Home
RAID Subsystem DVA-08K and DVA-16K
Contents
1. 8 Power On To power on the subsystem 1 Install all the hardware components 2 Make all the connections described above 3 Power on the network connecting devices such as the Ethernet switches 4 Power on the subsystem by turning on both power switches on the rear panel of PSU modules For the location of the power switches please see Figure 7 1 5 Power on servers or host computers 9 Configuring the Host Computer v a a Network The first time you use the subsystem you have to set up your computer to access the sub system To set up the computer 1 Attach a network cable from the DVA s Ethernet port to a network or Connect the computer with the subsystems s Ethernet port via a cross over cable 2 Access any computer on the network NOTICE If you do not use across over cable and connect the unit to a network your network s subnet mask may not allow you to access this IP address without some re configuration 3 To access the subsystem simply access a shell or a DOS prompt on your host computer and enter the following command Windows route add 10 11 12 13 lt workstation IP number gt mask 255 255 255 255 This procedure allows a connection to the subsystem even if your computer has different network settings F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Changing the Configuration viaaWeb Browser en 13
2. 1 Divar 5 CHO OUT 2 RAID subsystem 6 DVA ACON HD50A SCSI cable 3 SCSI port 7 DVA ACON VD680A SCSI cable 4 CHO IN 2 For daisy chaining several subsystems you must switch off the termination of channel CHO 1 OUT of all subsystems except the last Expand the configuration tree gt click Configuration gt Channel gt Channel 0 or Channel 1 gt ID Tab gt Termination Disabled gt Apply 3 Click Configuration gt Configuration Parameters gt System tab gt Reset the Controller gt Apply The subsystem is reset 4 For daisy chaining change the CHO 1 OUT SCSI channel ID of the second subsystem Expand the configuration tree gt click Configuration gt Channel gt Channel 0 or Channel 1 gt Parameters Tab gt for DVA 08K clear the O and 1 check boxes and select the 2 and 3 check boxes gt Apply 5 Click Configuration gt Configuration Parameters gt System tab gt Reset the Controller gt Apply The subsystem is reset 6 Click Configuration gt Host LUN Mapping and change to new ID 7 Switch on the subsystem and then the Divar The power switches of the subsystem are located on the rear side of the unit To configure the Divar Use the control elements on the front panel Bosch Security Systems F 01U 027 800 V1 2006 05 22 en Connecting a Digital Video Recorder RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide After the Divar has booted press ALT The
3. 2 Computer Management Local EB System Tools H E Event Viewer E Shared Folders E 2 Local Users and Groups 53 8 Performance Logs and Alert Device Manager B f Storage EP Removable Storage Disk Defragmenter Disk Management 3 8 Services and Applications o pe File System status Capacity Free Space Free Fault Tob Partition Basic NTFS Healthy System 152 66GB 150 60GB 98 No 80603310902 E Partition Basic CDFS Healthy 17 MB OMB 0 No Convert to Basic Disk Convert to GPT Disk 0603310902 Se mm 17 MB 17 MB CDFS Online health 4 j gt E Unallocated IE Primary partition Bosch Security Systems F 01U 027 800 V1 2006 05 26 en Connecting a Digital Video Recorder RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide 18 Right click the first disk and then click New Volume The system opens the New Volume Wizard dialog box 19 Click Next to open the Select Volume Type dialog box New Yolume Wizard Select Volume Type There are five types of volumes simple spanned striped mirrored and RAID 5 Select the volume you want to create C Simple C Mirrored Spanned C RAID 5 Stined Description A striped volume stores data in stripes on two or more dynamic disks A striped volume gives you faster access to your data than a simple or spanned volume 20 Click Striped and then click Ne
4. 10 10 1 Changing the Configuration via aWeb Browser Changing an IP Address The Bosch RAIDWatch application can be used to change the IP address of the subsystem The Bosch RAIDWatch application is pre installed directly on the subsystems drive and can be accessed with acommon standard browser Alternatively the Bosch RAIDWatch application can be installed on a host PC see Section 11 Using Bosch RAIDWatch on the Host Computer NOTICE If the RAID is deleted or corrupted you need to re install the Bosch RAIDWatch applica tion on the system Rerun the Bosch RAIDWatch setup from your CD select Custom and then click Stand alone on Subsystem The Java Runtime Environment JRE 1 42 or higher is required Using the web interface you have to install the JRE on your PC first The setup for the JRE is on the CD included with the product To change an IP address via a Web browser 1 Open the Web browser 2 Type the unit s IP address in the address bar and then click the Go button A Java Applet is loaded and the Bosch RAIDWatch application starts Connection IP Address 10 11 12 13 Enable SSL O Username Configuration Password Show Root Agent List Cancel Fig 10 1 Logon screen 3 Inthe IP Address box type or select the IP address 4 Select the Enable SSL check box if you want to use the Secure Sockets Layer SSL secu rity option 5 In the Username list click Configuration 6 Int
5. DVA 08K and DVA 16K Quick Installation Guide Connecting a Digital Video Recorder en 25 14 Do not select any check box Click Next to open the Completing the Initialize and Con vert Disk Wizard dialog box 15 Click Finish The system opens the following dialog box with unallocated drive space A Eile Action view Window Help x c 00 2 08 Le Computer Management Local a A System Tools E E Event Viewer E Shared Folders E 2 Local Users and Groups El Performance Logs and Alert a Device Manager E e Storage E Removable Storage Disk Defragmenter Disk Management E E Services and Applications volume tayout Type FileSystem status capacity Freespa StF Partition Basic NTFS Healthy System 152 66GB 150 60 GI Soem_cD_0312 E Partition Basic CDFS Healthy 540 MB OMB 775 84 GB Unallocated 775 84 GB Unallocated 775 84 GB Unallocated gt BB Unallocated Ml Primary partition 16 Right click the first unallocated disk and then click Convert to Dynamic Disk to open the following dialog box Convert to Dynamic Disk ax Select one or more basic disks to convert to dynamic disks Disks Disk 4 Cancel 17 Select the appropriate check boxes of the drives and then click OK to open the following dialog box E Computer Management DATES E Eile Action View Window Help 181 c omenen
6. Quick Installation Guide To configure a VIDOS NVR NOTICE Before you proceed make sure that the VIDOS NVR service is stopped or has not been installed For installing a VIDOS NVR and assigning drives refer to your VIDOS NVR manual The drive letter can only be assigned upon the first installation of the VIDOS NVR The VIDOS NVR setup must rerun if the drive letter has changed 8 Click the Windows Start button and then click Control Panel 9 In Control panel double click Administrative Tools 10 In Administrative Tools double click Computer Management 11 In Computer Management click Disk Management All drives are shown If the subsystem is properly connected the Disk Manager will start the Initialize and Convert Disk Wizard 12 Click Next to open the following dialog box Initialize and Convert Disk Wizard x Select Disks to Initialize You must initialize a disk before Logical Disk Manager can access it Select one or more disks to initialize Y Disk 3 Disk 4 lt Back Cancel 13 Select the appropriate check boxes of the disks you want to initialize and then click Next to open the next dialog box Initialize and Convert Disk Wizard y xi Select Disks to Convert The disks you select will be converted to dynamic disks Select one or more disks to conwert O Disk 4 lt Back Cancel F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem
7. Table 2 2 System settings DVA 08K DVA 16K F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Delivery Status en 7 Menu DVA 08K DVA 16K Drive Check Period Sec 1 Auto Assign Global Spare Drive Enabled SMART Detect Only Spindown Idle Delay Period sec Disabled Drive Delayed Write Enabled Disk I O Timeout Sec 7 SAF TE SES Swap Device Check Period Sec N A Drive Fail Swap Check Period Sec 5 Maximum Tag Count 16 Drive Motor Spin Up N A Configuration Parameters Disk Array Rebuild Priority Normal Write Verify on Normal Access Disabled Write Verify on LD Rebuild Disabled Write Verify on LD Initialization Disabled Maximum Drive Response Timeout ms Disabled AV Optimization Disabled Table 2 2 System settings DVA 08K DVA 16K Bosch Security Systems F 01U 027 800 V1 2006 05 8 en Installation Procedures RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide 3 Installation Procedures To install the subsystem use the following steps Unpack the Subsystem see Section 4 Unpacking the Subsystem Install the system in the rack see Section 5 Rack Mounting Install the Drive Tray see Section 6 Drive Tray Installation Connect the Subsystem Cable see Section 7 Subsystem Cable Connections Power On see Section 8 Power On Configure the Host Computer see Sectio
8. Y Allocation unit size Defaut hd Volume label IN ew Volume IV Perform a quick format lt Back Cancel NOTICE You can use another drive letter instead of F This depends on the VIDOS NVR installation The VIDOS NVR allows to use one drive letter only upon installation 23 Click Format this volume with the following settings and in the File system box click NTFS Click the Perform a quick format check box and then click Next 24 Click Finish The drive is formatted as NTFS 25 Make sure that the drives are available To check the drives open the Windows Explorer and click the drives you assigned before 26 Install VIDOS NVR service or restart the service if already installed 27 To verify the proper installation open the browser type the IP address http lt NVRserver gt status in the address bar and then click GO The browser opens the fol lowing dialog box J VCS VIDOS AVR Service Web Interface Microsoft Internet Explorer Qotei Bosbelen Arkht Emoten Extras 2 gt Owed O e 12 A a ron amp Bregza E hate 109 254 100 206 erate VIDOS NVR Service Web Status Log Recordings Backups Database Config Log Opbons Cos Interface General 10 0001 release build Wed Oct 19 09 3930 2005 Data directory F VIDOS NVR data Performance 50 bytes written Volume Size Free Reserved Available for Free for Data Data LE VIDOS NVR deraliracks R 3 TR 345 TR 177 T
9. four screws in the front side flanges In no instance is a subsystem to be mounted by the front side flanges only as this will result in the deforming of the sub systems chassis causing unacceptably high pressures and or torques to be applied to internal components resulting in various failure modes Equipment racks must be grounded System Integrators should ensure that any integrated storage solution that includes this product has been tested and proved to meet government regulations and codes for sub jects including safety fire and electrical Make sure you have a soft clean surface to place your subsystem before working on it Placing the system on a rough surface during servicing may damage the chassis finish Do not remove any module or component item from its anti static bag until you are ready to install it Pick up and hold modules by their edges or canister Avoid touching PCBs and connector pins Observe all standard ESD prevention methods e g wear an anti static wristband to pre vent static electricity from damaging the electric components The RAID subsystem can be front or rear mounted in a variety of 19 inch wide 48 26 cm racks The slide rail mounting kits are optional Because hard drives are prone to damage due to shock and vibration during operation all equipment should be installed in an equipment rack prior to powering up any subsystems or DVR s in the rack If equipment is added removed or rearranged in an equip
10. not in the Bosch product portfolio and not distributed by Bosch Siemens TC35 WAVECOM Fast Rack M1206 Under Windows 2000 XP 2003 the Java installation program installshield jar only sup ports Netscape 4 5 or above Microsoft Internet Explorer 4 0 or above F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Using Bosch RAIDWatch on the Host Computer en 17 e Windows Messaging MAPI for Windows must be enabled if support for fax or email noti fication under NT is needed Refer to your Windows documentation for more information 5 Windows NetBEUI support for Windows must be enabled if network broadcast support notification is needed Refer to your Windows documentation for more information NOTICE Bosch RAIDWatch allows you to select several options during the installation process How ever it is recommended that all default combinations be retained This installation guide only describes the installation process using the default settings 11 2 Installing Bosch RAIDWatch on a Windows Platform To install Bosch RAIDWatch on your host computer 1 Before you initiate the installation process close any other applications that are currently running This action minimizes the possibility of encountering system errors during setup 2 Insert the Bosch product CD or Bosch RAIDWatch installation CD into the system s CD DVD drive The Bo
11. reset For daisy chaining change the CHO 1 OUT SCSI channel ID of the second subsystem Expand the configuration tree gt click Configuration gt Channel gt Channel 0 or Channel 1 gt Parameters Tab gt for DVA 08K clear the O and 1 check boxes and select the 2 and 3 check boxes for DVA 16K clear the O 1 2 and 3 check boxes and select the 4 5 6 and 8 check boxes gt Apply Click Configuration gt Configuration Parameters gt System tab gt Reset the Controller gt Apply The subsystem resets Click Configuration gt Host LUN Mapping and change to the new ID Switch on the subsystem and then the DiBos The power switches of the subsystem are located on the rear side of the unit To configure the DiBos 8 8 10 11 12 13 14 15 16 17 18 19 20 In DiBos log on as Administrator but do not start the DiBos application Refer to DiBos Installation Manual for more information Click the Windows Start button and then click Control Panel In Control panel double click Administrative Tools In Administrative Tools double click Computer Management In Computer Management click Disk Management All drives are shown Select the drive you want to assign to store video data On the Action menu point to All Tasks and then click Format to open the Format dialog box In the File system box click NTFS and then click OK The drive is formatted as NTFS Make sure that the drives are availa
12. 6 In the Write Policy list click Default 17 Inthe Password box type the password if needed 18 Click Apply NOTICE For Bosch DVRs it is not necessary to create Logical Volumes To add host LUN mapping 19 20 21 22 23 24 25 26 In the navigation tree click Host LUN Mapping Right click the Host LUN Mapping pane and then click Add LUN Map The application opens the Add new LUN to host dialog box In the Channel ID s box select the Channel ID you want to use In the SCSI ID s box select the SCSI ID you want to use In the LUN s box select the LUNs you want to use In the Logical Drive s Volume s for Primary pane select the logical drive In the Logical Drive s Volume s for Primary pane select a partition Click MAP LUN NOTICE In the navigation tree you can check the drive status Click Information and then click Task Under Process To remove a RAID 1 Inthe navigation tree click Configuration and then click Host LUN Mapping 2 Inthe Host LUN Mapping pane select the configured LUN 3 Right click the selected LUN and then click Remove LUN MAP The application opens a dialog box where you accept the changes 4 Click OK The LUN Mapping is no longer listed in the Host LUN Mapping pane 5 Inthe navigation tree click Existing Logical Drive 6 In the Logical Drives pane select the logical drive you want to delete 7 Right click the selected logical drive then clic
13. D and the subsystem will not be secure To lock the flap in place turn the key lock until the groove on its face is in a vertical orientation See Figure 6 3 Fig 6 3 Drive Tray Key Lock Rotation Bosch Security Systems F 01U 027 800 V1 2006 05 10 en Subsystem Cable Connections RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide 7 Subsystem Cable Connections 71 Power Cables 1 Connect the two 2 provided power cables to the power sockets on the back of the sys tem see Figure 7 1 DVA 08K DVA 16K Power Socket Power Socket mn CAZA O Status 7 LED PL Power y Switch CET ES Lo Power Socket Power Switch Power Switch Fig 7 1 Power Supply Module 2 Make sure the power source is within the correct power range 100 to 240 VAC prior to powering on Auto ranging is supported by the power supply modules 3 Plug the other end of power cords into the power source 7 2 Host Channels 1 The subsystem comes with two 2 dual stack VHDCI host connectors on the controller module s faceplate One the In port can be connected to an external host computer or DVR Another the Out port can be used for Daisy Chain to connect another sub system See Figure 7 2 Make sure to use the correct cable for your host computer or DVR see Section 12 Connecting a Digital Video Recorder DVA 08K DVA 16K COM Ports Host amp Cascade ports COM po
14. Divar opens the Main menu 8 9 Inthe Main menu use the arrow key down and move to Disk Manager Then press to open the Disk Manager menu 10 Use the arrow key down and move to STORAGE SETUP Then press to open the Disk Menu with the external drives and their SCSI IDs 11 Use the arrow key down and move to the requested drive Then press 12 Use the arrow key up down and activate YES Then press 13 Assign all drives in this way 14 Press ESC If the drive configuration has changed the Divar opens the Restart Menu 15 To accept the changes and to restart the system use the arrow key left and move to YES Then press NOTICE Alternatively you can use the Divar Control Center Software to change drive configuration Please refer to your Divar manual for more information F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Connecting a Digital Video Recorder en 23 12 3 Connecting a VIDOS NVR To connect a VIDOS NVR 1 Connect a VIDOS NVR with the subsystem You must switch the VIDOS NVR and the sub system off Take care of proper connection and tighten the screws of the plug NOTICE Two and more subsystems Make the SCSI connection after you have changed the SCSI ID of the second and the further subsystems Due to SCSI 3 specifications we do not recommend to daisy chain more than three sub systems cable le
15. IDWatch on the Host Computer 222 eee eee eens 16 11 1 System requirements u kee he a rl ee een 16 11 2 Installing Bosch RAIDWatch on a Windows Platform 0 0 0 0 0c eee eens 17 11 3 Changing Configurations occ ccc 0A ve ccea en ee Pr wend ese baa Alice hod by Pera Bec ted 18 12 Connecting a Digital Video Recorder 2 ee ee ee eee e nes 19 12 1 Connectinga DIBOS 8 ne sen a en a ae Gees Pe nl he 19 12 2 Connecting a Divari ans Kar cca a dd Baca eek oe a 21 12 3 Connecting a VIDOSINVR 333 0a Bee Cea ke eR eee Cede a DREI baa eae N 23 Bosch Security Systems F 01U 027 800 V1 2006 05 4 en Table of Contents RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Precautions en 5 Precautions The system is heavy even without disks installed At least two 2 people will be required to install the subsystem The rack cabinet into which this subsystem will be installed must support overcurrent protection and must not be overloaded by the modules installed Other requirements such as ventilation airflow rack stabilizing features electrical earth and electrical distri bution must comply with the technical specifications listed in the documentation that came with this product All subsystems must be mounted with and supported by the rails provided and secured in position by the
16. R 5 Na TA 21R TR i A Kreis El Otter stat TA iy vcs vinos avr servi 48 VCS VIDOS NR Service er Dt eke 10 28 Make sure that the disks are proper assigned and recording has started You can see it on the status screen Bosch Security Systems F 01U 027 800 V1 2006 05 28 en Connecting a Digital Video Recorder RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide F 01U 027 800 V1 2006 05 Bosch Security Systems Bosch Security Systems Robert Koch Stra e 100 D 85521 Ottobrunn Germany Telefon 49 89 6290 0 Fax 49 89 6290 1020 www bosch securitysystems com Bosch Security Systems 2006
17. RAID Subsystem DVA 08K and DVA 16K DVA 08K DVA 16K BOSCH en Quick Installation Guide RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Table of Contents en 3 Table of Contents 1 PRECAUTIONS cad er etwas See anus Ree neh eva hee RR En ee ae DE RE a ahahaha RER S 5 2 Delivery Status aan ne RS Io he eos ba tae eee 4 6 2 1 RAID Settings a rn ein li ee es a En ES ER En i Sha a eS 6 2 2 System Settings ao tdi ANA IS Ei E A oe Ad Moa ee 6 3 Installation Procedures i e 22 2232 22 a EDDIE eek we Oe ee Sw Vinee CR EE DS 8 4 Unpacking the Subsystem 2 nn eee ene eee nee eee eens 8 5 Rack Mount Sui its Br edad a een iia ea ee Be eee en ase as eda sal Dee 8 6 Drive Tray Installation ace tee are She aL aad a nal ie 9 7 Subsystem Cable Connections osasse eee eia a a a eee e eens 10 7 1 Power Cables a Kar Es a dd E O ea ENG AEEA 10 7 2 Host Channelsies cece ice sree aes ae A A SH RA E AA ee E 10 7 3 COMP OSs att re a a ee Le er Cree Macs 11 7 4 RJ 45 Ethernet PO Ein ee ae ae sr den eh eee den ga Se e E 11 8 Power One A ees ded Ava Pat Na het ae Gam og oe eet eek 12 9 Configuring the Host Computer via a Network 0 0 nee teens 12 10 Changing the Configuration via a Web Browser 0 cc eee ee ee ee ee ee ee eens 13 10 1 Changing an IP Address mimica cit 2 ea ee ee ern a re de 13 10 2 Guidelines for Setting Up a RAID co on ouun eee eens 14 11 Using Bosch RA
18. ately On the Action menu click Configuration and then click Create Logical Drive Click the physical drives from the Front View pane that are used in the Logical Drive The Selected Members pane displays the disk drives slot IDs and sizes In the RAID Level list click a raid level In the Stripe Size list click a stripe size We recommend using a stripe size of 16k In the Initialization list click On line if the storage should be available immediately for the host Or click Off line if the storage should be available after initialization is finished In the Write Policy list click Default Click OK The application opens a dialog box where you accept the changes Click OK to create a logical drive To add partitions 10 11 12 13 14 In the navigation tree click Existing Logical Drive In the Logical Drives pane select the logical drive you want to partition Right click the selected logical drive and then click Edit Partition The application opens the Edit Partition dialog box Right click the partition bar and then click Add Partition The application opens the Par tition Size dialog box Type the desired capacity and then click OK Some DVRs only support a maximum capac ity of 2 TB F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Changing the Configuration via a Web Browser en 15 15 Close the Edit Partition dialog box 1
19. be a Pentium or above PC compatible running Windows 2000 XP and Windows 2003 that supports Java Runtime 1 4 2 or higher 256 color or higher mode management station monitor At least one available RS 232C port is required if connection to the controller is through the RS 232C Local Client Running Bosch RAIDWatch Manager Computer must be Pentium or above PC compatible running Windows 2000 XP and Win dows 2003 32 bit or 64 bit that supports Java Runtime 1 4 2 or higher Remote station must be running Netscape 4 7X Internet Explorer 6 0 or Mozilla 5 0 and Java Runtime 1 4 2 for a particular platform 256 color or higher mode management station monitor At least one available RS 232C port is required if connection to the controller is through the RS 232C Windows Messaging MAPI for Windows 2000 XP 2003 if fax notification support is needed Windows NetBEUI support for Windows 2000 XP 2003 must be enabled if network broadcast support notification is needed Please refer to your Windows documentation for more information SNMP traps service for Windows if SNMP traps notification is desired TCP IP with a valid IP assigned to each controller subsystem A fax modem that supports Hayes AT command protocol is required if using the fax event notification function Fax command class 2 0 and above A GSM modem is required if using the SMS short message event notification function Bosch RAIDWatch currently supports two GSM modem models
20. ble To check the availability open the Windows Explorer and click the drives you assigned before On the Start menu point to All Programs and then click DiBos DiBos Explorer opens In the System menu click Configuration to open DiBos configuration In the navigation tree click Drives and select the drives that store the video data Click Save F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Connecting a Digital Video Recorder en 21 12 2 Connecting a Divar The following hardware is required to connect a Divar To connect a Divar with the first subsystem you need the DVA ACON HD50A SCSI cable To expand an existing system Divar and subsystem with an additional subsystem you must order the DVA ACON VD680A 0 5 m 20 in SCSI cable To connect the Divar 1 Connect the Divar with the subsystem You must switch the Divar and the subsystem off Take care of proper connection and tighten the screws of the plug NOTICE Two subsystems Make the SCSI connection after you have changed the SCSI ID of the second subsystem Due to SCSI specifications do not daisy chain more than two subsystems CAUTION The internal disks of a Divar must be disabled when using a disk array in RAID mode Oth erwise if the internal disk of Divar fails all data is lost even on the subsystem OJO Fig 12 2 Connecting Divar
21. cable If you want to expand an existing system DiBos and subsystem with an additional sub system Order the DVA ACON VD680A cable 0 5 m 20 in or DVA ACON VD68A cable 1 m 40 in To connect the DiBos 8 1 Connect DiBos 8 with the subsystem Note switch the DiBos 8 and subsystem off Take care of proper connection and tighten the screws of the plug NOTICE Two and more subsystems Make the SCSI connection after you have changed the SCSI ID of the second and the further subsystems Due to SCSI 3 specifications we do not recommend to daisy chain more than three sub systems cable length maximum 12 m 39 4 ft O OJO A UNSER Fig 12 1 Connecting DiBos 8 DiBos 5 CHO OUT 2 RAID subsystem s 6 DVA ACON HD68A or cable supplied with DiBos 3 SCSI port 7 DVA ACON VD68A or 4 CHO IN DVA ACON VD680A SCSI connection 2 For daisy chaining several subsystems you must switch off the termination of channel CHO 1 OUT of all subsystems except the last Bosch Security Systems F 01U 027 800 V1 2006 05 20 en Connecting a Digital Video Recorder RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Expand the configuration tree gt click Configuration gt Channel gt Channel 0 or Channel 1 gt ID Tab gt Termination Disabled gt Apply Click Configuration gt Configuration Parameters gt System tab gt Reset the Controller gt Apply The subsystem is
22. cessful 7 Click Finish to complete the process and exit the installation menu Bosch RAIDWatch is installed on your host computer 11 3 Changing Configuration After installing Bosch RAIDWatch on your host computer you can change the configuration To change configuration 1 Click the Windows Start button point to All Programs point to Bosch and then click Bosch RAIDWatch The screen displays the log on dialog box 2 Change the configuration See Section 10 1 Changing an IP Address and Section 10 2 Guidelines for Setting Up a RAID F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Connecting a Digital Video Recorder en 19 12 12 1 Connecting a Digital Video Recorder These instructions explain how to connect to the following Digital Video Recorders DVR DiBos 8 e Divar e VIDOS NVR Connecting a DiBos 8 The following hardware is required to connect a DiBos If you have not ordered a DiBos 8 Include DB EK 021 in your order The DiBos 8 is delivered with an pre installed SCSI host bus adapter and a 3 m 10 ft SCSI cable If you already have a DiBos 8 but without a SCSI host bus adapter You must order DB EK 061 The upgrade kit includes a SCSI host bus adapter and a 3 m 10 ft SCSI cable for field upgrade If you already have a DiBos 8 with installed host bus adapter but no SCSI cable is avail able Order the DVA ACON HD68A
23. he Password box type the password if needed factory default no password 7 Click OK The computer opens the Bosch RAIDWatch application Bosch Security Systems F 01U 027 800 V1 2006 05 14 en Changing the Configuration via a Web Browser RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Fig 10 2 Bosch RAIDWatch application 8 In the navigation tree click Configuration and then click Configuration Parameters 9 Inthe Configuration Parameters pane click the Communication tab 10 In the IP Address box type the new IP address 11 In the Subnet Mask box type the new subnet mask 12 Click Apply to open a dialog box where you accept the changes 13 Click OK NOTICE For security reasons we also recommend changing the passwords of the access levels for Con figuration and Maintenance In the Configuration Parameters pane click the Password tab and then change the passwords accordingly The password for the access level Information is 1234 default and cannot be changed 10 2 Guidelines for Setting Up a RAID To change the factory default settings and the optional settings use the following procedure To create a logical drive 1 7 8 9 Click the Windows Start button point to All Programs point to Bosch and then click Bosch RAIDWatch The screen opens the log on dialog box In the navigation tree click Configuration and then click Create Logical Drive Altern
24. k Delete Logical Drive The application opens a dialog box where you can accept the changes 8 Click OK The Logical Drive is no longer listed in the Logical Drives pane NOTICE For more information see Bosch RAIDWatch user manual Bosch Security Systems F 01U 027 800 V1 2006 05 16 en Using Bosch RAIDWatch on the Host Computer RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide 11 Using Bosch RAIDWatch on the Host Computer Bosch RAIDWatch allows you to administrate multiple subsystems from your host computer We recommend the installation on a host computer if central management of multiple sub systems is required 11 1 System requirements Before starting the installation read through the notes listed below TCP IP must be installed and running with a valid IP address assigned to a server The server can either be used as a centralized management station a remote client using a browser to access the array or directly attached with a RAID subsystem using the in band protocols Your system display must be running in 256 colors or a higher mode otherwise some con figuration items may not be visible Screen size of 1024 x 768 is recommended to avoid any graphic transformation Check to confirm that the RAID disk arrays and controllers are installed properly For the installation procedure see the documentation included with the controller subsystems Server Running Bosch RAIDWatch Computer must
25. ment rack DVR s and subsystems should be power down prior to this work All disks should be removed from the subsystem prior to assembly in a rack Only after all equipment is installed in a rack should the disks be installed reinstalled Hard drives must always be grasped on the drive carrier surfaces and not by the drive sur faces it is most critical to avoid contact with the printed circuit board or rear connec tors Contacting the hard drive on the connector or PCB may result in ESD damage which will yield various immediate or latent failures Drives must not be stacked on top of each other without their protective clamshells Due to the magnetic components within drives stacking them directly on top of each other can result in erasing the programmable ICs When replacing components insert them as gently as possible while assuring full engage ment Vibration or shock can damage hard drives in the affected unit or other units in the rack Hard drives are very sensitive to shock and vibration especially while in operation and should always be handled very carefully After all equipment is installed in a rack dress the power and data cables such that power cables are not resting against data SCSI IP RS232 cables Bosch Security Systems F 01U 027 800 V1 2006 05 6 en Delivery Status RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide 2 1 2 2 Delivery Status The subsystems are shipped with drives p
26. n 9 Configuring the Host Computer via a Network Change the IP Address see Section 10 1 Changing an IP Address Change the factory default settings see Section 10 2 Guidelines for Setting Up a RAID Connect the DVR see Section 12 Connecting a Digital Video Recorder 2 0 AB 7 4 Unpacking the Subsystem Check the included Unpacking Checklist and verify the model name and shipping contents against the checklist 5 Rack Mounting Slide rails are required for rack mounting For rack mounting use only one of the following slide rail kits DVA 08E and DVA 08K DVA 16K Slide rails for 533 mm to DVA ASRK 28A 724 mm deep racks 21 to 28 5 Slide rails for 647 mm to DVA ASRK 36A 914 mm deep racks 25 5 to 36 Slide rails for 610 mm to DVA ASK 32A 813 mm deep rack 24 to 32 Slide rails for 660 mm to DVA ASK 35A 914 mm deep rack 26 to 36 Table 5 1 Slide rail kits NOTICE Refer to Slide Rail Kit Installation Manual for detailed information F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Drive Tray Installation en 9 Drive Tray Installation The Bosch DVA subsystem is delivered with pre configured burned in drives The drives are packed in separate boxes The drives can be installed in any order CAUTION For expansion or replacement use Bosch drives only Order DVA ADTK 050A drive tray with moun
27. ngth maximum 12 m 39 4 ft O Fig 12 3 Connecting VIDOS NVR 1 VIDOS NVR 5 CHO OUT 2 RAID subsystem 6 DVA ACON VD68A or 3 SCSI port DVA ACON VD680A 4 CHO IN 2 For daisy chaining several subsystems you must switch off the termination of channel CHO 1 OUT of all subsystems except the last Expand the configuration tree gt click Configuration gt Channel gt Channel 0 or Channel 1 gt ID Tab gt Termination Disabled gt Apply 3 Click Configuration gt Configuration Parameters gt System tab gt Reset the Controller gt Apply The subsystem is reset 4 For daisy chaining change the CHO 1 OUT SCSI channel ID of the second subsystem Expand the configuration tree gt click Configuration gt Channel gt Channel 0 or Channel 1 gt Parameters Tab gt for DVA 08K clear the O and 1 check boxes and select the 2 and 3 check boxes for DVA 16K clear the 0 1 2 and 3 check boxes and select the 4 5 6 and 8 check boxes gt Apply 5 Click Configuration gt Configuration Parameters gt System tab gt Reset the Controller gt Apply The subsystem is reset 6 Click Configuration gt Host LUN Mapping and change to new ID 7 Switch on the subsystem and then the VIDOS NVR The power switches of the subsystem are located on the rear side of the unit Bosch Security Systems F 01U 027 800 V1 2006 05 24 en Connecting a Digital Video Recorder RAID Subsystem DVA 08K and DVA 16K
28. re configured for RAID 5 The configuration is suit able for the most configurations The factory default settings are shown below RAID Settings DVA 08K DVA 16K Number HDD 4 8 16 RAID RAID 5 RAID 5 RAID 5 Spare no no no Stripe Size 16 16 16 Partitions 1 2 4 Size of Partition est 1 5 TB 50 1 7 TB 25 1 875 TB Assigned Disk Space 470000 MB 470000 MB 470000 MB SCSI Channel 0 0 0 SCSI IDs 0 0 1 0 1 2 3 LUN 0 0 0 0 0 0 O Table 2 1 Factory Default settings DVA O8K DVA 16K System Settings Menu DVA 08K DVA 16K Configuration Parameters Communication LAN O Static IP Address IP Address 10 11 12 13 Subnet 255 0 0 0 Configuration Parameters Controller Write Back Cache Enabled Optimization Sequential I O Sync Period Sec Disabled SDRAM ECC Enabled Configuration Parameters Host Side Maximum Queued I O Count 256 LUNs per Host SCSI ID 1 Maximum Concurrent Host LUN Connection Default 4 Tags Reserved per Host LUN Connection Default 32 Peripheral Device Type Default 7F no device present Peripheral Device Qualifier Default Connected Device Supports Removable Media Default Disable LUN Applicability All Undefined LUNs Cylinder Head Sector Default Variable Variable Variable Configuration Parameters Drive Side Disk Access Delay Time Sec 25
29. rt Ethernet port 20 04 O Y g a n H Ethernet Port SCSI Connectors LED Indicators Fig 7 2 Controller Module 2 Attach the VHDCI SCSI connector to the subsystem and attach the other end to the host computer or DVR Note that the subsystem comes with a firmware terminator and requires no additional terminators on the subsystem side 3 If two subsystems are cascaded disable the firmware terminator setting on the sub system which is connected in between the host and another subsystem see Section 12 Connecting a Digital Video Recorder F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Subsystem Cable Connections en 11 7 3 COM Ports The DVA 08K comes with one 1 COM port and the DVA 16K with two 2 COM ports The COM1 port is reserved for terminal emulation management This port can be used to access firmware s embedded configuration utility One 1 audio jack to DB9 cable and a null modem are provided to facilitate the connection of the COM1 port See Figure 7 2 The COM2 port of DVA 16K is reserved Do not use 7 4 RJ 45 Ethernet Port A shielded Ethernet cable can be used to connect the RJ 45 Ethernet port to a hub on a net work enabling you to manage your subsystem via the network See Figure 7 2 Bosch Security Systems F 01U 027 800 V1 2006 05 12 en Power On RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide
30. sch RAIDWatch installer program is included on the CD ROM that came with your subsystem An auto run screen provides a hot link to the installer program See Figure 11 1 RAIDWatch o Install RAIDWatch RAIDWatch Manual E BOSCH Fig 11 1 Product Utility CD Initial Screen 3 Select the Bosch RAIDWatch check box and then click Install RAIDWatch The computer launches the installation procedure and opens a welcome screen 4 To install Bosch RAIDWatch click Next The application opens the License Agreement dialog box 5 Click Accept If you agree with the specified terms The application opens a new dialog box with two installation options 6 Click Typical Selecting this option default allows you to install the Bosch RAIDWatch software RAID agent and necessary drivers on the host computer The installation pro cedures described in this Quick Installation Guide are based on this selection Click Browse and select a different directory or create a new directory Then click Next Bosch Security Systems F 01U 027 800 V1 2006 05 18 en Using Bosch RAIDWatch on the Host Computer RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide NOTICE Please refer to the Bosch RAIDWatch User s Manual for details on the Custom option The installer program starts copying the application files to your system You receive a successful installation message if the software installation procedure is suc
31. ted hard disk Handle hard drives with extreme care Hard drives are very delicate Dropping a drive onto a hard surface even from a short distance and hitting or touching the circuits on the drives with your tools may cause damage to the drives Insert drive trays as gently as possible Observe all ESD prevention methods when installing drives Only use screws supplied with the drive canisters Longer screws may damage the drive To install a drive tray 1 Turn the key lock to the unlocked position The key lock is unlocked if the groove on its face is in a horizontal orientation See Figure 6 1 nr Key lock E Re t E Front Button LED Indicators Fig 6 1 Drive Canister Front View 2 Open the front flap on the drive tray by pushing the button on the front of the drive tray The button is easy to access See Figure 6 2 Fig 6 2 Opening Drive Tray Front Flap 3 Line the drive tray up with the slot in which you wish to insert it Make sure that it is rest ing on the rails inside the enclosure Once the drive tray is lined up with the slot gently slide it in This action should be done smoothly and gently 4 Close the front flap on the drive tray Make sure the front flap is closed properly to ensure that the SATA connector at the back of the drive tray is firmly connected to the corresponding connector on the mid plane board If the front flap is not closed properly then the connection between the HD
32. xt New Yolume Wizard Select Disks You can select the disks and set the disk size for this volume Select the dynamic disks you want to use and then click Add Available Selected Disk 3 734464 MB lt Bemove pika 734464Me lt Remove All Total volume size in megabytes MB Maximum available space in MB 794464 Select the amount of space in MB 794464 a 2383392 lt Back Next gt Cancel 21 Select your previous converted disk and then click Next NOTICE If you use disks with different sizes the size of the smallest disk will be used New Yolume Wizard Assign Drive Letter or Path For easier access you can assign a drive letter or drive path to your volume Assign the following drive letter F Mount in the following empty NTFS folder C Do not assign a drive letter or drive path F 01U 027 800 V1 2006 05 Bosch Security Systems RAID Subsystem DVA 08K and DVA 16K Quick Installation Guide Connecting a Digital Video Recorder en 27 22 Click Assign the following drive letter click F to assign this letter to the selected drive and then click Next New Volume Wizard x Format Volume To store data on this volume you must format it first Choose whether you want to format this volume and if so what settings you want to use Do not format this volume Format this volume with the following settings Eile system NTFS
Download Pdf Manuals
Related Search
Related Contents
DVR User Manual - Watcher Total Protection MOTA Battery Stick PR Chameleon User Manual Tucano Luce Buffalo 125Mbps High Speed Mode Wireless Cardbus Adapter with AOSS Copyright © All rights reserved.
Failed to retrieve file