Home

- Oracle Documentation

image

Contents

1. 7 1 Universal HBA Overview us 9 Kit Contents scuri ite 9 Universal HBA Features and Specifications 9 Operating System and Technology Requirements 11 Boot Support sis c sessaccsisssseacasasdel esse see a ET a para spie 12 System Interoperability iii 12 Host Platform Support rrise ar ri 12 Storage Support are ee a nn ee en tee nee en de a eat 13 Switch Supports eskeni men Malin santa tienne nn d tention du did a nn eds 14 Environmental Requirements ie 15 2 Universal HBA Installation Configuration and Removal 17 Observing ESD and Handling Precautions 17 Installing the Hardware iii 18 Y To Prepare for Universal HBA Installation 18 Y To Install the Universal HBA ees 21 Changing the Operating Protocol Mode i 22 Connecting the Optical and Copper Cables 24 Y To Connect Optical Cables e 25 v To Connect Copper Ethernet Cables i 25 Powering on the System c s riiiiiipe eine aperitivo 26 Y To Apply Power to the System 26 Viewing LEDS i cccssicccesssboesassiecsesassboesesssed cnnsstb
2. At 16 Gb s up to 125 meters using 50 125 mm core OM4 fiber Longer lengths are possible at slower data rates For 10 GbE up to 400 meters using 50 125 mm core OM4 fiber For more optical cable specifications see Table 2 1 Two LEDs per channel yellow and green on the front panel as status indicators Power LED Service RequiredLED and a button on the front panel to support hot swap functionality 13 3 watts PCI Express ExpressModule single wide 198 mm x 112 mm x 21 mm Operating System and Technology Requirements The universal HBA requires the OS and technology levels listed in Table 1 2 at minimum TABLE 1 2 Supported Operating System Technology Versions Operating System Technology Supported Versions minimum Oracle Solaris OS Oracle Linux platform Linux OS Microsoft Windows OS Enterprise and Standard Editions WHQL Certified MS Windows MPIO VMware technology Oracle Solaris 10 1 13 for the x86 64 bit platform Patch ID 149623 02 Oracle Solaris 10 1 13 for the SPARC platform Patch ID 149622 02 Oracle Solaris 11 1 for the x86 64 bit platform SRU 6 Oracle Solaris 11 1 for the SPARC platform SRU 6 Oracle Linux 5 9 UEK 2 6 39 400 109 4 at minimum Oracle Linux 6 4 UEK 2 6 39 400 109 4 at minimum Oracle VM 3 2 1 Red Hat Enterprise Linux RHEL 5 9 64 bit RHEL 6 4 64 bit SUSE Linux Enterprise Server SLES 10 U4 SLES 11 U2 Windows Server 2008 SP2 64 bit Windows
3. Emulex Installation Guide July 2015 00 CHAPTER 1 Universal HBA Overview This chapter provides a basic overview of the Sun Storage 16 Gb FC ExpressModule Universal HBA which uses Emulex technology This chapter also describes the various operating systems host platforms storage and infrastructure configurations that support the universal HBA This chapter contains the following sections Kit Contents on page 9 m Universal HBA Features and Specifications on page 9 Operating System and Technology Requirements on page 11 Boot Support on page 12 m System Interoperability on page 12 m Environmental Requirements on page 15 Kit Contents Standard option of the Sun Storage 16 Gb Fibre Channel FC ExpressModule Universal HBA Emulex m Accessing Documentation document China RoHS Material Disclosure document Universal HBA Features and Specifications The Sun Storage 16 Gb FC ExpressModule Universal HBA Emulex marketing part number 7101690 is a standalone PCI Express ExpressModule host bus adapter HBA This HBA is a reconfigurable board that changes its operating protocol mode from a two port 16 Gb FC HBA to a two port 10 GbE CNA based on the optical transcievers and optical cables that you insert and attach to the board at boot time Chapter 1 Universal HBA Overview 9 Universal HBA Features and Specifications The board interfaces an eight lane PCI Express bus with
4. On On Failure in Common Code Module On 1 Fast Blink Normal Link up at 2 GFC legacy compatibility only On 2 Fast Blinks Normal Link up at 4 GFC On 3 Fast Blinks Normal Link up at 8 GFC 28 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 To Apply Power to the System Green LED Yellow LED State On 4 Fast Blinks Normal Link up at 16 GFC On Flashing Not Defined Slow Blink Off Normal link down Slow Blink On Not Defined Slow Blink Slow Blink Not Defined Slow Blink Fast Blink Not Defined Slow Blink Flashing Not Defined Fast Blink Off Not Defined Fast Blink On Not Defined Fast Blink Slow Blink Not Defined Fast Blink Fast Blink Beaconing Fast Blink Flashing Not Defined Note In FC mode for the link rate conditions there is a 1 second pause when the LED is off between each group of fast blinks 2 3 or 4 Observe the LED sequence for several seconds to be sure you have correctly identified the pattern Table 2 3 summarizes the LED indicator combinations and their meanings when the universal HBA is in Ethernet mode Refer to Figure 2 7 to determine the location of the LEDs TABLE 2 3 LED Indicator Combinations for Ethernet Mode Green LED Yellow LED Status Off Off No power or normal link down Off On POST failure or invalid SFP configuration Off On Normal Link up with no activity on the link Blink On Normal Link up with a
5. and click the link to the driver for the appropriate version of Linux 4 Click the driver kit Download icon to copy the driver to a local file system 5 Click the applications kit Download icon to copy the management utilities to a local file system 6 Click each of the manual icons to open the associated user manual 36 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 Installing Software for VMware Technology 7 Install the driver and management applications for Linux as described in the Emulex documentation Installing Software for VMware Technology The universal HBA management applications for VMware technology are available for download at the Oracle support area of the Emulex web site However you must obtain the drivers from the VMware web site V To Install the Universal HBA Software for VMware Technology 1 Goto the Oracle support area of the Emulex web site at http www emulex com downloads oem qualified oracle 2 Click the model number 7101690 of the universal HBA for which you want to install VMware driver and management application software 3 Click the link to the VMware Driver section and click the link to the driver for the appropriate version of VMware 4 From the Description column click the link to the VMware web site and download the driver to a local file system 5 Return to the Oracle support area of the Emulex web site an
6. 30 To Configure the Universal HBA Oracle Solaris on page 31 m To Verify Attached Storage Oracle Solaris on page 31 V To Verify Proper Installation Oracle Solaris Use the cfgadm command to verify proper universal HBA installation If the universal HBA is properly installed and connected you will see output similar to the following cfgadm Ap_Id Type Receptacle Occupant Condition c3 fc connected configured ok c4 fc connected configured ok pcie5 fibre hp connected configured ok 30 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 To Configure the Universal HBA Oracle Solaris Vv To Configure the Universal HBA Oracle Solaris ifthe universal HBA is shown as unconfigured or disconnected use the cfgadm configure Command to configure the universal HBA W To Verify Attached Storage Oracle Solaris Use the cfgadm al command to verify attached storage If the universal HBA is properly installed and storage is connected properly you will see output similar to the following example In this example one port of a universal HBA is connected through a fabric switch to two ports of a disk array cfgadm al Ap_Id Type Receptacle Occupant Condition c3 fc fabric connected configured unknown c3 200600a0b816005e disk connected configured unknown c3 200700a0b816005e disk connected configured unknown c4 fc connected unconfigured unknown pcies fibre hp c
7. Figure 2 6 shows how to connect the universal HBA with a copper cable FIGURE 2 6 Connecting the Copper Cable 2 After the copper cables are connected to the universal HBA insert the other end of the cables into empty SFP cages on any FCoE supported switches Powering on the System This section provides basic instructions on how to apply power to the system For detailed instructions see your system documentation V To Apply Power to the System 1 Verify that the universal HBA is securely installed in the system For more information see Installing the Hardware on page 18 26 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 To Apply Power to the System Verify that the correct copper or optical cables are attached to the universal HBA and to the FC or FCoE devices For more information ssee Connecting the Optical and Copper Cables on page 24 Power on the system as described in the system documentation Observe the light emitting diode LED status for the power on self test POST results as shown in Viewing LEDs on page 27 Each port has a corresponding set of LEDs that provide a visual indication of the operating state Table 2 2 summarizes the LED indicator combinations for FC mode while Table 2 3 summarizes the LED indicator combinations for Ethernet mode Refer to Figure 2 7 to determine the location of the LEDs Viewing LED
8. GbE 2 m 300 m OM2 Multimode 4 GFC 0 5m 150m FC 0 5 meters LC 50 125 micron fiber 500 MHz km bandwidth cable 8 GFC 0 5 m 50 m Ethernet 2 0 meters 16 GFC 0 5 m 35 m 10 GbE 2 m 82 m Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 To Connect Optical Cables Fiber Optic Cable Maximum Length Minimum Length Connector OM1 Multimode 62 5 4 GFC 0 5 m 70 m FC 0 5 meters LC 125 micron fiber 200 MHz km bandwidth cable 8 GFC 0 5 m 21 m Ethernet 2 0 meters 16 GFC 0 5m 15 m 10 GbE 2 m 33 m V To Connect Optical Cables 1 Ensure the transceiver cages have optical transceivers installed in them prior to connecting optical cables FIGURE 2 5 Connecting the Cables 2 Connect the fiber optic cables to the LC connectors on the universal HBA 3 After the fiber optic cables are connected to the universal HBA connect the other end of the cables to the FC or FCoE device V To Connect Copper Ethernet Cables Perform this procedure if you do not plan to install any transceivers in the universal HBA Use any SFP direct attach twin ax copper cables to attach devices to the universal HBA Chapter 2 Universal HBA Installation Configuration and Removal 25 Powering on the System 1 Insert one end of the copper cables into empty SFP cages on the universal HBA Ensure that the cables are fully inserted and secured
9. HBA you want to upgrade you need to do this only once per device EMLXADM Device Management Utility Version 1 08 4 0 Copyright c 2004 2012 Emulex All rights reserved Available Emulex HBA s 1 SFS emlxs0 devices pci 78 0 pci8086 3c04 2 pcil0df e20e 0 fp 0 0 CONNECTED 2 SFS emlxs1 devices pci 78 0 pci8086 3c04 2 pcil0df e20e 0 1 fp 0 0 CONNECTED 3 SFS emlxs10 devices pci 78 0 pci8086 3c0a 3 2 pcil0df e20e 0 fp 0 0 CONNECTED Enter an HBA number or zero to exit 1 Upgrade the firmware on the selected HBA by issuing the following command emlxadm gt download_fw lt full path and name of firmware file gt At the prompt type y to confirm you want to upgrade the firmware A message is displayed upon completion of the upgrade Download may take several minutes Do not interrupt Downloading Done Type q to quit or type hba to select a different universal HBA to update After you have updated all HBAs type q to quit the emlxadm utility and perform a full power reboot of the system Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 00 CHAPTER 4 Known Issues This chapter provides supplementary and workaround information about the universal HBA Specific bug identification numbers are provided for service personnel This chapter contains the following topics m System Hangs When Performing a Hot Plug Operation on pag
10. any programs installed on the hardware and or documentation shall be subject to license terms and license restrictions applicable to the programs No other rights are granted to the U S Government Ce logiciel ou mat riel a t d velopp pour un usage g n ral dans le cadre d applications de gestion des informations Ce logiciel ou mat riel n est pas con u ni n est destin tre utilis dans des applications risque notamment dans des applications pouvant causer des dommages corporels Si vous utilisez ce logiciel ou mat riel dans le cadre d applications dangereuses il est de votre responsabilit de prendre toutes les mesures de secours de sauvegarde de redondance et autres mesures n cessaires a son utilisation dans des conditions optimales de s curit Oracle Corporation et ses affili s d clinent toute responsabilit quant aux dommages caus s par l utilisation de ce logiciel ou mat riel pour ce type d applications Oracle et Java sont des marques d pos es d Oracle Corporation et ou de ses affili s Tout autre nom mentionn peut correspondre des marques appartenant d autres propri taires qu Oracle Intel et Intel Xeon sont des marques ou des marques d pos es d Intel Corporation Toutes les marques SPARC sont utilis es sous licence et sont des marques ou des marques d pos es de SPARC International Inc AMD Opteron le logo AMD et le logo AMD Opteron sont des marques ou des marques d po
11. contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer ex cuter publier ou afficher le logiciel m me partiellement sous quelque forme et par quelque proc d que ce soit Par ailleurs il est interdit de proc der a toute ing nierie inverse du logiciel de le d sassembler ou de le d compiler except a des fins d interop rabilit avec des logiciels tiers ou tel que prescrit par la loi Les informations fournies dans ce document sont susceptibles de modification sans pr avis Par ailleurs Oracle Corporation ne garantit pas qu elles soient exemptes d erreurs et vous invite le cas ch ant a lui en faire part par crit Si ce logiciel ou la documentation qui l accompagne est conc d sous licence au Gouvernement des Etats Unis ou toute entit qui d livre la licence de ce logiciel ou l utilise pour le compte du Gouvernement des Etats Unis la notice suivante s applique U S GOVERNMENT END USERS Oracle programs including any operating system integrated software any programs installed on the hardware and or documentation delivered to U S Government end users are commercial computer software pursuant to the applicable Federal Acquisition Regulation and agency specific supplemental regulations As such use duplication disclosure modification and adaptation of the programs including any operating system integrated software
12. eight lanes supporting two Fibre Channel FC or two Fibre Channel over Ethernet FCoE optical media ports Each independent FC port operates at 16 Gb sec and features 16 8 4 autonegotiation Each FCoE port operates at 10 Gb sec You can configure the following three options 10 GbE FCoE option The version of the card that provides twin ax or copper 10 GbE FCoE ExpressModule Converged Network Adapter functionality No optic modules are installed in this Converged Network Adapter 16 Gb FC optics option The version of the card that has 16 Gb FC optics installed optics marketing part number 7101686 in the SFP connecter of the card providing short wave 16 Gb Fibre Channel ExpressModule Host Bus Adapter functionality 10 GbE FCoE optics option The version of the card that has 10 GbE optics installed optics marketing part number 7101688 in the SFP connector of the card providing short range 10 GbE FCoE ExpressModule Converged Network Adapter functionality See Table 1 1 for a list of the universal HBA features TABLE 1 1 Universal HBA Features and Specification Feature Description PCI connector x8 PCI signaling environment PCI transfer rate maximum PCle specification compliance PCle hot plug and hot swap functionality Number of ports Number of devices supported FCoE full offload in hardware FC bus type external FC transfer rate FC topologies Receive Side Scaling MSI X Solaris Dynamic Reconfigur
13. issuing the stop_ocmanager command located in this installation directory m Oracle Solaris opt ELXocm m Linux usr sbin ocmanager If you do not stop the OneCommandManager process first the hot plug removal might fail or a system panic might occur 2 Either halt the operating system and remove power from the system or prepare the universal HBA for hot plug removal with one of the following The universal HBA Attention ATTN button as described in To Prepare the Universal HBA for Removal Using the Attention ATTN Button on page 32 m The Oracle Solaris OS as described in To Prepare the Universal HBA for Hot Plug Removal Oracle Solaris on page 33 The Windows Server OS using the Safely Remove Hardware menu 3 Remove the universal HBA from the system V To Prepare the Universal HBA for Removal Using the Attention ATTN Button 1 Attach an antistatic strap to your wrist For more information refer to Observing ESD and Handling Precautions on page 17 2 Press and release the Attention ATTN button near the bottom of the universal HBA front panel see Figure 2 7 32 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 To Prepare the Universal HBA for Hot Plug Removal Oracle Solaris cfgadm Ap_Id pcies pcie6 The green OK Power LED near the button will blink for approximately five seconds indicating that the universal HBA is
14. BA into its slot being careful that the tooth on the bottom of the lever does not come into contact with the chassis sheet metal during insertion 5 After the universal HBA is inserted nearly all the way into its slot push the lever back into its fully closed position allowing the lever tooth to insert the universal HBA fully into place Changing the Operating Protocol Mode You can choose to change the operating protocol mode of the Sun Storage 16 Gb FC ExpressModule Universal HBA The operating protocol mode is selected automatically by the firmware based on the types of transceivers that you install following these rules Note The transceivers must be plugged into the HBA before the board is booted The Sun Storage 16 Gb FC ExpressModule Universal HBA does not support changing the operating mode by hot swapping the transceivers 22 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 Changing the Operating Protocol Mode The two modes of operation are Two port 16 Gb FC or Two port 10 GbE CNA one NIC plus one FCoE function per port The board operates with only one valid transceiver plugged into either port with the following behavior Functions continue to be presented as if the universal HBA were a two port board Functions mapped to the empty transceiver cage will be in link down condition The Sun Storage 16 Gb FC ExpressModule Universal HBA r
15. Bus Adapter Emulex Installation Guide July 2015 0 CHAPTER 3 Software Installation After you have completed the hardware installation and powered on the system follow the instructions listed in this chapter for your operating system to install the universal HBA driver and any other required utilities This chapter contains the following sections Driver Software for the Oracle Solaris OS on page 35 Installing Software for the Red Hat and SUSE Linux OSes on page 36 Installing Software for VMware Technology on page 37 Installing Software for the Windows Server 2008 OS on page 37 Configuration and Diagnostic Support on page 38 Upgrading Firmware on page 39 Driver Software for the Oracle Solaris OS Before using the universal HBA update the universal HBA driver software for the Oracle Solaris OS with the following SRU version or patch at minimum m Oracle Solaris 11 1 OS for the SPARC and x86 platforms SRU 6 Oracle Solaris 10 1 13 OS for the SPARC platform Patch 149622 02 Oracle Solaris 10 1 13 OS for the x86 platform Patch 149623 02 The latest available SRU versions and patches are located at http support oracle com Oracle Solaris Diagnostic Support Diagnostic support for the universal HBA is included in the Oracle VTS software The Oracle VTS software is available for download at http support oracle com For information about the Oracle VTS software se
16. Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 To Prepare for Universal HBA Installation If the universal HBA contains optical transceivers and for any reason you need to remove and reinsert a transceiver follow these steps Caution This is a delicate operation Take care not to damage the optical transceiver Note Only supported transceivers are allowed If invalid or unapproved transceivers are plugged in and the board is booted the links will not be allowed to come up For more information about supported transceivers see Changing the Operating Protocol Mode on page 22 The universal HBA uses different types of optical transceivers see Universal HBA Features and Specifications on page 9 Figure 2 1 shows an example of one transceiver type with the bail handle in the locked position FIGURE 2 1 Typical Optical Transceiver a To remove a transceiver remove the dust plug pull the bail handle out and down to release the latch and gently pull the transceiver out Do not force it After the latch is released the transceiver slides out easily Figure 2 2 shows a transceiver with the latch released bail extended and another transceiver latched in place Chapter 2 Universal HBA Installation Configuration and Removal 19 To Prepare for Universal HBA Installation FIGURE 2 2 Releasing the Latch on an Optical Transceiver Figure 2 3 shows an extracted
17. FCOE Switch Cisco 9148 FC switch 8 Gb FC m Cisco MDS 9513 Note The universal HBA has been verified to function with Cisco 5xxx switches however Oracle Services does not support customers with questions or issues about these switches Direct all inquiries about the use of Cisco 5xxx switches to Cisco Systems Environmental Requirements The universal HBA environmental requirements are listed in Table 1 5 TABLE 1 5 Universal HBA Environmental Requirements Specification Operating Non Operating Temperature 0 to 55 C non condensing 20 C to 85 C non condensing Relative 10 to 90 RH non condensing 22 C 5 to 95 RH non condensing 22 C max wet bulb Humidity RH max wet bulb Altitude 3200 m 12 200 m Vibration 0 25 g in all axes 5 500 Hz sine 1 2 g in all axes 5 500 Hz sine Shock 5 5 g 11 ms half sine 33 g 11 ms half sine Chapter 1 Universal HBA Overview 15 16 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 00 CHAPTER 2 Universal HBA Installation Configuration and Removal This chapter describes the tasks required to install configure and remove the universal HBA For detailed instructions refer to your system installation or service manual This chapter contains the following sections Observing ESD and Handling Precautions on page 17 Installing the Hardware on page 18 Changing the Operating Prot
18. Install the Software for the Windows Server 2008 OS 38 Configuration and Diagnostic Support e 38 Upgrading Firmware ss ccc pini Eee ira 39 v To Upgrade Firmware Using the OneCommand Manager GUI 39 v To Upgrade Firmware Using the OneCommand Manager CLI 41 4 Known Issues piocn ile live flat ent nt tue lated Lie 43 System Hangs When Performing a Hot Plug Operation neers 43 Link Aggregation Control Protocol LACP Cannot Be Used In Certain Conditions uil iaia ia lo 45 SAN Boot Fails Via Direct Attached Storage on Oracle SPARC Systems 45 GIOSSANY tien iano A ire ai 47 6 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 Using This Documentation m Overview Describes how to troubleshoot and maintain the universal host bus adapter m Audience Technicians system administrators and authorized service providers Required knowledge Advanced experience troubleshooting and replacing hardware Product Documentation Library Documentation and resources for this product and related products are available at http docs oracle com cd E24648 01 index html Feedback Provide feedback about this documentation at http www oracle com goto docfeedback Using This Documentation Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter
19. Oracle s StorageTek 9980 9985 9985V storage system m Oracle s StorageTek 9990 9990V storage system Tape Storage Support The universal HBA supports connecting through a supported switch to the following tape storage Oracle s StorageTek SL24 Tape Autoloader Oracle s StorageTek SL48 Tape Library Oracle s StorageTek SL500 Modular Library Oracle s StorageTek L1400 Tape Library Oracle s StorageTek SL3000 Modular Library Oracle s StorageTek SL8500 Modular Library m Oracle s StorageTek Virtual Tape Library VTL Value and VTL Value Plus Oracle s StorageTek T10000B T10000C Oracle s StorageTek 9840C tape drive Oracle s StorageTek 9940B tape drive Oracle s StorageTek 9840D tape drive a IBM LTO4 a IBMLTO5 Unified Storage The universal HBA supports connecting through a supported switch to the following unified storage Oracle s Sun Storage 7110 7210 7310 7410 System Target mode only Oracle s Sun ZFS Storage 7120 7320 7420 7720 System Switch Support The universal HBA supports the following Fibre Channel switches Brocade 8000 FCoE TOR Switch Brocade 300 FC Switch 14 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 Environmental Requirements Brocade 5100 5300 FC Switch Brocade 6510 FC Switch 16 g Brocade DCX DCX 4S DCX8510 FC Switch Cisco Nexus 5010 Cisco Nexus 5020 FCoE TOR Switch Cisco 5548 FC
20. PROM electrically erasable programmable read only memory ESD electrostatic discharge F FC Fibre Channel FCoE Fibre Channel over Ethernet G Gb gigabit GbE gigabit Ethernet GUI graphical user interface H HBA host bus adapter l IEEE Institute of Electrical and Electronics Engineers IP internet protocol iSCSI internet Small Computer System Interface L LED light emitting diode 48 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 RoHS LP LUN MAC MSI X NIC OFC OS PCI PCIe POST RoHS low profile logical unit number media access control message signaled interrupts extended networking interface card optical fiber cable operating system Peripheral Component Interconnect Peripheral Component Interconnect Express power on self test random access memory relative humidity Restriction of Hazardous Substances Directive Glossary 49 SAN S SAN storage area network SFP enhanced small form factor pluggable transceiver SR short range SW short wave T TOR top of rack U UCNA universal converged network adapter V VLAN virtual local area network W WWN world wide name WWPN world wide port name 50 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015
21. Server 2008 R2 including SP1 64 bit Windows Server 2012 64 bit VMware ESXi 5 0 5 1 Chapter 1 Universal HBA Overview 11 Boot Support Boot Support FC SAN and FCoE SAN booting through the universal HBA is supported as listed in Table 1 3 TABLE 1 3 Universal HBA Boot Support Operating System Technology FC SAN Boot Support FCoE SAN Boot Support Oracle Solaris 10 1 13 Yes No Oracle Solaris 11 1 Yes No Oracle Linux 5 9 No No Oracle Linux 6 4 Yes No Oracle VM 3 2 1 Yes No RHEL 5 9 Yes Yes RHEL 6 4 Yes Yes SLES 10 U4 Yes Yes SLES 11 U2 Yes Yes Windows Server 2008 SP2 Yes Yes Windows Server 2008 R2 Yes Yes Windows Server 2012 Yes Yes tWhile using the Driver Update disk during the installation process Driver Update is available at the Oracle support area of the Emulex web site http www emulex com downloads oem qualified oracle System Interoperability This section provides information about selected platforms and storage that are compatible with the heterogeneous FC network design of the universal HBA This section contains the following topics Host Platform Support on page 12 Storage Support on page 13 Switch Support on page 14 Host Platform Support The universal HBA is supported by the platforms listed in Table 1 4 For up to date information see your system Product Notes and web pages For information about supported OS technology versions see Table 1 2 12
22. Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide For HBA Model 7101690 Part No E24463 06 July 2015 ORACLE Part No E24463 06 Copyright 2014 2015 Oracle and or its affiliates All rights reserved This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws Except as expressly permitted in your license agreement or allowed by law you may not use copy reproduce translate broadcast modify license transmit distribute exhibit perform publish or display any part in any form or by any means Reverse engineering disassembly or decompilation of this software unless required by law for interoperability is prohibited The information contained herein is subject to change without notice and is not warranted to be error free If you find any errors please report them to us in writing If this is software or related documentation that is delivered to the U S Government or anyone licensing it on behalf of the U S Government then the following notice is applicable U S GOVERNMENT END USERS Oracle programs including any operating system integrated software any programs installed on the hardware and or documentation delivered to U S Government end users are commercial computer software pursuant to the applicable Federal Acquisition Regulation and agency specific su
23. Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 System Interoperability TABLE 1 4 Platform Support Platform Supported OS Technology Oracle s SPARC Servers SPARC T4 4 Oracle Solaris SPARC T5 1B Oracle Solaris Oracle Netra SPARC T5 1B Oracle Solaris Oracle s x86 Servers Netra X3 2 Legacy BIOS mode only no Oracle Solaris Windows Linux VMware UEFI support Sun Server X4 2B Oracle Solaris Windows Linux VMware Storage Support This section lists the supported arrays and tape storage that can connect to the universal HBA through a supported switch see Switch Support on page 14 This section contains the following topics Array Support on page 13 Storage System Support on page 13 Tape Storage Support on page 14 Unified Storage on page 14 Array Support The universal HBA supports connecting through a supported switch to the following arrays Oracle s Sun Storage 2540 M2 Oracle s Sun Storage 6140 Oracle s Sun Storage 6180 Oracle s Sun Storage 6190 Oracle s Sun Storage 6540 Oracle s Sun Storage 6590 Oracle s StorageTek 6580 6780 with 8 Gb s FC Host Interface cards Storage System Support The universal HBA supports connecting through a supported switch to the following storage systems Chapter 1 Universal HBA Overview 13 System Interoperability Oracle s Pillar Axiom 600 storage system m
24. ation Diagnostic Support Boot support RAM BIOS ROM NVRAM External connectors PCI Express x8 8 active lanes PCI Express Generation Three 8 GT s x8 PCI Express Card Version 3 0 Specification Supported Two 126 devices per FC loop not supported at 16 Gb 510 devices in Fabric mode Meets requirement Fiber optic media short wave laser multi mode fiber 400 M5 SN S 16 Gb s Switched fabric N_Port arbitrated loop NL_Port FC AL support for 4 G 8 G only and point to point N_Port Supported Supported Supported Provided by Oracle VTS software Ethernet FCoE and FC for all supported operating systems For more information about boot support for the universal HBA see Table 1 3 1 5 MB parity protected per port One 32 MB flash ROM field programmable One 32 KB EEPROM m Sun Storage 10 GbE FCoE optics SR Emulex part 7101688 m Sun Storage 16 Gb FC optics SR Emulex part 7101686 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 Operating System and Technology Requirements Feature Description Small form factor pluggable SFP Maximum FC cable length LED indicators Maximum power consumption Form Factor m SFP direct attach copper DAC twinaxial twin ax cables from the supported switch manufacturers listed in Switch Support on page 14 Supporting options with short range short wave and twin ax cabling
25. being prepared for removal If you want to cancel the operation press the Attention ATTN button again before the LED stops blinking After the OK Power LED goes dark remove the universal HBA as described in To Remove the Universal HBA Hardware on page 33 To Prepare the Universal HBA for Hot Plug Removal Oracle Solaris If you want to remove the universal HBA without first halting the operating system and removing power from the associated system prepare the universal HBA for removal as follows Use the cfgadm command to identify the universal HBA to be removed Type Receptacle Occupant Condition fibre hp connected configured ok fibre hp connected configured ok Use the cfgadm c unconfigure Command to unconfigure the attachment point ID Ap_Id for the universal HBA Use the cfgadm c disconnect command to prepare the universal HBA for removal A flashing OK Power LED indicates that the universal HBA is being prepared for removal A dark OK Power LED indicates that the universal HBA is ready to be removed as described in To Remove the Universal HBA Hardware on page 33 To Remove the Universal HBA Hardware Disconnect all cables Press the universal HBA latch to disengage the universal HBA and then pull forward and down to eject it You can now remove the universal HBA Chapter 2 Universal HBA Installation Configuration and Removal 33 34 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host
26. bre Channel FC mode in an Oracle SPARC Enterprise T4 1 or T4 2 system and a direct connection is made with a fiber optic cable from the universal HBA to a storage device the system might not detect any bootable volume on that storage device When you attempt to boot using the storage device an error message is displayed ERROR boot read fail Workaround Do not boot from a bootable volume on a storage device if that storage device is directly connected to the universal HBA Instead if you want to boot using the storage attached to the universal HBA use a SAN topology that includes one or more FC switches connected in the path between the universal HBA and the target storage device You can use a direct connection to storage as long as the system is booting the Oracle Solaris operating system from a boot device that is not connected directly to the universal HBA Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 ASIC BIOS C CENELEC CLI CNA DAC DAS DCR DHHS Glossary application specific integrated circuit Basic Input Output System European Committee for Electrotechnical Standardization command line interface converged network adapter direct attach copper direct attached storage direct connecting receptacle Department of Health and Human Services Glossary 47 ECC E ECC Error Checking and Correction EE Enhanced Ethernet EE
27. bre Channel Host Adapter rev 10 Use the cd command to navigate to the directory where slots are listed and issue the ls command to review the available PCI devices cd sys bus pci slots ls From the slots that are displayed map the listed slots to the device IDs that were listed in Step 2 Verify the power status of the slots by issuing the cat slot device ID power command for each available slot cat 0000 08 00 0 power 1 cat 0000 08 00 1 power 1 In this example the output of 1 indicates the slots are powered up Issue the echo 0 gt slot device ID power command to power down the slot that you want to use for hot plugging Verify that you have powered down the slot by issuing the ls command ls 0000 08 00 1 In this example you can see the first slot is powered down because only the second slot is listed Perform the hot plug operation by inserting the card into the slot that you powered down Issue the cd command to navigate to the directory of the powered down slot and then issue the echo 1 gt slot device ID power command to power up the slot echo 1 gt 0000 08 00 0 power Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 Link Aggregation Control Protocol LACP Cannot Be Used In Certain Conditions 10 To verify that the slot is powered up issue the Ls command ls 0000 08 00 0 0000 08 00 1 The hot plug procedu
28. ctivity on the link Note In Ethernet mode in order to tell the difference between a POST failure and a link up condition with no activity you must remove the SFP transceiver or copper cable If the LED pattern persists it is a POST failure condition If the yellow LED was indicating a link up with no activity condition it will turn off which indicates a normal link down Table 2 4 lists the OK Power LED states TABLE 2 4 OK Power LED States LED State Meaning Removal Status Off No power to the HBA Removal is permitted or the HBA must be configured Chapter 2 Universal HBA Installation Configuration and Removal 29 Testing the Installation LED State Meaning Removal Status Flashing Hot plug in process Removal is not permitted Solid green HBA is properly configured Removal is not permitted POST Results Power on self test POST is the default mode of self test for the Sun Storage 16 Gb FC ExpressModule Universal HBA No jumpers or connectors are necessary for this test to run These tests perform a quick confidence level check of the universal HBA before running the operational software At a minimum the following tests are performed by POST Flash boot image checksum test Internal ASIC RAM tests for proper ECC and parity operation NL Port loopback test Testing the Installation This section contains the following topics To Verify Proper Installation Oracle Solaris on page
29. d from the Download column click the applications kit link to copy the management applications to a local file system 6 From the Documentation column click each of the manual links to open the associated user manual 7 Install the driver and management applications for VMware as described in the Emulex documentation Installing Software for the Windows Server 2008 OS The universal HBA driver and applications kits for the Windows Server 2008 OS are available for download at the Oracle support area of the Emulex web site Chapter 3 Software Installation 37 To Install the Software for the Windows Server 2008 OS vy To Install the Software for the Windows Server 2008 OS Go to the Oracle support area of the Emulex web site at http www emulex com downloads oem qualified oracle Click the model number 7101690 of the universal HBA for which you want to install Windows Server 2008 driver software Click the link to the Windows Driver section and do one of the following Locate the driver kit and applications kit for the appropriate version of Windows m f available locate the Onelnstall package which contains all drivers and applications for Windows Do one of the following Click Download next to the driver kit to copy the driver to a local file system Click Download next to the Onelnstall package to copy the Onelnstall package to a local file system and skip to Step 6 Click Download next to th
30. depassdssseasssesensstsaievansa odes 27 Testing the Installation sise ire ge balia Talon d tails 30 Y To Verify Proper Installation Oracle Solaris 30 Y To Configure the Universal HBA Oracle Solaris 31 Y To Verify Attached Storage Oracle Solaris 31 Configuring the Universal HBA for Hot Plug Operation 31 Contents Y To Configure the Universal HBA for Hot Plug Operation 31 Removing the HardWare hai 32 Y To Prepare the Universal HBA for Removal Using the Attention ATTN Button gola aa men rer aiar 32 Y To Prepare the Universal HBA for Hot Plug Removal Oracle Solaris 33 Y To Remove the Universal HBA Hardware 33 3 Software Installation i ele Aaa 35 Driver Software for the Oracle Solaris OS ii 35 Oracle Solaris Diagnostic Support 35 Installing Software for the Red Hat and SUSE Linux OSes eee ee eee 36 Y To Install the Universal HBA Software for the Linux OS 36 Installing Software for VMware Technology 37 w To Install the Universal HBA Software for VMware Technology 37 Installing Software for the Windows Server 2008 OS 37 Y To
31. e 43 Link Aggregation Control Protocol LACP Cannot Be Used In Certain Conditions on page 45 m SAN Boot Fails Via Direct Attached Storage on Oracle SPARC Systems on page 45 System Hangs When Performing a Hot Plug Operation Bug 15811563 Conditions m System Platform All supported systems using the Oracle Unbreakable Linux operating system m Operating Protocol Mode of Universal HBA FC CNA m Environment Universal HBA connected directly to supported storage Issue If you are attempting a hot plug operation and the universal HBA is installed in a system that is running the Oracle Unbreakable Linux OS you might encounter a system hang This is due to the method in which you are performing the hot plug operation Workaround Perform hot plug procedures for the Linux OS as follows 1 Ata terminal window issue the modprobe fakephp command to load the hot plug driver on your system Chapter 4 Known Issues 43 System Hangs When Performing a Hot Plug Operation 44 After you load the hot plug driver on your system you will see slots listed in the sys bus pci slots directory Review the available Emulex PCI device IDs by issuing the lspci command This command lists the devices that are available for hot plugging lspci grep i Emulex 08 00 0 Fibre Channel Emulex Corporation Lancer X LightPulse Fibre Channel Host Adapter rev 10 08 00 1 Fibre Channel Emulex Corporation Lancer X LightPulse Fi
32. e applications kit to copy the management application to a local file system Click each of the manual icons to open the associated user manual Install the driver and management applications for the Windows OS as described in the Emulex documentation Configuration and Diagnostic Support For Oracle Solaris Linux VMware and Windows systems use the OneCommand Manager application graphical user interface GUI or the OneCommand Manager application command line interface CLI applications to configure the universal HBA These applications provide support to do the following Discover local and remote hosts HBAs targets and LUNs Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 Upgrading Firmware m Reset HBAs m Set HBA driver parameters m Update firmware m Enable or disable the system BIOS Run diagnostic tests on HBAs Manage out of band HBAs m Manage local and in band remote HBAs For detailed information about performing any of these functions through the OneCommand Manager applications see the Emulex OneCommand Manager application documentation located at the Oracle support area of the Emulex web site http www emulex com downloads oem qualified oracle Upgrading Firmware This section provides basic instructions on how to update universal HBA firmware using the OneCommand Manager graphical user interface GUI and command line inter
33. e the Oracle VTS documentation at http docs oracle com cd E19719 01 index html Chapter 3 Software Installation 35 Installing Software for the Red Hat and SUSE Linux OSes For information about diagnostic options using the OneCommand Manager utilities see Configuration and Diagnostic Support on page 38 The emlxtest utility in Oracle VTS supports the following functions Connectivity verification Firmware version and checksum test Self test Loopback tests External all universal HBAs FC mode only present in the system Internal single bit Internal 10 bit Mailbox Installing Software for the Red Hat and SUSE Linux OSes Before using the universal HBA check for the latest drivers at the Oracle support area of the Emulex web site For diagnostic support you might need to rebuild the Linux driver Before rebuilding the drivers for Linux you must have the required Linux OS installed on the hard disk The driver and utilities are available for download at the Oracle support area of the Emulex web site V To Install the Universal HBA Software for the Linux OS 1 Goto the Oracle support area of the Emulex web site at http www emulex com downloads oem qualified oracle 2 Click the model number 7101690 of the universal HBA for which you want to install Linux driver software and management applications 3 Click the link to the Linux Driver section locate the driver you want to install
34. eboot and not an Oracle Solaris FAST reboot which is insufficient for this operation m If the last known good mode of a board was Converged Network Adapter and the board is booted with one 16 Gb FC transceiver and one 10 GbE transceiver the board continues to present two NIC and two FCoE functions but only the NIC and FCoE functions mapped to the port with the 10 GbE transceiver have an operational link If the universal HBA is in this mode you must change the incorrect transceiver and perform a full power reboot of the board to make the second port operational This must be a full power reboot and not an Oracle Solaris FAST reboot which is insufficient for this operation Only supported transceivers are allowed If invalid or unapproved transceivers are plugged in and the board is booted the links will not be allowed to come up The universal HBA supports the following transceivers 10 GbE optical Short Range SR Optics Module optics marketing part number 7101688 for Sun Storage 10Gb FCoE optics SR Emulex Chapter 2 Universal HBA Installation Configuration and Removal 23 Connecting the Optical and Copper Cables 16 Gb FC optical Short Wave SW Optics Module optics marketing part number 7101686 for Sun Storage 16Gb FC optics SR Emulex 10 GbE copper direct attach cables Any cable provided with a switch that is supported by the universal HBA For information about supported switches see Switch S
35. etains its last known operating state when it boots If an invalid combination of transceivers is plugged into the HBA ports and the board is booted the universal HBA will return to that last known good operating mode Thus the behavior of the board for an invalid configuration depends on the prior configuration as follows The default operating mode is two port 16 Gb FC If no valid transceivers are plugged in the universal HBA will remain in this default mode when booted If one or two valid 16 Gb FC transceivers are plugged in and the board is booted the universal HBA operates in FC mode If invalid transceivers are then plugged in and the board is rebooted the universal HBA remains in FC mode but the links are down If one or two valid 10 GbE transceivers are plugged in and the board is booted the universal HBA operates in Converged Network Adapter mode If invalid transceivers are then plugged in and the board is rebooted the universal HBA remains in Converged Network Adapter mode If the last known good mode of a board was FC and the board is booted with one 16 Gb FC transceiver and one 10 GbE transceiver the board continues to present two FC functions but only the one mapped to the port with 16 Gb FC transceiver has an operational link If the universal HBA is in this mode you must change the incorrect transceiver and perform a full power reboot of the board to make the second port operational This must be a full power r
36. face CLI For detailed information see the Emulex OneCommand Manager application documentation located at the Oracle support area of the Emulex web site http www emulex com downloads oem qualified oracle If the universal HBA is in the CNA operating protocol mode and is installed in a system running the Oracle Linux UEK or Oracle VM operating systems you must use the elxflash toolkit to update firmware This toolkit and instructions are available at the Oracle support area of the Emulex web site http www emulex com downloads oem qualified oracle If the universal HBA is in a configuration that allows multiple virtual functions note that firmware can only be upgraded in the primary function domain Any attempt to do so ina virtual function domain might cause the system to hang This section contains the following topics To Upgrade Firmware Using the OneCommand Manager GUI on page 39 To Upgrade Firmware Using the OneCommand Manager CLI on page 41 V To Upgrade Firmware Using the OneCommand Manager GUI From the Maintenance or Firmware tab of the OneCommand Manager GUI you can update firmware on local and remote HBAs Chapter 3 Software Installation 39 To Upgrade Firmware Using the OneCommand Manager GUI Before You Begin FIGURE 3 1 Before performing this procedure ensure the following is true The universal HBA driver is installed as described earlier in this chapter The OneCommand Mana
37. ger application is installed and the application is NOT running in read only mode The HBA firmware zip file is downloaded from the Oracle support area of the Emulex web site unzipped and extracted to a folder on a local drive Ifthe universal HBA is already connected to a boot device the system is in a state in which this type of maintenance can be performed 1 O activity on the bus is stopped Cluster software or any other software that relies on the universal HBA to be available is stopped or paused From the OneCommand Manager GUI select Host or Fabric view In the discovery tree select the universal HBA for which you want to upgrade firmware Select the Maintenance or Firmware tab and click Download Firmware If the warning screen appears click Yes The Firmware Download dialog box is displayed Firmware Download Dialog Box 5 From the Firmware Download dialog box navigate to the unzipped extracted firmware file that you want to use for the upgrade 40 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 To Upgrade Firmware Using the OneCommand Manager CLI You can navigate to the firmware image by clicking Browse or by typing the path to the file in the Firmware File field in the dialog box After you have found the file and it is populated in the Firmware File field click Start Download A warning dialog box is displayed On
38. he following general steps in the order listed in this section To Prepare for Universal HBA Installation on page 18 To Install the Universal HBA on page 21 Connecting the Optical and Copper Cables on page 24 Powering on the System on page 26 To Verify Proper Installation Oracle Solaris on page 30 V To Prepare for Universal HBA Installation 1 Record the IEEE address World Wide Name WWN and serial number of the universal HBA Each universal HBA is shipped with several numbers clearly marked on the board These numbers indicate the following m IEEE Address World Wide Name WWN Serial number The IEEE address is a unique 64 bit identifier that you use when configuring your system The FC industry uses the World Wide Name WWN derived from the IEEE address for FC connectivity If the adapter has two ports there are two IEEE addresses and two WWNs Use the serial number when communicating with Oracle Service 2 Attach an antistatic strap to your wrist Refer to Observing ESD and Handling Precautions on page 17 3 Refer to your system installation or service manual to determine an appropriate ExpressModule slot in which to install the universal HBA 4 Remove power from the system if hot plugging is not supported on the system To see if your system supports hot plugging hot swapping of PCIe adapter cards refer to your system documentation 18 Sun Storage 16 Gb Fibre
39. ocol Mode on page 22 Connecting the Optical and Copper Cables on page 24 Powering on the System on page 26 Testing the Installation on page 30 Configuring the Universal HBA for Hot Plug Operation on page 31 Removing the Hardware on page 32 Observing ESD and Handling Precautions Caution Damage to the universal HBA can occur as the result of improper handling or electrostatic discharge ESD Always handle the universal HBA with care to avoid damage to electrostatically sensitive components To minimize the possibility of ESD related damage use both a workstation antistatic mat and an ESD wrist strap You can get an ESD wrist strap from any reputable electronics store or from Oracle as part number 250 1007 Observe the following precautions to avoid ESD related problems Leave the universal HBA in its antistatic bag until you are ready to install it in the system Always use a properly fitted and grounded wrist strap or other suitable ESD protection when handling the universal HBA and observe proper ESD grounding techniques Hold the universal HBA by the carrier not by the connectors Chapter 2 Universal HBA Installation Configuration and Removal 17 Installing the Hardware m Place the universal HBA on a properly grounded antistatic work surface pad when it is out of its protective antistatic bag Installing the Hardware The hardware installation process involves t
40. onnected configured ok If the universal HBA is shown as unconfigured or disconnected see To Configure the Universal HBA Oracle Solaris on page 31 Configuring the Universal HBA for Hot Plug Operation Follow the procedure in this section to configure the universal HBA for hot plug operation Y To Configure the Universal HBA for Hot Plug Operation Locate the green OK Power LED indicator near the bottom of the universal HBA front panel as shown in Figure 2 7 The OK Power LED indicator status is shown in Table 2 4 If the green OK Power indicator is not illuminated briefly press the Attention ATTN button near the bottom of the universal HBA front panel Chapter 2 Universal HBA Installation Configuration and Removal 31 Removing the Hardware The green OK Power LED will blink for approximately five seconds and then remain on indicating that the universal HBA is properly configured 3 To cancel the operation press the Attention ATTN button again before it stops blinking Removing the Hardware The following procedure describes how to remove the universal HBA if you need to do so for any reason For detailed removal instructions refer to your system documentation The hardware removal process involves these general steps 1 If you plan to perform a hot plug removal and Emulex OneCommandManager is in use in your environment stop the OneCommandManager process prior to attempting the hot plug removal by
41. pplemental regulations As such use duplication disclosure modification and adaptation of the programs including any operating system integrated software any programs installed on the hardware and or documentation shall be subject to license terms and license restrictions applicable to the programs No other rights are granted to the U S Government This software or hardware is developed for general use in a variety of information management applications It is not developed or intended for use in any inherently dangerous applications including applications that may create a risk of personal injury If you use this software or hardware in dangerous applications then you shall be responsible to take all appropriate fail safe backup redundancy and other measures to ensure its safe use Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications Oracle and Java are registered trademarks of Oracle and or its affiliates Other names may be trademarks of their respective owners Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc AMD Opteron the AMD logo and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices UNIX is a registered trademark of The Open Group This software or ha
42. rdware and documentation may provide access to or information about content products and services from third parties Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third party content products and services unless otherwise set forth in an applicable agreement between you and Oracle Oracle Corporation and its affiliates will not be responsible for any loss costs or damages incurred due to your access to or use of third party content products or services except as set forth in an applicable agreement between you and Oracle Documentation Accessibility For information about Oracle s commitment to accessibility visit the Oracle Accessibility Program website at http www oracle com pls topic lookup ctx acc amp id docacc Access to Oracle Support Oracle customers that have purchased support have access to electronic support through My Oracle Support For information visit http www oracle com pls topic lookup ctx acc amp id info or visit http www oracle com pls topic lookup ctx acc amp id trs if you are hearing impaired R f rence E24463 06 Copyright 2014 2015 Oracle et ou ses affili s Tous droits r serv s Ce logiciel et la documentation qui l accompagne sont prot g s par les lois sur la propri t intellectuelle Ils sont conc d s sous licence et soumis des restrictions d utilisation et de divulgation Sauf stipulation expresse de votre
43. re is completed without a system hang As an alternative you can also use the Attention button to perform hot plug hot unplug operations as follows To perform a hot unplug operation Press the Attention button on the HBA and wait The OK LED will blink for 5 seconds and then remain off To perform a hot plug operation Press the Attention button on the HBA and wait The OK LED will blink for 5 seconds and and then remain on In the event you would like to cancel an Attentionn button hot plug hot unplug operation press the Attention button again after pressing the button to initiate the operation Link Aggregation Control Protocol LACP Cannot Be Used In Certain Conditions Bug 18707752 Conditions m System Platform All supported systems using the Oracle Solaris driver m Operating Protocol Mode of Universal HBA FC CNA Environment Universal HBA connected directly to supported storage Issue LACP cannot be used on the same port as FCoE or iSCSI Workaround None SAN Boot Fails Via Direct Attached Storage on Oracle SPARC Systems Bug 15809064 Chapter 4 Known Issues 45 SAN Boot Fails Via Direct Attached Storage on Oracle SPARC Systems 46 Conditions m System Platform Oracle SPARC systems m Operating Protocol Mode of Universal HBA FC Environment Universal HBA connected directly to supported storage Boot Method SAN boot via the universal HBA Issue When the universal HBA is in Fi
44. s Through the openings in the mounting bracket of the universal HBA you can view green and yellow LEDs for each port and you can view the Service Required and OK Power LEDs The green LED near each port indicates firmware operation and the yellow LED near each port indicates port activity or link speed Each port has a corresponding set of green and yellow LEDs as shown in Figure 2 7 At the bottom of the universal HBA mounting bracket you ll see the OK Power and Service Required LEDs plus an Attention ATTN button Chapter 2 Universal HBA Installation Configuration and Removal 27 To Apply Power to the System FIGURE 2 7 290090 0 LHOd a a e CECE LIFEFEEE 140Od l 006S ee Q 6666666666 66666660 eeee 3 2 ORO d RALLIA A rererere esseeeesse fe Be L LEDs and Attention ATTN Button Each port has a corresponding set of LEDs that provide a visual indication of the operating state Table 2 2 summarizes the LED indicator combinations and their meanings when the universal HBA is in FC mode Refer to Figure 2 7 to determine the location of the LEDs TABLE 2 2 LED Indicator Combinations for FC Mode Green LED Yellow LED State Off Off Boot failure Dead board Off On POST failure Dead board Off Slow Blink Boot failure after POST Off Fast Blink Not Defined Off Flashing POST processing in progress On Off Failure in Common Code Module
45. s es d Advanced Micro Devices UNIX est une marque d pos e d The Open Group Ce logiciel ou mat riel et la documentation qui l accompagne peuvent fournir des informations ou des liens donnant acc s des contenus des produits et des services manant de tiers Oracle Corporation et ses affili s d clinent toute responsabilit ou garantie expresse quant aux contenus produits ou services manant de tiers sauf mention contraire stipul e dans un contrat entre vous et Oracle En aucun cas Oracle Corporation et ses affili s ne sauraient tre tenus pour responsables des pertes subies des co ts occasionn s ou des dommages caus s par l acc s des contenus produits ou services tiers ou leur utilisation sauf mention contraire stipul e dans un contrat entre vous et Oracle Accessibilit de la documentation Pour plus d informations sur l engagement d Oracle pour l accessibilit la documentation visitez le site Web Oracle Accessibility Program l adresse http www oracle com pls topic lookup ctx acc amp id docacc Acc s au support lectronique Les clients Oracle qui ont souscrit un contrat de support ont acc s au support lectronique via My Oracle Support Pour plus d informations visitez le site http www oracle com pls topic lookup ctx acc amp id info ou le site http ww oracle com pls topic lookup ctx acc amp id trs si vous tes malentendant Contents Using This Documentation
46. the warning dialog box click Yes A status bar shows the progress of the download and the HBA in the discovery tree is displayed in black text when the update is complete Note If the HBA is offline the HBA is displayed in red text in the discovery tree Click Close The Firmware tab displays the upgraded firmware information for the selected HBA Note If the state of the boot code on the board has changed this change is reflected immediately on the Port Information tab To Upgrade Firmware Using the OneCommand Manager CLI This section describes how to update firmware using the OneCommand Manager noninteractive and interactive command line interface CLI Before performing this procedure ensure the prerequisites are met as described in To Upgrade Firmware Using the OneCommand Manager GUI on page 39 Do one of the following m From the noninteractive OneCommand Manager CLI type the following command hbacmd Download lt the WWPN of the HBA gt lt full path and name of firmware file gt From the interactive OneCommand Manager CLI for the Oracle Solaris OS follow these steps a Navigate to the directory containing the emlxadm file path opt EMLXemlxu bin and run the emlxadm utility For example Chapter 3 Software Installation 41 To Upgrade Firmware Using the OneCommand Manager CLI 42 root lt host name gt opt EMLXemlxu bin emlxadm The available HBAs are listed Select the
47. transceiver and another transceiver latched in place FIGURE 2 3 Removing an Optical Transceiver b Observe the electrostatic discharge ESD precautions as described in Observing ESD and Handling Precautions on page 17 and store the transceiver in an ESD safe place 20 Sun Storage 16 Gb Fibre Channel ExpressModule Universal Host Bus Adapter Emulex Installation Guide July 2015 To Install the Universal HBA c Re install the transceiver by sliding it into the housing When the latch engages it clicks d Push the bail back into place e If you do not plan to immediately attach cables to the universal HBA reinstall the dust plug into the transceiver V To Install the Universal HBA After you have performed the steps in To Prepare for Universal HBA Installation on page 18 you can install the adapter in your system 1 Attach an antistatic strap to your wrist Refer to Observing ESD and Handling Precautions on page 17 2 Refer to your system installation or service manual to determine an appropriate ExpressModule slot in which to install the universal HBA 3 Press down on the plastic tab to release the ExpressModule latch and pull the lever out until it is nearly perpendicular to the ExpressModule front panel Chapter 2 Universal HBA Installation Configuration and Removal 21 Changing the Operating Protocol Mode FIGURE 2 4 Pulling Out the Universal HBA Lever 4 Insert the universal H
48. upport on page 14 Connecting the Optical and Copper Cables 24 Depending on how you plan to use the universal HBA you can connect either optical or copper cables to the universal HBA If you plan to change the operating protocol mode of the universal HBA by installing a transceiver connect optical cables If you plan to use the standard universal HBA without installing transceivers connect copper cables Note The universal HBA will not allow normal data transmission on an optical link unless it is connected to another similar or compatible laser product that is multimode to multimode Note The universal HBA will not automatically downgrade to the required FC speed based on cable length if both links are capable of a higher operating speed You must downgrade the speed with the appropriate utility or link errors might occur When using multimode fiber optic cables with short wave lasers ensure that the cables adhere to the specifications listed in Table 2 1 TABLE 2 1 Optical Cable Specifications Fiber Optic Cable Maximum Length Minimum Length Connector OM4 Multi mode 4 GFC 0 5 m 400 m FC 0 5 meters LC 50 125 micron fiber 4700 MHz km bandwidth cable 8 GFC 0 5 m 190 m Ethernet 2 0 meters 16 GFC 0 5 m 125m 10 GbE 2 m 400 m OM3 Multimode 50 125 4 GFC 0 5 m 380m FC 0 5 meters LC micron fiber 2000 MHz km bandwidth cable 8 GFC 0 5 m 150m Ethernet 2 0 meters 16 GFC 0 5 m 100 m 10

Download Pdf Manuals

image

Related Search

Related Contents

Nokia bh-302 Car Stereo System User Manual  設定ガイド - KDDI  USER`S MANUAL - TC  Samsung NXF1 Manuel de l'utilisateur  Le répertoire d`outils pédagogiques - Immigration, asile, accueil et  XPRESS LED  取扱説明書  安全に関するご注意  Version 3.0 Maintenance Release 5  

Copyright © All rights reserved.
Failed to retrieve file