Home

Manual

image

Contents

1. Cardinal DETECTO PZ3000 Series Ingredient Scale Owner s Manual pA REGISTERED 9001 CARDINAL SCALE MFG CO 8528 M372 O1 RevD PO BOX 151 e WEBB CITY MO 64870 Printed in USA PH 417 673 4631 e FAX 417 673 5001 01 10 www detectoscale com Technical Support Ph 866 254 8261 e techsupport cardet com INTRODUCTION We wish to thank you for your purchase of our TABLE OF CONTENTS SPECIFICATIONS 23000 Ingredient scale It has been designed NSTALLATION 3 and manufactured at our factory in Webb City MO U S A with quality and reliability POWER 4 Power 4 This manual will instruct you in the proper Battery 4 installation operation and maintenance of your new scale Please read it before attempting to SEN E DUE use the scale and keep it handy for future Battery Installation Replacement sow x xx wo 4 reference Extended Battery Operation 6 I OPTIONAL ZERO DEVICES 7 omi Statement KEYPAD DESCRIPTION 8 This equipment generates uses and can radiate radio frequency and if not ANNUNCIATORS 9 installed and used in accordance wilh the OPERATION 10 instruction manual may cause interference to MAINTENANCE 1
2. pound ounces with fraction kilograms pound ounces with decimal point and grams ZERO Pressing this key when the scale is on will zero the scale WOO G With the LITE WAY photo eye enable setup Photo i passing your hand over the photo eye sensor will cause the scale to zero Photo Eye 8528 M372 O1 Rev D e PZ3000 Series ANNUNCIATORS The annunciators are turned on to indicate that the display is in the mode corresponding to the annunciator label or that the status indicated by the label is active mnm The low battery annunciator is located in the upper left corner of the display It is used to indicate the battery status Refer to the Power Connection section of this manual for more details GROSS This annunciator is turned on to show that gross weight is displayed Gross weight will be displayed when no tare weight is stored b 4 STABLE This annunciator is turned on when the weight display is stable When off it means that the change in successive weight samples is greater than the motion limits selected during setup ZERO This annunciator is turned on to indicate that the weight displayed is within 1 4 division of the center of zero kg This annunciator is turned on to indicate the weight displayed is in kg kilograms POUNDS This annunciator is turned on to indicate the weight displayed is in pounds OUNCES This annunciator is turned on to indicate the weight displayed
3. WELDMENT 2 1 8528 D264 08 WEIGHBRIDGE 4 1 8528 B110 0A LOAD CELL ASSEMBLY DF 50T 9 2 6021 2003 FLAT HEAD SCREW 625 SOCKET HEAD 6 4 65401058 PAD 7 8528 B392 0A CABLE LOAD CELL 9 FT 8 6540 1004 RUBBER FEET STICK ON 6980 0004 STRAIN RELIEF 6610 3000 CONNECTOR PLUG 6021 2002 THUMB SCREW 10 32 X 3 4 8529 B045 08 LABEL REMOVE 593GR986 SERIAL TAG 6650 0087 STICKER MADE IN USA 6021 2001 CAP SCREW 10 32 X 1 SOCKET HEAD S S 6021 1258 SET SCREW 10 32 X 375 593R1021 LABEL NOTCH THIS SIDE 428H1079 LABEL PZ SCALE DECAL 6024 1484 FLAT WASHER 10 S S 20 8528 M372 O1 Rev D e PZ3000 Series PARTS IDENTIFICATION PZ3060 Base Assembly eer Zi 9 Pw N et tr e vm e mm NS RR C 0 n aJ e ae a auo u GN Zeg me M GREEN RED WHITE BLACK PIN 1 21 8528 M372 O1 Rev D e PZ3000 Series QTY PART NUMBER 1961 B006 08 14 4 15 10 16 4 17 4 18 7 20 1 21 0 2 6 23 2 25 1 22 PARTS IDENTIFICATION PZ3060 Base Assembly 1961 0002 08 1961 0004 08 1961 0005 08 2950 C121 4A 593GR986 6007 0009 6007 0011 6013 0045 6021 1013 6021 1429 6021 1454 6450 0001 6024 0037 6024 0040 6540 1058 6540 113
4. from you and place it face down on a table or bench 3 Referring to Figure No 2 locate the two screws on the angled edge of the indicator and remove the screws and washers under them NOTE The PZ3015 and PZ3030 use two thumbscrews and the PZ3060 uses two socket head cap screws 4 Referring to Figure No 6 remove the connector from the end of the battery holder and then remove the battery door and set it aside 5 Place the auxiliary battery door with fully recharged batteries on the indicator and then re connect the connector to the end of the battery holder See Figure No 6 6 Insuring no wires are between the battery door and the back of the indicator lower the battery door and install the two screws and washers removed in step 3 NOTE The PZ3015 and PZ3030 use thumbscrews and should be finger tightened only 7 Return the indicator to the scale wall or table stand The scale is ready for operation 8 Place the battery door removed in step 5 on a table or bench with the battery holder and battery strap up 6 8528 M372 O1 Rev D e PZ3000 Series POWER CONNECTION 9 Referring to Figure No 6 locate the battery charger jack on the battery door 10 Plug the AC power adapter battery charger into the jack on the battery door and then connect the AC power adapter battery charger into the proper electrical outlet 11 Allow approximately 4 to 8 hours to fully recharge the batteries Figure No 6 Battery Conn
5. in working with tools depend to a great extent upon the individual accuracy skill and caution For this reason the Seller is not able to guarantee the result of any procedure contained herein Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures Persons engaging the procedures do so entirely at their own risk Requirements Tare Capacity Certifications Weight Display 6 Digit 0 7 LCD Digital Display 7 5 W x 1 5 Dx 4 5 8 W x 8 D x 1 75 H 12 W x 12 D x 1 75 H 12 W x 12 D x 1 75 H 14 W x 12 D x 3 H Established on power up routine and maintained by auto zero circuitry 100 to 240 VAC 50 60Hz 12 VDC 1A wall plug in UL CSA listed AC power adapter Cardinal part number 6800 1045 OR optional 6 AA NiMH batteries 1 2v 2700 mAh NOTE On PZ3060 the batteries Cardinal part number 6800 0020 ARE included ZERO key on keypad Lite Way Sensor or optional Foot Switch or Piezo Button Operation 30 to 110 F 1 to 43 C Temperature Humidity 75 without condensation 1510 x 0 005 30lb x 0 01 60lb x 0 02 NOT LEGAL FOR TRADE 8528 M372 O1 Rev D e PZ3000 Series 1 Serial Number Date of Purchase Purchased Form RETAIN THIS INFORMATION FOR FUTURE USE PRECAUTIONS Before using this instrument read this manual and pay special attention to all WARNING symbols N IMPORTANT ELECTRICAL WARNING 8
6. input is above the range of the indicator UI L I IL L S m message indicates that the Contact your scale serviceman Hemove power and then reapply power If problem persists contact your scale serviceman This message indicates the display Inspect the scale cable and connector for is not receiving the signal from the damage If problem persists contact your scale base scale serviceman ort This message is displayed to indicate the scale is turning off 14 8528 M372 O1 Rev D e PZ3000 Series Remove the weight from the scale platform PARTS IDENTIFICATION Display Assembly ITEM PART NUMBER DESCRIPTION 1 593GR986 SERIAL TAG 2 4 6013 0039 NUT HEX 46 32 3 2 6021 0661 SCW PAN HEAD 46 32 X 25 X S S 6021 1032 THUMB SCRW 6 32 X 0 25 PZ3015 3015L amp 3030 6021 0300 SCW SOCKET HEAD CAP SCREW PZ3060 5 2 6610 2000 JACK SOCKET 7 4 6680 0045 SPACER PCB 46 X 250 8 2 6680 0052 WASHER LOCK 4 Z P 6980 0015 STRAIN RELIEF BUSHING SR 5N 4 BLACK 8528 B377 0A ZERO CABLE 11 1 8528 B378 0A LOAD CELL CABLE 8528 B379 0A DC POWER CABLE 13 8528 C365 0A BATTERY DOOR ASSEMBLY 14 8528 C366 0A ENCLOSURE WELDMENT 15 1 8528 D351 08 KEYPAD 16 1 8528 D359 0A PCB ASSEMBLY 8528 M372 O1 Rev D e PZ3000 Series 15 PARTS IDENTIFICATION Battery Door Assembly o SOLL 325 VY HAIN HO PON d TV39HVH
7. is in ounces 3 4 This annunciator is turned on to indicate the weight displayed is to the nearest 3 4 ounce 1 2 This annunciator is turned on to indicate the weight displayed is to the nearest 1 2 ounce 1 4 This annunciator is turned on to indicate the weight displayed is to the nearest 1 4 ounce 8528 M372 O1 Rev D e PZ3000 Series 9 OPERATION Press and hold approximately 2 seconds the ON OFF key until the scale is powered up With no weight on the scale press the ZERO key After a brief moment the display will show The scale is now zeroed and ready for use Place container on the scale the weight of the container will be displayed Press the ZERO key to return the scale to zero gt N gt Add your first ingredient to the desired weight re zero the scale for the second ingredient by pressing the ZERO key 8 Add the second ingredient to the desired weight and re zero the scale for the next ingredient by pressing the ZERO key 9 Continue adding ingredients in the same manner of operation 10 After completion remove the container and ingredients from the scale 11 Press the ZERO key to re zero the scale 12 You are now ready to begin again Instead of pressing the ZERO key you can zero the scale by passing your hand over the Lite Way photo eye if enabled or with the optional Foot Switch PZFS or the mountable Pushbutton PZPB Locking the Weighing Units If desired the weig
8. 0 ee pipa sigan eese 11 found to comply with the limits for a Class A computing device pursuant to Subpart J of Part TROUBLESHOOTING 13 15 of FCC rules which are designed to provide PARTS IDENTIFICATION 14 reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a SPECIFICATIONS residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference Dimensions Display You may find the booklet How to Identify and Resolve Scale Base Radio TV Interference Problems prepared by the PZ3015 Federal Communications Commission helpful It is PZ3015L available from the U S Government Printing Office Washington D C 20402 stock No 001 000 00315 4 PZ3030 PZ3060 All rights reserved Reproduction or use Zero without expressed written permission of editorial or pictorial content in any manner is prohibited No patent liability is assumed with Power respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease of application however success and safety
9. 0 6610 5007 6680 1091 8528 C381 08 8528 D367 1A 8540 B454 08 8528 B274 08 6610 3000 8528 B392 1A 428R1079 DESCRIPTION LABEL DETECTO BASE PLATE COMMODITY TRAY LOAD CELL TSP 100KG SERIAL TAG ASSEMBLY HEX HEAD BOLT 1 4 20 X 1 2 Z P BOLT HEX HEAD 1 4 20 X 1 Z P NUT HEX 1 4 20 WASHER LOCK 10 HELICAL SPLIT WASHER LOCK HELICAL 1 4 S S RUBBER PAD LEVELING FOOT CABLE CLIP INDICATOR MOUNTING BRACKET FRONT DISPLAY ASSEMBLY 1 4 20 SPACER X 1 2 O D X 1 HANDLE CONNECTOR PLUG 403 06 2042 CABLE LOAD CELL 9 FT PZ SCALE DECAL 8528 M372 O1 Rev D e PZ3000 Series NOTES 8528 M372 O1 Rev D e PZ3000 Series 23 STATEMENT OF LIMITED WARRANTY Detecto Scale warrants its equipment to be free from defects in material and workmanship as follows Detecto warrants to the original purchaser only that it will repair or replace any part of equipment which is defective in material or workmanship for a period of one 1 year from date of shipment Detecto shall be the sole judge of what constitutes a defect During the first ninety 90 days Detecto may choose to supply all necessary replacement parts and service during normal weekday working hours at no charge to the buyer After the first ninety 90 days Detecto will supply parts and service at the job site provided the owner agrees to pay the Dealer for all travel time including mileage and test equipment as well as any expenses incurred ov
10. 528 M372 O1 Rev D e PZ3000 Series INSTALLATION 1 Carefully remove the scale base and display from the shipping carton and inspect them for any evidence of damage such as exterior dents and scratches that may have taken place during shipment Remove the packing material from the scale base and on the PZ3030 the shipping screw on the bottom of the scale base Next remove the protective covering from the display and keypad Keep the carton packing material and shipping screw on the PZ3030 for return shipment if it should become necessary NOTE It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit 2 mount the display on the scale base locate the two mounting screws on the display and the two slotted holes in the scale base bracket 3 Lift the scale by the bracket high enough to allow you to align the two screws on the display with the large end of the two slotted holes in the bracket Place the screws on the display in the bracket and gently pull forward to secure the display to the bracket 4 Plug the AC power supply into the power jack located on the bottom side of the display refer to Figure 1 and then connect the AC power adapter into the proper electrical outlet 5 lfitis desired to use the scale remotely no AC power with the exception of the PZ3060 you must first obtain and install 6 NiMH batteries 2300mAh minimum The batteries should then be allowed to charg
11. O3M ANO JSN ITEM PART NUMBER DESCRIPTION 6013 0039 NUT HEX 46 32 6021 0654 SCW PAN HEAD 46 32 x 250 PDMS 6021 0687 SCW TRUSS HEAD 6 32 312 THMS 6680 0004 WASHER LOCK INT TOOTH 6 Z P 8528 B272 08 LABEL BATTERY REQ PZ2500 BATTERY NiMH 1 2V 2700mAH AA SIZE 6800 0020 Included on PZ3060 Optional on PZ3015 PZ3015L amp PZ3030 Not Shown 16 8528 M372 O1 Rev D e PZ3000 Series PARTS IDENTIFICATION PZ3015 Base Assembly 8528 M372 O1 Rev D e PZ3000 Series w B PARTS IDENTIFICATION PZ3015 Base Assembly 427R1366 427R1365 587R9378 6021 1124 6021 1258 6021 1074 6560 0021 593GR986 6540 1004 6610 3000 6980 0004 6610 5007 6540 1058 8528 B110 0A 8528 B392 0A 1 16 1 8534 C623 0A 4 18 593R1021 ITEM QTY PARTNUMBER DESCRIPTION 1 1 42881079 DECAL COMMODITY TRAY LOAD CELL ASSY LOAD CELL SPACER 410 32 X 75 SOC HD S S 10 32 X 375 SET SCW 10 32 X 5 FHMS S S LOCTITE SERIAL TAG RUBBER FOOT CONNECTOR HOUSING STRAIN RELIEF CABLE LOAD CELL 9 FT CABLE CLIP SCALE BASE HUBBER PAD LABEL 18 8528 M372 O1 Rev D e PZ3000 Series PARTS IDENTIFICATION PZ3015L PZ3030 Base Assembly W V GREEN RED WHITE BLACK 8528 M372 O1 Rev D e PZ3000 Series 19 PARTS IDENTIFICATION PZ3015L PZ3030 Base Assembly DESCRIPTION x 1 1 8528 C262 0A BASE PLATE
12. S key to step through selections for a new value and then press ZERO key to save it Allowable values are 0 Disable Beeper 1 Enable Beeper 8528 M372 O1 Rev D e PZ3000 Series 11 SETUP and CALIBRATION Cont FLtz Digital Filter Level Selection Your scale will arrive with factory filter settings of 0 Minimal PZ3060 will be 2 Heavy Please check with Tech Support before changing filter level break range and sample rate Press ZERO key to show current setting If value displayed is acceptable press ZERO key again to save it Otherwise use UNITS key to step through selections for a new value and then press ZERO key to save it Allowable values are 0 Minimal Filter 2 Heavy Filter 1 Moderate Filter Custom Filter NOTE If 3 Custom Filtering is selected three additional prompts will be displayed LCLUL Filter Level Press ZERO key to show current setting If value displayed is acceptable press ZERO key again to save it Otherwise use UNITS key to step through selections for a new value and then press ZERO key to save it Allowable values are 1 least amount of filtering to 99 greatest amount of filtering br Break Range Press ZERO key to show current setting If value displayed is acceptable press ZERO key again to save it Otherwise use UNITS key to step through selections for a new value and then press ZERO key to save it Allowable values are 1 to 99 which correspond to the number of division changes
13. e approximately 8 hours Charging the batteries for more than 8 hours Will not harm them The scale may be operated while the batteries are charging 6 Place the scale on a stable vibration free level surface away from direct sunlight and any rapidly moving air source heating and cooling vents 7 Place commodity tray on the scale The scale is now ready to use DO NOT place the scale on an unstable cart stand or table The scale may fall causing injury or damaging the scale or proper operation may be inhibited Display Mounting Screws Optional Zero Device Connector Power Supply Jack Scale Base Cable 8528 M372 O1 Rev D e PZ3000 Series 3 POWER CONNECTION NOTE The PZ3000 can be operated from a power supply or from 6 AA size 2300mAh minimum NiMH batteries The power supply is also used to recharge the NiMH batteries Batteries are available by ordering Cardinal part number 6800 0020 Power Supply To power the PZ3000 using the power supply connect the power supply s connector into the power jack on the bottom side of the display and then connect the 12 VDC 1 Amp power adapter into the proper electrical outlet See Figure 1 On models requiring 220 VAC it is the customer s responsibility to obtain the correct power adapter plug The scale is now ready for operation Battery Operation Battery operation is a standard feature of the PZ3000 Series Ingredient Scale although the batteries are opti
14. e receptacle Does it work Check the circuit breaker Has there been a power failure of any kind Are the batteries discharged Incorrect Weight Reading Insure that the scale platform isn t touching an adjacent object The display will show an incorrect weight when there is a product buildup under the platter Clean the platter and place on the scale platform securely Test with a known amount of weight to see if the correct weight is displayed Have proper operation procedures been followed If problem persists the scale may need re calibration Contact your scale serviceman Error Messages DISPLAY POSSIBLE CAUSE CORRECTIVE ACTION This message indicates that motion Insure scale is on a stable vibration free is present when attempting to level surface away from any rapidly moving perform one of the following air source such as heating and cooling operations Power Up or Pressing vents NOTE When attempting to zero the ON OFF key on the keypad scale wait for a stable weight display This message indicates an attempt the scale is at zero If problem to display a negative weight greater persists contact your scale serviceman than 9 Ib 15 oz This message indicates the weight on scale exceeds the scale capacity Insure the scale is at zero If problem persists contact your scale serviceman scale needs calibration The load cell input is below the range of the indicator EcecHH The load cell
15. ector OPTIONAL ZERO DEVICES In addition to the standard display pushbutton and Lite Way hands free methods to zero the weight the PZ3000 Series has an optional Foot Pedal or Mountable Pushbutton available The model numbers for the optional zero devices are PZFS for the foot pedal and PZPB for the mountable pushbutton Figure No 7 Power Optional Supply Zero Device Jack Plugs in Here 8528 M372 O1 Rev D e PZ3000 Series 7 KEYPAD DESCRIPTION The PZ3000 display is equipped with a membrane keypad containing 3 keys and the LITE WAY photo eye sensor The keypad is shown in detail in Figure 8 GROSS kg POUNDS gt OUNCES X DETECTO www detectoscale com Figure No 8 DO NOT operate the keypad with pointed objects pencils pens etc Damage to keypad resulting from this practice is NOT covered under warranty gt The following describes the use of each key Pressing this key will apply power to the instrument and turn on the scale Note that you must press and hold the key for approximately 2 seconds for the scale to power up If the scale is already on pressing this key quickly will turn the scale off This key is also used to lock the weighing units Refer to the Operation section of this manual for instructions on locking the weighing units This key is used to select the units in which the weight is to be displayed The available units include pounds only ounces only
16. er the direct labor of the technician at the job site This limited warranty honors only labor performed by Detecto authorized dealers This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does not include replacement of expendable or consumable parts This does not apply to any item which has deteriorated or damaged due to wear accident misuse abuse improper line voltage overloading theft lightning fire water or acts of God or due to extended storage or exposure while in purchaser s possession This warranty does not apply to maintenance service Purchased parts will have a ninety 90 day repair or replacement warranty only Detecto may require components be returned to the factory they must be properly packed and shipping charges prepaid A return authorization number must be obtained for all returns and marked on the outside of all returned packages Detecto accepts no responsibility for loss or damage in transit STATEMENT OF LIMITED WARRANTY Conditions Which Void Limited Warranty This warranty shall not apply to equipment which A Has been tampered with defaced mishandled or have had repairs and modifications not authorized by Detecto B Has had serial number altered defaced or removed C Has not been grounded according to Detecto s recommended procedure Freight Carrier Damage Claims for e
17. hing units can be locked to a specific unit For example if during Setup and Calibration the scale was configured and calibrated in Pounds Only and you only want to weigh in Pounds Ounces with the Fraction displayed you would need to perform the following 1 Press and hold approximately 2 seconds the ON OFF key until the scale is powered up 2 Press the UNITS key until the desired weighing units is shown on the display the annunciators and or fraction for the desired unit are turned on 3 Press and hold the ON OFF key for approximately 2 seconds The scale will beep and the display will show L indicating the selected weighing unit is now locked 4 Once the weighing units are locked the scale will always power up in the locked units and not in the units the scale was calibrated in Note that even though the weighing units are locked pressing the UNITS keys will still step through the alternate units 5 To unlock the weighing units press and hold the ON OFF key for approximately 2 seconds The scale will beep and the display will show Unt ac CARE and MAINTENANCE The heart of the PZ3000 Ingredient scale is a precision load cell located in the center of the scale base It will provide accurate operation indefinitely if protected against overload of scale capacity dropping items on scale or other extreme shock DO NOT submerge pour or spray water directly on the scale base or weight display DO NOT expose the scale base o
18. ing right a series of dashes will appear on the display The dashes will disappear and the display will change to of F and the scale will turn off STORE SETUP AND CALIBRATION To complete setup and calibration and store setup and calibration data perform the following 1 Press and hold approximately 2 seconds ON OFF key until scale is turned on The display will immediately change to of F and the scale will turn off Setup and calibration data is now stored in scale s nonvolatile memory Press and hold approximately 2 seconds ON OFF key until scale is turned on Scale is now ready for operation 8528 M372 O1 Rev D e PZ3000 Series 13 A O N TROUBLESHOOTING The following describes conditions you may encounter while operating this scale Instructions are provide to help you correct the problem If you are still unable to resume normal operating functions please contact your nearest scale technician or our Technical Support Department Negative Weight Display The scale will display a negative weight when the scale base has been emptied or partially emptied without re zeroing the scale To re zero the scale press the ON ZERO key wait for the display to read zero and start the procedure again No Weight Displayed Is the power supply cable plugged into the PZ3000 display Is the AC power adapter plugged into a wall receptacle Check the wall receptacle for proper AC power Try another electrical appliance in the sam
19. onal not included except on model PZ3060 The scale will operate for up to 50 hours on fully charged batteries depending on the condition of the batteries from new to about 500 recharges The battery bar graph indicates the battery capacity in 4 steps 4 segments the full battery capacity is available 3 segments the battery is at 75 of capacity 2 segments the battery is at 50 of capacity 1 segment the battery is at 25 capacity When the battery voltage drops too low for accurate weighing the display will show obt and then shut off You will be unable to turn the display back on until the AC power supply is connected to the display to operate it and recharge the batteries Battery Charging To recharge the NiMH batteries the AC power supply must be connected to a power outlet and plugged into the display It will take approximately 4 to 8 hours to fully recharge the batteries in the display Charging the batteries for more than 8 hours will not damage them NOTE The scale may be operated while the batteries are charging Battery Installation Replacement To install or remove the batteries the following steps should be followed 1 Remove the indicator from the scale wall or table stand 2 Turn the indicator so that the display is facing away from you and place it face down on a table or bench 3 Referring to Figure No 2 locate the two screws on the angled edge of indicator NOTE The PZ3015 and PZ3030 u
20. quipment damaged in transit must be referred to the freight carrier in accordance with freight carrier regulations This warranty sets forth the extent of our liability for breach of any warranty or deficiency in connection with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or contract Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured The foregoing is in lieu of all other warranties express or implied including any warranty that extends beyond the description of the product including any warranty of merchantability or fitness for a particular purpose This warranty covers only those Detecto products installed in the forty eight 48 contiguous continental United States Ph 800 641 2008 E mail detecto Q cardet com tr T T 203 E Daughert f Webb City MO 64870 Printed in USA A Division of Cardinal Scale Manufacturing Co D268 7 B 7 7 g WARRANTY DET e
21. r display to direct sunlight or temperature extremes DO NOT place the scale base or display in front of heating cooling vents DO NOT use acetone thinner or other volatile solvents for cleaning DO clean the scale base or display with a damp soft cloth and mild non abrasive detergent DO remove power before cleaning with a damp cloth DO provide clean AC power and adequate protection against lightning damage DO keep the surroundings clear to provide clean and adequate air circulation 10 8528 M372 O1 Rev D e PZ3000 Series SETUP and CALIBRATION Your PZ3000 Ingredient scale has been pre configured at the factory and should not require configuration for use in most applications In the event that the factory settings do not meet the requirements of your application the following describes the steps to configure the scale IMPORTANTI The display and scale base are a matched pair Do not switch them refer to S N tags without recalibration To Begin Setup and Calibration 1 Press and hold the ZERO key Press and hold the ON OFF key until the scale display shows 3 Release the ON OFF key The display will change to show Fhoto iz Release the ZERO key to enter the setup mode 3 3 C2 3 _ Je em _ gt N During setup and calibration it will be necessary to enter data using the scale s keyboard x Pressing the ZERO key will show the current value of a setting Pressing the ZERO key again will save the displayed se
22. re Setup and Calibration press ZERO key again To begin calibration press UNITS key to select 1 YES calibrate scale and then press ZERO key Display will change to L Gd Lund Load Calibration Weight The display will change to L GA dz which is a prompt for the entry of the calibration weight value and placement of this amount of test weights on the scale platform 1 Make certain the scale platform is empty and free of debris then place the desired amount of calibrated test weights on the scale platform It is recommended that a minimum of 50 of the scale s capacity be used but 7096 to 100 is preferred 2 Press the ZERO key 3 Determine the exact amount of test weights to be placed on the scale platform and then using the UNITS key and the ON OFF key select this value Note that the cursor location is identified by the blinking character and can be advanced to the next position left by pressing the ON OFF key Pressing the UNITS key will change the blinking character to the next value Verify that the numbers selected are the same as the total weight of the test weights 4 Press the ZERO key 5 Starting at the left and proceeding right a series of dashes will appear on the display The dashes will disappear and the display will change to Got d unc ad Unload Calibration Weight With display showing Uni g remove the test weights from the scale platform 1 2 Press the ZERO key 3 Starting at the left and proceed
23. se use the UNITS key to step through the selections for a new value When the desired value is displayed press the ZERO key to save it Allowable values are 1 2 or 5 12 8528 M372 O1 Rev D e PZ3000 Series SETUP and CALIBRATION Cont dPP Decimal Point Position With the display showing 222 press the ZERO key to show the current setting If the value displayed is acceptable press the ZERO key again to save it Otherwise use the UNITS key to step through the selections for a new value When the desired value is displayed press the ZERO key to save it Allowable values are 1 XXXXX X 2 XXXX XX 3 XXX XXX LAF Scale Capacity With the display showing 22 z press the ZERO key to show the current setting If the value displayed is acceptable press the ZERO key again to save it Otherwise use the UNITS key and the ON OFF key to select the capacity Note that the cursor location is identified by the blinking character and can be advanced to the next position left by pressing the ON OFF key Pressing the UNITS key will change the blinking character to the next value Verify that the numbers selected are the same as the weight listed on the capacity label and then press the ZERO key to save it LAL Calibration With display showing RL press ZERO key The display will change to show current setting U 0 NO skip calibration If scale has been previously calibrated and you wish to skip calibration and proceed to Sto
24. se two thumbscrews and the PZ3060 uses two socket head cap screws instead of thumbscrews 4 Remove the screws and washers under them 5 Lift the battery door exposing the Remove these Screws battery holder 6 Referring to Figure No 3 locate and remove the connector on the end of the battery holder 4 8528 M372 O1 Rev D e PZ3000 Series POWER CONNECTION 7 Slide one side of the battery door so that it clears the edge of the indicator enclosure and then remove the battery door 8 Place the battery door on a table or bench with the battery holder and battery strap up 9 Referring to Figure No 3 remove the 2 Philips screws securing the battery strap to the battery door and remove the strap Battery Strap Battery Connector Remove Philips Screws 10 To install or replace the batteries first remove the battery holder cover by pushing in on the tab and lifting it up Refer to Figure No 4 11 1f replacing the batteries remove all 6 batteries from the battery holder If installing new batteries proceed to step 12 NOTE To insure optimum performance of your PZ3000 when powered by the internal battery replace all 6 batteries with new AA size NIMH batteries 2300mAh minimum DO NOT mix new and used batteries Figure No 4 Battery Cover Push in and lift here 12 Install the 6 new AA size batteries in the battery holder noting the polarity markings located in the ba
25. to break out of filtering 5r Sample Rate Press ZERO key to show current setting If value displayed is acceptable press ZERO key again to save it Otherwise use UNITS key to step through selections for a new value and then press ZERO key to save it Allowable values are a minimum of 1 sample per second to a maximum of 16 samples per second in one sample per second intervals Un it 5z Weighing Units Press ZERO key to show current setting If value displayed is acceptable press ZERO key again to save it Otherwise use UNITS key to step through selections for a new value and then press ZERO key to save it Allowable values are 1 Pounds Only 4 Kilograms 2 Ounces Only 5 Pounds Ounces with Decimal Point 3 Pounds Ounces with Fraction 6 Grams NOTE If 3 Pounds Ounce with Fraction is selected an additional prompt Fr Rc will be displayed In addition the ot Interval Setting and dP Decimal Point Position will be skipped Fr RL Fraction Interval Press ZERO key to show current setting If value displayed is acceptable press ZERO key again to save it Otherwise use UNITS key to step through selections for a new value and then press ZERO key to save it Allowable values are 0 No Fraction 2 1 2 4 1 4 8 1 8 int Interval Setting With the display showing nt press the ZERO key to show the current setting If the value displayed is acceptable press the ZERO key again to save it Otherwi
26. ttery holder Refer to Figure No 5 13 After placing all 6 batteries in the holder replace the battery cover and battery strap Secure the battery strap with the 2 Philips screws removed earlier 14 Replace the battery door on the indicator and then re connect the connector on the end of the battery holder 8528 M372 O1 Rev D e PZ3000 Series 5 POWER CONNECTION 6 AA Size NiMH Batteries 2300mAh minimum 15 Insuring no wires are between the battery door and the back of the indicator lower the battery door 16 Install the two screws and washers removed in step 4 NOTE The PZ3015 and PZ3030 use thumbscrews and should be finger tightened only 17 Return the indicator to the scale wall or table stand 18 Apply power to the PZ3000 using the power supply to begin charging the new batteries 19 The scale is now ready for operation Extended Battery Operation In operations that require the remote use no AC power of the scale beyond the approximately 50 hours of continuous use an auxiliary battery door assembly CPN 8528 C365 0A and 6 AA size 2300 mAh minimum batteries CPN 6800 0020 can be purchased to easily accommodate your operation The following steps describe how to remove the battery door and re charge the batteries externally using the AC power adapter battery charger 1 Remove the indicator from the scale wall or table stand 2 Turn the indicator so that the display is facing away
27. tting value and advance to the next prompt To change a setting press the UNITS key to toggle between the different available values On settings with 2 digit values press the ON OFF key to advanced to the next position Note that the blinking character is the cursor location of the value to be changed To exit setup press the ON OFF key at any prompt Photo iz LITE WAY Photo Eye With the display showing Photo press the ZERO key to show the current setting If the value displayed is acceptable press the ZERO key again to save it Otherwise use the UNITS key to step through the selections for a new value When the desired value is displayed press the ZERO key to save it Allowable values are 0 Wavy Zero Turned Off 1 Wavy Zero intensity set to 0 to 2 inches 2 Wavy Zero intensity set to 6 inches maximum KT bAL Lt Back Light With the display showing bfc Lt press the ZERO key to show the current setting If the value displayed is acceptable press the ZERO key again to save it Otherwise use the UNITS key to step through the selections for a new value When the desired value is displayed press the ZERO key to save it Allowable values are 0 Back Light Turned Off 1 Back Light set to continuously on 2 Back Light comes on after key press or change in weight er bEEP Beeper Press ZERO key to show current setting If value displayed is acceptable press ZERO key again to save it Otherwise use UNIT

Download Pdf Manuals

image

Related Search

Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manual arts high school manually update your device drivers windows manual definition manual for courts martial manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manual transfer switch manualidades manual blood pressure cuff manual handling manual transmission cars for sale manual digital manual pdf manual autopilot enrollment