Home
Manuel DOSIPOOL-ANG-4052-mars 2010
Contents
1. Select ALARM Select ON with the T I keys and confirm by pressing OK The visual alarms are still activated SS 4 Professional menu and options Your professional is able to obtain access to the menu dedicated for his use This menu contains advanced functionalities which will enable him to optimise the performance of your device Moreover your professional can set the available options for you a Chlorine probe option Thanks to its revolutionary technology the chlorine probe ref OPTO9POO0003 measures directly the free chlorine contained in your pool With this option your device becomes fully automatic This function can be installed later 11 b Automatic cover function This option OPT04P000001 allows the device to be connected to the automatic cover It allows the injection of disinfectant to be adapted automatically depending on the position of the automatic cover or a switch This function is available only in dosing mode chlorine option deactivated or manual mode c Separate flow sensor The flow sensor ref OPTO3POO0002 can detect the presence of a flow in the pipes Detection of no flow in the pipes will immediately stop the injection of disinfectant d Empty container sensor The empty container sensor automatically detects a lack of pH corrector product in the container VI ALARMS v Whenever an alarm is tripped a message appears on screen to specify the alarm type It is accompanied by
2. on the pH probe has been removed Check that the pH probe is operating correctly Check the injection and suction valves 12 ALARMS CAUSES SOLUTIONS Cl REGULATION The device has detected that the most recent attempts to maintain the chlorine level around the chlorine set point value have been unsuccessful Chlorine REGULATION is suspended Check that the liquid chlorine container is not empty Check that the disinfectant pump is injecting correctly Check the injection and suction valves EMPTY CONTAINER option Detects that the pH corrector container is empty when the Empty container option is installed pH REGULATION is suspended Replace the pH corrector container taking the necessary safety precautions pH STOP No calibration of the pH probe has been validated pH REGULATION is suspended Calibrate the pH probe FILTRATION LOW The device has detected a filtration time far less than the recommended filtration time No function is suspended Increase the filtration time FLOW option Detects a lack of sufficient flow in the pipes when the Flow option is installed Disinfectant injection and pH REGULATION are suspended Check the entire hydraulic circuit of the filtration unit If despite the checks the problem persists contact your professional The device is provided with a protected diagnostic aid menu reserved for professionals It enables them to
3. provided by a third party for installation of the equipment 2 Damage caused by nonconforming installation 3 Problems caused by an alteration accident mistreatment negligence of the professional or the end user unauthorised repairs fire floods lightening frost armed conflict or any other case of force majeure ATTENTION The warranty does not cover any equipment damaged due to failure to comply with the safety installation operation and maintenance instructions set out in the present manual Every year we improve our products and software These new versions are compatible with the prior models New hardware and software versions cannot be covered by the warranty on the previous models 5 Application of the warranty y For more information on the current warranty get in touch with a professional or our After Sales Service Department All requests should be accompanied by a copy of proof of purchase v When you buy your equipment don t hesitate to activate your warranty online on http www pool technologie fr This will enable you to receive any new information that could be of interest to you Y No part will be replaced unless the defective part has been returned beforehand Any part which is not returned will be charged based on the current price list 6 Laws and disputes yY The present warranty is subject to French law and all other European directives or international treaties which are in force at the time of the c
4. PERATION A Never use hydrochloric acid Use only a pH corrector product acid or base which is recommended by your professional The use of any other chemical product could cause irreversible damage to the device Where pH corrector product is added directly to the pool it is essential to distribute it regularly around the delivery orifice In the case of an installation with chlorine option the chlorine option goes to safety configuration upon detection of a pH lt 6 0 It is reactivated automatically as soon as the pH rises to a value gt 6 again A It is IMPERATIVE to check the levels of chlorine and pH each week with your usual analysis kit An excessive chlorine level and or a low pH tends to cause oxidation on all metallic parts and can lead to irreversible deterioration of the pool lining automatic cover pins and slats telescopic shelters and heat exchangers If you cover the pool shelter tarpaulin cover ventilate the pool regularly to prevent dissolved gases accumulating since these could disturb the measurements of the pH or chlorine probes The manufacturer may not be held liable in the event of failure to comply with these operating instructions A BASIC FUNCTIONS 1 Start Stop To stop or restart a function v Press key C for 3 seconds Your device allows you to carry out various operations detailed below Key C also allows you to stop an operation in progress and return to the main menu 2 Parameters displaye
5. USER MANUAL AUTOMATIC DOSING REGULATION DISINFECTANT PH FAMILY POOLS UP TO 160 m ce x Ref PAPI004052 GB REV 03 10 TABLE OF CONTENTS I SAFETY INSTRUCTIONS IL PACKING LIST TIL INSTALLATION IV ACTIVATION V CHLORINE PROBE OPTION VI OPERATION VI ALARMS VII WINTERING IX WARRANTY X PROTECTING THE ENVIRONMENT Pool Technologies declares this equipment complies with the following E U directives Electromagnetic Compatibility Directive 89 336 EEC modified 92 31 EEC and 93 68 EEC Low Voltage Directive 73 23 CEE modified 93 68 EEC Chief Executive ee ee Cran To improve product quality the manufacturer reserves the right to change the characteristics of its products at any time without prior notice I SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE ALL INSTRUCTIONS A In the manual this symbol indicates a WARNING It informs you of the risk of damage to the equipment or serious injury to humans It is very IMPORTANT that you pay attention to these warnings WARNING RISK OF ELECTRIC SHOCK The safety instructions outlined in this manual are not exhaustive They highlight the most common risks of using electrical equipment in the presence of water Any installation and use of this equipment should be carried out with caution and common sense To prevent injuries or accidents install the equipment out of reach of children Ensure that the installation complies with t
6. an audible alarm if the function is activated v Ifa problem is detected the function in question goes to STOP and returns to ON as soon as the fault disappears ALARMS CAUSES SOLUTIONS LACK OF WATER The device has detected a lack of water in the pipes NO FLOW Disinfectant injection and pH regulation are suspended Check the entire hydraulic circuit of the filtration unit and the water level in the pool LOW WATER TEMP The device has detected a water temperature lt 10 C Disinfectant injection is suspended Disinfection is not necessary at a low water temperature pH LOW The device has detected a pH 0 5 points lower than the set point value pH regulation is suspended Check the pH value in the pool If the pH is low add pH base corrector directly in the pool at the discharge nozzles If the pH is normal calibrate the pH probe pH HIGH The device has detected a pH 0 5 points higher than the set point value pH regulation is not suspended Check the pH value in the pool If the pH is high add pH acid corrector directly in the pool at the discharge nozzles If the pH is normal calibrate the pH probe pH REGULATION The device has detected that the most recent attempts to correct the pH around the set point value have been unsuccessful pH REGULATION is suspended Check that the pH corrector container is not empty Check that the pH pump is injecting correctly Check that the rubber protection
7. ctant effect of the chlorine produced by the device To bring down the level of stabiliser in your pool follow the recommendations of your professional v Where chlorine is used the free chlorine level of the pool should be greater than or equal to 1 ppm A Do not use stabilising agent in the case of an installation with a chlorine probe A setor using any pool caulking product remove the pH probe from the accessories holder A Preferably use water from the public water supply Avoid using any water from natural sources rain runoff water reservoirs wells If you do use water from a natural source have it analysed beforehand and ensure that it complies with drinking water standards and if necessary carry out appropriate treatment yY The pH probe has been calibrated in the factory so it does not have to be calibrated again when the device is started for the first time Calibration of the pH probe should then be done on a yearly basis at the start of the swimming season Refer to the relevant section v To optimise the operation of your system we advise you to enter the pool volume in the parameters Refer to the relevant section v Adjust the dose of disinfectant product in accordance with the instructions in Section VI Your equipment is now operational Don t hesitate to activate your warranty online on http www pool technologie fr This will enable you to receive any new information that could be of interest to you V O
8. d Depending on whether or not the chlorine option is activated the main screen displays the dose of disinfectant set in the parameters and the pH value measured by the device in the pool or the free chlorine level and the pH value measured by the device in the pool DOS 10ml h a N 0 8ppm pH 0 70 pH 7 0 Basic situation or with chlorine Situation with chlorine probe probe option deactivated option installed and activated v Press the lt gt keys or the direct access keys to scroll the following parameters j WATER TEMPERATURE Indicates the pool water temperature Indicates the recommended time to obtain optimum FILTRATION TIME treatment Comply with these indications v The main screen also shows the status of the functions STATUS CODE MEANING ON The function in question is on standby OFF The function in question has been deactivated STOP An alarm has placed the function in question in safety configuration INJ The pH pump injects the corrector product 3 Adjusting the disinfectant dose v Press t to adjust the hourly dose of disinfectant y Where chlorine is used maintain the free chlorine level in the pool at between 1 and 1 5 ppm B ADVANCED FUNCTIONS To obtain access to the advanced functions simply press the OK key for 5 seconds 1 Injection of a dose of disinfectant INJ DOSE Th
9. determine the cause of the problem on the spot For all assistance consult the FAQs on http www pool technologie fr If you do not find an answer to your problem post us your message via our website or contact your professional You can also contact our After Sales Service Department INDIGO No 0 892 705 520 from France 0 34 incl VAT min Please supply Y Proof of purchase v Serial number of the controller and the pH probe y Date when the device was installed v Name of the professional who sold and or installed the equipment v Salinity pH chlorine level water temperature stabiliser level pool volume daily filtration time 13 VII WINTERING A When the water temperature is less than 10 C the low water temperature alarm will be actuated and will automatically stop injection of the disinfectant Stop the device by pressing key C for 3 seconds When wintering the pool emptying the pool and or stopping filtration carry out the following maintenance operations v Remove the pH probe and store it in the rubber protector filled with drinking water v Rinse the entire pH corrector circuit with fresh water Changing the pump peristaltic pump tube Each season replace the peristaltic pump hose and the check valves The maintenance kit ref KITO2Z2MAINMTP contains all the parts necessary for annual maintenance operations VIII WARRANTY All our care and technical expertise has gone into makin
10. e the following message indicates whether the operation has succeeded or failed ADJUSTMENT SUCCESSFUL PROBE UNSTABLE CALIBRATE PROBE OK OK Press OK to store the adjustment in memory To return to the main screen press C several times In the event of failure or if despite the adjustment you observe a major difference between the pH value measured in the pool with your usual analysis kit and the value displayed by the device press OK and perform calibration of the pH probe as explained in the following section Calibration of the pH probe Each pH probe has its own characteristics To obtain satisfactory pH regulation it is recommended that the pH probe be calibrated at the start of the season and after any change to the pH probe KA AR ROR TR Take the pH7 and pH10 control solutions Remove the pH probe from the accessories holder and stop up with the 1 2 dia plug Press the OK key for 5 seconds and select PH PROBE confirm by pressing OK Select the CALIBRATION function with the lt keys and then confirm by pressing OK Scrupulously follow the instructions appearing on screen At the end of the procedure the following message indicates whether the operation has succeeded or failed CALIBRATION SUCCESSFUL PROBE UNSTABLE SEE MANUAL OK OK Press OK to store the calibration in memory To return to the main screen press C several times In the event of calibration failure start the procedure again In
11. ed colored pipe Comply with the direction of the arrows on the disinfectant pump cover Connect the outlet of the disinfectant pump to the injection connector with the remainder of the supplied colored tubing IV ACTIVATION A When installing the device for the first time or at the start of a new season it is imperative to check and correct the following points yY The pool water must be clear and free from algae and sediments v The water should be correctly balanced Alkalinity Total Hardness e Alkalinity is a measure of the level of bicarbonates dissolved in the water e Total Hardness is a measure of the water s hardness i e the level of calcium or magnesium salts dissolved in the water y The pH of the water should be stabilised between 7 0 and 7 2 A setor using any pool caulking product remove the pH probe from the accessories holder WARNING Whatever the system of chemical treatment the effectiveness of chlorine decreases very rapidly as the pH increases and scale precipitates more quickly when the pH level is high or unstable Effectiveness of chlorine Source French Ministry of Health v Filters and primary filters must be clean and used in accordance with the manufacturer s specifications v The level of stabilising agent should be less than 50 ppm The role of the stabilising agent or isocyanuric acid is to protect the chlorine from the effects of UV A level that is too high will impede the disinfe
12. f this instruction will lead to abnormal oxidation of the metallic parts which could result in a complete breakdown of the device v Assembly of the controller and its accessories must be performed strictly in compliance with the following layout diagram PH correcting agent CONTROLLER DESINFECTANT CONTAINER temperature flow sensor _ pH PROBE DESINFECTANT INJECTION FLOW OUT AGENT INJECTION chlorine probe FLOW IN In case of chlorine probe installation B INSTRUCTIONS 1 Controller v Choose a location that is easily accessible close to the filtration unit Install the controller vertically far enough away from the pool to comply with the regulatory distance in force in your country Use the mounting kit supplied Do not cover and allow air to circulate between the rear of the controller and the wall Any contact between the controller and the pool water may cause an electric shock The controller must be permanently connected to the filtration unit and servo controlled by the pump switch Do not use an extension cord Do not plug the device into an electric power outlet Turn off the differential circuit breaker beforehand Ensure that the controller switches off when the filtration pump stops 2 pH pump v v v SSS v Assemble the accessories holder after every other treatment cleaning or heating device Provide for a pipe of at least 200 mm without any elbo
13. g this device It has undergone quality control procedures If despite all the care and knowledge which has gone in to its manufacture you had to use our warranty free replacement only applies to parts of our equipment which are defective excluding transport Warranty period 2 YEARS for new equipment controller pH probe 1 YEAR for replacement probes 1 MONTH for After Sales Repair and spare parts Authentic invoice date 2 Scope of warranty The warranty applies to all parts except wear parts which must be replaced regularly The device is covered for any manufacturing fault only when it has been used normally in a family pool Use in public pools voids the warranty 3 After Sales Service v All repairs are done in our workshop All return transport costs are payable by the user No compensation will be paid for downtime and loss of enjoyment of the equipment when it is being repaired v In all cases the equipment is always transported at the cost and risks of the user Before accepting delivery it is up to the user to check that the equipment is in perfect condition and if necessary to state any reservations on the carrier s transport slip Confirm this to the carrier within 72 hours by registered letter with acknowledgement of receipt IMPORTANT A replacement under warranty will in no case extend the initial warranty 14 4 Limits of warranty The warranty does not cover 1 Equipment and labour
14. he regulations in force in the country of installation The filtration box power supply line should be protected by a differential circuit breaker with a tripping safety device of 30 mA maximum with a contact opening distance of at least 3 mm on all poles This device is completely different from the differential circuit breaker protecting the whole house which has a rating of about 300 to 500 mA In case of doubt get a qualified electrician to check your whole installation area installation Installation of this equipment should be performed by a qualified person in accordance with the electrical standards in force in the country of installation The power supply cables must be protected against accidental damage A damaged cable should be replaced immediately with an original cable exclusively Never cut or extend the cables It is important to turn off the power supply before carrying out any technical operation on the equipment Do not modify the device Any modification may damage the equipment or endanger human life Only qualified personnel should carry out maintenance or repairs in case of breakdown This device is intended for use in family pools only NON OBSERVANCE OF THESE INSTRUCTIONS MAY CAUSE DAMAGE TO THE DEVICE OR SERIOUS INJURY II PACKING LIST Before starting installation ensure the box contains KOK OK OX KK XX KK 1 User manual 1 Controller with mounting kit 1 Accessories holder provided wi
15. is function allows manual injection of a dose of disinfectant v Press the OK button for 5 seconds v Select the INJ DOSE function with the lt gt keys and confirm by pressing OK v You can change the injection time according to your needs with the t et keys Confirm by pressing OK v The countdown is started You can suspend or resume the countdown by pressing OK v At the end of the countdown the device automatically goes to regulation mode 2 Manual injection of pH INJ pH Manual injection of pH corrector product can be used to correct the pool pH level or to prime the pH pump when replacing the product container v Press the OK button for 5 seconds v v v v Select the INJ pH function with the lt gt keys and confirm by pressing OK You can change the injection time according to your needs with the f keys Confirm by pressing OK The countdown is started You can suspend or resume the countdown by pressing OK At the end of the countdown the device automatically goes to regulation mode 3 Adjusting the pH probe This function allows the device to display the pH value you have measured in your pool with your usual analysis kit v v v v 4 Select the Adjustment function in the pH PROBE menu with the lt keys then confirm by pressing OK Follow the instructions Select the value measured manually with the 1 l keys and confirm by pressing OK At the end of the procedur
16. laim and which are applicable in France Should any dispute arise concerning the interpretation or execution of the warranty sole jurisdiction is assigned to the Tribunal de Grande Instance High Court of Montpellier 15 IX PROTECTING THE ENVIRONMENT Protecting the environment is essential For our company this is a strong commitment Our products are designed and manufactured with materials and components which are of high quality environmentally friendly reusable and recyclable However the various parts of which they are formed may not be biodegradable European environmental directives set for each product category appropriate methods for managing and disposing of waste material The aim is to reduce and recycle wastes to prevent their components from becoming a danger and to encourage re use of the products The symbol mn stamped on a product means that selective collection is necessary and that it must be sorted from other household waste Therefore you must not discard our product by simply throwing it away anywhere You may deposit it in a waste collection centre Tf you buy a similar device you may leave the old one with your seller at the time of purchase Manufactured by POOL TECHNOLOGIE Zac des Jasses 115 rue de Il Oliveraie 34130 Valergues France www pool technologie fr 16
17. th a hydraulic grounding kit and 1 plug 1 2 1 pipe saddle dia 50 mm x 2 1 pH probe 2 buffer solutions pH7 and pH10 2 extra hoses pump peristaltic 2 Reducers 63 50 1 Water temperature low water sensor 1 pH kit comprising 5 m of semi rigid transparent tubing 1 suction strainer 1 injection connector dia 1 2 1 roll of Teflon Tape 1 Red disinfectant kit comprising 5 m of semi rigid colored tubing 1 suction strainer 1 injection connector dia 1 2 III INSTALLATION A INTRODUCTION A Before proceeding with installation of the device it is very important to check the following points Y Ensure that all of the hydraulic equipment is in good working order and is correctly sized In particular check the delivery of the filtration pump the capacity of the filter and the diameter of the pipes yY The device s treatment capacity should be appropriate for the volume of water to be treated and for the climate of the location in which it is installed A device which is designed to treat a volume of 100 m in a temperate climate should be limited to an 80 m family pool in a hot climate v The installation area should be dry and properly ventilated protected from rain splashes water spray and UV radiation Provide a location for each treatment product container which is a sufficient distance away from any electrical equipment Keep the containers separate from one another Non observation o
18. the event of a second failure call your professional You may need to replace your pH probe 10 A The calibration solutions are disposable They can be kept for 1 year in their sealed packet stored away from light and heat Throw away after use Never dry the pH probe with a cloth or absorbent paper since this could damage it Leave it to drip dry C OTHER ADVANCED FUNCTIONS 1 Annual reactivation For reactivation of the combined saltwater chlorinator pH regulator at the start of each season a number of operations described in Section IV must be performed However the Activation menu facilitates your task by guiding you step by step Press the OK button for 5 seconds S v Select the Activation menu with the lt keys and confirm by pressing OK v Use the arrows and the OK key to answer the questions asked v At the end of the procedure the following message indicates successful activation REACTIVATION OK PLACE FILTRATION ON AUTO OK Vv Press OK To return to the main screen press C several times 2 Choice of language This function allows you to have messages displayed in the language you have selected Vv Press the OK button for 5 seconds Y Select LANGUAGE v Select the desired language with the T l keys and confirm by pressing OK 3 Audible alarm By default the audible alarm is deactivated This function allows you to activate the audible alarm v Press the OK button for 5 seconds
19. w before and after the accessories holder to prevent any measurement disturbance Mount the accessories holder horizontally the arrow showing the direction of water flow must be visible on top Remove the rubber protection from the pH probe and then mount it on the accessories holder after taping it with 7 or 8 layers of Teflon Make sure it is not stuck in the pipe Mount the low water temperature detector on the accessories holder and tighten by hand Mount the injection connector on the accessories holder with Teflon Connect the suction strainer to the pH pump with part of the supplied pipe Comply with the direction of the arrows on the pH pump cover Connect the outlet of the pH pump to the injection connector with the remainder of the supplied tubing Connect the cable of the pH probe BNC plug to the base of the controller Keep it away from all other electric cables to avoid any electromagnetic disturbance which could distort the measurements Connect the cable of the low water and temperature detector to the base of the controller 3 Disinfectant pump v Position the pipe saddle at least 50 cm after the accessories holder Direct the opening preferably 1 2 downwards Mark then drill the pipe Mount the injection connector on the pipe saddle with Teflon The injection connector should be as close as possible to the water discharge into the pool Connect the suction strainer to the disinfectant pump with part of the suppli