1. PIX User Manual BB4 i I PIX contents INTRO RIGGING SET UP amp MODES SAFETY FIRST page 3 THE BB4 page 5 RIGGING page 6 SET UP page 9 MODES page 12 MODES A GRAPHICAL OVERVIEW page 15 OPERATING INSTRUCTIONS STAND ALONE FUNCTIONS page 16 STORING A DMX INPUT AS A MEMORY page 16 CREATING A MEMORY page 17 RECALLING A MEMORY page 19 CREATING A CHASE page 21 THE TECHNICAL STUFF TECHNICAL SPECIFICATIONS page 23 UNIT DIMENSIONS DRAWING page 25 TROUBLE SHOOTING page 26 QUICK RESET page 28 APPENDICES APPENDIX 1 ROHS COMPLIANCE AND WEEE DIRECTIVE INSTRUCTIONS page 29 APPENDIX 2 SERVICE CONTACT DETAILS page 30 BB4 USERS MANUAL PAGE 2 I PIX SAFETY FIRST ee The following symbols are used to identify important safety information in this manual A A A Warning Warning Warning Warning Safety hazard LED light Hazardous Fire hazard Risk of severe emission Risk voltage Risk injury or death of eye injury of lethal or severe electric shock Read this manual before installing powering or servicing the fixture follow the safety precautions listed below and observe all warnings in this manual If you have questions about how to operate the fixture safely please contact I Pix Warning Class 2M LED product Do not look into the beam from a distance of less than 40 cm 16 inches Do not stare into the beam for extended periods at a short distance Do not view the beam directly with
2. ch33 green high byte cell 4 ch34 green low byte cell 4 ch35 blue high byte cell 4 ch36 blue low byte cell 4 BB4 USERS MANUAL PAGE 14 MODES A GRAPHICAL OVERVIEW MASTER STROBE A INTENSITY CHANNEL Mode 1 Mode 2 Mode 3 Mode 4 Mode 5 3 ch 8 bit 6ch 16 bit 5 ch 8 bit 9 ch 16 bit 12 ch 8 bit COG aE sets Nu til Mode 6 Mode 7 Mode 8 Mode 9 Mode 10 24 ch 16 bit 14 ch8 bit 27 ch 16 bit 20 ch 8 bit 36 ch 16 bit NS The BB4 is able to run in a stand alone mode without any need of data from a lighting desk The light is capable of outputting up to 20 programmable memories and 1 chase that steps through these memories The light must be in MODE 3 5ch for all the stand alone functions to work However if you have access to a lighting desk a quick and easy way to create multiple or complex memories is to give the light the desired colour information using a lighting desk or similar DMX generating device and use the STORE function 1 Connect the light to the desk in the usual way making sure the address is correct and the lamp is in MODE 3 2 Create the desired colour on the lighting desk 3 Press the button underneath the MORE legend once PRESS 4 Press the button underneath the STORE legend once PRESS PRESS 5 You should then assign this memory a number using the UP DOWN buttons 6 When you are happy this memory has been numbered correctly pres
3. Directive In addition to containing no mercury the LED light engines have the following environmental advantages over traditional light sources High energy efficiency Long lifetime Fully dim able Very low IR and UV radiation For attachment of electrical connections I Pix use lead free solder WARRANTY STATEMENT I Pix seller extends warranty on all the electronics in the BB4 produced by the Seller for two 2 years from original date of shipment that the goods sold hereunder are new and free from substantive defects in workmanship and materials This warranty extends only to the Buyer and not to indirect purchasers or users Sellers liability under the foregoing warranty is limited to replacement of goods or repair of defects or refund of the purchase price at the Sellers sole option The above warranty does not apply to defects resulting from the improper or inadequate maintenance unauthorized modification improper use or operation outside of Sellers specifications for the product abuse neglect or accident THE ABOVE WARRANTY IS EXCLUSIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IMPLIED I PIX SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE I PIX Jan 01 2009 WARRANTY STATEMENT I Pix seller extends warranty on all the L E Ds in the 884 produced by the Seller for one 1 year from original date of shipment that the goods sold hereun
4. QUARTER TURN RIGGING POINTS i UNDERSIDE OF YOKE Unit 376 3rd Floor Broadstone Knoledge Mill Broadstone Mill Houldsworth Village Cheshire SK5 7DL Revisions date name description Drawn by date Chk App by date Drawing R Wray 10 10 07 number Customer I Pix Title Project BB BATTERN LIGHT CUSTOMER DRAWING 4 WAY BATTERN Drawing type Scale 1 1 Sheet 1081 Issue 1 File CUSTOMER 4 WAY BATTERN dwg in N lt n lt 2 lt D m m TROUBLE SHOOTING DISCLAIMER Please note that the information contained in this trouble shooting guide is generalized in nature amp cannot account for all possibilities Any proposed remedies for specific situations should not be considered as absolute or all encompassing Please seek professional assistance if there is any doubt as to the efficacy of a remedy or of the exact nature of any encountered problem I pix provides the information contained herein only as a guide No response from the light Does the LCD screen light up Yes Nb Is the LCD screen flashing Yes Nb There is no signal check DMX input gt No Does the unit have a good power supply Yes Nb Check the fuse is it blown Yes Nb Replace with the appropriate fuse 4A Contact l Pix for more specific help with your
5. USERS MANUAL PAGE 21 Now CHASE STRT chase start will appear along with the option MEM 1 This will be the first step of your chase Choose which memory you would like to be the first step of your chase using the UP DOWN buttons 6 Once you are happy with the memory that will be your first step press the button above CHASE STRT O O O Now CHASE END will appear along with the option MEM 1 This will be the last step of your chase The chase will run through all the memories numbered between the first and last step 1 Choose which memory you would like to be the last step of your chase using the UP DOWN buttons ace ele et 9 ee 7 Once you are happy with the memory that will be your last step press the button above CHASE END once Now you will be offered the option USE CHASE if you wish to simply press yes The Interface will now say CHASE RUNNING When you wish to end or change the chase press MENU e If you leave a chase running when the light is powered down the chase will resume as soon as the light is powered back up again If the chase does not run try rerecording the first step again BB4 USERS MANUAL PAGE 22 BB 4 Washlight tech spec Dimensions Length 600 mm Height 301 mm on rubber feet Width 147 mm Weight 13 5Kg total Yoke 3 KG Power Box 4 5Kg BB4 batten 6Kg Mechanical design materials used Batten Aluminium shrouded finned
6. are presented with the second colour GREEN default 0 In the same way if you wish to alter this value use the UP DOWN buttons to give you the desired If you require 100 press the DOWN button O 7 When happy with the GREEN value press the button above GREEN once O O Finally you are presented with the third colour BLUE default 0 In the same way if you wish to alter this value use the UP DOWN buttons to give you the desired If you require 100 press the DOWN button O 8 When happy with the BLUE value press the button above BLUE once O O BB4 USERS MANUAL PAGE 18 Now you are given the opportunity to store your memory If you are satisfied with all the values you have inputted If however you think you may have made a mistake or you have just changed your mind then you can return to the start of the memory by pressing MEM button and repeating the above process PRESS ee J 1 0 2 Ifyou are happy with you memory you should then assign it a number using the UP DOWN buttons 9 When happy with your memory number press STORE O O 0O BB4 USERS MANUAL PAGE 19 1 Press the button underneath the MORE legend once then 2 Press the button underneath the MAN manual legend once then PRESS O fig O 2 10 3 Press the button underneath the USE MEM use memory legend PRESS Now you will be offered the first memory MEM 01 This will come on aut
7. could look inside the unit and check the internal wiring for a lose connections shorts and also the power supply is working with a 15v output when there is no load connected to it Dmx trouble shooting The obvious It is good practice to connect data line and terminate before switching on device Is the dmx line fitted to a buffer and data is being received Is the dmx data line fitted with a line termination Does the unit s dmx mode set up match the personality profile for the console provided Note the LCD screen flashes intermittently when no data is present BB4 USERS MANUAL PAGE 27 QUICK RESET An easy way of returning the light to its default settings Before the light is given any power hold down both both buttons on the left hand side of the interface Keep the buttons held down as you give the light power When you see screen with the black boxes let go of the buttons and the next screen will appear If you do not let go it will stay locked until you let go Then the light will return to MODE 10 ADDR 001 This is a fast way of readdressing a light that will save you a few button presses BB4 USERS MANUAL PAGE 28 RoHS AND WARRANTIES I PIX 8845 COMPLY WITH RoHS RESTRICTIONS I PIX BB4s are compliant with all of the criteria proposed by the European RoHS directive 2002 95 EC for hazardous material content in electronic and electrical equipment as listed in Annex 1A and 1B of the WEEE
8. diagonal heatsink Power box Aluminium with steel base Yoke Folded and welded steel Finish Electro static powder coated black satin Rigging Style 16 turn camloc fasteners Number of positions 8 rigging locations on yoke Accessory holder Fitted with sprung retention flap Conventional mounts 2 of 12mm bolt holes fitted at each yoke end Note unit comes with three scaffold clamp adaptors to accept 12mm bolts equipped with two camloc turn bolts Electrical connections for mains and data in out Combined power and data connection Input Chassis mounted male 67 6 pin Output Chassis mounted female 67 6 pin Fixture feed Chassis mounted female 67 7 pin Fixture feed Trailing 7 pin male Mains and data Input inline female 6 pin Ceep Output 6 pin Ceep Electrical 120 watts total power on full Input 90 265 Volt 50 60 Hz Power 0 5 amps 240 volts Fuse 20mm x 5mm slow blow 4 amp Output to fixture 15 volts max Data type USITT DMX512 A Note units comes complete with 16 amp cee form plug and 5 pin xlr male A 1 metre combined power cable link is also supplied Control RGB additive colour mixing DMX channels 3 channels minimum 36 channels maximum User interface weatherproof backlit Icd display with four membrane switches BB4 USERS MANUAL PAGE 23 Modes 8 bit standard resolution 1 1x RGB over 4 cells 3 1x RGB over 4 cells with an overall master and strobe 5 4x RGB 7 4 x RGB with an overall master and strobe 9 4 x RG
9. is last used though the 0 backlight will come back on whenever any button is pressed O When you press the button above BACK OF the legend will change to BACK ON and the backlight will remain lit constantly BB4 USERS MANUAL PAGE 9 3 Select appropriate operating mode The BB4 will gives you a choice of ten operating modes These modes will enable you to set up the lamp in the most appropriate way for the many different jobs the lamp will be used for The nuts and bolts of the modes are described in detail in pages 12 to 15 To select a mode Keep the button below the MODE legend depressed go through the modes just before the one you desire stop then press once 4 Select appropriate DMX address First press the button above the ADDR legend Then change the address using the 100s 10s amp 1s buttons BB4 USERS MANUAL PAGE 10 5 inverting the cells Should you wish to change the running order of the cells so that instead of running 1NORM 4 shows the current they run orientation of the cells Press the button above 1NORM4 O CO THIS IS AN EXTREMELY USEFUL FUNCTION IF SOMEONE HAS RIGGED THE LAMP THE WRONG WAY ROUND To return them to press the button above 4INVRT1 D O O O 6 locking off the interface When you are satisfied that you have set up all the lamp s parameters to your liking it is possible to lock off the interface so that you dont inadvertently change anyt
10. problem as it could be an internal fault If you have the technical knowledge amp skills you could open up the unit amp Yes check for loose connections Mains supply keeps tripping out blowing fuses Does the mains supply trip before the light s are given power Yes Nb Check all external wiring for faults or the supply overloaded If problem persists contact a competent electrician gt No Does the mains supply trip when the light s are given power Yes Nb Is the mains supply overloaded with the addition of the lamp Yes Ny Remove some of the load from the supply upgrade the supply rating split the load across more circuits Contact l Pix for more specific help with your problem as it could be an internal fault If you have the technical knowledge amp skills you could open up the unit amp check for loose connections shorts amp faults GN no When you try the lamp on a different supply does it work Yes Ny Contact a competent electrician to check out the supply that could be faulty BB4 USERS MANUAL PAGE 26 TROUBLE SHOOTING The fuse on a unit repeatedly blows Are you fitting right rating type of fuse into unit Contact l pix for more specific help with your problem there may be an internal fault in the unit If you have the technical knowledge skills you
11. 4 green all cells ch5 blue all cells Mode 1 3 ch 8 bit Mode 2 6 ch 16 bit R Mode 3 5 ch 8 bit OF b MODE 4 9 channels 16 bit Ideal for fast programming or limited dmx line space with overall dimming amp strobe control and a greater resolution in control over the dimming and colours All 4 cells are treated as 1 with the 5 channels dim strobe red green amp blue affecting the whole lamp ch1 master intensity high byte all cells ch2 master intensity low byte all cells ch3 strobe all cells ch4 red high byte all cells ch5 red low byte all cells ch6 green high byte all cells ch7 green low byte all cells ch8 blue high byte all cells ch9 blue low byte all cells MODE 5 12 channel 8 bit Ideal for use with media servers where dmx line space may be a consideration Each cell can be individually coloured with its own red green blue channels most useful when each cell is patched individually 3ch ch1 red cell 1 ch2 green cell 1 ch3 blue cell 1 ch4 red cell 2 ch5 green cell 2 ch6 blue cell 2 ch7 red cell 3 ch8 green cell 3 ch9 blue cell 3 ch10 red cell 4 ch11 green cell 4 ch12 blue cell 4 Mode 4 9 ch 16 bit Mode 5 12 ch 8 bit BB4 USERS MANUAL PAGE 12 MODE 6 24 channel 16 bit Ideal for use with media servers with a greater resolution over the colours Each cell can be individually coloured with its own red green blue
12. B each with individual master and strobe 16 bit high resolution recommended 2 1 x RGB over 4 cells 4 1 x RGB over 4 cells with an overall master and strobe 6 4x RGB 8 4 x RGB with an overall master and strobe 10 4 x RGB each with individual master and strobe note 16 bit for every channel bar strobe which runs as 8 bit Note please refer to power box or user instructions or website for channel allocation details Most popular lighting desks have personalities available for download from their respective websites or the downloads section on our website Light Engine Source Customised lamina Titan RGB LED Wavelengths Red 625 Nm 2 5 Nm Green 517 Nm 2 5 Nm Blue 452 5 Nm 2 5 Nm Optics 4 x evenly spaced 20 degree optic note further photometric data and IES files are available for download from our website Thermal characteristics Fixture front Passive convection cooled Power box Force air cooled via low airflow low noise fans mounted to the base Operating temperature Minimum 20 degrees C Maximum 46 degrees C Weather protection Fixture front Hermetically sealed to IP67 Power box Mounted horizontally facing upwards Rated to IP65H Humidity max 20 90 RH non condensing Approvals amp Compliance BS EN 55103 1 Harmonics BS EN 55103 2 Immunity BS EN 61000 3 2 Emissions USA Canada ETL pending Lead and mercury free return to manufacturer for recycling IP Protection Patents filed in USA Manufactured in the
13. United Kingdom by I PIX We reserve the right to improve this fixtures design BB4 USERS MANUAL PAGE 24 Remove all burrs Surface to be a clean Tolerances unless otherwise stated and sharp edges finish and crevice free Up to 250 0 10 Are Sie kgs Anish Over 250 up to 1000 0 25 IF INDOUBT ASK All dimensions in millimeters mm Over 1000 l 0 75 BB4 FROUNT USER Ved Flic Ja d Coy q N PASSIVE g LJ HEAT SINK VENTS DO NOT COVER SUSPENSION YOKE a POWER DATA INPUT POWER BOX POWER DATA OUTPUT LV 884 OUTPUT SIDE VIEW 600 150 150 150 2 lt I FRONT VIEW DO NOT SCALE FROM PRINTS BEAM ACCESSORY SLOT WITH SPRING RETENTION TL Te y 7 opm o SAFETY BOND POINT S USER INTERFACE PASSIVE HEAT SINK VENTS DO NOT COVER SAFETY BOND POINT CAMLOC QUARTER TURN RIGGING POINTS END VIEW END VIEW POWER DATA INPUT POWER DATA OUTPUT LV BB4 OUTPUT
14. channel most useful when each cell is patched individually 6ch chi red high byte cell 1 ch2 red low byte cell 1 ch3 green high byte cell 1 ch4 green low byte cell 1 ch5 blue high byte cell 1 ch6 blue low byte cell 2 ch7 red high byte cell 2 ch8 red low byte cell 2 ch9 green high byte cell 2 10 green low byte cell 2 ch11 blue high byte cell 2 ch12 blue low byte cell 2 ch13 red high byte cell 3 ch14 red low byte cell 3 ch15 green high byte cell 3 ch16 green low byte cell 3 ch17 blue high byte cell 3 ch18 blue low byte cell 3 ch19 red high byte cell 4 ch20 red low byte cell 4 ch21 green high byte cell 4 ch22 green low byte cell 4 ch23 blue high byte cell 4 ch24 blue low byte cell 4 MODE 7 14 channel 8 bit Colour control over each individual cell with a master intensity and strobe having overall control over all 4 cells ch1 master intensity all cells ch2 strobe all cells ch3 red cell 1 ch4 green cell 1 ch5 blue cell 1 ch6 red cell 2 ch7 green cell 2 ch8 blue cell 2 ch9 red cell 3 ch10 green cell 3 ch11 blue cell 3 ch12 red cell 4 ch13 green cell 4 ch14 blue cell 4 Mode 6 24 ch 16 bit MODE 8 27 channel 16 bit High resolution colour control over each individual cell with a strobe and a high resolution master intensity having overall control over all 4 cells chi master intensity high byte all cells ch2 master intensity l
15. der are new and free from substantive defects in workmanship and materials This warranty extends only to the Buyer and not to indirect purchasers or users Sellers liability under the foregoing warranty is limited to replacement of goods or repair of defects or refund of the purchase price at the Sellers sole option The above warranty does not apply to defects resulting from the improper or inadequate maintenance unauthorized modification improper use or operation outside of Sellers specifications for the product abuse neglect or accident THE ABOVE WARRANTY IS EXCLUSIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IMPLIED I PIX SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE I PIX Jan 01 2009 BB4 USERS MANUAL PAGE 29 RoHS 2002 95 EC COMPLIANT WEEE COMPLIANT lt I PIX r SERVICE CONTACT DETAILS Broadstone Mill Broadstone Road Houldsworth Village Cheshire SK5 7DL Located 4 miles from Manchester airport and the city centre Tel 44 0 161 443 4140 E mail service i pix com www i pix com BB4 USERS MANUAL PAGE 30
16. er intensity all cells 4 ch17 strobe all cells 4 ch18 red cell 4 ch19 green cell 4 ch20 blue cell 4 Mode 9 20 ch 8 bit Mode 10 36 ch 16 bit til q MODE 10 36 channel 16 bit Ideal for control over all aspects of programming with high resolution master intensity high resolution colour control and a strobe control over each individual cell most useful when each cell is patched individually 9ch ch1 master intensity high byte cell 1 ch2 strobe cell 1 low byte cell 1 ch2 strobe cell 1 ch4 red high byte cell 1 ch5 red low byte cell 1 ch6 green high byte cell 1 ch7 green low byte cell 1 ch8 blue high byte cell 1 ch9 blue low byte cell 1 ch10 master intensity high byte cell 2 ch11 master intensity low byte cell 2 ch12 strobe cell 2 ch13 red high byte cell 2 ch14 red low byte cell 2 ch15 green high byte cell 2 ch16 green low byte cell 2 ch17 blue high byte cell 2 ch18 blue low byte cell 2 ch19 master intensity high byte cell 3 ch20 master intensity low byte cell 3 ch21 strobe cell 3 cell ch22 red high byte cell 3 ch23 red low byte cell 3 ch24 green high byte cell 3 ch25 green low byte cell 3 ch26 blue high byte cell 3 ch27 blue low byte cell 3 ch28 master intensity high byte cell 4 ch29 master intensity low byte cell 4 ch30 strobe cell 4 ch31 red high byte cell 4 ch32 red low byte cell 4
17. he fixture draws half and amp on full 240 volts BB4 USERS MANUAL PAGE 5 Rigging a BB4 horizontally To rig a BB4 horizontally use the OMEGA brackets supplied with the lamp These would have your clamp of choice bolted on to them The OMEGA brackets can be attached to each end amp the middle of the lamp using the camlocs First place the camloc pins in the receptacles with the levers facing out then to secure the brackets give the levers a quarter turn clock wise Make absolutely sure all four attachment points are secure BEFORE rigging the light ALWAYS secure the lamp to the truss pipe e t c with two safety bonds One attached to the lamp through the safety point shown in fig 1 the other attached to the yolk through the safety point shown in fig 2 NEVER through or to the brackets W fig 1 fig 2 BB4 USERS MANUAL PAGE 6 Rigging a BB4 vertically To rig a BB4 vertically use the SINGLE or DOUBLE YOLK hanging brackets The brackets can be supplied as accessories for the lamp You would obviously have your clamp of choice bolted on to them The YOLK brackets can be attached to the top middle or the lamp using the camlocs First place the camloc pins in the receptacles with the levers facing out the correct way Then to secure the brackets turn the levers a quarter turn clock wise W RO N G Q Q Q Q OF amp C o D
18. hing when focusing etc To lock off the interface depress the MORE and ADDR buttons simultaneously and the MORE will change to LOCK To unlock the interface depress the LOCK and ADDR buttons simultaneously and the LOCK will change to MORE BB4 USERS MANUAL PAGE 11 THE OPERATING MODES The BB4 has 10 different operating modes to suit different uses programming styles and dmx configurations MODE 1 3 channels 8 bit The most simple ideal for fast programming or limited dmx line space and as a node on a media server All 4 cells are treated as 1 with the 3 channels red green amp blue affecting the whole lamp chi red all cells ch2 green all cells ch3 blue all cells MODE 2 6 channels 16 bit Ideal for fast programming or limited dmx line space and as a node ona media server with a greater resolution over the colours All 4 cells are treated as 1 with the 6 channels red green amp blue affecting the whole lamp ch1 red high byte all cells ch2 red low byte all cells ch3 green high byte all cells ch4 green low byte all cells ch5 blue high byte all cells ch6 blue low byte all cells MODE 3 5 channels 8 bit Ideal for fast programming or limited dmx line space with overall dimming amp strobe control All 4 cells are treated as 1 with the 5 channels dim strobe red green amp blue affecting the whole lamp ch1 master intensity all cells ch2 strobe all cells ch3 red all cells ch
19. o o Do o Do o Do w o Do z BB4 USERS MANUAL PAGE 7 So after a quarter clockwise both levers should face each other in the centre WRONG TSS TSS e e NN K Y E ALWAYS secure the lamp to the truss pipe e t c with two safety bonds One attached to the lamp through the safety point shown in fig 1 the other attached to the LAMP yolk through the safety point shown in fig 2 NEVER through or to the RIGGING yoke WUUL Z Oe fig 1 fig 2 BB4 USERS MANUAL PAGE 8 SET UP 1 Select appropriate dimmer curve The BB4 offers a choice of two dimmer curves 1 LINEAR the output increases directly with dmx input 2 ENHANCED the first 10 of the output is controlled over the first 50 of the DMX input First press the button under the MORE legend PRESS PRESS Then press the PROFILE button PRESS Then select the appropriate dimmer curve linear LIN 1 1112 91225211 10 0 Or enhanced ENH O O BACK ON shows the current status of the backlight 2 Disable or enable user interface backlight Whilst in PROFILE you may choose to switch off the user interface backlight When you press the button above BACK ON the legend will change to BACK OF and the backlight will go out 5 seconds after the interface
20. omatically O O O 4 To select any other memory simply use the UP DOWN buttons until you find the memory you want 6 0 2 The memories will come on as you select them IF YOU WISH YOUR MEMORY TO COME ON AS SOON AS YOU GIVE THE LAMP POWER YOU WILL NEED TO PROGRAMME IT AS A TWO STEP CHASE WITH BOTH MEMORIES HAVING THE SAME VALUE To return to the main menu press the DMX MODE button BB4 USERS MANUAL PAGE 20 1 Ensure you have programmed all the memories that will go to make up the steps of your chase 2 Press the button underneath the MORE legend once 3 Press the button above the CHASE legend once Now the WAIT TIME will appear this is the first variable of the chase to be set The WAIT TIME is the time period between cross fades that the colour is held constant for Select the appropriate time in seconds using the UP DOWN buttons 4 When you are happy with the WAIT TIME press the button above WAIT TIME once Now the XFADE TIME cross fade time will appear this is the second variable of the chase to be set The XFADE TIME is the length of time the light takes to change from one colour to another Select the appropriate time in seconds using the UP DOWN buttons 5 Once you are happy with the XFADE TIME press the button above XFADE TIME once ol O 0 OBO 10 0 10 ee 0 2 15 ele 10 PRESS O 0 0 O 0 e O BB4
21. optical instruments This product is for professional use only It is not for household use This product presents risks of severe injury or death due to fire hazards electric shock and falls BB4 USERS MANUAL PAGE 3 PROTECTION FROM ELECTRIC SHOCK Shut down power to the entire installation at the building s main power distribution board and lock out power by removing the fuse for example before carrying out any installation or maintenance work Disconnect the fixture from AC power before removing or installing any cover or part and when not in use Disconnect the fixture from AC power before removing or changing the fuse Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Connect this fixture to AC power either using the supplied power cable or via 3 conductor cable that is rated minimum 20 amp hard usage Suitable cable types include ST SJT STW SEO SEOW and STO The voltage and frequency at the power outlet are the same as the voltage and frequency applied to the power inlet Only connect devices to the power outlet that accept this voltage amp frequency Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Do not use the fixture if the po
22. ow byte all cells ch3 strobe all cells ch4 red high byte cell 1 ch5 red low byte cell 1 ch6 green high byte cell 1 ch7 green low byte cell 1 ch8 blue high byte cell 1 ch9 blue low byte cell 1 ch10 red high byte cell 2 ch11 red low byte cell 2 ch12 green high byte cell 2 ch13 green low byte cell 2 ch14 blue high byte cell 2 ch15 blue low byte cell 2 ch16 red high byte cell 3 ch17 red low byte cell 3 ch18 green high byte cell 3 ch19 green low byte cell 3 ch20 blue high byte cell 3 ch21 blue low byte cell 3 ch22 red high byte cell 4 ch23 red low byte cell 4 ch24 green high byte cell 4 ch25 green low byte cell 4 ch26 blue high byte cell 4 ch27 blue low byte cell 4 Mode 7 14 ch 8 bit Mode 8 27 ch 16 bit BB4 USERS MANUAL PAGE 13 MODE 9 20 channel 8 bit Ideal for control over all aspects of programming where dmx line space may be a consideration For each cell there is individual control over master intensity strobe and red green colour mixing most useful when each cell is patched individually 5ch ch1 master intensity all cells 1 ch2 strobe all cells 1 ch3 red cell 1 ch4 green cell 1 ch5 blue cell 1 ch6 master intensity all cells 2 ch7 strobe all cells 2 ch8 red cell 2 ch9 green cell 2 ch10 blue cell 2 ch11 master intensity all cells 3 ch12 strobe all cells 3 ch13 red cell 3 ch14 green cell 3 ch15 blue cell 3 ch16 mast
23. s the STORE button wait 3 seconds and the display will return to the main menu PRESS 221 Ce 0 1 Ce Liaw UJ 9 884 USERS MANUAL PAGE 16 1 press the button underneath the MORE legend once O O 2 press the button underneath the MAN manual legend once PRESS 3 press the button underneath the PROG MEM program memory legend once PRESS 0 O 2 2 10 0 0 0 0 10 oj 0 ie You are now presented with the first variable of your memory which is the Master Intensity MINT The default value for the MINT is 100 intensity full If you wish to alter this value use the buttons above and below the UP amp DOWN legends until you have the desired value PRESS 0 4 When happy with the MINT value press the button above MINT once Next you are presented with STRB strobe the second variable of your memory which has a default value of 0 no strobe 03010 9 In the same way if you wish to alter this value use the UP amp DOWN buttons to give you the desired value BB4 USERS MANUAL PAGE 17 5 When happy with the STRB value press the button above STRB once Now you are presented with the first colour RED default 0 In the same way if you wish to alter this value use the UP DOWN buttons to give you the desired If you require 100 press the DOWN button 6 When happy with the RED value press the button above RED once O O Next you
24. t LEDs with magnifiers or similar optical instruments that may concentrate the light output BB4 USERS MANUAL PAGE 4 z 65 I PIX The BB 4 washlight provides the user with an energy saving high power light Four powerful light sources gives the feel and look of a modern light fixture LED in origin the appearance from the four blended sources shows no visible appearance of existing led technology yet has the performance we have all come to understand from this novel form of light The BB 4 washlight is equipped with four custom Light Engines from Lamina It s one of the highest power point source led light available It is the homogenized source of the three saturate colours that makes our colour mixing so good The performance of these light engines to i pix s exacting colour specifications gives a tighter tolerance and improved colour performance which makes tungsten lighting performance from the BB 4 possible Daylight temperatures can also be found with ease and finally a fixture that does not need a nudge from amber to compensate The whites are believable and full of low power energy which makes one wonder if the source is really an led engine The BB 4 has a super smooth control with 16 bit resolution enhancing the feel of the fixture when wishing to emulate the tungsten performance you would expect from pre existing fixtures Different operating modes ensure ease of use With consumption of 120 watts t
25. wer cable or power plug are in any way damaged defective or wet or if they show signs of overheating PROTECTION FROM FIRE Do not attempt to bypass thermostatic switches or fuses Replace defective fuses with ones of the specified type and rating only Provide a minimum clearance of 0 1 m 4 in around fans and air vents Do not modify the fixture Apart from I PIX accessories do not stick filters masks or other materials directly onto the light PROTECTION FROM INJURY Do not hang fixtures from each other Use two OMEGA clamps per fixture or I PIX SINGLE or DOUBLE YOLKS when suspending When suspending the fixture ensure that the structure and all hardware used can hold at least 10 times the weight of all devices suspended from them Use two secondary attachments such as a Safety cable to secure each fixture Secondary attachments must be able to hold at least 10 times the weight of all devices suspended from them and must be installed as described in this manual Check that all external covers and rigging hardware are securely fastened Block access below the work area and work from a stable platform whenever installing servicing or moving the fixture The LED emission presents a hazard to eyesight at a distance of 4 40 cm 1 6 16 inches when the eye is exposed to the beam for longer than 0 25 seconds Do not look at LEDs from a distance of less than 40 cm 1 ft 4 in without suitable protective eye wear Do not look a