1. OLION 6L OL 6SZ Specifications subject to change without notice page 11 TORQUE MEASUREMENT f i SPECIFICATIONS Measuring range 2 0 560 0 ozf in 0 20 35 00 Ibf in 0 20 40 00 kgf cm 2 0 400 0 N cm 0 2 4 000 N m Accuracy 0 5 F S 1 LSD Display 4 digit LCD Operation CW CCW and fixed position Measuring modes PP Peak Mode displays PEAK torque value that will not change until a higher value is measured PD Peak Down Mode Captures first peak down value above the PDLO Real Time Displays transient torque values C Real time Output 180 data per second GO NO GO testing Programmable High and Low setpoints with both audible beep and Green Red LED indicator Statistics Number of data maximum minimum and average Data transfer ASCII 19200 bps USB miniB cable Data memory 800 data Batch Counter 1 99 CW only Power supply Ni Cad rechargeable batteries 1 2Vx4cells 600mAh Auto power save Automatic switch off after 10 minutes of non use Charging time From empty less than 5hours Working time 12 hours continuous use Bit size 6 35mm Weight 4309 Accessories page 10 AC DC Adapter Charger 100 230VAC 2 Phillips bits NIST certificate TORQUE MEASUREMENT f i ON OFF Press to turn on or off click once do not hold After 10 minutes of non use the unit shuts off MODE Select Real Time PP
2. Peak PD Peak Down C Continuous Output mode CLEAR Reset display to zero and send data to memory LCD display Displays torque value battery icon mode amp units GO NG Indicator Green for values between LO and HI setpoints flashing red for values above HI solid green for data output DOWN Change values or numeric places UP Change values or options PRG Enter programming mode or enter values MEM Display memory locations and data STAT Display statistics number of records Max Min and Ave BATTERY ICON gt A NNN CEDAR modei DID 4 E LI PP PD MEM AVE MAX MIN Ibf in MODE STATS UNITS Ratchet Operation CW CCW and fixed positions USB Port Send data to computer via USB cable Charge light lights when charging off when complete DC IN AC charger adapter receptacle RESET System reset button CHARGE LIGHT RATCHET USB PORT DC IN RESET CEDAR _Noie DID 4 gS page 3 TORQUE MEASUREMENT Cp GENERAL OPERATION 1 Press and hold MODE for one second to select from the follow ing Measuring Modes Real Time Displays torque transients no output or indicator PP Mode Peak captures peak torque peak data output PP appears on the display PD Mode First Peak capture first peak value peak data output PD appears on the display C Mode Continuous RS 232 output Display and output torque transients 180 data sec C appears on the display 2 Insert Phillips tip into
3. the screwdriver 3 To select ratchet operation turn the ratchet one click clockwise or counter clockwise from the center position To disable ratcheting turn it so the semi circle is in the center position 4 Press the CLEAR button on the display unit to zero the display Insert the screwdriver tip into the screw hold perpendicularly not at an angle and turn to measure 5 After measuring press CLEAR to zero the display for the next test PROGRAMMING Press POWER to turn on Press PRG for one second The display shows HI and then the High setpoint value This confirms the tester is ready for the following programming steps 1 High Setpoint HI After HI is displayed and the High setpoint value press DOWN to move the numeric place and press UP to select values i e 50 0 for 50 0 Ibf in then press PRG amp to enter 2 Low Setpoint LO After High value is entered LO is displayed then the Low setpoint value Press DOWN to move the numeric place and press the UP to select values then press PRG to enter page 4 TORQUE MEASUREMENT vp Output is available in PD PP and C modes In PD and PP modes peak data is output when ZERO is pressed or activated by the AUTO ZERO function In C mode the gauge outputs data continuously 160 data second Comport signal 8 data 2 stop no parity Baud Rate 19 200 bps Output Connector USB A B cable Peak Data Output Format CAN __ _ SO value _ SI uni
4. TORQUE MEASUREMENT f i 2 YEAR WARRANTY RESTRICTIONS APPLY Imada Inc warrants its products to the original purchaser to be free from defects in workmanship and material under normal use and proper maintenance for two years one year for adapters attachments batteries and cables from original purchase This warranty shall not be effective if the product has been subject to overload shock load misuse negligence accident or repairs attempted by others than Imada Inc During the warranty period we will at our option either repair or replace defective products Please call our customer service department for a return authorization number and return the defective product to us with freight prepaid The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY and we hereby disclaim all other warranties express statutory or implied applicable to the products and or software including but not limited to all implied warranties of merchantability fitness non infringement results accuracy security and freedom from computer virus In no event shall Imada Inc and or its affiliated companies be liable for any incidental consequential or punitive damages in connection with the use of its products and or software Complete color catalog available Call 800 373 9989 Imada gcom or E mail us Imada Inc 3100 Dundee Rd Suite 707 Northbrook IL 60062 USA Telephone 847 562 0834 Fax 847 562 0839 Web Site w
5. ager Jog cate through the USB port the ma ae same as a com port To verify the a OO COM port number open the car peeing Device Manager eo ake 4 DVD CD ROM drives B Floppy disk controllers db Floppy disk drives H E IDE ATA ATAPI controllers 3 Imaging devices H 8 Keyboards H 5 Mice and other pointing devices a b Modems Monitors H E Network adapters Ports COM amp LPT Communications Port COM1 Communications Port COM2 ECE Printer Bort 1p a7 USB Serial Port COM4 R Protesse SCSI and RAID controllers Sound video and game controllers H System devices H Universal Serial Bus controllers page 8 TORQUE MEASUREMENT f i Peak Down Minimum PdLO After Low value is entered PALO is displayed then the PALO value Press DOWN to move the numeric place and press the UP to select values then press PRG to enter PdLO sets a minimum torque value for Peak Down mode For example if PALO value is set at 5 0 lbf in only a reading over 5 0 lbf in will be measured in Peak Down mode Continuous Data Output Minimum CLO After Peak Down value is entered CLO is displayed then the CLO value Press DOWN to move the numeric place and press the UP to select values then press PRG to enter CLO sets the start and stop trigger points for Continuous data output Wben torque reaches the CLO value the tester starts to output data and stops if torque falls below the val
6. beeper is set to On In PP mode Under LO setpoint No LED light or beep Over LO Green LED lights Over HI Red LED flashes and beep sounds In PD mode no indicator or beep for values before Peak down is sensed Under LO setpoint Red LED flashes and slow beep sounds Between LO and HI Green LED lights and constant tone sounds Over HI Red LED flashes and fast beep sounds In Real Time and C mode Under LO setpoint no LED light or beep Between LO and HI Green LED lights and beep sounds Over HI Red LED lights and beep sounds DATA MEMORY Storing and Recalling Data from Memory Memory functions work in PP and PD modes Store up to 800 val ues in memory 1 Measure in PP or PD mode when the display resets by either Auto Zero or manually pressing CLR the peak value is stored 2 To recall a value press MEM and the last stored memory is dis played Press UP or DOWN to select a memory location i e 0 0 1 for first location and torque value The display cycles between memory location and value page 6 TORQUE MEASUREMENT f i Clearing Data from Memory Single clear Press MEM then press UP or DOWN to move to a memory location When the desired memory value is displayed press CLR CLR is displayed Press CLR again to clear the data and is displayed to confirm deletion All clear Press CLR and hold until the display shows ALL then press CLR again and is displayed to confirm deletion Downloading Mem
7. ory Data 1 Press ON OFF to turn on 2 Press MEM and after memory data is displayed press MEM again and FA is displayed Use UP or DOWN to select the first memo ry location then press MEM and LA is displayed Use UP or DOWN to select the last memory location Press MEM again and data is sent While data is output P is displayed Note By pressing DOWN switch for more than 1 sec the download function can be terminated Statistics Press STATISTICS and the number of data Max Min and Avg are dis played in sequence Auto Power Off To maximize the life of the battery power automatically shuts off after 10 minutes of non use Low Battery Indicator Sal Battery indicator status shows full half or needs recharging If the battery is empty power is turned off immediately IMPORTANT Use the provided CEDAR AC adapter charger exclusively and plug into the correct AC output It takes 5 hours to fully recharge for 12 hours of continuous use When fully charged the charge light goes off System Reset When battery power is completely depleted the tester may not work even though it has been recharged In this case press the System Reset Button page 7
8. t CR __ _ is memory location CAN ASCII control code 24 a Space code 32 SO ASCII control code 14 value Output data with sign and decimal point Plus sign represents for CW torque and minus sign for CCW Value always occupy six locations and empty locations will be filled with spaces SI ASCII control code 15 unit N m__ _ N m kgf cm kg cm Ib in _ lb in CR ASCII control code 13 Carriage Return Continuous Output Data Format CAN value CR page 9 TORQUE MEASUREMENT f i OUTPUT USB Virtual COM Port When the tester is con nected to a computer s Found New Hardware Wizard Welcome to the Found New SS Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy USB port and turned on Windows XP or Vista will recognize the tester and ask to connect to the Can Windows connect to Windows Update to search for software Yes this time only O Yes now and every time connect a device Internet Allow Windows O No not this time Update to connect to the Internet and follow the seca instructions on your screen z to download and install two drivers for the USB virtual com port For Windows 98 ME and MAC go to www ftdichip com Drivers VCP htm The PC and tester will communi Device Man
9. ue Note the display does not show any value below the CLO minimum Auto Zero Reset AC After Continuous Data Output Minimum is entered AC is dis played then the Auto Zero Reset duration value Press UP or DOWN to select 0 0C 0 1C 0 5C 1 0C 1 5C 2 0C 2 5C 3 0C and press PRG to enter 0 1C for 0 1 second and 0 0C for MANUAL RESET After measuring Auto Zero automatically resets the tester to 0 0 Batch Counter CO After the Auto Zero value is entered CO is displayed then the CO value Use the UP or DOWN keys to select a value and press PRG to enter 0 99 clockwise only Interval In After the Batch Counter value is enetered In is displayed then the In value Use the UP or DOWN keys to select a value and press PRG to enter 0 24 seconds in 2 second increments Beeper bp After Interval value is entered bp is displayed then On Press UP or DOWN to select On OFE or FE then press PRG to enter On beeper sounds for Good NG and capacity overload OFF beeper sounds for capacity overload only FF beeper sounds for NG and capacity overload page 5 TORQUE MEASUREMENT Cp 9 Units Un After the Beeper is programmed Un is displayed then the current unit selection Press UP to cycle the units Ibf in ozf in kgf cm N m and N cm After Units are entered S is displayed to confirm programming completion and zero is shown After High and Low setpoints are set and
10. ww imada com E mail imada imada com ISO 9001 amp ISO IEC 17025 Accredited 03 09 Specifications subject to change without notice CEDAR TORQUE MEASUREMENT Digital Torque Screwdriver Model DID 4 INSTRUCTION MANUAL TORQUE MEASUREMENT G3 Digital Torque Tester Screwdriver Model DID 4 List of Equipment Q Digital Torque Tester Screwdriver g with CW and CCW ratchet 4 female hex 2 Phillips tips AC adapter charger Carrying case DID 4 Digital Torque Tester Ranges Accuracy 0 5 F S 1 LSD Capacity ozf in Ibf in kgf cm N cm N m DID 4 2 0 560 0 0 20 35 00 0 20 40 00 2 0 400 0 0 2 4 000 Read First Safety Information For safety and for damage avoidance be sure to read this manual thoroughly The warranty is only valid when the product is used fol lowing the instructions provided within this manual e Do not use tester in high temperature high humidity or in damp or wet areas e Recommended operating temperature is between 0 42 C 32 100 F e Do not apply torque exceeding the rated capacity 35 Ibf in regardless of whether the unit is On or Off Avoid shock load e When charging the battery be sure to use the provided AC adapter charger exclusively e Do not use lacquer thinner or any solvent to clean the unit e Do not disassemble or modify the unit page 2 TORQUE MEASUREMENT f i DIMENSIONS DID 4 X3H JIYA v L 440 P d1d ew KOA