1. 1 U1 Upward movement Local Input NO Stop Down storing two different codes 2 keys obtains 2 GND shared Signal Input different commands the first for Raising and the second for 3 D1 Downward movement Local Input NO Lowering storing a BeFree radio control 3 keys obtains 4 U2 Upward movement Local Input NO separate commands the first key for Raising the second for 5 GND shared Signal Input Stopping and the third for Lowering 6 D2 Downward movement Local Input NO Operation using a 1 key radio control 7 U3 Upward movement Local Input NO Using the radio control with single key ensures the following 8 GND shared Signal Input operation the first press controls the upward movement for 9 D3 Downward movement Local Input NO the configured motor time The second press controls down 10 U4 Upward movement Local Input NO 11 GND shared Signal Input 12 D4 Downward movement Local Input NO ward movement of the shutter if the key is pressed before the motor stops running the control unit stops the shutter another press of the key reactivates the motor in the opposite direc tion CN3 TERMINAL BLOCK CONNECTIONS Operation using a 2 key radio control 1 24 Vac Sun Sensor Power Output Using the radio control with 2 keys ensures the following op 2 S Sun Sensor Input NO eration the first key Up for raising controls upward move 3 GND shared Input 0 Vac Output ment of the
2. Down for 3 different utilities MX83 or 6 different utilities MX86 Pressing and holding the two side keys and for a few seconds also enables and disables operation of the sun sensor the selection is confirmed by a quick Up Down move ment of the motor ZONE AND GENERAL CENTRALIZATION Centralization with cable and keys The centralization of two or more control units via wire enables simultaneous raising or lowering of the connected shutters To do this you need to connect the control units with a bus of three wires in parallel to the inputs of the General UG Up and DG Down commands and the GND Signal common refer ence This allows you to control the 4 motors independently or si multaneously with the UZ Up and DZ Down zone com mands and centralize other control units with the UG Up and DG Down general commands ANEMOMETER OPERATION The electronic control unit raises the sun shade whenever the wind exceeds the selected threshold SUN SENSOR OPERATION The electronic control unit lowers the sun shade after 10 min utes of brightness greater than the Sun Sensor s selected threshold this is indicated by the SUN LED which lights up The control unit then raises the blind after 10 minutes during which the brightness is below the selected threshold RAIN SENSOR OPERATION The electronic control unit raises the blind as soon as the sen sitive part of the
3. MC9 electronic control unit INITIAL OPERATING CONDITION The control unit allows you to control the 4 motors independ ently using the Local U1 2 3 4 Up or D1 2 3 4 Down con trols and the UZ Up zone DZ Down zone and general UG Up and DG Down simultaneous control keys It is also pos sible to control the 4 motors together or independently using An electronic control unit for the automation of 4 motors for rolling window shutters and or sun blinds with optional con nection of Wind Sun and Rain Sensors and use with pushbut ton control panel and radio control for individual and central ised control one or more radio controls In the default configuration the TECHNICAL SPECIFICATIONS control unit has no radio control stored on its memory Power supply 230V 50 60Hz 1700W max FUNCTIONAL PROPERTIES Workin start erature ie nye a sis Operation with Local Control or Zone Keys Ae 433 92MHy Connection to the U1 U2 U3 U4 UZ and D1 D2 D3 D4 DZ low Compatible radio controls 12 18 Bit Rolling Code voltage inputs of the local control keys normally open for Nr possible radio controls 60 Max running the shutter will ensure the following operation Nr possible wireless sensors 3 Max U1 U2 U3 U4 UZ control raising for the configured motor time Packaging dimensions 490x140x70 mm D1 D2 D3 D4 DZ control lowering of the shutter sending a Container ABS UL94V 0 IP65 command for
4. LEDs flash to confirm this press the SEL key until the SUN SENSOR LED flashes then press the SET key at the same time the SUN SENSOR LED switches on permanently and programming is complete Repeat this procedure to restore the previous configuration 1 RAIN SENSOR Rain sensor control inversion The control unit comes with the Rain control Upward move ment control association so the sensor controls the upward movement of the shutter when it detects the sun If you wish the rain sensor to control the downward movement of the shut ter when it detects the rain proceed as follows enable the ex tended menu the SUN and RAIN LEDs flash to confirm this press the SEL key until the RAIN SENSOR LED flashes then press the SET key at the same time the RAIN SENSOR LED switches on permanently and programming is complete Repeat this procedure to restore the previous configuration RESET If you need to restore the control unit s default settings press the SEL and SET keys together to switch on all the indicator LEDs at the same time and then switch them off again imme diately Rev 1 3 03 12 10 IMPORTANT NOTES FOR THE INSTALLER The control unit was designed to allow the installer to auto mate the shutter in accordance with legislation in force The installer must comply with safety obligations and minimum re quirements Installation must be carried out according to EN 60335 2 97 Specification for safety o
5. both the radio control and pushbutton control this allows you to turn the slats of the Venetian blind ever so slightly to let more or less light into the room as re quired If the commands are more than 2 seconds the blind is raised or lowered depending on the key pressed until the mo tor stops running Step by step Automatic sensors The control unit enables step by step operation as above as well as automatic management of the Wind and Rain sensors Ten minutes after the wind or rain that activated one of the two sensors the control unit lowers the blind Selection mode The control unit allows you to select 4 different operating lo gics step by step manual Venetian blind and step by step automatic sensors The control unit is provided with step by step operation already enabled M1 CODE LED AND M2 CODE LED disabled If you wish to enable the other operating mode proceed as follows enable the extended menu the SUN and RAIN LEDs will flash to confirm this use the SEL key to navigate to the M1 CODE LED then press the SET key to enable the Manual function use the SEL key to navigate to the M2 CODE LED then press the SET key to enable the Venetian blind function or use the SEL key to navigate to the M1 CODE LED and M2 CODE LED then press the SET key to enable the Step by step Automatic Sensors function Rev 1 3 03 12 10 C CODE M3 Simultaneous or sequential start up The control unit is provided with simult
6. checking the sensors operation Anemometer test turn the blades manually the control unit will raise the blind for 5 seconds Sun sensor test expose the Sun Sensor to the sun or light source the control unit switches on the SUN LED and lowers the blind for 5 seconds Cover the Sun Sensor and the control unit will switch off the SUN LED and raise the blind for 5 sec onds Rain sensor test dampen the sensitive part of the Rain Sen sor the control unit will switch on the RAIN LED and raise the blind for 5 seconds At the end of the test make sure you dry off the sensitive part of the rain sensor before using the control unit in normal operating mode Programming The control unit comes with a Line Sensor Test disabled If you wish to enable the Line Sensor Test pro ceed as follows enable the extended menu the SUN and RAIN LEDs will flash to confirm this use the SEL key to navi gate to the SENSOR CODE LED and then press the SET key at the same time the SENSOR CODE LED switches on per manently and programming is complete Repeat this proce dure to restore the initial configuration Important Wireless Sensor test instructions are given in the Wireless Sensor manual F T MOT Automatic Movement Lock The control unit allows you to lock automatic movement Up ward or downward movement of the blind controlled by the Sun Sensor command or function of the Automatic Sensors in this way the control unit temporarily blocks
7. will start flashing very quickly to indicate no more codes can be stored Programming the MX8 3 key radio control The entire MX8 radio control can be configured by pro gramming just the Up Key The MX8 radio control s codes are programmed as follows press the SEL key and M1 CODE LED will start flashing at the same time press the UP key on the required radio control At the same time M1 CODE LED remains ON and program ming will be complete If all the possible radio controls have been stored and you try to repeat the programming phase all the indicator LEDs will start flashing very quickly to indicate no more codes can be stored 2 CODE M2 Programming the radio control for Motor 2 Follow the CODE M1 instructions in paragraph 1 above to program the radio control for motor 2 initially pressing the SEL key twice 3 CODE M3 Programming the radio control for MOTOR 3 Follow the CODE M1 instructions in paragraph 1 above to program the radio control for motor 3 initially pressing the SEL key three times 4 CODE M4 Programming the radio control for MOTOR 4 Follow the CODE M1 instructions in paragraph 1 above to program the radio control for motor 4 initially pressing the SEL key four times CODE ALL Programming the radio control for all 4 motors Follow the CODE M1 instructions in paragraph 1 above to program the radio control for all four motors initially pressing the SEL key five times
8. 5 CODE SENS Programming the wireless sensors Programming the Wireless sensor Sun Wind Rain The Wireless Sensor s transmission code is programmed as follows use the SEL key to select the flashing SENS CODE LED at the same time send the Wireless Sensor code via the dedicated key situated inside the sensor SENS CODE LED stays ON and programming will be complete If the Wireless Sensor code is not sent within 2 minutes the control unit exits the programming phase If all the possible Wireless Sensor codes are already on the memory all the indicator LEDs will start flashing very quickly during the programming operation to indicate no more codes can be stored Deleting the codes Stored Wireless Sensor codes are deleted as follows press the SEL key and SENS CODE LED will start flashing next press the SET key and SENS CODE LED will switch off and the procedure is complete Signalling Should there be no communication between the Wireless Sen sor and the control unit for 20 minutes the shutter is auto matically raised as a safety precaution If communication con tinues to be down other controls will in any case always keep the control unit in safe mode 6 LED T MOT Programming Motor Time max 4 minutes The control unit comes with a motor power time set at two Rev 1 3 03 12 10 minutes LET T MOT OFF The motor time must be programmed as follows when the shutter is down Press the SEL key until the LED T M
9. L SET 1 2 3 4 5 6 7 8 9 1011 12 6 7 8 9f1011 12 13 14 elslelelslelelslelslsle 56B6GSS6GSSS 6 es len ANTENNA 6 Rev 1 3 03 12 10
10. OT key flashes then press and hold the SET key to raise the shutter release the key when the blind is at the required point the motor time is stored at the same time and the LED T MOT key stays ON If you are using an automation system with a stop limit we recommend that you store a time that exceeds the shutter s stop limit by a few seconds If you require unlimited motor time follow the same program ming instructions holding down the SET key for less than two seconds the LED T MOT stays ON and the unlimited time is set The operation may be repeated if a mistake is made dur ing programming 7 WIND SPEED Programming Wind Threshold Displaying the programmed Wind threshold The wind safety threshold selection is displayed as follows use the SEL key to navigate to the WIND SPEED LED the LED then indicates the wind safety threshold whereby every double flash of the WIND SPEED LED indicates an increment of 5 km h e g the WIND SPEED LED flashes 5 times 25 km h Setting the wind safety threshold between 5 and 40 Km h The control unit comes with a wind safety threshold already set at 25 km h WIND SPEED LED OFF The wind safety threshold is programmed as follows use the SEL key to navigate to the WIND SPEED LED then press the SET key to start programming the WIND SPEED LED will then begin to double flash each double flash of the WIND SPEED LED corresponds to an increment of 5 km h Press the SET key once the required thr
11. aneous start up of the 4 motors already enabled If you wish to have a 5 second inter val in between the start up of each motor proceed as follows enable the extended menu the SUN and RAIN LEDs flash to confirm this use the SEL key to navigate to the CODE M3 LED and then press the SET key at the same time the CODE M3 LED switches on permanently and programming is ended Simply repeat this procedure to restore the previous configura tion D CODE M4 Programming the start up delay time The control unit allows you to program a start up delay time for the 4 motors this prevents other interconnected sets of 4 motors from starting up simultaneously The control unit is provided without start up delay time for the 4 motors to pro gram a start up delay time of between 1 and 120 seconds proceed as follows enable the extended menu the SUN and RAIN LEDs will flash to confirm this use the SEL key to navi gate to the CODE M4 LED then press the SET key for the re quired delay time as soon as you release the key the M4 CODE LED switches on permanently and programming is complete Simply repeat this procedure to make any changes to the configuration E SENS CODE Line Sensor Test The control unit allows you to check operation of the con nected sensors and correct movement You are advised to in stall the blind with it half open to check the confirmation movements during the test Make sure you disable the Line Sensor Test after
12. automatic mo tion when a stop command is given during movement until the next raising or lowering command The control unit comes with the Automatic Movement Lock disabled to enable this function proceed as follows enable the extended menu the SUN and RAIN LEDs flash to confirm this press the SEL key until the T MOT LED flashes then press the SET key at the same time the T MOT LED switches on permanenily and pro gramming is complete Repeat this procedure to restore the previous configuration G WIND SPEED Safety Upward Movement The control unit comes with the Safety Upward Movement dis abled to enable this function so that after 12 hours of the Wind Sensor being inactive the control unit automatically exe cutes the safety upward movement proceed as follows en able the extended menu the SUN and RAIN LED will flash to confirm this press the SEL key until the WIND SPEED LED flashes then press the SET key at the same time the WIND SPEED LED switches on permanently and programming is complete Repeat this procedure to restore the previous con figuration H SUN SENSOR Sun sensor control inversion The control unit comes with the Sun control Downward movement control association so the sensor controls the downward movement of the blind when it detects the sun If you wish the sun sensor to control the upward movement of the blind when it detects the sun proceed as follows enable the extended menu the SUN and RAIN
13. eshold has been reached The selected threshold is stored and the WIND SPEED LED stays ON e g the WIND SPEED LED flashes 5 times 25 km h The operation may be repeated if a mistake is made during programming 8 SUN SENSOR Sun Sensor ON OFF Enabling the sun sensor The control unit comes with a Sun Sensor disabled SUN SENSOR LED OFF The Sun Sensor can be enabled as follows use the SEL key to navigate to the SUN SENSOR LED then press the SET key for a second The SUN SENSOR LED stays ON at the same time The Sun Sensor is now enabled Simply repeat this pro cedure to disable the Sun Sensor Enabling the Sun Sensor with 3 key radio control MX83 86 The Sun Sensor can be enabled as follows press and hold for five seconds the key of a previously stored radio control The control unit executes an up down movement for 1 second to confirm the Sun Sensor is enabled and the SUN SENSOR LED stays ON Simply repeat this procedure to disabled the Sun Sensor but pressing and holding the key for 5 seconds instead of the one 9 RAIN SENSOR Rain sensor ON OFF Disabling the rain sensor The control unit comes with a Rain Sensor enabled RAIN SENSOR LED ON The Rain Sensor can be disabled as follows use the SEL key to navigate to the RAIN SENSOR LED then press and hold the SET key for a second The RAIN SENSOR LED switches off and the Rain Sensor is disabled Simply repeat this proce dure to enable the Rain Sens
14. f household and similar electrical ap pliances part 2 Particular requirements for drives for rolling shutters awnings blinds and similar equipment The control unit must be connected permanently to the power supply and it is not equipped with a 230 V a c electric line sectioning device The installer is responsible for installing a sectioning device in the system He should install an omnipo lar switch with category III overvoltage It must be positioned so that it is protected against accidental closure For connections power supply and motors output use flexible cables under insulating sheath in harmonised poly chloroprene HOSRN F with minimum section of the conductors equal to 1 5 mm2 Pay attention while making holes in the outside casing when passing cables for connection and power supply and assem bling the cable glands that everything is installed in a way that keeps IP protection characteristics of the panel un changed as much as possible Pay careful attention when fastening the cables so that they are anchored in a manner that is stable If two or more control units are to be used we recommend you install these at least 3 metres apart to ensure the radio receiver part works correctly In the aforementioned case of two or more control units we recommend you use a single Wireless sensor to avoid radio interference IMPORTANT NOTE FOR THE USER The device must not be used by children or people wit
15. h any psychological or physical disability unless they are supervised or taught how to use it with care Do not let children play with the device and keep the radio controls out of their reach ATTENTION keep this instruction manual and comply with the important safety instructions inside Failure to comply with these instructions could cause damage and serious accidents Inspect the system frequently to check for any signs of dam age Do not use the device if it is in need of repair Attention All operations that require opening the casing cable connec tion programming etc must be executed during installation by a qualified technician Please contact the Technical Assis tance Service should any other work that requires opening the casing arise reprogramming repair or installation changes STATEUROP declares that the products MC9 Conform to the specifications of the R amp TTE Directives 99 5 EC EMC 2004 108 EC LVD 2006 95 EC CE cum MM An Fear e SW EW PROFESSIONAL STATEUROP sistemas automatizados para euro t pa s a Rua do Sobreiro Lugar do Pinheiro Rio C vo S Eug nia Apto 5018 EC Barcelos 4754 908 Rev 1 3 03 12 10 SYOLOW 3d010W 3d010W 3d010WY SlslSlslslsslslsslslesle bl El eH LL OL 6 4TL250 50mAL250 F1 F2 RAIN MONITOR SUN MONITOR RAIN SENS SUN SENSOR WIND SPEED T MOT CODE SENS CODE M4 CODE M3 CODE M2 CODE M1 SE
16. or EXTENDED MENU The manufacturer provides the control unit with only the option of selecting the functions of the main menu If you wish to enable the functions of the extended menu pro ceed as follows press and hold the SET key for 5 seconds the SUN and RAIN LEDs will flash alternately you then have 30 seconds within which to select the functions of the ex tended menu using the SEL and SET keys after another 30 seconds the control unit returns to the main menu LED reference LED off LED on A CODE M1 Step by step Manual P P S Aut E CODE SENS Line Sensor test OFF Line Sensor test O F T MOT Aut shutdown OFF M RAIN ON OFF intermittent Aut shutdown ON A B CODE M1 M2 4 different selectable operating logics Step by step Step by step operation is possible using the radio control and pushbutton control The first impulsive control raises the blind for the motor time The second impulsive control lowers the blind If an impulsive command is sent before the motor stops running the control unit stops the blind another impulsive command re activates the blind in the opposite direction Manual Manual operation is possible using the radio control and pushbutton control The control needs to be constantly en abled to move the blind Releasing the key will always stop operation Venetian blind operation The Venetian blind mode involves manual operation for the first 2 seconds using
17. rain sensor is touched by water The RAIN LED lights up PROGRAMMING KEYS AND INDICATOR LED SEL key this selects the function to be stored The LED flashes to indicate your selection Keep pressing the key to find the required function The selection remains active for 15 seconds during which time the LED keeps flashing after which the control unit then returns to its original state SET key this key programs the function selected with the SEL key Indicator LED LED on stored option LED off option not stored LED flashing option selected LED reference LED off LED on 1 CODE M1 No code Code TX Pgm M1 2 CODE M2 No code Code TX Pgm M2 CODE M3 No code Code TX Pgm M3 CODE SENS No code 6 Motor time 2 min 7 1 CODE M1 Programming the radio control for Motor 1 Programming the 1 or 2 key radio control The radio control transmission codes are programmed as fol lows press the SEL key and M1 CODE LED will start flashing at the same time send the first pre selected code with the re quired radio control M1 CODE LED will start flashing quickly send the second code to be stored M1 CODE LED remains ON and programming will be complete If the second code is not send within 10 seconds the control unit exits the pro gramming phase selecting operation with 1 key of the radio control If all the codes are stored and you try to repeat the programming phase all the indicator LEDs
18. shutter for the configured motor time and the sec 4 R Rain Sensor Input NO ond key Down for lowering controls downward movement 5 GND shared Input of the shutter If another Up command is sent while the shutter 6 W Wind Sensor Input is being raised the control unit continues to raise it whereas if 7 UZ Upward movement Zone Input NO a Down command is sent the control unit stops the motor 8 GND shared Input The procedure is the same for the Down movement phase 9 DZ Downward movement Zone Input NO i 10 UG Upward movement General Input NO Operation using a 3 key radio control BeFree x1 11 GND shared Input Using the BeFree x1 radio control ensures the following opera 12 DG Downward movement General Input NO tion the Up key controls upward movement of the shutter for 13 Antenna Input the configured motor time the Stop key stops operation and 14 Antenna hot pole Input the Down key controls downward movement of the shutter If a Stop command is sent while the shutter is being raised or lowered the control unit stops the motor If a command is sent that is in the opposite direction the control unit causes the shutter to change direction 1 Rev 1 3 03 12 10 Operation using a 3 key radio control MX83 86 Using the MX83 86 radio control ensures the same operation as for the MX81 version The radio control s two side keys and also allow you to select commands Up Stop
19. the same direction before the motor stops run ning the control unit stops the shutter sending a command CONNECTION OF CN1 TERMINAL BOARD for the opposite direction before the motor stops running the ae control unit reverses the movement 1 230V line input Phase 2 230V line input Neutral 1 3 Motor 1 Upward movement output pretation General Keys F 4 Motor 1 Shared output The following type of operation is obtained by connecting the 5 Motor 1 Downward movement output general command buttons normally open for movement acti 6 Motor 2 Upward movement output vation to the low voltage inputs UG DG 7 Motor 2 Shared output UG controls upward movement until the motor running time 8 Motor 2 Downward movement output has elapsed and DG controls downward movement If a com 9 Motor 3 Upward movement output mand is sent in the same direction before the motor running 10 Motor 3 Shared output time has elapsed the control unit will ignore the command if 11 Motor 3 Downward movement output a command is sent in the opposite direction before the motor 12 Motor 4 Up output running time has elapsed the control unit will invert the direc 13 Motor 4 Shared output tion of the motor te Motors Downward movement outpit OPERATION WITH DIFFERENT RADIO CONTROLS It is possible to program different models of radio control stor CONNECTION OF CN2 TERMINAL BOARD ing a code 1 key obtains Step by step cyclical operation Up