1. Alarm is sent every time monitoring is switched on Make sure the wires of the alarming sensor are connected properly Make sure the inputs that are not used are shorted out see Installation Manual 14 Security keypad does not react to proximity keys Use only one key at a time in front of the security keypad Make sure you are not using the installer s key The sensitive reader may stop reading keys if there has been a strong power surge voltage spike or magnetic field Use the secret code to change operating mode instead of the key Restart HouseControl from the power switch Notice that you need to reschedule the report after restart If you have a problem and wish to contact your dealer for assistance we kindly request you to fill out the following information in advance HouseControl phone number GSM subscription type and operator HouseControl version number use command VER Accessories Person who installed and tested HouseControl 15 TECHNICAL SPECIFICATIONS Dimensions 146 x 211 x 52 mm Weight ca 420 y Current consumption unit at idle 1 5 20 mA 12 V max 100 mA Supply voltage 9 145V Connectors 2 x Minidin8 Maximum values for outputs 230VAC 10A 230VAC 6A Inputs min control circuit current 3 5mA 12V max control circuit resistance 30kohm 12V Operating conditions HCE 30 70 C battery backup unit 15 40 C GSM module Sieme
2. you can enable it with command CAMERA ON This takes a picture and sends it to the phone number nnn the number must be given in international format as an MMS If you leave the number out the picture will be sent to you PICTURE nnn PICTURE ia It is recommended that you take one picture if you leave your house unoccupied for a long period of time If HouseControl sends you a burglar alarm message while you are away you can command HouseControl to take another picture and have it sent to you By comparing these two pictures you can tell if someone has rummaged through your belongings and perhaps even stolen something If you have set camera to auto mode with command CAMERA AUTO you will receive a picture automatically if monitoring is on and movement is detected The picture is sent to phone numbers stored in directory locations 1 3 There will be some delay between the activation of the motion sensor and the actual moment when the picture is taken Sending MMS message also takes some time You must tell HouseControl the multimedia settings MMS of the particular GSM subscription before it can send pictures In addition some operators may require an explicit activation of these settings If this is the case place the SIM card in an MMS capable phone and consult your operator for further instructions You will usually find the multimedia settings and activation instructions from telecommunications operators web pages Comma
3. ON OFF automatically in some cases This turns the heater connected to HouseControl on or off HEATER ON OFF nn opio nn degrees Thermostatic control Thermostatic control allows you to keep the indoor temperature at a steady level Just send the temperature value in the command HEATER 7 HEATER 7 HouseControl cannot exceed the maximum temperature limit programmed in the heating system of your house HouseControl reads its own T1 temperature sensor and turns heater on or off based on the read information Command HEATER returns the current setting Manual control You can turn heating on if you do not have your mobile phone at hand by pressing the manual heating control switch If manual control is on you cannot control heating from your mobile phone until you switch manual control off from the right hand side switch y Manual heating control on red light and off switch le 7 y Temperature alarms HouseControl monitors indoor and outdoor temperatures and alarms you if either temperature rises too high or drops too low The temperature alarm limits are adjustable When using thermostatic control you must set the temperature alarm limits at least three degrees lower and higher than what the normal temperature range is T This returns the alarm limits and the name of the sensor T T1 14 45 IN T2 30 50 OUT T3 8 45 WATER This sets alarm limits and name for the indoor temperature sensor T1
4. burglar alarm The aforementioned delays are not used when operating mode is changed by a text message A Continues on next page Operating mode after power failure You cannot change the operating mode if HouseControl is off this might occur as a result of prolonged power failure and discharged battery HouseControl returns to the same mode it was in before power failure when power is restored If monitoring goes on and you move inside the house an unnecessary burglar alarm is generated Changing operating mode by phone call You can also switch monitoring on or off by making a phone call to your HouseControl You will hear one or two beeps telling you what mode HouseControl will be in after YOU close the call One beep means monitoring will be on and two beeps mean monitoring will be off If you merely want to check the current operating mode and not change it just wait until HouseControl closes the call In this case the operating mode is not changed Behavior Unit status Monitoring is ON All alarms are enabled Switch monitoring on when you leave home W Two short blinks Monitoring is OFF Some of the alarms are disabled Te Be Switch monitoring off when you return home Ti Y T i GN One long blink Door security is on Opening a door will result in an Ex Jan 0 alarm even though monitoring is off gt a Blinks rapidly The unitis in programming mode Anyone can change OOOO the unit s settings in this mode Programming
5. HouseControl ET USER S MANUAL HOME ENERGY SAVINGS O REMOTE CAMERA 9 INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY SECURITY KEYPAD WITH PROXIMITY TAGS PREVENTION OF WATER DAMAGES WIRELESS EXTENSIONS 00000000 Read this manual carefully and keep it together with the unit PACKAGE CONTENTS Check the package contents m T Central unit Moisture sensor gt i Magnetic door switch flush mounting 2 temperature sensors Siren y ta Motion sensor v Smoke detector Battery backup unit And Materials needed in installation Tr Installation cable User s Manual and Installation Manual BATTERY BACKUP UNIT A battery backup unit is included in the package The indicator light on the front tells the charging status of the battery yellow discharged battery recharging green fully charged battery If the light is off the battery backup unit is not connected to a wall outlet ACCESSORIES Magnetic door switch flush and surface mounting dl Security keypad with proximity tags A u Remote camera I Moisture sensor 2 Siren with light Temperature sensor gt e Heat detector Carbon monoxide detector HCE Wireless extension detectors and remote controls PREPARATION 4 Purchase a GSM subscription SIM card from a telecommunications operator Prepaid s
6. N 301 511 IEC EN 60950 1 16 Notes Notes 17 18 Notes TELEMIC Isoharjantie 6 Tel 358 20 728 8740 71800 Siilinj rvi Fax 358 17 462 1212 FINLAND info telemic fi http www telemic net
7. R This text message command switches monitoring on or off or sets door security on There are two operating modes in HouseControl either monitoring is on or off Switch monitoring on when you leave home and switch if off when you return Some alarms are disabled when monitoring is off When you are at home and monitoring is off you can activate so called door security by pressing the switch at the bottom of the central unit or by sending text message ALARM DOOR Command ALARM OFF sets door security off Door security alarms if someone tries to enter or leave the house for example at night time Away At home 8 Door security ALARM ON ALARM OFF You can also switch monitoring on or off from security keypad in two different ways 1 Press Ey Key in the four digit secret code provided with the installer s proximity tag Press en If you want to change the secret code please look for more information in the Installation Manual 2 Bring one of the proximity tags near the keypad 5 10cm so that light flashes briefly Notice that you cannot change the operating mode with installer s proximity tag Delays when using security keypad When you switch monitoring on from the security keypad the signal light starts blinking You have now 45 seconds to leave your home close the door or else burglar alarm will go when coming home you have 30 seconds to switch monitoring off from the security keypad otherwise HouseControl activates
8. age EN English or Fl Finnish LANG EN LANG EN Language EN English P1 35844nnnn Your phone number is in location 1 in the phone directory Close the unit s cover and fasten it with screws Monitoring is now off and your phone number is the first number in the unit s phone directory It is important to realize that your HouseControl can be accessed only from your phone number at this point Of course you can add more users later The language command clears the entire phone directory and the name of the unit if given If you want to change language later you must re enter all users in the phone directory Version HC Eplus_Users_Manual_1_0_en_001 doc COMMANDS Use text messages to control your HouseControl HouseControl accepts commands only from those phone numbers that have been entered in the unit s phone directory You can send only one command in one text message HouseControl replies with a text message 2 Telemic HC E ALARM OFF Is monitoring on or off CAMERA OFF Is camera enabled BATT 13 0 Battery voltage IN 23 1 Indoor temperature OUT 11 2 Outdoor temperature WATER 20 3 Water temperature GSM 19 GSM signal strength 0 31 should be at least 10 for sms 15 for mms ALARMS Active alarms at the time of the question This lists all available commands HouseControl returns the command COMMANDS list also if it does not understand the received command ALARM ON OFF DOO
9. ck the situation at home by taking a picture with remote camera The most important alarms are sounded by the siren The siren will go off in 30 seconds but it can be silenced at once by pressing the left hand side switch at the bottom of your HouseControl The siren can also be silenced by bringing the proximity tag near the security keypad operating mode does not change The table below contains the alarm settings for your HouseControl The last three columns show in what modes the alarms are at all possible Alarm or notification Directory SMS MMS Call Siren ALARM ALARM Door locations ON OFF security Burglar alarm motion sensor o o o o o O Burglar alarm door o o o Fire alarm o o o Moisture alarm o e o Restart notification o o o Power failure 230V alarm o o o Low battery alarm o o o Cover open warning o o o Scheduled report o o o Indoor temperature alarm o o o Outdoor temperature alarm o o o Water temperature alarm o o o disabled by default HouseControl keeps calling until someone answers or 2 hours passes HouseControl will wait 20 seconds for your answer If you have an answering service enabled in your own GSM subscription you need to make sure the service does not answer the call in those 20 seconds 12 INSTALLATION AND TESTING Installation Manual contains detailed information about installation and testing of your HouseControl and it comes with every HouseControl product You can test smoke detector
10. d a report at specified intervals REPORT d 0 30 days PTR HouseControl can be programmed to send a report at periodic intervals To schedule a report use command REPORT d where d is the interval in days 0 never For example REPORT 14 means that report is sent every 14 days 2 weeks The report is not sent at all by default If HouseControl is restarted the report date is changed and it needs to be reprogrammed The report can be asked at any time by using the command 11 ALARMS In the case of an alarm HouseControl sends a text message to the first five phone numbers in the phone directory locations 1 5 In some alarm cases HouseControl makes a phone call and sounds the siren as well Some alarms are only sent to the phone number in directory location 1 Take this into account when deciding on the main user HouseControl sets the alarm off automatically after 24 hours or you can set the alarm off by sending command ALARM OFF or ALARM ON to your HouseControl Fire alarm a gt Alarm phone call BEEP BEEP BEEP ALARM OFF or ALARMON gt or wait 24h 24h What to do if HouseControl sends an alarm It is recommended that you make an agreement with your neighbor or with a service provider for what to do in case of an alarm If you are away on holiday your neighbor is usually nearby your house to check if everything is okay Your neighbor can call help if needed You can also che
11. isplayed in all alarm messages and in the report This saves the user s phone number nnnnn in the phone directory Px nnnnn location x 1 20 The phone number must be stored in international format To clear a phone number from location x just leave out the phone number from the command P2 358447654321 P2 358447654321 You must save users phone numbers in the phone directory before HouseControl can send alarm messages to them directory locations 1 5 Any valid user 1 20 can make setup changes All phone numbers must be stored in international format beginning with 358 in Finland If you want to change the unit s settings from a phone number not listed in the directory you must first set the unit in programming mode by opening its cover This returns the phone numbers in the directory HouseControl will send more than P one text message if not all numbers fit into one text message eee ee ee ee eee eee EEE er oros ros ee rece ee eer eee re er SMSC nnnnn This sets the phone number for the SMS center If HouseControl does not send any text messages the phone number for the SMS center might be missing from the SIM card An SMS center SMSC is responsible for handling the SMS operations of a wireless network You must program it with command SMSC nnnnn where nnnnn is the number for the SMS center You do not need this command if text messaging works without it PPPS This schedules HouseControl to sen
12. mode goes dy y Y y Y Ye on when the unit s cover is opened and off when closed Light is on no Error the SIM card is placed improperly the GSM JA blinking connection is not opened by your operator the signal is gt too weak or the PIN code reguest is not disabled If you want to use HouseControl from a phone number that does not exist in the unit s phone directory you must first set the unit in programming mode by opening its cover Monitoring must be switched off before you open the cover otherwise an alarm will be generated HouseControl will be in programming mode when it is started up the first time Anyone who knows the unit s phone number can send commands to it Activate door security from the left hand side switch of the central unit before going to bed if you want to make sure no one enters or leaves your home at night Hold down for 2 seconds Central unit s status light will start blinking in 3 M second cycles Opening a door will now generate an alarm even though monitoring is off Remember to disable the door security from the same switch before opening the door the next day If burglar alarm is activated by mistake you can silence the siren from the same switch or by using a security keypad with proximity tag in this case operating mode does not change OUTPUTS This returns status information for outputs OUTPUTS HEATER ON EXT ON This turns siren on or off The siren is sounded SIREN
13. nd Example command MMSAPN Access point name MMSAPN xxx xxx xx MMSURL URL address MMSURL http xxx xx xx MMSIP Gateway IP address MMSIP xx xx xx xx MMSPORT Port number MMSPORT xxxx MMSUSERNAME User name MMSUSERNAME MMSPASSWORD Password MMSPASSWORD You have to make these settings only once unless you change the SIM card in HouseControl If you replace the SIM card with a new SIM card from another operator you must change the multimedia settings accordingly Multimedia messages use different technique GPRS from text messages therefore sending a picture requires stronger GSM signal strength than a plain text message If HouseControl cannot send the picture because the signal is too weak it will send you text message Failed to send picture Continues on next page DEE EEE EEE eee rro EEE rro corro errr ree rere ee reer ee rere re reer ee cer rere reer rro corro coo or If you receive this symbol from HouseControl instead of an actual picture x there are problems in the connection between the central unit and the remote 1O camera Multimedia settings are correct and the GSM signal strength is sufficient but the problem is in the connection of the remote camera You cannot take a picture from a phone that is in mobile telephone exchange The command must come from a private number or you must give the number explicitly in the command Use this command to name your HouseControl nnn name max 20 NAME nnn characters The name is d
14. ned by the operator Place the SIM card in your own mobile phone and make a test call Make sure the SIM card is pushed in the SIM card slot properly Be careful when doing this Check the GSM signal strength in the area Make sure you called the right number HouseControl closes the call immediately without an answer Make sure the caller s phone number is stored in the unit s phone directory If the caller s phone number is hidden HouseControl will not know who is calling HouseControl receives commands but does not reply to them Set the unit in programming mode by opening its cover Add user s phone number in the phone directory HouseControl accepts commands only from those phone numbers that have been listed in the unit s phone directory The number for the SMS Center may be missing from the SIM card See command SMSC The unit has reached the maximum number of messages it is allowed to send in 24 hours Wait max 24h or restart the unit from the power switch Notice that you need to reschedule the report after restart HouseControl does not send text messages or make phone calls Make sure the alarm is enabled in the operating mode currently in use Make sure your number is stored in the unit s phone directory locations 1 5 HouseControl makes only a phone call when it should also send a text message Set your operator s SMS Center number with command SMSC
15. ns TC65 SIM card small 3V Antenna Quad band 850 900 1800 1900 SMA connector The unit is not protected against water or any liquids Technical specifications are subject to change without prior notice GUARANTEE Telemic Oy guarantees this HouseControl product for 12 months against material defects and flaws in manufacturing this product starting from the date of purchase verifiable by invoice Defects are repaired by using replacement parts by fixing the old components or by providing a new product for the customer The repairing does not prolong the original guarantee period Defects resulting from natural deterioration over time overloading natural phenomena or from any other inappropriate use of the product are outside the sphere of this guarantee This guarantee does not cover defects caused by accessories that are not provided or approved by Telemic Oy Neither does this guarantee cover defects that have resulted from attempts to repair or alter the unit in such way that is not approved by Telemic Oy Telemic Oy is not liable to compensate for direct or indirect losses This guarantee does not cover expenses incurred by transporting or sending the unit to the nearest licensed service PROOF OF COMPLIANCE TO STANDARDS The manufacturer guarantees that this product complies with the following standards HCE EMC EN 301 489 1 v 1 4 1 EN 301 489 7 v 1 2 1 Telemic Oy TC65 EMC EN 301 489 1 v 1 4 1 EN 301 489 7 v 1 2 1 E
16. s and carbon monoxide detectors according to the manufacturer s instructions for example using a test button The test alarm must be at least 10 seconds long for HouseControl to react to it Notice that both sirens the siren in the smoke detector and the siren connected to HouseControl must go on when there is an alarm Exception if interconnect feature is enabled in the smoke detectors every smoke detector siren should alarm You can silence the siren connected to HouseControl by flashing a proximity key near the security keyboard or by pressing the door security button in HouseControl Operating mode does not change in these cases IMPORTANT When testing HouseControl it is important that every alarm that you receive is acknowledged with message ALARM ON or ALARM OFF The manufacturer does not guarantee the delivery of SMS and MMS messages These services are provided by your telecommunications operator 13 TROUBLE SHOOTING Status light is off Switch power on and wait 30 seconds Make sure the battery backup cable is connected properly to the central unit Make sure the central unit s power switch is ON Status light is on does not blink and a phone call does not get connected to the unit Check whether the PIN code request is enabled Disable the PIN code request by placing the SIM card in your own mobile phone consult mobile phone s manuals for further help Make sure the GSM connection is ope
17. ubscriptions are discouraged because they stop working at some point when the balance runs out 2 Disable PIN code request from the SIM card Insert the SIM card in your own mobile phone and disable it from the setup menu Consult your mobile phone s manuals for further help 3 Open the screws so that the central unit s cover can be removed Make sure the power switch is OFF and then connect central unit to the battery backup a PPPS a g 5 Power switch Insert the SIM card in HouseControl 4 Power switch must be OFF while doing this You can find the SIM card slot from the bottom of the central unit You will hear a click when the card is properly locked Cecccooosococococosococococosococococosocococoooscoccococoscocococococococococosocosocososococcocecosocoococoococcccoocosococococsosooococososoococooooocooooooooosoooo Switch power ON and wait 30 seconds for the central unit to start up If the central 5 units status light does not start blinking make sure the PIN code request is disabled the GSM connection is opened by your operator the GSM signal strength is sufficient and the SIM card was placed properly in the central unit Make a test call to your HouseControl 3 You will hear 3 beeps A S A E E AAS a A i a EEE A NO ANA RT NG 6 Select language Send language command as a text message to HouseControl Select language by sending text message LANG xx to HouseControl xx being the langu
18. x y nn x low limit y high limit nn name for example WATER The water pipe temperature alarm is not enabled by default Send command TEMP3 ON to your HouseControl if you have T3 sensor connected and want to start receiving alarms from this sensor You can disable the T3 sensor with command FTEMP3 OFF The device will respond with messages starting with 118 you can ignore these Thi itch ternal device f EEN sine pea duo to aanp With EXT AUTO the external device is controlled by the operating mode It is switched on or off at the same time when monitoring status is changed This feature enables you to switch off power outlets or close water line when leaving home LEAKGUARD ON OFF This sets leakguard on or off EXT relay When leakguard is on you cannot use EXT ON or EXT OFF commands only EXT AUTO can be used When there is a moisture alarm the leakguard cuts off water automatically by using the EXT relay If there has been a leakage and the leakguard has been activated you can only reset the EXT relay by setting leakguard on or off this releases the relay If leakguard is off and there is a leakage you will only receive an alarm to your mobile phone but no water is cut off automatically CAMERA ON OFF AUTO This enables or disables the remote camera Auto setting causes picture to be taken when motion sensor is activated someone is in the house If you have a remote camera connected to your HouseControl