5 state Output 6 state
7. Full armed mode the status in which all zones belonging to the partition are armed Installer the person who has installed and programmed the alarm system Medical auxiliary alarm alarm triggered by means of a button or from the keypad if it is necessary to call the medical assistance Night armed mode the status in which only some zones in the partition are armed as selected by the installer The installer should indicate the zones to be armed when a user stays in the protected area but there is no risk of the zones being violated by the user at night If no such zones are indicated by the installer the user will not be able to arm the partition in this mode Panic alarm alarm triggered by means of the panic button or from the keypad in case of a hold up Partition a part of the protected area composed of a number of zones The division into partitions makes it possible to limit the access to part of the premises to some selected users and to arm disarm the system only in part of the protected area Passive transponder a wireless device which has no power supply of its own but under the action of electromagnetic field it can emit a signal that enables the device to be identified It can have the form of proximity card proximity tag etc SATEL VERSA IP 5 Protected area the area supervised by detectors being part of the alarm system Proximity card a passive transponder that allows the user t
8. Output 7 state Output 8 state Output 9 state 10 Output 10 state 11 Output 11 state 12 Output 12 state 13 Arming Partition 1 LED is ON when partition 1 is armed O O NOO EO ND gt SATEL VERSA IP 23 14 Arming Partition 2 LED is ON when partition 2 is armed 15 Arming Partition 1 or 2 LED is ON when partition 1 or 2 is armed 16 Arming Partition 1 and 2 LED is ON when partitions 1 and 2 are armed 17 Partition 1 Full arm LED is lit when partition 1 is armed in full mode 18 Partition 1 Night arm LED is lit when partition 1 is armed in night mode 19 Partition 1 Day arm LED is lit when partition 1 is armed in day mode 20 Partition 2 Full arm LED is lit when partition 2 is armed in full mode 21 Partition 2 Night arm LED is lit when partition 2 is armed in night mode 22 Partition 2 Day arm LED is lit when partition 2 is armed in day mode 23 Partition 1 Alarm LED is ON when there is alarm in partition 1 24 Partition 2 Alarm LED is ON when there is alarm in partition 2 25 Partition 1 or 2 Alarm LED is ON when there is alarm in partition 1 or 2 26 Trouble LED is ON when there is trouble in the system 255 NOT PRESENT Contact the installer to obtain information on the zone types and output functions LED will not be used for confirmation 24 Step 6j Selecting confirmation for LED 2 in APT 100 keyfob Proceed in the same way as in Step Gi 25 Step 6k S
9. Programming timer activation deactivation time on Tuesday Proceed in the same way as in Step 3 3 Step 5 Programming timer activation deactivation time on Wednesday Proceed in the same way as in Step 3 28 VERSA IP SATEL 4 Step 6 Programming timer activation deactivation time on Thursday Proceed in the same way as in Step 3 5 Step 7 Programming timer activation deactivation time on Friday Proceed in the same way as in Step 3 6 Step 8 Programming timer activation deactivation time on Saturday Proceed in the same way as in Step 3 7 Step 9 Programming timer activation deactivation time on Sunday Proceed in the same way as in Step 3 8 Step 10 Programming timer activation deactivation time on every day of the week Proceed in the same way as in Step 3 After pressing HD you will be taken back to Step 2 6 16 2 Programming an exception The exception is a period when the timer will be activated deactivated at a different time than provided for by the weekly schedule The programming is carried out in the same way for each of the four exceptions 1 Step 3 Programming the date from which the exception will be valid Enter the year only the two last digits month and day Press to confirm the data and go on to the next step 2 Step 4 Programming the date to which the exception will be valid Proceed in the same way as in Step 3 3 Step 5 Programming the timer activation deactivation time when the exception is
10. The voice menu makes the operation an easy job To access the voice menu call the phone number of the control panel The installer can make the option of operating the system by phone conditional on the partition state the operation being only possible when the selected partitions are armed 8 1 Starting the operating by telephone 1 Call the control panel phone number After the call is received you will hear three short beeps The installer can configure the control panel in such a manner that the telephone communicator will only go off hook after the recall If this is the case call the number but hang up after the number of rings which has been set by the installer Call again within three minutes The call will be received 2 Enter the code from the telephone keypad and confirm by pressing 4 short beeps followed by 1 long beep will confirm you have got access to the interactive voice menu If your code does not authorize you to get access you will hear three long beeps in the headset If the code is incorrect you will hear two long beeps in the headset After a wrong code is entered three times the control panel will hang up and for the next 90 seconds it will be impossible to establish connection with the control panel SATEL VERSA IP 37 3 Messages of the interactive voice menu will be played back They will inform you which telephone keys you should use to be able to operate the control panel 8 2 Voice menu
11. by running the EXPANDER VER function in the keypad see Checking the firmware version of modules p 32
12. by the magnetic contact The keypad should inform you that the zone has been violated the zone symbol changes to 1 Information on the violation will be presented until the zone test is terminated 4 The test will be terminated automatically after the defined time has elapsed You can terminate it earlier by pressing 6 21 2 Output test The function makes it possible to check proper functioning of the system outputs as well as devices connected to them You can always test 12 outputs 32 VERSA IP SATEL 1 Enter the user menu and press in turn wx Pac ID The keypad will present the state of outputs in the upper line of the display output inactive i output active The name of output over which the cursor is currently situated is displayed in the lower line The EB gt and Gl 4 keys allow moving the cursor 2 Press to activate the output or to deactivate the output 3 Press k w to quit the function 6 21 3 Checking the level quality of radio signal The function allows you to check e the quality of radio signal received by the controller from 433 MHz wireless detectors if the VERSA MCU controller is connected to the control panel e the level of radio signal received by the controller from ABAX wireless devices if the ABAX system controller is connected to the control panel Enter the user menu and press in turn Bwxuz Baer IJ In the lower line of the display the inform
13. clear alarms 9 clear alarms main menu 7 troubles you can play back information on the troubles clear trouble memory 8 make system restart 9 clear troubles memory main menu 8 outputs you can play back information on the state of 15 CONTROLLED function output activate or deactivate the output enter the output number and press if only one output is available this step will be skipped 1 switch on 6 switch off 0 another output next output main menu 8 3 Ending the operating by telephone 1 Press key 2 Press in turn the O keys The control panel will go on hook The control panel will goes on hook automatically after one minute of idle state 9 Acknowledgement of voice messaging A special 4 digit code is used to acknowledge messaging see Programming codes to acknowledge clear messaging p 29 Having received voice messaging enter the code from the telephone keypad The messaging acknowledgement will cancel telephone notification of the event The installer can configure the control panel so that the user after acknowledgement of voice messaging should automatically get access to the interactive voice menu see Operating the alarm system by telephone p 36 10 VERSA Control application The VERSA Control is a mobile application that allows you to remotely operate your alarm system i e e arm disarm the system or clear alarm e
14. in partition 1 35 Arming partition 2 full armed mode 36 Arming partition 2 night armed mode 37 Arming partition 2 day armed mode 38 Disarming clearing alarm in partition 2 39 Arming partitions 1 and 2 full armed mode 40 Arming partitions 1 and 2 night armed mode 41 Arming partitions 1 and 2 day armed mode 42 Disarming clearing alarm in partitions 1 and 2 43 Loud panic alarm 44 Silent panic alarm 45 Fire alarm 46 Medical alarm OMNAARWNAO SATEL VERSA IP 21 51 Output 1 activation 52 Output 2 activation 53 Output 3 activation 54 Output 4 activation 55 Output 5 activation 56 Output 6 activation 57 Output 7 activation 58 Output 8 activation 59 Output 9 activation 60 Output 10 activation 61 Output 11 activation 62 Output 12 activation 71 Output 1 deactivation 72 Output 2 deactivation 73 Output 3 deactivation 74 Output 4 deactivation 75 Output 5 deactivation 76 Output 6 deactivation 77 Output 7 deactivation 78 Output 8 deactivation 79 Output 9 deactivation 80 Output 10 deactivation 81 Output 11 deactivation 82 Output 12 deactivation 91 Output 1 switchover 92 Output 2 switchover 93 Output 3 switchover 94 Output 4 switchover 95 Output 5 switchover 96 Output 6 switchover 97 Output 7 switchover 98 Output 8 switchover 99 Output 9 switchover 100 Output 10 switchover 101 Output 11 switchover 102 Output 12 switchover Contact the installe
15. permit arming without entering the code 1 Indicate the partition s to be armed press one of the keys 1 partition 1 partition 2 Saer or O both partitions 2 Select the arming mode press one of the keys full arming day arming 4 night arming You can switch the arming mode from the night mode to the full mode and from the day mode to the full mode without entering the code Otherwise you will have to enter the code see Arming the selected partition The installer can configure the system so that the quick arming can be impossible if there is a violated zone in the partition or a trouble has occurred in the system 6 3 5 Arming without delay When arming the system using one of the above mentioned methods press and hold down the arming mode selection key E 4 E3 gt or G 4 for about 3 seconds The system will become armed without delay i e the delayed zones will act as instant ones without any exit entry delay time 6 3 6 Information about bypassed zones During an arming attempt you may get a message about bypassed zones in the partition The information will be displayed if e the control panel has been suitably configured by the installer e you have the INSPECTION right The message is displayed in the following form Bypassed zones 1 Arm 4 Bypasses if you have the ZONE INHIBITION right You can press the W key to cancel the arming p
16. seconds in the first and second partition use the or key to scroll them through e there was a tamper and the service must be called in the message is displayed until trouble memory is cleared by a person using the service code see Trouble memory and clearing the trouble memory p 30 If the GRADE 2 global option is enabled by the installer the messages on alarms and tampers are not displayed SATEL VERSA IP 9 The keys bearing digits and letters enable entering the code as well as data when the keypad is being used Other functions of these keys and the basic function of the other keys are described below O allow to trigger the medical aux alarm press and hold down for 3 seconds allow to turn on off the CHIME signal in the keypad press and hold down for 3 seconds Guxyz allow to toggle the LCD keypad display between the normal mode and the zone state presentation mode press and hold down for 3 seconds allow to arm in the full mode if the system is disarmed and there is no alarm or disarm the system and clear the alarm if the system is armed and or there is an alarm enter the code and press HD trigger the panic alarm press and hold down for 3 seconds s ij Fle allow to open the user menu enter the code and press w trigger the fire alarm press and hold down for 3 seconds allow to arm in the full mode see Arming allow to arm in th
17. the code must be entered 3 Enter the code 4 Press the E3 V or key 6 4 4 Viewing the zones which triggered alarm Having cleared the alarm you can check which zones triggered the alarm this does not apply to the TMP zone of the control panel The information will be available until viewing the zones or arming the system 1 Enter the code and press w 2 The View cleared zones 1 Yes will appear on the display Press a 3 The list of zones which triggered the alarm will be displayed 4 Having viewed the list press w the user menu will be displayed 6 5 Quick inspection of partition status If such an option is provided by the installer pressing and holding down the key for about 3 seconds will display information on the partition state whether it is armed and what type of arming mode is set At the same time the TA LED will come on In the upper line a message about the first partition state is displayed and in the lower line about the second partition state To terminate the function of partition state presentation press w The keypad will quit the function automatically after 2 minutes 6 6 Triggering the alarm from keypad The installer can permit triggering alarms from the keypad To trigger an alarm do the following fire alarm press k w for approx 3 seconds medical auxiliary alarm press for approx 3 seconds panic alarm press for approx 3 seconds T
18. the gas detector etc 5 Control panel compliance with EN 50131 standard requirements for Grade 2 If the installer has configured the control panel in compliance with the EN 50131 standard requirements for Grade 2 1 The user codes should be composed of at least 5 characters 2 The amount of information provided in the keypads by means of LEDs display and sound signaling is limited 6 VERSA IP SATEL 3 The quick arming from keypad without entering the code is not available 4 Arming may be impossible if one of the situations provided for in the standard occurs zone violation trouble How requirements of the standard affect the use of the control panel is described in detail hereunder 6 Operating the alarm system with LCD keypad OO OO VE OO OO Fig 1 VERSA LCDM keypad the VERSA LCDM WRL keypad differs only in some graphic elements on its glass 06 0 Fig 2 VERSA LCD keypad SATEL offers the following LCD keypads for VERSA IP control panels VERSA LCDM hardwired keypad VERSA LCDM WRL wireless keypad VERSA LCD hardwired keypad SATEL VERSA IP 7 The keypads are available in a variety of color options for the display and key backlight The color variant is indicated by the additional designation in the keypad na
19. valid Enter the data in the same way as for programming the timer activation deactivation in the weekly schedule After pressing U you will be taken back to Step 2 6 16 3 Selecting the arming mode 1 Define whether and what arming mode is to be activated by the timer press one of the keys A full arming night arming day arming Ai timer does not arm the partition 2 Press HD You will be taken back to Step 2 6 17 Programming the telephone numbers to be notified 1 Enter the user menu and press in turn Bmro ani D 2 Press in turn the suitable keys to select the telephone number to be edited the phone numbers to which voice messaging is not enabled are only available to the installer 1 _ 0 telephone 1 Pac F D telephone 2 der 0 telephone 3 4an GB telephone 4 Sm telephone 5 Gmrc D telephone 6 pars D telephone 7 Bzz Ol telephone 8 3 Enter the telephone number the available characters are presented in Table 4 You can enter up to 16 characters Some of the characters occupy two positions a b c d and If they are used you can enter less characters than 16 In the upper line on the right side of the display you can find information on the letter case ABC or abc it is SATEL VERSA IP 29 displayed after you press any key and remains on the screen for a few seconds afte
20. weather During storms the devices connected to the electrical system or telephone line are vulnerable to damage as a result of atmospheric discharge The control panel is provided with a number of safeguards and automatic diagnostic features to test the system performance Detection of irregularities is signaled by the A LED on the keypad You should immediately respond to such a signal and if necessary consult the installer In addition some features designed for testing the alarm system are available in the control panel They make it possible to check the detectors sirens telephone communicators etc for correct functioning Only regular testing and inspection of the alarm system will allow you to keep a high level of protection against intrusion It is recommended that the installer at the request of the user carry out periodic maintenance of the alarm system It is in the interest of the user to anticipate and plan in advance the procedures in case an alarm is set off by the control panel It is important to be able to verify the alarm determine its source and take appropriate actions e g evacuation in the event of a fire alarm 3 Alarm system operating costs The control panel can inform the users and the monitoring station about the status of protected facility Realization of these functions by means of the phone line means financial costs The amount of the costs incurred depends on the amount of information sent A failur
21. 8 3 Enter a 4 digit code and then press U 6 19 Checking the troubles system state When the TA LED is blinking you can check what caused this signaling Enter the user menu and press in turn FO To scroll through the list use the cv and 4 keys 6 19 1 Information on system state If the GRADE 2 option is enabled by the installer the following information will be displayed e partition alarms e alarms from zones e bypassed zones e troubles e partition state disarmed or arming mode The higher position the higher priority of the state 6 19 2 Trouble handling procedure Each trouble poses a danger to proper functioning of the alarm system and should be repaired as soon as possible If necessary consult the installer In the event of failure of the control panel processor system HSE when you have exited the 7 SYSTEM STATE function by using the w key the Make VERSA panel restart 1 Yes message will be displayed Pressing the 1 key will restart the control panel and repair the trouble 6 19 3 Trouble memory and clearing the trouble memory The installer defines whether only the current troubles are to be presented or also those which have already ended The flashing letter M in the upper right corner of the display means that the trouble has already ended You can clear the trouble memory after quitting the function 1 Press k w to quit the function The Clear tro
22. EA A GADA EWA 27 6 16 Programming the timer S i R BRA REAR no EWA A AREA nieces 27 6 16 1 Programming the weekly schedule eee teeter ee aaa aaa tees ee aaa aaa 27 6 16 2 Programming an exception ue di Oni Ad ew A ane di BE 28 2 VERSA IP SATEL 6 16 3 Selecting the arming MOJE s O erae a denned aaa of aaa w dka 28 6 17 Programming the telephone numbers to be notified eeeeeeeeeeaaaa aaa aaaaaaaaae 28 6 18 Programming codes to acknowledge clear messaging euueaeaa aaa eaaaaniaaae 29 6 19 Checking the troubles system state 4 4 2 44 uu0 omen azer aaa A EEEE 30 6 19 1 Iniormation on systeni stale u nai NO O A i a R AE Wad W EOB 30 6 19 2 Trouble handling procequre ae i AA OZ YJ A dk TY AE SAI Za 30 6 19 3 Trouble memory and clearing the trouble memory ee eee eee aaa aaa aaa aaa iaai ai iA 30 6 20 OufputcontTolkat 2 sec ip ZE o Ea dE dada Taa ta Bat SZR Me soaleeareuis 30 6 20 1 Quick control of QUIDU S icena tyko A zela a a a dwa a TAEA 30 6 20 2 Controlling the outputs by means of function uuueee saa eee aaa aaa aaa 31 6 21 TESS cu ton O fo A Z lea kod dd 31 6 21 1 Zone Este z A A A O dot akad a OO EA OE 31 6 21 2 Output tests say ad OE ee Ad AO a aw SO A SEL ees 31 6 21 3 Checking the level quality of radio signal ee esa a eee aaa aaa aaa aaa aaa 32 6 21 4 Starting
23. Press to activate the output or to deactivate the output If you want to see the status of all outputs you can control press ES gt or SG 4 The numbers around the display enable identification of the outputs Use the and keys to move the cursor Having hovered your cursor over the output you can activate it by pressing or deactivate it by pressing 0 If you want to restore the previous way of presentation of the output list press or B 4 6 21 Tests 6 21 1 Zone test The function enables checking the system zones and detectors connected to them for proper functioning You can test the zones for which the installer has programmed other wiring type than NOT USED Zone violation during the test will not trigger the control panel reaction as preprogrammed for the zone When testing the zones the keypad does not present the current zone state but only indicates whether or not the zone was violated during the test 1 Enter the user menu and press in turn Gwxuz 1 U 2 Enter two digits to define the test duration e g if the time is to be 5 minutes press in turn 0 and Sm the test may last from 1 to 15 minutes and then press HD The keypad will indicate the zones which can be tested using the symbol the numbers around the display enable identification of the zones 3 Violate the selected zones e g walking through the area supervised by the motion detector or opening the window supervised
24. Saged d USER MANUAL lt o 14 Tr gt ro C U OW ro Cc O O lt x SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 58 320 94 00 www satel eu versa_ip_u_en 07 15 WARNING Before you start using the control panel please read carefully this manual in order to avoid mistakes that can lead to malfunction or even damage to the equipment Changes modifications or repairs not authorized by the manufacturer shall void your rights under the warranty The control panels should only be connected to the analog subscriber lines In case of changing the analog line to the digital one it is necessary to contact the alarm system installer Pay special attention if the telephone line used by the control panel is frequently busy and or failures are reported concerning the line and or monitoring Report such situations to the alarm system installer immediately To ensure adequate protection the alarm security system must be in good working order therefore SATEL recommends that it be regularly tested The control panel is equipped with a number of self diagnostic functions which when properly configured by the installer ensure control over correct functioning of the system The alarm security system cannot prevent burglary assault or fire from happening but it guarantees that in case of emergency measures will be taken to reduce the possible damage the alarm will be signaled optically and
25. Some zones in the partition are violated or there is a trouble 2 long beeps incorrect code card or pressing the w G34 lt ES gt or EIV key if not preceded by entering code or selecting a partition 3 long beeps refusal to carry out a command the user does not have the required authority level or the function is not available Beeps generated during programming 1 short beep pressing any number key 2 short beeps entering the user menu submenu or a function or going to a next programming step 3 short beeps end of timer parameters editing exiting the service function on pressing the key 4 short beeps and 1 long beep termination of the user function on pressing the key or quitting the service mode 2 long beeps exiting the function on pressing the w key or an unavailable function Events signaled by sounds Only installer selected events are signaled Duration of the alarm signaling is to be defined by the installer If the GRADE 2 option is enabled by installer the keypad will not signal by sounds any new troubles and alarms 5 short beeps zone violation CHIME Long beep every 3 seconds followed by a series of short beeps for 10 seconds and 1 long beep countdown of exit delay if the time is shorter than 10 seconds only the final sequence of short beeps will be generated A sequence of 7 beeps of diminishing duration repeated every few seconds countdown of a
26. The structure of voice menu is shown below Pressing the key will always take you back to the main menu 1 macros you can run a macro or an installer defined sequence of actions which is to be executed by the control panel enter the macro number and press if only one macro is available this step will be skipped 1 execute 7 execute despite obstacles 0 another macro next macro main menu 2 partitions you can play back information on the state of partition arm disarm the partition clear alarm in the partition enter the partition number and press if only one partition is available this step will be skipped 1 arm in full mode 2 arm in night mode 3 arm in day mode 6 disarm 7 arm despite obstacles 9 clear alarms 0 another partition next partition main menu 3 listen if the INT AVT terminal is connected to the control panel you can use the listen in function and talk to the people staying in the premises 2 bidirectional 3 loud 6 quietly main menu 4 zones you can play back information on the state of zone bypass unbypass the zone enter the zone number and press if only one zone is available this step will be skipped 1 inhibit 2 isolate 6 unbypass 38 VERSA IP SATEL 0 another zone next zone main menu 5 alarms you can play back information on the alarms
27. a special status but his her access can be limited see Defining the service access rules p 33 and Defining the service access time p 33 6 10 1 Adding a user 1 Enter the user menu and press in turn Zac 1__ 3 GD Adding the user is effected by the step by step method hence the programming step number is presented on the and r LEDs of the first and second partitions see page 15 Table 1 You can press k w to interrupt the procedure of adding a user If the procedure is interrupted in step 5 or a next one the code user schedule and partitions have been already assigned to the user the user will be added 2 Step 2 Entering new user code Information on the number of the user to be added is presented in the display upper line Enter the new user s code and then press U 3 Step 3 Selecting user schedule Five installer defined schedules are available The schedule determines the user s rights and the default operating mode of the remote control keyfobs assigned to the user the keyfobs are added in subsequent steps Press the key bearing the digit corresponding to the schedule which is to be assigned to the user The name of selected schedule will appear in the lower display line Press to confirm your selection SATEL VERSA IP 19 Arming Schedule name and number lt e Arm only Disarming DANAN gt DURESS SISI S E G Alarm clearing Tel
28. acoustically appropriate services will be notified etc which may deter the potential burglars The SATEL s goal is to continually upgrade the quality of its products which may result in alterations of their technical specifications and firmware The current information on the introduced modifications is available on our website Please visit us http www satel eu The declaration of conformity may be consulted at www satel eu ce Factory default codes Service code 12345 User 30 code 1111 The following symbols may be used in this manual note A caution oo SNS CONTENTS Introduction nea ciaze sia dz we aae Sd ee ii eos 3 Technical reliability of the alarm system eeeeaaaaa aaa a nnn zzaeaaaaaaaaaaannzzzznnn0 3 Alarm system operating costs ssssssaanneneeenena znana aaa nzzzaaaaaaaaaaaaaanaazza naa ennn 3 OS SAY awa O O R AA WW AA O nce ns O avo cat oc e een eee ce ee ee 4 Control panel compliance with EN 50131 standard requirements for Grade 2 5 Operating the alarm system with LCD keypad ccccssssseeeeesseeeeeeeesseneeeeenseeseeeeenes 6 6 1 Keypads description e ae a ra AE A EOKA EO APE A A dE w EA KALE 7 6 1 1 LEDs presenting partition and system state uuuuee eau aaa aaa aaa 7 6 1 2 BISPIAY Gaz zaa da a IA anced tees SEAS da Zi Al ad ES AAAA ZPW AA PR BO ORA dus 8 6 1 3 RYS az A kW Not APR YO O w O a OE 9 6 1 4 Built in proxi
29. ation on signal level quality will be shown The upper line displays the name of zone to which the wireless device is assigned Use the arrow keys to scroll through the list 6 21 4 Starting the manual test transmission Enter the user menu and press in turn Gwxuz 4ani GO A Manual reporting test event will be saved to the control panel memory The event code will be sent to the monitoring station 6 21 5 Telephone reporting test Enter the user menu and press in turn Bwuz 5w D test of telephone reporting to Station 1 or test of telephone reporting to Station 2 Messages with information on the currently realized operations will appear on the display This allows problems if any to be diagnosed 6 21 6 Checking the firmware version of control panel Enter the user menu and press in turn U Information on the control panel firmware version and build date will be displayed 6 21 7 Checking the firmware version of modules Enter the user menu and press in turn Bwxz Btw D Information on the firmware of module with the lowest address will be displayed the module name in the upper line and the firmware version and build date in the lower line You can scroll through the list of modules using the EJY and 64 keys In the case of the built in Ethernet module pressing the EDITE ES gt or G lt key will display additional information IP address MAC address individual identification numbe
30. bypass unbypass the zones e control the outputs e view the event log SATEL VERSA IP 39 e view the troubles Additionally the application can provide information on the alarm system events by using push notifications You can download the application from the internet stores Google play Android system devices or App Store iOS system devices sz VeSa iy CONTROL Add new system Event notification service Alarms Arming and disarming Zone bypasses Diagnostics troubles restarts Other Fig 6 VERSA Control application configuring the control panel settings Having installed the application e enter the name of control panel to enable identification of the control panel when using the application e enter the MAC address of control panel the hardware address of built in Ethernet communication module e enter the ID number of control panel the individual identification number for the purpose of communication via the SATEL server e enter the user code which will be used when operating the control panel by means of the application 40 VERSA IP SATEL e select an icon for the control panel to facilitate identification of the control panel when using the application e enable disable the push notifications of the alarm system events if you enable the push notifications select the events about which you want to be informed You can check the MAC address and ID
31. e esse eee saa eee eee aaa eee e nawa aan aa oc aat pea aaAA 38 9 Acknowledgement of voice MESSAGING ssssssssannnneneeanaa nana aaanzzzaanaaaaana0e 38 10 VERSA lt GonttoFeppIICALOM iGol zk obawie 38 SATEL VERSA IP 3 1 Introduction Thank you for choosing the product offered by the SATEL Company Wishing you full satisfaction with the choice you made we are always ready to provide you with professional assistance and information on our products The SATEL Company is manufacturer of a broad range of devices dedicated for use in security alarm systems Further information is available on our website www satel eu or at the points of sale offering our products This manual describes various ways of operating the alarm system except by using the LED keypad and the INT TSG keypad the description of which can be found in separate manuals It is recommended that that the installers prepare their own user manual for the alarm system installed by them The manual must include all changes and modifications in relation to the factory default settings The installer should train the users in the rules of operating the alarm system 2 Technical reliability of the alarm system A failure of any component of the alarm system will result in deterioration of the level of protection Unfortunately the devices which are installed outside e g the outdoor sirens are exposed to the adverse effects of
32. e of telephone links as well as an incorrect programming of the control panel may result in increased costs due to making of excessive number of calls Please inform the installer which is a priority to deliver information at any cost or to prevent excessive costs For example after an event code has failed to be sent successfully to the monitoring station the control panel may repeat attempts every few minutes to send the code or to cease the attempts to send the code until a next event occurs 4 VERSA IP SATEL 4 Glossary Alarm reaction of the alarm system to detection by the detectors of an intruder in the protected area or to another event within the protected area e g glass pane break gas detection etc The alarm can be signaled in keypads proximity card arm disarm devices or by sirens during a defined time or until cleared Additionally information on the alarm can be sent to the monitoring station or the user Alarm zone the zone whose violation can result in the alarm being triggered The alarm zones can be either instant violation will trigger the alarm at once or delayed violation will only trigger the alarm after a defined period of time has elapsed e g the entry delay Armed mode the status of alarm system in which zone violation will trigger the alarm Code a sequence of digits that allows the user to operate the alarm system by using keypad Day armed mode the status in which only
33. e by using the service code Enter a new value from the range of 0 to 255 hours and press 7 Operating the alarm system by means of keyfob The alarm system can be operated by means of keyfobs if the 433 MHz keyfobs receiver expansion module INT RX S INT RX 433 MHz wireless system controller VERSA MCU or ABAX wireless system controller ACU 120 ACU 270 ACU 100 ACU 250 is connected to the control panel 34 VERSA IP SATEL The user can have two keyfobs e 433 MHz keyfob supported by the 433 MHz keyfobs receiver expansion module or 433 MHz wireless system controller e APT 100 bidirectional keyfob supported by the ABAX wireless system controller A single keyfob enables up to 6 functions to be executed The list of functions assigned to the buttons combination of buttons should be obtained from the person who configured the keyfob settings when adding editing a user In the case of APT 100 keyfob that person should also provide information about functionality of the LEDs The keyfob LEDs can be used to confirm execution of functions as well as to indicate the system status pressing a button on the APT 100 keyfob is accompanied by the LEDs flashing rapidly three times and in a little while the LED s may come on for 3 seconds to provide information The installer can configure the alarm system so that the sirens connected to the system outputs can inform the user about the following events 1 tone sta
34. e night mode see Arming allow to arm in the day mode see Arming ace el allow to disarm the system and clear the alarm see Disarming and alarm clearing quickly check the partition state press and hold down for 3 seconds 6 1 4 Built in proximity card reader The VERSA LCDM WRL keypad has a built in proximity card reader The reader enables arming disarming and alarm clearing by means of proximity cards proximity tags or other 125 kHz passive transponders 6 1 5 Sound signaling The installer can disable the sound signaling Beeps generated when operating 1 short beep pressing any number key 3 short beeps confirmation of starting the arming procedure there is exit delay in the partition or arming there is no exit delay in the partition disarming and or alarm clearing selecting the partition which is to be armed or disarmed or where alarm is to be cleared in such a case the keypad is waiting for the code to be entered turning output off turning off the CHIME in the keypad using the key switching over the display from the normal mode to the zone status presentation mode and vice versa by means of the key 10 VERSA IP SATEL 4 short beeps and 1 long beep confirmation of turning output on turning on the CHIME in the keypad using the key 1 long beep some zones are bypassed when arming or denial of arming
35. e rules of confirmation the procedure is similar as for defining the rules of confirmation after an APT 100 keyfob has been added to a new user 8 Step 7 Editing proximity card Press HD if you want to move on to the next step SATEL VERSA IP 25 1 and in turn if you want to add a card the procedure is much similar to that for adding a card to a new user and HD if you want to remove a card 9 Step 8 Editing user name Proceed in the same way as when adding a new user 6 10 3 Removing a user 1 Enter the user menu and press in turn anc Baer D 2 Select the user who is to be removed You can make your selection by scrolling through the list of users by means of the and keys or entering the user number Having selected the user press Ol 6 11 Canceling the telephone messaging The telephone messaging can be cancelled together with alarm clearing if such an option is provided by the installer The telephone messaging is cancelled after acknowledgement of the voice messaging see Acknowledgement of voice messaging p 38 Enter the user menu and press in turn HD 6 12 Zone bypassing If a zone is not to trigger alarm you can bypass it when the partition to which the zone belongs is disarmed Zone bypassing is useful for example when you want to leave a window open when the system is armed or when a detector connected to the zone is out of order and sets off false alarm
36. e zone is to be inhibited the zone is to be unbypassed If you want to see the status of all zones which you can inhibit unbypass press or ad The numbers around the display enable identification of the zones Use the and a 4 keys to move the cursor To inhibit unbypass a zone hover the cursor over it and press any numeric key If you want to restore the previous way of presentation of the zone list press E3 V or GDA Press to quit the function The zones will be inhibited unbypassed 6 12 2 Zone isolating The isolated zone will remain bypassed until it is unbypassed by the user Enter the user menu and press in turn aoni Pane D The way of indicating the zone state and the procedure are identical to those used for inhibiting the zones but pressing any number key will change the displayed symbol to one of the following symbols ii the zone is to be isolated the zone is to be unbypassed 6 13 Viewing the event log Enter the user menu and press in turn ED The last event that occurred in the system will be displayed The event description includes the time of its occurrence its name and additional information e g the partition in which the event took place the zone which caused the event etc The additional information appears automatically a few seconds after the event is displayed Press GQ 4 or EBP for the additional information to be displayed sooner To scroll through the event log u
37. electing confirmation for LED 3 in APT 100 keyfob Proceed in the same way as in Step Gi Pressing the w key between Step 6a and 6k will cancel the keyfob adding but will not terminate the user adding procedure 26 Step 7 Adding proximity card If a device provided with proximity card reader is installed in the system a proximity card can be assigned to the user Press in turn and if a proximity card is to be assigned to the user or only if no proximity card is to be assigned to the user 27 Step 7a Selecting card addition method Press if the card code is to be entered or select the device by means of which the card code will be read Use the E3Y and DA keys to scroll through the list of devices Having selected the device press D 28 Step 7b Adding proximity card Depending on the selected method enter the card code see Entering hexadecimal characters p 16 and press U bring the card twice close to the reader displayed messages will prompt you what to do Remember that the card number will only be sent by the proximity card arm disarm device after the card is moved away from the reader Pressing the wj key in Step 7a or 7b will cancel the card adding but will not terminate the user adding procedure 29 Step 8 Giving name to user Enter the user name see Entering names p 16 and press 6 10 2 User editing 1 Enter the user menu and press in turn atc anc D Us
38. ephone messaging clearing Auto arming defer lt A AAA lt BR Zone inhibition Zone isolation Change access code v v Users editing Control w w Programming DOWNLOAD SERWIS w Inspection Tests NEN DNDN ENN DNDN A SASA OF Administrator DURESS INT VG access s Table 3 Factory default settings of the user schedules The installer can change the names 4 7 of schedules and assign other rights to them Using the DURESS right code will trigger a silent alarm which is not signaled in any way but the alarm code will be sent to the monitoring station Step 4 Selecting partitions accessible to the user Press the key a partition 1 partition 2 or both partitions to define the partitions to which the user is to have access Information on the selected partition s will appear in the lower display line Press to confirm your selection Step 5 Adding 433 MHz keyfob If the INT RX S INT RX or VERSA MCU module is connected to the control panel the user may be assigned a 433 MHz keyfob Press in tun 1 Jand D if a keyfob is to be assigned to the user or only if no keyfob is to be assigned to the user Step 5a Selecting 433 MHz keyfob addition method Press if the keyfob serial number is to be entered or press in turn 1 if the serial number is to be read by the device whic
39. er editing is effected by the step by step method hence the programming step number is presented on the gt and r LEDs of the first and second partitions see page 15 Table 1 24 VERSA IP SATEL 2 Step 1 Selecting user whose data are to be edited You can make your selection by scrolling through the list of users by means of the E3Y and GDA keys or entering the user number Having selected the user press You can press wj to interrupt the procedure of editing a user Any changes made in the steps ended by pressing the key will be saved 3 Step 2 Changing user code Proceed in the same way as when adding a new user Step 3 Selecting user schedule Proceed in the same way as when adding a new user 5 Step 4 Selecting partitions accessible to the user Proceed in the same way as when adding a new user 6 Step 5 Editing 433 MHz keyfob Press if you want to move on to the next step i 1 and Din turn if you want to add a keyfob the procedure is similar to that for adding a 433 MHz keyfob to a new user however if the user had a keyfob before the control panel during assignment of functions to the buttons will suggest the same functions as were assigned to the removed keyfob Babc and ID in turn if the user has a keyfob and you want to edit functions assigned to the keyfob buttons the procedure is similar to that for assigning functions after a 433 MHz keyfob has been added
40. h supports the keyfobs during transmission Step 5b Adding 433 MHz keyfob Depending on the selected method enter the keyfob serial number and press HHD press twice any button on the keyfob displayed messages will prompt you what to do Numbering of the buttons in 433 MHz keyfobs is described in section Operating the alarm system by means of keyfob p 33 20 VERSA IP SATEL 8 Step 5c Assigning function to 433 MHz keyfob button 1 Press to confirm the default function defined by the installer in the user schedule or enter the number of one of the following functions and then press Not used Zone 1 violation Zone 2 violation Zone 3 violation Zone 4 violation Zone 5 violation Zone 6 violation Zone 7 violation Zone 8 violation Zone 9 violation 10 Zone 10 violation 11 Zone 11 violation 12 Zone 12 violation 13 Zone 13 violation 14 Zone 14 violation 15 Zone 15 violation 16 Zone 16 violation 17 Zone 17 violation 18 Zone 18 violation 19 Zone 19 violation 20 Zone 20 violation 21 Zone 21 violation 22 Zone 22 violation 23 Zone 23 violation 24 Zone 24 violation 25 Zone 25 violation 26 Zone 26 violation 27 Zone 27 violation 28 Zone 28 violation 29 Zone 29 violation 30 Zone 30 violation 31 Arming partition 1 full armed mode 32 Arming partition 1 night armed mode 33 Arming partition 1 day armed mode 34 Disarming clearing alarm
41. he installer defines whether the loud panic alarm setting off the loud alarm signal or the silent panic alarm without the loud signal will be triggered 6 7 Turning the CHIME on off The CHIME is five short sounds by means of which the keypad will inform you e g that a door window is open when the system is disarmed The installer defines which zones of the alarm system can trigger the CHIME and whether it can be turned on off by the users Press and hold down for about 3 seconds to turn on or off the CHIME signaling SATEL VERSA IP 15 6 8 User menu Enter the code and press k w to get access to the user menu The functions you can run will be displayed The list of available functions depends on your rights as well as on the state and configuration of the system In order to quit the function and or user menu press k w The keypad will quit the menu automatically if 2 minutes have elapsed since the last keypress 6 8 1 Navigating through the menu and running functions Using the arrow keys 1 Using the and keys find the required submenu or function The currently selected submenu or function is indicated by the cursor on the left the submenu indicating cursor the function indicating cursor 2 Press E3 gt or GD to open a submenu or run a function use the key to go back to the previous menu submenu Using the digit shortcuts All submenus and functions are numbered In order to enter a
42. isabled Press any number key to enable disable the option If you want to see the status of all options press E3 gt or GQ 4 The numbers around the display allow the options to be identified Use the and keys to move the cursor To enable disable an option hover the cursor over it and press any numeric key If you want to restore the previous way of presentation of the list of options press ESY or B 4 Press to confirm the changes made and quit the function Description of the options The order of describing the options corresponds to their numeration in the keypad Permanent access if the option is enabled the service code can be used to get access to the alarm system at all times A If the alarm system is to meet requirements of the EN 50131 standard for Grade 2 the service code access should be time limited Edit users when the option is enabled the person using the service code can add edit and remove users Arm Dis Clr Bps when the option is enabled the person using the service code can arm and disarm the system clear alarms and bypass zones inhibit or isolate 6 22 2 Defining the service access time The function is available when the PERMANENT ACCESS option is disabled see Defining the service access rules Enter the user menu and press in turn O Ero The number of remaining hours will be displayed during which the access to the alarm system is still possibl
43. ition arming mode and outputs The timer compares the time with the control panel clock and executes the selected function at the preset time The installer defines which outputs will be controlled by the timers 1 Enter the user menu and press in turn Emre Baer ID The programming is effected by using the step by step method hence the programming step number will be presented on the and r LEDs of the first and second partitions see page 15 Table 2 Step 1 Selecting timer to be programmed Press in turn the suitable keys to select a timer 1 timer 1 Banc timer 2 timer 3 timer 4 3 Step 2 Selecting parameters to be programmed Press in turn the suitable keys to select a parameter 1 _ weekly schedule Pac D exception 1 Suef D exception 2 ni 4 D exception 3 Sia D exception 4 Emre D partition 1 arming mode Zears D partition 2 arming mode Irrespective of the selected parameter pressing the k w key in a subsequent step will take you back to Step 2 6 16 1 Programming the weekly schedule 1 Step 3 Programming timer activation deactivation time on Monday Use the and keys to move the cursor If you want you can only program the activation or deactivation time Instead of the other parameter enter the sequence 9999 then Press to go on to the next step 2 Step 4
44. me e g VERSA LCD GR green display and keys backlight VERSA LCDM WH white display and keys backlight 6 1 Keypads description 6 1 1 LEDs presenting partition and system state LED Color Description lt gt green indicates the partition state each partition has its own LED ON partition is armed blinking exit delay countdown is running in partition rp red indicates alarm or alarm memory in the partition each partition has its L own LED The way of presenting the information is shown graphically below The information is presented for 2 seconds and repeated _ LED is OFF l LED is ON The higher position in the list means the higher priority of the presented status EM MMM fire alarm Saas burglary alarm M M M M warning alarm EEEE tamper alarm M fire alarm memory EEEE burglary alarm memory M M warning alarm memory Em tamper alarm memory A yellow blinking when the system requires user s attention e g because of L a trouble or trouble memory The LED goes off if one or both partitions are armed a blue indicates the service mode ON the service menu is available on the keypad blinking the service menu is not available on the keypad it is either available on another keypad or has been hidden by the installer Information about the armed state can be extinguished after a time period defined by the installer Entering
45. ming The installer should see to it that the user is effectively notified about the denial of arming the system 36 VERSA IP SATEL 7 1 1 Forced arming 1 After an attempt to arm the system from the keyfob has failed approach the keyfob enter the code and press 2 A message will appear on the display indicating why the arming has been denied If the message includes the 1 Ok phrase you can press the 1 key to force the arming 3 Press again the keyfob button to which the arming function is assigned Information on the forced arming is written into the event log 7 2 Failure of the arming procedure initiated from keyfob The information given below is not applicable if the keyfob button controls arming zone The installer can configure the alarm system in such a manner that it will not become armed if at the moment the exit delay countdown ends e there is a violated zone in partition which was not violated when the arming procedure was started e there is a trouble which did not exist when the arming procedure was started The installer should see to it that the user is effectively notified of the failure of procedure to arm the system initiated from the keyfob In the event of forced arming the control panel will ignore violations and troubles that occur after the start of the arming procedure 8 Operating the alarm system by telephone You can operate the alarm system by using a touch tone DTMF telephone
46. mity Card reader eee eee aaa 9 6 1 5 SOUNnd SIGNAIRG PEE E RA PE W da Poda ES Ao 9 6 2 C deS ant e adi ad Eta A ALE nA OLE da i ET 10 6 2 1 Factory default COdeS es media Od EEA E A Goa yada Ewy 11 6 3 PIMOT NK AG Roe ROAR a BEE 11 6 3 1 Arming without partition selection eee oss 11 6 3 2 Arming with proximity card WERTNK EDYANU u uuu aaancaa 11 6 3 3 Arming the selected partition uueuu eee aaa aaa aaa 11 6 3 4 QuiclearMiNg ii a tO AA doe that ed een i Raat SLE 12 6 3 5 Arming without delay 4 2 sass s O A RE AAAA AAAA AEP AAAA PAROS 12 6 3 6 Information about bypassed ZONES eeeu ue aaa aaa aaa aaa 12 6 3 7 Denial of arming and forced arming eee esse ua aaa aaa aaa aaa aanita 12 6 3 8 Failure of arming procedure aricii w a A WA AW O AO A ES een 13 6 4 Disarming and alarm learing sasiad l AGA dy abe o EEE Jaka 13 6 4 1 Disarming and alarm clearing without partition selection eeeee aaa aaa aaa 13 6 4 2 Disarming and alarm clearing with a proximity card MWERYMKOPYEANU 13 6 4 3 Disarming and alarm clearing in selected partition ee eee aaa aaa aaa 14 6 4 4 Viewing the zones which triggered alarm ee eee aaa aaa aaa aaa aanita 14 6 5 Quick inspection of partition status eeeee eee aaa aaa aaa aaa aaa aaa aaa aaa Ennen nanen Ennn 14
47. nhibit the zone or to cancel inhibiting the zone The system can be armed after eliminating the cause of the zone violation or after bypassing the zone Violated zones 1 Ok 2 Check an alarm zone outside of the exit route is violated You can press the w key to cancel the arming press the 1 key to force the arming press the key to check which zone is violated If two or more such zones are violated the indicator will be flashing on the display To scroll through the list of violated zones use the and x 4 keys If you have the ZONE INHIBITION permission you will be able inhibit the violated zone by pressing Au A message will be displayed prompting you to confirm the command to inhibit the zone press to inhibit the zone or to cancel inhibiting the zone Troubles 1 Ok 2 Check there is a trouble in the system You can press the w key to cancel the arming press the 1 key to force the arming press the key to view the trouble log the 7 SYSTEM STATE function will start see Checking the troubles system state p 30 Information on the forced arming is written into the event log 6 3 8 Failure of arming procedure The installer can configure the alarm system in such a manner that it will not be armed if at the moment of completing the exit delay countdown e there is a violated zone in partition which was not violated when the arming procedure was
48. o operate the alarm system by means of a proximity card reader INT CR and INT IT proximity card arm disarm devices are provided with the reader Reporting reporting events that occurred in the alarm system to the monitoring station The information about occurrence of an event can be transmitted via telephone line Ethernet network etc The companies offering the alarm system monitoring service undertake to intervene if specific events occur e g alarms troubles etc Service code a code that allows access to the service mode as well as some functions in the user menu Service technician the person whose function is to control operability of the installed alarm system and its components as well as to eliminate possible problems These duties can be fulfilled by the installer or a person assigned by him Siren beacon a device providing information about alarms or other events in the alarm system by means of acoustic or optical signaling Tamper alarm reaction of the alarm system to opening the housing of a device which is part of the alarm system tearing off the device from the wall cutting through the alarm system cables etc Actions taken by the alarm system may be similar as in the event of alarm however if the tamper alarm occurs it is advisable to call in the installer so that he can make a checkup User a person which can operate the alarm system using a code proximity card or remote control keyfob
49. r for the purpose of communication via the SATEL server ID 6 21 8 Checking the current supply voltage in modules Ka Not all modules provide information on the current voltage Enter the user menu and press in turn Gwxuz Awxuz D Information on supply voltage of the lowest address module will be displayed To scroll through the list use the arrow keys 6 21 9 Outputs reset Use the function to e deactivate 5 DURESS ALARM 14 CHIME or 15 CONTROLLED function outputs if the cut off time equal to O is programmed by the installer for such an output the output can only be deactivated in this manner SATEL VERSA IP 33 e deactivate for 16 seconds the 11 FIRE DETECTORS POWER SUPPLY function output to clear the alarm memory of fire detectors e activate the 21 DETECTORS RESETTING function output Enter the user menu and press in turn Swxuz D D 6 22 Service The functions related to control panel programming starting local or remote programming are described in the PROGRAMMING manual 6 22 1 Defining the service access rules Enter the user menu and press in turn U 5m In the upper line of the display the function name will be presented and in the lower one the first of the available options You can scroll through the list using the and keys The following symbol is situated in the upper right corner of the display ki option is enabled option is d
50. r the last keypress Use the and keys to move the cursor The key clears the character to the left of the cursor 4 Press to confirm the entered number Characters available after next keystroke mode ABC mode abc OO NIOJOO R WIN lt OO FNIOJOR WIN lt Table 4 Characters available in the keypad when entering telephone numbers to change the letter case press key Special character _ Function description switch over to pulse dialing switch over to tone dialing DTMF waiting for additional signal 3 second pause 10 second pause signal x in DTMF mode signal in DTMF mode other signals generated in DTMF mode Q2Q0o0o0 F Tnm Ow Table 5 Special character functions 6 18 Programming codes to acknowledge clear messaging 1 Enter the user menu and press in turn Bmno S D 2 Press in turn the suitable keys to select the telephone number for which the code to acknowledge clear voice messaging is to be defined the phone numbers to which voice messaging is not enabled are only available to the installer 1 _J telephone 1 P abc 0 telephone 2 Jder HD telephone 3 ni 4 D telephone 4 Sm 44 ID telephone 5 30 VERSA IP SATEL Emre ID telephone 6 Zears D telephone 7 Buv D telephone
51. r to obtain information on the zone types and output functions 9 Step 5d Assigning function to 433 MHz keyfob button 2 Proceed in the same way as in Step 5c 10 Step 5e Assigning function to 433 MHz keyfob button 3 Proceed in the same way as in Step 5c 11 Step 5f Assigning function to 433 MHz keyfob button 4 Proceed in the same way as in Step 5c 12 Step 5g Assigning function to 433 MHz keyfob button 5 two buttons pressed simultaneously see Operating the alarm system by means of keyfob p 33 Proceed in the same way as in Step 5c 22 VERSA IP SATEL 13 Step 5h Assigning function to 433 MHz keyfob button 6 two buttons pressed simultaneously see Operating the alarm system by means of keyfob p 33 Proceed in the same way as in Step 5c Pressing the w key between Step 5a and Step 5h will cancel the keyfob adding but will not terminate the user adding procedure 14 Step 6 Adding APT 100 keyfob If the ABAX wireless system controller is connected to the control panel the bidirectional APT 100 keyfob can be assigned to the user Press in turn 1__ and I if a keyfob is to be assigned to the user or only if no keyfob is to be assigned to the user 15 Step 6a Selecting APT 100 keyfob addition method Press if the keyfob serial number is to be entered or press in turn A if the serial number is to be read by the ABAX wireless system controller during transmission 16 Step 6b Adding APT
52. ress the 1 key to proceed with the arming press the oni key to start the INHIBIT function see Zone inhibiting p 25 Bypassed zones 1 Arm if you don t have the ZONE INHIBITION right You can press the W key to cancel the arming press the a key to proceed with the arming 6 3 7 Denial of arming and forced arming The installer can configure the control panel so that initiating the arming procedure is impossible if e in the partition to be armed at least one zone that must not be violated during arming the PRIORITY option has been enabled for the zone by the installer is violated e in the partition to be armed at least one alarm zone is violated beyond the exit route e there is trouble in the system If you have the INSPECTION right you will be informed about the cause of refusal to arm the system the order of message descriptions corresponds to their priority Zone zone number violat a zone with enabled PRIORITY option is violated If two or more such zones are violated the l indicator will be flashing on the display To scroll through the list of violated zones use the and keys You can press the k w key to cancel the arming SATEL VERSA IP 13 press the 4ani aoni key to inhibit the violated zone you must have the ZONE INHIBITION right A message will be displayed prompting you to confirm the command to inhibit the zone press to i
53. rting the arming procedure which is equivalent to arming if the exit delay has not been programmed 2 tones disarming 4 tones alarm clearing 7 tones arming is not possible or the arming procedure has failed Tone duration is approx 0 3 seconds Fig 3 APT 100 keyfob gray enclosure A numeration of LEDs B numeration of keyfob buttons button 6 pressing buttons 1 and 5 simultaneously SATEL VERSA IP 35 Fig 4 T 4 keyfob 433 MHz keyfob A numeration of keyfob buttons button 5 pressing buttons 1 and 2 simultaneously button 6 pressing buttons 1 and 3 simultaneously Fig 5 MPT 300 keyfob 433 MHz keyfob black enclosure A numeration of keyfob buttons button 5 pressing buttons 1 and 2 simultaneously 7 1 Denial of arming 1 The information given below is not applicable if the keyfob button controls arming zone The installer can program the control panel so that arming by means of keyfob is not possible when e in the partition to be armed at least one zone that must not be violated during arming the PRIORITY option has been enabled for the zone by the installer is violated e in the partition to be armed at least one alarm zone is violated beyond the exit route e there is trouble in the system e there is low battery in the keyfob In such a situation to arm the system you must either eliminate the cause that prevents arming or force the ar
54. s Zone bypassing reduces the level of protection When bypassed the zone may enable the intruder to get inside the protected area despite the system being armed If a zone is bypassed because of its malfunctioning call in the service technician immediately to repair the defect For security considerations the installer may reduce the number of zones that the user will be allowed to bypass The zone bypassing functions can also be used to unbypass the zones the zone inhibiting function makes it also possible to unbypass an isolated zone while the zone isolating function makes it also possible to unbypass an inhibited zone 6 12 1 Zone inhibiting The inhibited zone will remain bypassed until disarming the partition it belongs to or until unbypassing the zone by the user If the zone belongs to two partitions and is only armed when both partitions are armed it will be unbypassed after disarming one of the partitions Enter the user menu and press in turn aani 1 J G Shown in the upper line of the display will be a message to inform you that the zone is bypassed and in the lower line the zone name You can scroll through the zone list using the and keys There is a symbol in the upper right corner of the display zone is not bypassed zone is inhibited 26 VERSA IP SATEL iii zone is isolated Press any number key to change the displayed symbol to one of the following symbols Li th
55. se the and keys If the GRADE 2 option is enabled two functions for viewing the events are available for the installer in the user menu Bm G 1 G all events saved to the control panel memory will be displayed Sia G Pac events required by the EN 50131 Standard for Grade 2 will be displayed 6 14 Auto arming deferment Partition can be armed automatically by the timer on specific days at specific time If the installer defines the time by which the auto arming is to be deferred you can defer the arming 6 14 1 Simple auto arming deferment The installer defines whether the users will be allowed to use the simple auto arming deferment and whether they will be able to use the simple auto arming deferment just once or multiple times The simple auto arming deferment is possible during the auto arming delay countdown The keypad displays then a suitable message and can additionally emit a sound signal Press the key twice to defer the auto arming SATEL VERSA IP 27 6 14 2 Auto arming deferment by means of function Enter the user menu and press in turn Gmno 1_ 0 6 15 Setting the system time and date Enter the user menu and press in turn ED The currently programmed time will be displayed Enter a new time and then press U The date will be displayed Enter the new date and then press HUD 6 16 Programming the timers You can program 4 timers The timers can control part
56. some zones in the partition are armed as selected by the installer The installer should indicate the zones to be armed when a user stays in the protected area but there is no risk of the zones being violated by the user during the daytime If no such zones are indicated by the installer the user will not be able to arm the partition in this mode Detector the basic component of alarm system which analyzes the environment and if a situation recognized as a threat occurs transmits appropriate information to the control panel e g motion detectors on registering motion magnetic contacts on opening the door window glass break detectors on breaking glass pane gas detectors on sensing gas etc Entry delay time counted from the moment of entry into the protected area which makes it possible to disarm the partition before the alarm is triggered Entry route the route which the user must have to follow after entry into the protected area before being able to disarm the system It is usually the same as the exit route Exit delay time counted from the moment of starting the arming procedure in the partition which makes it possible to leave the protected area before the alarm is triggered Exit route the route which the user must have to take after arming before he leaves the protected area It is usually the same as the entry route Fire alarm alarm triggered by fire detectors or from the keypad in the event of fire
57. started e there is a trouble which did not exist when the arming procedure was started If the arming has been forced the control panel will ignore violations and troubles which took place after starting the arming procedure 6 4 Disarming and alarm clearing Disarming and alarm clearing are carried out in the same way the procedures being interconnected If the partition is armed and an alarm is triggered in it then disarming will also mean alarm clearing 6 4 1 Disarming and alarm clearing without partition selection Enter the code and then press the key Disarming alarm clearing will take place in the partitions to which you have access 6 4 2 Disarming and alarm clearing with a proximity card assy ee a AE 1 Press any key on the VERSA LCDM WRL keypad to activate it In order to clear the alarm without disarming the partition arm again the partition in the same mode see Arming p 11 14 VERSA IP SATEL 2 Bring the card close to the keys and move it away Disarming alarm clearing will take place in the partitions to which you have access The reader in VERSA LCDM WRL keypad is enabled for 5 seconds after activating the keypad 6 4 3 Disarming and alarm clearing in selected partition 1 Indicate partition which is to be disarmed and or where alarm is to be cleared press one of the keys EE partition 1 partition 2 2 Press the key Backlight of the keys will start blinking which indicates that
58. submenu just press the key with number corresponding to the submenu number In order to start a function press the key with number corresponding to the function number and then FD You can quickly start the selected function by entering at once a sequence of some digits corresponding to the consecutive submenu numbers and the function number and pressing For example to start the zone inhibiting function enter the user menu and then press EZ HHD where entering the 4 BYPASSES submenu A 40 running the 1 INHIBIT function Remember that the sequence of digits which starts a function e g from the main menu level will not start the same function from the submenu level 6 8 2 Step by step programming method LED status Number of gt 1 rb Bu rb programming step so ojo uoja A w p Table 1 The manner of indicating the programming step __ LED OFF I LED ON In case of some functions e g adding and editing users configuring timers etc the programming is effected by using the step by step method After calling the function and 16 VERSA IP SATEL selecting the item to be configured from the list the first parameter available for programming will be displayed After pressing HD you will go on to programming another parameter if you have entered some changes they will be saved Af
59. t lt N Sloan Nena ok VE IE E EJE JE Bere E 2FCJSSEELIL FG Table 2 Characters available when entering names The upper case letters are available under the same keys to change the letter case press E3 v I ig I 6 8 4 User functions list Shown in square brackets are key sequences that enable calling the given submenu or starting the given function from the main menu level The functions that are only available after entering the service code have been specially highlighted white text against black background The access to other functions depends on the user rights Highlighted with SATEL VERSA IP 17 a frame are the functions which are available or change the operating mode if the GRADE 2 option has been enabled by the installer 14 1 Change code changing own code 2 2 Users 214 1 New user adding new user 22 2 Edit user editing user 23 3 Remove user removing user 3 3 Abort v msg canceling telephone messaging 4 4 Bypasses 41 1 Inhibit inhibiting zones 42 2 Isolate isolating zones 5 5 Event log viewing events 5 1 viewing all events 5 2 viewing events required for Grade 2 6 6 Settings 61 1 A arm defer auto arming deferment 62 2 RTC clock programming the clock 63 3 Timers programming the timers 64 4 Tel numbers programming telephone numbers to be notified 65 5 Msg clr codes programming codes to acknowledge
60. ter all parameters have been configured you will either return to the selection list or exit the user menu depending on the function The and r LEDs of the first and second partition show the number of programming step see table 1 Some programming steps may be sometimes not available 6 8 3 Entering data The changes entered will be saved after pressing the key Use the wj key to quit the function without saving changes Entering digits To enter digits use the numeric keys Entering hexadecimal characters To enter digits use the numeric keys and to enter characters from A to F use the and keys keep pressing the key until the required character appears Entering names The characters that can be entered by using the keys are presented in Table 2 Keep pressing the key until the required character appears Long press the key to display the digit assigned to it Shown on the left side in the upper line of the display is information about the letter case Abc ABC or abc it will be displayed after pressing any key and will be visible for a few seconds after the last keystroke The key moves the cursor to the right and the key to the left The key deletes the character on the left side of the cursor Characters available after next keystroke pei tite si a ii iti fel 1 O mn O O0 RIWI N O gZ o 3 a a x eclo 5 x 5 o 5o u l
61. the code and pressing the w key will display again the armed state information If the GRADE 2 global option is enabled by installer the PB LEDs indicate alarms only after entering the code and pressing the wj key blinking of the TA LED means that there is a trouble in the system some zones are bypassed or that there was an alarm When programming by means of the step by step method the and r LEDs present the number of the current step see p 15 When you are using the user menu or service menu the A LED is e blinking rapidly during navigation through the menus and submenus 8 VERSA IP SATEL e steady on after a function is started 6 1 2 Display The display provides a number of data facilitating communication between the alarm system and the user The installer defines how the display will be backlit and selects the information to be shown on the display screen The display can work in normal mode or in zone presentation mode the modes being toggled by means of the key When in the normal mode the date and time in installer defined format or the keypad name are presented in the upper line of the display In the zone presentation mode symbols are displayed showing the status of zones available in the system where the control panel settings do not provide for detector presence at a zone the status of the zone is not displayed The numbers around the display correspond to the zone numbers
62. the manual test transmission eeuee eee ea teeter ee ee aaa 32 6 21 5 Telephone reporting test c cec ct lec esata LO A o O O GOA en rtnn e et 32 6 21 6 Checking the firmware version of control panel eeesu eee aaa aaa aaa 32 6 21 7 Checking the firmware version of modules see eee eee aaa aaa aaa aaa 32 6 21 8 Checking the current supply voltage in modules eeuuuueee aaa aaa aaa aaa aaa 32 6 21 9 Quiputs reset a i AA A EA AAAA A E O PoE T A ERP ALLEE 32 6 22 SONICS zai A Aa abo dal ah EEEE E a EFA oi Kd JE taa 33 6 22 1 Defining the service access rules eeeu ue a aaa aaa aaa 33 6 22 2 Defining the service access time oueee aaa aaa aaa aaa aaa aaa 33 7 Operating the alarm system by means of keyfob sssasaaaaaaaaaaaaaaaaaaaaaaaanaaaa 33 7 1 Denialaraminq zawali LO A wia i zbada 35 7 1 1 Forced arigera casters tech zad Et c a a COW atak edt st ka 36 7 2 Failure of the arming procedure initiated from keyfOD cece ee eeeeeneeeeeeeeeeeeeeeneeeeeeeeeeees 36 8 Operating the alarm system by telephone cccccccceseeeeeeeeeeeeeeeeeeeeeeeeeeceeeeeeeeeeeneees 36 8 1 Starting the operating by telephone 2 cc ceeeeeceeccee tenes deeeceeeeeeeeeseneeseneeseteeseeeeesedeeseeenens 36 8 2 Voice MENU a aiw A A EEE A speeded pica A PK IE 37 8 3 Ending the operating by telephon
63. to a new user Baer and ID in turn if you want to remove a keyfob R Removal of the keyfob does not erase its settings functions assigned to the keyfob The installer can remove all the 433 MHz keyfobs and their settings by using the REM RX Kk FOBS function SERVICE MODE 2 HARDWARE 0 1 KPDS amp EXPS gt 9 REM RX K FOBS 7 Step 6 Editing APT 100 keyfob Press HUD if you want to move on to the next step 1 and in turn if you want to add a keyfob the procedure is similar to that for adding the APT 100 keyfob to a new user however if the user had a keyfob before the control panel when assigning functions to the buttons and defining the rules of confirmation will suggest the same settings as for the removed keyfob Pac and I in turn if the user has a keyfob and you want to edit functions assigned to the keyfob buttons the procedure is similar to that for assigning functions after an APT 100 keyfob has been added to a new user Baer and ID in turn if you want to remove a keyfob Removal of the keyfob does not erase its settings functions assigned to the keyfob and rules of confirmation The installer can remove all the APT 100 keyfobs and their settings by using the REM ABAX KFBS function SERVICE MODE 2 HARDWARE 1 KPDS amp EXPS 08 REM ABAX KFBS 4oni and ID in turn if the user has a keyfob and you want to edit th
64. uble memory 1 Yes prompt will be displayed 2 Press ES to clear the trouble memory pressing another key will cancel clearing the trouble memory If the SERVICE MESSAGE AFTER TAMPER ALARM option is enabled in the control panel only the installer can clear the tamper alarm memory 6 20 Output control Using the keypad you can control the operation of devices connected to the outputs e g to raise lower roller blinds shutters turn on off lighting or heating etc The installer defines how the outputs should work whether the output will be activated for a defined time or it will remain active until deactivated by the user timer etc 6 20 1 Quick control of outputs The installer can assign outputs to the numeric keys and allow them to be quickly controlled without entering the code SATEL VERSA IP 31 Quick activation of output Press the key to which the controllable output is assigned and then HD Quick deactivation of output Press the key to which the controllable output is assigned and then k w 6 20 2 Controlling the outputs by means of function Enter the user menu and press in turn D The output number is shown in the upper line of the display and the output name in the lower line You can scroll through the list of outputs by using the E3 V and A keys Information on the output state is shown in the upper right corner of the display ik output is activated output is deactivated
65. uto arming delay 2 short beeps every seconds countdown of entry delay 2 short beeps every 3 seconds signaling a new trouble Short beep every 0 5 seconds warning alarm Continuous beep alarm Long beep every second fire alarm 6 2 Codes Operating the alarm system by means of the keypad is possible after entering the code Only some functions can be run without the code being entered Do not make your code available to other people Using an incorrect code three times may trigger an alarm block the keypad for 90 seconds SATEL VERSA IP 11 6 2 1 Factory default codes By default the following codes are preprogrammed in the control panel user 30 code 1111 service code 12345 A 6 3 Arming The factory default codes should be changed before you start using your alarm system see Change own code Completion of the steps below will start the arming procedure The procedure ends when the exit delay time elapses if the countdown is completed successfully the system becomes armed see also Failure of arming procedure p 13 If the exit delay time is O the system becomes armed instantly You can change the arming mode which means you do not have to disarm the system to set the partition to another arming mode In the case of alarm changing the arming mode or re activating the same arming mode will result in clearing the alarm it does not apply to the quick arming mode

Download Pdf Manuals

image

Related Search

Related Contents

Moca Owner`s Book  の環境&リサイクリング機械シリーズ  Configuration Manual, d41 Ascom DECT Handset, TD 92641GB  AMP CS2 取扱説明書  PTB330 取扱説明書  Precision Hydrogen Generator user manual  2 - 日立の家電品  Equip 10" patch panel Cat.5e, 12-port  Mode d`emploi DPC pour programme 25351400006  Minicom Advanced Systems Switches User's Manual  