Home

User Manual for VE10EK Serial to Ethernet Converter

image

Contents

1. 3 4 Selected COM Port will be Added Port no s 8 in the picture is only for reference vernier media converters S YirtualSerialPort Console 2 6 1 Hardware Installation fee COMMS Unconnected Command Port s XP Tell me why this testing is important 34 Right Click on the added COM port amp choose Add Net option The snap shots are below 34 In the next screen you are required to insert Network details amp F VirtualSerialPort Console 2 7 0 Remove Net Reconnect d Local Port 30000 Remote Address H2700 Remote Port e1000 MANAS media converters Following screens are the confirmation of the IP selected amp communication established Haix VirtualSerialPort Console VirtualSerialPort Console fee CONS Connecting Command Port 192 166 106 24 65530 Connected TCP Client 192 168 106 24 100 Unconnected TCP Client 192 166 106 24 100 Console Options Port Options Console Option Port Option I7 Auto run when login Send to net delay time ms fo Se JZ Auto run when login Send to net delay time ms fo Se JV Minimize when run Receive from net delay time ms fo _Set_ JV Minimize when run Receive from net delay time ms fo _Set_ Logfile TASC Se Log Fie 7 F ASC Set I7 Loopback mode IV Detect timeout I Loopback mode JV Detect timeout Congratulations The Virtual Com P
2. In addition of IP address and Subnet mask specific device settings can be set through HTTP protocol No special software will be required By pressing Alt Enter or select Device Settings in the Config menu will open a new window in browser to login into the device Alternatively if IP address of the converter is already known you can connect to the converter directly by providing IP address in the URL field of browser EN Exploring Login Py x File Edit View Go Favorites Tools Help gt e gt 8 m a S vib B E l Back Forvard Stop Refresh Home Search Favorites History Channels Fullscreen Mail Print Edit Address E http 61 222 2 30 z Controller Status System time elapsed 01 17 06 ase date Sep 42001 03 42 00 46 2B 2E OF 06 Setup Login Password ss PAStart 4 Aw HEN Exploring Login Bate 1 02 PM 34 Activated IE 34 Key in the IP address of the VE 1OEK hardware that is going to setup frame and press Enter 34 The first Login frame will show up You do not have to key in any Password just press Login 34 If you cannot login it means you have to key in the password 34 If you do not know the password you can run the VEIOEK CONF G exe Reset to reset the setup Note If the domain of the converter is different from the computer running the browser the login page won t appear unless the converter s Gateway Address has been correctly set Login
3. EANES media converters User Manual for VE10EK Serial to Ethernet Converter Index Technical Specifications B n ua Bee 1 Installation Procedure LED Indications Configuration Procedure Configuration through Utility Configuration through HTTP Factory Default setting Communication Port Details Cable Detail amp Terminators Power Supply Virtual Com Port Utility NO me CONNNAND W WN VEIOEK is Serial to Ethernet Converter It is an Interface Converter between Ethernet and RS232 RS485 RS422 devices TECHNICAL SPECIFICATIONS Communication Interfaces OOOO 300 bps to 115 2 Kbps Mechanical Comnectors S PowerSupplyf SSCS Environmental SSCS INSTALLATION PROCEDURE Power ON the device The SYS LED Red will glow and flash Insert RJ45 jack into the RJ45 socket of the converter The LAN LED green will glow Connect the Serial Port Data LED green will blinking UUU When you finish these procedures and LED displays are as shown the hardware is properly installed and On line You can use the Setup Tool VE 10EK Config exe to setup the IP Address Subnet Mask and MAC Address For the advance setup please use the IE or other Browsers Refer to the section below for details MANES media converters LED INDICATIONS SYS Red LED CPU health Flashes once a second Data Red LED While Transmiting amp receiving any signal from network the LED will blink LAN Gre
4. DHCP server automatically otherwise enter manually 3 Gateway address Gateway is a device which connects local network to external network Please type it correctly If there is no Gateway on the network just leave as 0 0 0 0 If DHCP client mode enabled and there is a DHCP Server on the network this field will be assigned by DHCP server automatically 4 Network Link speed Select between 10 100 Auto 5 DHCP client DHCP client mode could be enabled disabled If DHCP enabled there should be a DHCP Server on the network If DHCP disabled IP address Subnet mask and Gateway address should be manually assigned File Edit view Favorites Tools Help Back x a A p Search Ke Favorites C4 gt lt Address http 192 168 106 24 Setup htm v E co ink Controller Setup 80 v Destination IP address socket port ic Tt nt and UDP Auto Update 5 Internet 6 Socket port of HTTP 80 7 Destination IP Address socket port Server s IP address amp Socket port no 8 TCP socket inactive timeout To identify whether the socket is active or dead If there is no any data transferred within the defined timeout period 1 to 99 minutes then it probably a dead socket and the socket will be closed automatically A new connection can be accepted again The timeout period can be set by users to fit different kinds of application 9 Serial I O settings Serial Com port Baud rate Parity Data b
5. Screen Parameters fig 5 above System time elapsed The time elapsed since start of this device Day Hour Minute Second format This information can be useful in identifying reliability of system Firmware release date Ethernet address Unique MAC Media Access Control address Password Factory default is empty However it is not recommended to leave empty in field operation If you cannot login it means you have to key the password If you do not know the password you can turn Off the power and then use any point tip to press Reset button and hold it and turn on the power The password will be reset to the factory default as empty The converter uses the same password protection mechanism commonly used in Windows NT or UNIX If there are more than 3 consecutive failures in password check during login the login function will be disabled for 15 minutes During this 15 minutes period even if you supply a correct password login will not proceed This prevents intruder from finding the password by computer generated program EANES media converters Advance setup frame Parameters Fig 7 amp 8 below 1 IP address If DHCP client mode is enabled and there is a DHCP Server on the network this field will be assigned by DHCP server automatically otherwise enter manually 2 Subnet mask If DHCP client mode is enabled and there is a DHCP Server on the network this field will be assigned by
6. Y DEFAULT SETTING By the chance if you forget to setup password or have made incorrect settings making the converter inoperable there are two ways to reset the setting The following procedures can also be used to reset all settings to factory default Turn Off the power of the converter and Press the reset button of the converter Turn ON the power of the converter and wait for 3 seconds The password will RESET to the factory default empty Log in the web page Press the RESET button of the converter Select the UPDATE button After Tx amp Rx light flashes release the Reset button The password will reset to the factory default empty VE10 EK Default Parameters List IP address 10 0 254 254 Socket port of serial I O 100 s Subnet mask 255 255 0 0 g Gateway address 0 0 0 0 s Network link speed Auto DHCP client Disable Socket port of HTTP setup 80 E Destination IP address socket Port 0 0 0 0 TCP client and UDP Connection Auto TCP socket inactive timeout minutes 10 s Packet mode of serial input Disable s Device ID al Report device ID when connected Disable Setup password EANES media converters COMMUNICATION PORT DETAILS RS232 Port Details of VEIOEK VEILOEK me Male GND s os e DR CABLE DETAILS OF VE10EK For RS232 Side VEIOEK Side COM Port Side SIGNAL of VE10EK SIGNAL of VEIOEK Will Connect to For RS485 2 wire TX of your de
7. en LED When On line the LED will remain on P Green LED When the Power is on the LED will be ON RESET BUTTON Press the Reset button Turn ON the power and wait for 3 seconds Converter will reset to factory default CONFIGURATION OF VE10EK USING TOOL VE10EK CONFIG EXE fe Ethernet Manager a de Ethernet Manager View Config view Config IP Address Subnet Mask MAC Address Device ID Refresh F5 lt ihabt Mock Nat Addres Device ID Exit Alt F4 255 255 6 6 66 61 3C D6 D5 36 192 168 6 16 255 255 0 8 66 61 3C D6 D5 36 Devices detected 1 Devices detected 1 VEIOEK Config Setup Tool is used to detect and setup the VE10EK on the Network When you activate the tool it will detect the installed VE10EK as shown in the Figure 1 The VEIOEK CONFIG Setup Tool can setup only one VEIOEK at a time Please shut down or off line other VEIOEK converters The Default IP address is 10 0 254 254 View Refresh Figure 2 View Exit Figure 2 Note Configuration happens only when the device password is empty VEI0EK CONFIG EXE SETUP TOOL FUNCTIONS Figure 3 appears when you select Config option in fig 2 IP Address setup Subnet Mask setup Key desired values as per network Set IP Address IP Address 192 168 0 10 Subnet Mask 255 255 0 0 Cancel Remark Always run the View Refresh after any changes for confirmation MANES media converters CONFIGURATION THROUGH HTTP IE OR OTHER BROWSERS
8. its Stop bits 10 Interface of serial I O Select RS232 or RS485 RS422 11 Packet mode of Serial input Enabled Disabled If packet mode is enabled the data from UART will be deferred until the input buffer is full or the converter detects a 10 character packet gap and no more characters arrive 12 Device ID User assigned ID number for the converter Available ID is 0 65535 13 Report device ID when connected Enable disable In TCP mode if this parameter is enabled every MANES media converters time when the socket is connected converter will immediately report device ID in the following formats 1 Serial 1 nnnnnA LF CR ii Serial 2nnnnnB LF CR ii Digital I O nnnnnC LF CR Total 8 bytes length where nnnnn is 5 digit device ID assigned by the user Attention If the VEIOEK Gateway address is not same as the computer that is doing the setup then the Login frame will not appear unless the VE1OEK Gateway address is setup same as the computer a a When finished please press Update The ae 60 zacna e Dag Controller updated now restarting frame Bock Seo Rebesh Home Seach Favorite Hato Chanel Fulori Mod a will show Figure 9 When the frame is back to the Login frame which means the advance setup it done you can close the browser Controller updated Now restarting Brant E EAO WD Dries Pare aHa emna E New Connect Bpwinsocd Hy A Exploring PANS IM FACTOR
9. ort is installed P O Box 234911 Dubai UAE Tel 971 4 2955966 Fax 971 4 2955977 E mail sales verniertech net
10. vice D TX of your device TERMINATOR VEIOEK has Terminal resistors built in If the switch 1 amp 2 are set in ON position 120 are connected between the signals POWER SUPPLY 230V AC External Adapter OR 24V DC Powered through 2 Pin screw type connector MANES media converters CONFIGURATION FOR VIRTUAL SERIAL PORT CONSOLE VER 2 7 34 Unzip from VE1OEKConfig Virtual Com Vserport zip in the enclosed CD 34 Double click on required exe File f VirtualSerialPort Console 2 7 0 3 VirtualSerialPort Console Console Options Auto run when login Minimize when run 34 Follow the below screens to install the Virtual Com Port 34 Right Click inside the above screen to get Add the Port Option VirtualSerialPort Console 2 7 0 A Add Port Setting VirtualSerialPort Console COM Port cops Auto Assign Cancel eee aa aaa fo r is m COM7 Unconneqped fommand Bo Add Port oq Remove Port i TCF Client Remote Address i Remote Port anan CTCF Serer Lizten Fort pogi Console Options Port Options Send delay time ms J V Auto run when login end to net delay time ms 0 Set z i Local Port ANNIN V Minimize when run Receive from net delay time ms 0 Set Fase Remote Address I 10 7 Remote Fort 1000 C Loopback mode C Detect timeout l Add Port 34 The following screens below will appear 34 Select Continue Anyway

Download Pdf Manuals

image

Related Search

Related Contents

Section 1: User Manual Section 2: Maintenance Guide PROBLEMS  Pavestone Rumblestone RSK52869 Instructions / Assembly    LG-V940n - B&H Photo Video Digital Cameras, Photography  Recettes de champignons  ドイツへの医療機器輸出に関する諸手続  UG-2832HLBEG04 UG  PS241/PS242  

Copyright © All rights reserved.
Failed to retrieve file