1. AlcoScan AL3100 USER S MANUAL BAC Status Display Mouthpiece Slot Power Button Ready Indicator Uses Disposable Straw Mouthpieces The rear pane of the AL3100 features a Case Hatch Lock Power a i D i LED Range Indicator Port Fan and Serial Port for Printer Connection The AlcoScan AL3100 is a table top wall powered breathalyzer that measures a breath sample to detect alcohol in the lungs The reading is converted to blood alcohol concentration BAC gt The AlcoScan AL3100 uses an advanced semiconductor sensor to detect alcohol The AL3100 uses Pre Calibrated Replaceable Sensor Modules to eliminate the need for calibration The sensor module should be replaced approximately once every 500 tests The AL3100 also features an optional detachable printer unit so that the time date result and name field can be recorded on readout Operating Instructions Le 10 Make sure the AL3100 is plugged into a power source using a cable from the power port If you are also using a printer make sure the printer is attached the AL3100 using BOTH the power cable to draw power from the AL3100 as well as the serial cable to provide an operating interface to allow the printer to access results Press the Power Button to turn the device on You will see a countdown in the display The sensor is warming up to the proper temperature At the end of the countdown the Ready Indicator
2. gh frequency of positives many high BAC readings can shorten the duration before replacement is required The unit requires a sufficient air sample to process an accurate reading The user must blow firmly and steadily into the mouthpiece The breathalyzer unit contains a sensitive oxide semiconductor alcohol sensor that is continuously exposed to the environment The sensor may degrade faster than normal if used in a poorly ventilated area The semiconductor sensor can be damaged upon contact with silicon rubber volatile chemicals and chlorine based chemicals Prevent exposure of the sensor to the such items Although the unit is designed to minimize the casual intake of some moisture excessive liquid flow i e excess saliva liquid alcohol from the mouth can damage the sensor or render the sensor immediately inaccurate Extremely high BAC readings can sometimes affect the following test due to the residual high concentration breath sample from the previous test Upon discovery of a high BAC reading please wait at least 10 minutes before performing the next test Environmental conditions can cause the unit to be unable to reset and stabilize the sensor for the next test If this occurs please move it to a cleaner location free of excess dust smoke and chemical vapors Warranty The manufacturer warrants the product to be free from defects in workmanship or material excluding calibration under normal use for one 1 yea
3. nveniently ordered and replaced eliminating the need for traditional recalibration service 12 Auto Power Off AL3100 features an Auto power off function when inactive for 15 minutes 13 Package AL3100 Unit 1x AL3100 Breathalyzer Unit 1x AL3100M Replaceable Sensor Module 1 x MA6000 Mouthpiece Adapter 1 x AL3100 Power Adapter Printer for AL3100 Optional 1x Printer Unit 1 x AL3100 to Printer Power Cable 1 x AL3100 to Printer Serial Cable AL3100M Sensor Module Replacement Instructions 1 2 3 ONAUA 9 1 Disconnect the AC power adapter from the AL3100 Unit Unlock and open the rear hatch door Carefully remove the sensor module from behind the breath channel Make a note of position and configuration so that you can replace the new module to the same location Carefully disconnect the connector wire from the sensor module The old sensor module may be discarded Connect the new sensor module to the connector wire Place the sensor module back behind the breath channel in its original position Make sure the sensor module is securely mounted behind the breath channel to prevent it from slipping out of the hole Close the hatch door 0 The power adapter may now be reconnected and the device can be used normally Warnings 1 Sensor modules must be replaced approximately every 300 500 tests according to the procedure provided above to ensure continuous accuracy of the AL3100 A hi
4. r from the date of purchase The manufacturer s obligation under this warranty is limited to replacing adjusting or repairing the unit if returned along with proof of purchase This warranty is void if the unit has been tampered with or maliciously damaged The replacement of sensor modules is a periodic maintenance procedure required of this device in order to maintain accuracy and as such is not a warranty service Technical Support For technical support please contact us using the information below AK Solutions USA LLC 21 Grand Ave Suite 102 Palisades Park NJ 07650 Toll Free 800 943 1016 Monday Friday 9AM to 6PM EST Tel 201 943 9411 Monday Friday 9AM to 6PM EST Fax 201 943 8828 Email support alcomate net Web http www alcomate net Technical Support For technical support please contact us using the information below AK GlobalTech Corp 21 Grand Ave Suite 102 Palisades Park NJ 07650 Toll Free 800 943 1016 M F 9AM to 6PM EST Office 201 943 9411 M F 9AM to 6PM EST Fax 201 943 8828 Email support akglobaltech com Web http AKGlobalTech com
5. t Mouthpiece Slot e Includes mouthpiece adapter for disposable mouthpiece use e Detachable for cleaning purposes Case Hatch Lock Allows access to inner chamber of device Fan Circulates air to refresh sensor e Spins up before the test and after the test to refresh the air around the sensor thereby extending sensor life Power adapter port e Use AC adapter to DC 12V adapter to power the AL3100 Printer Power port e The printer draws power from the AL3100 Both the printer power cable and the serial cable must be attached to use the printer Serial Port e Connect the printer to the AL3100 for operation using a serial cable Both the printer power cable and the serial cable must be attached to use the printer Technical Specifications 1 Sensor Type Semiconductor Alcohol Sensor 2 Product dimensions in mm AL3100 240 x 130 x 260 Printer 119 x 89 x 130 3 Weight 4 5 kg 4 Operating Temperature Range 20 Celsius 50 Celsius 5 Breath Sampling Time 3 4 Second Breath Sample 6 Breath Analyzing Time 2 Seconds 7 Result Output Format BAC Percent Blood Alcohol Concentration 8 Measurement Range 0 00 0 40 BAC 9 Error Range 0 01 at 0 05 BAC DOT format accuracy 10 Power AL3100 AC 220V Adapter Output DC 12V Printer The printer draws power from the AL3100 11 Maintenance The AL3100 features Pre Calibrated Replaceable Sensor Modules to minimize maintenance The sensor module can be co
6. will light up The device is ready to accept a breath sample Attach a mouthpiece to the mouthpiece adapter covering the mouthpiece slot As the user begins to blow into the device an audible countdown will start from 3 and end at 0 Important The user must continue to blow until this countdown is complete The device will analyze the breath sample for a few seconds After analysis the result will be shown in the display for 10 seconds in the form of a BAC reading An accompanying LED indicator will also light up showing whether the reading is in high moderate or low ranges If the optional printer is attached the result will also be printed showing date time BAC reading and name field the name must be written by hand directly onto the printout Product Details Results Display Displays Analyzed BAC Status Display e Countdown to calibration When device is powered there is a countdown to set the sensor to the correct temperature e Ready to test Displays 0 after countdown is complete e Breath sampling Displays 3 2 1 O to indicate seconds left of breath sampling time The user should continue to blow until 0 is heard LED Range Indicator Green The detected BAC is less than 0 02 LED Range Indicator Yellow The detected BAC is between 0 02 and 0 05 LED Range Indicator Red The detected BAC is greater than 0 05 Ready Indicator Light Indicates that the unit is ready to tes