Home

SRE 270 TC

image

Contents

1. 508 AC 50 Hz Burning time per tank hr 11 Electrical consumption igniter 240 W Capacity removable tank litres 7 1 continuous 44 W Weight kg 21 Fuse rating 250V 5A At maximum setting Specified values are indicative Q WARRANTY PROVISIONS Your heater comes with a 24 month warranty starting on the date of purchase Within this period all defects in material or workmanship will be repaired without any charge The following provisions shall apply regarding this warranty H 1 We expressly dismiss all other claims for damages including consequential damages 2 Any repairs or replacements of components within the term of warranty will not result in an extension of the term of warranty 3 The warranty shall no longer apply when the heater has been modified non original parts have been used or when it is repaired by third parties 4 The warranty shall not apply to parts that are subject to normal wear such as the burner mat and the manual fuel pump 5 The warranty shall only apply when you present the original dated proof of purchase provided no changes have been made to it 6 The warranty shall not apply to damages caused by actions not in compliance with the Directions for Use neglect and the use of an incorrect type of fuel or fuel past its use by date The use of incorrect fuel can even be dangerous 7 Transportation costs and the risks
2. e The first time you ignite your heater it will smell like new for a short time e Store your fuel in a cool and dark place e Fuel has a limited shelf life Start every heating season with renewed fuel e The right quality of fuel will be assured when you use Zibro Extra or Zibro Kristal for your heater e If you change to another brand and or type of parrafin oil you must first finish up all the remaining fuel in the heater MAIN COMPONENTS gt OG OG e 6 0 O 9 d 12 13 O Front plate Grid Base plate Lid for removable tank Operation panel Handle Removable tank Air filter cap Vent filter Thermostat Plug cord Information display O key Childproof lock Adjustment keys time and temperature TIMER SAVE key Indicator lights Connection Weektimer Only the use of the correct fuel will ensure safe efficient and comfortable use of your Zibro The fuel cap cover can be found at the rear of the heater This cover allows you to keep your hands clean when opening the fuel tank I ei AN This transportation cap is packed separately in the box Only this cap ensures trouble free transportation of the heater after use Store it well BE Bee WHAT YOU NEED TO KNOW IN ADVANCE ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION For each model the minimum size of space is specified in which you can use the heater safely without addit
3. most rigid tube into the jerrycan Make sure that it is in a higher position than the removable tank Fig D Insert the ribbed hose into the opening of the removable tank 4 Lock the switch button on top of the pump turn clockwise 5 Squeeze the pump a few times until fuel starts flowing into the removable tank As soon as this happens there is no need to press any longer a Check the removable tank fuel gauge while filling the tank Fig E Stop filling by loosening the switch button on top of the pump turn anti clock wise once the gauge indicates that the tank is full Never overfill the tank especially not when the fuel is very cold fuel expands when it heats up 7 Let the remaining fuel in the pump flow back into the jerrycan and carefully remove the pump Carefully screw the fuel cap back on the tank using the fuel cap cover After use re store the cover at the rear of the heater Clean off any spilled fuel 8 Check whether the fuel cap is straight and tightened properly Reinstall the removable tank in the heater cap down Close the lid C SETTING THE CLOCK It is only possible to set the correct time when the heater is connected to the mains and not burning Use the adjustment keys to set the time First press either of the two keys to switch on the function the CLOCK light and the information display
4. will start blinking Next set the hours using the key on the left F hour and the minutes using the key on the right min Press once to increase the value by one step When you hold down the key the value will continue going up until you release the key again After approximately 10 nen on seconds the blinking will stop and the setting will be locked 5 Minutes after indicator light stops blinking the setting has switching off the heater the information on the display will disappear and the been locked to the heater will automatically switch into the stand by position indicated value When the heater has been unplugged for more than 10 minutes or after a power failure the time needs to be set again IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Just press the 5 button Y to ignite the heater The button will start blinking indicating that the ignition procedure has started This will take a short while Once the heater is burning the 5 button will remain lit red The information display Q will show two numbers The light next to them indicates that these numbers refer to the temperatures Fig G The actual room temperature is indicated below Wii ME j Cd o E LI s ROOM while the temperature setting is indicated below SET The latter can be set room changed with the adjustment keys refer to Sec
5. changes Always store the fuel in a cool dry and dark place sunlight will affect the quality 8 Never use the heater in places where harmful gasses or fumes may be present e g exhaust gasses or paint fumes 9 Beware that the grid of the heater becomes hot If the appliance is covered there is a risk of fire 10 Always make sure that there is sufficient ventilation 100 cm 2 Defective electrical devices and batteries must be kept separate from household waste Ensure that there is effective recycling where possible Ask you local council or dealer for expert advice on recycling O DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL BV PVG Austria VertriebsgmbH Salaberg 49 3350 HAAG tel 43 7434 44867 fax 43 7434 44868 email pvgaustria zibro com PVG Belgium NV SA Industrielaan 55 2900 SCHOTEN tel 32 3 326 39 39 fax 32 3 326 26 39 email pvgbelgium zibro com PVG Schweiz AG Salinenstrasse 63 4133 PRATTELN tel 41 61 337 26 51 fax 41 61 337 26 78 email pvgint zibro com PVG Deutschland GmbH Siemensstrasse 31 47533 KLEVE tel 0800 9427646 fax 31 0 412 648 385 email pvgdeutschland zibro com Appliance A S Blovstroed Teglvaerksvej 3 DK 3450 ALLEROED tel 45 70 205 701 fax 45 70 208 701 email appliance appliance group com PVG Espafia S A Pol Ind San Jos de Valderas II Comunidad La Alameda C A
6. dk JE JE ELE SRE 270 TC MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING INSTRUKCJA OBSEUGI KULLANIM KILAVUZU Quarantee YEARS Dear Sir Madam Congratulations with your purchase of the Zibro the number one brand among movable heaters You have purchased a first class quality product which will serve you for many years to come This of course provided you use the heater correctly Please read these Directions for Use first to ensure maximum lifetime for your Zibro Your heater comes with a 24 month manufacturer s warranty on all defects in material or workmanship We wish you much warmth and comfort with your Zibro Yours sincerely PVG International b v Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST 2 IN CASE OF ANY DOUBT CONTACT YOUR ZIBRO DEALER 3 BEFORE YOU START READING FOLD OUT THE LAST PAGE gt GENERAL DIRECTIONS FOR USE Below you will find the main steps to be taken for using your Zibro For more details please refer to the MANUAL pages 45 ff Remove all packaging materials Fig A Fill the removable tank refer to Section B Fig D Insert the plug into the wall socket Ignite the heater using the key refer to Section D If required change the temperature using the adjustment keys refer to Section E Switch off the heater by pressing the key
7. gnite Use the key on the left Yhour to set the hours and the key on the right Amin to set the minutes interval of 5 minutes 3 After approximately 10 seconds the information display will show CLOCK again and the TIMER indicator light will light up indicating that the timer function has been activated Fig H 4 The timer will ensure that the room will have been heated to approximately the required temperature at the set time When you want to switch off the heater and ignite it again with the timer all you have to do is press the TIMER key refer to Section G Press the button once to clear the timer setting H The TIMER indicator light indicates that the G SWITCHING OFF THE HEATER timer function has been wihed on There are two ways to switch off the heater Press the button Y The information display will show the CLOCK signal Within approximately one minute the flame will have extinguished 2 Press the TIMER key without pressing the button when you want to switch off the heater and ignite it again with the timer the next time This not only switches off the heater but it also activates the timer function As long as the TIMER light and the information display are blinking you can change the required time with the adjustment keys refer to Section F H THE INFORMATION DISPLAY The information display not only serves as an indicato
8. hani Kat 6 35220 Alsancak IZMIR TURKEY tel 90 232 463 33 72 fax 90 232 463 69 91 email pvgturkey zibro com Printed in Japan 7826001921 man_SRE270TC gsc 070710 PVG Traffic
9. involved during the transportation of the heater or heater components shall always be for the account of the purchaser In order to avoid unnecessary costs we recommend that you always read the Directions for Use carefully first In case they offer no solution please take the heater to your dealer for repair Highly inflammable substances may induce uncontrollable burning causing flames to break out Should this happen never try to move the heater but always switch off the heater immediately In case of emergency you may use a fire extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 10 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence of a burning heater Do not move the heater when it is burning or still hot Do not refill nor service the heater when it is burning or still hot 3 Position the front of the heater at a distance of minimum 1 5 metres from walls curtains and furniture 4 Do not use the heater in dusty rooms or in very draughty places You will not have optimum burning in such rooms Do not use the heater in the immediate surrounding of a bath a shower or a swimmingpool 5 Switch off the heater before you leave or go sleeping Unplug the heater as well when you go away for a longer period of time e g holidays 6 Store and move fuel only in suitable tanks and jerrycans 7 Make sure that the fuel is not exposed to heat or extreme temperature
10. ional ventilation refer to Section P If a particular room is smaller than the specified space always leave a window or door slightly ajar 2 5 cm We also recommend doing this in highly insulated or draught free rooms and or at altitudes above 1 500 metres However if there is insufficient ventilation i e oxygen the heater will automatically switch off Do not use your heater in cellars or other underground areas THE RIGHT FUEL Only use Class C1 paraffin fuel in accordance with BS2869 Part 2 or equivalent Your heater has been designed for use with high quality water free pure paraffin oil such as Zibro Extra or Zibro Kristal Only fuels of this kind will ensure clean and proper burning Lower quality fuel may result in increased possibility of malfunctioning incomplete burning reduced heater lifetime smoke and or smells v v v v y deposits on the grid or mantle Using the right fuel is therefore essential for safe efficient and comfortable use of your heater Always refer to your local dealer for the right fuel for your heater A INSTALLING THE HEATER H Carefully remove your heater from the box and check the conten
11. lay will show the autocleaningcode 1 45 running back to A The procedure takes 5 minutes during which the heater will burn at its lowest setting while the burner autocleans When the burner is clean again the heater will automatically switch back to the highest setting again CHILDPROOF LOCK The childproof lock can be used to prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is on the heater can only be switched off Other functions are blocked then If the heater has already been switched off the childproof lock also prevents accidental ignition of the heater Activate the childproof lock by pressing the appropriate key and holding it down for more than 3 seconds The KEY LOCK indicator light will light up Fig 1 indicating that the childproof lock has been activated Switch off the childproof lock by pressing the key and holding it down for more than 3 seconds once again THE CORRECT USE OF SAVE The SAVE function allows you to limit the temperature When this function is activated the heater will automatically switch off when the room temperature exceeds the set temperature by 3 C Subsequently when the room temperature has dropped again to the set temperature the heater will automatically switch on again Activate the SAVE setting by pressing the appropriate key The SAVE indicator light will light up Fig J Switch off the function by pressing the SAVE ke
12. r of the set time and temperature Sections C E and F it also indicates any malfunctioning of the heater The code on the information display tells you what is the matter O A WN In case ofany malfunctioning the information display will tell you what is the matter I When the KEY LOCK light lights up the childproof lock has been activated J When the SAVE light lights up the heater will automatically switch on or off in order to remain within a specified temperature range BE Be CODE INFORMATION WHAT TO DO Es q Temperature within the heater too high Cool down and re ignite F d Power interrupted Re ignite the heater E i Faulty thermostat Contact your dealer F i Faulty burner thermistor Contact your dealer Es E Starting problems Contact your dealer Es Tipping over protection Re ignite the heater E amp Poor burning Contact your dealer Geo Room temperature If necessary above 32 C re ignite the heater E 8 Defective booster Contact your dealer ES Y Air filter dirty or Clean filter Fuel pump dirty Contact your dealer na Out of fuel Refill removable tank FUEL light binding Too little ventilation Ventilate better VENT light Always contact your dealer for any malfunctioning not listed above AUTOMATIC CLEANING MODE When the heater has been burning continuously for two hours at its highest setting the burner will automatically start an autoclean procedure The disp
13. se contact your dealer L A blinking VENT indicator light is a sign that you need extra M maintenance ventilation Switch off the heater and let it cool down before you start any maintenance work Also disconnect the plug from the mains M Your heater needs hardly any maintenance It is however important that you clean the air filter cap and the vent filter with a vacuum cleaner and the grid with a damp cloth both on a weekly basis Remove the air filter cap occasionally Fig M and clean it with soapy water Prior to reinstallation make sure that the air filter cap has fully dried Regularly inspect the fuel filter as well Remove the removable tank from the heater and remove the fuel filter Fig N Some drops may leak from the filter keep a cloth at hand Fuel filter N Remove the dirt by tapping the fuel filter upside down against a hard surface Never clean it with water w Reinstall the fuel filter into the heater We recommend that you remove dust and stains in time with a damp cloth because otherwise these may cause stains that are hard to remove Do not remove any heater components yourself Always contact your Zibro Y dealer for repairs When the power cord is damaged it may only be replaced by an authorised fitter Use a new cord of the type HO5 VV F N STORAGE END OF THE HEATING SEASON At the end of the heating
14. season you must store the heater in a dust free place if possible in its original packaging Unused fuel cannot be used in the next heating season We therefore recommend that you burn up all fuel If there is still some fuel left do not throw it away but dispose of it in accordance with the local regulations for the disposal of domestic chemical waste Always start the new heating season with fresh fuel When you start re using the heater follow the instructions again starting from section A and as specified O TRANSPORTATION Take the following measures to avoid fuel leakage during the transportation of the heater Let the heater cool down 2 Remove the removable tank from the heater and remove the fuel filter refer to Section M Fig N Some drops may leak from the filter keep a cloth at hand Store the fuel filter and the removable tank outside the heater 3 Place the transportation cap into the position of the fuel filter Fig 0 Press it tight transportation cap 4 Always move the heater in an upright position P SPECIFICATIONS Ignition electrical Dimensions mm width 704 Fuel paraffin including base plate depth 355 Capacity kW max 6 1 height 560 Capacity kW min 2 55 Accessories manual fuel pump Suitable space m 95 255 fuel cap cover transportation cap Fuel consumption l hr 0 635 Mains 230V Fuel consumption g hr
15. tion E G The required E SETTING THE REQUIRED TEMPERATURE temperature on the left The temperature setting can only be adjusted when the heater is burning Use the the measured temperature on the right switch on the function the TEMP light next to the information display will start adjustment keys to adjust the temperature First press either of the two keys to blinking Next adjust the temperature using the key on the right min to set the temperature to a higher setting and the key on the left Yhour to lower the temperature Press once to increase the value one step After approximately 10 seconds the light will stop blinking and the setting will be locked Fig G E The available temperature settings range from 6 C minimum to 28 C maximum When the heater has been unplugged for more than 10 minutes or after a power failure the temperature will reset to the factory setting of 20 C temp clock F USING THE TIMER The timer allows you to switch on the heater automatically at a preset time EV GE N dd o m l In order to switch on the timer the correct time must have been set refer to Section C and the heater should be off set room Follow the procedure below 1 Press the Oh button and then the TIMER key Y immediately after that The TIMER light on the operation panel will start blinking 2 Use the adjustment keys to set the time at which the heater must i
16. ts In addition to the heater you also need to have gt a manual fuel pump gt a transportation cap gt a fuel cap cover gt these directions for use Keep the box and the packaging materials Fig A for storage and or transportation 2 Open the lid of the removable tank and remove the piece of cardboard Attach the sticker to the inside of the lid 3 Fill the removable tank as indicated in Section B 4 The floor should be firm and completely level Reposition the heater when it is not level Do not try to correct the situation by placing books or other goods under the heater Please refer to the separate instruction in the carton box for fixing of the heater 5 Insert the plug into the wall socket 230 Volts AC 50 Hz and set the correct time using the adjustment keys refer to Section C a Your heater is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place there can always be some spillage Follow the procedure below 1 Make sure that the heater is switched off 2 Open the lid and lift the removable tank out of the heater Fig B Note Some drops may leak from the tank Put down the removable tank cap pointing upwards and screw off the fuel cap using the fuel cap cover Fig 3 Take the manual fuel pump and insert the smooth
17. urora Boreal 19 28918 LEGAN S Madrid tel 3491611 31 13 fax 34 91 612 73 04 email pvgspain zibro com PVG France SARL 4 Rue Jean Sib lius B P 185 76410 SOTTEVILLE SOUS LE VAL tel 33 2 32 96 07 47 fax 33 0 820 34 64 84 email pvgfrance zibro com Appliance Finland Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW10 9LT UK tel 44 1606 837787 fax 44 1606 837757 email sales scottmail co uk PVG Italy SRL Via Niccol Copernico 5 50051 CASTELFIORENTINO FI tel 39 0 571 628 500 fax 39 0 571 628 504 email pvgitaly zibro com Appliance Norge AS Vogellunden 31 1394 NESBRU tel 47 667 76 200 fax 47 667 76 201 email appliance appliance group com PVG International B V P O Box 96 5340 AB OSS tel 31 412 694 694 fax 31 412 622 893 email pvgnl zibro com Gardena Lda Recta da Granja do Marqu s ALGUEIRAO 2725 596 MEM MARTINS tel 35 21 92 28 530 fax 35 21 92 28 536 email pvgint zibro com PVG Polska Sp z oo ul Koscielna 110 26 800 Biatobrzegi tel 48 48 613 00 70 fax 48 48 613 00 70 email pvgpoland zibro com Appliance Sweden AB Sj gatan 6 25225 HELSINGBORG tel 46 42 287 830 fax 46 42 145 890 email appliance appliance group com PVG Is tma Klima So utma Ltd ti Atat rk Cad No 380 Ak Is
18. y once again Without the SAVE setting your heater will maintain the set temperature by approximation as well by adjusting its heating capacity SAVE is an economy setting which you can use when for instance you are not present in the room or to keep it frost free K THE FUEL INDICATOR LIGHT When the FUEL indicator light lights up there is enough fuel left for another 10 minutes of heater use The count down of the remaining heating time can be seen in the information display Fig K Every two minutes an alarm signal is sounded warning you to refill the removable tank If you do not react the heater will extinguish by itself The heater will also sound a warning signal when it switches off The FUEL indicator light will blink while four lines are blinking in the information display You can stop this by pressing the button Y once K When the FUEL indicator light is lit the information display will Once the heater has used up all its fuel and extinguished it will take some time show the number of after the refill before the heater is completely ready for use again minutes of fuel left in the tank L THE VENT INDICATOR LIGHT When the VENT indicator light starts blinking this is a sign that the room is not vented sufficiently Fig L If you do not provide additional ventilation the heater will switch off automatically after some time If the indicator light continues blinking after extra ventilation plea

Download Pdf Manuals

image

Related Search

Related Contents

Systems TWINDRIVE™ TD3 + HB20RF Systems TWINDRIVE™ TD3  (ACME)CP-64U HP日本語取扱説明書  Microsoft Word - Document1 - Societe  hvf-260 - user guide  VGN-SZ140PC  User's Guide  Samsung AQ18AWAX Инструкция по использованию  取扱説明書 Windows 2000編  [ 電子内視鏡 EB-530P ] ≫PDF  innovative technology IT-6022 User's Manual  