Contents - Colectoare Solare
Contents
1. 8 3 3 Manual heating 9 3 4 Timing heating 10 4 Installation system diagram 12 5 Protection function 00 0 0 020 000 13 5 1 Memory protection 13 5 2 Screen protection 13 5 3 Trouble protection 13 6 Quality guarantee 13 7 Technical data 14 8 Delivery SCOpe 02 2202 14 9 Device matchable to this controller 15 User s manual SR609C 08 2008 1 Safety information 1 1 Installation and commissioning e When laying cables please ensure that no damage occurs to any of the constructional fire safety measures presented in the building e The controller can not be installed in rooms where easily inflammable gas mixtures are present or may occur e The permissible environmental conditions can not be exceeded at the site of installation e Before connecting the device make su
2. Technology makes the life perfection SR609C Solar Controller For Thermal siphon Pressurized Hot Water System Operation Instruction A Please read this instruction carefully before using the controller User s manual SR609C 08 2008 Contents Contents 0 0 2 2 22 22 nnn n enn en nn nnn nen nn nen nenenee 1 1 Safety information 2 1 1 Installation and commissioning 2 1 2 About this manual 2 1 3 Liability waiver 3 1 4 Important remark 3 1 5 Description of symbols 3 2 Installation 0 20 022002 20022020222 ee n 4 2 1 Installing the controller 4 2 2 Power connection 4 2 3 Terminal connection 6 3 Function setting 8 3 1 Illustration of controller panel 8 3 2 Setting the time
3. heating gt Press button to transfer to minute area minute area blinks on the screen gt Press A Y button to set minute of the swith off time of heating gt Press button to transfer to temperature area temperature blinks on the screen gt Press A Y button to set the swith off temperature of heating gt Press SET button again to access the setting program set the switch on time of the second time section and its switch on temperature Doling like above description to set the second third time section and its corresponding switch on switch off temperature If you want to shut off one timing heating then you can set the turning on time and turning off time same value for example the second time section no this function then you can set turning on off time is 10 00 10 00 Heating signal displays on the screen it indicates timing heating is activated Note When time is outside of the preset time section back up heating doesn t work automatically even when the tank temperature reaches the switch on temperature of heating The time in this controlled is 24 hours when you set time section the switch off time of heating should be later than switch on time For User s manual SR609C 08 2008 example if you set the switch on time of heating is at 17 00 but switch off time of heating is 6 00 then this setting doesn t take effect that means within this time se
4. is necessary to take measures to avoid inductive effects so sensor cables should not be laid close to 230 volt or 400 volt cables minimum separation of 100mm If external inductive effects are existed e g from heavy current cables overhead train cables transformer substations radio and television devices amateur radio stations microwave devices etc then the cables to the sensors must be adequately shielded Sensor cables may be extended to a maximum length of ca 100 meter when cable s length is up to 50m and then 0 75mm cable should be used When cable s length is up to 100m and then 1 5mm cables should be used User s manual SR609C 08 2008 3 Function setting Connect the sensor electrical heater to the controller before After switching on power to the controller firstly it will ask for to set the you connect the power supply time and set the parameter of system 3 1 Illustration of controller panel Electrical heater in operation Display area of time Display area of temperature Indicating the preset time section Indicating the operation time of electrical heater LCD display 3 2 Setting time gt Press Clock button time displays on the screen hour selection area 00 blinks on the screen gt Press A Y button to set hour of clock gt Repress Clock minute selection area 00 blinks gt Press A Y button to set minute of clock gt After setting
5. press Clock to exit program or waiting for 12 seconds controller exits automatically the setup parameters are saved automatically User s manual SR609C 08 2008 3 3 Manual heating Description Electrical heater can be integrated into solar system as back up and it can be controlled by temperature when controller checks the tank temperature T1 is 3 C below the preset temperature electrical heater will be triggered When tank temperature T1 reaches to the preset temperature electrical heater is ceased Condition for triggering heating tank temperature is 3 C below the the preset temperature Activate deactivate this function gt Press manual button temperature area 60 C blinks on the screen gt Press A Y button to adjust the switch on temperature adjustable range 30 C 80 C factory default 60 C After 12 seconds this heating function is activated E heating signal displays on the screen gt Press manual button to switch off manual heating function Note manual heating can only heat tank one time after manual heating is triggered when temperature of tank reaches to the setting temperature manual heating ceases and manual heating function will be deactivated automatically if customer wants to heat again you need redo according to above steps User s manual SR609C 08 2008 3 4 Timing heating Function description Electrical heater can be integrated int
6. ction heating function doesn t work The correct set is like flowing it should be divided into two time sections one time section is from 17 00 to 23 59 the other time section is from 00 00 to 06 00 When user selects electrical heater as back up device we recommend using SR801 unit connecting controller and electrical heater Detailed see 4 Installation system diagram temperature sensor 5 4 u a User s manual SR609C 08 2008 5 Protection function 5 1 Memory protection In case power failure occurs controller keeps the parameter settings unchanged 5 2 Screen protection When no any press on button for 3 minutes screen protection is activated automatically and then LCD lighting lamp is switched off Through press any button to light LCD lamp again 5 3 Trouble protection When temperature sensor s T1 wiring is interrupted not connected or short circuit controller switchs off the corresponding signal output and simultaneousely E1 error code displays on the screen 6 Quality Guarantee Manufacturer provides following quality responsibilities to end users within the period of quality responsibilities manufacturer will exclude the failure caused by production and material selection A correct installation will not lead to failure When a user takes incorrect handling way incorrect installation improper or crud handling wrong connection of sensor in system and incorrect operation
7. function 2 Installation Controller can only be installed indoors and is far away from dangerous place and away from the electromagnetic field Controller should be equipped with an additional plug which should have minimum 3mm distance between the pole of the plug or effective compliance with the provisions of the installation For example switch or fuse please note wires should be separated and use the AC 2 1 Installing the controller Note the controller can only be installed in an area having an adequate level of protection gt Choosing a suitable site r f gt Drilling the up fixing hole gt Screwing on the screw gt Taking away the cover plate gt Hanging the bottom plate on the fixing hole gt Marking the position of fixing hole amp gt Taking away the bottom plate gt Drilling the hole amp gt Rehanging the bottom plate on screw gt Fixing bottom plate with amp screw 2 2 Power connection Power can only be switched on only when the housing of controller is closed an installer must make sure that the IP protection class of the controller is not damaged during installation Depending on the type of installation the cables may enter the device User s manual SR609C 08 2008 through the rear hole of the case or the lower side hole of the case Cable come from the rear remove the plastic flaps from the rear side of the case using an appropriate tool Cab
8. le come from the below Cut the left and right plastic flaps using an appropriate tool e g knife and break them out of the case Notes the flexible wire must be fastened to the case using the strain relief clamps provided User s manual SR609C 08 2008 2 3 Terminal connection Before to open the terminal please be sure to switch off the power supplier and pay attention to the local electricity supply rules e Terminal layout hod ddh m Temp Sensor Heating Power FU1 is the fuse of controller AC250V 0 5A Reset button This button is on the terminal connection panel when system program is out of working press Reset to recover the program of system to the factory settings e Power connection Power connection terminals are 10A current please sure to connect to ground e Output ports Electrical heater output H1 Electromagnetic relay max Switching current 20A for electrical heater e input ports Input port T1 for NTC10K B 3950 sensor for measuring the temperature of tank e Advice regarding the installation of temperature sensor User s manual SR609C 08 2008 Only original factory equipped NTC10K B 3950 temperature sensor are approved for use with tank it is equipped with 20m PVC cable and they are temperature resistant up to 105 C not necessary to distinguish the positive and negative polarity of the sensor connection All sensor cables carry low voltage and it
9. llation operation or wrong utilization and maintenance or that occurs in some connection with the aforementioned Moreover we do not take over liability for patent infringements or infringements occurring in connection with the use of this controller on third parties rights The manufacturer preserves the right to put changes to product technical date or installation and operation instructions without prior notice As soon as it becomes evident that safe operation is no longer possible e g visible damage Please immediately take the device out of operation Note ensure that the device cannot be accidentally placed into operation 1 4 Important remark We have carefully checked the text and pictures of this manual and provided the best of our knowledge and ideas however inevitable errors maybe exist Please note that we can not guarantee that this manual is given in the integrity of image and text they are just some examples and they apply only to our own system Incorrect incomplete and erroneous information and the resulting damage we do not take responsibility 1 5 Description of symbols A and safety risks Safety instruction The safety instructions in the manual are marked with a warning triangle It indicates measures which can lead to personal injury User s manual SR609C 08 2008 Operation steps small triangle is used to indicate operation step Notes Contains important information about operation or
10. o solar system used as back up of system and they can be triggered automatically at preset time by preset temperature Within a preset time sections when the temperature T1 of tank drops below the preset switching on temperature of this function back up heating starts to work when T1 rises up to the preset turning off temperature back up heating is stopped Within 24 hours three time sections can be set with this controller The adjustable range of switch on temperature of heating is 30 C OFF 3 C the adjustable range of switch off temperature On 3 C 80 C Setup steps gt Press SET button for 3 seconds to access the setting program set the switch on time of the first time section and its switch on temperature hour area blinks on the screen gt Press A Y button to set hour of the swith on time of heating gt Press button to transfer to minute area minute blinks on the screen gt Press A Y button to set minute of the swith on time of heating P Press mag button to transfer to temperature area temperature blinks on the screen gt Press A Y button to set the swith on temperature of heating gt Repress SET button to access the setting program set the switch off time of the first time section and its switch off temperature hour area User s manual SR609C 08 2008 blinks on the screen gt Press A Y button to set hour of the swith off time of
11. re that the energy supply matches the specifications that controller requires e All devices connected to the controller must conform to the technical specifications of the controller e All operations on an open regulator are only to be conducted cleared from the power supply All safety regulations for working on the power supply are valid Connecting and or all operations that require opening the regulator e g changing the fuse are only to be conducted by specialists 1 2 About this manual This manual describes the installation function and operation of a solar thermal controller When installing the remaining components e g the solar collectors and the storage unit are sure to observe the appropriate installation instructions provided by each manufacturer Installation electrical connection commissioning and maintenance of the device may only be performed by trained professional personnel The professional personnel must be familiar with this manual and follow the instructions contained herein User s manual SR609C 08 2008 1 3 Liability waiver The manufacturer cannot monitor the compliance with these instructions or the circumstances and methods used for installation operation utilization and maintenance of this controller Improper installation can cause damages to material and persons This is the reason why we do not take over responsibility and liability for losses damages or cost that might arise due to improper insta
12. the quality responsibility is invalid for them The warrantee expires within 24 months after the date of purchasing the controller User s manual SR609C 08 2008 7 Technical data Appearance of controller see product itself dimension 179mm x120mm x43mm Power supply AC230V 10 Power consumption lt 3W Accuracy of temperature measuring 2 C Range of tank temperature measuring 0 100 C Suitable power of electrical heater lt 2000W Inputs 1 piece NTC10K B3950 sensor lt 135 C for tank PVC cable lt 105 C Outputs 1 relay for electrical heating Ambient temperature 10 C 50 C Water proof grade IP40 Delivery scope Controller Power cable Customer manual NTC10K sensor size 6 50mm cable length20 m gt Plastic expansion screw Screw Strain relief clamp 1 piece 1 piece 1 piece 1 pieces 3 pieces 3 pieces 4 pieces User s manual SR609C 08 2008 9 Device matchable to this controller Contactor unit of high power SR801 When user selects electrical heater as back up device we recommend using SR801 unit connecting controller and electrical heater Technical data of SR801 Dimension 250mmx185mmx130mm Power supply AC230V 10 Suitable power lt 6000W Available ambient temperature 10 50 C Water proof grade IP41 Ec
Download Pdf Manuals
Related Search
Related Contents
SPCMini USER MANUAL リチウムイオンバッテリー Using Ethereal for Network Troubleshooting Capteur Microphonique HL 556 Manuel d`utilisation User`s Guide EasyView Digital Light Meter Model EA30 T-USBPL-75B Rev1.1の取扱説明書 Windows7 Manual de usuario TSX Momentum Adattatore di bus per ProfiBus DP Manuale utente Copyright © All rights reserved.