Thermocouple Process Calibrator User`s MANUAL
Contents
1.
2. Thermocouple Process Calibrator User s MANUAL Thermocouple Process Calibrator Manual Safety Information To avoid possible electric shock or personal injury Never apply more than 30V between any two jacks or between any jack and earth ground Make sure the battery door is closed and latched before you operate the calibrator Remove test leads from the calibrator before you open the battery door Do not operate calibrator if it is damaged Do not operate the calibrator around explosive gas vapor or dust To avoid possible damage the calibrator Make sure choose the right jack and rang before use the calibrator to measurement or calibrator Take away the calibrator from the used circumstance before operate the calibrator or after close the calibrator Thermocouple Process Calibrator Manual Introduction Thermocouple Process Calibrator is a exactitude measurement and source handhold instrument it can be use to calibrate the Thermocouple instrument Thermocouple Process Calibrator can measure or simulate 8 types of difference Thermocouple C orF and measure or simulate the millivolt But it could not use to measurement or source at a same time The accessories 2 pcs Thermocouple plugs no wire 6 AAA 1 5V battery user s manual If the Calibrator is broken or short of some accessories please contact the supplier The following table has showed the technical parameter and function of the Calibrator Th
3. ermocouple Process Calibrator Manual e e Specification All the specification will under 1 year calibration cycle and temperature between 18 28 C except addition explain Measure input Simulate output Millivolt specification INPUT OUTPUT RANGE RESOLUTION ACCURACY 10mV 75mV 0 01mV 0 025 2counts Maximal input voltage 30Vpp Thermocouple Process Calibrator Manual Measure input Simulate output Thermocouple Specification REFERENCE FUNCTION RESOLUTION ACCURACY JUNCTION ERROR J TYPE 200 1200 C 328 2192 F X 0 3 C 10uV K TYPE 200 1370 C 328 2498 F X 0 3 C 10uV Thermocouple Process Calibrator Manual N TYPE 250 1300 C 418 2372F 0 1 C F X 0 3 C 10uV Maximal input voltage 30Vpp General Specifications Maximum voltage applied between any jack and earth ground or between any two jack 30V Storage temperature 40 C 60 C Operating temperature 0 C 50 C Operating altitude 3000 meters maximum Temperature coefficient 0 02 C on 0 C 18 C and 28 C 50 C Relative humidity 95 up to 30 C 75 up to 40 C 45 up to 50 C Shock Random 2g 5Hz to 500Hz Safety 1 meter drop test Thermocouple Process Calibrator Manual Power requirements 6 x AAA 1 5V Battery Size 205mmx98mmx46mm Weight 472 g include battery International Symbols Meaning Earth ground Conforms to European Union directives Refer to this instruction sheet for information about t
4. his feature Battery Thermocouple Process Calibrator Manual Explanation on Front Panel The front panel is show as in right figure 13 1 Input jack 11 4 2 2 Output jack be 3 Power key 14 15 4 Mode key 46 5 C F key 6 input output key 3 7 Increase more value key pee 8 Reduce more value key T x 9 Increase less value key g 10 Reduce less value key O 5 70 8 d 11 12 13 14 15 16 Operation Instructions Thermocouple Process Calibrator Manual Low power indication Input state indication Output state indication Reading value Unit indication Mode indication Thermocouple or Millivolt measurement input DPress the power key3 turn on the calibrator Press the Input output key When on the input mode S Press mode key on the measure type you want Put the measure thermocouple or millivolt source into the input jack Get the reading valuel 4 INPUT DIE CLI LILLI TYPE K INPUT ies E 1 TERMINAL 30V MAX TC Thermocouple Process Calibrator Manual The number in the LI referring to the Explanation on Front Panel Page7 Thermocouple or Millivolt Simulate output OUTPUT DPress the po
5. wer key3 turn on the calibrator NJ Press the Input output key When on the output mode S Press mode key on the measure type you want n n n n C Press the adjust value key 7 8 9 10 to let the value LI LI LI LI a B on your need OY Put the thermocouple instrument or voltage meter into TYPE J the output jack2 ON amp f you want to change the output value then press the adjust value key7 8 9 110 or change to other thermocouple type use the mode key a fe TERMINAL 30V MAX L TC Thermocouple Process Calibrator Manual The number in the referring to the Explanation on Front Panel Page7 Maintenance Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents Calibration Calibrate your calibrator once a year to ensure that it performs according to its specifications Replacing the Battery Please change the battery when the LCD indicates Es Turn off the power of the Calibrator When you change the battery and screw off the breechblock on the battery cabinet cover then take off it and instead the fresh AAA 1 5V battery Connect wire Use the accessories thermocouple plug to make the difference plug connect wire which you want 10 Thermocouple Process Calibrator Manual 11
Download Pdf Manuals
Related Search
Related Contents
User Guide Sencor SWK 1791WH electrical kettle RCA RP-7900A User's Manual Guia do usuário Bedienungsanleitung TIBCO Spotfire® Clinical 4.0.1 User`s Manual Emerson ITONE IP100BKC User's Manual Copyright © All rights reserved.
Failed to retrieve file