1. eisen HUMIDITY AND TEMPERATURE CONTROLLER HT INSTALLATION MAINTENANCE AND USER MANUAL Elsteam S r l Ver 14 01 UK ToC T PACKAGE CONTENT uskadde 3 2 SECURITY MEASURES succ 3 1 1 GENERAL EN 3 1 2 THERMO HYGROMETRIC CONDITIONS OF THE INSTALLATION i 3 1 3 WASTEDISPOSALI nann enn e eea a daa ee ae 3 1 42 WARRANTS ie rana ae 3 MANUFACTURER cicala 4 4 4 CONFORMITY DECLARATION cune 5 5 WORKING PRINEIPEE sail 6 6 CHARACTERISTICS nii a O A A NA AAA AAA A A O 6 7 HT CONTROLLER BEHAVIOUR 7 8 HT CONTROLLER PROGRAM MING 7 9 ELECTRICAL CONNECTIONS eee 8 10 HT CONTROLLER BOARD COM PONENT SIDE rina 9 11 HUMIDITY TEM PERATURE PROBE CONNECTION LINPICCO A420 snnvnavsvnnnsnnenansenansennnsnnensnsensnsennnsenerseserannene 10 Please before using your equipment read this guide carefully by noting all the precautions and safety instructions reported in it Keep your equipment in good operative conditions Familiarize with the working and security instructions related to the operation of your apparatus before trying to make it function Keep this guide and any other booklet provided with your apparatus to be able to refer to them later 1 Package content HT controller packaging contains The controller The humidity and temperature probe LINPICCO A420 This us
2. direttive comunitarie e 2006 95 CEE Direttiva Bassa Tensione del Consiglio 27 Dicembre 2006 e 89 336 CEE Compatibilit Elettromagnetica EMC modificata da Direttiva 91 263 CEE del Consiglio del 29 aprile 1991 Direttiva 92 31 CEE del Consiglio del 28 aprile 1992 Direttiva 93 68 CEE del Consiglio del 22 luglio 1993 Direttiva 04 108 del Consiglio del 15 dicembre 2004 Claudio Cattaneo Dirigente Responsabile Funzione Claudio Cattaneo Dirigente fr Responsabile Funzione 2013 Anno 5 Working Principle Elsteam HT controller is a programmable humidity and temperature controller It has following operational modes e Hygrostat Thermostat default e Thermostat e Hygrostat Thermostat operational mode can be programmed for cooling or heating Humidistat mode can be programmed for humidifying or dehumidifying 6 Characteristics Technical characteristics 4 20mA humidity probe Input PT1000 temperature probe RS485 not available 1 ON OFF output 1 ON OFF output 1 ON OFF output 1 ON OFF output relay Temperature heating relay Temperature cooling relay Humidity humidifying relay Humidity dehumidifying Output 1 linear output 0 5V Temperature 1 linear output 0 5V Humidity 1 output Attivazione 5 12 1 ON OFF output relay Alarm Electrical Connections Power Supply 12Vac 12Vdc Power Mechanical Dimension
3. 13 11 Humidity Temperature probe connection LinPicco A420 Rear Side Connector Component Side LinPicco A420 Probe rear connections Connections A420 Controller W5 PT1000 Pin 10 W6 PT1000 Pin 11 W10 Current Loop Vcc Pin 3 W7 Current Loop Return Pin 9
4. er guide A single phase 230 Vac 0 12 Vac transformer option 2 Security measures 11 General Measures People who are not familiar with this type of equipment or who have not read this manual carefully should not be allowed to use the humidifier Your controller has been designed to be used with AC voltage 12V or 230 50 60Hz if the optional transformer is bought Do not attempt to use the humidifier with a different kind of power supply Check that the mains voltage corresponds to that of the controller Your controller must always be turned off before any maintenance All maintenance and repair work must be performed by the manufacturer its service agent or qualified service personnel 1 2 Thermo hygrometric conditions of the installation Make sure that the environmental conditions of the place where the humidifier is installed are compatible with the requirements of the product as specified in this manual Each product Elsteam cannot be installed exposed to the weather or freezing temperatures unless different terms are explicitly expressed in related document 1 3 Waste Disposal Directive 2002 96 EC of the European Parliament and the relevant national rules impose an obligation not to dispose of WEEE as unsorted municipal civil but to set up a special collection for obsolete parts of the humidifier It is still given the option to the buyer to return the humidifier into disuse at Elsteam Ltd in case o
5. f purchase of an equivalent humidifier Elsteam will dispose of them in their own or through its agents The disposal of electrical or electronic components in an abusive manner and not in accordance with applicable regulations is forbidden by the law In the event of illegal disposal of electrical and electronic waste the penalties are specified by local waste disposal legislation 1 4 Warranty Elsteam 5 acknowledges to its products guarantees of law applicable at the time of sale of the product and in any case guarantees at all times even ten years after the sale the free replacement of components which considers the apparent problem of construction Misuse and lack of maintenance will be automatic forfeiture of any form of guarantee 3 Manufacturer Manufacturer Elsteam S r l Sede legale amministrativa Via ENRICO FERMI 496 21042 CARONNO PERTUSELLA VA ITALY Contatti Tel 0039 029659890 Fax 0039 0296457007 Email infocomm elsteam com Web www elsteam com 4 4 Conformity Declaration IL COSTRUTTORE ELSTEAM S r l Azienda Via Enrico Fermi 496 21042 VA Indirizzo Cap Provincia Caronno Pertusella Italy Citta Stato DICHIARA CHE LA MACCHINA Umidificatore a resistenze REH Descrizione Modello REH 2013 Serie Matricola Anno costr Umidificatore Proporzionale ad Alta Pressione Denominazione commerciale Umidificazione di ambienti Uso previsto conforme alle
6. is relay is activated if the parameter does not reach the set point within parameter value time hours Last alarm display information concerning last occurred alarm e Alarm string string to display during alarm conditions ex assistance phone number e Time setting e Day setting 1 If the value passes the set point temperature or humidity by parameter value the linear output reach 100 5V 9 Electrical Connections Pin Description 1 Power Supply 2 Power Supply 12Vac 3 Output 12 Vcc 4 GND 5 RS485 A not used 6 RS485 B not used 7 Linear Output 0 5Vcc humidity 8 Linear Output 0 5Vcc temperature 9 GND current loop input 4 20mA humidity probe 10 PT1000 Input temperature probe 11 PT1000 Input temperature probe 12 ON OFF output V V can be set to 5Vcc or 12 at farm Default 12Vcc 13 Alarm Relay contact 14 Alarm Relay contact 15 Humidity Relay 1 contact humidification 16 Humidity Relay 1 contact humidification 17 Humidity Relay 2 contact dehumidification 18 Humidity Relay 2 contact dehumidification 19 Temperature Relay 1 contact heating 20 Temperature Relay 1 contact heating 21 Temperature Relay 2 contact cooling 22 Temperature Relay 2 contact cooling 10 HT controller board component side a 5 ut 95189035 ZIZINdH UYd x 9315
7. s mm LxPxA 6 5x6 5x16 cm Weight kg 7 controller behaviour The controller has two lines display and 4 keys keyboard e SET e OK e a un e 5 During normal operational mode press SET key to enter exit programming mode Buttons and are used to move between items in menu or increase decrease parameters value OK key is used to confirm parameter value By pressing or buttons while not modifying a menu parameter allows the user to change display data Date Temperature Humidity mm Set Point gt Time 8 HT controller programming Menu move between menu items use and buttons e Language o Italian default o English French e Working Mode Hygrostat Thermostat default o Thermostat Hygrostat e Thermostat working mode if thermostat mode selected o Heating default Cooling e Hygrostat working mode if hygrostat mode selected Humidifying default Dehumidifying e Temperature set point if thermostat mode selected e Humidity set point if hygrostat mode selected e Temperature hysteresis if thermostat mode selected default 1 C e Humidity hysteresis if hygrostat mode selected default 3 e Temperature threshold if thermostat mode selected default 15 e Humidity threshold if hygrostat mode selected default 15 e Alarm default OFF e Alarm Hours if alarm on default 1h o If alarm