Home

FA270RF Fixed English Installation Manual

image

Contents

1. If you reject the serial number the display flashes d with the device number followed by four times Flashes u4 Once the 4 digit user code is entered the display flashes u4 the first two digits and then the last two digits of the user code Flashes Ln Once the loop number is entered alternately flashes L with the loop number and the present function Wireless Key Function Chart Default Loop Functions Cont d Function Emtry S SA Loop 2 emg way Arm STAY a Arming Stay Loop i Close on board relay Arming Maximum Away Instant for2 seconds Arming Instant Panic Alarm Produces type of alarm amp 99 programmed in control panel 7 FA1 42C Loop 2 Manually Start a Relay Action 7 n FA130CP FA148C cane FA148CP FA162C FA168CP p 8 FA142C Loops AA OO frm smy Manually Stop a Relay Action 8 n FA130CP FA148C Arm AWAY I 34 Loop 1 FA148CP FA162C FA168CPS IB ee onen for 2 seconds Activate Relay as Programmed in 71 FA1220CV FA1340C Control A a i a danmernn 72 FA1220CV FA1340C 5804BD 5804BDV Activate Access Control Relay for NOTE If the loop is defaulted with a function e g Partition 0 FA1220CV FA1340C Arm Disarm and also is assigned to activate n Device Number programmed in panel to be controlled the on board relay the system performs BOTH functions Press the key Repeat step 6 for the rest of the loops of the wire
2. e Auto Enroll mode for programming wireless keys e Provides a method for deleting a serial number and re enrolling a new one in its place e Provides default settings for the wireless key functions Additional Features e Operates the on board relay in conjunction with the receiver e g to trip a garage door opener UL This feature is not intended for UL installations e Activates relays programmed into the control panel e Provides an End User mode to enable disable local wireless keys e g if a user accidentally loses a wireless key Refer to the FA270RF User Guide for this procedure INSTALLING THE FA270RF Locate the FA270RF in an area and at a height where it is 5 Connect the wires for the relay output if used to the convenient for user operation The FA270RF must be at terminals on the FA270RF s PC board least 10 feet from the control panel to ensure proper 6 Reattach the keypad to its case back operation of the RF receiver Refer to Figures 1 and the 7 Remove the clear protective films from the LCD display Wiring Table and perform the following steps to install the and install the keypad labels as required FA270RF Note Upon power up or exit of the Program Mode the FA270RF alternately flashes Ad and the 2 digit keypad address and the 2 digit receiver address on the display Press any key to display the system status 1 To remove the case back insert a small screwdriver blade at a downward angle into Slot
3. 1 through 3 Step Programming for an Installation WITH Local Wireless Keys 4 e The FA270RF is supplied with default settings for the functions of the wireless keys See page 3 e lf during the programming of the wireless keys you make a wrong entry and want to reprogram a wireless key simply press the key then enter the correct information Perform steps 1 6 in the Programming for an Installation Without Local Wireless Keys section Then perform the following steps Step Enter 3 House ID Enter the 2 digit House ID for the FA270RF 01 31 Note The House ID is needed only if RF keypads and or bi directional units are used and House ID source is set for Local The House ID entered here MUST match the House ID programmed in the RF keypad and the bi directional unit Press the key to continue Enter 8 Wireless Key Auto Enroll The FA270RF automatically advances to first available device number Note If all 8 devices have been enrolled the FA270RF beeps three times and continues to alternately flash oo and Press any button on the wireless key to enroll the serial number The keypad will beep three times Note If enrolling a wireless key 5804E in high security mode press all four buttons on the wireless key simultaneously Press the x key to accept the serial number OR press the key to reject the serial number If you accept the serial number the FA270RF beeps two times If y
4. 1 and twist the right side pops up Insert the screwdriver blade at a downward angle into Slot 2 and twist the left side pops up Insert the screwdriver blade at into right side narrow Slot 3 and twist 2 Route the wiring from the control panel through the opening in the case back See the control panel s instructions for proper wire run lengths 3 Mount the case back directly to a wall or electrical gang box 4 Connect the power and data wires from the control panel to the terminals on the FA270RF as indicated in the wiring table FA270RF 001 VO Figure 1 Removing the FA270RF Case Back WIRING TABLE aypan Control Panel AG Dataln Green Aux Pwr GND AG _ AuxPwr Red i O Note NO normally Open and C common are the connections for the relay output VY GANOC 0 S mee FA270RF 005 V0 Figure 2 FA270RF Wiring Connections APPLICATION GUIDELINES Use the following guidelines when planning an installation e Local wireless keys wireless keys programmed directly into the FA270RF may be used regardless of whether the RF receiver in the FA270RF is enabled or disabled e If using bi directional devices be sure to enable the transmitter module in the FA270RF e If transmitters are programmed into the control panel be sure to enable the receiver Make sure you do not exceed the number of receivers supported by the control panel e If a local wireless key is programmed to arm disarm o
5. CE OR FAULT Seller does not represent that the product s it sells may not be compromised or circumvented that the product s will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product s will in all cases provide adequate warning or protection Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT S FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT S WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty replaces any previous warranties and is the only warranty made by Seller on this product s No increase or alteration written or verbal of the obligations of this Limited Warranty is authorized First i alert NS X PROFESSIONAL SECURITY SYSTEMS 149 Eileen Way Syosset NY 11791 www firstalertprofessional com K1 4035V1 7 06 Rev A Copy
6. DC Frequency 345 MHz Sounder Piezo electric fire alarm is loud pulsing tone burglary audible panic alarm is two tone sound FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FEDERAL COMMUNICATIONS COMMISSION FCC Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manu facturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment of
7. K14035V1 7 06 Rev A First FA270RF flert _ Keypad Transceiver NS NS PROFESSIONAL SECURITY SYSTEMS INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The FA270RF Keypad Transceiver is a combination unit incorporating a normally open relay output and the functions of e FA270KP Fixed Addressable Keypad e 5881M RF Receiver e 5800TM Transmitter Module The FA270RF Keypad Transceiver may be used on any control panel that supports the FA270KP Keypad Wireless Features The FA270RF supports the following e 5828 5828V wireless keypads e RF jam detection when the receiver is enabled e Up to eight wireless keys locally programmed directly into e Low battery indications for the local wireless keys FA270RF without occupying any zones supported by the control e A nominal range of 200 for the RF transmitters some panel transmitters have a shorter range e Button type transmitters e g 5804 5804BD for local operation e Wireless keys for control panels that do not support RF e A maximum of 16 transmitters programmed into any 5800 themselves such as FA110C Series supported control panel e Sends status signals Armed Ready etc to bi directional e Wireless keys with high security e g 5804E units such as 5804BDV and 5828 5828V U The 5802 5802MN 5802MN2 5804 5804BD 5804BDV 5804E 5814 5816TEMP 5819 5819BRS 5819WHS 5828 5828V and 5850 L transmitters are not intended for UL installations Programming Features
8. anel s capacity or on a system that does not support 5800 Series wireless Refer to the FA270RF Application Guidelines section for installations that require these settings Note See the control panel s installation instructions for the acceptable keypad and receiver addresses f If you are using a wireless key in High Security mode 5804E in the control panel it will occupy one of the devices in the FA270RF Programming for an Installation WITHOUT Local Wireless Keys To program the FA270RF for an installation without any local wireless keys perform the see steps a Enter the Program mode by pressing the 1 and 8 keys Alternately flashes oo and two dashes simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds after removing the case back Enter 1 Keypad Address Enter the 2 digit keypad address 01 31 Alternately flashes cA and the 2 digit keypad Press the x key to continue address Enter 2 Receiver Address Enter the 2 digit receiver address 00 30 Alternately flashes rA and the 2 digit receiver Press the x key to continue address Enter 4 House ID Source Enter 1 System to use the House ID Alternately flashes hS and either 1 or 0 programmed into the control panel if RF keypad s and or bi directional device s e Are used on the control panel OR e Neither is used Enter 0 Local to use the House ID programmed into the FA270RF Program Ad
9. ble The keypad will display the next number that can be enrolled i e d3 8 then 2 Wireless Key User Code 8 then 4 Wireless Key Loop Function 8 then 5 Wireless Key On Board Relay Assignment Restore Defaults 1 Restores Defaults Wireless Key Auto Enroll Enter Serial Number pe ee of t When operating the system in High Security mode non encrypted wireless keys will not function Defaulting the FA270RF To restore the FA270RF to the default values perform the following steps Enter the Program mode by pressing the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power The keypad alternately flashes oo and two dashes Press the 9 key The display flashes EE Press the 1 key to restore the default values or press any other key to exit without restoring the default values If you pressed 1 the keypad beeps three 8 times and returns to alternately flashing oo and two dashes If you pressed any other key the keypad will beep two 2 times and return to alternately flashing oo and two dashes Press to exit the FA270RF Program mode Programming Procedure This section is divided into two parts e Programming for an installation WITHOUT local wireless Keys e Programming for an installation WITH local wireless Keys Using the programming procedure WITH local wireless Keys is necessary only if you plan to use wireless keys beyond the control p
10. dress 3 Note If the House ID Source is e System 1 RF keypad and bi directional units MUST match the House ID programmed into the control panel e Local 0 RF keypad and bi directional units MUST match the House ID programmed into the FA270RF Press the key to continue Enter 6 Receiver Enable Enter 1 to enable or 0 to disable Alternately flashes rE and either 1 or O Enable the receiver if RF transmitters or wireless keypads are programmed into the control Note Make sure the number of receivers set for Enable 1 does not exceed the capacity of the control panel Press the key to continue Enter 7 Transmitter Module Enable Enter 1 to enable or 0 to Alternately flashes tE and either 1 or 0 disable Enter 1 if bi directional devices are being used Note If the House ID Source is System and more than one FA270RF is used make sure each of the keypads have the Transmitter Module enabled See Note under House ID Source step 4 Press the key Enter 0 High Security Mode To put the system into High Security mode enter 1 Enter 0 to disable 8 Press the k key to exit the FA270RF Program mode READY or NOT READY Note This is all the FA270RF programming necessary for this application Upon exiting the Program mode the FA270RF alternately flashes Ad the 2 digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps
11. ection Deleting Replacing or Editing Wireless Keys Use the following procedure to delete replace or change any of the programming for a wireless key Display Enter the Program mode by pressing the 1 and 3 keys Alternately flashes oo and two dashes simultaneously for a few seconds within 30 seconds after applying power Enter 5 Wireless Key Editing Enter the device number for the Flashes the device number and a hyphen wireless key you want to edit This must be a device that has its serial number programmed in the FA270RF already To delete the serial number press then press 9 and press x again To exit without deleting the serial number press the key Press the key to continue Once the device number is entered alternately flashes d with the device number and the serial number so wm _ _ ow To change any of the programming for the wireless key perform one fue ae flashes d with the device number of the following steps in the Programming for an Installation WITH and Local Wireless Keys section e For the user code perform step 5 e For the loop functions perform steps 6 and 7 e For the on board relay assignment perform steps 8 to 10 When you have completed editing the wireless keys press the x key twice to exit the Program mode The keypad will display the last number that was enrolled i e d3 Note Upon exiting the Program mode the FA270RF alt
12. ernately flashes Ad the 2 digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps 1 through 3 in the Programming for an Installation Without Local Wireless Keys section TROUBLESHOOTING The following error messages cause the FA270RF to produce rapid beeps for 5 seconds The table below describes the error messages and the corrective actions ae Probable Cause Corrective Action Low battery in a wireless key 1 Replace the battery in the wireless key 2 Replace the transmitter if the wireless key does not have a replaceable battery OC Opencircuit sid Verify that the Data Out wire is connected properly pe ee connection Verify that the control panel is not a First Alert type control panel Check 09 OR FA270RF Receiver isnot 1 Verify that the Data In wire is connected properly Check 100 OR communicating Check inn Another device on the 2 Verify the wiring connections between the control and all other devices keypad terminals is not communicating to the control panel Too many RF zones Verify the number of transmitters programmed into the control panel programmed nn receiver address programmed in the control panel SPECIFICATIONS Physical 6 1 4 H x 4 7 8 W x 1 D Voltage 12VDC es 123 8mm x 25 4mm Current Standby Backlighting on 75mA Wiring Refer to Wiring Table Backlighting and Sounder on 95mA Range 200 nominal Relay Normally Open 1A 28V
13. f and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment LIMITED WARRANTY Honeywell International Inc acting through its Security amp Custom Electronics business Seller 165 Eileen Way Syosset New York 11791 warrants its product s to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the da
14. less key Sa To program a button on the wireless key to control the on board Flashes o relay enter 5 On Board Relay Assignment Enter the loop number of the wireless key 1 4 Enter the relay action 0 no action 1 relay off 2 relay on 3 relay toggles on and off 4 relay closes for 2 seconds Flashing o and the loop number Once the action is entered displays o and alternately flashes the loop number and the relay Note The relay action must be 0 for UL installations action Press the key When all loops have been programmed for the wireless key press the Flashes d followed by the device number PK key The FA270RF automatically displays the next available device number one that does not have a serial number If you want to program additional wireless keys repeat steps 3 through 10 Otherwise press the key This takes you back to the main display which alternately flashes oo and Enter 0 High Security Mode To put the system into High Security Flashes En and 0 alternately OR En and mode enter 1 Enter 0 to disable 1 if the keypad is in high security mode Note Upon exiting the Program mode the FA270RF alternately flashes Ad the 2 digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps 1 through 3 in the Programming for an Installation Without Local Wireless Keys s
15. mode This mode allows you to enable and disable individual local wireless keys useful if e g a user accidentally loses a wireless key Refer to the User Guide for instructions Programming Operations Once you have entered the Program mode you may move to any program address simply by entering the program address number The FA270RF will automatically exit the Program mode if no keys are pressed for 90 seconds While in the Program mode e Pressing the x key stores the information displayed then moves you to the next prompt and the keypad beeps twice e Pressing the key erases the current information and moves you back so you may enter the correct information Enter a program address e g press 1 for Keypad Address 2 for Receiver Address to set the parameters in the FA270RF The following chart lists the program addresses the keypad display and the choices Keypad Address ost Receiver Address 00 300 Program oe 10 House ID Source 1 System 1 System 0 Local Enter Existing Device Number 1 On 0 Off 1 Enable 1 On 0 Off 1 Enable 5 Wireless Key Editing Receiver Enable 7 Transmitter Module Enable Enter 4 Digit User Code Enter Loop Number then Function Loop 2 1 Disarm See Wireless Key Function Chart Loop3 2 Arm Away Loop 4 3 Arm Stay Enter Loop Number then Relay Loop 1 Close for 2 Seconds Action Any Other Key Does Not High Security Modet 1 Enable 0 Disable O Disa
16. of an installation using two FA270RF Keypad Transceivers with 2 Way Wireless Devices e g 5828V on Two Partitions is shown below CONTROL PANEL FA270RF FA270RF 1 2 Settings FA270RF 1 FA270RF 2 Keypad Must be assigned to Partition 1 in the control panel Must be assigned to Partition 2 in the control panel Match Partition 1 Match House ID in House ID in the Wireless Device control panel and House ID in Wireless Device House ID System Source Receiver On Off Enable Transmitter On On Enable PROGRAMMING THE FA270RF The FA270RF is shipped with pre programmed default values Later in these instructions are diagrams showing the wireless keys loops and their default functions Regardless of which wireless key you use even if it is one not shown loops 1 4 are defaulted for all eight devices as shown These values may be changed to suit the installation Entering Program Mode Press the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power The keypad beeps three 3 times and two dashes and two zeroes flash alternately in the upper left hand corner of the display If any other numbers or letters flash in the display press the key Note The keypad will not enter programming mode if the system has been armed before the FA270RF was powered up or down Pressing the 1 and 3 keys 30 seconds or more after applying power allows you to enter the User
17. ou reject the serial number the FA270RF beeps once and returns to the enroll serial number prompt Note A maximum of 8 wireless keys may be enrolled into the FA270RF These wireless keys DO NOT occupy any zones supported by the control If you are finished programming for now press to exit Otherwise continue with step 5 Enter 2 User Code Enter the 4 digit user code for the wireless key Note The user code must be a valid code that is programmed in the control panel Press the key to accept the user code If you are finished programming for now press gt x to exit Otherwise continue with step 6 Enter 4 Loop Functions Enter the loop number 1 4 Note The FA270RF is shipped with the loop functions pre programmed Perform steps 6 through 10 only if it is necessary to change any of the loop functions Close the FA270RF On Board Relay for 2 sec 1 Disarm Loop 3 2 Arm Away Loop 4 3 Arm Stay See the Wireless Key Function Chart below for the choices Entering a number other than the one specified may give unpredictable results Loop 1 Loop 2 Display Alternately flashes hl and a 2 digit number Flashes d with the next available device number followed by four times and then repeats the sequence Alternately flashes d with the device number and the serial number If you accept the serial number the display flashes the device number and a hyphen
18. r to trigger a relay on the control panel a user code must be entered into the FA270RF This user code must also be programmed into the control panel e You must set the House ID in the FA270RF If the House ID source is System the FA270RF uses the House ID programmed in the Control Panel only if you are using RF keypads and or bi directional devices AND the House ID Source is the FA270RF Local FA270RF Application Guide The following guide outlines how to program the wireless keys RF receiver and the House ID in the FA270RF for your installation eran oe rogrammin ions RF keys RF receivers RF keypads and or Program g g P System Control Panel beyond beyond Bi directional Wireless Keys system s system s devices on more Into Receiver House ID capacity capacity than 1 partition Enable Source FATI00 FATZOG FADTORF Tocai 0 FA1420 FA1480 FATAS0P ONTH System T YES YES FA270RF Local 0 FA162C FA168C FA168CPS NO YES Local 0 FAI220CV FA1340C YES YES N O FA270RF OFF 0 Local 0 OFF 0 Local 0 FAQ7ORF OFF 0 Local 0 Two FA270RFs are needed for this application one assigned to partition 1 and one assigned to partition 2 f using an RF keypad on only one partition the FA270RF s partition assignment in panel programming must match the partition If set for Local on a partition control the FA270RF s partition assignment must match the one programmed in the BD device An example
19. right oo si aaa ea Inc
20. te stamp control on the product s or for product s not having a manufacturer s date stamp for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product s which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product s is altered or improperly repaired or serviced by anyone other than Honeywell factory service Connection of any device s to a communicating bus of a Honeywell security system e g keypad bus polling loop other than those manufactured or approved by Honeywell shall void this warranty For warranty service return product s transportation prepaid to Honeywell Factory Service 165 Eileen Way Syosset New York 11791 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGEN