Home

Leica LED3000 / Leica LED5000 User Manual

image

Contents

1. Leica LED3000 Leica LED5000 User Manual Leica LED3000 MCI 60 Leica LED5000 MCI Leica LED3000 Leica LED5000 User Manual Leica LED5000 MCI 61 About the Leica LED5000 MCI Leica LED5000 MCI The expert for oblique illumination The Leica LED5000 MCI for Multi Contrast Illumination is a one of a kind lighting solu tion for applications in which until now goose neck illuminators had been used The flat angle of the oblique incident light creates a particu larly high contrast for viewing the specimen allowing the user to detect minute unevenness and faults e g scratches and dust particles In contrast to the goose neck illuminator the settings of the Leica LED5000 MCI are fully reproducible Leica LED3000 Leica LED5000 User Manual Advantages Nine high performance LEDs from different LEDS000 MCI Scene 1 50 angles and directions High contrast allows users to discover fine structures on the specimen Illumination angle of 15 40 Reproducible illumination settings Of course the Leica LED5000 MCI can also be Optimum access to specimen controlled by the LAS Leica Application Suite software Leica LED5000 MCI 62 Leica LED5000 MCI Assembly The Leica LED5000 MCI for Multi Contrast Assembly Illumination is installed using two screws For 1 Hold the Leica LED5000 MCI with one optimum accessibility the optics carrier should hand and t
2. Use the and keys to rotate the active Use the O key to switch the illuminator on segments clockwise or counterclockwise or off Use the or keys to adjust the bright ness in 10 increments Tap the or key briefly to adjust the intensity in small increments Hold one of the keys to change the intensity more quickly Leica LED3000 Leica LED5000 User Manual Leica LED5000 RL 26 Leica LED5000 RL Use Continued lf you press or for approx 2 seconds the segments rotate automatically until you press one of these keys again If you change the segment using the key the automatic changeover is kept Pressing or briefly stops the changeover Press and hold the key for approx 2 seconds to switch on the full ring of the ring illuminator H The active illuminator segments are indicated on the front control panel by 8 LEDs arranged around the on off key Leica LED3000 Leica LED5000 User Manual Leica LED5000 RL Leica LED5000 RL and Leica SmartTouch Using the Leica SmartTouch control unit H you can control both the brightness and various illumination scenarios for the Leica LED5000 RL Ring Light Leica LED3000 Leica LED5000 User Manual Adjusting the illumination e a EN bersicht Fokus zoom Tisch Licht konfig Speicher 1 Speicher 2 Speicher 3 Speicher 4 1 Touch the Light tab 2 Inthe upper area touch the symbol for
3. different intensities of vignetting may occur at low magnification Vignetting is normal and not a malfunction Leica LED3000 Leica LED5000 User Manual Use The light of the Leica LED5000 CXI can be very bright Therefore always switch on the illuminator before you look through the eyepieces Avoid looking directly into the LEDs 1 Switch on the illuminator by briefly press ing the ON OFF key The green LED on the upper left corner now lights up Leica LED5000 CXI Adjust the brightness by briefly pressing the or keys Switch off the illuminator by briefly press ing the key Leica LED5000 CXI and Leica SmartTouch Adjusting the illumination 1 Touch the Light tab 2 Inthe upper area touch the symbol of the Leica LED5000 CXI 3 Switch on the illuminator 4 Touch the lamp symbols to adjust the intensity of the light Leica LED3000 Leica LED5000 User Manual Leica LED5000 CXI Leica LED5000 CXI Dimensional Drawings Leica LED5000 CXI dimensions inmm 133 9 Leica LED3000 Leica LED5000 User Manual Leica LED5000 CXI Leica LED3000 BLI Leica LED3000 Leica LED5000 User Manual Leica LED3000 BLI 76 About the Leica LED3000 BLI The Leica LED3000 BLI for Back Light Illumina tion is suitable as a transmitted light illumina tor for use in baseplates that do not have back light functions Since the Leica LED3000 BLI is not permanently assembled
4. General Instructions Leica LED3000 Leica LED5000 User Manual General Instructions General Instructions Safety concept Before using your microscope for the first time please read the Safety concept brochure included with your instrument It contains additional information about handling and care Bezpe nostn koncepce Sikkerhedskoncept Sicherheitskonzept Ohutuseeskiri Safety concept Concepto de seguridad Concept de s curit Concetto di sicurezza Dro bas noteikumi Saugos samprata Biztons gi el r sok Veiligheidsconcept Sikkerhetskonsept Koncepcja bezpiecze stwa Conceito de seguran a Bezpe nostn pokyny Varnostni koncept Turvallisuus S kerhetskoncept LEME MICROSYSTEMS zekat SERE Leica LED3000 Leica LED5000 User Manual Use in clean rooms Leica LED illuminators can be used in clean rooms with limitations Cleaning Donotuse any unsuitable cleaning agents chemicals or techniques for cleaning Never use chemicals to clean colored surfaces or accessories with rubberized parts This could damage the surfaces and specimens could be contaminated by abraded particles In most cases we can provide special solu tions on request Some products can be modified and we can offer other accesso ries for use in clean rooms General Instructions Servicing Repairs may only be carried out by Leica Microsystems trained service technicians Only original
5. LED3000 DI 3 Switch on the illuminator 4 Touch the lamp symbols to adjust the intensity of the light Leica LED3000 Leica LED5000 User Manual Leica LED3000 DI 96 Leica LED3000 DI Dimensional Drawings Leica LED3000 DI dimensions in mm 414 Leica LED3000 Leica LED5000 User Manual Leica LED3000 DI 97 Leica LED3000 SLI Leica LED5000 SLI About the Leica LED3000 SLI Leica LED5000 SLI Use Using the Leica LED3000 SLI for Spot Light Illumination and the Leica LED5000 SLI versatile incident light settings with different contrast can be generated The double armed gooseneck with integrated LED spotlights can be put into any desired posi tion for the desired contrast everything from outstretched for very flat oblique light side light for strong shading up to high angle inci dent light with minimal shading For maximum brightness the compact LED spotlights can be positioned very close to the specimen Leica LED3000 Leica LED5000 User Manual Controls It is controlled using either the integrated keypad on the third gooseneck via Leica Appli cation Suite LAS or the Leica SmartTouch control unit LAS enables you to create fully reproducible illumination scenarios and automatically toggle between them For additional information refer to the LAS online help One of a kind operating concept The control for the illumination is located on a separate gooseneck This al
6. Leica LED5000 User Manual 2 The analyzer is installed between the tube and optics carrier To do so remove the tube from the optics carrier Place the analyzer on the optics carrier and then install the tube Fasten the components by tightening the positioning screws Leica LED5000 NVI 3 To generate the desired polarization effect rotate the rotary disk of the analyzer until the desired image quality is reached 46 Leica LED5000 NVI Installing Optional Accessories Continued Filter inserts 1 To disassemble the filter holder push the The Leica LED5000 NVI is supplied with a filter holder approx 1 cm to the side and filter holder as a standard feature Commer remove the holder downwards out of the cially available filters of size 1 2 can be used Leica LED5000 NVI The filter holder is Make sure that the filters being used are suffi assembled in the reverse order of steps ciently temperature resistant so they are not damaged by the high energy illumination g gt Additional empty filter inserts 10 725 035 can be purchased as spare parts Leica LED3000 Leica LED5000 User Manual Leica LED5000 NVI 47 Leica LED5000 NVI Use H The intensity of the illuminator can be adjusted in 10 increments The control can also be controlled via Leica Application Suite LAS or the Leica SmartTouch Leica LED3000 Leica LED5000 User Manual Use The light of the Leica LED5000 NVI A ca
7. Leica LED5000 User Manual Installation on routine focusing columns 2 1 Screw the adapter 10 450 570 to the rear side of the column Leica LED3000 DI Install the Leica LED3000 DI to the adapter on the rear side of the focusing column In doing so the height can be adapted to your requirements 92 Leica LED3000 DI Assembly Continued Installation on high performance focusing columns 1 Screwthe adapter 10 450 205 to the focus ing column 2 Install the Leica LED3000 DI on the adapter on the rear side of the focusing column In doing so the height can be adapted to your requirements Leica LED3000 Leica LED5000 User Manual Installation on older stereomicroscopes In their factory condition older stereomicro scopes do not fulfill the mechanical require ments for installing the Leica LED3000 DI on the column This gap is closed by the adapter 10 450 549 which is installed between the base stand and the focusing column 1 Screw the adapter 10 450 549 to the Leica LED3000 DI 2 Detach the baseplate from the focusing column Leica LED3000 DI 3 Install the adapter between the baseplate and focusing column 4 Fasten the baseplate using the focusing column If necessary do so using the longer screws supplied with the adapter H In this installation variant the height cannot be adapted Leica LED3000 DI Power Supply Focusing columns wit
8. can Adjusting the illumination control both the brightness and various illumination scenarios for the Leica LED3000 RL Tisch Tisch H Tisch Y Tisch Y 1 Touch the Light tab 2 Inthe upper area touch the symbol for the Leica LED3000 RL 3 Switch on the illuminator Leica LED3000 Leica LED5000 User Manual Leica LED3000 RL 4 Touch the lamp symbols to adjust the intensity of the light 5 Touch one of the symbols for the illumina tion scenarios to adjust the lighting to your needs You cannot modify the default illumina tion scenarios Leica LED3000 RL Dimensional Drawings Leica LED3000 RL dimensions in mm Leica LED3000 Leica LED5000 User Manual Leica LED3000 RL 20 Leica LED5000 RL Leica LED3000 Leica LED5000 User Manual Leica LED5000 RL About the Leica LED5000 RL Use The Leica LED5000 RL Ring Light generates a very bright and homogenous incident light It has a diameter of 80 mm and illuminates the specimen with 40 LEDs that can be switched on and off all together or in various combinations The recommended working distance is between 50 mm and 80 mm Leica LED3000 Leica LED5000 User Manual Controls It is controlled using either the integrated keyboard keypad or via Leica Application Suite LAS or the Leica SmartTouch control unit LAS enables you to create fully reproducible illumination scenarios and auto
9. illuminator on 2 seconds to switch on all 4 LED spotlights on the illuminator before you look through the or off eyepieces Avoid looking directly into the LEDs Use the or keys to adjust the bright ness in 10 increments Tap the or key briefly to adjust the intensity in small increments Hold one of the keys to change the intensity more quickly Touch the key to switch between the scenarios Touch the or key to switch within the scenario Press and hold the or key for approx 2 seconds so that the spotlights change automatically Press either of the keys again to shut off the automatic changeover Leica LED3000 Leica LED5000 User Manual Leica LED3000 MCI 58 Leica LED3000 MCI Height Adjustment of the Illuminators Height adjustment 3 For a reproducible setting move the two 1 Focus on a specimen or the black white columns to the nearest notch Write down plate this position 2 Movethe two columns until you obtain the desired contrast illuminator arc approx H If you are focusing on the black white 10 20 mm above the specimen plate position the two illuminator arcs approx 10 20 mm above the plate This will provide you with optimum illumination settings Leica LED3000 Leica LED5000 User Manual Leica LED3000 MCI 59 Leica LED3000 MCI Dimensional Drawings Leica LED3000 MCI dimensions in mm
10. on the base it can be used very flexibly when needed Due to the large level surface large products can be studied With the inductive button the Leica LED3000 BLI can be switched on and off and the brightness can be adjusted in 10 increments Leica LED3000 Leica LED5000 User Manual Leica LED3000 BLI 77 Leica LED3000 BLI Assembly and Standalone Mode Standard delivery of the Leica LED3000 BLI Required tools 1 To use the Leica LED3000 BLI on the micro Leica LED3000 BLI illumination unit None scope bases remove the 120 mm insert from the base 4Screw on rubber feet for using the Leica LED3000 BLI on flat substrates e CAN bus cable 50 cm Cleaning cloth for cleaning the Leica LED3000 BLI Leica LED3000 Leica LED5000 User Manual Leica LED3000 BLI Leica LED3000 BLI Assembly and Standalone Mode Continued Insert the Leica LED3000 BLI into the open ing of the baseplate When positioned correctly all four silicone feet rest level on the baseplate and are centered with the optics in the baseplate indentation The rubber feet that are included in the stan dard delivery are not necessary for use on a baseplate Leica LED3000 Leica LED5000 User Manual If the Leica LED3000 BLI is used without a baseplate install the 4 provided rubber feet on the corners of the bottom of the base plate and position the Leica LED3000 BLI on a flat and clean surface Leica LED3000 BLI 3
11. pack them separately Leica LED3000 Leica LED5000 User Manual Integration in third party products Refer to Safety Concept booklet Disposal Refer to Safety Concept booklet Legal regulations Refer to Safety Concept booklet EC Declaration of Conformity Refer to Safety Concept booklet Health risks Workplaces with microscopes facilitate and improve the viewing task but they also impose high demands on the eyes and holding muscles of the user Depending on the duration of unin terrupted work asthenopia and musculoskel etal problems may occur For this reason appro priate measures for reduction of the workload must be taken General Instructions Optimal arrangement of workplace work assignments and work flow changing tasks frequently Thorough training of the personnel giving consideration to ergonomic and organiza tional aspects The ergonomic design of the Leica LED3000 and LED5000 illuminators aims to limit the strain on the user to the lowest possible level About Leica LED Illuminators Leica LED3000 Leica LED5000 User Manual About Leica LED Illuminators LED Illuminant With a Future Congratulations on purchasing your LED illumi nator from Leica Microsystems You have made an excellent choice You will enjoy the high quality and well conceived operation for a long time to come and it will provide the best pos sible lighting for your work regard
12. position devi ates from the default stereo position by 2mm 70 Leica LED5000 CXI Assembly Required tools None Leica LED3000 Leica LED5000 User Manual Installing the Leica LED5000 CXI Alternative installation for manual columns 1 Connect the Leica LED5000 CXI to the 1 Connect the external power supply unit focusing column via the CTL2 connection if 10 450 266 to the Leica LED5000 CXI the focusing column is equipped with inte grated electronics 2 Unscrewthe positioning screw and remove the protective cover Leica LED5000 CXI 71 Leica LED5000 CXI Assembly Continued 3 Place the Leica LED5000 CXI on the optics carrier and tighten the positioning screw Leica LED3000 Leica LED5000 User Manual 4 Push the tube for example the inclined binocular tube into the dovetail ring and rotate it slightly in both directions until the positioning screw meshes with the guide groove Leica LED5000 CXI While holding the tube only slightly care fully tighten the positioning screw It is automatically brought to the correct posi tion Leica LED5000 CXI Use H The intensity of the illuminator can be adjusted in 10 increments H The Leica LED5000 CXI can also be controlled via the Leica Application Suite LAS or the Leica SmartTouch H Using the Leica LED5000 CXI results in an increased magnification level of 1 5x Depending on the components used
13. power supply unit 10 450 266 to the Leica LED3000 RL Leica LED3000 Leica LED5000 User Manual Installing optional accessories The optional diffuser is attached and screwed in below the ring illuminator Leica LED3000 RL The optional polarization set polarizer and analyzer is attached and screwed in below the ring illuminator You can screw the polarization set into place firmly using the small metal plate provided Leica LED3000 RL Use The light of the Leica LED3000 RL can be very bright Therefore always switch on the illuminator before you look through the eyepieces Avoid looking directly into the LEDs Leica LED3000 Leica LED5000 User Manual Using the keypad Use the key to switch the Leica LED3000 RL illuminator on or off Use the and keys to adjust the bright ness in 10 increments Touch either of the two keys to adjust the quantity of light in small increments Hold the key pressed to change the quan tity of light more quickly Leica LED3000 RL The illumination scenarios You can switch between different illumination scenarios full ring half ring quarter rings opposite quarter rings using the key The active illuminator segments are displayed on the front control panel field by means of LEDs Use the and keys to rotate the active segments clockwise or counterclockwise Leica LED3000 RL and Leica SmartTouch H Using the Leica SmartTouch you
14. the Leica LED5000 RL 3 Switch on the illuminator Leica LED5000 RL 4 Touch the lamp symbols to adjust the intensity of the light 5 Touch one of the symbols for the illumina tion scenarios to adjust the lighting to your needs You cannot modify the default illumina tion scenarios 28 Leica LED5000 RL Dimensional Drawings Leica LED5000 RL dimensions in mm Leica LED3000 Leica LED5000 User Manual Leica LED5000 RL 29 Leica LED3000 NVI Leica LED3000 Leica LED5000 User Manual Leica LED3000 NVI 30 About the Leica LED3000 NVI Leica LED3000 NVI The vertical LED light solution Unlike coaxial illumination the Leica LED3000 NVI also works for uneven specimens and specimens that have weak reflection It is ideally suited for viewing recesses and bores Minimized shadows caused by tools also contribute to an easier and more pleasing work experience with the microscope Leica LED3000 Leica LED5000 User Manual Leica LED3000 NVI 31 Leica LED3000 NVI Assembly Required tools None The Leica LED3000 NVI can be used with any objectives that have an outer diameter of 58 mm The supported working distance is between 60 mm and 150 mm Leica LED3000 Leica LED5000 User Manual Installing the Leica LED3000 NVI Alternative installation for manual columns 1 Connect the CTL2 cable provided to the 1 Connect the external power supply unit Leica LED3000
15. with 2 H silver diffusers These can be unscrewed from the LED spotlight if necessary in order to generate a more strongly focused light Leica LEDx000 SLI Use with Leica SmartTouch Using the Leica SmartTouch control unit Adjusting the illumination 3 Switch on the illuminator H you can control both the brightness and various illumination scenarios for the spot illu minator A N bersicht Fokusizoom Tisch Licht Konfig 4 Touch the lamp symbols to adjust the intensity of the light 5 Touch one of the symbols for the illumina tion scenarios to adjust the lighting to your needs Speicher 3 Speicher 4 1 Touch the Light tab Speicher 2 Speicher 1 2 Inthe upper area touch the symbol for the Leica LED SLI Leica LED3000 Leica LED5000 User Manual Leica LED3000 SLI Leica LED5000 SLI Leica LEDx000 SLI Dimensional Drawings Leica LEDx000 SLI dimensions in mm 248 Leica LED3000 Leica LED5000 User Manual Leica LED3000 SLI Leica LED5000 SLI The statement by Ernst Leitz in 1907 With the User For the User describes the fruitful collaboration with end users and driving force of innovation at Leica Microsystems We have developed five brand values to live up to this tradition Pioneering High end Quality Team Spirit Dedica
16. 000 HDI Leica LED3000 Leica LED5000 User Manual Leica LED5000 HDI 83 About the Leica LED5000 HDI The Leica LED5000 HDI for High Diffuse Illu mination is a newly designed innovative high output illuminator Its soft light reduces reflection on highly reflective specimens and prevents stray light The Leica LED5000 HDI consists of a flexible plastic dome It houses two independent LED rings that can be controlled individually It is controlled using either the integrated keypad or via the Leica Application Suite LAS or the Leica SmartTouch Leica LED3000 Leica LED5000 User Manual The Leica LED5000 HDI is installed on the objec tive using a single screw The working distance has been optimized for a height between 60 and 70 mm Constraints The Leica LED5000 HDI can only be used with objectives that have an outer diameter of 80 mm The Leica LED5000 HDI has been optimized for the planapochromat 1x and planapochromat 0 63x Leica LED5000 HDI Control via Leica Application Suite The Leica LED5000 HDI illuminator has been supported since LAS version 3 6 LAS enables you to create fully reproduc H ible illumination scenarios and automati cally toggle between them For additional infor mation refer to the LAS online help 84 Leica LED5000 HDI Assembly Connection 2 In an in focus state slide the illuminator 3 Plug the other end of the cable into one of 1 Connect the Leica CAN bus cabl
17. 45 10 Switzerland Heerbrugg 41 71 726 34 34 71 726 34 44 United Kingdom Milton Keynes 44 800298 2344 1908 246312 USA Buffalo Grove Illinois 1 8002480123 847 405 0164 10IDA26060EN Copyright by Leica Microsystems Schweiz AG CH 9435 Heerbrugg 2014 Subject to change LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH eca MICROSYSTEMS
18. Alternative instal lation for manual columns Connect the external power supply unit 10 450 266 to the Leica LED5000 NVI Leica LED3000 Leica LED5000 User Manual Leica LED5000 NVI 44 Leica LED5000 NVI Assembly on High Performance Stereomicroscopes Leica M125 Leica M165 Leica M205 Continued 8 Screw the objective to the Leica Lists of recommended objectives that can be LED5000 NVI from below used with the Leica LED5000 NVI without addi tional adapters 10 411 597 Achromatic objective f 100 mm 10 441 787 Achromatic objective f 150 mm 10 431 692 Achromatic objective f 175 mm 10 382 162 Achromatic objective f 200 mm 10 382 172 Achromatic objective f 400 mm 10 450 027 Planapochromatic objective 0 63x 10 450 028 Planapochromatic objective 1 0x 10 450 029 Planapochromatic objective 1 6x 10 450 030 Planapochromatic objective 2 0x Additional objectives can be used by means of adapters However loss of optical quality does need to be expected e g vignetting color seams reflections etc Leica LED3000 Leica LED5000 User Manual Leica LED5000 NVI Leica LED5000 NVI Installing Optional Accessories Polarization set The Leica LED5000 NVI can be equipped with an optional polarization set Using the polariza tion set reflections can be reduced on metallic surfaces for example 1 The polarizer is inserted into the filter insert on the bottom of the Leica LED5000 NVI Leica LED3000
19. LED3000 Leica LED5000 User Manual Installation on older stereomicroscopes In their factory condition older stereo microscopes do not fulfill the mechanical requirements for installing the spot illuminator on the column This gap is closed by the adapter 10 450 549 which is installed between the base stand and the focusing column 1 Screw the adapter to the spot illuminator Leica LED3000 SLI Leica LED5000 SLI 2 Detach the baseplate from the focusing column Continued on next page Leica LEDx000 SLI Assembly Continued 3 Install the adapter between the baseplate H In this installation variant the height and focusing column cannot be adapted 4 Fasten the baseplate using the focusing The spot illuminator can be used in column If necessary do so using the longer A conjunction with the objective nose screws supplied with the adapter piece Leica LED3000 Leica LED5000 User Manual Leica LED3000 SLI Leica LED5000 SLI Leica LEDx000 SLI Power Supply Focusing columns with integrated electro nics 1 Connectthe Leica CAN bus cable provided to an available CTL2 socket on the spot illu minator 2 Plug the other end of the cable into an available CTL2 socket on the focusing column Leica LED3000 Leica LED5000 User Manual Power supply via external power supply Second CTL2 socket unit H The spot illuminator has a second CTL2 1 Connect the Leica CAN bus p
20. Leica LED3000 Leica LED5000 User Manual Heica MICROSYSTEMS Contents Important Safety Notes 6 or the Leica LED3000 NVI Symbols Used 7 Leica LED3000 NVI Assembly Safety Instructions 8 Leica LED3000 NVI Use 34 Leica LED3000 NVI and Leica SmartTouch 35 About Leica LED Illuminators Leica LED3000 NVI Dimensional Drawings 36 LED Illuminant With a Future 11 Control via LAS and Leica SmartTouch 12 Power PLUS function of the Illuminators 13 NET the Leica LED5000 NVI Leica LED5000 NVI Assembly on Routine Stereomicroscopes i Leica M50 Leica M60 Leica M80 39 About the Leica LED3000 RL 15 Leica LED5000 NVI Assembly on High Performance Leica LED3000 RL Assembly 16 Stereomicroscopes Leica M125 Leica M165 Leica M205 43 Leica LED3000 RL Use 18 Leica LED5000 NVI Installing Optional Accessories 46 Leica LED3000 RL and Leica SmartTouch 19 Leica LED5000 NVI Use 48 Leica LED3000 RL Dimensional Drawings 20 Leica LED5000 NVI and Leica SmartTouch 49 Leica LED5000 NVI Dimensional Drawings 50 About the Leica LED5000 RL 22 Leica LED5000 RL Assembly 23 ni the Leica LED3000 MCI Leica LED5000 RL Installing Optional Accessories 25 Leica LED3000 MCI Assembly Leica LED5000 RL Use 26 Leica LED3000 MCI Use 58 Leica LED5000 RL and Leica SmartTouch 28 Leica LED3000 MCI Height Adjustment of the Illuminators 59 Leica LED5000 RL Dimensional Dr
21. Leica Microsystems spare parts may be used Responsibilities of person in charge of instrument Ensure that the Leica LED illuminator is operated maintained and repaired by authorized and trained personnel only Important Safety Notes Instructions for use The Leica LED3000 and Leica LED5000 illumina tors can be configured within the Leica product range in a wide variety of ways Informationen zu den einzelnen Systemkomponenten entne hmen Sie bitte der interaktiven CD ROM mit samtlichen relevanten Gebrauchsanweisungen in weiteren Sprachen Sie muss sorgfaltig aufbe wahrt werden und dem Benutzer zur Verf gung stehen Gebrauchsanweisungen und Updates stehen auch auf unserer Homepage www leica microsystems com zum Herunter laden und Ausdrucken zur Verf gung This User Manual describes the special func tions of the Leica LED3000 and Leica LED5000 illuminators and contains important instruc tions for their operational safety maintenance and accessories Leica LED3000 Leica LED5000 User Manual The Safety Concept booklet contains addi tional safety information regarding the service work requirements and the handling of the illuminators electrical and other accessories and general safety instructions You can combine individual system articles with articles from external suppliers e g cold light sources etc Please read the User Manual and the safety instructions from the supplier Before installi
22. NVI 10 450 266 to the Leica LED3000 NVI 2 Place the Leica LED3000 NVI on the objec tive from below and tighten the locking Screw 2 Connect the illuminator to the focusing column via the CTL2 connection if the focusing column is equipped with inte grated electronics Leica LED3000 NVI 32 Leica LED3000 NVI Assembly Continued Ensure that the locking screw of the A illuminator and the locking screw of the optics carrier are on a straight line as otherwise image shading may occur Leica LED3000 Leica LED5000 User Manual Leica LED3000 NVI 33 Leica LED3000 NVI Use H The intensity of the illuminator can be adjusted in 10 increments The control can also be controlled via Leica Application Suite LAS or the Leica SmartTouch The supported working distance is between 60 mm and 150 mm When pressing the keys hold the keypad between your thumb and index finger Avoid tapping the keypad with just one finger if possible Leica LED3000 Leica LED5000 User Manual Use The light of the Leica LED3000 NVI can be very bright Therefore always switch on the illuminator before you look through the eyepieces Avoid looking directly into the LEDs 1 Switch on the illuminator by briefly press ing the ON OFF key The green LED on the upper left corner now lights up Leica LED3000 NVI 2 Adjust the brightness by briefly pressing the or keys 3 Switch of
23. The power is supplied to the Leica LED3000 BLI via the power supply of a CTL bus by focusing columns or via an exter nal power supply To connect a focusing column to the Leica LED3000 BLI use the provided CAN bus cable Alternatively the Leica LED3000 BLI can be powered by an external power supply 10 450 266 79 Leica LED3000 BLI Use Switching on the focusing column 1 Switch on the focusing column using the power switch on the rear in order to supply the Leica LED3000 BLI with current Leica LED3000 Leica LED5000 User Manual Use the key to switch the illuminator on or off Use the or keys to adjust the bright ness in 10 increments Tap the or key briefly to adjust the intensity in small increments Hold one of the keys to change the intensity more quickly Leica LED3000 BLI Leica LED3000 BLI and Leica SmartTouch Adjusting the illumination Main Focusizoom Stage Li Config Brightness 8096 A N N N N NI O I LED ELI op amp 1 Touch the Light tab 2 Inthe upper area touch the symbol of the Leica LED3000 BLI 3 Switch on the illuminator 4 Touch the lamp symbols to adjust the intensity of the light Leica LED3000 Leica LED5000 User Manual Leica LED3000 BLI Leica LED3000 BLI Dimensional Drawings Leica LED3000 BLI dimensions in mm 220 Leica LED3000 Leica LED5000 User Manual Leica LED3000 BLI 82 Leica LED5
24. VI is already installed with the extension plate for assembly on the focus ing column The adapter for fastening the microscope must show the mark O on the top If the adapter has the AD mark on at the top remove the adapter and subsequently install it with the correct mark O on the top of the Leica LED5000 NVI Leica LED5000 NVI 3 Make sure that the adapter for fastening the microscope is at the correct position To assemble a Leica M50 Leica M60 the holder must be in the lower position In the higher position for a Leica M80 If neces sary detach and fasten the microscope carrier with an Allen key M4 O Leica LED5000 NVI Assembly on Routine Stereomicroscopes Leica M50 Leica M60 Leica M80 Continued 4 Fasten the Leica LED5000 NVI to the column 5 Set the optics carrier in the microscope 6 Push the tube into the dovetail ring of the using the M5 screw carrier and tighten the positioning screw optics carrier and rotate it slightly in both directions until the positioning screw meshes with the guide groove While hold ing the tube only slightly carefully tighten the positioning screw It is automatically brought to the correct position Leica LED3000 Leica LED5000 User Manual Leica LED5000 NVI 40 Leica LED5000 NVI Assembly on Routine Stereomicroscopes Leica M50 Leica M60 Leica M80 Continued 7 If the focusing
25. ar color temperature of the Leica M651 Reflections on the metallic surfaces can be effectively reduced using the optional available polarization set Leica LED3000 Leica LED5000 User Manual If the Leica LED5000 NVI with a high perfor mance stereomicroscope Leica M125 Leica M165 Leica M205 is used in combination with a 1 6x or 2 0x objective the illuminator allows for an ideal illumination of the product even with very low working distances between prod uct and objective Controls It is controlled using either the integrated keypad or via Leica Application Suite LAS or the Leica SmartTouch control unit LAS enables you to configure fully repro ducible illumination settings that are saved with the image data For additional infor mation refer to the LAS online help Leica LED5000 NVI Use The light of the Leica LED5000 NVI can be very bright Therefore always switch on the illuminator before you look through the eyepieces To reduce harmful glare the Leica LED5000 NVI was equipped with a delayed increase of brightness to the previously used level Avoid looking directly into the LEDs 38 Leica LED5000 NVI Assembly on Routine Stereomicroscopes Leica M50 Leica M60 Leica M80 Required tools Allen key M4 for assembly on the focusing column Leica LED3000 Leica LED5000 User Manual Assembly of the Leica LED5000 NVI 10 450 658 1 In the factory configuration the Leica LED5000 N
26. awings 29 Leica LED3000 MCI Dimensional Drawings 60 Leica LED3000 Leica LED5000 User Manual 2 Contents Continued About the Leica LED5000 MCI 62 the Leica LED5000 HDI Leica LED5000 MCI Assembly 63 Leica LED5000 HDI Assembly Leica LED5000 MCI Alternative Assembly 64 Leica LED5000 HDI Illumination Scenarios 86 Leica LED5000 MCI Use 65 Leica LED5000 HDI and Leica SmartTouch 88 Leica LED5000 MCI and Leica SmartTouch 67 Leica LED5000 HDI Dimensional Drawings 89 Leica LED5000 MCI Dimensional Drawings 68 About the Leica LED3000 DI About the Leica LED5000 CXI 70 Leica LED3000 DI Assembly 5 Leica LED5000 CXI Assembly 71 Leica LED3000 DI Power Supply 94 Leica LED5000 CXI Use 73 Leica LED3000 DI Use 95 Leica LED5000 CXI and Leica SmartTouch 74 Leica LED3000 DI and Leica SmartTouch 96 Leica LED5000 CXI Dimensional Drawings 75 Leica LED3000 DI Dimensional Drawings 97 About the Leica LED3000 BLI 77 e the Leica LED3000 SLI Leica LED5000 SLI Leica LED3000 BLI Assembly and Standalone Mode 78 Leica LEDx000 SLI Assembly i Leica LED3000 BLI Use 80 Leica LEDx000 SLI Power Supply 103 Leica LED3000 BLI and Leica SmartTouch 81 Leica LEDx000 SLI Use 104 Leica LED3000 BLI Dimensional Drawings 82 Leica LEDx000 SLI Use with Leica SmartTouch 105 Leica LEDx000 SLI Dimensional Drawings 106 Leica LED3000 Leica LED5000 User Manual 3
27. ca LED5000 User Manual Leica LED5000 MCI 68 Leica LED5000 CXI Leica LED3000 Leica LED5000 User Manual Leica LED5000 CXI 69 About the Leica LED5000 CXI Leica LED5000 CXI The coaxial LED light solution The new Leica LED5000 CXI is a coaxial illumina tor that combines the benefits of LED technol ogy within the smallest space long service life bright illumination in natural light quality plus integration into the Leica LAS software and fully reproducible illumination settings The Leica LED5000 CXI is ideally suited for illu minating flat reflective or polished specimens It offers substantially brighter illumination than comparable 150 watt halogen lamps Leica LED3000 Leica LED5000 User Manual Use with the microscope carrier AX If the microscope carrier AX is used in the verti cal position a quarter wave plate is necessary 1 Fastenthe quarter wave plate to the objec tive using the clamping screw 2 Rotate the quarter wave plate upwards using the knurled ring until the desired effect is attained Leica LED5000 CXI Use with the Leica M205 C Leica M205 A stereomicroscope If the Leica LED5000 CXI illuminator is used with the Leica M205 C or Leica M205 A ensure that an AX microscope carrier is used The carrier must be in position M205 during assembly In order to achieve uniform illumination in stereo viewing the AX carrier must be moved to the right as far as it will go This
28. column is equipped with integrated electronics connect the Leica LED5000 NVI to the focusing column via the CTL2 connection Alternative instal lation for manual columns Connect the external power supply unit 10 450 266 to the Leica LED5000 NVI Leica LED3000 Leica LED5000 User Manual 8 Screw the objective LED5000 NVI from below to Leica LED5000 NVI the Leica Lists of recommended objectives that can be used with the Leica LED5000 NVI without addi tional adapters 10 411 597 Achromatic objective f 100 mm 10 441 787 Achromatic objective f 150 mm 10 431 692 Achromatic objective f 175 mm 10 382 162 Achromatic objective f 200 mm 10 382 172 Achromatic objective f 400 mm 10 450 027 Planapochromatic objective 0 63x 10 450 028 Planapochromatic objective 1 0x 10 450 029 Planapochromatic objective 1 6x 10 450 030 Planapochromatic objective 2 0x Additional objectives can be used by means of adapters However loss of optical quality does need to be expected e g vignetting color seams reflections etc 41 Leica LED5000 NVI Assembly on Routine Stereomicroscopes Leica M50 Leica M60 Leica M80 Continued If you work with the standard achro matic objectives of the M series instru ments Leica M50 Leica M60 Leica M80 the illuminated surface will be smaller than the object field when in the low zoom range up to a zoom position of 1 25x This is due to the small diameter of t
29. e guide rods Make sure that the black plastic screw is installed for secur ing on the left or right guide rod see figure In this position you always have the Li same contrast with identical illumina tion This guarantees the reproducibility of an experiment H If using the AX carrier use the upper engaging position of the retaining stir rup The light of the Leica LED5000 MCI can be very bright Therefore always switch on the illuminator before you look through the eyepieces Avoid looking directly into the LEDs Leica LED3000 Leica LED5000 User Manual Installed too high Optimum height Leica LED5000 MCI Contact with the base If the optics carriers are accidentally lowered too far contact between the base and MCI may result A safety mechanism in the linkage ensures that in this case the MCI is automatically pushed upwards to prevent the possibility of damage Be sure not to place any specimens directly beneath the MCI After the optics carrier is lifted put the MCI back into the original position 65 Leica LED5000 MCI Use Continued Using the keypad The illumination scenarios Use the key to switch the illuminator on Use the and keys to toggle between the or off scenarios shown below Use the or keys to adjust the bright Maximum brightness ness in 10 increments Tap either of the two For temperature reasons it is not possible to keys to adjust the int
30. e to the illu over the objective until it can no longer the two CTL2 sockets on the rear side of minator The flat part of the plug must be touch the baseplate when folded down the focusing column facing upwards and screw it into place When doing so the control panel field should be facing the user Depending on the height of the specimen to be examined the Leica LED5000 HDI can be installed a bit higher or lower along the objective Leica LED3000 Leica LED5000 User Manual Leica LED5000 HDI 85 Leica LED5000 HDI Illumination Scenarios Using the keypad Use the O key to switch the illuminator on or off Use the key to switch between the three illumination modes Both LED rings active gt Top LED ring active gt Bottom LED ring active If both LED rings are active only the bright ness of the top ring can be changed Depending on the specimen and require ments it is thus possible to attain balanced brightness conditions for both rings Leica LED3000 Leica LED5000 User Manual Use the or keys to adjust the bright ness in 10 increments Tap either of the two keys to adjust the intensity in small incre ments Hold a key to change the intensity more quickly The illumination scenarios The flexible plastic shielding is the H central feature of the Leica LED5000 HDI It allows two illuminator operating modes Switch between the two modes by moving the plastic shieldin
31. e work flow Control the intensity of the illumination and the desired illumination scenario from your computer Stored scenarios can be called up at any time at the touch of a button so that you Leica LED3000 Leica LED5000 User Manual can be assured that you will have consistent conditions for your experiments For information on how to control the LED illuminator via LAS refer to the user manual for the LAS software Leica SmartTouch All Leica LED illuminators can also be used with the Leica SmartTouch control unit Exactly as is the case with LAS the illuminator can be switched on and off or the brightness can be adjusted Moreover you can access one of the preset illumination scenarios with a single tap All settings can be saved and retrieved later at the touch of a button The instructions for controlling the illu minator using Leica SmartTouch can be found in this User Manual About Leica LED Illuminators Leica SmartTouch Power PLUS function of the Illuminators The Leica LED3000 and Leica LED5000 illumina tors must be switched on separately after the microscopy system is switched on If the illumi nator is to switch on automatically the Power PLUS function must be activated The illumina tor is automatically switched on if the illumina tor is powered e g by means of the CAN bus of the focusing column Leica LED3000 Leica LED5000 User Manual The following illuminators are
32. ensity in small incre switch on all nine LEDs simultaneously There ments Hold a key to change the intensity fore to provide bright overall illumination the more quickly top two rows are activated The bottom row primarily provides contrast Maximum brightness Maximum contrast Point illumination Point illumination Point illumination from the rear from the left from the right Leica LED3000 Leica LED5000 User Manual Leica LED5000 MCI 66 Leica LED5000 MCI and Leica SmartTouch Using the Leica SmartTouch you can Adjusting the illumination H control both the brightness and vari ous illumination scenarios on the Leica LED5000 MCI 1 Touch the Light tab 2 Inthe upper area touch the symbol for the Leica LED5000 MCI 3 Switch on the illuminator 4 Touch the lamp symbols to adjust the intensity of the light Leica LED3000 Leica LED5000 User Manual Leica LED5000 MCI l The selected brightness is shown on the right side of the display 5 Touch one of the symbols for the illumina tion scenarios to adjust the lighting to your needs l You cannot modify the default illumina tion scenarios Leica LED5000 MCI Dimensional Drawings Leica LED5000 MCI dimensions in mm i ltd I LAI OI Lon LO LO 5 m 112 157 Leica LED3000 Lei
33. ents Leica LED3000 Leica LED5000 User Manual Danger due to hot surface A This symbol warns against touching hot surfaces e g those of light bulbs Important information This symbol indicates additional informa H tion or explanations that are intended to provide clarity General Instructions Safety Instructions Description The LeicaLED3000 and Leica LED5000 illuminators are supplements for Leica stereomicroscopes of the S series Leica 4 Leica S6 Leica S8 Apo M series Leica M50 Leica M60 Leica M80 and DMS series Leica DMS300 and Leica DMS1000 Illumi nation by power LEDs ensures ideal light conditions and is used in a wide variety of applications Intended use Refer to Safety Concept booklet Non intended use Refer to Safety Concept booklet Never use the Leica LED3000 and LED5000 illuminators and its components for IvD IvF and or medical applications since they are not intended for these Leica LED3000 Leica LED5000 User Manual The instruments and accessories described in this User Manual have been tested for safety and potential hazards The responsible Leica affiliate must be consulted whenever the instrument is altered modified or used in conjunction with non Leica components that are outside of the scope of this manual Unauthorized alterations to the instrument or noncompliant use shall void all rights to any warranty claims Place of use Refer to Safet
34. equipped with Power PLUS function Leica LED3000 RL Leica LED5000 RL Leica LED3000 SLI Leica LED5000 SLI Leica LED3000 NVI Leica LED5000 CXI Leica LED5000 NVI e Leica LED5000 HDI About Leica LED Illuminators Activating and deactivating the Power PLUS function To activate the Power PLUS function keep the plus button amp of the illuminator pressed while you connect the illuminator with the AC plug The illuminator flashes quickly three times showing that the function was activated To deactivate the Power PLUS function keep the minus button of the illuminator pressed while you connect the illuminator with the AC plug The illuminator flashes quickly two times showing that the function was deacti vated The function is deactivated in the factory condi tion Leica LED3000 RL Leica LED3000 Leica LED5000 User Manual Leica LED3000 RL 14 About the Leica LED3000 RL The Leica LED3000 RL Ring Light generates a very bright and homogenous incident light The ring illuminator illuminates the specimen with 24 LEDs that can be switched on or off together or in various combinations The Leica LED 3000 RL can be used with H any objectives that have an outer diam eter of 58 mm The supported working distance is between 60 mm and 150 mm Leica LED3000 Leica LED5000 User Manual Controls It is controlled using either the integrated keypad or via the Le
35. f the illuminator by briefly press ing the key Leica LED3000 NVI and Leica SmartTouch Adjusting the illumination I Tisch K Tisch W Tisch Y Tisch Y 1 Touch the Light tab 2 Inthe upper area touch the symbol of the Leica LED3000 NVI 3 Switch on the illuminator 4 Touch the lamp symbols to adjust the intensity of the light Leica LED3000 Leica LED5000 User Manual Leica LED3000 NVI Leica LED3000 NVI Dimensional Drawings Leica LED3000 NVI dimensions in mm Leica LED3000 Leica LED5000 User Manual Leica LED3000 NVI 36 Leica LED5000 NVI Leica LED3000 Leica LED5000 User Manual Leica LED5000 NVI 37 About the Leica LED5000 NVI Leica LED5000 NVI The vertical LED light for high performance and routine microscopes The Leica LED5000 NVI induces an illuminator that lies very close to the optical beam path of the microscope being used Because of this products with indentations can be ideally illuminated The extremely high power of the Leica LED5000 NVI makes it possible to brightly illuminate structures even in deep bores In combination with the Leica M50 Leica M60 and Leica M80 stereomicroscopes the illumi nator replaces the Leica M651 By means of the integrated filter holder commercially available filters can be used and the color temperature can be adapted both to corresponding to the application and to the practices of the user This also induces the famili
36. for the operating elements must point upwards Leica LED3000 MCI Leica LED3000 MCI Assembly Continued Connecting the illumination unit to the 2 Connect the right cable of the illumination 3 Connect the cable of the illumination unit control box unit to the lower right port of the control to the upper port of the control box 1 Connect the left cable of the illumination box unit to the lower left port of the control box Leica LED3000 Leica LED5000 User Manual Leica LED3000 MCI 56 Leica LED3000 MCI Assembly Continued Power supply ext power supply unit 1 Connect the Leica CAN bus plug of the external power supply to an available CTL2 connection on the spot illuminator Leica LED3000 Leica LED5000 User Manual H The Leica LED3000 MCI cannot be controlled using Leica Application Suite A The external power supply is not included in the standard delivery of the spot illuminator The Leica LED3000 MCI has a second CTL2 connection You can connect a second Leica LED illuminator RL NVI or CXI to this port The Leica LED3000 MCI cannot be Li connected to a column with inte grated electronics as the two components are mechanically incompatible Leica LED3000 MCI 57 Leica LED3000 MCI Use A The light of the LED3000 MCI can be Using the keypad Press and hold the key for approx very bright Therefore always switch Use the key to switch the
37. g up or down using the two tabs on the left and right of the metal ring Leica LED5000 HDI Thanks to the high flexibility it is also possible to just fold up or down one side Leica LED5000 HDI Illumination Scenarios Continued The use of flexible plastic eliminates A hard collisions with specimens to a large extent For very sensitive specimens however even the weight of the illuminator itself can cause damage A The Leica LED5000 HDI illuminator is not suitable for inspecting ESD sensitive assemblies components or parts Leica LED3000 Leica LED5000 User Manual 1 Dome folded down In this mode the Leica LED5000 HDI is particu larly powerful Homogeneity is at the highest level and the stray light from outside is blocked Leica LED5000 HDI 2 Dome folded up This mode allows continued access to the specimen for additional setup This mode also ensures illumination with minimal reflections 87 Leica LED5000 HDI and Leica SmartTouch Using the Leica SmartTouch you can H control both the brightness and vari ous illumination scenarios for the Leica LED5000 HDI Leica LED3000 Leica LED5000 User Manual Adjusting the illumination 1 Touch the Light tab 2 Inthe upper area touch the symbol for the Leica LED5000 HDI Leica LED5000 HDI Switch on the illuminator Touch the lamp symbols to adjust the intensity of the light Touch one of the symbol
38. h integrated electronics 1 Connectthe provided Leica CAN bus cable to the Leica LED3000 DI using a free CTL2 socket 2 Plug the other end of the cable into an available CTL2 socket on the focusing column Leica LED3000 Leica LED5000 User Manual Power supply via external power supply unit 1 Connect the Leica CAN bus plug of the external power supply to the Leica LED3000 DI with the CTL2 socket H The external power supply 10 450 266 is not in the standard delivery of the Leica LED3000 DI Leica LED3000 DI 94 Leica LED3000 DI Use Positioning of the illumination screen The position of the illumination screen of the Leica LED3000 DI can be individually positioned over the product due to the flexible gooseneck When not using the illuminator this can easily be swung to the side without removing it from the microscope Leica LED3000 Leica LED5000 User Manual Positioning of the keypad The flexible gooseneck allows you to move the keypad into any position desired This makes handling of the system more ergonomic while repetitive steps are also optimized by the more efficient movements Leica LED3000 DI 95 Leica LED3000 DI and Leica SmartTouch Adjusting the illumination Main Focusizoom stage Light Config Brightness 30 A I I A Memory 1 Memory 2 Il Memory 3 Memory 4 1 Touch the Light tab 2 Inthe upper area touch the symbol of the Leica
39. he objectives and is not a malfunction To prevent this effect we recom mended using the objectives listed above Leica LED3000 Leica LED5000 User Manual Leica LED5000 NVI 42 Leica LED5000 NVI Assembly on High Performance Stereomicroscopes Leica M125 Leica M165 Leica M205 Assembly of the Leica LED5000 NVI 10 450 659 1 The Leica LED5000 NVI in factory configu ration is already assembled with the exten sion plate for assembly on manual and motorized focusing columns at the factory Leica LED3000 Leica LED5000 User Manual Place the Leica LED5000 NVI on the focus 3 Press the Leica LED5000 NVI backwards to ing column so that the screw fits into the the focusing column and screw it in place thread provided and the lug fits into the using an Allen key M4 groove Leica LED5000 NVI 43 Leica LED5000 NVI Assembly on High Performance Stereomicroscopes Leica M125 Leica M165 Leica M205 Continued 4 Unscrew the three Phillips screws on the 5 Set the optics carrier on the adapter of the 6 Install the remaining microscope compo objective mount of the optics carrier and Leica LED5000 NVI and tighten it with an nents tube ergonomic accessories camera remove the spacer ring Allen key M4 etc according to the corresponding user manuals 7 If the focusing column is equipped with integrated electronics connect the Leica LED5000 NVI to the focusing column via the CTL2 connection
40. ica Application Suite LAS or the Leica SmartTouch LAS and the Leica SmartTouch enable you to create fully reproducible illumination scenarios and automatically toggle between them For additional information on controlling the illu minator via LAS please refer to the LAS online help Leica LED3000 RL Leica LED3000 RL Assembly Required tools None Installing the Leica LED3000 RL 1 Connect the Leica CAN bus cable included to the Leica LED3000 RL 2 Place the Leica LED3000 RL on the objective from below and tighten the locking screw Leica LED3000 Leica LED5000 User Manual Connection and power supply The Leica LED3000 RL can be used directly with the electronic focusing column The power is then supplied via the CTL2 connection In addition the communica tion between LAS or the Leica SmartTouch is transferred via the same connection If you work with the manual focusing H column without integrated electronics the Leica LED3000 RL must be supplied with power via the external power supply unit not included in the scope of delivery Moreover the illuminator cannot be controlled via the Leica Application Suite in this case Leica LED3000 RL Connection to the electronic focusing column Connect the Leica LED3000 RL to the focus ing column via the CTL2 port 1 Leica LED3000 RL Assembly Continued Power supply when using the manual focusing column 1 Connect the external
41. ica LED5000 User Manual Leica LED5000 NVI 51 Leica LED3000 MCI Leica LED3000 Leica LED5000 User Manual Leica LED3000 MCI 52 About the Leica LED3000 MCI Use Using the Leica LED3000 MCI for Multi Contrast Illumination reproducible in cident light settings with different contrast can be generated Both illuminator arcs with the integrated LED spotlights can be moved into the desired position depending on the configu ration microscope and objective Leica LED3000 Leica LED5000 User Manual Leica LED3000 MCI 53 Leica LED3000 MCI Assembly Scope of delivery Installation on the illumination unit The Leica LED3000 MCI consists of 2 parts 1 Slide the illumination unit laterally across Illumination unit with 2 guide rods and the microscope carrier integrated illuminator arc Control box D Required tools Allen key provided J 2 Fasten the illumination unit from above on the carrier using the two provided screws Leica LED3000 Leica LED5000 User Manual Leica LED3000 MCI Install the optics carrier 54 Leica LED3000 MCI Assembly Continued Installing the control box on routine focus columns 1 Screw the control box 10 450 570 to the adapter Leica LED3000 Leica LED5000 User Manual rA Install the adapter to the rear side of the focusing column In doing so the height can be adapted to your wishes The individ ual connection
42. ightly screw the retaining be removed during assembly stirrups on both top holes on the drive housing Constraints The Leica LED5000 MCI cannot be used together with the objective nosepiece Leica LED3000 Leica LED5000 User Manual Leica LED5000 MCI 2 Connect the Leica CAN bus cable provided to either of the two sockets The flat part of the plug must be facing downwards 3 Plug the other end of the cable into an available CTL2 socket on the column 63 Leica LED5000 MCI Alternative Assembly H Under certain circumstances the light 2 Screw the retaining stirrup into the column 3 Push the Leica LED5000 MCI onto the source must not be moved along with at the notch using the single screw If you retaining stirrup the optics carrier A typical example is multi tighten the screw the retaining stirrup is focus images in which the Z stack changes automatically moved into the correct posi while the angle of incidence of the light must tion remain the same For such purposes the Leica LED5000 MClis directly fastened to the column Installation on the column 1 Pull the retaining stirrup out of the Leica LED5000 MCI a Leica LED3000 Leica LED5000 User Manual Leica LED5000 MCI 64 Leica LED5000 MCI Use Preparation Hold the Leica LED5000 MCI with both hands and pull it downwards until it clicks into place on the bottom end of th
43. installed with the cable facing backwards However it is also possible to turn the ring illuminator sideways for example if simultane ously using the Leica LED5000 MCI system illu minator In this case the ring illuminator cannot be connected directly to the Leica LED5000 MCI Leica LED5000 RL 24 Leica LED5000 RL Installing Optional Accessories Installing optional accessories e You can screw the optional polarization set into place firmly using the metal plate provided e The optional diffuser is attached and screwed in below the ring illuminator The optional polarization set polarizer and analyzer is attached and screwed in below the ring illuminator Leica LED3000 Leica LED5000 User Manual Leica LED5000 RL 25 Leica LED5000 RL Use The light of the Leica LED5000 RL can Using the front keypad Using the side keypad be very bright Therefore always switch Use the and keys to toggle between on the illuminator before you look through the PLANAPO 1h the illuminator segments eyepieces Avoid looking directly into the LEDs Use the key to toggle between the following illuminator segments full ring half ring left right half ring front rear quarter ring opposite quarter rings eighth Switching on the focus column 1 Switch on the focus column using the power switch on the rear in order to supply ring the Leica LED5000 RL with current d 5
44. less of the type of specimen you would like to examine All of the Leica LED illuminators offer a great number of advantages you will not want to do without Constant color temperature daylight throughout the entire lifecycle Extremely long service life of up to 50 000 hours Absolutely maintenance free no lamp replacement required Leica LED3000 Leica LED5000 User Manual Depending on the illuminator individual segments can be switched on or off inde pendently from one another so that differ ent illumination scenarios are possible It is controlled either on the instrument via the Leica SmartTouch panel or via the Leica Application Suite software Extremely low power consumption at high light efficiency About Leica LED Illuminators The Leica LED illuminators work seamlessly with all Leica stereomicroscopes Using the Leica Application Suite software LAS users can control save and later call up scenarios with different microscope and light settings at the touch of a button We wish you great joy and success with your new LED illuminator by Leica Microsystems Control via LAS and Leica SmartTouch Each Leica LED illuminator can also be controlled via the Leica Application Suite LAS or the Leica SmartTouch control unit Leica Application Suite LAS Ilpla TETIN rH ji HLA The PC based LAS software allows users to inte grate each Leica LED illuminator into th
45. lows for ergonomic positioning depending on the user s prefer ences Leica LED3000 SLI Leica LED5000 SLI The difference The two spot illuminators differ only in the length of the goosenecks Leica LED3000 SLI 300 mm Leica LED5000 SLI 500 mm Thus the Leica LED3000 SLI is suitable for small compact equipment configurations in the routine stereomicroscopy area The Leica LED5000 SLI on the other hand is used with high performance stereomicroscopes for example with transmitted light stands For the sake of simplicity the designa tion Leica LEDx000 SLI will be used on the following pages when the description pertains to both models Leica LEDx000 SLI Assembly Assembly Installation on routine focusing columns 2 Install the adapter to the rear side of the The spot illuminator is installed on the 1 Screw the spot illuminator to the adapter focusing column In doing so the height focusing columns using an adapter 10 450 570 can be adapted to your requirements Required tools Allen key provided Leica LED3000 Leica LED5000 User Manual Leica LED3000 SLI Leica LED5000 SLI Leica LEDx000 SLI Assembly Continued Installation on high performance focusing columns 1 Screw the spot illuminator to the adapter 10 450 205 2 Install the adapter to the rear side of the focusing column In doing so the height can be adapted to your requirements Leica
46. lug of the socket to which an additional Leica LED external power supply to an available CTL2 illuminator RL NVI or CXI can be connected socket on the spot illuminator The external power supply is not inclu ded in the standard delivery of the spot illuminator Leica LED3000 SLI Leica LED5000 SLI Leica LEDx000 SLI Use The light of the Leica LEDx000 SLI can be very bright Therefore always switch on the illuminator before you look through the eyepieces Avoid looking directly into the LEDs Positioning the keypad The flexible gooseneck allows you to move the keypad into any position desired This makes handling of the system more ergonomic while repetitive steps are also optimized by the more efficient movements Leica LED3000 Leica LED5000 User Manual Using the keypad Use the key to switch the illuminator on or off Use the or keys to adjust the bright ness in 10 increments Tap the or key briefly to adjust the intensity in small increments Hold one of the two keys to change the intensity more quickly Touch the 6 key to reach single spot mode Leica LED3000 SLI Leica LED5000 SLI f only one spotlight is active you can enable both spotlights using the key Press and hold the key for approx 2 seconds so that the spotlights change auto matically Press the key again to disable to automatic changeover Diffusers Your spot illuminator is supplied
47. matically toggle between them For additional information refer to the LAS online help Leica LED5000 RL Leica LED5000 RL Assembly Required tools Assembly 3 Plug the other end of the cable into an None 1 Connectthe Leica CAN bus cable provided available CTL2 socket on the column to the ring illuminator The Leica LED5000 RL is installed on the H objective using a single screw It has been optimized for a working distance between 50 mm and 80 mm Constraints The Leica LED5000 RL can be used only in conjunction with the planapochromat 1x and 2 Place the Leica LED5000 RL against the Continued on next page planapochromat 0 63x objectives With all objective from below push it up as far as it other objectives the working distance is too will go and screw it into place low for adequate illumination The ring illuminator cannot be used together with the objective nosepiece Leica LED3000 Leica LED5000 User Manual Leica LED5000 RL 23 Leica LED5000 RL Assembly Continued If you work with the manual focusing Li column without integrated electronics the Leica LED5000 RL must be supplied with power via an external power supply unit not included in the delivery package Moreover the illuminator cannot be controlled via Leica Application Suite in this case Leica LED3000 Leica LED5000 User Manual For optimum accessibility of the speci men the ring illuminator should be
48. n be very bright Therefore always switch on the illuminator before you look through the eyepieces To avoid glare the Leica LED5000 NVI was equipped with a delayed raise to the previously used brightness level Avoid looking directly into the LEDs 1 Switch on the illuminator by briefly press ing the ON OFF key The white LED above the symbol now lights up Leica LED5000 NVI Adjust the brightness by briefly pressing the or keys Switch off the illuminator by briefly press ing the key Leica LED5000 NVI and Leica SmartTouch Adjusting the illumination e D Wain Focus lt oom Stage Light config Brightness 8034 E I N I E I Memory 1 Memory Memory 3 Memory 4 1 Touch the Light tab 2 Inthe upper area touch the symbol of the Leica LED5000 NVI 3 Switch on the illuminator 4 Touch the lamp symbols to adjust the intensity of the light Leica LED3000 Leica LED5000 User Manual Leica LED5000 NVI 49 Leica LED5000 NVI Dimensional Drawings Leica LED5000 NVI for Routine Stereomicroscopes dimensions in mm 9 position 7 armier positron for MBO 56 Carrier for M50 M6 amp 0 Leica LED3000 Leica LED5000 User Manual Leica LED5000 NVI 50 Leica LED5000 NVI Dimensional Drawings Continued Leica LED5000 NVI for High Performance Stereomicroscopes dimensions in mm Leica LED3000 Le
49. ng operating or using the instru ments read the user manuals listed above In particular please follow all safety instructions To maintain the unit in its original condition and to ensure safe operation the user must follow the instructions and warnings contained in these user manuals General Instructions The microscope illumination is in the exempt group risk group 0 according to EN 62471 2008 when used according to its intended use Never look directly into the LED beam A of the illumination equipment either with or without optical instruments as this increases the risk class Failure to observe this notice poses a risk of eye damage Safety note for the Leica LED5000 NVI The Leica LED5000NVI illumin tor is extremely bright In accordance with EN 62471 2008 this illuminator is assigned to risk group 2 Particularly with this illuminator make sure that you never directly look into the LED because there is a risk of eye damage Symbols Used Warning Safety hazard This symbol indicates especially impor A tant information that is mandatory to read and observe Failure to comply can cause the following Hazards to personnel Functional disturbances or damaged instruments Warning of hazardous electrical voltage This symbol indicates information that must be read and observed Failure to comply can cause the following Hazards to personnel Functional disturbances or damaged instrum
50. s for the light settings to adjust the lighting to your needs Leica LED5000 HDI Dimensional Drawings Leica LED5000 HDI dimensions in mm folded dome 109 7 gan Leica LED3000 Leica LED5000 User Manual Leica LED5000 HDI Leica LED3000 DI Leica LED3000 Leica LED5000 User Manual Leica LED3000 DI 90 About the Leica LED3000 DI The Leica LED3000 DI f r Diffuse Illumina tion is an illuminator that generates a diffuse light It consists of an illumination screen that reflects the light in different directions The diffuse features of the light source can enable a shadow free illumination of the products which is a particular advantage for documenta tion purposes Due to the flexible arm the Leica LED3000 DI can easily be installed as an additional mobile light source for example on a ring light illumi nator If needed the Leica LED3000 DI can easily be positioned between the objective and the product Its design ensures that accessibility to the product remains sufficient Leica LED3000 Leica LED5000 User Manual For higher value tasks it is recommend to use the Leica LED5000 HDI which induces an even higher diffused light with minor shadowing It is controlled using either the integrated keypad on the flexible arm via the Leica Appli cation Suite LAS or the Leica SmartTouch Leica LED3000 DI 91 Leica LED3000 DI Assembly Required tools None Leica LED3000
51. tion to Science and Continuous Improvement For us living up to these values means Living up to Life INDUSTRY DIVISION The Leica Microsystems Industry Division s focus is to support customers pursuit of the highest quality end result Leica Microsystems provide the best and most innovative imaging systems to see measure and analyze the microstructures in routine and research industrial applications materials science quality control forensic science investigation and educational applications www leica microsystems com Leica Microsystems an international company with an experienced worldwide customer service network Active worldwide Tel Fax Australia North Ryde 61 288703500 29878 1055 Austria Vienna 43 148680500 1486 80 50 30 Belgium Diegem 32 27909850 279098 68 Canada Concord Ontario 1 8002480123 847 405 0164 Denmark Ballerup 45 44540101 4454 0111 France Nanterre Cedex 33 811000 664 15605 23 23 Germany Wetzlar 49 6441294000 64 41 29 41 55 Italy Milan 39 02574861 02 574 03392 Japan Tokyo 81 354212800 3 5421 2896 Korea Seoul 82 251465 43 2514 65 48 Netherlands Rijswijk 31 70 4132 100 70 4132 109 People s Rep of China Hong Kong 852 25646699 2564 4163 Shanghai 86 2160396000 21 6387 6698 Portugal Lisbon 351 213889112 21 385 4668 Singapore 65 67797823 6773 0628 Spain Barcelona 34 934949530 93 494 95 32 Sweden Kista 46 86254545 8 625
52. y Concept booklet Electrical components must be placed at least 10 cm away from the wall and from flammable substances e Avoid large temperature fluctuations direct sunlight and vibrations These conditions can distort measurements and micro graphic images General Instructions In warm and warm damp climatic zones the individual components require special care in order to prevent the build up of fungus Responsibilities of person in charge of instrument Refer to Safety Concept booklet Ensure that The Leica LED3000 and LED5000 illumina tors and accessories are operated main tained and repaired by authorized and trained personnel only All operators have read understood and observe this User Manual and particularly the safety regulations Safety Instructions Continued Repairs service work Refer to Safety Concept booklet Only original Leica Microsystems spare parts may be used Before opening the instruments switch off the power and unplug the power cable e Avoid contact with powered electrical circuits which can lead to injury Transport Use the original packaging for shipping or transporting the individual modules of the Leica LED3000 and LED5000 illuminators and the accessory components Inorderto prevent damage from vibrations disassemble all moving parts that accord ing to the user manual can be assembled and disassembled by the customer and

Download Pdf Manuals