1. will startup all the software components detector controller TCS and Lamps modules for detail see document ECH60S 2 X Software architecture The startup process consists of a series of xterm windows green for the application gray for panview the detector controller server showing the startup progress During this process the Main GUI will remain with a busy cursor once all is done the GUI will become active and the cursor will come to normal For details on the startup scripts please see document ECH60S 2 X on architecture and maintenance 1 3 Software Shutdown To shutdown the software there are four ways a GUI click on the red Exit button on the main GUI b icon click on the desktop icon called shutdown ECHELLE c type on any terminal or console shutdown_ECHELLE d type in any terminal or console shutdown_application ECHELLE In all cases a red xterm will appear showing the shutdown process Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 4 Chapter 2 Main GUI Reference When the application has started and it is ready the user is presented with a single window When the startup process started with no failures then the three LEDs on the upper right corner of the GUI should appear GREEN stating that the detector controller TCS connection and temperature controller are initialized and ready Figure 2 1 shows the main GUI and its LEDs Figure 2 1 Main GUI and LEDs Echelle User
2. X box size number of columns of region starting at X start Y box size number of rows of region starting at Y start Apply apply the specified ROI All the dimensions are in unbinned data pixels so if binning is selected the ROI is still specified as for binning 1 In the upper right corned there is a drop down menu called pre set geoms By selecting something there it will change the geometry ROI Binning speed etc to some pre set value This allows sped in changing between common geometries How to make a new geometry available for the drop down is described in document ECH60S 6 X panview configuration When release the software there where two available options full full frame 1x1 binning and 400_1600 full in cols 400 to 1600 in Y 1x1 binning Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 20 3 3 Plug Ins gt LAMPS This Plug In allow a direct and clear manipulation of the comparison lamps This allows the user a manual operation of the comparison lamps similar to the manual manipulation done through the actual physical switches on the console The logic of the lamps control is described in detail on document ECH60S 5 X on comparison lamps automation and also on document ECH60S 2 X on software architecture so here we will just describe its main aspects The actual control signal for the each lamps is an OR between the manual switch and the software command The mo
3. coude room temperature etc The upper part shows the temperature name then comes the actual temperature in Celsius degrees and finally an LED that remains green if the correspondent temperature is in reasonable ranges and that turns red when the temperature goes out of the allowed limits alarm Under this condition an actual text warning message is displayed I the async error dialog see 2 4 Figure 2 3 temperatures indicator Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 7 2 3 MAIN_GUI gt TCS read only This part shows the Telescope information as returned by the Telescope Control System TCS by itself Each field box name is self explanatory The information update rate is a parameter see document ECH60S 2 0 on administration but by default it is 3 seconds so the fields will be updated every 3 seconds Figure 2 4 TCS info indicators Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 8 2 4 MAIN_GUI gt ASYNC ERROR box read only An asynchronous message is something not related to any specific command request from the user as a alarm warning etc for example if the CCD temperature is too high etc An error is a condition caused by a direct user command for example if the image could not be written because there is no enough disk space This box displays both errors and asynchronous messages If the asynchronous message is an alarm it may also have another asso
4. gt shutter_close gt readout gt lamp off If this type is selected there will appear a drop down menu showing the available lamps and there the user can choose what lamp will be used for the calibration The lamp will be turned off automatically after the sequence so the the user does not need to worry about turning on off the lamp When this type is selected there will also appear a drop down menu to select the position of the IODINE cell IN or OUT Based on the selection the iodine cell will be moved IN or OUT of the light path at the moment of the selection ExpTime sec controls the length in seconds of the integration goes into the exptime key header Exp controls how many exposures to do using all the above settings Comments Any desired commentary This goes into the fits header as a standard fits COMMENT Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 12 Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 13 2 6 MAIN_GUI gt Exposure Control write This allows to start the actual exposure s and to control it once it is in progress Start once the exposure has been setup see 2 5 by clicking this button the exposure will start Pause allows to pause an exposure when it is on the integration phase To resume it press the same button again the label will change to resume Stop Stops an exposure once it is on the integration phase When stopped it will stop integrating and
5. normal state is TRUE so every image taken is written to disk Figure 2 6 b shows the exposure setup controls Object a ooo Figure 2 6 b exposure setup Observer Observer s name This information will appear on the observer fits key Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 11 Observation Tile Object This sets the object name This will appear as the key object in the image headers Observation Type This sets what kind of image will be taken This goes on the imagetyp key header The available image types are settable through the configuration file but the standard ones are Object Dark Bias regular object observation clear gt shutter_open gt integration gt shutter_close gt readout When this type is selected there will also appear a drop down menu to select the position of the IODINE cell IN or OUT Based on the selection the iodine cell will be moved IN or OUT of the light path at the moment of the selection dark image no light clear gt integration gt readout zero bias frame no integration clear gt readout If this type is selected the ExpTime control will not be present always 0 exposure time Flat Calibration calibration reference image using comparison lamps Regular observation as an object but the selected comparison lamps is turned on lamp on gt clear gt shutter_open gt integration
6. s Manual CTIO 60 inches Echelle ECH60S 1 3 5 2 1 MAIN_GUI gt Exposure Progress read only The exposure progress area shows information regarding the image status when an observation is in progress Exp Done upper yellow bar shows the sequence how many images has been done compared to the total amount of images requested Dark Time shows the total amount of dark time in the current exposure seconds Pause Time shows the total amount of time elapsed since pause in the current exposure seconds Exposure time lower yellow bar shows the total amount of exposure integration time elapsed seconds Done a Dark Time Pause Time ooo ooo ir 1 00 Exposure Time 0 00 Readout _ 100 Write Proc Controller State State IDLE Figure 2 2 Exposure progress Readout upper cyan bar shows the percentage of current image readout Write progress lower cyan bar shows the percentage of current image write Controller State shows the detector state IDLE EXPOSING READING Image State shows the image state IDLE WAITING WRITING DONE Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 6 2 2 MAIN_GUI gt Temperatures read only The temperatures information area shows the current temperature of different points of interest in the system Currently the only information corresponds to the detector CCD controller but in the future there will be some others added Echelle body
7. will be readout immediately The headers will show both the requested exposure and the actual exposure see Appendix A headers Abort Aborts an exposure readout This button will cause the exposure to finish immediately but the image will not be readout data will be lost Figure 2 7 Exposure control Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 14 2 7 MAIN_GUI gt Plugins write This area allows to access any Plug In that may be available A Plug In is a sub gui that allows to perform an specific task It is an expansion to the functions of the main gui New Plug Ins can be added at any time The Select PT drop down menu will show any available Plug In The buttons Display and Geometry call some generic and useful Plug Ins described next The currently available Plug Ins are described in th following chapter Select PI Figure 2 8 Plug Ins drop down Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 15 Chapter 3 Plug Ins Reference The Plug Ins are expansions to the main GUI functionality They are auxiliary guis that are specific to some specific tasks The advantage of using Plug Ins is that the main GUI does not get crowed with functionality that may not be used all the time it allows to keep the man GUI as simple as possible Also It makes very easy to add functionality afterwards without affecting the main GUI It provides modularity and the capability of natural e
8. 1 015 airmass CCD NECK Coude room and Echelle body temperatures in Celsius degrees CCDTEMP 120 ccd temperature NECKTEMP 165 dewar neck temperature TEMPAIRI 17 12 coude room temperature TEMECH 15 20 echelle body temperature Comparison lamp status States what lamp was in use none if no lamps was ON COMPLAMP QUARTZ comparison lamp Iodine cell position in the light path IN or OUT IODCELL OUT iodine cell position Requested exposure time This value usually is the same as exptime however it may differ is the image was stopped during integration In that case exptime will show the actual effective integration while this filed will show the originally requested exposure time REXPTIME 12 requested exposure time Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 26 Dark current time This shows how long the detector was acquiring dark current This is usually the same as exptime but it may differ is the exposition was paused resumed In this case exptime will show a smaller value than the dark time the detector was generating dark current all the time including the paused time DARKTIME 12 dark current time in secs This in engineering information that may be useful software firmware versions and hardware configuration slot and card name firmware version and electronic ID DHEINF MNSN fermi hardware controller info DHEFIRM home ob
9. Echelle GUI User s Manual CTIO 60 inches Echelle ECH60S 1 3 La Serena May 2010 Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 Contents Inroducetiolizora a ais eee el CIM eect Ae RA a 3 Chapter 1 Getting Things Running ssisscocescsacesaedeacvvacds RR RZ rata agi 4 li Hardware Sei Peel nana eens eeti sae eee cetera 4 1 2 Software SEU paria isla eo ea 4 lS SpfiwareShutdowhis oloni lillo idee ili al LUI 4 Chapter 2 Mam GUI Reference ARE RR IR 5 2 1 MAIN GUI gt Exposure Progress read only ices aaa 6 2 2 MAIN GUI gt Temperatures read Only ritirare 7 23 MAINLGUFSTES read ony yiee alii 8 2 4 MAIN_GUI gt ASYNC ERROR box read 0N1Y erne rense renerne ens r rr en nes 9 2 5 MAIN GUI gt Exposure Setup WI 10 2 6 MAIN GUI gt Exposure Control Write ariunlahialaa calata 14 2 PMAIN GUF gt PS Write diar raa ere so sted ones 15 Chapter 3 Plug Ins Reference cile 17 Sel Plus lt Ins S DISPLAY ell ar ae ra 18 3 2 Pl s ns gt GEOME TRY ro aen een 20 3o Pl s ns LAMPS reann allo 22 SA Plugins gt TODCEL ivsesecedcosaivsiccsveveseesitdesdessveashensvuneveyesuscsscaunaegneanivesaues aun deoveuond canes AA 24 Appendix A HeddeTi nhb ll lola ere en ele 25 Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 2 Introduction The following document is a reference to the CTIO 60 inches ECHELLE Software It provides a way of understanding both handling and capabilities The sof
10. area only The indicators right to the z1 and z2 controls indicates the current z1 z2 values either manual or the last automatic ones if autoscale is selected strip_overscan if this box is checked the display will strip the overscan after the image has been read Note that it does so for display purposes only the actual image is not touched This stripping is done Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 17 by invoking a python script autodisplay py that uses pyraf to re display the image The script s description can be found in document ECH60 2 X Software architecture Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 18 3 2 Plug Ins gt GEOMETRY This Plug In allow to change image geometry speed variables parameters that can make the image smaller or have a different aspect ratio etc OM 5 QL o Om iteiten Font chia al Geometry Figure 3 2 Geometry Plug In Readmodes Amplifiers select what amplifer to use upperboth use both upper right and upper left amplifiers Speed select the readout speed to use fast noisier or slow Binning x binning in columns y binning in rows Apply apply binning changes ROI Select region of interest sub window to read Enable enables the selected ROI Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 19 Disable go back to full frame mode X start starting column of interest Y start starting column of interest
11. ciated action like a beep Figure 2 5 async err box Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 9 2 5 MAIN_GUI gt Exposure Setup write This areas are for the exposure setup itself These fields are all settable by the user It allows to setup the exposure before it actually starts Figure 2 6 a shows the image setup information Path directory where the image will be written Seq Num initial image number It will increment automatically for every new image Basename base name for images These three variables define the image on disk as lt Path gt lt Basename gt lt Seq Num gt fits The number is set with 4 places and it is left filled with zeros so it always has 4 digits 04d Example if Basename is test and Path is data and Seq Num is 2 the next image will be data test0002 fits fer in basename 000 q ni Figure 2 6 a Image setup controls Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 10 The red bar shows the available space on the chosen file system the disk where the chosen directory is This is of course read only The check box Set type as basename if checked will make that every time the image type see below changes the base name changes accordingly for example if image type is Dark the image base name will switch to dark etc The check box write image enables or disables writing the image to disk The
12. ftware also provides a timer to set a maximum on time for the lamp This time is a configurable parameter but it is not available to the user from the GUI but as a configuration file to be edited manually see also ECH60S 2 X In general the user does not need to use this Plug In as the lamp will be automatically handled including the lamp selection when the observation type calibration is selected see 2 5 under observation types gt calibration Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 22 3 4 Plug ins gt IODCEL This Plug In allow a direct and clear manipulation of the iodine cell position This allows the user a manual operation of the comparison lamps The logic of the iodine cell operation is described in detail on document ECH60HF 7 X on RTD Data I O box description and also on document ECH60S 2 X on software architecture so here we will just describe its main aspects The actual control signal for the motor is an OR between the manual switch and the software command File Edit View Project Opera lejere HE cose manual switch control fiovine fi 50 Figure 3 4 Iodine cell Plug In The upper box manual switch show the status of the manual switch name of the switch on top LED shows on off condition The lower box show the iodine cell position The LED shows the status of the actual output control signal The switch in the box indicates the software swi
13. ich the shutter was open This is set internal and has an accuracy of 2 ms UTSHUT 2009 12 22T11 21 31 683 UT of shutter open Number and order of amplifiers in the y vertical and x horizontal directions Set automatically depending on the amplifiers in use selected on the readmodes drop down menu in the Geometry Plug In NAMPSYX 12 Num amps in y and x eg 2 2 quad AMPLIST 21 22 Readout order in y x Image geometry This are standard NOAO WCS keywords They describe the are of the image that corresponds to amplifier ASEC Bias BSEC CCD CSEC Data DSEC trim TSEC Besides that we have RSEC Roi or sub window section and AB AD amplifier bias and data which corresponds to Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 24 those sections inside the amplifier The suffix 21 or 22 corresponds to the physical amplifier 21 upper left 22 upper right 11 lower left 12 lower right ASEC21 1 1081 1 2048 amplifier section 21 UL detID 1 BSEC21 1032 1081 1 2048 bias section 21 UL detID 1 CSEC21 1 1031 1 2048 ccd section 21 UL detID 1 DSEC21 1 1031 1 2048 data section 21 UL detID 1 TSEC21 8 1031 1 2048 trim section 21 UL detID 1 RSEC21 1 1024 1 2048 roi section 21 UL detID 1 ABSEC21 1032 1081 1 2048 overscan inside amp ADSEC21 1 1024 1 2048 detector section only ASEC22 1082 2162 1 2048 amplifier section 22 UR de
14. server panview fpas _echelle config DETECTOR auto_mcb ucd SLOT00 MCB 0xDA3AE16 4 400000 dhe board lt type gt lt serial gt lt firmware gt SLOT02 CLK 0x0 4 200000 dhe board lt type gt lt serial gt lt firmware gt SLOT05 CCD 0xDA33CEE 4 110000 dhe board lt type gt lt serial gt lt firmware gt Identification of the panview focal plane name and the Data Handling system int this case the same panview PANID echelle PAN identification DHSID echelle DHS identification Comment as filled in the Comments control in the main Gui COMMENT none Shows the pixel time an peed mode used PIXTIME 8 9 pixel time SPEEDMOD normal speed mode used Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 27
15. tID 1 BSEC22 1082 1131 1 2048 bias section 22 UR detID 1 CSEC22 1082 2112 1 2048 ccd section 22 UR detID 1 DSEC22 1132 2162 1 2048 data section 22 UR detID 1 TSEC22 1132 2155 1 2048 trim section 22 UR detID 1 RSEC22 1082 2105 1 2048 roi section 22 UR detID 1 ABSEC22 1 50 1 2048 overscan inside amp ADSEC22 1025 2048 1 2048 detector section only ROISEC00 1 2048 1 2048 roi section Detector and Focal plane array FPA ID and detector characteristics Read out noise RON and gain in e adu as measured in the lab telescope DETECTOR2 Site424 6 Detector Identifier GAIN21 0 88 Gain for Amp A electrons adu RON21 6 6 Read Noise for Amp 21 electrons GAIN22 0 8 Gain for Amp B electrons adu RON22 7 2 Read Noise for Amp 22 electrons FPA ECHELLE_CT60 focal plan array Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 25 Observatory and telescope information OBSERVAT CTIO Origin of data TELESCOP CTIO 1 5 meter telescope Specific system Information of the TCS coming directly from the TCS and appended The comment fields are self explanatory DATE OBS 2009 12 22T11 21 42 0 date of observation start UT 11 21 42 0 UT of TCS coords RA 12 45 28 ra DEC 64 36 dec EPOCH 2000 epoch ALT 260 0 altitude HA 00 30 16 1 ha ST 05 04 01 1 sidereal time ZD 125 zenith distance AIRMASS
16. tch status of software command If the user turns ON IN the software switch the LED on the same box should also turn on showing that the actual control signal is ON IN this LED is actually showing a real feedback on the control signal Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 23 Appendix A Header This appendix present some information in the standard header and its meaning To consult how to edit add headers dynamically please refer to document ECH60S 3 0 on scripting Note that we describe only the keywords which are particular to this instrument not the standard fits keywords the keys that belong to the fits standard as NAXIS BZERO etc which are always present in any fits file Effective integration time shutter open time if object dark time if dark EXPTIME 12 Exposure time in secs date time of creation of the fits file DATE 2009 12 22T11 21 51 file creation date YY YY MM DDThh mm ss UT Title of the image as filled in the Observation title main GUI control OBJECT none Name of object observed Name of the observer as filled in the Observer main GUI control OBSERVER i observer Type of observation as chosen in the observation type drop down menu in the main GUI IMAGETYP object Type of picture object dark comp etc Image binning in x columns and y rows as selected in the Geometry Plug In CCDSUM 11 On chip summation X Y UT at wh
17. tor control signal is also an OR but now between the lamps control signals So if any lamp is ON the motor will be ON and any lamp will be ON if either its manual switch is ON or the software commands an ON DI m e x File Edit View Project Operate Tools Window Help Plugir n 10pt Application Font rana Lamps manual switches motor out Figure 3 3 Lamps Plug In The upper boxes manual switches motor out show the status of each manual switch name of the switch on top LED shows on off condition The last of the upper boxes shows the status of the motor labeled as MOTOR The lower boxes show the name of the lamp and the LED shows the status of the actual output control signal The switch in the box indicates the software switch status of software command If the user turns ON the software switch the LED on the same box should also turn on showing that the actual control signal is ON this LED is actually showing a real feedback on the control signal Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 21 The software provides some interlocks to avoid having two lamps turned on at the same time if the user turns on a lamp when the other is on he she will see in the gui that the old lamp gets turned off before the new one is turned on These interlocks are described in some details in document ECH60S 2 X on software architecture The so
18. tware provides a Graphic Interface GUI for an easy manual operation since the core of the software is ASCII commands driven using scripting is a natural way of handling the system So the user can use the GUI only or if he she prefers can run the software fully based on scripts of any type python csh tcl cl pearl or whatever the user prefer See the scripting reference manual for scripting details ECH60S 3 X The document describes how to startup and shutdown the software chapter 1 and also how to operate the main and auxiliary GUIs called Plug Ins chapter 2 and 3 As complimentary information there is a description of the fits headers on Appendix A Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 3 Chapter 1 Getting Things Running 1 1 Hardware Setup Before firing up the ECHELLE software there are two hardware parts that should be powered a Orange monsoon controller b Comparison Lamps control box The Lamps control box can be turned on after the software has started it just should be powered when the observation is in progress 1 2 Software Startup The user should be logged into the observer s account From the regular X window there are three ways of starting up the software a Icon click on the desktop icon called ECHELLE b type in any terminal or console start_ECHELLE c type in any terminal or console start_application ECHELLE The startup scripts located on HOME bin
19. xpansion and compatibility between systems you can have a common main gui for several different instruments Echelle User s Manual CTIO 60 inches Echelle ECH60S 1 3 16 3 1 Plug Ins gt DISPLAY The DISPLAY Plug In provides an interface to start and setup the real time display RTD The RTD is a graphic display that shows the last acquired image automatically The DISPLAY feature can currently use ds9 or ximtool as the actual displays This can be set on the configuration files see ECH60S 2 0 on system maintenance To start the DISPLAY Plug In the user can press the Display button at the bottom of the main GUI see 2 7 or press in the Plug Ins drop down menu and select DISPLAY from the list File Edit View Project Operate Tools Wing Oo Figure 3 1 Real Time Display Plug In Enable The round button with the green LED is to enable disable the RTD operation The start button allows to start the actual display device ds9 or ximtool as configured Scaling autoscale if set the RTD module will scale the gray levels as best as possible to have a good contrast In automatic mode it will always represent all the pixel values in the image If set the z1 z2 controls will be disabled grayed out If autoscale is not set then the z1 z2 controls will be available enabled There the user can enter the minimum z1 and maximum z2 pixel value to be represented This allows a better contrast in some desired

Download Pdf Manuals

image

Related Search

Related Contents

JVC DLA-SH4KNL User's Manual  Electrolux 60 - 70 Series Vacuum Cleaner User Manual  Z29511  Accounts Payable User Manual - The Texas A&M University System  Hunter 140 Owners Manual  3-in-1 INSECT & DISEASE CONTROL  Optoma ML500  Le Moniteur d`Issoire 1899-08-09 page 02  BEDIENUNGSANLEITUNG  Série ZK2  

Copyright © All rights reserved.
Failed to retrieve file