1. m 11 Electric diagram generator main winding b b winding Ignition coil Stepping motor Induction winding SMART switch Inverter unit Y A Output indicator 7 Overload indicator E alert controller E Ez Beer Oil alert indicator p Ignition unit E Ignition coil Y Spark plug Oil alert system Engine switch Side 34 CE Overensstemmelseserklaering DK CE Certificate of conformity GB CE verensst mmelse SE CE Konformit tserkl rung D CE Certificat de conformit F CE Conformiteitsverklaring NL Deklaracja zgodno ci CE PL CE Vaatimuksenmukaisuus todistus SF Hexnapauma cooreercrena EC RU EU importor e EU importer e EU import r e Der EU Inporteur e EU importateu e Europees importeur e Importer europejski e EU maahantuoja e Umnoptep e Texas Andreas Petersen A S Erkl rer herved at materiel e Hereby certifies that the following e Undertecknad f rklarar p f retagets v gnar att e bescheinigt hiermit das die nachfolgenden Certifie par la pr sente que les machines d crites ci dessous e Verklaart dat e Niniejszym certyfikatem o wiadcza ze eT ten todistamme ett alla olevat e co BCeit OTBETCTBEHHOCTbIO 3AABNACT UTO e Generator benzin e Generator gasoline e Generator bensin e Diesel generator e Essence Groupe lectrog ne e Benzine generator e Benzyna agregat e Bensiini Aggregaatti e BeHauHoBblA l eueparop e Type TGE3000TI Er fremstillet i overensstemmels
2. 2004 2 Betjeningsvejledning User manual Generator TGE 3000 Ti Texas Andreas Petersen A S Knullen 2 DK 5260 Odense S Tlf 6395 5555 Fax 6395 5558 posto texas dk www texas dk Page 1 m ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL ADVARSEL BEM ERK L s altid betjeningsvejledningen f r brug af din generator Brug aldrig generatoren i et lukket lokale omrade Udstadningsgas kan medfare kv lning V r opm rksom p ikke at komme i kontakt med motorens blok og udst dning da den bliver meget varm under k rsel Brug kun godkendte kabler Benzin er meget brandfarligt v r derfor forsigtig med p fyldning af br ndstof P fyld ikke benzin i n rheden af ben ild t ndte cigaretter gl der eller lignende T r altid spildt benzin grundigt op N dstr ms generatorer til bygninger m kun tilsluttes af en autoriseret elektriker som skal rette sig efter de g ldende love Ukorrekte tilslutninger kan for rsage at str m l ber retur til generatoren Dette kan medf re at personer der kommer i kontakt med generatoren kan f elektrisk st d Efter str mmen er genoprettet kan generatoren eksplodere br nde eller medf re brand i det elektriske system Check altid alle tilslutninger f r du starter maskinen Dette kan forebygge uheld Placer altid gene
3. which holds the lid remove the lid Wash the filter thoroughly in a non flammable fluid Let the filter dry thoroughly Soften the filter in pure engine oil and squeeze the filter for redundant oil Putthe filter back in its place in the holder and in the machine Putthe plate back in its place and fasten with screws Page 27 Paper element Cover 7 3 Fuel filter PROCEDURE Stop the generator Tum the fuel switch to OFF Open the cover on the generators left side Remove the cover to the filter Remove the hose to the airfilter Remove the bolts and nuts which hold the base of the airfilter Remove the drain plug by turning it counter clockwise Clean the drain plug and the filter in a non flammable fluid Gather the filter ring and drain plug again Tighten safe again Mount the base of the airfilter with the hose and mount it on the engine Mount the airfilter and the cover AIR HOSE Va FR S Jh SAR TES Airfilter Cover Page 28 7 4 Sparking Plug PROCEDURE Remove the cover at the top of the generator Remove the sparking plug cover Remove dirt around the sparking plug Use a Sparking plug wrench to unfasten the sparking plug Check the sparking plug replace if the isolation has cracked Clean the sparking plug with a steel brush if you want to reuse it Measure the electrode distance be careful
4. GE REE EEE NE cai ocala a arrene aiaa needs 29 TA Spark SOMO RR T 30 8 Transport 0 D ooo etr CURIAM RYAN RUE vU t RU ER CEN RR RA 30 EE 31 10 Trouble Shooting anda 32 TRENG 33 AE eus CIR ES Tm 34 CE Certificate of conformity eerste 35 Page 19 m 2 Identification of components TGE 3000 Ti Fuse AC Overload AC out Overload AC Oil alarm Switch Fuel 3 Automatic current control SMART The engine speed is automatically held ideal when the current is disconnected The same way the speed goes up when you connect the current This ensures the fuel consumption being held ata minimum The automatic regulation does not work effectively if an even electric current is needed When the generator is to produce a heavy even current you shall place the switch in the OFF position in order to reduce changes in the current When you work with DC Direct Current always place the switch in the OFF position Page 20 m 4 Before starting Oil BEM ERK Always inspect the generator on a horizontal surface with a turned off engine The in built alarm system will automatically stop the engine before the oil level drops below the approved level In order to avoid unpredicted disconnection you shall check the oil level regularly Using the generator with too little oil can cause severe damages to the wear parts of the engine 2 stroke oil and non synthetic oil can shorten the li
5. If the generator is setto use automatic power supply SMART then the effect will be less than if it was off Off the generator gives 12 A ON the generator gives 4 A In order to prevent the possibility of a spark close to the battery you must first connect the charging cable to the generator and thereafter to the battery When dismounting start by dismounting by the battery When charging batteries which are still mounted in cars itis important that the frame cable has been removed from the pole of the battery After charging the frame cable is mounted on the correct pole This procedure prevents the risk of a short circuit between generator and the chassis of the car NOTE Do nottry to start a car while the generator is connected to the battery of the car The generator may be damaged Always check that the generator has been correctly connected to the battery Always respect the indicated instructions for use of battery Page 25 m 6 4 Stop TGE 3000 Ti STOP In case of emergency the generator can be turned off of the ON OFF switch on the side of the generator Turn the apparatus off and remove the plug from the generator Turn the generator off on the ON OFF switch on the side of the generator Turn fuel switch to OFF 7 Maintenance The purpose of the maintenance is to keep the generator in its best possible shape Repairs should always be ca
6. ARE RE 17 ERIL A EE E E E E E 35 Page 3 um 2 Kontrol Panel TGE 3000 Ti vekselstr m sikring j vnstr m sikring j vnstr m outlet Vekselstr m ud indikator Vekselstr m overbelastning oliealarm indikator t ndings kontakt SMART choker br ndstofhane vekselstr m outlet 3 Automatisk str m kontrol SMART Motor hastigheden bliver automatisk holdt ideel n r str mmen bliver frakoblet Liges k res hastigheden op ved tilslutning af str mmen Dette sikrer at braendstofforbruget bliver holdt p et minimum BEM RK Den automatiske regulering fungerer ikke effektivt hvis der kr ves en j vn elektrisk str m BEM RK N r der er valgt at generatoren skal levere en kraftig j vn str m placer da kontakten i OFF position for at reducere ndringer i str mmen BEM RK N r der arbejdes med DC j vnstr m placer altid kontakten i OFF position br ndstofhane vekselstr Page 4 n 4 1 For start Olie BEM ERK Check altid generatoren p en vandret overflade med stoppet motor Detindbyggede alarmsystem vil automatisk stoppe motoren inden olie niveauet falder under det godkendte niveau For at undg uforudset afbrydelse skal du checke olieniveauet regelmaessigt Brug af generator med for lidt olie kan medf re alvorlige del ggelser p motorens sliddele 2 takts olie og motorolie der ikke opfylder de korrekte godkendelser kan forkort
7. VARSEL Afbryd alle tilslutninger til generatoren far start ADVARSEL Fer brug skal generatoren jordes Dette ggres ved at forbinde jordingsudtaget p generatoren med en stel forbindelse evt et jordspyd jordingsterminal Page 6 ben for braendstof hanen ON em e EE ox Y or e y El s M dec I Choker ned Bo Oy Taendingskontakt gy Tr k langsomt i motorens startsnor indtil der f les modstand Tr k derefter kraftigt i t lang tr k Lad aldrig startsnoren l be tilbage af sig selv f lg den altid tilbage med h nden Skub chokeren ind mens maskinen varmer op Page 7 mb 6 Brug af generatoren For at forebygge elektrisk chok skal generatoren jordes Dette g res ved at forbinde generatorens stel udgang med et stel forbindelse f eks et jordspyd ADVARSEL BEM ERK Overskrid ikke str mstyrke gr nsen angivet for et almindeligt stik Forbind ikke generatoren til et lukket system i f eks et hus Dette kan medf re skader p b de kredsl bet og generatoren Foretag ikke ndringer p generatoren Forbind ikke flere generatorer i en parallelforbindelse Forl ng ikke udst dningen p generatoren Ved brug af forl ngerledning skal du kun bruge et kraftigt og fleksibelt kabel Maksimum l ngde for forl ngerledninger 1 5mm 60 meter 2 5mm 100 meter Under brug m du ikke placere generatoren i naerheden af andre e
8. able to vary if the load is too high 6 1 Alternating current 0 Let the generator preheat minimum three minutes before use PROCEDURE 5 Start the generator and note that the green light in the panel goes green 6 Make sure that the apparatus has been turned off 7 Insert the plug into the generator 8 Turn the apparatus on current receiver Continued overload of the generator can damage the generator and shorten the life of the engine Always inspect that the receiver apparatus works and is in good shape before use Ifthe apparatus starts performing irregularly or if the engine suddenly stops during operation you shall stop the generator and disrupt the current by removing the plug from the generator Page 24 mb 6 2 Overload If the generator is overloaded the relay will cutthe circuit In the same time the power to the outlet plug will be disconnected In this case stop the generator and check the source of the overload 6 3 Direct current 6 3 3 Connect the charging cables on the DC take off on the generator to the correct poles as shown on the drawing 6 34 X Startthe generator The take off for alternating current can be used with the direct current take off 12 V take off on the generator must only be used for charging 12 V automobile batteries By use of direct current take off the automatic current control must be turned off
9. e med f lgende direktiver e Conforms with the following directives e In bereinstimmung mit den folgenden Direktiven e Conforme aux directives suivantes e Conform de volgende normen e Odpowiada nast puj cym dyrektywom e On yhdenmukainen seuraavien direktiivien kanssa e CoorBercrByer CNEAYIOLUMM AMpekTUBAM e 89 392 EEC 93 68 EEC e 89 339 EEC e 73 23 EEC 2000 14 EF Materiellet er udf rt i henhold til f lgende standarder e Conforms with the following standards e In bereinstimmung mit den folgenden Standards e Conforme aux directives suivantes e Conform de volgende normen e Odpowiada nastepujacym standardom e On yhdenmukainen seuraavien standardien kanssa e CooraBercTByer cneayioLIUM cTaHaaptam e EN292 EN50081 1 e EN50082 1 EN55014 EN55011 ISO9001 Texas Andreas Petersen A S Knullen 2s DK 5260 Odense S Administrerende Direktor e Managing Director e Directeur e Algemeen directeur e Toimitusjohtaja e FeHepanbHbl n4pekrop Side 35
10. e motorens levetid Brug premium 4 takt olie som opfylder de g ldende krav AP norm SG eller h jere Skru skruerne der holder deekpladen pa bagsiden af generatoren las og fjern pladen Check olieniveauet ved at fjerne oliepinden og t rre den med en t r ren klud Inds t oliepinden uden at skrue den i Se olieniveauet p pinden Pafyld olie hvis n dvendigt Oliekapacitet 0 55 L daeksel til oliep fyldning P fyld olie hertil deeksel for oliep fyldning der oliep fyldningshul oliepind 4 2 F r start Benzin Brug almindelig 95 oktan benzin Brug aldrig olieblandet benzin 2 takt Undga at f st v snavs eller vand i tanken Efter p fyldning skru tankd kslet sikkert fast P fyld aldrig mere br ndstof end til det anviste m rke figur herunder Vinduet ved br ndstoftanken indikerer m ngden af br ndstof Fyld hertil braendstofdaeksel A K TOM br ndstofniveau br ndstoffilter Page 5 n 4 3 For start Luftfilteret Check at luftfilteret er rent og i god stand FREMGANGSM DE 1 Aben den venstre lage p generatoren 2 Afhasp de fire hasper der fastholder luftfilteret 3 Fjern luftfilteret fra kassen og check elementet d ksel papir element ADVARSEL Brug aldrig generatoren uden luftfilter Dette resulterer i at skidt og snavs bliver suget ind i motorens karburator Hvilket reducere motoren leve tid betydeligt 5 Start Rekyl AD
11. end generatoren LS a er der str m p batteriet NEJ oplad batteri JA a NEJ er der gnist fra t ndr ret udskift t ndr ret stadig ingen gnist Tag kontakt til et autoriseret Texas Power Line Page 16 mi 11 Elektrisk diagram GENERATOR J vnstr ms binding Hoved binding vekselretter warf o i warf o i teendings Step motor induktions vikling Gas kontakt W FP udindikator 3 overbelastning indikator olie alarm x M om controller m indikator teendingsboks teendspole H t ndr r t ndingskontakt Page 17 NOTE Always read the user manual thoroughly before using the generator Never use the generator in a closed room area Exhaust may cause suffocation The exhaust pipe becomes very hot during operation Do not touch the exhaust pipe after use Only use approved cables Fuel is very flammable be careful when filling with gasoline Do not fill when you are close to open fire lighted cigarettes sparks or similar Always clean spilled gasoline Standby power generators for buildings must only be connected by an authorised electrician who must comply with the regulations in question Incorrect connection can make the power electricity run back to the generator This can cause a electric shock if a person gets in contact with the generator After the power has been restored the generator may explode burn o
12. er 20 timer 100 timer 500 timer 1000 timer Olie Check p fyld X Skift X X Check X Luftfilter REE X Teendror BP6ES Check X Breendstof slange Check Hver 2 ar Udskift hvis n dvendigt Br ndstof Res X tank filter Udskift X 4 Check b r udf res oftere hvis generatoren bruges i st vede omgivelser Page 10 m 7 1 Olie skift BEM ERK Udskift olie mens olien er varm dette giver et komplet og hurtigt olieskift FREMGANGSM DE Fjern oliepinden Skru bundproppen l s H ld den brugte olie hurtigt over i en beholder P fyld den anbefalede olie og tjek olieniveauet BEM RK Skil dig altid af med den brugte olie p den bedste m de Dermed sk ner du milj et mest muligt oliebundprop Oliepind _ os 7 2 Luftfilter ADVARSEL Brug aldrig benzin eller anden brandbar vaeske til at rense luftfilteret med FREMGANGSM DE Luftfilteret er placeret verst p motoren indkapslet i en sort metalboks L sn skruen der holder l get fast og fjern derefter l get Vask luftfilteret grundigt i en ikke br ndbar v ske Lad luftfilteret t rre grundigt Bl dg r filteret i ren motorolie og pres det overskydende ud med fingrene S t filteret pa plads i holderen og monter l get papir element papir element daksel Page 11 dk 7 3 Breendstoffilter FREMGANGSM DE Stop maskinen S tbr ndstofhanen pa OFF ben
13. erminal Ej symbol Page 22 Open fuel ON ov Go oa DO Fed 99 Choker puri e oz apa or os BC ee i Bo fe Engine switch Pull slowly in the starting cord of the engine until you feel resistance Thereafter you pull one heavy long draw Never let the starting cord run back by itself always follow it with your hand Push the choker while the choker is warming up om ESA Al 9 lt z Gr Gi gp ox a SR Choker Page 23 mb 6 Operation of generator In order to prevent electric shock the generator must be grounded This is done by connecting the frame take off of the generator with a frame connections e g an earth auger NOTICE Do not exceed the voltage limit stated for a regular plug Do not connect the generator to a closed system in e g a house This may cause damages on both the circuit and the generator Do not make any amendments to the generator Do not connect more generators in a parallel connection Do not extend the exhaustion on the generator By using an extension cord you shall use a heavy and flexible cable Maximum length of extension cords 1 5 mm 2 60 meters 2 5 mm 100 meters During operation you must not place the generator close to any other electrical cables The DC exit can be used together with the AC exit but draw attention to the current intensity being
14. fe of the engine Use full synthetic premium 4 stroke oil which meets the demands in question Loosen the screws that tighten the plate on the backside of the generator and remove the plate Check the oil level by removing the oil stick clean it with a dry clean cloth Insert the oil stick without screwing itin See the oil level on the stick Fill with oil if necessary Oil capacity 0 55 L Maximum Fill oil here Oil stick 4 1 Before starting gasoline Use unlead 95 octane gasoline Never use oil mixed gasoline 2 stroke Avoid getting dust dirt or water in the tank After filling fasten the tank cover securely Only fill fuel to the indicated marking see figure below Maximum Fuel level Fuel filter Page 21 n 4 2 Before starting air filter Check that the air filter is clean and in good shape PROCEDURE Loosen the screws that fasten the plate on the backside of the generator and remove the plate On the top of the air filter a tap is placed press this down and the air filter is loosened Check the filter and clean it replace if necessary Never use the generator without an air filter This will result in dirt being drawn into the carburettor of the engine 5 Starting Disconnect all connections to the generator before starting Before use the generator must be grounded Connect the ground take off on the generator with a frame connection e g an earth auger Ground t
15. isk str mkontrol SMART vil udgangseffekten v re mindre end hvis den er slukket Slukket afgiver generatoren 12 A T ndt afgiver generatoren ca 4 A ADVARSEL For at forhindre muligheden for at skabe en gnist n r batteriet forbind da f rst ladekablet medbatteriet derefter med generatoren Afmonter f rst kablet ved generatoren HUSK altid plus til plus og minus til minus Ved opladning af batterier der stadig er monteret i biler er det vigtigt at bilens stelkabel er fjernet fra batteriets pol Efter endt opladning monteres stel kablet p den retm ssige pol Denne procedure udelukker muligheden for en kortslutning mellem generator og bilens chassis Fors g ikke at starte en bil mens en generator er forbundet til bilens batteri Generatoren kan blive beskadiget Check altid at generatoren er rigtig forbundet til batteriet ADVARSEL F lg altid de foreskrevne regler for brug af batterier Page 9 mb 6 4 Stop TGE 3000 Ti Sluk apparatet og fjern stikket fra generatorens stik S t generatorens t ndingskontakt p OFF S t breendstofhanen p OFF 7 Vedligeholdelse BEM ERK Form let med vedligeholdelsen er at holde generatoren i bedst mulig stand Reparationer b r altid blive udf rt p et autoriseret Texas Power Line v rksted hver gang 1 m ned hver3 mdr hver6 mdr hvert r Del eller eller eller ell
16. ke optimalt FREMGANGSM DE Fjern de 4 skruer der fastholder gitteret ved udst dningen og fjern gitteret Fjern gnistfanget og pakningen Tjek gnistfanget og rens det med en st lb rste Tjek pakningen og udskift den hvis den er beskadiget Monter pakning gnistfanger og gitter igen Opbevaring FREMGANGSM DE Skiftolien p generatoren Dreen br ndstof fra tanken ved at dreje braendstofhanen p ON og l sne karburatorens dr n skrue vist herunder Draen br ndstoffet til en passende beholder Fjer t ndr ret og h ld ca en spiseskefuld ren motorolie ind i cylinderen Tr k i startkablet 3 4 gange derved bliver olien fordelt Inds t t ndr ret igen d Tr k langsomt i generatorens startkabel indtil der f les do modstand Nu er generatoren klar til opbevaring Page 14 m 9 Specifikationer TGE 3000 Ti Dimension og v gt LxBxh 450 x 240 x 380 T r v gt 62 kg Motor Model TG 600 Motor Benzin Slagvolumen boring x slagl ngde 68 x 54 mm Omdr min min maks 3500 K ling Luft Oliekapacitet 0 55L Br ndstoftank kapacitet 3 6 L Volumen 196 cc Generator Volt V 230 Frekvens Hz 50 AC ud Ampere A 12 2 Effekt KW 3 0 DC ud 8A Antal faser 1 Page 15 m 10 Fejlfinding Motor starter ikke er generatoren tendt NEJ te
17. lagen p generatorens venstre side Fjern d kslet til luftfilteret og selve luftfilteret Afmonter slange til luftfilteret Fjern de bolte og m trikker der fastholder luftfilterets base Fjern braendstoftankens bundprop ved at dreje mod uret Rens bundproppen og filteret i en ikke flambar v ske Saml filteret gummiringen og bundproppen igen Stram sikkert til Monter luftfilterets base med slangen og monter p plads Monter selve luftfilteret og d kslet Luft slange m trikker luftfilterd ksel Filter Gummiring Bundprop Page 12 vinh 7 4 T ndr r FREMGANGSM DE ben l gen p generatorens venstre side L sn de to skruer der fastholder t ndr rsd kslet Fjern t ndr rsh tten Berstskidt og snavs v k fra t ndr ret Brug en t ndr rsn gle til at l sne t ndr ret Check om isoleringen er intakt Rens t ndr ret med en st lb rste M lelektrodeafstanden pas p ikke at beskadige elektroden Afstanden b r v re 0 7 0 8 mm Hvis t ndr ret er godt monter igen Monter t ndr rsh tten Monter d kslet med skruerne t ndr rsn gle t ndr rsn gle daeksel t ndr rsh tte Page 13 m 7 5 Gnistfanger ADVARSEL Hvis generatoren har v ret i brug er gnistfanget meget varmt vent til det er nedk let Gnistfanget skal udskiftes for hver 100 timer for at vir
18. lektriske kabler DC udgangen kan bruges sammen med AC udgangen men vaer opmaerksom p at stramstyrken kan variere hvis belastningen er h j 6 1 Vekselstr m ER Lad altid generatoren varme op i mindst tre minutter f r brug FREMGANGSM DE 1 Tjek at apparatet er slukket 2 3 4 str mmodtageren Inds t stikket i generatoren Start generatoren Inds t stikket i generatoren Vedvarende overbelastning af generatoren kan skade generatoren samt forkorte motorens levetid Unders g altid at modtagerapparatet virker og er i god stand f r brug Hvis et apparat under brug begynder at opf re sig unormalt eller pludselig stopper skal du stoppe generatoren og afbryde str mmen ved at fjerne stikket i generatoren Page 8 mb 6 2 Overbelastning BEM ERK Hvis generatoren bliver overbelastet vil generatorens rel sl fra Samtidig vil str mmen til apparatet blive afbrudt I tilf lde af dette stop generatoren og unders g kilden til overbelastningen 6 3 J vnstr m 6 31 Forbind ladekablerne p DC udtaget p generatoren forbind med de retm ssige poler p batteriet Plus til Plus og Minus til Minus 6 3 2 Start generatoren Vekselstr msudtaget kan ikke anvendes sammen med j vnstr msudtaget BEM RK 12 V udtaget p generatoren m kun bruges til opladning af 12 V automobil batterier Hvis generatoren er sat til at bruge automat
19. not to damage the sparking plug The distance should be 0 6 mm 0 7 mm Insert the sparking plug carefully and fasten it with a sparking plug wrench Normally you have to fasten a new sparking plug by turn by the means of the sparking plug wrench You only have to fasten a used sparking plug by 1 8 Y turn Mount the sparking plug cover Putthe cover back on the generator Sparking plug key Spark plug cover Page 29 m 7 4 Spark screen If the generator has been in use the spark screen will be very warm wait until it has cooled down The spark screen should be replaced every 100th hour in order to be in its best shape Remove the 4 screws that fasten the grating by the exhaust and remove the grating Remove the 3 screws that fasten the exhaust and remove the exhaust Remove the spark screen and the gasket Check the spark screen and clean it with a steel brush Check the gasket and replace it if damaged Remountthe gasket spark screen exhaust and grating 8 Transport and storage PROCEDURE Drain all gasoline from the tank into a container Tum the ignition switch of the generator to the ON position Remove the sparking plug cover and pull the starting cable 3 4 times Tum the ignition switch of the generator to the OFF position Fasten all screws securely Change the oil on the generator Remove the sparking plug and pour app
20. one spoonful of pure engine oil into the cylinder Pull the starting cable 3 4 times so that the oil is allocated Put the sparking plug back in its place Page 30 m Pull the starting cable of the generator slowly until you feel resistance Now the generator is ready to be stored 9 Specifications TGE 3000 Ti Dimensions and weight LxBxh 450 x 240 x 380 Dry weight 62 kg Engine Model TG 600 Engine Gasoline Stroke volume drilling x stroke length 68 x 54 mm Max speed min max 3500 Cooling Air Stroke volume drilling x stroke length 0 55 L Fuel tank capacity 3 6L Volumen 196 cc Generator Volt V 230 Frequence Hz 50 AC out Dp A 12 2 Effect KW 3 0 DC out 8A Number of phases 1 Page 31 n 10 Trouble shooting Engine cannot start is there fuel in the tank fill with fuel is the generator on NO turn on the generator gt is there enough oil NO fill with oil gt i sparkles the spark plug replace sparking plug NO still no sparkle NO Contact your dealer Page 32 The apparatus does not work Does the output lamp Does the alarm lamp light Check the machine works Contact your dealer Replace the electric apparatus or equipment No current in the DC take off Is the automatic safety system Connect the connected system Contact your delaer
21. r cause a burn in the electric system Always inspect all connections before you start the machine This can prevent an accident Always place the generator 1 meter away from buildings or other equipment during operation Only use the generator on a horizontal surface Draw attention to how the generator is to be stopped and understand all its functions Never leave the use of the generator to persons who have not received any instruction about the operation Keep children away from the generator during operation Using the generator with wet hands may lead to electric shock Never use the generator in rain or snow Always make sure that the generator does not become wet If you are going to use the generator in thin statums of air higher than 1500 meter above water surface you shall contact your Texas P ower line dealer for guidance Page 18 inh 1 Contents TAS Io QU PP RR Cc ER 19 2 Identification of components cus ndicut eter S Do b a 20 3 Automatic current control SMART MT 20 4 Before starting Oils EE EASES 21 4 1 Before starting gasoline RERO ETE 21 4 2 Before starting air filter eege eat 22 NNN 22 6 Operation of generator EE EE RE EE snelen tlbrdskeer 24 6 1 Alternating current 1M seesevevereesereese eve eveseren eee serene eee eee se seeren ener nere aN aT see 24 SERI EEREr 25 6 3 Direct DE eet 25 FEINER Emme 26 EEN ads 27 e UE 27 FANN 28 EE
22. ratoren 1 meter fra bygninger eller andet udstyr under brug Brug kun generatoren p et vandret underlag V r opm rksom p hvordan generatoren stoppes og forst alle funktioner Overlad aldrig brugen af generatoren til personer der ikke har modtaget instruktioner om brugen Hold b rn v k fra generatoren under brug Brug af generatoren med v de h nder kan medf re elektrisk st d Brug ikke generatoren i regn eller sne S rg altid for at generatoren ikke bliver v d Batterier indeholder syre beskyt derfor dine h nder og jne I tilf lde af kontakt skyl jeblikkelig med rindende vand og s g l ge Batterier udvikler brint hvilket kan v re yderst eksplosivt Undg kontakt med gl der flammer eller gnister Oplad batteriet i et vel ventileret omr de Hvis du skal bruge generatoren i tynde luftlag h jere end 1500 meter over vand overflade skal du kontakte din autoriserede Texas Power Line forhandler for vejledning Page 2 ih 1 Indholdsfortegnelse IEEE 3 FR Su uis EE EE EE E 4 3 Automatisk str m kontrol SMART E 4 AI EE 5 2 Fre 5 NN Ua ub P BRE uu cud 6 D Start SKY MEVS NER RE NH 6 Brad af HEBDO ID Boo asusta tees EE md afostidss M NE 8 ENN 8 62 0verbela mifit EEE EN ENN EN NE a SUME 9 A II A E 9 6 4 Stop TGE NNN eee 10 A A NER 10 Te 11 TREE NUTUS REN RN Rt 11 1 35 Ee DU NER A ou es A Ea Er ia AeA 12 A ana aas panes aa 13 EE E mM 14 ENN 14 DN 15 10 RO RR cm 16 IB M Sanz Ge r ES
23. rried out by an authorized Texas Power Line dealer Every After 1st Every 3 Every 6th Every year time month month month Part or or or eller 20 hours 100 hours 500 hours 1000 timer Oil Check Fill X Replace X X hir filter SE Sparking plug BPGES Check X Clean X Fuel filter Change 2 X1 Check should be carried out more often if the generator is being used in dusty areas X2 These improvements should be carried out at your local dealer Page 26 n 7 1 Changing oil AA A NANNING SO The ignition switch and upper part of the gasoline cover of the generator shall always be in the OFF position when changing oil NOTE Replace oil while the oil is still warm this gives a complete and quick oil change PROCEDURE Unloosen the screws that fasten the plate on the back side of the generator and remove the plate Remove the oil stick Pourthe used oil into a can Fill with the recommended oil and check the oil level Putthe plate back in its place and fasten the screws securely Always get rid of the used oil in the best way so that you save the environment as much as possible Oil drain plug Oil stick 7 2 Air filter Never use gasoline or other flammable fluids to clean the air filter PROCEDURE The air filter is placed on top of the engine covered in a black metal box Loosen the screw