1. NGFTB Block Type 1 Isc Adapter Type FC Singlemode EN LC Block Orientation EB Ee BABA L SC angled polish Block Capacity EM Left 2 FC ultra polish B 72 BM Right K LC ultra polish C 96 Cable Exit Direction 144 or 192 only M 144 U Upward M LC angled polish Q 192 LC only D Downward oa M Multimode 50 125 um Aqua T SC 1 192 and 144 blocks using block type 1 or 2 cannot C LC 144 or 192 only be used in legacy 26 wide NGF frames Due to space limitations do not use Tracerlight patch cords in the 192 block Other configurations are available upon request Please contact ADC Technical Assistance Center www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Adapter Only Fiber Termination Blocks Conversion Kits Cable Clamping Kit and Block Conversion Kit Adapter only blocks ordered from page 16 are configured to accommodate single fiber jumpers or multifiber breakout cables Additional hardware is required if loading a preterminated intrafacility cable IFC or OSP cable Block conversion kits are available to convert adapter only blocks to blocks that will accept preterminated IFC or OSP style cables The conversion kits contain the cable management hardware brackets and cable clamps required to olaaa convert the block The kit required will depend fo
2. Block Orientation a Number of Pigtail Assemblies 08 Used with 96 position block 12 Used with 144 position block 16 Used with 192 position block L Left R Right Front Connector and Adapter Type Singlemode SC ultra polish SC angled polish FC ultra polish LC ultra polish 144 or 192 only LC angled polish 144 or 192 only ultimode 50 125 um Aqua SC LC 144 or 192 only For multimode cable options refer to literature 103472AE Pigtail Type 1 50 125 um OM3 LOMMF3 5 Singlemode 1192 and144 blocks cannot be used in legacy 26 wide NGF frames Due to space limitations do not use Tracerlight patch cords in the 192 block LOMMF Laser optimized multimode fiber For multimode cable options refer to the TrueNet Solutions literature 102094AE Other configurations are available upon request Please contact ADC Technical Assistance Center For underfloor applications an FOTSB pg 24 must be used www te com adc 1 952 938 8080 1 800 366 3891 High Density Frame Solutions NGF Optical Distribution Frame Adapter Only Fiber Termination Blocks Fiber termination blocks FTBs without fiber can be ordered fully loaded with adapters Before ordering determine the block orientation and cable exit direction Adapter only FTBs may be ordered with a left ori
3. Di pI KEY L Routing is Down The Inside Back of the Fiber FOTSB Fiber Optic Terminal Block Terminal Storage Bay DDODDOD DOOD o ofa ow T x FIBER TERMINAL D CD CD Q9 D D OD D D OO CO Xp GOD FTB Fiber BLOCK DETAIL Terminal Block CA IFC Intrafacility Fiber Cable FOTSB NGF FRAME FOTSB NOTE Equipment Jumpers Should be Populated from the Bottom Block Position Up and The OSP Blocks Should T Right be Deployed From The Top Block Position Down Vertical Vertical Routing Multi Fiber Cable amp Fiber Patch Cords Together Into NGF Vertical TIS d Eel High Density Frame Solutions IFC Cable EQU Jumper to FTB Rear Cross connect Jumper EQTJumper to FTB Front KEY OSP OSP Pre term Block MVAM FRT amp RR Access Microvam FGS Fiberguide System NGF Next Generation Frame FTB Fiber Term Block FOTSB F O Terminal Storage Bay EG End Guard MVAM Microvam 5 00 e 30 00 12 00 E 19 00 Side View Shown W EG Removed 52 00 Front View LI L j l MVAM y i EG OSP FTB FOTSB EG Front
4. Grounding Kit 305 mm 12 NGF ACCEXT 12 30 NGF ACCEXTSLM12 610 mm 24 NGF ACCEXT24 30 NGF ACCEXT24 SR 1 4 m 54 NGF ACCEXT54 30 NGF ACCEXT54 SR The fiber distribution frame is equipped with a grounding kit designed with mechanical fittings including clamps straps and connectors Order this kit only if you are building a frame using your own frame When connecting frame ground to office ground conductor an H TAP bonding kit should also be ordered Grounding kit includes H TAP bonding kit includes 2 hole terminal lug 1 each H TAP 1 each 6 AWG copper tinned wire 5 H TAP insulated cover 1 each Wire clips 8 each 2 hole terminal lug crimp 3 each 312 24 x 1 2 screws 10 each Terminal lug screw 4 each 6 AWG stranded insulated wire 2 Star washer No ox grease Ordering Information 6 each 1 tube Description Catalog Number Grounding kit E 501 L37 H TAP bonding kit E 501 L166 Included with all NGF frames AC Outlet Kit The AC outlet kit provides the hardware for mounting AC power outlets on the frame Each kit includes a prewired AC power outlet strip that mounts at the bottom of the frame Ordering Information Description Catalog Number Dual outlet mounts in base of NGF ACOK 2 AC outlet cover kit RAC 0X0493 1 952 938 8080 www te com adc 1 800 366 3891 High Density Frame Solutions NGF Optical Distribution Frame Frame Accessories
5. Side Vi 40 00 Shown We ad Front View ei LIL EG OSP SPLTR EG Front Facing NGF PON Splitter Block Application S N aN N S H H D It laa 8 8 8 8 FGS T S T Ho FOF O FOF O O HO O HO O O A 0 E O A 0 E O O lol O lol O LOR HOE O Q C Q ol 0 O HOH O TOL O m 84 00 L vI L i ji L i O Lol O Lol O j O OB O OB O O 0 10 O E O Ok WO O O 0 o O Er O Q L HOH O O M to OZ c 1 NGF FRAME 1 NGF FRAME 2 NGF FRAME 3 OSP EQT FOTSB EQT EQT FOTSB EQT OSP 30 00 12 00 L i 124 00 NGF Cross Connect Application with Equipment Jumper Storage www te com adc 1 952 938 8080 1 800 366 3891 Pre Terminated Block Adapter Only Block IFC Cable Equipment Jumper Cross connect Jumper KEY EQT Equipment Terminations FOTSB Fiber Optic Terminal Storage Bay FGS Fiberguide System NGF Next Generation Frame OSP Outside Plant Terminations NGF Optical Distribution Frame Things to Consider When Ordering How to Order Main Components of the NGF Catalog Number 1 Select the desired Frame based on application Quantity Fiber Main Distributing Frame Page 10 Front Facing Fiber Main Distributing Frame Page 11 Fiber Slim Rack Page 12 2 Select the desired Fiber Termination Blocks Preterminated Fiber Termination Blocks with Multifiber Cable IFC Pages 13 14 Preterminated Fiber Termination Blocks with MPO Connectors Page 15
6. IEC CABLE O oO O U O N KSL K EQTCABLE O H E H O xl Ts O g in CROSS CONNECT 2 14M O T i 1 O O Ii JUMPER n O ol Of Ul e Jou 0 AMO 0 Q RON O 110 i1 P l O ol i O Lo O dO c SPI ITI TT E EO HO B jou e Our 2 32 a T E ua NGF FRAME 1 i NGF FRAME 3 o E 3 13M Nn cy JE E i 10 3 E NGF Cross Connect Zoned by Vertical 2 1 1 Equation to OSP Ratio an o E n B N B a 15 8 8 8 5 8 i FGS O O 8 O O O l e O O O ie O f 1 O O ol O E O ADA IFC CABLE O O el O m EQTCABLE O O Q O CROSS CONNECT 2 14M O O JO O 7 os JUMPER 0 O O S O O O e O O O HIO A j O O e O O JO H O O LiT o O O il E V b ae 116 NGF Cross Connect Zoned by Frame 2 1 Equation to OSP Ratio www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Frame Accessories Fiber Optic Terminal Jumper Storage Panel Ordering Information Description Dimensions HxWxD Catalog Number Frame zoning by vertical 305 mm 12 FMDF 2 14 m x 305 mm x 610 mm NGF ACCFOTSB 7 x 12 x 24 Front facing F3MDF 2 14 m x 305 mm x 483 mm NGF F3ACCFOTSB 7 x 12 x 19 Frame zoning by frame 203 mm 8 FMDF left vertical 2 14 m x 203 mm x 610 mm NGF ACCFOTSB SL 7 x 8 x 24 FMDF right vertical 2 14 m x 203 mm x 610 mm NGF ACCFOTSB SR 7 x 8 x 24 Front facing F3MDF left vertical 2 14 m x
7. 1 7 mm patch cords Good Excellent Good Excellent 1 728 terminations using standard connectors 2 304 terminations using LC connectors Yes Yes Separate panel required On frame integrated jumper slack storage Sliding adapter pack Y 1 952 938 8080 1 800 366 3891 High Density Frame Solutions un c 9 O ua oO E m LL gt un c oO Q lt a rI NGF Optical Distribution Frame Things to Consider When Ordering Frame Capacity Requirements Important Facts on Trough Space www te com adc 144 FTB 96 FTB 72 FTB 1 728 frame 1 152 frame 864 frame NGF 12 frames 18 frames 24 frames Front Facing NGF 4 frames 6 frames 8 frames A Calculation assumptions Per Telecordia GR 449 CORE Issue 2 requirements 2 0 mm jumpers maximum recommended diameter for all NGF products 2 maximum jumper pile 50 of jumpers do not appear at any given place in lineup 50 rule Frame Lineup Capacity Comparisons 2 0 mm Jumpers Maximum Recommended Diameter for NGF Products NGF Frame Conventional Frame Conventional Frame 1 728 Fiber Terminations 1 152 Fiber Terminations 648 Fiber Terminations Horizontal trough space 30 10 5 Upper and Lower 5 Lower Maximum number of terminations allowed in 21 081 8 240 4 120 a frame lineup before exceeding 2 pileup M J NGF Frame Co
8. 203 mm x 483 mm NGF F3ACCFOTSB SL 7 x 8 x 19 Front facing F3MDF right vertical 2 14 m x 203 mm x 483 mm NGF F3ACCFOTSB SR 7 x 8 x 19 un c 9 O ua oO E m LL gt un c oO Q lt a rI www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Frame Accessories NGF to NG3 Frame Spacer Kit The 2 5 inch wide frame spacer kit is required for transition between next generation frames NGFs and NG3 frames The kit includes six rear trough adapters that ensure the rear cable management features of both fiber frames are utilized Tie brackets and a kick plate are also included for a secure installation For technical documents outlining the proper procedure for making these transitions please contact your ADC sales representative Ordering Information Description Catalog Number Mounts on left side of NGF frame NG3 NGFTRNTWN7AOR and right side of NG3 frame Mounts on right side of NGF frame NG3 NGFTRNTWN7AOL and left side of NG3 frame wn c 9 PEA 2 4 a 9 EDO o p E a E Tila gt Sy 2 un E S Lr B e i c wu o 7 Z Ir Md C p J Id IL e W E J LL on H 8 Frame Spacer Kit NG3 NGFTRNTWN7AOL Shown www te com ad
9. Adapter Only Fiber Termination Blocks Page 16 Adapter Only Fiber Termination Blocks Conversion Kits Page 17 Fiber Combination Blocks Pages 18 19 Splice Tray Page 20 Splice Protector Sleeve Page 20 3 Fiber Optic Terminal Jumper Storage Panel Pages 22 24 12 W universal Page 24 Front Facing 12 W universal Page 24 8 W left or right orientation Page 24 Front Facing 8 W left or right orientation Page 24 Optional Equipment 4 MicroVAM Chassis Page 21 Modular Splitter Block Page 21 6 NGF to NG3 Frame Spacer Kit Page 25 7 End Guard End Guard universal Page 26 5 Front Facing End Guard universal Page 26 8 Work Shelf Page 26 9 Frame Extender Page 27 10 Grounding Kit Page 27 gt AC Outlet Kit Page 27 12 Frame Installation Kit Page 28 gt UJ Isolation Pad Page 28 14 Cable Clamp Kit Page 29 A 15 Sliding Adapter Pack Page 30 16 Patch Cord Pages 103 107 17 In Line Attenuator Page 108 See page 31 for standard cross connect patch cord lengths www te com adc 1 952 938 8080 1 800 366 3891 High Density Frame Solutions NGF Optical Distribution Frame Fiber Main Distributing Frame The zone 4 rated fiber main distributing frame FMDF is the cornerstone of the NGF product line The footprint of the frame is GR 449 C
10. Facing NGF Application with Front and Rear Access MicroVAM Terminal Blocks www te com adc 1 952 938 8080 1 800 366 3891 un c 9 O ua oO E m LL gt un c oO Q lt a rI NGF Optical Distribution Frame Things to Consider When Ordering Zoning Recommendations fh fh i H H3 amo fh h i h h i i s E FGS i i G 2 00 F cur H ur ur TH o 0 B e po S IFC Cable I Q E i Cross connect 0 JUMPER Oir erum LU 84 00 e 0 Burn KEY S OSP OSP Pre term Block a SPLTR Front Access Splitter Block 17 FGS Fiberguide System EE FTB Fiber Term Bloce Tae FOTSB F O Terminal Storage Bay I EG End Guard E S PON Passive Optical Network E Ld JI E Pop 5 00 30 00 E 19 00
11. block if ordered with pigtails otherwise trays must be ordered separately The block is shipped with a cable clamp for OSP IFC The FCB occupies two mounting positions on a frame section Before ordering determine the block orientation FCBs may be ordered with a left l orientation mounts on the left side of the frame N a or a right orientation mounts on the right side N of the frame Fiber Termination Splice Block N c 9 O ua oO E m LL gt un c oO Q lt rI Ordering information follows on next page www te com adc 1 952 938 8080 1 800 366 3891 CS NGF Optical Distribution Frame Fiber Combination Blocks Definition of Variables Block Type General adapter type required in the FCB Block Capacity Maximum number of terminations that the FCB will accommodate when fully loaded Block Orientation Vertical column of the frame the FCB is to be mounted on Connector and Adapter Type Specific adapter connector type required in the FCB Pigtail Type Type of pigtail required Number of Pigtail Assemblies Number of pigtails to be pre installed in the FCB Splice Chip Type of splice chip required for splice trays Catalog Number NGF CB 2 Bloc
12. mounting options www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Front Facing Fiber Main Distributing Frame The zone 4 rated front facing fiber main distributing frame F3MDF is designed for single sided access applications and may be mounted up against a wall or back to back to save floor space Unlike the FMDF the more compact F3MDF is equipped with a single 9 inch horizontal trough on the front The F3MDF has 12 fiber termination block FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown below The frame provides sufficient vertical trough space for the highest termination density applications and includes built in jumper storage that will store up to 3 5 meters of jumper slack Left Right Jumper Vertical Vertical Storage Seed Panel A ES ETE E N FTB aa Mounting N Position POF c 12 le o 2 14m 7 Me A 5 3 wn as Front 0 s Horizontal E Trough 5 ye C E E f 7 1 ab Y f c Le 762 mm Go 483 an E 19 p Front ISO View Front View Side View Oo Ordering Information Maximum Description Dimensions HxWxD Termination Capacity Catalog Number NGF front facing 2 14 m x 762 mm x 483 mm 1 728 NGF F3MDF7A100 30 fiber main 7 x 30 x 19 2 304 using LC connectors distributing frame Each frame section includes heavy duty floor anchor bolts for co
13. terminated to the FTB Cable Length Required length of the cable terminated to the FTB Ordering information follows on next page www te com adc 1 952 938 8080 1 800 366 3891 High Density Frame Solutions un c 9 O ua oO E m LL gt un c oO Q lt a rI NGF Optical Distribution Frame Preterminated Fiber Termination Blocks with Multifiber Cable IFC Catalog Number NGF TB Block Type 1 SC 2 FC 4 LC Block Capacity B 72 C 96 M 144 Q 192 LC only Block Orientation L Left R Right Cable Exit Direction U Upward D Downward Connector and Adapter Type 1 Singlemode SC ultra polish SC angled polish FC ultra polish LC ultra polish 144 and 192 only LC angled polish 144 and 192 only ultimode 50 125 um Aqua SC LC 144 or 192 only Connector Type 2 Singlemode O No connector stub end 7 SC ultra polish L SC angled polish 2 FC ultra polish K LC ultra polish M LC angled polish Multimode 50 125 um Aqua O No connector stub end INE SC E LC Other configurations are available upon request Please contact ADC Technical Assistance Center www te com adc 1 952 938 8080 T T Cable Length Standard Single End
14. with Multifiber Cable IFC Preterminated fiber termination blocks FTBs are available with either indoor or outdoor rated cable in ribbon or stranded configurations All blocks are 10096 factory tested to guarantee continuity and reliable connections Preterminated FTBs make installation quick and easy reducing labor costs Before ordering determine the block orientation and cable exit direction Preterminated FTBs may be ordered with a left orientation mounts on the left side e of the frame or a right orientation mounts NA c on the right side of the frame The cable l ov 5 M Preterminated FTB with IFC exit direction will be either upward cables terminated to the rear side of the block exit up toward the top of the frame or downward cables terminated to the rear side of the block exit down toward the bottom of the frame Tf nim ni avn Definition of Variables Block Type General adapter type required in the FTB Block Capacity Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Connector and Adapter Type 1 Specific adapter connector type required at the FTB Connector Type 2 Specific connector type required at the far end opposite the FTB Cable Type Type of cable to be
15. 4 Front ISO View Front View Side View NGF ACCFOTSB Shown Ordering information follows on page 24 www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Frame Accessories Fiber Optic Terminal Jumper Storage Panel Zoning Recommendations N N N N E i E Y N J FGS j o HIS RANA o O Tor O HAI O O O go LA LU i o i Q O or O U Q O O Jol en of lo O 3 OE M
16. CISOPFS12X19 NGF ACCISOPEG24 NGF ACCISOPEG19 1 952 938 8080 1 800 366 3891 www te com adc NGF Optical Distribution Frame Panel Accessories Cable Clamp Kit Cable clamp kits are available for securing IFC OSP cable or equipment FOT jumpers on the rear of the FTB Each FTB has three cable clamp mounting positions Cable clamp kit for FOT patch cord includes Cable clamp bracket 1 each O ring 1 each Screws 2 each Cable clamp kit for IFC OSP cables includes Clamp cover 1 each Clamps 2 each 0 5 Grommet inner diameter 1 each 0 6 Grommet inner diameter 1 each 0 7 Grommet inner diameter 1 each 14 6 AWG split bolt 1 each n Shield bonding connector 1 each 1 foot lead wire 1 each 2 6 AWG ring terminal lug 1 each Clamp cover plate 1 each Nn cd E S E gt Description Catalog Number Cable clamp kit for FOT patch cords included with fiber termination NGF ACCCLMP04 o blocks loaded with adapters only a Cable clamp kit for IFC OSP cables dielectric cable without NGF ACCCLMP08 E grounding hardware included with fiber termination blocks with IFC E One NGF ACCCLMP08 is also included with each cable clamp kit and block conversion kit see page 17 www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Panel Accessories Sliding Adapter Pack Sliding adapter packs house groups of fibe
17. Frame Installation Kit Frame installation kits may be used on network frames and are seismic zone 4 rated Computer floor kit includes Threaded rods 4 each 5 8 11 x 30 Heavy nuts locks and flat washers 12 each Nuts with springs 4 each 1 2 x 30 and shoulder washers Unistrut and anchor kit 1 each 10 Overhead support kit includes Designation card holder 1 each Two bar channel 4 each Framing clip with 0 56 4 each Framing clip with 0 69 4 each Clip J bolt 4 each 1 2 13 x 18 long Threaded rod 2 each 5 8 x 18 long Hex nut 4 each 1 2 x 13 Hex nut 4 each 5 8 x 11 Ordering Information Description Catalog Number Frame installation kit for Computer floor FDF ACC 146 Overhead support RINST TOP7 un c 9 O ua oO E m LL gt un c oO Q lt a rI Isolation Pad A template for frame installation providing isolation between the frame and the ground Ordering Information Description Catalog Number Isolation pad for NGF FMDF and equipment frames NGF front facing F3MDF and equipment frames NGF slim racks 8 W NGF F3ACCFOTSB SL and NGF3ACCFOTSB SR 8 W NGF ACCFOTSB SL and NGF ACCFOTSB SR NGF ACCFOTSB storage panels NGF F3ACCFOTSB storage panels End guards for 610 mm 24 deep FMDF frames End guards for 483 mm 19 deep F3MDF frames NGF ACCISOP30X24 NGF ACCISOP30X19 NGF ACCISOP19X19 NGF ACCISOP8X19 NGF ACCISOP8X24 NGF ACCISOPFS12X24 NGF AC
18. NGF Optical Distribution Frame Introduction Frame ADC s next generation frame NGF product line has fiber frames designed to fit a variety of network applications Each frame option is designed with an emphasis on superior cable management and ease of use including features such as ample trough space for cable and jumpers easy access to connectors and storage for jumpers The frame sections are shipped from the factory fully equipped with all cable management hardware including integrated jumper slack storage Fiber Termination Block FTB ADC s FTB is available with industry standard adapters in block configurations of 72 96 and 144 positions Also a 192 position FTB is available using LC adapters FTBs utilize sliding adapter packs to gain easy access to both the front and rear terminations To accommodate varying network requirements and speed installation FTBs can be ordered with adapters only or preterminated with either intrafacility cable IFC or outside plant OSP cables Fiber Combination Block FCB Our FCB provides termination and on frame splicing capabilities This configuration occupies two mounting positions on the frame section They are available with industry standard adapters in block configurations of 72 96 and 144 positions An FCB with 192 positions is also available using LC adapters Value Added Module Block VAM Adding signal management and enhancement functions such as splitters couplers and wav
19. ORE Issue 2 compliant This innovative frame has six 5 inch horizontal troughs for a total of 30 inches of horizontal trough space This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability and removal The frame has 12 fiber termination block FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below The frame provides sufficient vertical trough space for the highest termination density applications and includes built in jumper storage that will store up to 3 5 meters of jumper slack The NGF is designed such that only a single jumper length 6 meters is required to go between any two termination points within a frame Left Right Rear Jumper Vertical Vertical Horizontal Storage Trough Panel ge p 6 en i 1 x F bagani N rm m Mounting b Position 12 E N 2 14 m L ak Nn c 9 O ua oO E m x LL gt wn c oO Q lt rI q 762 mm oe j 610 mm 24 gt Front ISO View Front View Side View Ordering Information Maximum Description Dimensions HxWxD Termination Capacity Catalog Number NGF fiber main 2 14 m x 762 mm x 610 mm 1 728 NGF MDF7A100 30 distributing frame 7 x 30 x 24 2 304 using LC connectors Each frame section includes heavy duty floor anchor bolts for concrete floor applications See page 28 for additional
20. c 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Frame Accessories End Guard End guards provide protection for the fibers entering and exiting frames at the end of a lineup They are designed for universal fit to be used on either end of the lineup Ordering Information Description Dimensions HxWxD Catalog Number FMDF end guard 2 14 m x 127 mm x 610 mm NGF ACCEGDOO7 7 x5 x 24 Front facing F3MDF end guard 2 14 m x 127 mm x 483 mm NGF F3ACCEGDO007 7 x5 x 19 Work Shelf The work shelf can mount at any one of six positions within the 30 inch NGF frame and anywhere along the height of the frame It provides a surface for miscellaneous objects i e isopropyl alcohol tissues and cotton swabs for cleaning connectors also provides a writing surface or serves as an aid in field terminating cables and jumpers Ordering Information Description Catalog Number Work shelf 762 mm 30 NGF ACCSHELF 1 30 un c 9 O ua oO E m LL gt un c oO Q lt a rI www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Frame Accessories Frame Extender Frame extenders are used to extend the height of a 7 foot frame to the appropriate ceiling height so that it can be secured overhead Ordering Information Description Catalog Number Frame extender 762 mm 30 Wide Frames Slim Rack
21. ed 016 16 m 50 023 23m 75 031 31 m 100 046 46 m 150 061 61 m 200 077 77 m 250 092 92 m 300 122 122 m 400 153 153 m 500 Non Standard Use XXX for non standard length in meters Cable Type IFC Riser Singlemode ZB 72 fiber stranded KA 72 fiber ribbon ZC 96 fiber stranded EG 96 fiber ribbon ZD 144 fiber stranded FJ 144 fiber ribbon GT 192 fiber stranded 2 x 96 EJ 192 fiber ribbon 2 x 96 Multimode 50 125 um LOMMF 300 m WE 96 fiber stranded WG 144 fiber stranded iE 192 fiber stranded 2 x 96 1192 and 144 blocks using block type 1 or 2 cannot be used in legacy 26 wide NGF frames Panels using ADC s standard cable offering have a shorter lead time than panels using a specific cable manufacturer ADC provides GR 409 compliant cable that meets or exceeds our high quality standards Standard cable offering above will use Corning SMF28 e Sumitomo Alcatel or similar singlemode fiber based on current market availability Due to space limitations do not use Tracerlight patch cords in the 192 block See Pages 97 98 to configure breakout kits for configurations using stubbed IFC ribbon cable 5 It is standard practice to use aqua colored adapters with laser optimized multimode fiber for identification of 10 Gigabit circuits See previ
22. elength division multiplexers optimizes the value of your fiber network by providing nonintrusive access to the optical signal for monitoring and testing signal integrity There is a block configuration available to accommodate Micro Value Added Modules MicroVAMs for applications requiring splitters or WDMs Fiber Optic Terminal Storage Panel ADC s fiber optic terminal storage panel is used as a storage apparatus for up to 16 feet of equipment FOT jumpers at the fiber frame lineup This panel can be installed between fiber frames and at the end of a lineup un c 9 O ua oO E m x LL gt un c oO Q lt rI www te com adc 1 952 938 8080 1 800 366 3891 www te com adc NGF Optical Distribution Frame Introduction Product Overview Recommended applications Description Number of fibers future growth potential Interconnect Cross connect Accommodates on frame splicing Accommodates off frame splicing Density terminations per frame Front access to rear connector VAM capabilities Slack storage location ee access Medium to large fiber count applications or any space constrained applications Highest fiber count solution available High density solution using 72 96 144 and 192 position blocks FTB Up to 29 177 in 17 frames using 144 position blocks SC connectors and 1 7 mm patch cords Up to 32 939 in 15 frames using 192 position blocks LC connectors and
23. entation mounts on the left side of the frame or a right orientation mounts on the right side of the frame The cable exit direction will be either upward cables terminated to the rear side of the block exit up toward the top of the frame or downward cables terminated to the rear side of the block exit down em S 299 mm 11 75 toward the bottom of the frame All blocks with adapters only are configured to terminate single or dual jumpers on the rear of the block If a multifiber breakout 483 mm 19 style cable i e OSP IFC is to be terminated to the rear of the block a separate clamping kit and replacement rear storage area kit is required see page 17 ADIDAS LETT ALL EE Y M as 165 mm 6 5 Bd When using the fiber optic terminal jumper storage panels an from page 24 a cable exit UP block must be used 144 Position Right Upward FTB Definition of Variables Block Type General adapter type required in the FTB Block Capacity Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter Type Specific adapter type required in the FTB un c 9 O ua oO E m LL gt un c oO Q lt a rI Catalog Number
24. gle fiber fusion Available in 24 position MT Mechanical mass fusion Splice Protector Sleeve The splice protector sleeve is constructed to protect a splice post fusion It is made from heat shrinkable material and contains a built in strength member for physical protection of the fusion splice The splice protection sleeve is placed on the fiber before making a splice moved over the splice when the splice fusion is complete and shrunk into place They are available in either single fiber or mass fusion sleeves 60 mm 2 mm 1 5 mm H 2 4 0 08 Heat Shrink Sleeve 56 mm 1 mm 2 2 0 04 Single Fusion Splice Protector Sleeve FST ACCOO1 Stainless Steel Strength Member Hot Melt un c 9 O ua oO E m LL gt un c oO Q lt a rI 3 8 mm 0 15 40 mm 0 16 4 Mass Fusion Splice Protector Sleeve FST ACC006 0 14 maximum Ordering Information Description Catalog Number Splice protector sleeve for Single fiber single fusion 60 mm 2 4 length 1 each FST ACCOO1 Single fiber single fusion 40 mm 1 6 length 1 each FST ACCO05 12 fiber ribbon mass fusion heat shrink 40 mm 1 6 length 1 each FST ACC006 Other configurations are available upon request Please contact ADC Technical Assistance Center ww
25. k Type 1 SC a FC Splice Chip O LC 3 Mechanical mass fusion 5 6 Nortel QPAK 24 fiber amp Block Capacity Connactorand heat shrink fusion i B 72 Adapter Type Number of E C 96 Singlemode Pigtail Assemblies E M 144 2 7 SC ultra polish 06 72 position panel 2 Q 192 LC only 122 L SC angled polish 08 96 position panel un 2 FC ultra polish 12 144 position panel K LC ultra polish 16 192 position panel c Block Orientation 144 and 192 only o Lett M LC angled polish Pigtail Type I BEI Right 144 and 192 only 1 12 fiber stranded Multimode 5 12 fiber ribbon 50 125 um Aqua IM SC eu LC 144 or 192 only 1192 and 144 blocks using block style 1 or 2 cannot be used in legacy 26 wide NGF frames Must use Nortel QPAK splice chip in 144 and 192 blocks when splicing 24 single fibers Due to space limitations do not use Tracerlight patch cords in the 192 block Only available in singlemode Other configurations are available upon request Please contact ADC Technical Assistance Center www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Fiber Combination Block Accessories Splice Tray For use when splice trays are not included with block at time of order Catalog Number FST DRS T Number of Splices Splice Tray Type 12 12 splices FT Bare fusion 24 24 splices HS Heat shrink sin
26. ncrete floor applications See page 28 for additional mounting options www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Fiber Slim Rack The fiber slim rack is designed for lower density applications than the FMDF or F3MDF It has six fiber termination block FTB mounting positions and is designed for single sided access applications The slim rack is intended for use in a single frame application and should not be used in a multi frame lineup The built in jumper storage panel will store up to 3 5 meters of jumper slack When ordering FTBs for the slim rack note that only LEFT oriented blocks are used on this frame FTB Mounting m Z Position Jumper Storage Panel 2 14m 7 D 483 mm 483 mm 19 Eds Side View Front View shown with covers open Ordering Information Front ISO View un c 9 O ua oO E m x LL gt wn c oO Q lt rI Maximum Description Dimensions HxWxD Termination Capacity Catalog Number NGF fiber slim rack 2 14 m x 483 mm x 483 mm 864 NGF SLM7A100 7 x 19 x 19 1 152 using LC connectors Each frame section includes heavy duty anchor bolts for concrete floor applications Not rated for zone 4 applications See page 28 for additional mounting options www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Preterminated Fiber Termination Blocks
27. nsiderations NGF Frame Front Facing NGF Frame Slim Rack N Flexibility ability to grow frame lineup Yes Yes No Interconnect Supports Supports Supports Cross connect Supports Supports Supports On frame splicing Supports Supports Supports Off frame splicing Supports Supports Supports Rear access required Yes No No All front access No Yes Yes panda 30 Wide x 30 Wide x 19 Wide x p 24 Deep 19 Deep 19 Deep Horizontal trough space available 30 9 N A E Block and Frame Termination Capacity e NGF Block Termination Capacity NGF Frame Termination Capacity Min Max Patch Cord Diameter 72 864 2 0 96 1 152 2 0 144 1 728 2 0 192 LC connectors only 2 304 1 7 J 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Things to Consider When Ordering Zoning Recommendations IFC IFC Equipment Us A NOTE Radius Limiters On FOTSB are Jumper from Removed at these Six Locations Equipment Optical H to Allow IFC to Pass into FTB s O H m QOOOOOOOOOOOOOOO amp Equipment Patch Cord From FOT Storage Bay H e Fibers are Fanned Out and Terminated to the Back Side of the Adapters on P the Sliding Adapter Packs O Cable Clamp And Block Conversion Kit Required n When Bringing Cable Into Adapter Only Block H E x See Fiber Terminal Block FTB Detail gt
28. ous page for definition of variables 1 800 366 3891 NGF Optical Distribution Frame Preterminated Fiber Termination Blocks with MPO Connectors Fiber termination blocks FTBs with MPO connectors provide MPO connectability on the rear of the block for easy connection of MPO fiber cables The termination portion of the fiber block utilizes sliding adapter packs to gain easy access to standard connectors and adapters on the front of the block and provides a location for standard patch cord connections The block is internally cabled at the factory for easy installation and occupies one position of the frame Before ordering determine the block orientation needed as the blocks may be ordered with a left orientation mounts on the left side of the frame or a right orientation mounts on the right side of the frame AAA NAAA AAA M L LLL va YA A R MM Preterminated FTB with MPO Connectors Definition of Variables Block Capacity Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Front Connector and Adapter Type Specific adapter connector type required at the FTB Pigtail Type Type of pigtail used within the FTB Number of Pigtail Assemblies Number of pigtails to be pre installed in the FTB Catalog Number NGFMP 0 Block Capacity C 96 M 144 Q 192 LC only
29. plitter Modules Catalog 102902AE at www adc com or contact ADC Customer Service High Density Frame Solutions www te com adc 1 952 938 8080 1 800 366 3891 Nn c 9 O ua oO E m x LL gt wn c oO Q lt rI NGF Optical Distribution Frame Frame Accessories Fiber Optic Terminal Jumper Storage Panel The fiber optic terminal jumper storage panel is an optional filler panel that provides up to 5 meters 16 4 feet of slack storage for jumpers that run between terminal equipment and the rear ports of an NGF terminal block in cross connect applications This slack storage capability allows for greater flexibility in determining jumper lengths and allows for use of more standard length jumpers This panel is installed within the NGF frame lineup between NGF frames The fiber optic terminal storage panels are available in two different configurations depending on the way the NGF frame system is zoned NGF frames can be zoned by vertical or by frame A 12 inch wide panel is available that serves two verticals one on each side for use when frames are zoned by vertical Also 8 inch wide versions are available that serve a single vertical left or right for use when frames are zoned by frame Cover ae E NT 2 4 Radius E Y ud ur k h ly 2 14 a E 1 JT S k a 9l 4 e 4 r y 4 f ia 6 6 A e gt gt 305 mm 12 610 mm 2
30. r 144 Block Conversion Kits on the block style originally purchased 144 Position Right FTB Shown with IFC Conversion Kit Loaded Ordering Information Description Catalog Number Block type originally purchased 72 position blocks NGF ACCOSPKITO2 96 position blocks with rear cable management Ordered before June 2002 NGF ACCOSPKITO1 96 144 or 192 position Left Up blocks NGF ACCRCMSLU 96 144 or 192 position Right Up blocks NGF ACCRCMSRU 96 144 or 192 position Left Down blocks NGF ACCRCMSLD 96 144 or 192 position Right Down blocks NGF ACCRCMSRD High Density Frame Solutions Cable Clamp 144 Position FTB Loaded 144 Position FTB Loaded with with Jumpers Multifiber Breakout Cable www te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame Fiber Combination Blocks Fiber combination blocks FCB provide the option to splice IFC OSP cables on the frame with factory installed fiber pigtails The blocks are available with several different adapter types in block configurations of 72 96 or 144 positions Also a 192 position FCB is available using LC adapters The termination portion of the fiber combination block utilizes sliding adapter packs to gain easy access to connectors on both the front and rear side of the block The block is available with factory installed pigtails for easy installation Splice trays are shipped with the
31. r optic adapters and are mounted in fiber termination blocks to provide easy access to connectors Sliding adapter packs are available with SC FC and LC adapters The adapters come in packs of two four six and eight depending on the adapter type and the desired termination density See table below for configuration guidelines Sliding Adapter Pack Configuration Guidelines bh Block Adapter Pack Adapter Pack Capacity Adapter Type Configuration Type 72 position SC 2 pack 4 pack A 72 position FC 6 pack E 96 position SC FC 4 pack 4 pack J 144 position block code M SC FC LC 6 pack 6 pack K GU 192 position block code Q LC 8 pack 8 pack J J n c 9 g Catalog Number v NGF SAP O0 00 E S LL Adapter Type Adapter Pack Type 2 Singlemode A 2 pack 4 pack c 7 SC ultra polish E 6 pack E L SC angled polish J 4 pack 4 pack 2 FC ultra polish K 6 pack 6 pack K LC ultra polish all block code M blocks 192 and 144 only M LC angled polish 192 and 144 only Multimode 50 125 um Aqua IM SC C LC 18 pack 8 pack with LC configuration Other configurations are available upon request Please contact ADC Technical Assistance Center www te com adc 1 952 938 8080 1 800 366 3891 CS NGF Optical Distribution Frame Frame Accessories Standard Cross Connect Patch Cord Leng
32. ths Total Number of AS E Sections Traversed ud Meters Feet Same frame 6 m 18 Adjacent frames 7m 23 3to4 8m 26 5 to 6 10 m 33 7to8 11 m 36 K 91010 12 m 39 p Depending on office requirements 11 or more frame sections may require the use of interbay tie panels For additional information please call ADC Technical Assistance Center 1 800 366 3891 For recommended cross connect method and installation instructions refer to User Manual ADCP 90 285 Ordering Information for Patch Cords and Attenuators ADC offers a comprehensive line of cable assembly and accessory products including patch cords IFC assemblies attenuators FasTerm connectors and adapters to meet the demanding needs of today s network Please refer to the Fiber Cable Assemblies Catalog 102880AE at www adc com for more detailed information For your convenience ordering information for patch cords and attenuators can also be found on pages 103 108 High Density Frame Solutions www te com adc 1 952 938 8080 1 800 366 3891
33. w te com adc 1 952 938 8080 1 800 366 3891 NGF Optical Distribution Frame R Value Added Module VAM MicroVAM Chassis The new NGF MicroVAM chassis is designed to mount on all standard NGF frames and is interchangeable with termination splice and storage modules Each chassis accommodates up to 12 MicroVAM modules The NGF MicroVAM chassis accommodates MicroVAM modules only For information on ADC legacy MiniVAM chassis and modules please contact ADC Technical Assistance Center so lt MicroVAM Chassis Left Orientation Shown Loaded Ordering Information Description Dimensions HxWxD Catalog Number NGF MicroVAM chassis unloaded left orientation 300 mm x 455 mm x 132 mm NGF VSPM 7000L accommodates 12 MicroVAM modules 11 8 x 17 9 x 5 2 NGF MicroVAM chassis unloaded right orientation 300 mm x 455 mm x 132 mm NGF VSPM 7000R accommodates 12 MicroVAM modules 11 8 x 17 9 x 5 2 Value Added Module VAM System ADC offers an expansive line of monitor splitter WDM and CWDM VAM plug in modules designed to meet all application needs Please reference the Value Added Module VAM System Catalog 101663AE for details at www adc com or contact ADC Customer Service NGF Modular Splitter Block and Outside Plant Splitter System For modular splitter block solutions for NGF frames and Outside Plant Splitter Solutions please reference OmniReach FTTX Solutions Passive Optical S
Download Pdf Manuals
Related Search
Related Contents
SMS Smart Media Solutions PL200006 SOFTWARE DE ATENCIÓN PRIMARIA EN SALUD GE 164 D2588P063 Microwave Oven User Manual Philips Azur Ionic Steam iron GC4440 Samsung Galaxy S Kasutusjuhend(GINGERBREAD Ver.) KTM 300SX Motorcycle User Manual BH-583B 取扱説明書 TT User Setup User Manual Parcours STR PVC 3 - Sotra Copyright © All rights reserved.