Home

USER MANUAL - Debenhams Plus

image

Contents

1. 0 000 m gt 1 year UK PRODUCT SUPPORT www appliancesdirect co uk Please for your own convenience make these simple checks before calling the service line 1 Is the unit plugged into the mains 2 Is the power supply OK 3 Have you cleaned or changed the filters if the unit lost efficiency 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit If the unit still fails to operate call 0871 620 1057 or complete the online form Office hours 9AM 5PM Monday to Friday www electriQ co uk Unit 2 The Nursery Berristow Lane South Normanton Derbyshire DE55 2FX
2. N A Controls and Settings AUTO HIGH MEDIUM LOW MODE 8H 4H 2H TIMER RESET ION UV POWER Air Quality LED EAP160HUVC multi stage air purifier is featuring an intelligent air quality sensor When air quality is poor the sensor LED light will turn RED When air quality is better the led will become pink When air quality is good the LED will turn to blue POWER Press POWER key and the air purifier will start operating at default medium speed ioniser and UV lamp will be on at the same time UV key turns on or off the UV light ION key turns on or off the plasma ioniser Ten mm ae When HEPA filter is replaced press Reset key for 5 seconds to reset the HEPA life cycle counter Timer key cycles between stopping timer operation 2 hour 4 and 8 hours stopping timer 8H 4H 4H AUTO HIGH MEDIUM LOW MODE MODE key cycles between 3 fan speeds Fan speed Low Medium High Troubleshooting The Air purifier does not 15 the power plug disconnected seem to work from the wall socket Is the socket switched on The front panel may not be installed properly please re install No clean air is delivered Please ensure filters are cleaned and the packing was removed from the filters Abnormal noise during Air inlet or outlets may be blocked operation Remove obstruction and try again this fails contact ElectrIQ su
3. electriQ EAP160HUVC Multistage Air Purifier True HEPA VOC filter UV lamp TiO2 photo catalysis PCO plasma ionizer advanced activated carbon USER MANUAL Thank you for choosing this innovative ElectriQ Air Purifier Please read this user manual before using the product and keep it safe for future reference Visit our page www electriQ co uk for our entire range of Intelligent Electricals CONTENTS SAFETY INSTRUCTIONS AIR PURIFIER FEATURES AND INDOOR POLUANTS OPERATION FILTER INSTALLATION DIAGRAM OF THE AIR PURIFIER CONTROL AND SETTINGS TROUBLESHOOTING APPENDIX AND TECHNICAL DATA Important e SAFETY INSTRUCTIONS Carefully read the instructions before operating the unit This appliance is for indoor use only Rating This unit must be only connected to a 220 240 V 50 Hz earthed outlet Installation must be in accordance with regulations of the country where the unit is used If you are in any doubt about the suitability of your electrical supply have it checked and if necessary modified by a qualified electrician This air purifier has been tested and is safe to use However as with any electrical appliance use it with care Disconnect the air purifier from socket when changing the filters or cleaning the unit Avoid touching any moving parts of the appliance Never insert fingers pencils or any other objects though the guard This device is not intended for use by persons includi
4. eria viruses dust mites and pollen etc Emissions from electronic office equipment Many studies including those from EPA and the University of California Berkeley have reported that emissions from office equipment like computers and printers etc include VOC s ultra fine particles and ozone These emissions have been proven to have a negative effect on the health of many people Using HEPA and Carbon Activated filters Plasma lonization VOC Filter TIO2 photocatalyst and UV light An effective HEPA filter is absolutely necessary to remove particles even at a microscopic level it ensures that the particles are not spread Plasma loniser will sterilise the air and reduce bacterial growth UV light dramatically improve Indoor Air Quality by destroying airborne bio contaminants such as viruses and bacteria which may be a leading cause infections and discomfort Ultraviolet air treatment systems have been used for more than 50 years in hospitals and various other healthcare industries but with the advent of small high efficiency UV Lamps now the technology finds place in the domestic environment Photocatalytic oxidation PCO is achieved when you combine UV light rays with a TiO2 titanium oxide coated filter Your ElectrIQ air purifier features an advanced VOC Filter coated with TiO2 filter This process of photo catalytic oxidation creates hydroxyl radicals and super oxide ions which are highly reactive electrons which will react with
5. ng children with reduced physical sensory or mental capabilities It is also not intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Do not leave children unsupervised with this device Do not clean the unit by spraying it or immersing it in water Use a damp cloth only Never allow water or vapours to enter the unit Do not clean with strong chemical agents or other abrasive materials Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the cord or power supply is damaged Ensure the power cord is not stretched or exposed to sharp object edges A damaged power supply should be replaced by the manufacturer Never extend or attempt to change the power supply lead Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to comply could result in a voided warranty Do not use the appliance for any other purposes than its intended use Avoid removing the power cord from socket while unit is still in operation This could cause electrical damage Never use the power supply as a switch to start and turn off the air purifier unit Use the provided ON OFF switch located on the control panel Alwa
6. other elements in the air such as bacteria and especially VOCs Once bound together the chemical reaction takes place between the super charged particle and the pollutant effectively burning oxidizing the pollutant This breaks the pollutant down into harmless carbon dioxide and water molecules making the air even cleaner The antibacterial activated carbon is a natural material biosynthesized from walnut shell the adsorption area of activated carbon is very large up to 900 000 square meters The activated carbon filter will absorb unpleasant odours and will help decomposing VOCs when combined with the TIO2 filter and UV light Operation Instructions Before first use Please remove any packing and plastic films before using your air purifier Please assemble the unit and install the filters as per filter changing instructions High performance True HEPA E and Advanced Activated Carbon D filters are not washable keep them dry at all times and vacuum regularly 1 Unplug the unit from the socket 2 Turn the unit around with front panel facing you 3 Press filter housing release buttons at the bottom of the panel insert fingers on the inside gaps then gently pull out the front panel to get access to filter chambers 4 replace the filters following full instructions When putting new filters in ensure always the front side is facing outward Only install filters in the order advised in this manual 5 The device should not be t
7. pport centre APPENDIX must be handled separately as special treatment is necessary K Disposal Do not dispose this product as unsorted waste Collection of such waste Recycling facilities now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to participating sites run by their local councils Please remember that this equipment will be further handled during the recycling process so please be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centres Technical Data Model EAP160HUVC CADR 160 CFM 272 m hr Fan Speed Low Medium High Airflow m3 hr 94 145 272 Noise level db 29 38 46 Power rating W 80 lons 3x10 ions cm Power cord length 1 8 meters Net Size wxdxh 39 6x 19 7x 61 5cm Net Weight 7 4 kgs Voltage 220 240 V 50 hz UV Lamp Size Power Rating Wave Length Life time T5 15 W 254 nm gt 9 000 hrs TIO2 Filter Size wxdxh Anti Bacterial Performance Particle Size Life Time 35 5x 0 7x 52 cm 99 Life of the unit HEPA Filter Size wxdxh Efficiency Particle Size Life Time 35 5 2 x 52cm 99 9 lt 0 00025 mm gt 1 year Carbon Activated Filter Size wxdxh Material Active Filter Life Time Absorption Surface 35 5 x 1 x52 cm Walnut Shell 90
8. to kill 99 9 of germs Plasma loniser sterilizes even further and removes mould spores and allergens from the air Also EAP160HUVC features air quality LED indicator that will help in monitoring the quality of the air Applications Personal use in domestic and office space to improve air quality Helps smokers to minimise the effects of smoking Helps asthma and pollen sufferers Schools hospitals hotels pubs and other public spaces to enhance clean standards Notes This air purifier is not a substitute for proper ventilation regular vacuum cleaning or for the use of a cooker hood while cooking If the humidity is over 60 Relative Humidity we recommend using a dehumidifier to reduce the humidity Information on Indoor Pollutants VOC Volatile Organic Compound VOC s come from motor vehicle exhausts gasoline vapour pollutants such as formaldehyde ammonia and many other common and chemical solvents like paints and glues or can be a by product of mould growth VOC s cause irritation to the eyes and or nose as well as causing headaches nausea and even potential damage to the central nervous system Pressed wood furniture newly decorated rooms paint and cleaning solvents are common sources of VOC s MOLD FUNGUS These can affect our respiratory system and cause allergic reactions like a runny nose eye and throat irritation headaches fatigue and aggravation of asthma Other indoor pollutants include bact
9. urned on until the sliding door is closed completely Installing or replacing the Filters Remove Front Panel Press filter housing release buttons 1 at the bottom of the panel insert fingers on the inside gaps then gently Place fingers inside the gap pull out the front panel Then slide the panel upwards on the direction of the control panel 2 Removal Installation of filters Rotary Knob io Rotate the filters locks with 180 degrees until filters are released Remove HEPA Carbon and the VOC TIO2 filter in this order If replacing the filters reverse the operation and lock back the rotary knob securing the filters in place Only remove the filters by pulling the rope 3 gently pulling rope NY Please make sure each filter is lined up correctly with Tio Coated Filter Carbon Filter HEPA filter rope facing outwards Re sitting the front panel Hook the front panel on to the rotary knobs and slide as shown by the direction of arrow 4 then push it into base Rotary Knob 90 and block groove the direction of arrow 5 Diagram of the Air Purifier gt 3 Ye o 8 g 3 g a 5 gt 2 5 re 5 2 I 2 5 Oo t lt 5 o o 2 2 9 ne goia 09 om c I 3 3 vu 8 our 0 3 5 5 m D gt ft Hp au lt L 2 0 mv Bu moa ss A
10. ys place the unit on a dry and stable surface The use of accessory attachments that have not been approved by the appliance manufacturer is not recommended as this may result in fire cause an electric shock and or cause personal injury Ensure hands are fully dried before plugging or unplugging the appliance The appliance should not be installed in laundry or wet rooms Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills For maximum performance and safety the minimum distance from a wall or objects should be 20 cm Keep away from other electrical appliances Keep the filters clean Under normal conditions filters should only need cleaning once every two weeks approximately Since the filters remove airborne particles more frequent cleaning maybe necessary depending on the air quality EAP160HUVC provides 6 stages air purification using professional air filtration and intelligent sterilisation technologies Advanced activated carbon filter removes unpleasant odours and absorbs harmful substances as formaldehydes and benzenes Antibacterial True HEPA filter to remove 99 9 of airborne particles of 0 25 micrometres or larger filter to remove toxic volatile organic compounds and unpleasant smells Ultra violet light UV light treatment to kill airborne bacteria germs and viruses 102 filter Titanium Dioxide screen to maximise UV effectiveness