Home

User Guide - SNAP LightSense

image

Contents

1. Lightsense Occupancy Sensor User Manual and Installation Instructions This product is used in conjunction with the SNAP Wireless Lighting Products from Synapse Wireless Additional product information can be downloaded from synapse wireless com industry iot solutions lighting controls Product Overview ey The LightSense Occupancy Sensor LP201 001 can be installed in any indoor location where motion detection is needed The enclosed unit is a passive infrared sensor that detects movement within a specific N area by sensing the infrared energy emitted from a body as it moves d T as a part of a SNAP IEEE 802 15 4 wireless mesh network This network S through the sensor s field of view When in use the system will operate allows a sensor to transmit signals to other devices within the network eliminating issues caused by localized interference Powering On the Device To power on the SNAP LightSense Occupancy Sensor LP201 001 take the following steps Remove the cover on the main unit by gently prying the top and bottom housing apart at the line that surrounds the unit Locate the battery holding area and insert the enclosed battery per the directions noted on the plastic enclosure positive terminal should be closest to the green LED Light above After inserting the battery properly a green LED Light should turn on momentarily above the battery If the LightSense is being installed into an active SNAP L
2. ancy Sensor e Do not position the sensor facing windows fireplaces air conditioners area heaters heating vents or in direct sunlight Position the sensor on a rigid surface free from vibrations Mount the sensor at a height of approximately 6 7 feet depending on the height of the users Keep in mind that the sensor is aimed on a downward angle Avoid mounting sensors outdoors or in an area where they will be exposed to moisture or where the temperature is outside of the normal operating range e If the area of use has pets try to mount the sensor in an area where the pets will not activate the sensor Where possible mount sensors directly into a stud and if a stud is not available use the enclosed drywall anchors We do not recommend the use of double sided tape to mount sensors unless they are being mounted on a sensitive surface where the use of screws is not permitted e Walk test the area prior to mounting to ensure that the sensor covers the area appropriately After positioning the sensor using the guidelines above take the following steps to complete successful installation of the LightSense Occupancy Sensor LP201 001 Remove the cover on the main unit To do so gently pry the top and bottom housing apart at the line around the unit Locate the two pre drilled screw locations on the base plastic unit behind the sensor battery Mark the location of the holes where they are t
3. ighting mesh network it will next receive updated software Put the two plastic covers back together and be sure that they snap completely closed Using the LightSense Sensor at Your Site Once the sensor is powered on it will start communicating with the other sensors and the Site Controller LP400 001 Please refer to the SNAP Lighting user guide for more information on sensor operation LightSense devices will request an update to the configuration and firmware approximately every six hours If you desire an immediate configuration update please remove and reinsert the battery Mounting the Sensor To begin the sensor installation start by locating where the sensor should be mounted Keep in mind the following tips when choosing a location Position the sensor in an area where users will most likely walk across the detection area Be sure to mount the sensor in a direction that avoids unintended activations by users in other areas For instance do not mount the sensor facing into a hallway if it is intended to only detect occupants inside the room Position the sensor so it faces a solid reference point such as a wall Som 6723 Odyssey Drive Huntsville AL 35806 877 S na se 982 7888 Synapse Wireless com 2008 2015 Synapse All Rights Reserved All Synapse products are patent pending Synapse the Synapse logo SNAP 116 091514 004 000A and Portal are all registered trademarks of Synapse Wireless Inc Lightsense Occup
4. o be mounted and pre drill holes in the surface using an appropriately sized drill bit nsert the enclosed drywall anchors when appropriate Mount the sensor base using the enclosed screws e Replace the sensor battery e Replace the sensor top THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS iL THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`emploi du Twist 501  User Manual - SF-510/710 - Epson America, Inc.  Viewsonic VT1930 LCD TV  ATS LSD instruction manual  MANUEL D`UTILISATION Aspirateur Souffleur Broyeur  SYNQ SMP16.42 - user manual - only ENGLISH  Product User Manual - H-SAF  Précautions d`utilisation milliohmmètre Mode opératoire restreint du    Manual de usuario  

Copyright © All rights reserved.
Failed to retrieve file