Home

USER`S MANUAL

image

Contents

1. Storage Temperature 20 ATO Maximum 0 90 non condensing Type of Cooling O D o D Oo D pj o D S a 5 lo lo 3 2 a o 2 ls T Forced with fan lt D D fe h Q fe o 5 a lt 3000 meters elevation 420 160 218mm O 5 n 3 E oo D S O JO J 5 I ia Q Weight w o Battery 11kgs 14kgs 16kgs 20kgs DESIGN MANUFACTURE SERVICES ISO 9001 Operation Front Panel Controls and LCD Indicators Shown below are the controls and indicator lights on the front of Inverter Charger t 0 25 50 75 100 10 11 1 Power On Please make sure the battery connection before you turn on the Inverter Charger 2 UPS Off 3 Charger Only 4 UPS Test Switch When UPS is working under AC mode it also activates the UPS s self test by press the bottom 5 Line On AC Normal 6 O Temp If the UPS is over temperature the light will turn on and the alarm will sound continuously 7 Back Up Battery in back up 8 Over Load If the UPS is overloaded the light will turn on and the alarm will sound continuously 9 UPS Cut Off Overload or Cut off 10 Battery Level A bar graph showing how much of the UPS battery is being used 11 Load Level A bar graph showing how much of the UPS power is being used Step 3 Connect battery cables to your batteries gt Single battery connection When using a single battery its v
2. P N 41 NE IN100000 A00 General Precautions 1 Before using Inverter Charger read all instructions and cautionary markings on 1 Inverter Charger 2 the batteries 3 this manual 2 CAUTION To reduce risk of injury charge only lead acid type rechargeable batteries Other types of batteries may cause damage and injury 3 Do not expose Inverter Charger to rain snow or liquids of any type Inverter Charger is designed for indoor 4 Do not disassemble Inverter Charger Take it to a qualified service center when service or repair is required 5 WARNING Provide ventilation to outdoors from the battery compartment The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment 6 NEVER charge a frozen battery 7 Be extra cautious when working with metal tools around batteries Short circuiting the batteries could cause an explosion 8 For battery installation and maintenance read the battery manufacturer s installation and maintenance instructions prior to operating Personnel Precautions 1 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 2 Avoid touching eyes while working near batteries 3 Never smoke or allow a spark or flame in vicinity of a battery 4 Remove personal metal items such as rings bracelets necklaces and watches when working with batteries Batteries can produce a short circuit current
3. high enough to make metal melt and could cause severe burns 5 If a remote or automatic generator start system is used disable the automatic starting circuit or disconnect the generator to prevent accident during servicing USER S MANUAL Inverter Charger IP Inverter 13 Specification MODEL mooo m1500 N3200 1000VA 1500VA 2000VA 3200VA CAPACITY VA Watts SOOW 900W 1200W 2000W INPUT 115VAC 230VAC 1 Phase Neutral 90 135VAC 187 264VAC 4 24VDC DC 47Hz 53Hz 57Hz 63Hz 3Hz in Battery Mode Maximum 10 milliseconds Frequency Tolerance Voltage Waveform Modified Sinewave Voltage Tolerance 10VDC 14VDC 20VDC 28VDC OUTPUT Voltage 115VAC 230VAC Voltage Tolerance 7 50Hz or 60Hz BATTERY Maintenance free dry type suggested Capacity Up to 1000Ah Battery Low Level 10 8V 0 2V 21V 0 5V Battery Cut off Level 10V 0 2V 20V 0 5V Battery house External Rack or Cabinet Optional CHARGER Battery Charge Voltage 13 6VDC 0 2VDC 27 5V 0 3V Charge Capacity 40A max Adjustable Over Charge Protection 14 5VDC 0 5VDC 29V 0 5V INDICATORS Control Panel On Off button Battery charge current adjustment amp CONTROL l lt 7 Line Mode T PANEL ndicators Line Mode Line On LCD lighting O Temp LCD lighting 5 Step LCD lighting PROTECTION Over load Short circuit Over charge Over temperature Input Full Protection amp Output fuse Less than 45 dBA at 1 meter oc 40 C
4. N1500 900W 125A 4AWG 2 IN3200 2000W 140A 2AWG 2 Introduction The Device is a DC to AC inverter with auto line to battery transfer and integrated charging system serving as an extended run UPS a standalone power source or an automotive inverter Inverter Charger supplies power from AC power and DC source When AC cable is connected to a wall socket utility power goes to connected equipment s and or charges the battery set via charging system In UPS mode Inverter Charger automatically convert battery energy into AC power for backing up the connected devices Features 30Amp built in powerful smart charger for long backup time and extended battery life High efficiency and low idle current to keep low operating costs Quiet operation heavy duty reliability Ecologically smart and user friendly Back up on line battery status power status by LCD display Short circuit and overload protection Cold start DC power on Advanced battery management ABM S BN AN A A N N A Charging current can be adjusted by selector
5. oltage must be equal to the voltage of Inverter Charger Nominal Input Voltage See specs gt Series battery connection When using multiple batteries in series all batteries must be equal in voltage and amp hour capacity and the sum of their voltages must be equal to the voltage of Inverter Charger Nominal Input Voltage see specs gt Parallel battery connection When using multiple batteries in parallel each battery s voltage must be equal to the voltage of Inverter Charger Nominal Input Voltage see specs Step 4 X Charger Current Switch You can adjust the position of Dip Switch to adjust charging currency of battery za oa BS mey 1 2 330Amp 40Amp 42320Amp 30Amp 2310Amp 20Amp 235Amp 10AMP Back Panel Description Shown below are the components on the back of Inverter Charger NEMA5 15R SCHUKO UNIVERSAL 1 Input Breaker 2 AC Input Connector 3 Output Receptacle s 4 DC Input Connector Battery Terminal 5 Output Breaker Battery Connection Step 1 Connect to 12V 24V battery is positive is negative Reverse polarity connection will blow internal fuse and may damage inverter permanently See Specification Step 2 DC to AC inverters require high amperage low voltage DC power to low amperage high voltage AC power To operate properly connect inverter DC input terminals direct to battery with heaviest wire available no more than 100cm see chart below I

Download Pdf Manuals

image

Related Search

Related Contents

Chicago Electric 93218 Cordless Saw User Manual  Sharkoon Fireground  SMARTEYE Sender/Receiver Reader User Manual  Epson WorkForce WF-5690DWF    

Copyright © All rights reserved.
Failed to retrieve file