1. If these operations above are normal the instrument is ready to operate If not the instrument may be damaged during transportation please contact technical support of manufacturer supplier 7 Control and Display 7 1 Control AM40 D Pro Push through agitator shaft Speed torque LED 2 18h LCD Display oe Power switch MODE switch overload LED Speed control knob Power switch Drill chuck Picture 4 7 2 Control AM20 D Default settings Speed control Set stirring speed press the button to start stop stirring Foro passante button function per asta Shift speed and torque display LCD displays the current Mode switch knob or speed value at initial running LCD displays the current ode Speed torque LED torque value when press the mode knob LCD display LCD displays the real working state and all setting values Yellow Green LED display light Different color of LED Power switch LED lights show the value for speed or torque that LCD screen LCD Display Speed control Speed torque light l knob currently displays Yellow LED light shows that LCD RPM Torque Power screen currently displays speed Green LED light shows switch that LCD screen currently displays torque Drill chuck Green Red LED display light Power switch LED light shows green when switch on LED light shows Overload red when starts overload protection When the torque protection light reaches limited value overload p
2. 100 50 100 240 50 60 130 70 50 2200 0 2200 LCD 60 LED light flash auto stop LED light flash auto stop 50000 0 5 13 14 x 220 83 x 220 x 186 2 8 2 6 IP21 5 40 80 Yes No 14 Disposal Information regarding the disposal of electrical and electronic equipment European Union Electrical and electronic equipment marked with the symbol on the side cannot be disposed of in landfills In accordance with EU Directive 2002 96 EC the European users of electrical and electronic equipment have the opportunity to give back to the distributor or manufacturer upon purchase of a new one The illegal disposal of electrical and electronic equipment is punished with an administrative fine
3. ARGO LAB AM40 D Pro and AM20 D Overhead stirrer User manual ARGO Contents l M E r ny cat ecdauatietag ae uut una datuedat te nedetaaaians cee nuctanancalce ates 2 SAS e ONS acts iecic E iacntaeta suctnmacamoumeneancitatacwoaneua sa saneacmomeeacee 3 PROPEL USE ciclo ics crocniesain inc dera A a neta iaaees 4 e the le eer renee Meee E eer ane nn on Cn Erne Ne ersten ner anne vere een ee 4 1 Rece vina INS CC COM enson esata tendon tatinalecatiiowss 4 2 ERN OLOM emeneey ee ceenen eaten R ty rene arto e ware 5 SY SLEMIASS e mD oe A iiaum 6 Ta E a a E N J Control and DiSplayesssr an cad scestalusel et vdiaat ann tadonnnesecuateds 7 1 Control AWIAO AD BBO aa E iedeestanaloateniatacanavateast 72 Control AM2 0 Drea O Ta S VAY E E EE E E OE AE E A E 8 SWITCH OM INSCEUMNCN ss2saisieets ines oj atvete elt iaateaeaieset ale set a stvet elt maateauaiecat Nasess 8 1 Eea Seu acetates ate e Gc esa icercaitoe sacra hehe esas e 9 Overload Protec Hoiessri s alltel eta esate tees 10 AEN I e E E E AAE N E A cee E E E ES VEE E E ce 11 Maintenance and Cleans vasca i NE aiii 12 Associated standards and regulations cccccccccececeeceeeeeaeeeeeessseeeeeeeeeess 13 Car atteristiche 1eCniCne x teinssnietaia a a E N 14 B FES oe cic le renee ea Mere en ie eine A er Ree ner Se E errr enn any ee 1 Warranty Thank you for purchasing an instrument Argo Lab This instrument is warranted under normal use for a period of 24 months from the date
4. Maintenance and Cleaning Proper maintenance can keep instrument working properly and lengthen its lifetime Do not spray cleanser into the instrument when cleaning Do not remove the power line when cleaning Only use recommended cleansers Dyes Isopropyl alcohol Construction materials Water containing tenside Isopropyl alcohol Cosmetics Water containing tenside Isopropyl alcohol Foodstuffs Water containing tenside Fuels Water containing tenside Before using other method for cleaning or decontamination the user must ascertain with the manufacturer that this method will not damage the instrument Wear the proper protective gloves during cleaning of the instrument 12 Associated standards and regulations Construction in accordance with the following safety standards EN 61010 1 UL 3101 1 CAN CSA C22 2 1010 1 EN 61010 2 10 Construction in accordance with the following EMC standards EN 61326 1 13 Caratteristiche tecniche Max stirring quantity H20 L Motor rating input W Motor rating output W Voltage VAC Frequency Hz Power W Speed range rpm Speed display accuracy rpm Speed display Max torque Ncm Overload protection Motor protect Max viscosity mPas Chuck range diameter mm Stand dia x 1 mm Dimension W x H x D mm Weight kg Protection class acc to DIN EN 60529 Temperature C Permission relative humidity RS232 interface 40 AM40 D Pro 20 AM20 D 120 60
5. electronically limited to achieve security stall and overload protection When the torque reaches limited value overload protection function will be started At the same time overload protection light flashes e Starts overload protection When the setting speed value does not match the current medium viscosity starts overload protection When the motor output shaft is stuck motor protection starts e Refer to Chapter 9 for the solutions of overload protection and motor protection 10 Faults e Instrument can not be powered ON when start stirring function Check whether the power cable is connected e Speed can not reach set point The setting speed value does not match the current medium viscosity please reduce speed then re start e Stirring function suddenly stop Overload protection light changed to red display area shows Er 03 indicate the A current failure is overload protection When the setting speed value does not match medium viscosity that caused overload protection should be first pressing speed control button to stop stirring function Restart stirring after lowered setting speed value If overhead protection continues starting then repeat the process and gradually reduce the speed Overload protection light changed to red display area shows Er 04 indicate the current failure is motor protection When the motor output shaft is stuck that caused motor protection should be first 11
6. main unit and the distance from main unit to the support holder by rotating the locking device Anti drop protector can be adjusted up or down ensure the locking position is suitable for fixing the main unit l Picture 1 and then attach the main unit to the stand b Install stirring impeller Plug the stirring impeller into the drill chuck and adjust the depth of stirring impeller into vessel Rotate Picture 2 the drill chuck with your fingers to fix the stirring impeller and then clockwise tighten evenly the drill chuck using chuck key Picture 3 Note 1 Overhead stirrer is a high speed running device The system are required to lock securely the corresponding components in each step of the assembly to avoid any movement of the main unit or stirring impeller which would be caused harm or damage to peripheral instrument and personnel 2 The stand is a support device for overhead stirrer The corresponding components are required to be locked securely to avoid any movement which would be caused harm or damage 6 Trial run Follow the instructions below to trial operate e Ensure the required operating voltage and power supply voltage matched e Ensure the socket must be earthed reliably e Connect the power cable ensure the power on and begin self checking e Rotate the stirring button and set stirring speed e Press stirring button and start stirring e Press again the stirring button and stop stirring
7. of purchase The warranty is valid only if the product is in original conditions It does not apply to any product or parts of it that have been damaged due to incorrect installation improper connections improper use accident or abnormal conditions of operation The manufacturer declines all responsibility for damage caused by failure to follow instructions lack of maintenance and any unauthorized modification 2 Safety instructions e Read the instructions carefully before use A N e Ensure that only qualified personnel using this tool e Do not heat flammable or highly volatile substances e Before use make sure the instrument is connected to an outlet with a CL ground connection e During the work you must prevent the risk of Spillage of liquids Breakage of glass containers e Follow the safety instructions guidelines and safety regulations e Do not touch moving parts e Place the instrument in a suitable area on a stable clean non slip dry and fireproof Do not use the tool in explosive atmospheres containing hazardous substances or under water e Increase gradually the speed e Observe the container when you set the speed to avoid splashing of the sample If the instrument is not working properly please decrease the speed of the motor e Attach the accessories on the move to avoid damage e Only use the original standard accessories listed in the accessories and follow the installation instructions to en
8. rotection function will be Power Overload started At the same time overload protection light flashes while the system stops running 7 3 Display Drill chuck Can be held stirring impellers et Set Push through If needed shaft can push through agitator agitator shaft Faults Set value display Power switch KO Switch ON or OFF the instrument Remote control PC Speed control Set stirring speed press the button to start stop stirring button function Picwreb Characters Description Picture 5 Table 2 S Display when set target speed value PC Display when using external probe Err Display in case of error happening Value When display this area shows setting value When set display area disappears this area shows running value Table 3 Switch on instrument 8 1 Initial sequence Place the overhead stirrer in safe and stable surface and connect power cable e Switch ON instrument e The instrument begins self checking 99 e When initialization is over displays set at the same time the area of value setting display flashes that indicate can be set speed value e Rotate speed control button to set stirring speed e LCD display no longer flashes when press speed button set disappear the stirring function start e Press speed button again LCD display flashes set display the stirring function close 9 Overload Protection Overhead Stirrer works continuous the motor current is
9. sure safety e Check the good condition of the instrument and accessories before use Never use damaged components The safety and operating performance are guaranteed only if the instrument and accessories described are in order Accessories must also be firmly connected to the device e Do not cover the instrument during operation e The voltage on the rating plate must correspond to the mains voltage e Keep away from strong magnetic fields e The instrument can be switched off or disconnecting it from disconnecting the cable from the instrument itself e The instrument may only be opened by trained service technicians e Keep out of the instrument by electromagnetic fields 3 Proper use The instrument has been designed to mix liquids of different densities in school labs chemical pharmaceutical industrial etc This instrument is not suitable for using in residential areas 4 Inspection 4 1 Receiving Inspection Unpack the instrument carefully and check for any damages which may have arisen during transport If it happens please contact supplier for technical support Note If there is any apparent damage to the system please do not connect to the power line 4 2 Listing of Items Item Qty Main unit Power cable User manual Key of drill chuck p p f p pk Table 1 5 System assembly a Install stand The stand must be assembled according to the following instructions Adjust the height of the
Download Pdf Manuals
Related Search
Related Contents
Manuale d`uso SP-820UZ Operations Manual Manuel d`opérations ESC/Java2 Implementation Notes Regina Plus 40T Regina Plus 90T A190146 Nikon D2H User's Manual Le Serious Games « Clim`Way www.philips.com/welcome EN User manual 1 Customer care and VISION SENSOR - f.energy Videoregistratore Digitale Manuale Utente DVRL4009 Copyright © All rights reserved.