Home

GXV3674 v2 Series User Manual

image

Contents

1. Please temporarily disable Antivirus or Internet Security Software when download and install the Grandstream WebControl Plug in for Firefox Chrome or GSViewerX cab for Microsoft Internet Explorer Please close Browser to install the downloaded Plug in or Active X gt Please trust and install the file downloaded if prompted by the Antivirus or Security software Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 13 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video Connect the Camera to network with DHCP server Recommended The GXV3674 HD FHD VF v2 by default enabled as DHCP client it will automatically get IP address from the network with DHCP server running WINDOWS PLATFORM There are two ways for Windows user to get access to the IP Camera easily A UPnP By default the GXV3674 HD FHD VF v2 has the UPnP feature turned ON For customers using Window network with UPnP turned on most SOHO router support UPnP it is very easy to access the IP camera a Network e Find the Network icon at Windows Desktop e Click the icon to get into the Network and the IP cameras will list as Other Devices shown like below Refresh the pages if nothing displayed Otherwise the UPnP may not active in the network Other Devices 8 b D J d d D 1 IV Samsung LED40 TV Samsung LED40 3504 000b821dd012 GXV3610 FHD 000b82586afc t 1
2. Innovative IP Voice amp Video Time Lapse Photography This page allows user to configure Time Lapse Photography or period snapshot Time Lapse Photography Settings W Enable Time Lapse Photography Trigger Every Other 4 minutes T FTP Upload T SMTP Upload User Management Maintenance SMTP FIP Privacy Masks Alarm Server Time Lapse Photography EEN EER E Figure 23 Time Lapse Photography Configuration Page e Enable Time Lapse Photography Check to enable this feature User can configure the timer or duration of the triggering moment minimum value is 1 minute e FTP Upload Enabled will allow device to upload the snapshots to FTP server The FTP server is configured at FTP server page illustrate before e SMTP Upload Enabled will allow device to email the snapshots via email server The email server is configured at SMTP configuration page Click Save button to save the changes made and the feature will take effect immediately Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 46 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video Motion Detection Configuration Page Set Alarm This page allows user to configure motion detection to trigger alarms Motion Detection Settings Motion detection will be disabled if both primary and secondary codec are set to MJPEG lw Show Regions LASE fue ETE MED Maintenance eee ME
3. Last Updated 02 2015 stream Innovative IP Voice amp Video System A ccess e Disable Telnet Check to disable Telnet to enhance security e Enable UPnP Discovery Used for UPnP automatic discovery of the device in related network environment Default enabled NOTE Only XML based automatic provisioning is supported by GXV3674 HD FHD VF v2 Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 39 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 andstream Innovative IP Voice amp Video This page intentionally left blank Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 40 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 CC inn Innovative IP Voice amp Video SMTP Setting Page Email Alarm This page allows user to configure email client to send out email when alarm trigged SMTP Server Settings Enable SMTP E SMTP Server smtp gmail com SMTP Server Port User Management SMTP Server Port 465 Maintenance From E Mail address my_id gmail com SMTP To E Mail address 1 other email com FIP l To E Mail address 2 6179116110 verizon net Privacy Masks Alarm Server To E Mail address 3 work abc_corp com Time Lapse Photography ikar Meu my id Motion Detection Password assent syslog SOL lw Email Subject Front Door Motion Detected There is something happening at front door Please check out immediately ES htip IPCam myDDNS org 10020 OR http IPCam myDDNS
4. SMTP Sensitivity FIP Privacy Masks Alarm Server Time Lapse Photography Motion Detection syslog ale see TEST TT TEM Auto M Minimum duration required by motion detection trigger s a vi Minimum interval of different motion detection event s Figure 24 1 Motion Detection Configuration Page Show Regions When checked Motion Detection region with number will be displayed as a white rectangle in the screen When Edit clicked the Rectangle will become Red as shown in Figure 16 1 e Enable Motion Detection When checked Motion Detection is enabled There are total 16 regions be available for MD configuration from region Oto 15 Select and highlight the number of region to configure the MD and the sensitivity e Minimum duration required by motion detection trigger s Min period in second to identify as a valid MD event Default is Auto max value is 5 second The setting helps to reduce false alarm based on user s scenarios e Minimum interval of different motion detection event s Min time frame in second to identify as different MD events if there are constant motions Max value is 60 seconds or minute This setting helps accuracy of MD triggered recording Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 47 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 dstream Innovative IP Voice amp Video Alarm Action Record Video From Pre Alarm Upto 10 M seconds to After Alarm
5. 3 5 Last Updated 02 2015 ndstream Innovative IP Voice 4 Video GXV3674 HD FHD VF v2 HOME WEB PAGE The Home Page of GXV3674 HD FHD VF v2 LWEN I d EH Figure 7 Home Page of GXV3674 HD FHD VF v2 D oU ee de 11 12 13 14 15 16 Real Size Window Size icon ZOOM BRIGHTNESS bar CONTRAST bar SATURATION bar Language icon Configuration icon Default Video Parameter icon Stop Play Video icon Capture Snapshot icon Record icon Listen On Off icon Talk On Off icon Playback Local Configuration Motion Detection Alarm Indicator Grandstream Networks Inc Click to switch between real resolution size and embedded window size video Zoom in or Zoom out during ePTZ operation Default Not Applicable Adjust the image or video brightness Adjust the image or video contrast Adjust the image or video saturation Click to switch webpage language Current support Chinese English and Russian Click to enter Configuration Page to configure the parameters of GXV3674 HD FHD VF Administration privilege required Click to reset video parameters Brightness Contrast Saturation to default Click to Stop and Play the embedded live video Click to capture and save a snapshot of current displayed video frame Default directory C Capture using date stamp as folder name Click to Start Stop record of current video stream into a file Default directory C Record Toggle to list
6. DO 0E 82 27 FB CD 2 IPCAMERA GaY3651FHD 1 0 1 3 M 3581FHD 132 168 22 115 DU 554 00 08 82 42 40 35 3 IPLAMERA Day 3BBeF HD 1 0 1 30 Gavabbz FHD 132 168 22 144 au 554 00 06 82 27 F1 13 4 IPCAMERA Dau 3500 1 0 1 30 35V 35D 132 168 22 184 DU ood DO 0B 82 37 25 4 5 IPLAMERA Gaw 3662H 1 0 1 40 Ge 3BB2HD 192 168 22 71 DU 254 UL 0B 82 31 3 amp D 8 b DECODER Gaw 3500 1 0 1 30 192 168 22 70 DU Sek DO 06 82 37 26 35 7 IPCAMERA Gawab10 HD 1 0 3 0 132 168 2278 B nod DO 0B 82 60 BC FE a 0 3 168 22 TB Sz Bx BC 3 IPCAMERA Ges 4610 FHD 1 0 3 5 132 168 22 106 DU ood O0 06 82 60 6D 39 10 IPLAMERA Day 361 SPI 1 0 35 GavablSwPI HD 192 168 22 54 DU 254 UL 0E 82 5D SL 3E 11 IPCAMERA Day 3E11IR HD 1 0 3 5 GawsblllK HD EP 132 158 22 1U7 DU Sek 00 06 82 27 FF 95 EE IP Address Configuration wihi Configuration L Old IP Use DHCP New IP fo Bing Sub net mask e Modify IP Figure 3 GS_Search Result Page of GXV3674_HD FHD_VF v2 5 Double click the column of the detected camera the browser will automatically open and link to the device IP and the web configuration page 6 The browser will ask for plug in or ActiveX if not installed otherwise it will get to Home page and start to show the video captured by the camera by default the camera enabled anonymous access Click Configuration icon the browser will ask credentials to authorize configuration Enter the administrator user name a
7. DP MEM en D w Don E e GEE Ee 33 STATUS PAGE l aret dete on Bibi sete tate kes ke e ak a EE EE IE DI pM E e A a e e ko ok kiba ty 36 ADVANCED SETTINGS EXPLANATION eene se see sek see nnn nnnm Ek Rae Ek Rae kk ee EER ae ER Rae ER Rae ERK Re ER ae 37 USER MANAGEMENT PAGE osse Gito et kes st oo UP e ene ka a ie AN e at pk DIU A Ed ne 37 MAINTENANCE se ket pyej at tt et ea a EE N 38 SMTP SETTING PAGE EMAIL MARK sesse p SU ef ka pan e a GER Oe eki pot ONE ep a e Gee ee en a UR EIU RU ken 41 FIT SErINGS PAGE UPLOAD ALARM soseer se en soutit oe ede da vore ge e kk l a a e ta kk kd lk d 43 PT EE 44 ALARM SERVER SETTINGS PAGE UPLOAD ALARM TO SUPPORTED VMS OR HTTP SERVER 45 TME LAPSE PHOTOGRAPHY d oes does cutus cou ee Erie MU LU Ole DUE D DD eM E M aje 46 MOTION DETECTION CONFIGURATION PAGE SET ALARM ese ese ees esse ee ee ee nennen enne nennen nnne nnn nnns nnn nnns 47 REMOTE ALARM OUT PEERING WITH GXV3500 D COpDER n ee ee ees ee ee nena rennes 50 SYSLOG SETTINGS PAGE TROUBLESHOOTING Hen 53 SOFTWARE UPGRADE s o ie Gie ee ee ee Ee jn Ee dil kb ko at ee Ee ee ay DE kk a Ee ee ke ee EE 54 INSTRUCTIONS FOR LOCAL FIRMWARE UPGRADE USING TFTP SERVER ees see ee ee ee ee ees ee ee ee ee ee ee ee ee ee ee ee 55 CONFIGURATION FILE DOWNLOAD 55 RESTORE FACTORY DEFAULT SETTING oos ees vee see ees se ee ek see ske ees sk ke e nnnm ER Rae Ek Rae RR Rae Rae ER ae E 56 RESET FROM WEB INTEREACE ees
8. FHD VF v2 is very versatile infrared IP Camera it can be used in a lot of scenarios LAN w o Internet For multi room or a bigger space multiple GXV3674 HD FHD VF v2 might be required User can establish a local area network using PoE switch If remote access required a router with internet access may add in Equipment List 1 Several GXV3674 HD FHD VF v2 2 Ethernet cables 3 Switch Static IP required to configure to IP Cameras 4 PoE Switch Optional better solution If remote access to the cameras required to view the LIVE video stream then broadband Internet is required and more equipment required 5 Router Gf DHCP configured than static IP is not required although still recommended 6 Broadband Internet Access FiOS Cable or DSL 7 iPhone or Android phone Application like IP Cam Viewer Figure 5 1 GXV3674 HD FHD VF v2 Working in LAN Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 19 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 Innovative IP Voice amp Video LAN with Internet For multi room or a bigger space with Internet access and local video recording required following list 1s recommended Equipment List 1 2 3 4 5 6 7 8 Several GXV3674 HD FHD VF v2 GVR3550 NVR Ethernet cables Switch PoE Switch recommended Router Broadband Internet Access FiOS Cable or DSL iPhone or Android phone Application like IP Cam Viewer GSurf Pro Remot
9. Out Callee or call receiver s number when alarm call trigged e White List Allowed Caller Phone numbers allowed calling into the camera NOTE gt GXV3674_HD FHD_VF v2 requires external microphone and amplified speakers connected to support audio calls Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 35 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 ndstream Innovative IP Voice 4 Video Status Page This page shows the GX V3674_HD FHD_VF v2 operation status Administration fiterface System Statistics Product Model GAV3674 FHD VF Hardware Version V1 0A mam Part Number 9670005410A Video amp Audio Bootloader Version 1 0 3 6 OSD Core Version 1 0 3 6 CMOS Settings Base Version 1 0 3 6 Firmware Version 1 0 3 6 system Up Time Since 5 days 12 hours 16 minutes DDNS SIP Network Status Status MAC Address 00 0B 82 58 22 2C LAN IP Address 50 241 102 228 LAN Subnet Mask 255 255 255 240 LAN Default Gateway 50 241 102 238 DDNS Status Disabled SIP Registered Offline IR CUT Status IR CUT Status Night Figure 16 Status Page NOTE IR CUT Status showed Daytime or Night When SIP account registered the status will display Online in Green When SIP account unregistered the status will display Offline in Red as below SIP Registered Offline Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 36 of 59 Firmware Version 1 0 3 5 Last U
10. Upgrade and Provisioning Privacy Masks Upgrade via HTTP Alarm Server Time Lapse Photography Firmware Server Path firmware grandstream com Motion Detection Config Server Path config grandstream com Syslog XML Config File Password TELTIS Automatic Upgrade Interval Minutes 10080 DHCP Option 66 Override Server m 3CX Auto Provision D Automatic Upgrade Iv Save Figure 26 Firmware Upgrade and Provisioning NOTE Grandstream recommends end user use the Grandstream HTTP server firmware grandstream com For large companies we recommend to maintain their own TFTP HTTP HTTPS server for upgrade and provisioning procedures Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 54 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video Instructions for local firmware upgrade using TFTP server 1 Unzip the file and put all of them under the root directory of the TFTP server 2 Load the TFTP server from the PC and make sure the device in the same LAN segment 3 Please go to File gt Configure gt Security to change the TFTP server s default setting from Receive Only to Transmit Only for the firmware upgrade 4 Sitartthe TFTP server 5 In webGUI of IP camera configure the Firmware Server Path with the IP address of the PC 6 Update the change and reboot the unit End users can also choose to download the free HTTP server from hitp nt
11. accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help RF EXPOSURE INFORMATION SAR This device is designed and manufactured not to be exceeded the emission limits for exposure to radio frequency RF energy set by the Federal Communications Commission of the United States The exposure standard for wireless devices employing a unit of measurem
12. also uploaded to FTP server if configured The pre post alarm snapshot numbers can be configured based on time in second to meet user s requirement Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 48 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video Time Schedule Config Click the Time Schedule Config will bring up following interface to allow user to configure the Time Schedule for the Motion Detection to take action Motion Detection Time Schedule D 1 2 3 4 5 6 7 g 9 410 d 12 13 14 15 0 2 4 6 8 0 1 4 W 418 20 22 72 SR D ai ti tt AE WE WE NEE EEN NEE EN NEE EEN EE EN NE EEN NEE EN EE EN IO EE EN IO EE EN EE WE ee EE EE WE EE EE L ni 1 1 1 1 1 D ti BL D BD Ia D BP BD aA BE BD E Wa EEN EEN NEK EEN HE n de de B or dd Bog B og B ou Bor B or B on Bor Don Bon B n B on Bon B on B on Bon B on ti B on EH oon por por jos gor HEN NE NE EE jou joo poo jos joo jos poo jos jos jos joo joo jos joo joo EE EE EE 5 gp 5 pF UH gp n B ND ID d B d Bou B EN IN B B d B N o8 B AD n B EN d gp N ND dg B N B d ML EEN NEL A IO NEL A A EEN HEL EEN EEN EEN EE EEN NEL EEN NEL EEN HEL EEN HEL EEN NEL EEN HEL EEN HEN EN HEL EEN HEN EEN HEL EEN HEL EEN ee HEL EEN m so i i i i i Ii I L MER L L L RE ERE EE EE HEEN ee L MER L ee REI l 1 P 1 f E E f dez Ff E ER BE E ft c gd E EEUE EEUE P
13. be beneficial to disable the WDR function if there is no high contrasting light in order to maximize the camera s low light performance Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 30 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video Networking Setting Page This page allows user to configure network related parameters IP Address Configuration Dynamically Assigned via DHCP Statically Configured as IP Address 192 168 1 68 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 DNS Configuration Obtain DNS Server Address Automatically Use the Following DNS Server Address Primary ONS Server 64 119 143 2 Secondary DNS Server 71 243 0 12 HTTP HTTP Port 8088 Save Figure 13 Networking Setting Page e IP Address Configuration Camera IP address configuration O Dynamically Associated via DHCP Default setting DHCP server assign IP to camera O Statically Configured as Static IP address configuration e DNS Configuration DNS server IP Must be configured if using static IP e HTTP Web access TCP port default 80 NOTE gt If camera behind SOHO router with port forwarding configuration for remote access static IP or static DHCP has to be used to avoid IP address change after router reboot gt TCP port above 5000 suggested if Port Forward HTTP for remote access due to some ISP would block port 80 for inbound traffic For example cha
14. ee Se Ge Ge Ge Pep Sous ajan EE aba 25 FIGURE 10 1 VIDEO amp AUDIO SETTINGS PAGE ees sees ees see e Re nehme se ee ee ee ee ee ee ese he ee ese ee sese ese ee ee ese ee ee ee ee 26 FIGURE 10 2 VIDEO amp AUDIO SETTINGS BAOGE ees ees ees see see se ee see se ee se ee ee ee ee ee ee ese ee sese ee ee sese ee ee ee tentes ee ee Ee 27 PIGURE TI OSD SETTINGS PAGE ea se ne es afe eg Se E AG ee Ee Ee ee Gee AE IPIS OS ERGE OE ER DEE s 28 FIGURE TA CMOS SETTINGS PAGE ee eR n e tt e n ked n a e at ab kat e kk l ala n ee s 29 FIGURE 13 NETWORKING SETTING PAGE ese o ie es ee ee eie Put De See ee ie oe ee be Go de GE n ee GR EE ee eg ee Ge ie ie 31 PIGURE FE DDNS SEEFTINGTUAGE N tini aie at e ik kra a OE OE OE OE ik a alan ban d a aie 32 FIGURE 13 k SIP SETIING PACE ARK OO td de t EO OE ei kib ae 33 PGR ey SI ETIENNE TA acca css isi ol ap italik dp ka ta N e n a l a oc ude RO EO OE ON er 34 EIGUEE E55 ASE ETTING PA OE OR OT ace sah OE e ka OE EE N e ab DA kdk par 35 PUR Gy AG RO EE EE a DE RE EE RO EE EE lake 36 FIGURE 17 USER MANAGEMENT PAGE seges Ee ERGE Ge N dad l dila kt sl Se Ge sk aD Env o Qon SG lk l al GE be n RR E GESE 37 FIGURE 18 MAINTENANCE PAGE ee oe ie Ee dd E ti eti pt aa lt tak toca name ke dl e n ka e a e OE ai kt GOED a 38 FIGURER Ok MIL SINGS GB EE 4 FIGURE 192 SMIP SING AGG EE 42 EIGURE SU ING ye RE suse eka ve tn ER kk ie ae ie ake 43 FIGURE 21 PRIVACY MASKS CONFIGURATION PAGE ee esse see sees see se ee se ee ee
15. ee ee ee ee ee hei ee ee ie sese ee ee ee ee see sese ee ee 44 FIGURE 22 ALARM HTTP SERVER SETTING PAGE ccccccscccssccsscccscccsccessceesccesccesceesscesccesceusceesccesseusseesccescseusseencss 45 FIGURE 23 TIME LAPSE PHOTOGRAPHY CONFIGURATION PAGE ees ee see e see se ee se ee see ee ee ee ee ee ee ee ee ee ee ie ee ee ee 46 FIGURE 24 1 MOTION DETECTION CONFIGURATION PAGE ee ee see sees sees see see ees see ee ee ee ee tee ee ese ee ee ese ee ee ee Ee 47 FIGURE 24 2 MOTION DETECTION CONFIGURATION PAGE eege 48 FIGURE 24 3 MOTION DETECTION SCHEDULE CONFIGURATION PAGE esse ees see se ee sees see ee ee ee ee ee ee se ee ee ee ee ee ee ee ee ee 49 FIGURE 24 4 REMOTE ALARM OUT IP CAMERA CONPIOGURATION ecce eR RR he hee eere nhe reete see sre she esee reet eene 50 FIGURE 24 5 REMOTE ALARM OUT PEERING GXV3500 CONPIOGURATION 51 FIGURE 24 6 REMOTE ALARM OUT PEERING GX V3500 ACTION OUTPUT DISPLAY ees ees sees dee se ee se ee see se ee ee ee ee ee ee ee 52 FIGURE 24 7 PEERING GXV3500 DECODER ALARM OUT CIRCUTT nene ese ee reser serene eee 52 FIGURE 25 ALARM SERVER SETTING PAGE ccccccssccsscccscccssscesccescccsscessceusccusccessseesscesscesseusscusccessseesscesccessseusseesccs 53 FIGURE 26 FIRMWARE UPGRADE AND PROVISIONING cccccseccsscccsccccscccssccesccesccesceusccescsesceusceusccesceueceusceecceueceusess 54 FIGURE 27 FACTORY RESET FROM WEB INTERFACE eese eene emen hene hse tese ese ese sie sese ese sese ese ese
16. flexible HTTP API and an SDK for easy integration with other surveillance systems Designed for both indoor and outdoor environment the GXV3674 HD FHD VF v2 Day Night HD IP camera is a new addition to the popular GXV3XXX series IP surveillance product family It ensures ease of use integration and deployment with multilingual graphical user interface provides powerful solution to professional surveillance applications Ideal application scenes for GXV3674 HD FHD VF v2 are like store parking lot elevator office crossing road point and other indoor or outdoor related environments This manual will help you to learn how to operate and manage your GXV3674 HD FHD VF v2 Outdoor Day Night HD IP camera and make the best use of it Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 5 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video SAFETY COMPLIANCES These instructions are intended to assist users to safely operate the GXV361 IIR HD avoid dangerous situations or damage the device Warning May cause serious injury or death if any Caution Equipment may be damaged if any of of the warnings below are neglected the following caution messages are neglected A Warning Input voltage should meet both the SELV Safety Extra Low Voltage and the Limited Power Source with DC 12V according to the IEC60950 1 standard Please refer to the technical specifications for more deta
17. g Alternate DNS server n a Validate settings upon exit Advanced 3 Power on the GXV3674 HD FHD VF v2 4 Start the IE or Firefox browser when the network connection is up 5 Enter 192 168 1 168 in the address bar of the browser 6 The browser will ask for plug in or ActiveX if not installed otherwise it will get to Home page and start to show the video captured by the camera by default the camera enabled anonymous access 7 Click Configuration the browser will ask credentials to authorize configuration Enter the administrator user name and password to access the Web Configuration Interface the default user name and password are both set to admin 9 In step 6 IE will indicate that This website wants to install the following add on GS ViewerX cab from Grandstream Networks Inc allow the installation 10 Firefox Chrome user need to download and install the plug in to see the video the plug in is here http www grandstream com products tools surveillance webcontrl_plugin zip NOTE Please temporarily disable Antivirus or Internet Security Software when download and install the Grandstream Firefox plug in for video or GSViewerX cab for Microsoft Internet Explorer Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 18 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video GXV3674 HD FHD VF v2 APPLICATION SCENARIOS GXV3674 HD
18. mask configure and save the configuration When privacy mask enabled the video at related region will be masked by black color and no video displayed inside that mask Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 44 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 dstream Innovative IP Voice amp Video Alarm Server Settings Page Upload Alarm to supported VMS or HTTP Server This page allows user to configure alarm HTTP server to upload alarms Upload Alarms to VMS platform supported or HTTP Server for processing Alarm HTTP Server Settings Server Name Security Solution URL server911 cloud net9999 User Management User Name subscriber_110 Maintenance Password POTEET ETE SMTP FIP Save Privacy Masks Alarm Server Time Lapse Photography Figure 22 Alarm HTTP Server Setting Page Server Name The name of HTTP server or VMS system URL URL of the Server User Name User ID from that Server Password Password for that User ID NOTE gt Grandstream provide HTTP API to help third party companies by using HTTP server or VMS to develop further solutions for their customers http www grandstream com products surveillance general documents grandstream http api pdf gt Grandstream IP Camera and DVS including GXV3674 HD FHD VF v2 are ONVIF certified Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 45 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 dstream
19. of H 264 please refer to http en wikipedia org wiki H 264 MPEG 4_AVC gt IfMJPEG selected reduce max frame rate to min value to save bandwidth and get better image gt Grandstream IP Camera provides two video streams user can use them with flexibility For example the high resolution stream for local recording another low or high resolution for remote monitoring or vice versa depending application scenarios gt Use below link to calculate bandwidth and storage before installation http www grandstream com support tools bandwidth storage calc Audio Settings Preferred Audio Codec PCMU vi a Microphone Volume n 25 Speaker Volume ed SE Light Condition Outdoor Light Condition Indoor 50Hz Power Frequency Indoor 60Hz Power Frequency Save Figure 10 2 Video amp Audio Settings Page e Audio Settings o Preferred Audio Codec PCMU PCMA AAC supported Audio also can be disabled o Microphone Volume Slide to adjust microphone gain o Speaker Volume Slide to adjust the speaker volume connected e Light Condition Select correct light condition for the scene monitored Outdoor Indoor 50Hz power frequency Europe China etc or 60Hz power frequency US Japan etc Wrong setting will affect image quality under fluorescence light condition Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 27 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 OSD Setting Page
20. policy without prior notification A Caution Changes or modifications to this product not expressly approved by Grandstream or operation of this product in any way other than as detailed by this User Manual could void your manufacturer warranty Please do not use a different power adaptor with the GXV3674 HD FHD VF v2 as it may cause damage to the products and void the manufacturer warranty e This document is subject to change without notice The latest electronic version of this user manual is available for download at http www grandstream com products surveillance GXV3672hd documents gxv3672hd fhd usermanual english pdf Reproduction or transmittal of the entire or any part in any form or by any means electronic or print for any purpose is not permitted without the express written permission of Grandstream Networks Inc Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 8 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 W nn CONNECT YOUR GXV3674 HD FHD VF v2 Equipment Package Contents The GXV3674_HD FHD_VF v2 package contains GXV3674 HD FHD VF v2 IP Camera 12V DC Universal Power Adaptor Ethernet Cable Hex Key and 4 Screws and Wall Anchors Quick Installation Guide and GNU GPL license X GXV3674 HD FHD VF x 12V Power Supply uu 6 Pas S SS Py x Ethernet Cable 4 x Wall Anchors pi Av Screws 1 x Hex Key x Quick Start Guide x GPL License Grandstream Networks Inc G
21. provider e Outbound Proxy IP or FQDN of Outbound proxy server helps penetrate NAT Firewall e SIP User ID SIP username or telephone number from ITSP e Authenticate ID Authenticate ID used by SIP proxy e TEL URI URI or Phone selection by ITSP see webpage help tips e Authenticate Password Authenticate password used by SIP proxy e STUN Server STUN server used to resolve NAT if have e Steam Which stream used for SIP call Default 2 stream strongly recommended due to bandwidth and data involved at video call e Preferred Vocoder Audio codec used for SIP call only G 711 A or U supported e Registration Expiration Registration expiration time default 3600 seconds e Local SIP Port Local SIP port default 5060 e Local RTP Port Local RTP port for media default 5004 Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 33 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 Auto On Hook Timer Enable Keep Alive Accept Direct IP Call SIP Transport SIP TLS Certificate SIP TLS Private Key Save Figure 15 2 SIP Setting Page Disable Audio in SIP Call Enable White List Number Filter Enable two way Audio Warning Mode SIP Proxy Compatibility Mode Sel defined Warning Audio dstream Innovative IP Voice amp Video oe di man UDP TCP TLS TCP Delete Delete SIP TLS Private Key Password sess Upload Delete e Auto On Hook Timer Timer seconds for automa
22. 0 9096 RH non Temperature Humidity condensing Storage 30 C 60 C 22 F 140 F Power Adapter Output 12VDC 1A Input 100 240VAC 50 60HzZ IP66 compliant weather proof metal case FCC Part 15 Subpart B Class B EN 55022 Class B Compliance EN 61000 3 2 EN 61000 3 3 EN 55024 EN 60950 1 C tick AS NZS CISPR 22 IP66 Table 1 GXV3674_HD FHD_VF v2 Technical Specifications Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 12 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video INSTALLATION GUIDE Minimum Recommended Computer System Requirement To install GXV36 4 HD FHD VF v2 you will have a computer PC recommend The minimum recommended PC system reguirement listed below e Windows XP Windows Vista Windows 7 and Windows 8 e CPU Intel Pentium 4 or higher 2 GHz e RAM 2 GB 4 GB recommended for larger systems e Support for DirectX 8 0 and above Configure the GXV3674_HD FHD_VF v2 via Web Browser The GXV3611IR HD has embedded Web server to respond to HTTP GET POST requests Embedded HTML pages allow user to configure the IP camera through Microsoft Internet Explorer 7 0 or above Firefox Chrome plug in from Grandstream required e Download WebControl Plug in from Grandstream website http www grandstream com products tools surveillance webcontrl_plugin zip For Apple platform OS X only MJPEG video coded supported currently NOTE
23. Ae Innovative IP Voice amp Video Grandstream Networks Inc GXV3674 HD VF GXV3674 FHD VF v2 Outdoor Day Night Vari focal HD IP Camera m m Sey GXV3674 HD FHD VF v2 User Manual www grandstream com Firmware Version 1 0 3 5 http esupport grandstream com andstream Innovative IP Voice amp Video This page intentionally left blank Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 2 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video TABLE OF CONTENTS GXV3674 HD FHD VF v2 User Manual UR ONIE EE IE EO M EMI RUINIS EA EA EE NE E 5 PFEF COME ITANC SPEEN EE OE N l aj SR ke OE N N ee EO ak kk n kak kk a 6 FOGGAIYTION kot EE EE EN N OE EE N sejou OER EE 7 RF EXPOSURE INFORMATION GA 7 ass TE OE IE N EE NN EA AE IR EE RA RT OUE DEE EN N EN 8 CONNECT YOUR GXV3674 HD FHD VF V2 isdie sedes sies sweis Ku MESE ese ees deed see in e ed kk de De ewe 9 EQUIPMENT PACKAGE GONTENTS esse ese see see ees dee se dee se dee ee ee ee ee ee dee ek ee ee GR ee ee ee ee ee ee ee andan asado ee ee 9 CONNECTING THE GXV3674 HD FHD VE VO ees esse see ee see ee ee ee ee ee ees ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee Ee ee 10 PRODUCT OVERVIEW m 11 GXV3674 HD FHD VF V2 GAMERA ese ees ee ee ee ee ee mI ee ee ee ee ee ee ee ee ee ee ee ee ee nsn nias snas rsen ee ee nsn ee ee 11 GXV3674 HD FHD VF V2 SPECIFICATIONS ee ees see see ee see ee ee ee see e
24. On Screen Display O SD OSD Text System OSD Position Video amp Audio OSD Date Format Display Time CMOS Settings B Display Text Networking DDNS Save SIP Status Figure 11 OSD Settings Page e On Screen Display OSD o OSD Text OSD Position OSD Date Format Display Time Display Text O O DO stream Innovative IP Voice 4 Video Front Door Bottom vi MM DD YYYY lw m Display time stamp and text on the video screen Inputted text to identify the camera shown on the screen Show the OSD in either top or bottom position on screen OSD Date format choose based on user preference When checked time will be displayed inside the video image When checked inputted text will display on video image Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 28 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video CMOS Settings Page This page allows user to adjust the CMOS parameters CMOS Parameters Configuration System Video amp Audio OSD CMOS Settings Networking DDNS Flip NONE Shutter Speed Auto M IR LED Setting Auto IR CUT Setting Automatic IR sensor control l IR CUT Sensitivity 3 Color Mode Auto M WDR Of E Save Figure 12 CMOS Settings Page e Flip Pull down to choose video flip either vertically or horizontal or both Shutter Speed Camera Shutter Speed There are 10 opti
25. P Settings Page Upload Alarm This page allows user to configure FTP parameters to upload the alarm or video recording FIP Settings Enable FTP Iv FTP Server myftp cloud net FIP Server Part 21 User Name subscriber12 Password TETIT Fath AarmRecording Valid DNS server is required for hostname Save Test Figure 20 FTP Setting Page e Enable FTP When checked built in FTP client is enabled e FTP Server IP or Domain name of FTP site or server e FTP Server Port TCP port for FTP server default port number 21 e User Name FTP server User ID e Password FTP server user password e Path Path in the server where upload files are stored NOTE gt Click Save to save the FTP configuration information gt Click Test after configuration if setting is correct a test FTP operation will be performed and Test successful yellow bar will display if the operation is successful Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 43 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 dstream Innovative IP Voice amp Video Privacy Masks This page allows user to configure privacy masks up to 4 different regions Privacy Masks ES p 9 x Region ID Enable P z User Management 1 Ir 2 O Maintenance 3 C Privacy Masks Alarm Server Time Lapse Photography Motion Detection Syslog Figure 21 Privacy Masks Configuration Page Select different region requiring privacy
26. Upto 15 M seconds Voice Alarm to SIP Phone Upload to Alarm Center Upload to Alarm HTTP Server Record Video and Upload to FTP Server Email and FTP upload JPEG Pre Alarm Upto 1 M seconds to After Alarm Upto 1 vi seconds Time Schedule Config Figure 24 2 Motion Detection Configuration Page Alarm Action e Record Video From Pre Alarm Up to XXX seconds to After Alarm Up to XXX seconds This setting to allow configure pre post alarm video for applications to utilize MJPEG is NOT supported for this feature e Voice Alarm to SIP Phone If SIP server or peer IP device configured check this will allow MD event to trigger alarm SIP call to pre configured number e Alarm Output Select will allow MD to send alarm to Alarm Output interface e Upload to Alarm Center When checked the alarm video will be transferred to Alarm Center like Grandstream free GSurf _Pro VMS software When peering with GXV3500 Decoder for Remote Alarm Out this field has to be selected e Upload to Alarm Center When checked MD alarm will be sent to 3 party Alarm Center e Upload to Alarm HTTP Server When checked MD alarm will be send to 3 path HTTP server via Grandstream HTTP API e Record Video and Upload to FTP Server When checked and FTP server configured the recorded video will be send to the configured FTP server e Email and FTP upload JPEG When checked snapshots of trigger moment will be emailed to pre configured email account and
27. V3611IR HD 3 Bonjour will now display embedded at Safari Select Bonjour pull down menu and select Webpages the related IP Camera like GXV3674 HD FHD VF v2 will be there Is ed TENET 2 o O or enter an addres am EH Bonjour M Mission 272 endra Modi Buy Cool F ewakoof com gt 40 Things E Should 1 a About Bonjour b 2 m Webpages Figure 4 2 Apple Safari Bonjour Setting page to display GXV3674 HD FHD VF v2 4 Click the displayed camera to access to the configuration page of the camera Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 16 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video 5 To see the video user has to change the video codec from default H 264 to MJPEG NOTE The instruction given here based on Safari OS X other Apple platform like iOS iPhone iPad can use similar method e OO About This Mac OS X Version 10 9 4 Software Update Safari Version 7 0 5 9537 77 4 Memory 8 GB 1600 MHz DDR3 More Info Copyright 2003 2014 Apple Inc All rights reserved Processor 2 5 GHz Intel Core iS TM and 1983 2014 Apple Inc All Rights Reserved License Agreement gt iPhone iPad iOS users are recommended to use Applications in Apple Store Free or Paid applications from Apple Store like IP Cam Viewer are suggested and verified worki
28. XV3674 HD FHD VF v2 User Manual Page 9 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video Connecting the GXV3674 HD FHD VF v2 Using the Power Adapter as power supply gt Connect the RJ 45 Ethernet cable to the NETWORK port of the GXV3674 HD FHD VF gt Connect the other end of the RJ 45 cable to your network switch or router or PC gt Connect the power supply to the DC 12V power jack on the back of the GXV3674 HD FHD VF Using PoE as power supply gt Connect the RJ 45 Ethernet cable to the NETWORK port of GX V3610_HD FHD v2 gt Connect the other end of the RJ 45 cable to your PoE switch gt PoE injector can be used if PoE switch is not available Please refer to following connection diagram to hook up the camera 3 5mm Audio Out w l LA Audio In HM Ports emm Network w Port Option A Power Adapter lo AC Outlet Option B RJ45 Ethernet Cable To Power over Ethernet PoE Switch NOTE Choose Option A if using the power supply or choose Option B if using a Power over Ethernet PoE switch Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 10 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video PRODUCT OVERVIEW GXV3674 HD FHD VF v2 Camera Figure 1 GXV3674 HD FHD VF v2 Illustration 1 Screw and Top Cover GXV3674 HD FHD VF v2 screw and Top Cover Plate 2 IR LED Light IR LED light array fo
29. XV3674 HD FHD VF v2 web interface Internet Explorer will indicate that this website wants to install to following add on GSViewer cab from Grandstream Networks Inc Please install this add on when prompted by IE 3 How do you manually uninstall the Grandstream video viewer add on for IE Please follow these steps to uninstall the add on 1 Delete the GSViewerX Control from C WINDOWS Downloaded Program Files directory 2 Delete GSNetClient dll GS Replay exe GSViewerX ocx hi_h264dec_w dlll lik VoiceEngine dll dll and GSViewerX inf from C WINDOWS system32 d Why can t access the GXV3674 HD FHD VF v2 web configuration interface Q 1 Is your internet service down A 1 Connect a PC to the internet to test the connection Q 2 Are the PC and the device in different subnets A 2 Check the subnet mask and default gateway of the device and PC Q 3 Is there a conflict with another IP address A 3 Try to change the IP address of the device Q 4 Has the HTTP port been changed A 4 Contact the administrator of the device for more information 5 The GXV3674 HD FHD VF v2 web configuration page is not displayed correctly in IEG In IE8 Compatibility View might need to be enabled for the GXV3674 HD FHD VF v2 web configuration page to load properly To enable compatibility view open IE8 click Tools Compatibility View Setting and add the GXV3674 HD FHD VF v2 web configuration pages to the Compatibility View 6 Why does IE in
30. at System setting page of GXV3500 Decoder See below the figure When Alarm Out taking action the webpage will show the related action For example below the Digital Output Duration is selected as 15 seconds so the Alarm Out will act for 15 seconds before revert back to previous state In below case the default 1s circuit Open when Motion Detection alarm triggered the circuit state changed to Close as illustrated below for 15 seconds and then switch back to previous Open state Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 51 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video Current System Time 2015 02 04 16 28 25 Sync With PC Set Manually Time Zone GHT OS New York Toronto Washington DCH A Enable Daylight Saving Time Start Time Mar kad Second Sunday 2 Hour End Time Nov First Sunday 2 Hour F Enable NTP NTP Server time nist gow NTP Update 5 1440 Interval Minutes _ Save OSD Date Format OSD Date Format YYYY MM DD _Save DI and DO Digital input Normal Open Current state is Open Digital output Normal Open E Current state is Close Alarm Output Duration 15 seconds Save Figure 24 6 Remote Alarm Out peering GXV3500 Action Output Display Unlike the Alarm Out interface of Grandstream IP Camera which using relay switch the GXV3500 Alarm Out is using photo coupler circuit If connectin
31. ck the proper H 264 decoder to play the recorded video Please download the Microsoft FFDShow H 264 decoder from http sourceforge net projects ffdshow tryout and install it 10 Alarm Triggered Events do not work with GSurf_Pro Please double check the Alarm Action on your GXV3674 HD FHD VF v2 Login to the web GUI of the GXV3674 HD FHD VF v2 go to the Motion Detection or Alarm Events page and make sure option Upload to Alarm Center is checked 11 Recommended to save the video files in different directories when using GSurf_Pro It is better to save video files in different directory to prevent accidental deletion of the recorded files you need 12 How to use a Cell phone to watch the GXV3674_HD FHD_VF v2 video stream You must set the video resolution to QCIF to watch the GXV3674 HD FHD VF v2 video stream from a cell phone Make sure to set the bit rate to 64kbps to ensure the best video quality 13 What Smartphone application should I use to view the video There are free applications and paid version application for this you can find them in Google Play for Android phone and Apple Store for iPhone like IP Cam Viewer http hit mob com Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 58 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 clean Innovative IP Voice amp Video 14 Why the IP address of the device NOT reset when clicking the Restore button The GXV3674 HD FHD VF v2 could be i
32. dicate to install Grandstream Video Viewer add on after a firmware upgrade The add on was properly installed before the firmware upgrade process New firmware will often upgrade the add on as well To watch the live video stream you must install the newest version of the add on Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 57 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 andstream 7 How do you watch secondary video stream Login to the home page of the GXV3674 HD FHD VF v2 web GUI click Play to watch the video stream To watch a secondary video stream right click on the video and select Secondary Stream on the pop up menu Try reinstalling the Grandstream Viewer add on for IE if you cannot see the video stream 8 What is DDNS Is it important for IP surveillance product to have DDNS support DDNS is an acronym for Dynamic Domain Name Service It is important to choose an IP network camera that has DDNS support for dynamic IP addresses Chances are that the network has a dynamic IP address which changes with every log on A DDNS service makes sure that the camera s IP address always matches up to the current server address DDNS also allows a website to be linked to the IP camera that is constantly updated with the correct information and has a reliable feed 9 Why is Windows Media Player unable to play the recorded video files The GXV3674 HD FHD VF v2 uses the H 264 video codec Windows Media Player may la
33. e Restart Restore the Device Reset Settings except IP Address to Factory Default Restore Firmware Upgrade and Provisioning Upgrade via Firmware Server Path Config Server Path XML Config File Password HTTP firmware grandstream com config grandstream com Automatic Upgrade Interval Minutes 10080 DHCP Option 66 Override Server 3CX Auto Provision m Automatic Upgrade Iv Save System Access Disable Telnet E Enable UPnP Discovery Iv Save Figure 18 Maintenance Page e Restart When clicked the camera will reboot or restart soft reboot e Restore When clicked the camera will be reset to factory default wiping out all the configurations except IP address e Upgrade via Upgrade firmware via TFTP HTTP or HTTPS e Firmware Server Path Server path holding the firmware e Config Server Path Server path holding the configuration file auto provisioning e XML Config File Password Password for encrypt the XML based configuration file e Automatic Upgrade Interval Minutes Time interval for automatic upgrade default 10080 e DHCP Option 66 Override Server Enabled to redirect firmware configuration server path Enabled to use 3CX as SIP server to auto provisioning the device Checked to enable automatic firmware upgrade and provisioning e 3CX Auto Provision e Automatic Upgrade GXV3674 HD FHD VF v2 User Manual Firmware Version 1 0 3 5 Grandstream Networks Inc Page 38 of 59
34. e 1 e GXV3610 HD O00b 260bcfb CXV36 15WPI HD 000b82609c9e CXV3672 FHD 000b825ce0ae GXV3672_FHD 000b8263bc6b Figure 2 Windows Network showing GXV3674 HD FHD VF v2 as Other Devices via UPnP e Click the displayed icon of related IP camera the default browser eg Firefox or Chrome will open and connect directly to the camera s webpage prompt message will display asking for plug in installation e Disable security or antivirus software download the plug in close browser and install the plug in open the browser again the embedded video will be displayed if clicking the icon of the related IP Camera B GS Search Utility Tool User can know the IP address assigned to the camera from DHCP server log or using the Grandstream GS Search tool Following is the instruction for using GS Search utility tool 1 Download the GS Search tool from Grandstream website http www grandstream com products tools surveillance GS Search zi 2 Run the Grandstream GS Search tool by double click the unzipped GS Search exe 3 Click on the Sea Luc to begin device detection The detected devices will appear in the output field like below Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 14 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 clean Innovative IP Voice amp Video Index Model Liest DeviceName Ip nt RTSPPot MAC i MVA GYR SSS0EP2 1 0 7 7 GWA 192 165 22 57 DU Sek
35. e Access Optional Figure 5 2 GXV3674 HD FHD VF v2 Working with GVR3550 and or GSurf Pro with Internet Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 20 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video GXV3674 HD FHD VF v2 Application Peripheral Connection Below is the illustration of GXV3674_HD FHD_VF v2 peripheral connections for related application d SE Audio Out xi gt Celing Speaker Audio In I Remote Peering Two way Audio amp Video via Network 4 Ssrens Grandstream Video Phone GXV354H Decoder Figure 6 Application Peripheral Connection for GXV3674 HD FHD VF v2 NOTE Audio Output Amplified Speaker using 3 5mm interface and must match below impedance parameter Audio Input 3 5mm Line In 15000 0 1Vrms 0 707Vrms Audio Output 3 5mm Line Out 6000 0 707Vrms gt Grandstream Video Phone can work with GXV3674 HD FHD VF v2 via either Peer IP LAN or SIP extension WAN Peer to Peer or Direct IP works only at LAN using static IP SIP extension requires related SIP server proxy provided and configured Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 21 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 andstream Innovative IP Voice amp Video This page intentionally left blank Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 22 of 59 Firmware Version 1 0
36. e dee se dee ee ee ee ee ee ee ee ee ee ee ee ee rna ee 12 INSTALLATION GUIDE 2E N OE OE ER OE OE N OE OE EI ON EN 13 MINIMUM RECOMMENDED COMPUTER SYSTEM REOUIREMENT oes ese ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee 13 CONFIGURE THE GXV3674 HD FHD VF V2 VIA WEB BROWSER ee ees ees ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee 13 CONNECT THE CAMERA TO NETWORK WITH DHCP SERVER RECOMMENDED sesse ese se eene 14 Windows IP AL OUI RE 14 aieo Bde ER N ORE EE RE ER EO kk kk a a a kk 16 CONNECT TO THE CAMERA USING DTATICIR nnn nnne nnne nnne nsn rennen 18 GXV3674 HD FHD VF V2 APPLICATION SCENARIOS 14 see see ees sek ees Ek ke e nhanh amara iara ua Ek ka 19 EE eda zz TT m 19 LAN WITH INTERNET ee pot OR a lt pt EE RA OE AK EE EA ON 20 GXV3674 HD FHD VF v2 APPLICATION PERIPHERAL CONNECTION 21 GXV3674 HD FHD VF V2 HOME WEB PAGE ees see e ese ees se ee sk ee kk nnn nnn eek ee eek nura nana uana ee ee ke aaa ka 23 GXV3674 HD FHD VF v2 CONFIGURATION amp LANGUAGE DAG 24 BASIC SETTINGS EXPLANATION A esse aaa ea aaaaenosasossaaonssaossssosososososososososososonosossosososososososososososanononun 25 SYSTEM SETTINGS PAGE E 25 VIDEO amp AUDIO SETTING PAGE as es pt ta te pt Ge be N ok AANE E n ED ve Ge EE a 26 GED Re Ne 28 GMOS SST TINGS PAGE sei ata gwosi E Umm 29 NETWORKING SETTING GE 31 KRIER Tee GE 32 IP ETING FACE oes kat fe seers ye A e e m I
37. ee ese ee esse dee ee ee se ee ee se ee ee ee ee ee ee ee ee ee ee ee ee seges ee ee ee ee Re ee EE ee Ee ee 56 IP SURVEILLANCE F EEN 57 Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 3 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 clean Innovative IP Voice amp Video TABLE OF FIGURES GXV3674 HD FHD VF v2 USER MANUAL FIGURE I GXVI674 HD EHD VE V2 ILLUSTRATION Aere 11 FIGURE 2 WINDOWS NETWORK SHOWING GXV3674 HD FHD VF V2 AS OTHER DEVICES VIA UPNP 14 FIGURE 3 GS SEARCH RESULT PAGE OF GXV3674 HD FHD VF V2 ees ees ee sees se ee see ee se ee ee ee ee ee ee ee ee ee ee ee ee ee ee 15 FIGURE 4 1 APPLE SAFARI BONJOUR SETTING PAGE TO DISPLAY GXV3611IR HD ees ese see see ee ee ees ee ee 16 FIGURE 4 2 APPLE SAFARI BONJOUR SETTING PAGE TO DISPLAY GXV3674 HD FHD NEW 16 FIGURE 5 1 GXV3674 HD FHD VF V2 WORKING IN LAN 19 FIGURE 5 2 GXV3674 HD FHD VF V2 WORKING WITH GVR3550 AND OR GSURF PRO WITH INTERNET 20 FIGURE 6 APPLICATION PERIPHERAL CONNECTION FOR GX V3674 HD FHD WEN 21 FIGURE 7 HOME PAGE OF GXV3674 HD FHD VEV2 ees ees ese see I se ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee 23 FIGURE 8 WEB LANGUAGE SWITCH ee ees ee see see sees see ee ees ee ee ee he ee ese ie ese ese ee sese ese ee sese eee ee sese ee ee ee eee ee ee ee ee 24 FIGURE 9 SYSTEM SETTINGS PAGE iss bose ie es bal s ijan Ge Ge Ge ee be ee Oe Ge ee e De Ge
38. en stop audio from the camera s microphone Toggle to talk to camera s speaker computer microphone required Click to playback the recorded video file Click to configure the file path of snapshot and recorded video files Also adjust the video delay or smoothness If configured motion detection alarm triggered the indicator will flash in red Click the indicator icon to turn off the alarm indication GXV3674 HD FHD VF v2 User Manual Page 23 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 dstream Innovative IP Voice amp Video GXV3674_HD FHD_VF v2 Configuration amp Language Page e When click the Configuration tab web page will link to page to configure the related parameters of the GXV3674 HD FHD VF e There are two big categories of settings Basic Settings and Advanced Settings Details will be illustrated in the later Chapter e When click the Language tab supported languages will be displayed in Figure 2 Click to select the related webpage display language Configuration il EB AA ee m English Pyccen Figure 8 Web Language Switch e Currently firmware only support English default Simplified Chinese and Russian Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 24 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video BASIC SETTINGS EXPLANATION System Settings Page This page allow user to configure the system settings o
39. ent is known as the Specific Absorption Rate SAR and the SAR limit set by FCC is 1 6 W kg This device 1s complied with SAR for general population uncontrolled exposure limits in ANSI IEEE C95 1 1992 and has been tested in accordance with the measurement methods and procedures specified in OET Bulletin 65 Supplement C This device has been tested and meets the FCC RF exposure guidelines when tested with the device directly contacted to the body RF exposure compliance with anybody worn accessory which contains metal was not tested and certified and uses such body worn accessory should be avoided Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Hereby Grandstream declares that this device 1s in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 7 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 clean Innovative IP Voice amp Video WARRANTY If you purchased your GX V3674_HD FHD_VF v2 from a reseller please contact the company where you purchased the device for replacement repair or refund If the device was purchased directly from Grandstream please contact our technical support team for a RMA Return Materials Authorization number before the product is returned Grandstream reserves the right to remedy warranty
40. f GXV3674 HD FHD VF v2 VE Administration interface Set the System Tim Current System Time 2015 02 04 22 15 03 Sync With DC Set Manually System Time Zone GMT 05 New York Toronto Washington DC vi Video Audio lw Enable Daylight Saving Time OSD Start Time Mar vi Second vi Sunday 2 Hour CMOS Settings x End Time Nov M First M Sunday 2 Hour Networking DDNS Enable NTP SIP NTP Server time nist gov Status E Update Interval Minutes 60 5 1440 Save Device Setting Device Name GXV3674 FHD VF Save Figure 9 System Settings Page e Current System Time Display time current system is running at o Syne with PC Click to synchronize current time with computer o Set Manually Click to manually set the current time and date e Time Zone Select from pull down menu the time zone unit located o Enable DST Configure Day Light Saving Time o NTP Enable and configure NTP server and update interval e Device Name Set the name of the camera which will be shown in the result of Search Tool of GSurf Pro VMS program NOTE gt Save button has to be clicked to save all the changes made to the device Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 25 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video Video amp Audio Setting Page This page allows user to configure the video and audio related settings Video Se
41. f the camera Please BACKUP or PRINT out all the settings before approach to following steps Grandstream will not take any responsibility if you lose all the parameters of setting or cannot connect to your VoIP service provider Reset from Web Interface This page allows user to configure dynamic network related parameters n EE TT Restart the Device Restart the Device Restart Restore the Device User Management Maintenance Reset Settings except IP Address to Factory Default SMIP FIP l Firmware Upgrade and Provisioning Privacy Masks Alarm Server Upgrade via HTTP M Time Lapse Photography Firmware Server Path firmware grandstream com Motion Detection Config Server Path config grandstream com Syslog XML Config File Password sesenn Automatic Upgrade Interval Minutes 10080 DHCP Option 66 Override Server DI 3CX Auto Provision D Automatic Upgrade Iv Figure 27 Factory Reset from Web Interface Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 56 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 andstream Innovative IP Voice amp Video IP SURVEILLANCE FAQ 1 What is the default IP address of the GXV3674_HD FHD_VF v2 The default IP configuration is DHCP or 192 168 1 168 after booting up 5 minutes 2 Why can not view the live video stream in Microsoft Internet Explorer Please double check whether the Grandstream Plug in Active X is installed correctly Once you log into the G
42. g to a multi meter you will see the Ohm changed from unlimited to several hundred Ohms depending on GXV3500 HW version Alanm out Figure 24 7 Peering GXV3500 Decoder Alarm Out Circuit Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 52 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video Syslog Settings Page Troubleshooting Help This page allows user to enable the Syslog to help troubleshooting problems SysLog Settings Syslog Server syslog Level C d ebug gave ee User Management Maintenance SMTP FIP Privacy Masks Alarm Server Time Lapse Photography Motion Detection Syslog ma Figure 25 Alarm Server Setting Page e Syslog Server Syslog server IP or Domain Name e Syslog Lever Lever of syslog message sent to the syslog server None Debug Info Warning Error Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 53 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 CC inn Innovative IP Voice amp Video Software Upgrade This page allows user to configure firmware upgrade Software upgrade can be done via TFTP HTTP or HTTPS The corresponding configuration settings are in the ADVANCED SETTINGS configuration page Restart the Device Restart the Device Restart User Management Restore the Device Maintenance Reset Settings except IP Address to Factory Default SMTP Restore FTP Firmware
43. ils Do not use a third party power adapter or power cord When the device installed on the wall or ceiling make sure that it is firmly attached A Caution e Make sure that the power supply voltage is correct before using the camera e Do not drop the device or expose it to physical shock e Do not expose the device to temperatures outside the range of 20 C to 50 C when the device 1s in operation e Do not expose the device to damp wet conditions or high electromagnetism radiation e To avoid heat accumulation make sure that your operating environment has proper ventilation e Do not damage the warranty sticker A few parts e g electrolytic capacitor of the equipment shall be replaced regularly according to their average lifetime The average lifetime varies from the differences between operating environments and usage history Regular maintenance checks are recommended for all users Please contact your dealer for more details Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 6 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 clean Innovative IP Voice amp Video FCC CAUTION Any Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must
44. n Detection can use the GX V3500 built in Alarm Out interface if there are multiple RTSP URL configured in the GX V3500 Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 50 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video A san GXV3500 Decode Mode Administration Interface Encode Home Page Configuration Language Decoder Settings Stream Format RTSP vi Default Stream 2 vi Enable Patrol 1 Video Output Type Auto or NTSC vi Real Size rtsp 192 168 11 63 10020 4 No Patrol RTSP URL User Name Password Description Timels 1E T rspy192168 11 69 10020 4 admin TTT GXV3615WP_HD 60 245 T rmspi92 1681171100604 GXV3610_FHD 34 N 60 Figure 24 5 Remote Alarm_Out peering GXV3500 Configuration NOTE gt GXV3500 is designed to work with analogue camera therefore resolution more than DI NOT supported this is why 2 stream decoding usually less than D1 used as peering for remote Alarm Out The RSTP setting will be rtsp IPCamera Port A 4 is 2 stream of GXV3672 gt 2 stream also consume less bandwidth therefore good for internet transmission gt H 264 video codec has to be selected because Motion Detection not supported via MJPEG gt All Grandstream IP Cameras without built in Alarm Out interface can peer with GX V3500 Decoder Mode built in Alarm Out interface for Motion Detection Remote Alarm Out Alarm Out duration can be configured
45. nd password to access the Web Configuration Interface the default user name and password are both set to admin 9 In step 6 browser will indicate that This website wants to install the following add on GS ViewerX cab from Grandstream Networks Inc Please allow the installation 10 The plug in can be download here http www grandstream com products tools surveillance webcontrl_plugin zip Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 15 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 dstream Innovative IP Voice amp Video APPLE PLATFORM For Apple users please turn on Bonjour of Safari to find and access the GX V3674_HD FHD_VE v2 1 Open Safari select Advanced to open the Advanced Setting 2 Click Include Bonjour in the Bookmarks menu and Include Bonjour in the Favorites bar then close the setting page and back to Safari e oo Advanced A ww FT A General Tabs AutoFill Passwords Security Privacy Notifications Extensions Accessibility Never use font sizes smaller than 9 Press Tab to highlight each item on a webpage Option Tab highlights each item Internet plug ins k al Stop plug ins to save power Plug ins start automatically on B websites Details Style sheet Mone Selected Default encoding Western ISO Latin l Proxies Change Settings Show Develop menu in menu bar 7 Figure 4 1 Apple Safari Bonjour Setting page to display GX
46. ng with Grandstream IP Cameras like GXV3674_HD FHD_VF v2 Apple Store applications like IP Cam Viewer will support H 264 video codec Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 17 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video Connect to the Camera using Static IP If no DHCP server in the network or the camera does not get IP from DHCP server user can connect the camera to a computer directly using static IP to configure the camera The default IP if no DHCP server or DHCP offer time out 3 minutes is 192 168 1 168 1 Connect the computer RJ 45 via an Ethernet cable directly to the IP camera GXV3674 HD FHD VF v2 2 Configure the computer using Static IP 192 168 1 XXX 1 lt XXX lt 255 but NOT 168 and configure the Subnet mask to 255 255 255 0 Leave the Default Gateway to Blank like below 2 x Internet Protocol Version 4 TCP IPv4 Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically e Use the following IP address IP address 192 168 1 10 Subnet mask 255 255 255 0 Default gateway C Obtain DNS server address automatically e Use the following DNS server addresses Preferred DNS server i
47. nge the default HTTP port from 80 to 6056 to make sure the TCP port not likely blocked gt In addition to HTTP port RTSP port is also required to configure via port forward so remote party can view the video stream gt If revise the default TCP port SO to port A then RTSP port should be 2000 A changed from default TCP 554 Both TCP port A and 2000 A should be configured for port forwarding in the router For example the HTTP port changed to 8088 the RTSP port now should be 10088 both TCP ports S088 and 10088 should be configured for port forwarding in order for remote camera access 8088 for web portal 10088 for video streaming Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 31 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video DDNS Settings Page This page allows user to configure dynamic DNS related parameters be C N Em ER See GXV3674 FHD VE Administration Interface danstan Dynamic DNS Settings DDNS Active O DDNS ISP Type dyndns org System Video amp Audio Sel Define DONS Address OSD Site Name CMOS Settings DDNS Account Networking DDNS DDNS Password ELETI SIF STUN Server Status Save Figure 14 DDNS Setting Page e DDNS Active Enable DDNS by check this field e DDNS ISP Type Select the DDSN service provider from the pull down menu list e Self Define DDNS Address I
48. nput the self defined DDNS address e Site Name DDNS site name e DDNS Account DDNS account name e DDNS Password DDNS password e STUN Server Stun server FQDN or IP If device behind a non symmetric router STUN server can help to penetrate amp resolve NAT issue Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 32 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 dstream Innovative IP Voice amp Video SIP Setting Page GXV3674 HD FHD VF v2 can be configured as SIP endpoint to call out when alarm trigged or allow permitted number to call in to check the video if Grandstream video IP phone is used General Phone Settings Registered Offline Unregister On Reboot FI s SIP Settings Vid o A Audio CMOS Settings Account Name IPPBX SIP Server gs ucm isp com Networkimn L Outbound Proxy SIP User ID 6175669300 Authenticate ID 0038665716 Authenticate Password ELE STUN Server mystun freebox net Stream Secondary Preferred Vocoder PCMU Register Expiration Second 3600 Local SIP Port 5050 Local RTP Port 5004 Figure 15 1 SIP Setting Page e Registered SIP registration status Display Online in Green Offline in Red e Unregistered on Reboot If checked and SIP server support reboot camera will unbind all registered end points using this SIP account e Account Name SIP account name used for self identification e SIP Server FQDN or IP of SIP server from VoIP service
49. nstalled in areas that are not easy to access For example it could be installed on the roof of a building or the ceiling of an office This makes it difficult to reinstall the device therefore the Restore function will not clear the IP address 15 Why can t the live video stream be viewed using a mobile phone or GSurf_Pro after changing the HTTP Port of the device Make sure that the RTSP port of the device is set to 2000 plus the HTTP Port number For example if the HTTP port is 88 then the RISP port of the device that you configured on GSurf_Pro or mobile phone should be 2088 16 Port forwarding Two ports must be forwarded on your router to watch video from a GXV3674 HD FHD VF v2 that is located on a private network from a PC in a public network The web port HTTP and the RTSP port Please make note that the RISP port number changes according to the web port If the web port is 80 then the RTSP port is 554 If the web port is not 80 then the RTSP port equals the web port 2000 For example if the web port is 88 then the RISP port will be 2088 Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 59 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015
50. nt ee ee 56 TABLE OF TABLES GXV3674 HD FHD VF v2 UsER MANUAL TABLE 1 GXV3674 HD FHD VF V2 TECHNICAL SPECIFICATIONS ERROR BOOKMARK NOT DEFINED Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 4 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice amp Video WELCOME Thank you for purchasing Grandstream s GX V3674_HD FHD_VF v2 Outdoor Day Night High Definition IP Camera an innovative powerful weatherproof infrared next generation network camera Its advanced ISP Image Sensor Processor powered with state of the art auto exposure auto white balance algorithm and a high quality lens ensures high fidelity video quality that matches digital still camera color grade in a wide range of light environments It features cutting edge H 264 real time video compression with excellent image clarity 720p for GXV3674 HD VF 1080p for GXV3674_FHD_VF and color fidelity industry leading SIP VoIP for video streaming to smartphones and video phones integrated PoE IR CUT mechanical for day or night mod and advanced security protection using strong encryption The GXV3674 HD FHD VF v2 can be managed with GSurf Pro Grandstream s intuitive FREE video management software that controls up to 72 cameras simultaneously or grouped with GVR3550 Grandstream Network Video Recorder NVR via plug n play as well as other ONVIF compliant video management systems It also offers an advanced and
51. ons with Auto 1 30 slowest 1 60 1 125 1 250 1 500 1 1000 1 2000 1 5000 and 1 10000 fastest e IR LED Setting Auto or manually turn ON or turn OFF the LED light Default Auto Manually On Off LED light applied to save power if camera powered by battery e IR CUT Setting Manual Automatic IR Sensor control or Time Schedule Mode configurable Daytime Schedule for user s flexibility to switch the mechanical IR_CUT e IR CUT Sensitivity Sensitivity of IR Sensor to trigger the IR CUT 5 levels total and 5 highest sensitivity e Color Mode Camera Color Mode There are three options Color Black White Auto Default e WDR Digital WDR or eWDR On Off switch default is Off FHD Models Only Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 29 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 andstream Innovative IP Voice amp Video NOTE gt Auto option recommended for Shutter Speed IR CUT Setting and Color Mode gt WDR feature has to be used where appropriate It has been developed specifically for scenarios with simultaneously light and dark areas in the field or vision not for solely low light scenes or bright light scenes gt You should first consider where and what you want to monitor and to what level of detail and consider the lighting conditions present because this will effect where you should place the camera for the best results gt Ifthe camera also needs to operate at night it may
52. org 10020 snapshot Mewd jpg Port Mapped via Router 1 Required Fields 2 Valid DNS server is required for hostname Save Test Figure 19 1 SMTP Setting Page e Enable SMTP When checked email client is enabled e SMTP Server SMTP Email Server IP or Domain Name e SMTP Server Port Port number used by server to send email e From Email address The email address of alarm email sending from usually client email ID e To E Mail address The email address to receive the alarmed email total 3 included e User Name Email client User ID e Password Email client password e SSL Check if the SMTP email server requires SSL e Email Subject Customizable email subject for user convenience e Email Content Customizable email body for user convenience Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 41 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video Enable SMTP k SMTP Server smtp gmail com SMTP Server Port 465 User Management Figure 19 2 SMTP Setting Page NOTE gt Click Save to save the email configuration information gt Click Test after configuration if setting is correct a test email will send out and Test successful orange bar will display like below Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 42 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 dstream Innovative IP Voice amp Video FT
53. p d p p P p f p P p dn P p P n P p P p P n P or P pr P or d p P p P g P r Por Por Por P or N y Lg BP pr Po n B r P g B pr B g BP pr Pg Pg Pu gg gor gg gp gp gg gc gg gc N n gp Pg n N p B P Date Start Time End Time Check All Everyday 00 00 23 59 Everyday 00 00 23 59 LI Everyday M 00 00 23 59 Add Delete Gancel Figure 24 3 Motion Detection Schedule Configuration Page e As shown in Figure 15 2 user can configure the Motion Detection Region with related Start and Stop time to control the motion detection operation NOTE User has to configure the Time Schedule otherwise the Motion Detection Alarm will not work if there is no time schedule configured gt Grandstream free GSurf_Pro VMS software can be downloaded from http www grandstream com products tools surveillance gsurf_pro zip Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 49 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 clean Innovative IP Voice amp Video Remote Alarm_Out peering with GXV3500 Decoder The GXV3672 series IP camera does not have built in Alarm In interface but when peering with Grandstream GXV3500 encoder decoder the GXV3500 s built in Alarm Out interface running at decoder mode can behave as remote Alarm Out of GXV3672 series IP Camera The benefit of such peering is the Alarm_Out circuit is not physically wired into the IP Camera anymore with the Ethernet network behaving as wiring the Alarm_O
54. pdated 02 2015 stream Innovative IP Voice amp Video ADVANCED SETTINGS EXPLANATION User Management Page This page allows user to do user management GXV3674 FHD VE Administration interface Manage User Existing User Name Add New User User Name User Management User Password Add Maintenance Confirm User Password Update SMIP EIE Privilege Administrator Delete Privacy Masks Administrator g B Manage Anonymous Viewing Alarm Server Allow Anonymous Viewing lw Time Lapse Photography Motion Detection Syslog Figure 17 User Management Page e Existing User Name Allow revise existing user or add new user e User Name The name of user need to be revised e User Password New password if revise password e Confirm User Password Re enter the new password for verification e Privilege Choose user privilege e Allow Anonymous Viewing When checked no security enhanced Any person can view the camera if knowing the IP or FQDN of the camera but can NOT change anything just view ONLY Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 37 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video Maintenance Page This page allows user to maintain the camera User Management Maintenance SMTP FIP Privacy Masks Alarm Server Time Lapse Photography Motion Detection Syslog Restart the Device Restart the Devic
55. r Night Mode 3 LENS Adjustable Vari focal Lens 4 IR CUT Sensor IR Cut Photonic Sensor 5 Far Near Adjustment Far Near Zoom Out In Adjustment screw 6 Focus Adjustment Focus Adjustment screw NOTE gt For accuracy please use screwdriver to adjust the Far Near and Focus screws Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 11 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 andstream Innovative IP Voice amp Video GXV3674 HD FHD VF v2 Specifications Modelv2 GXV3674 HD VF GXV3674 FHD VF 1 3 1 2 Megapixel Progressive 1 8 3 1 Megapixel Progressive T Day Night mode exceptionally low noise amp low light sensitivity 90 28 Horizontal Field Minimum Illumination 0 05 Lux O lux wit hIR O 1280x960 25fps 2048x1536 15fps Resolution and Frame Rate 1280x720 30fps 1920x1080 30fps Motion Detection up to 16 target areas Pre post alarm Recording Yes 8MB Yes 3MB Snapshots J Triggered upon events send via email F TP TCP UDP IP RTP RTCP HISP DHCP DDNS HTTP HTTPS Network Protocol SMTP FTP NTP Time Lapse Photography Yes Privacy Mask Support Power over Ethernet PoE IEEE 802 3af Class 0 SIP VoIP Support Yes S O Network RJ45 10M 100M auto sensing 3 5mm Line In External Cable Connection 3 5mm Line Out Power Input Dimensions L x W x H 255mm L x 104mm W x 187mm H Weight 1 10kg Operating 20 C 50 C 4 F 122 F 1
56. tic disconnecting the call Default 300 e Disable Audio in SIP Call Disable or turn off audio of camera when SIP call established e Enable Keep Alive Checked to help NAT resolution sending alive packets e Accept Direct IP Call Check to accept peer to peer IP call in LAN w o SIP server e Enable White List Number Filter Check to allow only white list number to call in for security e Enable two way Audio Warning Check to enable two way audio when call established Default e SIP Proxy Compatibility Mode Check to enable more proxy compatibility with cost of bandwidth the SIP call will send both audio and video no matter what e SIP Transport SIP transport protocol UDP as default e SIP TLS Certificate Copy Paste the TLS certificate here for encryption e SIP TLS Private Key Input private key here for TLS security protection e SIP TLS Private Key Password The password for SIP TLS private Key e Self define Warning Audio Upload self defined alarm warning message audio Format G 711 WAN format File Size lt 300KB Linear PCM 8KHz Sampling Rate 16bit Single Channel Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 34 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 stream Innovative IP Voice 4 Video Phone List for Alarm Out Phone Number Remark Name 6179114110 Local Police White List Allowed Caller Phone Number 6175669300 Figure 15 3 SIP Setting Page e Phone List for Alarm
57. tpd apache org or use Microsoft IIS web server Configuration File Download Grandstream SIP Device can be configured via Web Interface as well as via Configuration File through TFTP or HTTP HTTPS Config Server Path is the TFTP or HTTP HTTPS server path for configuration file It needs to be set to a valid URL either in FQDN or IP address format The Config Server Path can be same or different from the Firmware Server Path A configuration parameter is associated with each particular field in the web configuration page A parameter consists of a Capital letter P and 1 to 3 Could be extended to 4 in the future digit numeric numbers i e P2 is associated with Admin Password in the ADVANCED SETTINGS page For a detailed parameter list please refer to the corresponding firmware release configuration template When Grandstream Device boots up or reboots it will issue request for configuration file named cfgxxxxxxxxxxxx xml where XXXXXXXXXXXX IS the MAC address of the device i e cfg000b820102ab xml The configuration file name should be in lower cases Currently GXV3674_HD FHD_VF v2 only support XML configuration Grandstream Networks Inc GXV3674 HD FHD VF v2 User Manual Page 55 of 59 Firmware Version 1 0 3 5 Last Updated 02 2015 CC nn Innovative IP Voice amp Video RESTORE FACTORY DEFAULT SETTING WARNING Restoring the Factory Default Setting will DELETE all configuration information o
58. ttings Primary Stream Settings Preferred Video Codec H264 vi Profile Main Profile vi Resolution 192071080 16 9 vi CMOS Settings Bit Rate 4096 M kbps Networking DDNS Maximum Frame Rate 30 M fps Bit Rate Control Ge CBR VBR Hrame Interval 80 Frame 1 100 Secondary Stream Settings Preferred Video Codec H264 M Profile Baseline M Resolution 640 480 4 3 vi Bit Rate 512 kbps Maximum Frame Rate 15 fps Bit Rate Control Ge CBR VBR Hrame Interval 80 Frame 1 100 Figure 10 1 Video amp Audio Settings Page Video Settings e Primary Stream Settings o Preferred Video Codec MJPEG and H 264 supported H 264 recommended o Profile H 264 profile selection Default is Main Profile o Resolution The resolution in pixels used at video image o Bit Rate video bit rate or bandwidth used o Maximum Frame Rate Maximum frame rate used more data if big frame used o Bit Rate Control Constantly bit rate or variable bit rate o Image Quality Image quality used when Variable Bit Rate used o I frame Interval I frame interval suggested 2 3 times of frame rate Secondary Stream Settings Same as primary stream GXV3674 HD FHD VF v2 User Manual Firmware Version 1 0 3 5 Grandstream Networks Inc Page 26 of 59 Last Updated 02 2015 dstream Innovative IP Voice amp Video NOTE gt H 264 suggested if camera needs to be viewed via Internet gt The definition of Baseline Main Profile and High profile
59. ut circuit can now be located to convenient places where GX V3500 located This means IP Camera can be in location A while the Alarm Out can be in location B A and B can be in the same or different places as long as A and B can reach each other via network internet This will help a lot of users to monitor site remotely and take appropriate action because there are situations where location A with cameras but actions have to be taken from location B With Grandstream s solution traditional A and B limitation by the cable length is now disappear The configuration of such remote Alarm Out is very simple GX V3672 Side Same configuration as previous Motion Detection configuration just make sure Upload to Alarm Center checked and selected Alarm Action Record Video From Pre Alarm Upto 10 seconds to After Alarm Upto 30 7 seconds e Voice Alarm to SIP Phone w Upload to Alarm HTTP Server Oo Record Video and Upload to FIP Server xl Email and FTP upload JPEG Pre Alarm Upto 1 M seconds to After Alarm Upto 0 M seconds Save Time Schedule Config Figure 24 4 Remote Alarm Out IP Camera Configuration GXV3500 Decode Mode Side GX V3500 has to be running as Decode when functioning as remote Alarm Out of the peering IP Camera The configuration is as below 1 Input the 2 stream H 264 used as the RTSP URL with correct credentials as below 2 Only ONE stream currently decoding stream the Motio

Download Pdf Manuals

image

Related Search

Related Contents

IRiver T10 User's Manual  HMW90 and GMW90 Series Analog Output Models Quick  3750 ポータブルハイブリッドレコーダ用通信機能 /GP-IB, /RS-232C    KING - Securitex  Istruzioni per l`uso e il montaggio Piano di cottura in  Equipo portátil  Tripp Lite B060-032 KVM switch  Billing Guidelines (UB-04)  木製収納庫0.8帖タイプ 取扱説明書 3-1  

Copyright © All rights reserved.
Failed to retrieve file