Home

USER MANUAL NTW-HD1616 Network Routing Switcher - AV-iQ

image

Contents

1. 8x8 Serial Digital Video 2 layer 5x5 Serial Digital Video 3 layer x 4x4 Serial Digital Video 4 layer Default mode is 16x16 Serial Digital Video 1 layer Serial Digital Video 1 layer SDV Signal Input SDV Signal Output 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 3 gt 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 11 11 11 11 12 12 12 12 13 13 13 13 14 14 14 14 15 15 15 15 16 16 16 16 Serial Digital Video 2 layer SDV layer 1 Input SDV layer 1 Output 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 Technical specifications are subject to be changed without notice CENA Routing Switcher Series Miran an Revision 2 10 6 6 6 6 7 7 7 7 8 8 8 8 SDV layer 2 Input SDV layer 2 Output 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 5 13 5 13 6 14 6 14 7 15 7 15 8 16 8 16 Technical specifications are subject to be changed without notice CENA Routing Switcher Series CL agag Revision 2 11 Serial Digital Video 3 layer SDV layer 1 Input SDV layer 1 Output 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 SDV layer 2 Input SDV layer 2 Output 1 6 1 6 2 7 2 7 3 8 s 8 4 9 4 9 5 10 5 10 SDV layer 3 Input SDV layer 3 Output 1 11 1 11 2 12 2 12 3 13 3 13 4 14 4 14 5 15 5 15 Technical specifications are subject to be changed without notice CENA Routing Switcher Series CL agag Revision 2 12 Serial Digital Video 4 layer SDV layer 1 Input SDV layer 1 Output 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 SDV layer 2 I
2. vvv vyvv is the input which shall be connected to the chosen output vvv vvvv input number 7 5 3 Crosspoint status request This command is used for status request on Audio and Video routers 1100nnnn OxxXXXXX nnnn is the matrix address from 0 up to 15 XXXXxxx do not carry any information The requested router Audio or Video will send its crosspoint status on MIDI OUT and RS232 The same command format as for crosspoint set is used Technical specifications are subject to be changed without notice CENA Routing Switcher Series CL agag Revision 2 17 General Environmental Requirements for Network Electronics Equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions e Operating room temperature range 0 C to 45 C Except of digital video routers 0 C to 40 C e Operating relative humidity range up to 90 non condensing 2 The equipment will operate without damage under the following environmental conditions e Temperature range 10 C to 55 C e Relative humidity range up to 95 non condensing 3 Electromagnetic compatibility conditions e Emissions EN 55103 1 Directive 89 336 EEC e Immunity EN 55103 2 Directive 89 336 EEC e Electrical safety EN 60 950 With reference to the declaration of conformity provided with the external power supply Technical specifications are subject to be changed without notice CENA Routing Switcher Ser
3. combination of routers working married counts as one address This might for example be 1 audio router 1 video router working as an audio follow video system or 3 video routers working as a RGB YUV system The routers in such a constellation have to have the same address 4 2 Connecting control panels To get a control panel working with a specific router give the control panel the same address as the router Several panels can be addressed to the same router The X Y panels can control 2 layers with breakaway function If it is necessary to control more layers with breakaway an additional panel must be used Panels can also be connected to a router via the RS 232 interface Please refer to your control panel manual for installation Technical specifications are subject to be changed without notice CENA Routing Switcher Series LL gt Revision 2 7 4 3 Pin out and cable type The pin out of all Network MIDI ports follows the standard MIDI specification A 1 to 1 cable with Spin DIN connector is used The following pin out is used 1 n c l n c 2 shield H 44 44 4 4444 4 44 2 shield 3 n c 3 n c 4 data 4 data data lines must 5 data 5 data be twisted pair The standard MIDI specification recommends the use of shielded twisted pair cable types for interconnection between the units Alternatively the MIDI can be connected to the RJ 45 connector The fol
4. 5V 13 pe 15 16 os coe oes oe C TALS O 45 conn n m 2 Power connection Do not connect mains to the desk top power supply before connecting the power supply to the router Connect the DB9 female connector from the desktop power supply to the main unit Tighten the screws to assure a proper contact To connect mains to the desk top power supply you need a mains cord with IEC 320 connector NTW HD1616 uses the desk top power model AC 10 87 30 005 45V 30W If an external power supply is used the NTW HD1616 router requires 5V DC with a minimum current of 4A The following pin out is used on the DB9 male power connector Pin 1 and 9 OV Pin 2 and 5 5V 3 Connecting the NTW HD1616 to your PC For connection to a PC with Miranda s i Control control software the RS 232 interface is used The RS 232 port on all Network devices uses the standard DCE pin out see pin out table under 4 3 A standard modem cable can be used for connecting the router to the PCs serial port 3 1 Selection of router address The router address depends on the system configuration the router is going to work with See chapter 5 for more information All routers are delivered with default address 0 A router addressed to 0 can be controlled from the i Control software with address 0 i Control offers the control of up to 16 different routers or combinations of routers Technical specifications are subject to be changed without notice CENA Routing Switcher S
5. Revision 2 1 USER MANUAL NTW HD1616 Network Routing Switcher Series HIGH DEFINITION SERIAL ROUTER 16x16 Miranda Technologies inc 2323 Halpern St Laurent Quebec Canada H4S 1S3 Tel 514 333 1772 Fax 514 333 9828 Miranda USA 1101 N Pacific Ave suite 204 Glendale CA 91202 USA Tel 305 820 2990 Fax 305 820 2991 e mail techsupp miranda com Technical specifications are subject to be changed without notice CENA Routing Switcher Series CL agag Revision 2 2 Index 0 Revision history 3 1 General 4 1 1 Specifications 4 1 2 Connection drawing 5 2 Power connection 5 3 Connecting the NTW HD1616 to your PC 5 3 1 Selection of router address 5 3 2 Pin out of RS 232 connector 6 3 33 Maximum cable length 6 4 MIDI connection 6 4 1 Several routers in one system 6 4 2 Connecting control panels 6 4 3 Pin out and cable type 7 4 4 MIDI bus structure 7 4 5 Maximum distance between MIDI devices 7 5 Router configuration 8 5 1 Router address 8 5 2 Router mode 9 5 3 Vertical interval trigger 12 5 4 Power up mode 13 6 Connecting video signals to the NTW HD1616 13 7 Control and connection of Network systems interface protocol 14 7 1 Important notes regarding the Network Control Protocol 14 7 1 1 Binary Code 14 7 1 2 Acknowledge Echo 14 7 1 3 RS 422 Matrixes 14 7 1 4 Timeout 14 T2 Basic principles 14 T2 i Example A single unit with no MIDI connected 15 T22 Example Several units conne
6. able to generate hexadecimal characters ASCII characters will not be accepted 7 1 2 Acknowledge Echo A matrix will reply on a crosspoint set command with an ECHO In the case where a crosspoint is already set no ECHO will be sent If the matrix is part of a MIDI system two types of reply will be sent Immediately after receiving the crosspoint set command the ECHO will be sent The matrix will then wait for the command to pass the MIDI bus system After receiving the command from the MIDI bus system the matrix will send the command as an ACKNOWLEDGE 7 1 3 RS 422 Matrixes RS 422 Data Routers do not accept distribution of an input signal to several outputs An input signal can only be routed to one single output The Firmware of our RS 422 routers takes care of these limitations If an input Source is already connected to a particular output Destination any connection of this input to another output will disconnect the previous connection The router will in this case send the following message for the disconnected output Output connected to input 128 Input 128 is an internal default for the disconnect status Please see Network recommendations for use of RS 422 data routers for further information 7 1 4 Timeout The Crosspoint Status Request message has a timeout which means that you need to wait 1 second in between request messages 7 2 Basic principles Any message on any level address which conforms to the standard arriving at
7. cted by MIDI 15 73 RS232 15 7 4 MIDI 15 73 Commands 15 TSN Audio crosspoint set 15 7 5 2 Video crosspoint set 16 7 5 3 Crosspoint status request 16 General Environmental Requirements for Network Electronics Equipment Error Bookmark not defined Technical specifications are subject to be changed without notice CENA Routing Switcher Series Miran an Revision 2 0 Revision history Current revision of this document is the uppermost in the table below Revision Replaces Date Change Description 2 1 09 02 01 Corrected baudrate settings 1 0 11 12 00 Changed User settings DIP switches 0 10 10 00 Initial Revision Technical specifications are subject to be changed without notice CENA Routing Switcher Series E gt Revision 2 1 General The NTW HD1616 is a 16x16 high definition serial digital video router with universal wideband technology to allow simultaneous switching of digital video signals from 143Mbit s up to 1 5Gbit s NTW HD1616 has automatic cable equalizing on all inputs and re clocking with automatic standard selection on all outputs Vertical interval switching is provided on a video reference input with PAL NTSC color black The NTW HD1616 is well suited for all demanding routing tasks in digital studio and broadcast environments The built in RS 232 interface allows the user to control the router via the i Control PC software with many operational features The c
8. either the MIDI or the RS232 port will be re sent on both MIDI and RS232 The only exceptions are a A matrix which recognizes its address will not re transmit the message if the crosspoint is already set b A matrix which recognizes its address will not re transmit the message if the output number or input number exceeds its size c A unit matrix or panel will not re transmit a message arriving at the MIDI if it was re transmitted a short while ago typically 0 5 sec This is done by grabbing a message storing it for the timeout period and comparing it with new messages After the timeout period the unit will grab a new message for compare This is done to remove unwanted read unknown messages from the MIDI ring d A message arriving at the RS232 will always be re transmitted unless it is a matrix and one of the cases a or b is fulfilled Technical specifications are subject to be changed without notice GSW Routing Switcher Series QM i ran gag Revision 2 15 7 2 1 Example A single unit with no MIDI connected Messages sent to the RS232 of a single unit will be returned once no matter what address or input output number the message has unless it is a matrix which recognizes one of the conditions a or b above 7 2 2 Example Several units connected by MIDI Messages sent to the RS232 of a single unit will be returned once no matter what address or input output number the message has unless it is a matrix which recognizes o
9. eries CL Revision 2 6 3 2 Pin out of RS 232 connector The DB9 female connector for the RS 232 port has the following pin out Pin 2 Tx Pin 3 Rx Pin 5 GND 3 3 Maximum cable length The maximum cable length for an RS 232 connection is per definition 15m Longer distances can be installed depending on the environmental conditions of the installation site It is up to the installer user to secure a proper installation of the RS 232 connection 4 MIDI connection Via the MIDI bus system several routers and control panels can be interconnected The standard MIDI interface is used on all Network MIDI control ports For interconnection between the devices a standard MIDI cable with Spin DIN connector on both ends is used The Network MIDI bus system allows connection of up to 16 routers with different addresses on the same bus Routers which are defined to work married e g 2 routers as Audio follow Video or 3 routers as RGB YUV must be set on the same address Control panels dedicated to work with a specific router must have the same address as the router Several panels can work together with one specific router Up to 16 single routers or combinations of routers can be controlled from one i Control control screen The MIDI bus system and all RS 232 ports interchange the system status 4 1 Several routers in one system The Network MIDI bus system allows the interconnection of up to 16 routers with different addresses in one system A
10. ies CL
11. line 1 switching for the 30Hz and 29 97Hz frame rates of SMPTE 260M and SMPTE 274M May be used for line 1 switching for the 25Hz frame rate of SMPTE 274M and SMPTE 295M May be used for line 7 switching for the 30Hz and 29 97Hz frame rates of SMPTE 260M and SMPTE 274M May be used for line 7 switching for the 25Hz frame rate of SMPTE 274M 5 4 Power up mode Switch 8 on the configuration switch defines the power up mode The NTW HD1616 router provides two modes for powering up the system Mode 1 switches all outputs to input 1 Mode 2 switches all outputs according to the buffered information in the routers processor system The power up reset can be switched according to the following pattern means switch down 7 means switch up Switch 8 Power Up Reset Mode 2 Mode 1 Default is Mode 2 6 Connecting video signals to the NTW HD1616 The NTW HD1616 router offers standard 75 ohms BNC connectors for video in and outputs All video inputs are terminated with 75 ohms Technical specifications are subject to be changed without notice GSW Routing Switcher Series Le gag Revision 2 14 7 Control and connection of Network systems interface protocol 7 1 Important notes regarding the Network Control Protocol 7 1 1 Binary Code The strings shown on the next pages are in binary coded format Please be aware of the fact that any terminal program you may use to control a Network unit from a PC must be
12. lowing pin out is used Pin 1 nc Pin 2 nc Pin 3 nc Pin 4 MIDI Pin 5 MIDI 123 d Pin 6 nc Pin 7 nc Pin 8 nc 4 4 MIDI bus structure The Network MIDI bus structure follows the standard MIDI bus definition The Network MIDI bus is defined as a closed chain of units This means that the MIDI OUT of the last unit must be connected to the MIDI IN of the first unit in the MIDI chain To avoid problems with the control of Network units the installer user has to assure that the bus structure is installed according to this definition The total number of MIDI devices in a MIDI chain is limited to 50 4 5 Maximum distance between MIDI devices The standard MIDI definition allows a maximum cable length of 250 meters between two devices Longer distances can be made with MIDI repeater units To avoid grounding problems all Network MIDI ports have opto coupled inputs Technical specifications are subject to be changed without notice CENA Routing Switcher Series CL agag Revision 2 8 5 Router configuration The Dip Switch Block top right 2 user switches sets the communication channel operation The operation can be switched according to the following pattern means switch down means switch up Default setting is RS 232 operation on 9 pins DSUB Switch 1 2 Operation Not allowed RS 232 operation on 9 pin DSUB R RS 422 operation on RJ 45 Not allowed Note that ONLY 1 switch must be
13. ne of the conditions a or b above If none of the cases a or b is fulfilled the message will also be transmitted on the MIDI Then if any unit on the MIDI ring recognizes any of the cases a b or c the message will stop at that point This means that the message will only be returned once on the RS232 However if none of the units on the MIDI ring recognizes any of the cases a to c the message will return to the originator the unit which received the message on RS232 This unit will re transmit the message once more on both MIDI and RS232 The message is therefore returned a second time on RS232 This time one of the cases a or c is sure to be identified by one of the units on the MIDI ring and the message is removed There is however one more special case If several messages for unused addresses are transmitted with only little delay one might experience that some messages are returned several times as the store compare remove function in case c can only handle a single message at the time We therefore recommend that the user avoid sending messages to unused addresses 7 3 RS232 The RS 232 port is used for external control of Network units The RS 232 port allows the customer to control the equipment via Miranda s 1 Control PC program or self defined customized solutions Connector for the RS 232 port is a DS9 female Pin 2 Tx Pin 3 Rx Pin 5 GND A standard DCE Data Communication Equipment cable can be used for con
14. nection between PC and Network equipment The connection between the connectors is made one to one Data rate is 19200 baud sec 8 data bit 1 stop bit no parity 7 4 MIDI The MIDI bus is used for interconnection between several Network units Up to 50 routers and or control panels can be linked together to form a routing system with many operational features The MIDI bus utilises a 5 mA current loop with opto coupled ports Standard connector is a 5pin DIN Standard MIDI cables can be used to interconnect several Network units Data rate is 31 25 kbit sec 1 start bit 8 data bit no parity 1 stop bit Logical 0 current ON 7 5 Commands 7 5 1 Audio crosspoint set Only for use with Audio routers Command for setting of crosspoints 1001nnnn Okkk kkkk Ovvv vvvv nnnn is the matrix address from 0 up to 15 Technical specifications are subject to be changed without notice CENA Routing Switcher Series 0M i ran gag Revision 2 16 kkk kkkk is the output which shall be controlled kkk kkkk output number 0 output 1 127 output 128 vvv vyvv is the input which shall be connected to the chosen output vvv Vvvv input number 7 5 2 Video crosspoint set Only for use with Video routers Command for setting of crosspoints 1010nnnn Okkkkkkk Ovvvvvvv nnnn is the matrix address from 0 up to 15 kkk kkkk is the output which shall be controlled kkk kkkk output number 0 output 1 127 output 128
15. nput SDV layer 2 Output 1 5 1 5 2 6 2 6 3 7 3 8 4 8 4 8 SDV layer 3 Input SDV layer 3 Output 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 SDV layer 4 Input SDV layer 4 Output 1 13 1 13 2 14 2 14 3 15 3 15 4 16 4 16 5 3 Vertical interval trigger The NTW HD1616 router allows VIT switching for both SDTV and HDTV The NTW HD1616 accepts only standard analog black burst composite sync composite video signals in 525 30 525 29 97 or 625 25 format as the VIT reference In order for VIT switching of HDTV signal to work the HDTV signal must have both the same frame rate and Vertical sync timing Ov incident as the applied VIT reference Since the line duration is different for the HDTV signals and the VIT reference the actual switching time is timed from the Ov incident Switch 1 and 7 on the configuration switch set the VIT mode The modes can be switched according to the following pattern means switch down OFF means switch up ON Technical specifications are subject to be changed without notice CENAA Routing Switcher Series 0M i ran gag Revision 2 13 DIP SW pos 1 DIP SW pos 7 VIT 525 625 line Switch timing Don t care ON SDTV 525 30uS 5uS after Oh line 10 Don t care ON SDTV 30uS 5uS after Oh line 6 OFF line 1 OFF HDTV 10 15uS after Ov OFF line 1 OFF HDTV 12 17uS after Ov ON line 7 OFF HDTV 525 187 192uS after Ov ON line 7 OFF HDTV 625 225 230uS after Ov May be used for
16. ontrol bus technology allows linking the unit with the NTW A1616 or NTW AD1616 to create an AFV router One or several NTW 16 ProX Y remote control panels can control the NTW HD1616 as well Another unique feature of the Network 16x16 series is the possibility to reconfigure the router via the configuration switch on the back plane to create several formats of routers 16x16 Serial Digital Video 1 layer 8x8 Serial Digital Video 2 layer 5x5 Serial Digital Video 3 layer 4x4 Serial Digital Video 4 layer 1 1 Specifications Data rate 143Mbit s 1 5Gbit s VIT input Comp Video 1Vpp 300mV sync 75 ohms Number of inputs 16 terminated Equalisation Automatic up to 100m 1 5G Belden 1694A Number of outputs Re clocking Impedance Return loss Signal level Connector AC power DC power Dimensions 16 On outputs auto standard select 75 ohms gt 15dB SMHz 1 5GHz 800mV 410 BNC External power supply 100 260 VAC 5V connector DB9 male 483 x 88 x 35 mm 19 2RU Technical specifications are subject to be changed without notice CENA Routing Switcher Series Revision 2 5 Power conndctor MIDI bus 1 2 Connection drawing Vertical interval trigger Video output section Video input section RS 232 port O 1 2 3 4 O 6 6 od 8 7 6 S 4 3 e zk 6 7 8 Beet Rout Switch NBOS outing Switcher 9 10 11 12 16 15 14 13 12 ii 10 9 POWER 4
17. set at any time to ensure proper function 5 1 Router address The Dip Switch Block bottom right 8 user switches has the following switches Switch 2 4 on the configuration switch set the router s address for communication with the i Control and other units in the MIDI bus system The i Control control screen and the panels on the MIDI bus dedicated to operate with the router have to have the same address If several routers are combined to form an Audio Follow Video RGB or similar system these routers have to have the same address The addresses can be switched according to the following pattern means switch down means switch up Default address is 0 Switch 2 3 4 Address 0 z 7 1 z 2 2 2 3 4 x 2 x 5 x 6 7 Technical specifications are subject to be changed without notice CENA Routing Switcher Series 0M i ran agag Revision 2 5 2 Router mode The NTW HD1616 router allows switching in different modes You can choose among 16x16 Serial Digital Video 1 layer 8x8 Serial Digital Video 2 layer 5x5 Serial Digital Video 3 layer 4x4 Serial Digital Video 4 layer Switch 5 6 on the configuration switch set the router s mode The i Control software must be configured according to the mode chosen on the router The modes can be switched according to the following pattern means switch down i means switch up Switch 5 6 Mode 16x16 Serial Digital Video 1 layer

Download Pdf Manuals

image

Related Search

Related Contents

Mechanic`s Tips 3000 and 4000 Product Families Allison 4th  GpTmO NOO - 有限会社 石松測器  RUTINAS EN LISP - Universidad Politécnica de Valencia  VT-H1・H2・H3・M1・M2表    High End Systems Technobeam Work Light User Manual  StarTech.com 2m 10 Gb Aqua Multimode 50/125 Duplex LSZH Fiber Patch Cable LC - SC    Spec Sheet  取扱説明書  