1. and convenience and security These allow you to enter or leave the ENTRY DELAY premises through specified Delay Openings while the system is TIMES armed If you feel these delay times are unsatisfactory call your l installing company ABOUT THE MANUFACTURER Your new XL1218 Control Panel and Remote Digital Keypad are manufactured by Fire Burglary Instruments Inc leading manufacturers of quality reliable security control equipment since 1971 These products have been engineered using the latest advances in electronic and computer technology and are thoroughly tested by computer as well as quality control experts several times during the manufacturing process Fire Burglary Instruments warranties its products through your installing company Product Reliability and Ease of Operation are two of the major factors in the engineering design of all of Fire Burglary Instruments products so you can look forward to many years of trouble free service from your new security system lf you have any questions about the operation of your system call your installer Q a imire aeaiee Ai aaia TY E PES TR aa en ADDITIONAL NOTES 12153 Printed in U S A
2. problem has been corrected This is accomplished by repeating steps 1 and 2 above AMOMENTARY BEEP occurs whenever a key is depressed indicating that the system has received the number you have entered e Approximately 7 to 10 CONTINUOUS BEEPS is verification that your system has successfully reached the central monitoring station with a signal e STEADY BUZZING is a reminder to DISARM your system after entering the premises through one of the predetermined exit and entry zones OPTIONAL DIGITAL KEYPAD FUNCTIONS PANIC If your system has been designed to incorporate the panic option installer it will send a signal to the central station and may or may not sound pre set an alarm at your premises depending on the option you selected option To send a panic signal 1 Press and simultaneously for approximately 2 second NOTE If silent panic was selected you will not receive the verifi cation buzzer 2 To reset audible panic press for about second AMBUSH installer f your system has been designed to incorporate the ambush pre set Option you will program a special AMBUSH CODE for User 0 see option programming Ambush Code p 6 To send an ambush signal 4 Enter your User 0 5 Digit Ambush Code Example 0 6 4 3 7 or 2 Enter any other user number 1 3 plus User O s 4 Digit Ambush Code Example 2 6 4 3 7 NOTE If Ambush is not used your user 0 code will function l
3. AD LIGHTS Each green light corresponds to a particular zone number 1 4 Each may be on steady blinking or off at various times indicating different conditions of the zone Since your security system has been customized to suit your specific needs your installer will identify any 24 hour zones in your system The chart below shows the meaning of the green lights Burglary Zones To stop blink disarm system then press Reset wy 24 Hour Zones TROUBLE ZONE Each amber light monitors a particular function of your security system and is labelled accordingly If the function is operating normally the light is on AC light off the main electrical power supply is off FIRE light off trouble in the fire circuit i BAT TERY light off low battery back up power supply Light off System Disarmed Light on System Armed vi Slow blink Central Station did not receive transmission Fast blink Alarm condition TO stop blink press B Reset To stop blink disarm system then press al C Reset ON emee NRE IER en as THE KEYPAD BUZZER Trouble At the same time that any of the AMBER LIGHTS go off to indicate AC Fire Bat system problem a trouble buzzer may sound Installer option Buzzer To silence the trouble buzzer 1 Press i 9 Bypass 2 Press 0 Trouble Zone NOTE Remember to unbypass the trouble buzzer after the
4. THE USER FRIENDLY XL1218R Total Control at Your Fingertips so USER S GUIDE TO OPERATION aan and STATUS A C FIRE BAT XL1218 USER S GUIDE INTRODUCTION The brain of your new security system is the XL1218 Control Panel All of the detection devices of your system are wired to the control panel When a violation occurs the control panel reacts by setting the appropriate devices into action It may cause a siren to sound transmit a coded signal to the central station cause keypad lights to blink etc The XL1218 Digital Keypad will tell you the status of your security system at all times The following pages will familiarize you with the simple operation of the system via the Digital Keypad and will explain the meanings of the lights and buzzer TABLE OF CONTENTS Operation page arming the System cece ee ccc eee ee ee cee eees 1 instant home feature cece eee eee eee eee eee ee 4 disarming the System cc cece cece cece tent e ee eeee 4 ZOnE DYDOSS ae De sae d select DRED RANGER 2 zone reactivation unbypass 6 ec ec ect ec ete ees 2 keypad lights ce seta seed Eina 84 ar Sw ied AEG 3 KEVDOO DUZZOM ssc deletes enact Er mn aa Pavey ee oe eee 4 panic installer pre set OPTION 6 eee ccc cece etna 4 Ambush installer pre set Option 1 1 0 0 cece cece ee eens 4 Programming fallback code nesrin ba woes iMate e andes 5 USCIS GETING yi ches cen b
5. e eel el dee sale Page Ae OE NA 5 arm disarm codes cece ccc eee cc et ener tee eenneeeeenes 5 CAMBUSN CODE rrari cue pean ERE EETA Ma wedi ek 6 rasiga COE se cence endo emir eeeewb bd banaaw ene Onis 6 CHANGING G code ie beck he ed aetna ged ha ated ethos ow 6 exit and entry delay 1 0 0 cece ccc cc cnet eee e neces 6 Instant Home Feature ARM DISARM OPERATION To arm your security system with no zones bypassed 1 Make sure that all of the Zone Status green lights are lit If any of the green lights are off the number will show you which zone has an open loop open window etc You cannot arm the system with an open loop Once all protected openings are secured 2 Enter your 5 digit secret code by gently depressing each number key until you hear a momentary beep 3 When all 5 digits have been entered the red ARM light will go on and all of the green zone lights will go off You now have a pre set amount of time exit delay time to leave the premises through a door designated by your installer as a delay zone Neh If you are staying within the premises and no one is expected to return while the system is ARMED you will want your time delay doors to report an Alarm instantly This is accomplished by selecting the INSTANT option To select the Instant option 1 Arm the system 2 Press E 3 The zone 1 green light will go on NOTE This option automatically reset
6. ike all other user arm disarm codes gg ARM DISARM CODES USER 4 CODE KEYPAD PROGRAMMING Your system is preprogrammed with a FALLBACK ARM DISARM CODE Be sure to record this code In the event of a total loss of power AC and battery all codes with be erased Your Fallback code will enable you to arm and disarm the system and re program your personal secret code As many as four separate arm disarm codes can be programmed Each code must begin with a different digit which we call the User Number for example User 1 s arm disarm code would be 1 and any four additional numbers User 2 s code would be 2 and any four additional numbers etc It is not necessary to program all four codes A user code may be programmed for temporary use for a service person guest etc and then erased see below when no longer needed This maintains the secrecy of your regulary used codes THE SYSTEM MUST BE IN A DISARMED MODE TO ACCOMPLISH ANT PROGRAMMING ALL PROGRAMMING IS DONE USING USER 4 s CODE functions as an authorization ee THE NUMBER 9 MAY NOT BE USED IN ANY CODE To Program User 1 s Arm Disarm Code 1 Press iL a Key 2 Press number 1 then the 4 Digit FALLBACK CODE 3 Press Ial again The Zone 1 Green Light will blink slowly e Now Press Any 4 Numbers Desired For User 1 s Code Do not use 9 Upon completion of the 4th digit the zone 1 light will stop blinking 4 Test the
7. new code by attempting to arm the system NOTE Remember to DISARM the system before attempting to pro gram any additional codes 1 Press Code key 2 Enter your New User 1 Authorization Code 3 Press 2 Tne Zone 1 Green Light Will blink slowly e Now press the 4 Numbers Desired for isa 2 s Code Do not uf S Upon completion of the 4th digit the Zone 1 light will stop blinke iQ Repeat for User 3 and 0 User O s Code may be programmed exactly as all other user codes only if the keypad AMBUSH feature is not used This feature is pre set by your installing company if desired See explanation of AMBUSH below Ambush is a 4 digit code that will either turn the system ON if it is off or OFF if it is on AT THE SAME TIME it will send a SILENT EMERGENCY SIG NAL to the central monitoring station The Ambush Code is pro grammed as User 0 following standard USER CODE PROGRAMMING as described on page 5 User 1 can erase any user s code except his own as follows 1 Press Code Key 2 Enter User 1 Code 3 Press User Number of Code to be Erased e g if User 2 Code is to be erased depress only the number 2 to erase entire code 4 Press Reset Key Repeat Steps 1 2 and 3 above entering User Number of code to be CHANGING changed in Step 3 A USER CODE 4 Enter new 4 digit code desired do not use 9 The exit and entrance delay times have been previously set for your EXIT
8. s when the system is disarmed To disarm your security system 1 Enter your 5 digit secret code 2 The red ARM light will go off Fane If you wish to arm only a part of your system such as the front doors B and windows but still have the freedom fo come and go for in YPASS stance through the back door you may bypass the desired zone s i and then arm the rest of the system To bypass one or more zones 1 Make sure that the system is disarmed red light off 2 Press 9 Bypass 3 Press the mumber of the zone to be bypassed Example To bypass zone 3 Press E then 4 The green zone light will blink slowly to indicate that that zone is bypassed gt amp NOTE To bypass additional zones repeat steps 2 and 3 above 5 Now arm the system by entering your 5 digit code All of the green lights will go off the red light will go on Under normal conditions bypassed zones are automatically reactivated unbypassed when the system is disarmed However Reactivation AFTER A BURGLARY ALARM you must manually unbypass any Unbypass bypassed zones Zone To Unbypass a single zone 1 System must be disarmed Press Press number of the zone to be unbypassed KR WwW N The green zone light should stop blinking OR To Unbypass all bypassed zones 1 System must be disarmed 2 Press Reset Green Zone Lights Amber Status Light Red Arm Light KEYP

Download Pdf Manuals

image

Related Search

Related Contents

Micronet SP3130 CF GPS Receiver  manual de instruções termo de garantia manual de instruções termo  Honeywell Smoke Alarm IPGSM-DP User's Manual  Tipo 161EB - Welcome to Emerson Process Management  DS5中文使用手册下载  Order Catalogue 2012  Epson S5 User Replaceable Parts List  ELMO Manuale Tecnico CF4Z  Manual de instrucciones  