SVT-2 Outdoor Station B/C

image

Contents

1. o 0000 T r 0000 mn ng E a sa a DPS 000000000000 m ooo en i o o T Bus ABCD gp O E a pelee Feee ee pel i an i ht fg amp 85 260VAC U 4 Camera 3 Camera 2 Camera 1 Camera 8 ID 11 ID 10 ON ON i j see Lo O 5 OF El A A ups wee pens nuns nease espesses PSS eee Perses pesece 5 4 Multiple Indoor Monitors Connection 5 4 1 Basic IN OUT Wiring Mode Indoor Monitor Indoor Monitor RP SVT 2 DPS 5 4 2 Using DBC 4 device Wiring Mode Indoor Indoor das Monitor pa Monitor ap ae Indoor Monitor ipa Monitor Ee LI LI LJ i L L L L L L L L Li Li Li Li i Li Indoor a Monitor a Monitor iae Indoor Monitor se Monitor 6 1 DIP Switches Settings of Outdoor Station Total 2 bits on the DIP switches can be configured The switches can be modified either before or after installation i i Default setting ID 0 00 set to the first Door Station 12 AU ID 1 10 set to the second Door Station
2. LOCK 5 2 2 Door Lock Controlled with Dry Contact Note 1 The external power supply must be used according to the lock 2 The jumper must be taken off before connecting 3 Setup the Unlock Mode on the Indoor Monitor for different lock types Power on to unlock type Unlock Mode 0 by default e Power off to unlock type Unlock Mode 1 connect one lock connect two locks 123 123 Take off the Jumper Take off the Jumper BUS PL Si S2 S BUS PL Sit S S POWER POWER SUPPLY SUPPLY LOCK LOCK 5 2 3 Unlock parameter setting set on Indoor Monitor 1 Touch item on main 2 Touch the screen anywhere menu page and hold for 2s 4 A digital keypad and setting 3 Touch Installer setup item instructions will be shown Note 1 The system must be installed properly before proceding to the Unlock Parameter Setting 2 The parameter will be saved automatically so you only need to program on one monitor 3 Please note the text of the diagrams above may distinguish on each Indoor Monitor series For additional information refer to the corresponding Indoor Monitor User Manual fe 5 3 Multiple Outdoor Stations Connection Indoor Monitors
3. 10 6 3 Power SUPP siiiesssiceanecesegiiestes babes qua vista dunas na SRS aeta EI E eels dahan 12 Cable REQUIREMENTS is tenten annet beten tan 13 Camera Lens Night View LED Speaker 176 mm Name Plate Call Button Microphone Note Outdoor Station B has two call buttons 90 mm 23 mm MIC adjustment e SPK adjustment Rain Guard Lock Control Jumper Outdoor Station Code DIP Main Connection Port Lock Control Jumper To select the lock type see 5 2 1 5 2 2 Outdoor Station Code DIP Total 4 outdoor stations can be supported see 6 1 Main Connect Port To connect the bus line and the electric locks e BUS Connect to the bus line no polarity PL External lock power input connect to the power positive power 1 S2 Lock power output to connect 2 locks S Lock power output connect to the power input of locks only when using the camera to power the locks if using the external power supply for the locks the S will not be connected Lock Power supply 12Vdc 300mA Internal Power Power Consumtion 1W in standby 12W in working NO COM dry contact Max 48V dc 1 5A Unlocking time 1 to 9 seconds set by Monitor Working tempe
4. 8213 Code 13 8224 Code 24 8203 Code 3 8214 Code 14 8225 Code 25 8204 Code 4 8215 Code 15 8226 Code 26 8205 Code 5 8216 Code 16 8227 Code 27 8206 Code 6 8217 Code 17 8228 Code 28 8207 Code 7 8218 Code 18 8229 Code 29 8208 Code 8 8219 Code 19 8230 Code 30 8209 Code 9 8220 Code 20 8231 Code 31 8210 Code 10 8221 Code 21 Note Call button A configure indoor monitors with user codes 0 15 Call button B confugure indoor monitors with user codes 16 31 i Te 6 3 Power Supply SVT 2 PC6 SVT PS5 Description It supplies power for the outdoor stations indoor monitors and other accessories It supports up to 8 indoor monitors It provides power for the outdoor stations indoor monitors and other accessories It supports a maximum of 32 indoor monitors It must be used along with a SVT DPS device l2 Specifications Input Voltage 100 240Vac Input Frequency 50 60Hz Rated Output Voltage DC 28V 2V Rated Output Current 1 5A Input Voltage 100 120VAC 2 5A 200 240VAC 1 5A Input Frequency 50 60 Hz Rated Output Voltage 24Vdc Rated Output Current 4 5A Using different cables may also affect the maximum distance which the system can reach The farest monitor Indoor i Monitor t A 1 Indoor When Monitor quantity lt 20 CATS cable 1 pair of wire per 200feet 200 feet 100 feet conductor must solder the ends 60 meters 60 meters 30 meters 260 fee
5. 12 ii ID 2 01 set to the third Door Station 12 ils ID 3 11 set to the fourth Door Station 12 6 2 DIP Switches Settings of Indoor Monitor There are 3 DIP switches in total Bits 1 and 2 are reserved and must be on the default position The Bit 3 is used to configure the position of each indoor monitor in the connection line It must be set to ON if the indoor monitor is in the end of the line parallel connection or connected to a DBC 4 module It must be set to OFF if the indoor monitor is in the middle of the line daisy chain connection DIP1 amp 2 UL Reserved left to default Set to OFF When the monitor is in the middle of the line in daisy chain connection DIP3 Set to ON When the montior is at the end of the line or connected to a SVT DBC4 le Each indoor monitor should be assigned with an address in the system SVT 2 Outdoor Station B 2W12120 A maximum of 16 indoor monitors can be connected to the system Program the indoor monitors with user codes 0 15 SVT 2 Outdoor Station C 2W12130 16 indoor monitors can be connected to each call button with a maximum of 32 indoor monitors per system For additional settings refer to the Indoor Monitor User Manual 8200 Code 0 8211 Code 11 8222 Code 22 8201 Code 1 8212 Code 12 8223 Code 23 8202 Code 2
6. SVT 2 Outdoor Station B C User Manual SVT 2 Outdoor Station A SVT 2 Outdoor Station B 2W12120 2W12120 Please read this user manual prior to installing the system and keep it well for future use CONTENTS 1 PartSsand FUNnCUONS emirai a S N OENE AEAEE ENY 1 2serminal DESCKIPUONS 4 asinna a aa ee an eea al a 1 JO PSCIICALON znne eten 2 A MOUNN G eccriene rrisni Ena E incas alisa dass TE NEE 2 4 1 Mounting Without Rain Guard sessin ennnenenerennenne ee venneneren ennen 2 4 2 Mounting With Rain Guard annen eneen aa ner ennenneee vennen ennen 3 4 3 Placing Name Label soens E deaannende EE 3 4 4 Adjusting Camera Angle wie awa dementen ae aati ed 4 5 System Wiring and Connections nanne a 4 5 1 Basie Connectoren sas iai sanita ineens dada aan nanten vern quais AA do ameikanen 4 5 2 Electric Lock Conneetlofandtnosdnt eneen a 5 5 2 1 Door Lock Controlled with Internal Power nnn nennen 5 5 2 2 Door Lock Controlled with Dry Contact eener enn 5 5 2 3 How to setup the unlock parameter in Monitor nnn 6 5 3 Multi Outdoor Stations Connection nennen enen ennennenenenen 7 5 4 Multi Indoor Monitors Connettori ansaan aan 8 5 4 1 Basic IN OUT Wiring Mode nsuvarsnserennensrvensersanrdeesnade vern reen 8 5 4 2 With DBC 4 Wiring Mode nnen errei 9 lof DTO PEET 10 6 1 DIP Switches Settings of Outdoor Station naaar ennen eenen 10 6 2 DIP Switches Settings of Indoor Monitor
7. rature 10 C 45 C 4 1 Mounting Without Rain Guard 160 165cm 4 2 Mounting With Rain Guard 4 3 Placing the Name Label Move the plastic cover away to open the transparent name label cover insert a name paper then put the plastic cover back to the panel ty O Siam 4 4 Adjusting the Camera Angle 2 TS Use a screwdriver to loose the screw and then adjust the angle of the camera then fix the screw back to hold the position of the camera 5 1 Basic Connection U AC Indoor Monitor SVT 2PC6 5 2 Electric Lock Connection 5 2 1 Door Lock Controlled with Internal Power Note 1 Electric lock of Power on to unlock type should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode Parameter on the Indoor Monitor must be set to 0 by default One 1 lock connection Two 2 lock connection 123 123 EE Jumper position in 1 2 EEE E Jumper position in 1 2 BUS PL Str S2t S s s s s s s 2m LOCK AST
8. t 80 meters 130 feet 14 AWG Speaker Wire 260 feet 40 meters Stranded non shielded 80 meters When Monitor quantity gt 20 14 AWG Speaker Wire 230 feet 165 feet 100 feet Stranded non shielded 70 meters 50 meters 30 meters aCe The design and specifications of this user manual can be changed without any notification to the user All copyright and interpretation rights are reserved to SVT Innovations Inc