Check List:

image

Contents

1. Max Cable distance is calculated at less than 5 voltage drop 40Amp DC Solar Y Lead z Solar Connector a am P5512 sow 125Amp DC PS 5102 S Solar Panel 30Amp DC ggg Solar Connector Solar Y Lead 250Amp DC PS 5100 PS 5112 Battery Fuse DIP Switch Settings No3 ON Up 1 24 5 6 7 8 OFF BDC Network Switch Settings No 1 CombiNet Address 1 From SuperCombi PORT C EXT To DC SW ML5258 SunStar SS 60C Settings DC SW 140 Settings Main Menu gt Programming gt ENT gt Communication gt ENT Communication settings P1 01 2 CombiNet Mode P1 04 1 CombiNet Address 1 Main Menu gt Programming gt ENT gt General gt ENT gt DC SW Operation Sel gt ENT B1 01 0 DC DC Charger Main Menu gt Programming gt ENT gt General gt ENT gt Set Battery Voltage gt ENT B1 02 12 Battery Voltage 12VDC MP 3726 DC SW 140 Small Ground cable from DCSW Battery Bank 12VDC SB 1822 Alternator Start Battery ATdWVXA4 DIJEWIADYIS 12JOS HEM OZE W JS S 1 MOd
2. 76 Absorb Bulk 27 6V D1 07 23 76 Float 26 76V DI 10 0 Equalization charge OFF 12V System D1 03 13 80 Absorb Bulk 13 8V D1 07 13 50 Float 13 5V D1 10 0 Equalization charge OFF D1 08 Please DO NOT ADJUST the battery charger current D1 08 Unless you have consulted with us first General Installation Checklist Checked LV wiring must be installed by a qualified electrical tradesperson Safe isolation must be provided between ELV and LV Circuits Over current protection and isolation are rated for AC or DC at the appropriate voltage and currents Shutdown procedure is prominently displayed Access to equipment such as batteries is restricted to authorised personnel Adequate ventilation is provided to all electrical equipment All cables satisfy both voltage drop and current carrying capacity All exposed cabling is provided with mechanical protection Lighting protection has been provided if required Equipment is labelled convenient accessible and visible There are no live parts accessible on any installed equipment Main Battery over current protection installed in all un earthed conductors A means to readily isolate the battery bank is installed The batteries are installed in a appropriate ventilated dedicated room enclosure or restricted access area designed to prevent unauthorised entry Warning Spark Hazard sign is mounted above or next to the batteries Battery warning signs DANGER Risk
3. Print Form SVEGIRIEG SuperCombi amp CombiPlus Quick Install amp Programming Check List for Recreational Power Systems This check list provide basic programming and commissioning information for your Combi Series Inverter in a Caravan RV amp Marine Applications Please make sure you have read and understood the User Manual before attempting to power up you Combi inverter If you are unsure please contact powertech jaycar com au This checklist should be used in conjunction with AS 3000 Wiring Rules Recreations Power System design must comply with you local mandatory requirements and should follow the recommendations of AS4509 2 SPS Design Guidelines Ana VC ATAATA Pure Sine Wave Interactive Inverter Charger 1500W 12V Recommended cable size 0AWG up to 2m 1500W 24V Recommended cable size 2AWG up to 2m 3000W 12V Recommended cable size OOOAWG up to 2m 3000W 24V Recommended cable size 0AWG up to 2m Minimum Battery 100Ah 200Ah Capacity Ah Recommended 53 5 mar 33 6 mm 85 mm 53 5 mm Cable Size oAWG 2AWG 000 AWG OAWG NOTE Consult your battery manufacturer for correct battery sizing for your application Battery cable sizes are based on recommended cable length of 2 meters Longer cable lengths will require large cable sizes MAX DC Fuse Size 1500W 12V 250Amp 1500W 24V 125Amp 3000W 12V 500Amp 3000W 24V 250Amp Note e Protection is requir
4. aker Breaker Size recommendations if not using the Boosting feature or AC Generator Model MCB RCD Curve Type 1500watt 6 Amps C Type Standard 3000watt 10 Amps C Type Standard 6000watt 20 Amps C Type Standard B2 01 08 AC Input Voltage amp Frequency Input Check Table Checked The following Check Table is a summary of the following sections Setting Function B2 08 0 When B1 01 0 Acceptable AC input frequency is 50Hz 5Hz 45 55Hz When B1 01 1 Acceptable AC input frequency is 60Hz 5Hz 55 65Hz Accept wide AC input frequency range between 45 65Hz AC Low input Cut out Voltage _ 190VAC AC Low input Cut in Voltage _ 197VAC AC High input Cut in Voltage _ 255VAC AC High input Cut out Voltage _ 260VAC B2 05 AMPS _ AC Input Current 3 33x VA of AC Generator AMPS When using a Generator then you must always use wave B2 06 1 eae form check Active Active B2 07 1 The internal ground relay is closed Internally the Neutral amp GND are joined when in inverter mode only AC Out MODE 2 B2 09 1 B2 09 1 Dynamic Power Dynamic Used this feature when operating smaller AC Generator less than 3kVA AC load is supported by the Inverter then slowly pushed across to the Generator MODE 1 B2 09 0 B2 09 0 Dynamic Power Normal Select Normal when operating larger AC Generators or when connected to Mains Grid The AC load
5. ed on both Positive and Negative cables when the battery is NOT earthed Never connect TWO battery banks via a switch Warning Check Polarity Before Connection 1500W 12V 200Ah 12V C10 1500W 24V 100Ah 24V C10 3000W 12V 400Ah 12V C10 3000W 24V 200Ah 24V C10 Note C10 Rate refers to the Amperage discharge over a 10 Hour period AC Wiring Connections to Combi Checked The AC Input Current limit from the AC Generator or Mains Grid supply must be set in the Combi s AC Input Current setting B2 05 The length of the AC input cable is also required to calculate the correct size that should be used when allowing for maximum input and outputs Inverter AC Input MIN AC Cable Size MCB RCD single Twin core and earth MAX Circuit Breaker Current Enclosed conduit Unenclosed free air 16Amp 2 5mm 15mm 32Amp 6mm 4mm 63Amp 16mm 10mm Inverter AC Output SuperCombi MIN AC Cable Size MCB RCD single Twin core and earth SuperCombi MAX Circuit Breaker Current Enclosed conduit Unenclosed free air 25Amp 4mm 2 5mm 50Amp 16mm 100Amp 35mm Note Never connect the AC supply without the battery connected If you are not using the boosting feature from the AC input you can prevent the Combi from going into over load by using a smaller AC Breaker on the output side of the inverter Example 500W use 6 Amp for the 3000W use 10 Amp standard C Type bre
6. is supported directly by the AC Generator or Mains Grid B2 08 AC Input Frequency Checked Check the AC Input and Frequency ranges are set correctly The default setting is for wide range of voltage and frequency If your system is using a cheaper style generator we recommend you adjust the Combi for a more selective range Example B2 08 0 45 55Hz Narrow range B2 08 1 45 65Hz Wide range B2 01 04 AC Input Voltage Checked If your system is using a cheaper style AC Generator we recommend you adjust the Combi for a narrower voltage range to offer better protection to your appliances and the Combi These Voltage input parameters can be adjusted Example LOW B2 01 190VAC and B2 02 197VAC HIGH B2 03 255VAC and B2 04 260VAC B2 05 AC Input Current Checked e Itis very important to correctly program your Combi to suit the size of your AC Generator or Mains Supply If you don t Power Share Power Support Dynamic Power Shifting will NOT work Furthermore you can overload your inverter e MODE I Never set the Combi s AC input B2 05 amp B2 18 higher than 16AMPS we recommend 13 15Amps to avoid tripping of the Shore power breaker Remember that you MUST be operating in MODE 1 when you are programming these steps MODE 2 YOU MUST Never set the Combi s AC input B2 05 amp B2 19 higher than the Continuous output rati
7. ng of your AC Generator or mains supply Remember that you MUST be operating in MODE 2 when you are programming these steps Generally a good rule of thumb is take the AC Generators kVA rated output and multiply it by 3 33 Example If you have a 3 6kVA AC Generator then the maximum AC Input Current is 3 6 x 3 33 12 Amps 11 99 e We recommend you use this rule to set the AC Input Current to the Combi This is programmed into B2 05 settings also check B2 18 21 these should be the same value as set in B2 05 We recommend the use of inverter style AC Generators USE ONLY Mode 2 for AC Generators and MODE 1 AC Input setting should be 13 15Amps Max 16Amps For more on Mains AC connected systems please refer to the User Manual B2 06 AC Input Current Checked e B2 06 1 Active When using a Generator then you must always use wave form check Active B2 07 AC Ground Relay MEN Checked e B2 07 1 Closed For use in Marine and Caravan installations were there is NO MEN point on the AC output then the Ground Relay must be activated See AS3000 for more info Battery Charger Settings Checked Check that the correct charger voltages have been adjusted to suit your battery e Failure to do so can destroy your batteries and could damage the Combi Example PowerStacks SB 1800 amp SB 1802 amp PowerSleak SB 1822 AGM 24V System D1 03 26
8. of Battery Explosion and Electrolyte Burns are clearly visible There are NO arc producing devices in the area ELV cables are to be labelled to identify solar and DC circuits and cabling SunStar SS 45C MP 3726 EXAMPLE 4x 80 Watt Solar Panels AC Generator SuperCombi 1500W Power MI 5250 MODE 2 ff _From superCombi PORT c EXT Set B2 05 amp 18 Note This is a RISO MOD10 connection AC Input Current ete Tires 333xKVArating ith 10 core cable WI 5252 See checklist for Supercombi Settings Important Make Sure 82 05 AC Input Has been programmed correctly B2 05 amp 18 15 AC input 15Amps Mode 1 operating for Mains power Mode 2 operation for AC Generator B2 05 amp 19 3 33x KVA Generator Note Mode 2 AC Generators Over 3KVA set 82 09 0 Normal Battery Charger Settings 1 03 Absorb Volatge 13 8VDC 1 07 Float Voltag 1 08 Charger Curre D1 10 0 Equalization Charge Off AC load RCD MCB Shore Park Inverter AC Output AC Power RCD MCB MODE 1 Set 82 05 amp 18 15 AC input Cumentisamps 16AMP Max Cable distance from Solar Panels to SunStar Solar Controller 3m 4mm 4 5m 6mm Max Cable distance from SunStar Solar Controller to Battery Bank 6m 8AWG 16m 4AWG Max Cable distance from SuperCombi to Battery Bank 1m 4AWG 1 5m 2AWG 2 5m OAWG Cable size for DC SW 8AWG Max 22Amp 4AWG Max 60Amp 2AWG Max 90Amp OAWG 140Amp 6m Note

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung  Programming WebLogic Web Services  Instalación - Inicio ¿Cómo instalar TELL ME MORE ?  MP3/WMA/CD Player MP-10 User Manual  SterCid Boolklet V10 6page  Jøtul F 600 Woodstove Clearances  aerflu automatic  第100回定時株主総会招集ご通知  Evaluations cm2 2011 - Inspection académique du Morbihan  L`IDENTITE DE SOI par le HO`OPONOPONO®NIVEAU 1  