Home
DIGITAL PEDIATRIC SCALE BALANZA
Contents
1. Dispose of used batteries in accordance to your country s national state or local requirements Replace the batteries when the display reads LobAt ADAPTER POWER OPTION An optional power adapter is available ADPT 30 Plug the optional adapter NOT INCLUDED into the base of the scale and then into the outlet for power The LED next to the power jack will light up in red indicating that there is power to the scale Please refer to page 3 for information regarding the adapter available for use with this scale When an adapter is used the battery icon will not be displayed The power adapter jack is located on the back of the scale as shown below in Figure 1 TO SHUT OFF THE SCALE 1 To manually shut off the scale press the ON OFF button 2 The scale will automatically shut off after 2 minutes of inactivity if this function is enabled to help extend battery life or to reduce power usage TO DEACTIVATE REACTIVATE AUTO OFF 1 To deactivate the AUTO OFF function with the scale shut off press and hold the RELEASE button 2 Press and release the ON OFF button while still holding the RELEASE button 3 Release both buttons AOF 0 will be displayed on the screen to confirm that the Auto Off feature has been deactivated 4 To reactivate the AUTO OFF function shut the scale off and then press and hold the RELEASE button then repeat steps 2 and 3 AOF 1 will be displayed to confirm that the Auto Off feature has been reactivated NO
2. SYMBOLS AND SPECIFICATIONS FOR THIS SCALE ceee ns 3 CONNECTIVITY INFORMATION rene nnere teretes trn etn nnn 3 SET UP BATTERIES cccccccsssecscecscescecececeserecaeeeseseneeenevereceesaueeareeauserseeaueeneveeevsressneeatens 4 QUICK START INSTRUCTIONS c cecccecccecesssesceseesecerecerecrecareeeeecaeeeeuserevanevneenesneentens 5 OPERATION OF THIS SCALE ccccecccsceesceesceeseeceeesecerevrecreserecaueeaeseeeverevaressreverevsneeatens 5 NNNM YNO cer 5 CALIBRATION E 6 TROUBLESHOOTING ccceccsecccssceesceeseesseseverecerecauseaeserevrevereverevauesausearseeevarevereverevsneeatens 6 WARRANTY ccscceccessseccesscecccesceeesereeseseueesevarseaeseresarsresarseresareesesaresauseresareerecaneessenrenrevrees 7 PLEASE REGISTER YOUR SCALE FOR WARRANTY COVERAGE AT http www homscales com customers registration aspx POR FAVOR REGISTRE SU BALANZA PARA OBTENER COBERTURA DE LA GARANTIA EN http www homscales com customers registration aspx MERCI D ENREGISTRER LA BALANCE AFIN DE LA GARANTIE SUR LE http www homscales com customers registration aspx 2 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale CAUTION AND WARNING To prevent injury and damage to your scale please follow these instructions very carefully Do not transport the scale while tray is loaded For accurate weighing the scal
3. Check weight with known weight value see the calibration procedure above OVER Overload The load on the scale exceeds scale Remove weight turn scale off turn scale on again shows in display maximum capacity 44 Ibs 20 kg and try again UNDER Negative weight indicating a tare was present Clear scale of any weight and re zero scale by shows in display Load on the scale is below initial zero point pressing ZERO CLEAR button 6 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale 2 YEAR LIMITED WARRANTY 553KL What does the Warranty Cover This Health o meter Professional scale is warranted from date of purchase against defects of materials or in workmanship for a period of two 2 years If product fails to function properly return the product freight prepaid and properly packed to Pelstar LLC see To Get Warranty Service below for instructions If the manufacturer determines that a defect of material or in workmanship exists the customer s sole remedy will be repair or replacement of the scale at no charge Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value All parts including repaired and replaced parts are covered only for the original warranty period Who is Covered The ori
4. TE f set up instructions failed refer to the troubleshooting instructions If troubleshooting does not resolve the problem please contact Health o meter Professional Technical Support at 1 800 638 3722 or 1 708 377 0600 5 Figure 1 POWER ADAPTER JACK LOCATED ON THE BACK OF THE SCALE 4 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale QUICK START OPERATING INSTRUCTIONS QUICK START INSTRUCTIONS 1 Place batteries in the battery compartment or plug the scale into the wall as indicated above 2 Place the scale on a hard flat surface for accuracy and safety in use 3 Press the ON OFF button to start the scale 88 88 8 and then 0 0 0 will appear on the display along with LB and OZ or 0 00 KG To change the units for use to KG press the Kg LB button once for more information on KG see below 4 Place the baby on the scale so that its weight is evenly distributed over the tray The scale will weigh even if the baby moves 5 When a stable weight is calculated a small ring along with the word HOLD will appear on the display and the weight of the baby will lock as shown on the display NOTE If the display shows OVER the weight of the baby exceeds the capacity of this scale see Scale Specifications on page 3 6 Remove the baby from the scale The scale will continue to display the ba
5. Visit www balances com for your next Healthometer Scale Health o meter LE EN ee ee Se ne oM or ee 553KL DIGITAL PEDIATRIC SCALE BALANZA ELECTRONICA PEDIATRICA BALANCE ELECTRONIQUE PEDIATRIQUE 44 Ib x 0 5 oz 20 kg x 0 01 kg 232791 IEC 60601 1 C22 2 No 601 1 M90 UL 60601 1 USER INSTRUCTIONS INSTRUCCI NES DE USO MODE D EMPLOI Rev 2010061 1 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale Health o meter P ro fesston M l 553KL Thank you for your purchase of this Health o meter Professional scale Please read this manual carefully and keep it for easy reference or training Gracias por su compra de sta balanza Health o meter Profesional Lea estas instrucciones con cuidado y mantenga el manual disponible para futuras consultas y tambi n para su uso a la hora de orientar o formar al nuevo personal que la utilizar Merci d avoir achet cette balance Health o meter Professionnelle Veuillez lire attentivement ce manuel et le garder port e de main pour pouvoir le consulter tout moment TABLE OF CONTENTS ENGLISH NRRRRRRRRRRRRRRRRRRRRRRRRRRMRRMMMMMMMMMMMMMMKFRmhhHhEHHRRSmS IIRRRRRRRRRRRER 2 zT Ye cee 8 daV ver Y RRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRMMMMMMMMMMEFRSKEAEHRRREWWWWWWMWMMMMMMMMMMMMMM 14 CAUTION AND WARNING cerent tnnt eterne rre treten etr nnn 3
6. by s weight 7 To return the scale to 0 press the RELEASE button and the scale will be ready to weigh again RELEASE ZERO CLEAR TARE FUNCTION The tare function allows you to place other items on the scale while weighing the baby without affecting the baby s weight reading 1 Place the item you want to tare on the scale tray to weigh it 2 Press andrelease the ZERO CLEAR button to change the weight to O 3 Place the baby on the scale with the tare item and weigh normally The scale will show only the baby s weight NOTE If the scale is empty and does not read 0 press the ZERO CLEAR button once to return the display to zero WEIGHT IN KG The default weighing mode for this scale is in pounds To change the units in use to KG press the Kg LB button once To change the default setting to KG only whenever the scale is turned on please call Health o meter amp Professional Technical Support at 1 800 638 3722 or 1 708 377 0600 MAINTENANCE AND CLEANING Before first use and after periods of non use check the scale for proper operation Disconnect the scale from the power source if plugged in This scale contains electronic parts Use it carefully Do not drop kick or jump on it Do not store near chemicals heaters or radiators Do not store scale on its side To clean the scale wipe the outside of the scale and tray with a soft cloth and mild detergent Do not use abrasive cleaners Do not use isopropyl alco
7. e must be placed on a flat stable surface For accurate weighing verify proper operation according to the procedure described in this manual before each use Do not use in the presence of flammable materials Operating at other voltages and frequencies than specified could damage the equipment If the LOW BAT indicator activates for accurate weighing replace the batteries or plug the scale into a power source as soon as possible e Only manufacturer s qualified personnel should service the scale This equipment has been tested and found to comply with the EMC limits for the Medical Device Directive 93 42 EEC EN 55011 Class A and EN 60601 1 2 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation The equipment generates uses and may radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference with other devices which can be determined by turning the equipment off and on the user is encouraged to try to eliminate the interference by one or more of the following measures e HRHeorient or relocate the receiving device e Increase the separation between the equipment e Connect the scale s adapter into an outlet on a circuit dif
8. estimate of repair costs or replacement costs will be provided to you for approval prior to servicing or replacing wil Pelstar LLC 11800 South Austin Avenue B Alsip IL 60803 USA 1 800 638 3722 or 1 708 377 0600 Health o meter Professional products are manufactured designed and owned by Pelstar LLC Health o meter is a registered trademark of Sunbeam Products Inc used under license We reserve the right to improve enhance or modify Health o meter Professional product features or specifications without notice Pelstar LLC 2009 1 013485 2003 CERTIFIED 7 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales
9. ferent from that to which the other device s is connected e Consult the manufacturer at 1 800 638 3722 or 1 708 377 0600 or a field service technician for help DEFINITION OF SYMBOLS Temperature range bz AC to DC power supply 50 F to 104 F 10 C to 50 C 9V DC 200mA 9V DC 200mA Humidity range DC Connector Polarity 10 90 RH e N Attention Consult Accompanying Documents Type BF Applied Parts x AAA 10 90 RH Dea Atmospheric pressure range AGIO DE power SUBpIY Ze wan 500hPa 1060hPa SS Fe 500hPa mm 553KL SCALE SPECIFICATIONS Capacity and Resolution 44 Ib x 0 5 oz 20 kg x 0 01 kg Power Requirements 6 AA cell 1 5V batteries INCLUDED or optional Adapter Model ADPT30 120 240V AC 9V DC 50 60Hz OPTIONAL ADAPTER NOT INCLUDED Environmental Operating Temperatures 50 F to 104 F 10 C to 40 C Atmospheric Pressure 500hPa to 1060hPa Humidity 10 to 90 RH Tray Dimensions 25 x 12 34 63 5 cm x 32 4 cm 25 x 16 4 x 3 34 63 5 cm x 41 3 cm x 9 5 cm WARNING For use with Power Adaptor Model UE 15WCP 090050SPA ADPT30 only Humidity Complies with C22 2 No 601 1 M90 and UL Std No 60601 1 Type BF applied parts Internally powered Equipment is not suitable for use in the presence of flammable anesthetic mixture with air nor with oxygen or nitrous oxide 553KL SCALE CONNECTIVITY INFORMATION This scale is designed to connect to other devices via a USB p
10. ginal purchaser of the product must have proof of purchase to receive warranty service Please save your invoice or receipt Authorized dealers selling Pelstar products do not have the right to alter or modify or any way change the terms and conditions of this warranty What is Excluded Your warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instructions abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty Service make sure you keep your sales receipt or document showing proof of purchase Call 800 638 3722 to receive a return authorization RA number which must be included on the return label Attach your proof of purchase to your defective product along with your name address daytime telephone number and description of the problem Carefully package the product and send with shipping and insurance prepaid to Pelstar LLC Attention R A Repair Department 11800 South Austin Avenue B Alsip IL 60803 If your scale is not covered by warranty or has been damaged an
11. hol other solutions or sanitizing wipes to clean the display surface Do not spray it with liquid Never place the scale in the water po MIA This scale is an extremely sensitive weighing device Items such as clothing or towels placed or dropped on the scale may cause it to activate In order to prevent run down of the batteries do not store or leave anything on the scale 5 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale CALIBRATION 553KL This scale has been factory calibrated and does not require calibration prior to use For maintenance the calibration procedure may be performed using a known weight in kilograms Note Calibration weight must be no less than 11 Ib 5 kg and no more than 44 Ib 20 kg DISPLAY ACTION SHOWS Press and hold the Kg LB and ZERO CLEAR butions at the same time then momentarily CAL press the ON OFF button to start the scale When CAL appears in the display release the then Kg LB and ZERO CLEAR buttons xX XXX Press the ZERO CLEAR button C 5 will flash on the display and then the display will return C 5 then 0 to 0 Place 5 kg on the scale and when calibration number displayed stabilizes press the C 10 then 0 ZERO CLEAR button C 10 will flash on the display and then the display will return to 0 Place 10 kg on the scale and when calibration n
12. ort to allow acquisition USB of weight from the scale to help close a source of potential medical errors caused by EE incorrectly copying and then recording a weight taken This scale is EMR EHR compatible 9 am For more information regarding how to connect this scale to your computer a monitor or other device please contact Health o meter Professional Technical Support at 800 638 3722 3 http scaleman com health o meter html offers the complete line of Healthometer Medical Scales Visit www balances com for your next Healthometer Scale SET UP BATTERIES 553KL IMPORTANT To prevent falls or injury place the scale securely far from the edge of the counter table or other flat surface used to hold the scale Do not let the scale touch the wall or any other object near or around the scale while it is in use TAPE MEASURE For your convenience a measuring tape is included with the 553KL scale You may affix the tape to either the bottom or side of the weighing tray depending on your preference for visually determining the length of the baby up to 24 or 58cm Sd ia oos BATTERIES Locate the battery compartment underneath the scale base and remove the battery compartment cover 2 Place 6 new AA alkaline batteries into the battery compartment Make sure the and are positioned correctly as shown on the bottom of the battery compartment Use only 6 AA alkaline batteries 3 Replace the battery compartment cover NOTE
13. umber displayed stabilizes press the C 15 then 0 ZERO CLEAR button C 15 will flash on the display and then the display will return to 0 Place 15 kg on the scale and when calibration number displayed stabilizes press the C 20 then 0 ZERO CLEAR button C 20 will flash on the display and then the display will return to 0 Place 20 kg on the scale and when calibration number displayed stabilizes press the END ZERO CLEAR button END will appear on the display and the scale will automatically turn off TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting authorized service personnel SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on 1 Battery problem 1 Check Replace the batteries 2 Bad Power Supply or Not Plugged In 2 Check Replace Power Supply Adapter 3 Electrical Outlet not functioning 3 Use a different outlet LobAt The batteries are low Replace batteries according to instructions shows in display Questionable weight or 1 External object interfering with the scale 1 Remove interfering object from the scale be the scale does not zero 2 The display did not show 0 0 before sure the scale is not touching the wall weighing Askthe patient to step off the scale Zero the scale is not placed on a level surface scale and begin weighing process again ocale is out of calibration Place scale on level surface 4
Download Pdf Manuals
Related Search
Related Contents
Severin Piccola Semplice LG Intuition VS950 32GB 4G Black smartphone InterWrite PRS - Audience response system operating instructions Korg Karma Basic Guide - Karma-Lab rp ci s 01-es-es.indd Rentrée décalée : comment se réorienter sans perdre une année Triarch 75277-15 User's Manual Catalogue Oxygénothérapie et Aspiration Médicale Manual - Amazon Web Services Copyright © All rights reserved.
Failed to retrieve file