Home

Notices about this User`s Manual

image

Contents

1. Endless Loop Programmed Endless Loop Recording Modes TR 51A 52 To find out more about settings and how to make them see the User s Manual that comes with the Communication Port TR 50C or with the Data Collector RTR 57C or the Help Menu in the Software Note In some cases recording will not start immediately and nothing will appear in the screen or the display will be jumbled This sometimes happens when the circuit board is touched during battery installation Remove the battery and install again following directions as in 2 Battery Installation The display may appear black if exposed to high temperatures This is not a malfunction and the logger is recording The display may be difficult to read if exposed to low temperatures This is not a malfunction and the logger is recording To change the recording settings see the User s Manual that comes with the Communication Port TR 50C or with the Data Collector RTR 57C The following settings can be made via computer communication TR 51A Select from 1 2 5 10 15 20 30 60 minutes pre iarsma omman s OOOO TR 52 Select from 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes Po Default Setting 10 minutes Immediate One time Recording starts immediately upon battery Recording Intervals Recording Methods installation When the unit reaches 16 000 readings the LCD alternately displays the current reading and FULL and recording stops Progra
2. is not necessary in the case of using CR2 Make sure not to touch the circuit board 3 Confirm that the rubber packing does not have dust or defects Dust or defects on the packing can adversely affect the waterproof characteristics 4 Close the case and close the cover Make sure the cover is closed in the correct direction 5 Changing the Battery 1 When battery power becomes low the battery indicator BAT will appear in the LCD display 2 Make sure to download all data before the battery loses all power 3 Replace with a new battery following directions as in 2 Battery Installation Caution After removing the old battery all recorded data will be lost if a new battery is not inserted within 1 minute Make sure to complete the battery change within 1 minute Lithium Batteries CR 2 can be used for this unit without the tube as shown above however the possible temperature measurement will be 20 to 60 C If you are measuring in an environment below 20 C or above 60 C we recommend the Optional Battery Set TR OOP2 All data such as recorded data and recording interval settings will be lost during battery replacement If the warning is displayed replace with a new battery as soon as possible Communication frequency 4 times month ee e e oa ose A about 1 year and about 2 years or Battery Life about 6 months about 1 year 6 months more TR 52 1 Remove screws
3. to 80 C 60 to 155 C Typ 40 3 C 20 to 80 C Typ 40 5 C 40 to 20 C 80 to 110 C Typ 1 0 C 60 to 40 C 110 to 155 C Measurement Accuracy Typ 0 5 C Measurement Display Resolution oe Recording Capacity 16 000 data Select from 1 2 5 10 15 20 and 30 seconds Select from 1 2 5 10 15 20 30 and 60 minutes or from 1 2 5 10 15 20 30 and 60 minutes Endless Overwrite oldest data when capacity is full One time Stop reading when capacity is full Recording Interval Recording Mode Temperature measured recording conditions battery life warning memory FULL sensor unconnected over measurement range and temperature unit F C Lithium battery ER3V M x 1 Measurement range from 40 to 80 C LCD Display Items power Available for lithium battery CR2 Measurement range from 20 to 60 C Battery Life Maximum 2 years depending on measurement environment and quality of battery Waterproof Capacity IP67 IP64 External Dimensions H62 x W47 x D19mm excluding protrusions Weight Approx 53g including battery Approx 55g including battery Unit Temp Resistance 40 to 80 C Lithium Battery ER3V Mx1 Tube x 1 Strap x 1 Accessories Included User s Manual Warranty x 1 Specifications for TR 5106 Standard Sensor TR 5106 x 1 70 to 180 C Diameter 2mm Cable length 0 6m Sensor Heat Durability Dimensions Thermal hour Constant Shielding Waterproof Capacity Approx 15 second
4. FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning This equipment has been verified to comply with the li
5. and open the case 2 Insert the attached battery into the tube and mount the tube in the direction shown in the figure Tube is not necessary in the case of using CR2 Do not touch the PCB 3 Confirm that the rubber packing does not have dust or defects Dust or defects on the packing can adversely affect the waterproof characteristics 4 Close the case and close the cover Make sure the cover is closed in the correct direction I 4 5 Connect the Sensor Make sure to fully push in the sensor to ensure good contact 6 Communication Setting Up for Communication If you wish to make Recording Start settings or Download already recorded data please follow the directions as written below 1 Place the Thermo Recorder TR 51A TR 52 face down on the Communication Port TR 50C sold separately or on the Data Collector RTR 57C sold seperately mCommunication Port mData Collector Note For details about making settings see the User s Manual that comes with the Communication Port TR 50C or with the Data Collector RTR 57C or the Help Menu in the Software 3 About Recording Data Temperature is immediately measured when a battery is installed Initial Setting Values Recording Interval 10 minutes Recording Mode Endless loop Recording Intervals TR 51A 1 2 5 10 15 20 30 60 minutes TR 52 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes Immediate One time Programmed One time Immediate
6. enotes an action that you must take Inside or near the symbol will appear another symbol giving details ES A D ANGER Do not take apart repair or modify the main unit It may cause fire electrocution or damage Ask the shop where you purchased the products or T amp D Corporation to carry out any repairs If any smoke or strange smells are emitted from the unit immediately cease using it Continued use may cause fire electrocution or damage Do not use any batteries other than those that are recommended It may cause fire or damage gt gt using it Q If water or a foreign object enters the case immediately cease Store all batteries sensors and Thermo Recorder units out of the reach of children Itis dangerous to swallow batteries Please be careful when using in overly hot or cold AA environments touching the units may cause burns or frostbite SS A CAUTO DEE We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the malfunction of our unit Please be fully aware of this before using our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly Do not drop or expose the unit to strong impact A sudden change in widely different temperature environments may cause condensati
7. mits for a Class A personal digital device pursuant to Subpart B of Part 15 of FCC Rules Only peripherals computer input output devices terminals printers etc certified or verified to comply with the Class A or B limits may be attached to this equipment Operation with non certified or non verified personal computer and or peripherals is likely to result in interference to radio and TV reception The connection of a non shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment You are cautioned that changes or modifications not expressly approved by party responsible for compliance could void your authority to operate the equipment GNIRY a Thermo Recorder TR 51A TR 52 Compact Waterproof Data Logger User s Manual Thank you for purchasing this product Carefully read and fully understand these instructions before using this unit T amp D CORPORATION 5652 169 Sasaga Matsumoto City NAGANO 399 0033 JAPAN Tel 81 263 27 2131 Fax 81 263 26 4281 Homepage http www tandd jp E mail overseas tandd co jp Copyright 1998 2004 T amp D Corporation All rights reserved 2004 09 16004034040 Product Specifications TR 51A TR 52 1 channel 1 channel Measurement Channels Sensor built in the main unit External sensor type Measurement Item Temperature Measurement Range 40
8. mmed One time Recording starts at the programmed date and time When the unit reaches 16 000 readings the LCD alternately displays the current reading and FULL and recording stops Immediate Endless Loop Recording starts immediately upon battery installation When the unit reaches 16 000 readings the oldest data is overwritten and recording continues Programmed Endless Loop Recording starts at the programmed date and time e When the unit reaches 16 000 readings the oldest data is overwritten and recording continues Unit of Temperature on F C Initial setting value C pew a In addition to communication the software is designed to help with data processing Computer Display and Printing Display downloaded data in graphs or tables and print out Saving Downloaded Data Create Files to save downloaded data into Create data into Text File for exporting to spreadsheets For details about all operations see the User s Manual that comes with the Communication Port TR 50C or with the Data Collector RTR 57C or the Help Menu in the Software
9. nd WindowsNT are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Company names and product names are trademarks or registered trademarks of each company e Please carefully read this User s Manual and Free Repair Warranty e The warranty that is included in this User s Manual cannot be reissued so please keep it in a safe place e The User s Manual for this and all T amp D products can be downloaded free of charge from our Web Site Safety Precautions and Instructions Please carefully observe the following safety measures when using our product To prevent any loss or damage to our customers other people and or property and to ensure the proper use of our products we ask that before using our product you carefully read understand and follow the safety rules and precautions for our products as outlined below Explanation of Warning Symbols These entries are actions that absolutely under no circumstance should be taken The taking of such an action may cause serious personal physical damage or death These entries are actions that if taken may lead to physical injury or damage to persons or things Explanation of Picture Symbols This symbol denotes an important warning or caution Inside or near the symbol will appear another symbol giving details This symbol denotes a forbidden action Inside or near the symbol will appear another symbol giving details This symbol d
10. on to occur Please use the unit in areas with a temperature range of 0 to 50 C and a humidity range of 10 to 90 RH with no condensation Do not put your fingers or foreign matter into the sensor connection Battery terminals may provide insufficient contact due to age or vibration Please be careful not to lose data due to insufficient contact Battery life depends on the measurement environment communication frequency recording interval and battery quality Seq oP gt gt A Pay attention as water leakage or foreign objects entering into the unit case is possible in the following cases The case was closed with dust hair etc on the rubber packing or in the groove for the packing The rubber packing becomes damaged In this case please purchase the optional maintenance set The unit suffered from significant temperature change while wet Especially in the case that the temperature changes from high to low Operate the units with the latest version of T amp D Recorder for Windows E The latest version software can be downloaded from our home page period of time Batteries left in a unit not being used for a long time may leak and cause a malfunction Do not use or store the unit in places such as listed below It may cause electrocution fire or damage to the unit or to your computer Areas exposed to direct sunlight Areas exposed in water or high pressure water flow Areas exp
11. osed to organic solvents and corrosive gas Areas exposed to strong magnetic fields Areas exposed to static electricity Areas exposed to fire or overheating Areas exposed to excessive dust or smoke Q Remove batteries from any unit that will not be used for a long This is printed on 100 recycled paper 1 TR 51A 52 Overview Our TR 51A and TR 52 Thermo Recorders are compact water resistant one channel temperature data loggers They can be used in both normal outdoor conditions and in harsh environments such as underground in snow and frozen conditions as well as in environments where temperatures vary greatly Use our Communication Port TR 50C or our Data Collector RTR 57C to transmit settings to the data logger and download data to computer for processing We have removed all switches from the main unit to assure nothing gets accidentally pushed during use thus assuring you of no mistakes no tampering and no loss of data With one unit you can record up to 16 000 readings If set at a one hour recording interval that gives you 666 days or almost two years of readings We offer two types to fit your needs the TR 51A with internal sensor with water resistant rating of IP 67 for temporary immersion and the TR 52 outfitted with external sensor with splash resistant proof rating of IP 64 The latest version of our software for TR 51A 52 can be downloaded free of charge from our Homepage Please visit us at h
12. s in the air Approx 2 seconds in agitated water Teflon resin IP67 Sensor Cable Notices about this User s Manual e Please read this manual carefully before using the product e All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation e Please follow the safety precautions carefully We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended e T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair of the attached warranty e T amp D Corporation accepts no responsibility for any result or effects from using this User s Manual e Figures and illustrations in this manual may be slightly simplified and may differ from the actual product e On screen messages figures or illustrations in this manual may vary slightly or be simplified from the actual messages and product e We sincerely hope that the contents of this manual are true and complete If you find any information to have been omitted or if the information within is confusing or mistaken please contact your retailer or T amp D Corporation e Microsoft Windows a
13. ttp Awww tandd co jp english for more information eTR 51A meTR 52 LCD Display Optical Commication Connector 4 LCD Display When being used in cold environments the display may become difficult to read This is not a malfunction Recording Status REC LIT UP displayed during recording or when FULL of data BLINKING displayed when waiting for a programmed recording to start Low Battery Life Warning Indicator BAT displayed when time to change the battery Measurement Reading and Message Display Unit of Measurement displays unit of measurement No Sensor Connected REC Cc Displayed when a sensor has not been connected has been disconnected or the wire has been broken Measurement and recording will continue and battery power consumed Over measurement range TR 52 c Temperature display blinks when the Cr Da rm temperature goes below 60 C or mm gt a a above 155 C h h WLI Full Memory coi hhk When using the One time Recording Method the REC mark appears when the number of recorded readings reaches 16 000 and the unit stops recording Estimates of time until FULL is displayed bout about 4 hours about 5 days about 11 days about 111 day 1 year aa moths 2 Battery Installation TR 51A 1 Remove screws and open the case 2 Insert the attached battery into the tube and mount the tube in the direction shown in the figure Tube