Home
SIPLUS CMS4000 X-Tools - User Manual
Contents
1. contains the type of the location The information within the Offline File Locations table can not be edited by the user In order to add remove an offline file location the according operations from the context menu of the Offline Data Files tree are being used 2 4 2 3 CMS2000 Date Structure Table The CMS2000 Date Structure table is used in order to specify the depth of the date structure which shall be shown for CMS2000 files Column Description No contains the row number Content contains Configuration in row number 1 and Example in row number 2 Year defines whether the year shall be shown defines whether a directory split shall be made between year and month Month defines whether the month shall be shown defines whether a directory split shall be made between month and day Day defines whether the day shall be shown Changes to the CMS2000 Date Structure table are being taken over after the Apply menu button has been pressed The ODL Standard T001 can load databases which have been created by V 1 x or V 2 x of the SIPLUS CMS2000 system English Release 2012 09 35 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 4 2 4 2 4 2 4 1 Offline Data Files Tree Overview The Offline Data Files tree displays all of the items which are available for the ODL Standard T001 Each branch of the Offline Data Files tree has a defined task and provides c
2. Source Module contains the source module of the entry Source Machine contains the source machine of the entry Source User contains the source user of the entry Priority Class contains the priority class of the entry Execution ID contains the execution ID of the entry 2 4 2 6 Menu Bar Menu Button Description Cancel Loading This button cancels the currently ongoing offline data loading In case there are additional re quests for loading of offline data being present within the internal execution queue of the X Tools Server also all of these additional requests are being cancelled All of the already loaded parts of offline data stay in the memory of the server and is available via the MDS Explorer Close This button closes the ODL Standard T001 A possibly ongoing offline data loading is not affected by closing of the ODL Standard T001 and is continued until all data is loaded 2 4 2 7 Dropping of Items Dropped Item Description Server Branches starts the ODL Standard T001 with the contents of the dropped X Tools Server 2 4 2 8 2 4 2 8 1 Add Location Dialog Overview The following screenshot shows an example of an Add Location dialog English Release 2012 09 No Parameter E Location Type X Tools Offline Data Files sdf xts Cancel Figure 8 Example of an Add Location Dialog 37144 SIPLUS CMS X Tools User Manua
3. 2 4 2 11 Advanced Export Dialog 2 4 2 11 1 Overview The following screenshot shows an example of an Advanced Export dialog Exporting Parameters SIPLUS CMS No Parameter Export Location Offline Files Export Path Offline Files Export File Type csv Comma separated Values 05 Timestamp Format ns 06 Decimal Precision Automatic Export Mode Default 08 Export Parameters N A 09 Time Input Mode Default Time Domain N A Minimum Time Format N A Minimum Time Yalue N A Time Interval Format N A Time Interval Value N A Maximum Time Format N A Maximum Time Yalue N A Figure 11 Example of an Advanced Export Dialog 2 4 2 11 2 Exporting Parameters Table The Exporting Parameters table contains parameters which shall be applied when the selected offline data is being exported Parameter Description Used Loading Profile displays the currently chosen Loading Profile a double click onto this control opens the Select File dialog in order to choose another Loading Profile Export Location allows to switch between the already defined storage export locations and to define additional storage export locations Export Path allows to choose the desired path below the specified storage export location Export File Type allows to switch between the available export file types Timestamp Format allows to switch between the available timestamp formats Decimal Precision allo
4. When the time domain is set to Absolute Times the Minimum Time Value and Maximum Time Value rows expect the user input as absolute times Relative Times When the time domain is set to Relative Times the Minimum Time Value and Maximum Time Value rows expect the user input as relative times 2 3 3 7 Excluded Data Table The Excluded Data table contains all of the data which shall be included when offline data is being loaded Column Description No contains the row number Enabled specifies whether the configuration within this row shall be considered when offline data is being loaded or not Name contains the name of the data The user is able to highlight a complete row or multiple rows and to delete them via the context menu Re move context menu item and or via the keyboard Del key A highlighted row or multiple rows can be copied cut pasted to another row of the Excluded Data table of the current or any other Loading Profile Editor via mechanisms of the context menu Copy Cut and Paste context menu items and or via the keyboard lt Ctrl C gt lt Ctrl X gt and lt Ctrl V gt keys Any data which is copied from the Excluded Data table of a Loading Profile can be copied to the Included Data and Excluded Data tables of other Loading Profiles as well as to the Data table of Storage Profiles The last row of the Excluded Data table always is an empty row except the Na
5. 2 3 3 3 SIPLUS CMS Loading Profile Parameters Table The Loading Profile Parameters table contains all of the profile dependent parameters which can be configured within a Loading Profile Parameter Description Data Filter allows to switch between the available data filters Time Filter allows to switch between the available time filters Data Filter Data Filter Description None When the data filter is set to None all configurations from the Included Data and Excluded Data tables are ignored when offline data is being loaded Use included Data List When the data filter is set to Use included Data List only the data which are configured within the Included Data table are loaded as offline data and all data configurations from the Excluded Data table are ignored when offline data is being loaded Use excluded Data List When the data filter is set to Use excluded Data List all data except the data which are config ured within the Excluded Data table are loaded as offline data and all data configurations from the Included Data table are ignored when offline data is being loaded Time Filter Time Filter Description Use default Times When the time filter is set to Use default Times the time configurations from the Default Time Configuration table are used when offline data is being loaded and all time configurations from the Included Data table are ignored when offl
6. Branch ae eek IH ast aves dees head 13 2 1 17 Storage Process Modules Branche 13 2 1 18 Storage Process Module Branche 14 2 2 Storage Profile Editors ie eR aed tines ERE 14 2 2 1 eri C M 14 2 2 2 Gommon Controls 2 2 Loic ose Hedge tibt aller iudex udo eu ez dor nd 14 2 2 2 1 rcu REP 14 2 2 2 2 Storage Profile Settings Table emen 14 2 2 2 3 Men Bap hetero ee de tanec neues 15 2 2 3 SPE Binary TOOT ete Hio eto de er Oa eta dades te digi ed 15 2 2 3 1 OVOIVIOW Lo en cate tutae dan e e E Ent e b 15 2 2 3 2 Storage Profile Settings Table emnes 16 2 2 3 3 Storage Profile Parameters Table 16 2 2 3 4 Path and File Name Configuration Table em 17 2 2 3 5 Fie Splitting Table D a egeta e gti cnt nadie 18 2 2 3 6 Start Event Table it aaa e e CO ed ede HE adea eod ed ia 19 2 2 3 7 Stop Event Table 20 22 5 5 ree dette itti iniquitates S 21 2 2 3 8 Pre Trigger Table reo Et etta 22 English Release 2012 09 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 2 3 9 2 2 3 10 2 2 3 11 2 2 3 12 2 2 3 13 2 2 3 14 2 2 3 14 1 2 2 3 14 2 2 2 3 15 2 2 3 15 1 2 2 3 15 2 2 2 3 16 2 3 2 3 1 2 3 2 2 3 2 1 2 3 2 2 2 3 2 3 2 3 3 2 3 3 1 2 3 3 2 2 3 3 3 2 3 3 4 2 3 3 5 2 3 3 6 2 3 3 7 2 3 3 8 2 3 3 9 2 4 2 4 1 2 4 2 2 4 2 1 2 4 2 2 2 4 2 3 2 4 2 4 2 4 2 4 1 2 4 2 4 2 2 4 2 4 3 2 4 2 4 4 2 4 2 5 2 4 2 6 2 4 2 7 English Release 2012 09 oeren
7. Example of a LPE Standard TO 29 Example of an ODL Standard T001 sss eene enne enne 34 Loading Progress Dialog e et tec et eec nn atre d eniin ed ed e Line de anne ee 37 Example of an Add Location Dialog ssssssssssssseene eene emnes 37 Example of an Advanced Append Dialog 38 Example of an Advanced Overwrite Dialog 40 Example of an Advanced Export Dialog 41 Release 2012 09 6 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 1 Preface 1 1 Purpose of this Document This document provides detailed information about the functionalities and usage of the software e SIPLUS CMS X Tools of the SIPLUS CMS product line In addition to the detailed information about each dialog and functionality of the Storage System which is found within this document also the following documentation is available e SIPLUS CMS X Tools User Manual 01 Introduction o provides an introduction into the basic functionalities of SIPLUS CMS X Tools e SIPLUS CMS X Tools User Manual 02 Master Data System o provides detailed information about the functionality which is provided by the Master Data System e SIPLUS CMS X Tools User Manual 03 Main Management System o provides detailed information about the functionality which is provided by the Main Management Sys tem e SIPLUS CMS X Tools User Manual 04 Device Management System o provides detailed information about the
8. Instead the last known value from the ring buffer is put into the file each amount of time which is specified as interval Storage Parameter Storage Parameter Description N A This storage parameter is relevant for the storage mode Each Value only and is being applied automatically in case this storage mode is being chosen Hysteresis This storage parameter allows specifying via edit box the hysteresis for to be stored values and is being applied automatically in case the storage mode Changes Only is being chosen Hysteresis and Interval These storage parameters allow to specify via edit box the hysteresis and the amount of time for the to be stored values and are being applied automatically in case the storage mode Changes and Interval is being chosen Interval This storage parameter allows specifying via edit box the amount of the time for to be stored val ues and is being applied automatically in case the storage mode Interval Only is being chosen 2 2 3 13 Menu Bar The standard Menu Bar is being used by the SPE Binary T001 see point 2 2 2 3 2 2 3 14 2 2 3 14 1 Path Configuration Dialog Overview The following screenshot shows an example of a Path Configuration dialog Path Configuration Elements Milli Second Micro Second Data Name Storage ID 1 Storage ID 2 Storage ID 3 Backslash X Dash Dot Space Underscore _ j Path Configuration Storage Profile P
9. Name contains the name of the data Unit contains the unit of the data Status contains the current status of the data Storage Mode contains the storage mode of the data Storage Parameters contains the storage parameters of the data The user is able to highlight a complete row or multiple rows and to remove them via the context menu Re move context menu item and or via the keyboard lt Del gt key In order to put some data definition into an empty row a new valid data name can be entered or the definitions from another row can be pasted into the empty one New data definitions also can be added via copy move operations of existing data definitions from other Storage Profiles of matching type A highlighted row or multiple rows can be copied cut pasted to another row of the Data table via mechanisms of the context menu Copy Cut and Paste context menu items and or via the keyboard lt Ctrl C gt Ctrl X and lt Ctrl V gt keys Any data which is copied from the Data table of a Storage Profile can be copied to the Data table of other Stor age Profiles as well as to the Included Data and Excluded Data tables of Loading Profiles The last row of the Data table always is empty except the Name cell see below and therefore allows the user to add a new data by typing another name into the Name field of this last row All other cells of the last row are empty and disabled as long as the Name field is empty Whenever a
10. Value rows expect the user input as relative times English Release 2012 09 43144 SIPLUS CMS X Tools User Manual 07 Storage System 3 Contact Information Address Siemens AG IA CE SE Wuerzburger Strasse 121 90766 Fuerth Germany Internet http www siemens com siplus cms English Release 2012 09 SIPLUS CMS 44 144
11. a Storage Profile opened already it is closed automatically before the new one is being created Open This button opens the Open dialog where the user is able to select the file which shall be opened Save This button saves the currently opened Storage Profile to the currently known storage location In case the storage location has not been defined yet the Save As dialog is popping up automati cally and the user is able to select the desired storage location Save As This button opens the Save As dialog where the user is able to select the desired storage loca tion Close This button closes the editor In case the currently opened Storage Profile is not saved the editor asks the user whether the Storage Profile shall be saved before it is closed 2 2 3 SPE Binary T001 2 2 3 1 Overview The SPE Binary T001 is used in order to visualize create and edit Storage Profiles of type Binary T001 Mul tiple editors of this type can be opened and used simultaneously The following screenshot shows an example of a SPE Binary T001 Storage Profile Settings Storage Profile Parameters Path and File Name Configuration File Splitting Start Event Stop Event Pre Trigger Post Trigger Disk Clean Up Disk Limitation Data Enabled ION Analoglnput T001 CHO1 ION Analoglnput T001 CHO2 ION Analoglnput T001 CHO3 ION Analoglnput T001 CHO4 ION amp naloglnput T001 CHOS ION Analoglnput T001 CHO6 ION Analo
12. between the available input formats for the minimum time Minimum Time Value allows to enter the minimum time of the data which shall be loaded Time Interval Format allows to switch between the available input formats of the time interval Time Interval Value allows to enter the time interval of the data which shall be loaded Maximum Time Format allows to switch between the available input formats for the maximum time Maximum Time Value allows to enter the maximum time of the of the data which shall be loaded Time Input Mode Time Input Mode Description Default In this time input mode the time configuration from the Default Time Configuration table is used when offline data is being loaded Minimum Time and Time Interval In this time input mode the specified Minimum Time Value and Time Interval Value parameters are used when offline data is being loaded Minimum Time and Maximum Time In this time input mode the specified Minimum Time Value and Maximum Time Value parameters are used when offline data is being loaded Time Interval and Maximum Time In this time input mode the specified Time Interval Value and Maximum Time Value parameters are used when offline data is being loaded English Release 2012 09 32 44 SIPLUS CMS X Tools User Manual 07 Storage System Time Domain SIPLUS CMS Time Domain Description Absolute Times
13. case the full path directory path file name of the to be stored file exists already the old file is overwritten with the new values from the current storing the contents of the new file are the same as if the old file would not have existed Do not store the new File in case the full path 7 directory path file name of the to be stored file exists already the old file is left unchanged and the newly to be stored values are not being stored Storage ID 1 The desired data for the Storage ID 1 either can be set through Drag amp Drop from the MDS Explorer or through typing of its name by hand In case a Storage ID is used within the directory path and or the file name configura tion its value at the moment of the start event is inserted into the directory path and or file name The value always is interpreted as Integer and is formatted without any leading zeros Storage ID 2 See Storage ID 1 Storage ID 3 See Storage ID 1 2 2 3 5 File Splitting Table The File Splitting table contains all of the settings which are relevant for the file splitting of data files Depending to the configurations which are chosen within the File Splitting table the according columns from the table below are being used and not all columns may be visible simultaneously Column Description No contains the row number Splitting Mode contains the splitting mode Splitting Interval Format contains the splitting interva
14. data Overwrite overwrites the already present offline data with the data from the selected items Export exports the data from the selected items Advanced Append opens the Advanced Append dialog and appends the data from the selected items to the already present offline data with the chosen options afterwards Advanced Overwrite opens the Advanced Overwrite dialog and overwrites the already present offline data with the data from the selected items according to the chosen options afterwards Advanced Export opens the Advanced Export dialog and exports the data from the selected items according to the chosen options afterwards Delete deletes the selected items While the appending overwriting or exporting of the offline data is going on the Loading Progress or Export Progress dialog is being displayed The Cancel button can be used in order to cancel any ongoing loading or export operation English Release 2012 09 36 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 4 2 5 Preparing to load There are 1 file s to append A Cancel Figure 7 Loading Progress Dialog Log Entries Table The Log Entries table contains all of the events which apply to the loading of offline data Parameter Description No contains the row number Date and Time Entry contains the date and time of the entry contains the text of the entry
15. is being selected the Data Time Configuration table is filled with the time configuration of the selected data and can be used in order to change the time configuration of the selected data Any change within the Data Time Configuration table is taken over by the Minimum Time Time Interval and Maximum Time cells of the Included Data table immediately The data names must be unique among all enabled rows when the user wants to save the Loading Profile The according check is done before the actual saving is started Name New data can be added to the Included Data table either via Drag amp Drop from the online or offline data section of the MDS Explorer or through typing of its name into the edit box directly English Release 2012 09 31 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Loading Mode Loading Mode Description Each Value In this loading mode each value from the offline data file of a data is put into the according buffer of the data Changes only In this loading mode a value from the offline data file of a data is put into the according buffer of the data only in case the difference in between the value from the offline data file and the last value from the buffer is bigger than the specified hysteresis Changes and Interval In this loading mode a value from the offline data file of a data is put into the according buffer of the data in case the difference in between the value from the
16. its storage directory multiple Stor age Profiles with matching file names can be stored in different Storage Profile directories Dragging of a Storage Profile into the Storage System workspace opens the Storage Profile Editor for the dragged Storage Profile In case a Storage Profile Directory Branch or any of its sub branches contains a suspended Storage Profile the icon of the Storage Profile Directory Branch shows an according overlay When there is no suspended Stor age Profile but there is at least one started Storage Profile the icon of the Storage Profile Directory Branch shows an according overlay also The following specific context menu items are provided Context Menu Item Description New Storage Profile gt opens a Storage Profile Editor of the chosen type within the Storage System workspace cre ates a new Storage Profile and initializes it with default values Edit opens a new Storage Profile Editor for the chosen file within the Storage System workspace Cut cuts the currently selected items Copy copies the currently selected items Paste pastes currently copied cut items Delete deletes the selected items from the disk Rename allows to rename the selected item directly within the STS Explorer New Directory opens the Add Directory dialog and creates a new directory afterwards Start starts the currently selected items Restart restarts 7 stops and starts th
17. new name has been entered into the Name field another new empty row is added to the Data table automatically Status The status of each data is determined by the SPE Binary T001 automatically In case the specified data is pre sent as online data at the moment Currently available is displayed Contrary Currently not available is dis played in case the specified data is not present as online data at the moment English Release 2012 09 24 44 SIPLUS CMS X Tools User Manual 07 Storage System Storage Mode SIPLUS CMS Storage Mode Description Each Value In this storage mode each value from the ring buffer of a data is put into the according file Changes only In this storage mode a value from the ring buffer of a data is put into the according file only in case the difference in between the value from the ring buffer and the last value from the file is bigger than the specified hysteresis Changes and Interval In this storage mode a value from the ring buffer of a data is put into the according file in case the difference in between the value from the ring buffer and the last value from the file is bigger than the specified hysteresis In addition the last known value from the ring buffer is put into the file each amount of time which is specified as interval Interval only In this storage mode a value from the ring buffer of a data is never put into the according file di rectly
18. offline data file and the last value from the buffer is bigger than the specified hysteresis In addition the last known value from the offline data file is put into the buffer each amount of time which is specified as interval Interval only In this loading mode a value from the offline data file of a data is never put into the according buffer of the data directly Instead the last known value from the offline data file is put into the buffer each amount of time which is specified as interval Minimum Time In case the time input mode is Minimum Time and Time Interval or Minimum Time and Maximum Time the Minimum Time cell contains the configured minimum time Time Interval In case the time input mode is Minimum Time and Time Interval or Time Interval and Maximum Time the Time Interval cell contains the configured time interval Maximum Time In case the time input mode is Minimum Time and Maximum Time or Time Interval and Maximum Time the Maximum Time cell contains the configured maximum time 2 3 3 6 Data Time Configuration Table The Data Time Configuration table contains the time configuration of the data which is currently being selected within the Included Data table Parameter Description Time Input Mode allows to switch between the available time input modes Time Domain allows to switch between the available time domains Minimum Time Format allows to switch
19. this export mode a value from the selected offline data files is being exported only in case the difference in between the value from the offline data files and the last value which has been ex ported is bigger than the specified hysteresis Changes and Interval In this export mode a value from the selected offline data files is being exported in case the dif ference in between the value from the offline data files and the last value which has been exported is bigger than the specified hysteresis In addition the last known value from the offline data files is being exported each amount of time which is specified as interval Interval only In this export mode a value from the selected offline data files never is being exported directly Instead the last known value from the offline data files is being exported each amount of time which is specified as interval English Release 2012 09 42144 SIPLUS CMS X Tools User Manual 07 Storage System Export Parameter SIPLUS CMS Export Parameter Description N A This export parameter is relevant for the storage mode Each Value only and is being applied auto matically in case this storage mode is being chosen Hysteresis This export parameter allows specifying via edit box the hysteresis for to be stored values and is being applied automatically in case the storage mode Changes Only is being chosen Hysteresis and Interval These export param
20. values English Release 2012 09 10 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 1 6 Loading Profile Editors Branch The one and only Loading Profile Editors Branch provides all of the Loading Profile Editors which are avail able within the Storage System The tree of shown Loading Profile Editors is updated automatically when ever an editor file at the local disk is added removed modified 2 1 7 Loading Profile Editor Branch Each Loading Profile Editor Branch represents one available Loading Profile Editor Dragging of a Loading Profile Editor Branch into the Storage System workspace opens an empty editor of the dragged type After the editor has been opened any of the present files of correct type can be dragged into it for visualization and or editing The following specific context menu items are provided Context Menu Item Description Open opens an empty Loading Profile Editor of the chosen type within the Storage System work space New Loading Profile gt opens a Loading Profile Editor of the chosen type within the Storage System workspace cre ates a new Loading Profile and initializes it with default values 2 1 8 Offline Data Loaders Branch The one and only Offline Data Loaders Branch provides all of the Offline Data Loaders which are available within the Storage System The tree of shown Offline Data Loaders is updated automatically whenever an editor file at the local
21. Company Name contains the company name Author Name contains the author name Target Name All of the information about the Target Name and Storage Path is set up within the Save As dialog English Release 2012 09 27144 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 3 2 3 Menu Bar Menu Button Description New This button creates a new empty Loading Profile and initializes the Loading Profile Settings table with the default values for new Loading Profiles In case there is a Loading Profile opened already it is closed automatically before the new one is being created Open This button opens the Open dialog where the user is able to select the file which shall be opened Save This button saves the currently opened Loading Profile to the currently known storage location In case the storage location has not been defined yet the Save As dialog is popping up automati cally and the user is able to select the desired storage location Save As This button opens the Save As dialog where the user is able to select the desired storage loca tion Close This button closes the editor In case the currently opened Loading Profile is not saved the editor asks the user whether the Loading Profile shall be saved before it is closed English Release 2012 09 28 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 3 3 LPE Standard T001 2 3 3 1 O
22. SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS SIEMENS Preface 1 Storage System 2 Contact Information 3 SIPLUS CMS SIPLUS CMS X Tools User Manual 07 Storage System English Release 2012 09 English Release 2012 09 1 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Safety Guidelines This document contains notices which you should observe to ensure your own personal safety as well as to avoid property damage The notices referring to your personal safety are highlighted in the manual by a safety alert symbol notices referring to property damage only have no safety alert symbol Danger Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution Used with the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in minor or mod erate injury gt d Notice Used without the safety alert symbol indicates a potential situation which if not avoided may result in an undesirable result or state When several danger levels apply the notices of the highest level lower number are always displayed If a notice refers to personal damages with the safety alert symbol then another notice may be added warning of property damage Qualified Perso
23. anch e Libraries Branch e Storage Process Modules Branch e Storage Process Module Branch 2 1 2 Main Branch The one and only Main Branch provides all of the other items of the STS Explorer It can be expanded and collapsed in order to show or hide its sub items 2 1 3 Editors Branch The one and only Editors Branch provides all of the editors which are available within the Storage System 2 1 4 Storage Profile Editors Branch The one and only Storage Profile Editors Branch provides all of the Storage Profile Editors which are available within the Storage System The tree of shown Storage Profile Editors is updated automatically whenever an editor file at the local disk is added removed modified 2 1 5 Storage Profile Editor Branch Each Storage Profile Editor Branch represents one available Storage Profile Editor Dragging of a Storage Profile Editor Branch into the Storage System workspace opens an empty editor of the dragged type After the editor has been opened any of the present files of correct type can be dragged into it for visualization and or editing The following specific context menu items are provided Context Menu Item Description Open opens an empty Storage Profile Editor of the chosen type within the Storage System work space New Storage Profile gt opens a Storage Profile Editor of the chosen type within the Storage System workspace cre ates a new Storage Profile and initializes it with default
24. ath Backslash Storage Profile Name lt Remove Click here in order to add another user defined element Add Element Remove Element English Release 2012 09 Move up Move down Restore Defaults Set as Standard Cancel Figure 3 Example of a Path Configuration Dialog 25 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 2 3 14 2 Path Configuration The Path Configuration list at the right side of this dialog contains the template for the to be created storage path Elements from the Elements list can be added after the hard coded elements at the top of the Path Con figuration list via the Add gt button and via the context menu of the Elements list Via the Move up and Move down buttons the position of elements can be changed within the Path Configuration list The Remove button as well as the Del keybord key and the context menu of the Path Configuration list can be used in order re move elements from the Path Configuration list In addition user defined elements with a static name can be added to the Elements list From there they can be used like any of the standard elements The Set as Standard button from the menu bar enables the current path configuration as default value for new Storage Profiles Restore Defaults resets the path configuration of the current Storage Profile to the default val ues Any element from the Elements list can be added zero one or multiple times to t
25. controls are provided by the Storage Profile Editors Depending to the Storage Profile Editor one or more parts may not be supported because they are not needed and one or more parts may be present in addi tion to the following ones because they are necessary e Storage Profile Settings Table e Menu Bar 2 2 2 2 Storage Profile Settings Table The Storage Profile Settings table contains all of the profile dependent settings which can be configured within a Storage Profile Parameter Description Target Name contains the name of the target to which the Storage Profile is stored Storage Path contains the path to which the Storage Profile is stored absolute or symbolic path Creation Date contains the creation date of the Storage Profile Modification Date contains the last modification date of the Storage Profile Profile Description contains the description of the Storage Profile Company Name contains the company name Author Name contains the author name Target Name All of the information about the Target Name and Storage Path is set up within the Save As dialog English Release 2012 09 14 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 2 2 3 Menu Bar Menu Button Description New This button creates a new empty Storage Profile and initializes the Storage Profile Settings table with the default values for new Storage Profiles In case there is
26. d Loading Profile The following specific context menu items are provided Context Menu Item Description New Loading Profile gt opens a Loading Profile Editor of the chosen type within the Storage System workspace cre ates a new Loading Profile and initializes it with default values Edit opens a new Loading Profile Editor for the chosen file within the Storage System workspace Cut cuts the currently selected items Copy copies the currently selected items Paste pastes currently copied cut items Delete deletes the selected items from the disk Rename allows to rename the selected item directly within the STS Explorer New Directory opens the Add Directory dialog and creates a new directory afterwards 2 1 16 Libraries Branch The Libraries Branch of each connected X Tools Server provides all of the libraries which are available for the Storage System 2 1 17 Storage Process Modules Branch The Storage Process Modules Branch of each connected X Tools Server provides all of the Storage Process Modules which are available for the Storage System The tree of shown Storage Process Modules is up dated automatically whenever a Storage Process Module at the disk is added removed modified English Release 2012 09 13 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 1 18 Storage Process Module Branch Each Storage Process Module Branch represents one available Storage Process Mod
27. disk is added removed modified 2 1 9 Offline Data Loader Branch Each Offline Data Loader Branch represents one available Offline Data Loader Dragging of an Offline Data Loader Branch into the Storage System workspace opens an empty editor of the dragged type After the editor has been opened any of the present X Tools Servers can be dragged into it in order to examine and load its present offline data The following specific context menu item is provided Context Menu Item Description Open gt opens an Offline Data Loader of the chosen type within the Storage System workspace and initializes it with default values 2 1 10 Servers Branch The one and only Servers Branch provides all of the X Tools Servers which are connected at the moment The tree of shown X Tools Servers is updated automatically whenever an X Tools Server is attached or detached 2 1 11 Server Branch Each Server Branch represents one of the currently connected X Tools Servers 2 1 12 Files Branch The Files Branch of each connected X Tools Server provides all of the files which are available within the Storage System The following specific context menu item is provided Context Menu Item Description Add Location opens the Add Location dialog and adds a new Configuration File location afterwards English Release 2012 09 11 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 1 13 File Location Bra
28. duration value Threshold Value contains the threshold value Lower Limit contains the lower limit of the interval Upper Limit contains the upper limit of the interval Hysteresis Value contains the hysteresis value Timer Interval Format contains the timer interval format Timer Interval Value contains the timer interval value Date contains the start date Time contains the start time Event Type Event Type Description Manually In case of this event type the actual storing of data is started immediately when the Storage Pro file is being started by Data In case of this event type the actual storing of data is started as soon as the specified data trigger condition has elapsed by Timer In case of this event type the actual storing of data is started as soon as the specified timer value has elapsed by Date and Time In case of this event type the actual storing of data is started as soon as the specified date and time has been reached In case the Storage Profile is being started after the specified start date and time it starts to store data and to create offline data files immediately Trigger Mode Trigger Mode Description Once In this trigger mode the start trigger is starting the storage only once Thus the Storage Profile is stopped completely when the stop condition has been reached after the first start Repeating In this trig
29. e from the buffer is bigger than the specified hysteresis In addition the last known value from the offline data file is put into the buffer each amount of time which is specified as interval Interval only In this loading mode a value from the offline data file of a data is never put into the according buffer of the data directly Instead the last known value from the offline data file is put into the buffer each amount of time which is specified as interval English Release 2012 09 39 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Time Input Mode Time Input Mode Description Default In this time input mode the ODL Standard T001 uses the specified values from the provided Loading Profile in order to determine the period of the data which shall be loaded from the se lected offline data files In case there is no Loading Profile provided or in case it does not contain information about the to be used minimum and maximum times all selected offline data files are loaded from their beginning until their end Minimum Time and Time Interval In this time input mode the ODL Standard T001 uses the specified Minimum Time Value and Time Interval Value parameters in order to determine the period of the data which shall be loaded from the selected offline data files Minimum Time and Maximum Time In this time input mode the ODL Standard T001 uses the specified Minimum Time Value and Maxim
30. e currently selected items Pause pauses the currently selected items Continue continues the currently selected items Stop stops the currently selected items English Release 2012 09 12 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS The following icons are provided and indicate the current status of each Storage Profile Icon Description B stopped The Storage Profile is stopped and does not perform any operations B started The Storage Profile is started and performs the specified storing The resulting data is stored to the disk and can be accessed via the Offline Data Loader E paused When the Storage Profile is paused it closes its current offline data files and does not perform any further storing until it is being continued B suspended The Storage Profile is suspended because it has detected an error condition e g because the input data became unavailable or because there is no more space available at the storage loca tion The Storage Profile will resume after the error condition has been solved While a Storage Profile is suspended a possible configured clean up is being continued without interruption and all of the current offline data files are being closed In case the Storage Profile is suspended and its according Storage Profile File at the disk is being updated the updated Storage Profile File is being loaded and the Storage Profile uses the up dated configuration f
31. ertain functionalities The following major branches are provided by the Offline Data Files tree e Server Branch e File Location Branch e Offline Data Directory Branch 2 4 2 4 2 Server Branch The one and only Server Branch provides all of the offline data files which are available at the X Tools Server The following specific context menu item is provided Context Menu Item Description Add Location opens the Add Location dialog and adds a new offline data file location afterwards 2 4 2 4 3 File Location Branch Each File Location Branch provides all of the offline data files and directories which are available from the direc tory to which the offline data file location points The following specific context menu item is provided Context Menu Item Description Remove Location removes the chosen file location 2 4 2 4 4 Offline Data Directory Branch Each Offline Data Directory Branch provides all of the offline data directories and offline data files which are available from the directory to which it points The tree of shown offline data directories and offline data files is updated automatically whenever an offline data directory or offline data file at the disk is added deleted modified The following specific context menu items are provided Context Menu Item Description Append appends the data of the selected items to the already present offline
32. eters allow to specify via edit box the hysteresis and the amount of time for the to be stored values and are being applied automatically in case the storage mode Changes and Interval is being chosen Interval This export parameter allows specifying via edit box the amount of the time for to be stored values and is being applied automatically in case the storage mode Interval Only is being chosen Time Input Mode Time Input Mode Description Default In this time input mode the full available time interval of the selected offline data files s being exported Minimum Time and Time Interval In this time input mode the time interval which is specified via the Minimum Time Value and Time Interval Value parameters is being exported Minimum Time and Maximum Time In this time input mode the time interval which is specified via the Minimum Time Value and Maximum Time Value parameters is being exported Time Interval and Maximum Time In this time input mode the time interval which is specified via the Time Interval Value and Maxi mum Time Value parameters is being exported Time Domains Time Domain Description Absolute Times When the time domain is set to Absolute Times the Minimum Time Value and Maximum Time Value rows expect the user input as absolute times Relative Times When the time domain is set to Relative Times the Minimum Time Value and Maximum Time
33. etween the available modes for the parallel storage Time Domain Time Domain Description Online Data with absolute Time the Storage Profile stores the online data according to the names which are specified via the Data stamps table Offline Data with absolute Time the Storage Profile stores the offline data with absolute names according to the names which are stamps specified via the Data table Offline Data with relative Timestamps the Storage Profile stores the offline data with relative names according to the names which are specified via the Data table In case a data with the specified name and chosen time domain is not present the Storage Profile creates empty files at the disk for the according data English Release 2012 09 16 44 SIPLUS CMS X Tools User Manual 07 Storage System Parallel Storage SIPLUS CMS Parallel Storage Description Do not allow parallel Storage in case a start event occurs when a storing is going on already and no matching stop event took place yet this other start event is ignored in case a post trigger time is configured and another start event occurs during the post trigger time the post trigger time is cancelled and the storing of the offline data file continues as if no stop event would have occurred at all Start a parallel Storage whenever another Start Event occurs whenever a start event occurs it starts another parallel storage of all data w
34. functionality which is provided by the Device Management System e SIPLUS CMS X Tools User Manual 05 Monitoring System o provides detailed information about the functionality which is provided by the Monitoring System e SIPLUS CMS X Tools User Manual 06 Analyzing System o provides detailed information about the functionality which is provided by the Analyzing System e SIPLUS CMS X Tools Release Notes o provides additional information about the released version of SIPLUS CMS X Tools e SIPLUS CMS X Tools Change Log o provides an overview about the changes which have been introduced with the current version of SIPLUS CMS X Tools 1 2 Validity of this Document This document is valid for the following software e SIPLUS CMS X Tools Demo V 03 05 e SIPLUS CMS X Tools Standard V 03 05 e SIPLUS CMS X Tools Professional V 03 05 During the following pages these software packages will be referred to by the term X Tools 1 3 Audience This document is intended for personnel involved in the commissioning and using of the software e X Tools English Release 2012 09 7144 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 1 4 The fo English Notations llowing notations are used within this document bold italic text is being used for the main executables of X Tools o examples X Tools Client X Tools Server bold text is being used for the software modules of X Tools o examples Main Management System De
35. g types into the mem ory buffers of the X Tools Server e X Tools Offline Data Files sdf xts e CMS2000 Database Files cmsdb e WAVE Files wav e CSV Files csv The following screenshot shows an example of an ODL Standard T001 YOURSERVER ODL Standard T001 o NE Z Offline File Locations CMS2000 Date Structure Offline Data Files gH YOURSERVER H Offline Files Offline Files CS 3 2 Example Offline Files sdf xts a ION Analoglnput T001 fg ION Binarylnput TOOT fg Order Analysis gy Rectangle 5 Log Entries Apply Cancel Loading Figure 6 Example of an ODL Standard T001 English Release 2012 09 34 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Each control of the ODL Standard T001 has a defined task and provides certain functionalities The following major controls are provided by the ODL Standard T001 Offline File Locations Table CMS2000 Date Structure Table Offline Data Files Tree Log Entries Table Menu Bar Dropping of Items Advanced Append Dialog Advanced Overwrite Dialog Advanced Export Dialog 2 4 2 2 Offline File Locations Table The Offline File Locations table contains all of the currently defined offline file locations Parameter Description No contains the row number Symbolic Name contains the symbolic name of the location Path contains the path to the location at its target server Location Type
36. ger mode the Storage Profile is continuing to trigger after each stop condition and may restart the storing infinite times Furthermore this trigger mode supports the parallel storage of multiple trigger events simultaneously in case the post trigger is turned on and the according post trigger option is enabled Trigger Data Name The desired trigger data either can be set through Drag amp Drop from the MDS Explorer or through typing of its name by hand English Release 2012 09 19 44 SIPLUS CMS X Tools User Manual 07 Storage System Trigger Data Type SIPLUS CMS The type of the trigger data is important for the selection of the Trigger Type later In case of Drag amp Drop of the desired data from the MDS Explorer the Trigger Data Type is set automatically However the user is free to change it at any times In case the Storage Profile is started and the specified type of the current trigger data does not match the type of the data within the system the Storage Profile is put into suspended state until the types match Trigger Type Trigger Type Description Threshold In case of this trigger type the start trigger is waiting until the specified threshold is reached Interval In case of this trigger type the start trigger is waiting until the specified interval is reached Threshold Type Threshold Type Description Rising Edge In case of this threshold type the start trigge
37. glnput T001 CHO ION Analoglnput T001 CHOS Drag amp drop the data which shall be stored from the MDS Explorer Currently available Currently available Currently available Currently available Currently available Currently available Currently available Currently available lt lt lt lt lt lt lt lt English Release 2012 09 Figure 2 Example of a SPE Binary T001 15 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Each control ofthe SPE Binary T001 has a defined task and provides certain functionalities The following ma jor controls are provided by the SPE Binary T001 e Storage Profile Settings Table e Storage Profile Parameters Table e Path and File Name Configuration Table e File Splitting Table e Start Event Table e Stop Event Table e Pre Trigger Table e Post Trigger Table e Disk Clean Up Table e Disk Limitation Table e Data Table e Menu Bar e Path Configuration Dialog e File Name Configuration Dialog e Dropping of Items 2 2 3 2 Storage Profile Settings Table The standard Storage Profile Settings table is being used by the SPE Binary T001 see point 2 2 2 2 2 2 3 3 Storage Profile Parameters Table The Storage Profile Parameters table contains the additional parameters of the currently opened Storage Pro file Row Description Time Domain allows to choose the time domain on which the Storage Profile shall operate Parallel Storage allows to switch b
38. havior of the Storage Profile in case another start event occurs during the post trigger time 2 2 3 10 Disk Clean Up Table The Disk Clean Up table contains all of the settings which are relevant for the disk clean up Depending to the configurations which are chosen within the Disk Clean Up table the according columns from the table below are being used and not all columns may be visible simultaneously Column Description No contains the row number Clean Up Type contains the clean up type Clean Up Interval Format contains the clean up interval format Clean Up Interval Value contains the clean up interval value Memory Format contains the memory format Memory Value contains the memory value Clean Up Type Clean Up Type Description Do not perform Clean Up In case of this clean up type the Storage Profile does not perform any file clean up Delete old Files In case of this clean up type the Storage Profile deletes all files which have been created longer ago than the specified interval Limit used Memory In case of this clean up type the Storage Profile deletes its oldest files in case all of its files to gether need more than the specified maximal amount of memory Assure remaining Memory In case of this clean up type the Storage Profile deletes its oldest files in case the storage loca tion has less than the specified amount of memory
39. he Path Configuration list 2 2 3 15 File Name Configuration Dialog 2 2 3 15 1 Overview The following screenshot shows an example of a File Name Configuration dialog File Name Configuration Data Name Add gt lt Remove Click here in order to add another user defined element Add Element Remove Element Move up Move down Restore Defaults Set as Standard Cancel Figure 4 Example of a File Name Configuration Dialog 2 2 3 15 2 File Name Configuration The File Name Configuration list at the right side of this dialog contains the template for the to be created file names Elements from the Elements list can be added to the File Name Configuration list via the Add gt button and via the context menu of the Elements list Via the Move up and Move down buttons the position of ele ments can be changed within the File Name Configuration list The Remove button as well as the Del key bord key and the context menu of the File Name Configuration list can be used in order remove elements from the File Name Configuration list In addition user defined elements with a static name can be added to the Elements list From there they can be used like any of the standard elements The Set as Standard button from the menu bar enables the current file name configuration as default value for new Storage Profiles Restore Defaults resets the file name configuration of the current Storage Profile to the default value
40. hen offline data is being loaded Minimum Time and Maximum Time In this time input mode the specified Minimum Time Value and Maximum Time Value parameters are used when offline data is being loaded Time Interval and Maximum Time In this time input mode the specified Time Interval Value and Maximum Time Value parameters are used when offline data is being loaded English Release 2012 09 30 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Time Domain Time Domain Description Absolute Times When the time domain is set to Absolute Times the Minimum Time Value and Maximum Time Value rows expect the user input as absolute times Relative Times When the time domain is set to Relative Times the Minimum Time Value and Maximum Time Value rows expect the user input as relative times 2 3 3 5 Included Data Table The Included Data table contains all of the data which shall be included when offline data is being loaded Column Description No contains the row number Enabled specifies whether the configuration within this row shall be considered when offline data is being loaded or not Name contains the name of the data Loading Mode contains the loading mode of the data Loading Parameters contains the loading parameters Minimum Time contains the configured minimum time Time Interval contains the configured time interval Max
41. hich is configured for this Storage Profile in case the stop event is by data the following mechanisms apply e the Minimal Start to Stop Interval Format within the Stop Event table can be set to Auto matic in this case the Storage Profile determines the minimal start to stop interval auto matically o incase Automatic is chosen the Storage Profile must be started before the to be monitored process starts to run in case the Storage Profile would be started while the to be monitored process is running already it is unable to assign the occurring start and stop events properly o incase the start of the Storage Profile could happen at a moment where the to be monitored process is running already the minimal start to stop interval must be config ured manually e incasea minimal start to stop interval is provided manually all stop events which are be fore start event time minimal start to stop interval are ignored Start a parallel Storage only in case another Start Event occurs during the Post Trigger Time in case a start event occurs when a storing is going on already and no matching stop event took place yet this other start event is ignored in case the stop event took place already and the new start event occurs before the end of the post trigger time it starts another parallel storage of all data which is configured for this Storage Profile 2 2 3 4 Path and File Name Configuration Table The Subdi
42. imum Time contains the configured maximum time The user is able to highlight a complete row or multiple rows and to delete them via the context menu Re move context menu item and or via the keyboard Del key A highlighted row or multiple rows can be copied cut pasted to another row of the Included Data table of the current or any other Loading Profile Editor via mechanisms of the context menu Copy Cut and Paste context menu items and or via the keyboard lt Ctrl C gt lt Ctrl X gt and lt Ctrl V gt keys Any data which is copied from the Included Data table of a Loading Profile can be copied to the Included Data and Excluded Data tables of other Loading Profiles as well as to the Data table of Storage Profiles The last row of the Included Data table always is an empty row except the Name cell see below and therefore it allows the user to add a data by typing another name into the Name field of this last row All other cells of the last row are empty and disabled as long as the Name field is empty Whenever a new name has been entered into the Name field all other columns are set to their default values and another new empty row is added to the Included Data table automatically Via Drag amp Drop any existing data can be dropped onto the Included Data table Any dropped data is added to the Included Data table automatically like if its name would have entered manually Whenever a row of the Included Data table
43. ine data is being loaded Use individual Times When the time filter is set to Use individual Times the time configurations from the Included Data table are used when offline data is being loaded and the time configurations from the Default Time Configuration table are ignored when offline data is being loaded 2 3 3 4 Default Time Configuration Table The Default Time Configuration table contains the default time configuration which can be configured within a Loading Profile Parameter Description Time Input Mode allows to switch between the available time input modes Time Domain allows to switch between the available time domains Minimum Time Format allows to switch between the available input formats for the minimum time Minimum Time Value allows to enter the minimum time of the data which shall be loaded Time Interval Format allows to switch between the available input formats of the time interval Time Interval Value allows to enter the time interval of the data which shall be loaded Maximum Time Format allows to switch between the available input formats for the maximum time Maximum Time Value allows to enter the maximum time of the data which shall be loaded Time Input Mode Time Input Mode Description Minimum Time and Time Interval In this time input mode the specified Minimum Time Value and Time Interval Value parameters are used w
44. interval type the start trigger is waiting until a value outside the interval is detected English Release 2012 09 20 44 SIPLUS CMS X Tools User Manual 07 Storage System 2 2 3 7 SIPLUS CMS Stop Event Table The Stop Event table contains all of the settings which are relevant for the stop event Depending to the configu rations which are chosen within the Stop Event table the according columns from the table below are being used and not all columns may be visible simultaneously Column Description No contains the row number Event Type contains the stop event type Trigger Data Name contains the name of the data onto which shall be triggered Trigger Data Type contains the data type of the data onto which shall be triggered Minimal Start to Stop Interval Format contains the minimal start to stop interval format Minimal Start to Stop Interval Value contains the minimal start to stop interval value Trigger Type contains the stop trigger type Threshold Type contains the stop trigger threshold type Interval Type contains the stop trigger interval type Bounce Duration Format contains the bounce duration format Bounce Duration Value contains the bounce duration value Threshold Value contains the threshold value Lower Limit contains the lower limit of the interval Upper Limit contains the upper limit of the interval Hys
45. l 07 Storage System SIPLUS CMS 2 4 2 8 2 Location Parameters Table The Location Parameters table contains the parameters of the location which shall be added Parameter Description Symbolic Name contains the symbolic name of the location Path contains the path of the location at the disk Location Type contains the desired target file type of the location Symbolic Name This is the name of the location which is shown by X Tools At different places it can be used in order to refer ence to an already existing location Location Type Location Type Description X Tools Offline Data Files sdf xts the new location shall show only offline data files which have been stored by X Tools CMS2000 Database Files cmsdb the new location shall show only offline data files which match the CMS2000 database format WAVE Files wav the new location shall show only offline data files which match the WAVE format CSV Files csv the new location shall show only offline data files which match the CSV format 2 4 2 9 Advanced Append Dialog 2 4 2 9 1 Overview The following screenshot shows an example of an Advanced Append dialog Appending Parameters No Parameter UL Vaue UUUUUUUUUUUUUUUU 02 Loading Mode 04 Time Input Mode 05 Time Domain 06 Minimum Time Format Minimum Time Value og Time Interval Format 09 Time Interval Value Ma
46. l format Splitting Interval Value contains the splitting interval value Splitting Mode Splitting Mode Description Off In this splitting mode all values of one data are being stored into one file which lasts from the start of the Storage Profile until its stop Time based In this splitting mode a new directory and data file is being created each amount of time which is specified as splitting interval English Release 2012 09 18 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 2 3 6 Start Event Table The Start Event table contains all of the settings which are relevant for the start event Depending to the con figurations which are chosen within the Start Event table the according columns from the table below are being used and not all columns may be visible simultaneously Column Description No contains the row number Event Type contains the start event type Trigger Mode contains the start trigger mode Trigger Data Name contains the name of the data onto which shall be triggered Trigger Data Type contains the data type of the data onto which shall be triggered Trigger Type contains the start trigger type Threshold Type contains the start trigger threshold type Interval Type contains the start trigger interval type Bounce Duration Format contains the bounce duration format Bounce Duration Value contains the bounce
47. le ee ne rennt td 23 Disk Glean Up Tabler 4u 48er animal 23 Disk Limitation Table irm A etti ced 24 Data Table E 24 Menu Bara ede NRI VL EE 25 Path Configuration Dialog 25 eM E 25 Ce ee UI LEE 26 File Name Configuration Dialog 26 EE 26 File Name Configuration emm rr 26 Dropping ef Items oi re nct eto ted ann 27 Loading Profile Editors en rete ee teer nee ae ne nn 27 LO LS RU uten dic ien im x een nhe 27 Common Controls aaraa sa ER Lee a teeth tege rein 27 OVEIVIS REIS 27 Loading Profile Settings Table 27 Men Bar i nep uet onm nennen nitate utet 28 ERBE Standard T001 i ntm dett et bae ft GU fert 29 Gy ELI 29 Loading Profile Settings Table 29 Loading Profile Parameters Table sssssssssseenee eene nennen 30 Default Time Configuration Table emen 30 leie e RECETTE 31 Data Time Configuration Table deme tee eek 32 Excluded Data Table edite bled deed ceti ebd d Leid e dede ed dae oe 33 Men Bar ict lodos Dione nitens nice nimii 33 Blees ke fe ne mie tuni eund 33 Offline Data LO ad vii RE eH tere tro n atte E dee 34 OVOIVIQW u i etel Mn e LO M e lh be ers 34 ODL Standard TOO Vivanco ie 34 OVOLVIGW ee ee t dio e ete be eite P dt ifs 34 Offline File Locations Table 35 CMS2000 Date Structure Table un een 35 Offline Data Files Tree odii cade eere inde dee had nee 36 eU LEY 36 Server BIANCH 2 hot dim tamtn t
48. left English Release 2012 09 23 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 2 3 11 Disk Limitation Table The Disk Limitation table contains all of the settings which are relevant for the disk limitation Depending to the configurations which are chosen within the Disk Limitation table the according columns from the table below are being used and not all columns may be visible simultaneously Column Description No contains the row number Limitation Type contains the limitation type Memory Format contains the memory format Memory Value contains the memory value Percentage contains the percentage Limitation Type Limitation Type Description Do not check a Limit In case of this limitation type the Storage Profile does not perform any file clean up Leave absolute Memory In case of this limitation type the Storage Profile is stopped in case the storage location has less than the specified amount of memory left Leave relative Memory In case of this limitation type the Storage Profile is stopped in case the storage location has less than the specified amount of memory left 2 2 3 12 Data Table The Data table contains all of the data which are to be stored Column Description No contains the row number Enabled specifies whether the data within this row shall be enabled during the start of the Storage Profile or not
49. lue allows to enter the maximum time of the of the data which shall be loaded Used Loading Profile In case the user enters the path to a valid Loading Profile into this control the ODL Standard T001 uses the specified settings from the Loading Profile and loads the data from the offline data files at the disk accordingly When no Loading Profile is being specified all of the currently selected offline data files are being loaded Loading Mode Loading Mode Description Default Each Value In this loading mode the ODL Standard T001 uses the specified values from the provided Load ing Profile in order to determine the values of the data which shall be loaded from the selected offline data files In case there is no Loading Profile provided all values of all selected offline data files are being loaded In this loading mode each value from the offline data file of a data is put into the according buffer of the data Changes only In this loading mode a value from the offline data file of a data is put into the according buffer of the data only in case the difference in between the value from the offline data file and the last value from the buffer is bigger than the specified hysteresis Changes and Interval In this loading mode a value from the offline data file of a data is put into the according buffer of the data in case the difference in between the value from the offline data file and the last valu
50. m dete 36 File Location Branch ed ee aa een eatin e pP re 36 Offline Data Directory Branch AA 36 L g Entries Table ru meneame Re 37 Menu Baf ur He et bts e aaa eer eM x td ete ngo e aru xd eap oer 37 Dropping of TTT 37 4144 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 4 2 8 Add Location Dialogi aet nit bti tete bue imer tien 37 2 4 2 8 1 OVER ada 37 2 4 2 8 2 Location Parameters Table euere een an 38 2 4 2 9 Advanced Append Dialog 38 2 4 2 9 1 OVA ed ee eene fee ic e Re Pee RC ERR E Res 38 2 4 2 9 2 Appending Parameters Table eene nennen 39 2 4 2 10 Advanced Overwrite Dialog ire RB Mn bM eoe uc Rude 40 2 4 2 10 1 O eg ee led te de etn ed ages e ned Ae te ed ia eee ee ete ed et edd ae 40 2 4 2 11 Advanced Export Dialog ssessseseee eene nennen nennen nn 41 2 4 2 11 1 O sites f Ero cre t siot ecc ced tii semi Lies 41 2 4 2 11 2 Exporting Parameters Table 41 3 Contact Information s iic od eR Rhenum dana enu 44 English Release 2012 09 5 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Table of Figures Figure 1 Figure 2 Figure 7 Figure 7 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 English Example of a STS Explorer nu een 9 Example ofa SPE Binary TOO Ti occitano 15 Example of a Path Configuration Dialog sess meer ener nnns 25 Example of a File Name Configuration Dialog 26
51. me cell see below and there fore it allows the user to add a data by typing another name into the Name field of this last row All other cells of the last row are empty and disabled as long as the Name field is empty Whenever a new name has been en tered into the Name field another new empty row is added to the Excluded Data table automatically Via Drag amp Drop any existing data can be dropped onto the Excluded Data table Any dropped data is added to the Excluded Data table automatically like if its name would have entered manually Name New data can be added to the Excluded Data table either via Drag amp Drop from the online or offline data section of the MDS Explorer or through typing of its name into the edit box directly As any data can not be excluded twice each entry within the Name column must be unique 2 3 3 8 Menu Bar The standard Menu Bar is being used by the LPE Standard T001 see point 2 3 2 3 2 3 3 9 Dropping of Items Dropped Item Description Loading Profile File Branches of type LPF Standard T001 opens the dropped Loading Profile Online Data Branches in case the LPE Standard T001 is not empty adds the dropped online data to the Included Data table or adds the dropped online data to the Excluded Data table Offline Data Branches in case the LPE Standard T001 is not empty adds the dropped offline data to the Included Data table or adds the dropped offline data to the Excluded Da
52. n case of this threshold type the stop trigger is waiting until a value which is bigger than the specified threshold is detected Value Threshold In case of this threshold type the stop trigger is waiting until a value which is lower than the speci fied threshold is detected Interval Type Interval Type Description Join Interval In case of this interval type the stop trigger is waiting until the specified interval is joined Leave Interval In case of this interval type the stop trigger is waiting until the specified interval is left Inside Interval In case of this interval type the stop trigger is waiting until a value inside the interval is detected Outside Interval In case of this interval type the stop trigger is waiting until a value outside the interval is detected 2 2 3 8 Pre Trigger Table The Pre Trigger table contains all of the settings which are relevant for the pre trigger Depending to the configu rations which are chosen within the Pre Trigger table the according columns from the table below are being used and not all columns may be visible simultaneously Column Description No contains the row number Pre Trigger Mode contains the pre trigger mode Duration Format contains the duration format Duration Value contains the duration value Pre Trigger Mode Pre Trigger Mode Description Off In case of thi
53. nch Each File Location Branch provides all ofthe Storage System specific files which are available from the direc tory to which the Configuration File location points The following specific context menu items are provided Context Menu Item Description Delete Location deletes the chosen file location from the hard disk Remove Location removes the chosen file location from X Tools but keeps it at the hard disk 2 1 14 Storage Profile Files Branch Each Storage Profile Files Branch provides all of the Storage Profiles which are available from the directory to which its Configuration File location points The tree of shown Storage Profiles is updated automatically when ever a Storage Profile at the disk is added deleted modified Drag amp Drop can be used in order to copy move Storage Profile directories and Storage Profile files The default Drag amp Drop operation within an X Tools Server is move but when the Ctrl key is pressed a copy opera tion is performed The default Drag amp Drop operation from one X Tools Server to another is copy but when the Shift key is pressed a move operation is performed Storage Profile directories and Storage Profile files can be copied moved within Storage Profile Files Branches either within one X Tools Server or over different X Tools Servers but they can not be copied moved to an other files branch As the unique name of each Storage Profile also includes
54. ng Profile Editors at all However the X Tools Server is responsible to maintain Loading Profile Files and therefore all Loading Profile reading and writing operations are performed via the X Tools Server 2 3 2 Common Controls 2 3 2 1 Overview As all Loading Profile Editors are built up in a similar way they share some common controls e g tables and the menu bar which are the same in all Loading Profile Editors Each control of a Loading Profile Editor has a defined task and provides certain functionalities The following major controls are provided by the Loading Profile Editors Depending to the Loading Profile Editor one or more parts may not be supported because they are not needed and one or more parts may be present in addi tion to the following ones because they are necessary e Loading Profile Settings Table e Menu Bar 2 3 2 2 Loading Profile Settings Table The Loading Profile Settings table contains all of the profile dependent settings which can be configured within a Loading Profile Parameter Description Target Name contains the name of the target to which the Loading Profile is stored Storage Path contains the path to which the Loading Profile is stored absolute or symbolic path Creation Date contains the creation date of the Loading Profile Modification Date contains the last modification date of the Loading Profile Profile Description contains the description of the Loading Profile
55. nnel The device system may only be set up and operated in conjunction with this documentation Only qualified personnel should be allowed to install and work on the equipment Qualified persons are defined as persons who are authorized to commission to earth and to tag cir cuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning only in connection with devices or components from other manufacturers approved or recommended by Siemens This prod uct can only function correctly and safely if it is transported stored set up and installed correctly and operated and main tained as recommended This device and its components may only be used for the applications described in the catalog or technical description and Trademarks All designations marked with amp are registered trademarks of Siemens AG Other designations in this documentation might be trademarks which if used by third parties for their purposes might infringe upon the rights of the proprietors Copyright Siemens AG 2012 All rights reserved Reproduction transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility model or design are reserved Disclaimer of Liability We have checked the contents of this document f
56. ols Server The last entry of the combo box is and opens the Add Location dialog when it is being chosen When a new storage location has been defined via the Add Location dialog it is added to the Storage Location combo box automatically and automatically becomes the currently selected one English Release 2012 09 17144 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS The actual directory names to which data is stored by the current Storage Profile are composed out of the fol lowing parts e absolute path of the chosen location e Storage Profile directory structure below its Storage Profile storage location like it is shown by the STS Explorer e Storage Profile name e directories and files according to the settings from the settings from the Path and File Name parameters File overwrite Mode File overwrite Mode Description Create a unique Directory Path in case the full path directory path file name of the to be stored file exists already the name of the last subdirectory of the directory path gets a postfix like 1 instead of 1 the first number which leads to a unique directory path is being used Create a unique File Name in case the full path directory path file name of the to be stored file exists already the name of the file gets a postfix like 1 instead of 1 the first number which leads to a unique file name is being used Overwrite the existing File in
57. or agreement with the hardware and software described Since deviations cannot be precluded entirely we cannot guarantee full agreement However the data in the manual are reviewed regularly and any necessary cor rections will be included in subsequent editions Suggestions for improvement are welcomed Siemens AG Industry Sector P O Box 4848 90327 Nuremberg Siemens AG 2012 Germany Technical data subject to change English Release 2012 09 2 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Table of Contents 1 Preta DM 7 1 1 Purpose of this Deene EES Maas EM die apre boten 7 1 2 Validity of this Doc rment e ae ar Lei 7 1 3 Audiences eit aaa 7 1 4 lee TR 8 2 Storage System amt p in E e api pe eim RE eimi bas 9 2 1 Storage System Exploter ek ec eet d tecta d se ee de od a pret gei rt deoa 9 2 1 1 EE 9 2 1 2 Mal BIAN EE 10 2 1 3 Editors Brarich E 10 2 1 4 Storage Profile Editors Branch 2i dese ge roe a NEU tb uolui bi 10 2 1 5 Storage Profile Editor Branche 10 2 1 6 Loading Profile Editors Branche 11 2 1 7 Loading Profile Editor Branche 11 2 1 8 Offline Data Loaders Branche 11 2 1 9 Offline Data Loader Branch AA 11 2 1 10 Servers Branch Si en dutem het ehe 11 2 1 11 Server Branch Her tudine uut qtd mtn 11 2 1 12 FIRS BANON e 11 2 1 13 File Location o oS 12 2 1 14 Storage Profile Files Branch A 12 2 1 15 Loading Profile Files Branche 13 2 1 16 Libraries
58. or its further processing a triggering The Storage Profile is triggering and does not perform storing yet As soon as the specified start event occurs the storing is being started 2 1 15 Loading Profile Files Branch Each Loading Profile Files Branch provides all of the Loading Profiles which are available from the directory to which its Configuration File location points The tree of shown Loading Profiles is updated automatically when ever a Loading Profile at the disk is added deleted modified Drag amp Drop can be used in order to copy move Loading Profile directories and Loading Profile files The default Drag amp Drop operation within an X Tools Server is move but when the Ctrl key is pressed a copy opera tion is performed The default Drag amp Drop operation from one X Tools Server to another is copy but when the Shift key is pressed a move operation is performed Loading Profile directories and Loading Profile files can be copied moved within Loading Profile Files Branches either within one X Tools Server or over different X Tools Servers but they can not be copied moved to an other files branch As the unique name of each Loading Profile also includes its storage directory multiple Load ing Profiles with matching file names can be stored in different Loading Profile directories Dragging of a Loading Profile into the Storage System workspace opens the Loading Profile Editor for the dragge
59. or the data can be chosen by selecting of an already defined storage location via the provided combo box which contains the symbolic names of all of the currently known root data locations of the source X Tools Server of the selected data The last entry of the combo box is and opens the Add Location dialog when it is being chosen When a new storage location has been defined via the Add Location dialog it is added to the Export Location combo box automatically and automatically becomes the currently selected one Export Path The Export Path contains the name of the used location as well as the following path of directories Export File Type Export File Type Description csv Comma separated Values When the export file type is set to csv Comma separated Values the selected offline data files are being exported to csv compatible files dat DIAdem Data Format When the export file type is set to dat DIAdem Data Format the selected offline data are being exported to dat compatible files Timestamp Format Timestamp Format Description ns When the timestamp format is set to ns timestamps are written into the exported file as ns since 1970 01 01 00 00 00 GMT in case of absolute timestamps or as ns since 000000 00 00 00 in case of relative timestamps Date Time ns GMT When the timestamp format is set to Date Time ns GMT timestamps are written into
60. ormation that is available from the STS Explorer The following screenshot shows an example of a STS Explorer STS Explorer gt Main BFP Editors Sg Storage Profile Editors Eb SPE Binary T001 E S Loading Profile Editors 7 29 Offline Data Loaders GC 88 Servers amp NjYOURSERVER E Files gt Default Location Beg Storage Profile Files LS Storage Profile 02 H Loading Profile Files SH Example Location Sen Storage Profile Files 3 Measurement Tasks 5 Example for an ION amp naloglnput TOUT 5 Sequence Control 01 5 Sequence Control 02 5 Sequence Control 03 5 Sequence Control 04 2 8 Loading Profile Files Sg Measurement Tasks 8 5 Example Loading Profile B Libraries S Storage Process Modules Be SPM Binary TO By SPM CMS2000 T001 5 SPM CSV T001 Y SPM wav T001 ee Figure 1 Example of a STS Explorer English Release 2012 09 9 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Each branch of the STS Explorer has a defined task and provides certain functionalities The following major branches are provided by the STS Explorer e Main Branch e Editors Branch e Storage Profile Editors Branch e Storage Profile Editor Branch e Loading Profile Editors Branch e Loading Profile Editor Branch e Offline Data Loaders Branch e Offline Data Loader Branch e Servers Branch e Server Branch e Files Branch e File Location Branch e Storage Profile Files Branch e Loading Profile Files Br
61. r is waiting until a rising edge is detected Falling Edge In case of this threshold type the start trigger is waiting until a falling edge is detected Value is O In case of this threshold type the start trigger is waiting until a value of O is detected Value is 1 In case of this threshold type the start trigger is waiting until a value of 1 is detected Rising Edge with Threshold In case of this threshold type the start trigger is waiting until a rising edge above the specified threshold is detected Falling Edge with Threshold In case of this threshold type the start trigger is waiting until a falling edge below the specified threshold is detected Value Threshold In case of this threshold type the start trigger is waiting until a value which is bigger than the specified threshold is detected Value Threshold In case of this threshold type the start trigger is waiting until a value which is lower than the speci fied threshold is detected Interval Type Interval Type Description Join Interval In case of this interval type the start trigger is waiting until the specified interval is joined Leave Interval In case of this interval type the start trigger is waiting until the specified interval is left Inside Interval In case of this interval type the start trigger is waiting until a value inside the interval is detected Outside Interval In case of this
62. rectory Creation table is used in order to specify the structure and presence of the date and time re lated directories which are created by the current Storage Profile when it is running The table contains two rows where the first row contains the cells according to the described columns and the second row contains a sample directory which would be the result of the current settings Row Description Storage Location allows to switch between the already defined storage locations and to define additional storage locations Path displays an example of the currently configured path and allows to change the path configuration via the Path Configuration dialog File Name displays an example of the currently configured file name and allows to change the file name con figuration via the File Name Configuration dialog File overwrite Mode allows to switch between the available file overwrite modes Storage ID 1 contains the name of the data whose value shall be used as Storage ID 1 Storage ID 2 contains the name of the data whose value shall be used as Storage ID 2 Storage ID 3 contains the name of the data whose value shall be used as Storage ID 3 Storage Location The desired storage location for the data can be chosen by selecting of an already defined storage location via the provided combo box which contains the symbolic names of all of the currently known root data locations of the specified target X To
63. s Any element from the Elements list can be added zero one or multiple times to the File Name Configuration list English Release 2012 09 26 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 2 3 16 Dropping of Items Dropped Item Description Storage Profile File Branches of type opens the dropped Storage Profile SPF Binary T001 Online Data Branches in case the creates a new Storage Profile initializes it with default values and adds the dropped online data to SPE Binary T001 is empty the Data table Online Data Branches in case the adds the dropped online data to the Data table or SPE Binary T001 is not empty inserts the dropped online data as start trigger data or inserts the dropped online data as stop trigger data 2 3 Loading Profile Editors 2 3 1 Overview Loading Profile Editors are used in order to edit Loading Profiles A Loading Profile contains all of the informa tion which is needed in order to specify which of the present data shall be loaded by an Offline Data Loader The detailed interactions in between Loading Profiles and Offline Data Loaders as well as the possible pa rameters for Loading Profiles are dependent to the used storage format and are discussed within the description of each Loading Profile Editor and Offline Data Loader Loading Profile Editors are known and accessed exclusively by the X Tools Client the X Tools Server has no knowledge about Loadi
64. s In case the Storage Profile is started and the specified type of the current trigger data does not match the type of the data within the system the Storage Profile is put into suspended state until the types match Minimal Start to Stop Interval See point 2 2 3 3 English Release 2012 09 21 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS Trigger Type Trigger Type Description Threshold In case of this trigger type the stop trigger is waiting until the specified threshold is reached Interval In case of this trigger type the stop trigger is waiting until the specified interval is reached Threshold Type Threshold Type Description Rising Edge In case of this threshold type the stop trigger is waiting until a rising edge is detected Falling Edge In case of this threshold type the stop trigger is waiting until a falling edge is detected Value is O In case of this threshold type the stop trigger is waiting until a value of O is detected Value is 1 In case of this threshold type the stop trigger is waiting until a value of 1 is detected Rising Edge with Threshold In case of this threshold type the stop trigger is waiting until a rising edge above the specified threshold is detected Falling Edge with Threshold In case of this threshold type the stop trigger is waiting until a falling edge below the specified threshold is detected Value Threshold I
65. s pre trigger mode the first value which is being stored to file matches the time of the start event without additional values from the time before the start event On In case of this pre trigger mode the first value which is being stored to file matches the time of the start event minus the specified duration English Release 2012 09 22 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 2 3 9 Post Trigger Table The Post Trigger table contains all of the settings which are relevant for the post trigger Depending to the con figurations which are chosen within the Post Trigger table the according columns from the table below are be ing used and not all columns may be visible simultaneously Column Description No contains the row number Post Trigger Mode contains the post trigger mode Duration Format contains the duration format Duration Value contains the duration value Post Trigger Mode Post Trigger Mode Description Off in case of this post trigger mode the last value which is being stored to file matches the time of the stop event without additional values from the time after the stop event On in case of this post trigger mode the last value which is being stored to file matches the time of the stop event plus the specified duration te chosen setting of the Parallel Storage parameter from the Storage Profile Parameters table describes the be
66. ta table English Release 2012 09 33 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 4 Offline Data Loaders 2 4 1 Overview Offline Data Loaders are used in order to load the data which has been stored by executed Storage Profiles from their storage location e g from the file system or from a database and back into the X Tools Server Offline Data Loaders do not create any Configuration Files but are used exclusively for loading of data from their storage locations For faster and more convenient loading of desired data Offline Data Loaders support to apply Loading Profiles during the loading operation The detailed interactions between Loading Profiles and Offline Data Loaders as well as the possible parameters for Loading Profiles are dependent to the used storage format and are dis cussed within the documentation of each Loading Profile Editor and each Offline Data Loader Offline Data Loaders are known and accessed exclusively by the X Tools Client the X Tools Server has no knowledge about Storage Data Editors at all However the X Tools Server and its Storage Process Mod ules are used by Offline Data Loaders for all loading operations which are specified by the user because Off line Data Loaders do not have any direct access to stored data at the X Tools Server 2 4 2 ODL Standard T001 2 4 2 1 Overview The ODL Standard T001 is used in order to load data from offline data files of the followin
67. teresis Value contains the hysteresis value Timer Interval Format contains the timer interval format Timer Interval Value contains the timer interval value Date contains the stop date Time contains the stop time Event Type Event Type Description Manually In case of this event type the actual storing of data is stopped when the Storage Profile is being stopped by Data In case of this event type the actual storing of data is stopped as soon as the specified data trig ger condition has elapsed by Timer In case of this event type the actual storing of data is stopped as soon as the specified timer value has elapsed by Date and Time In case of this event type the actual storing of data is stopped as soon as the specified date and time has been reached Immediately In case of this event type the actual storing of data is stopped at exactly the time of the start event In case a pre trigger and or a post trigger are defined the data from these times is stored Trigger Data Name The desired trigger data either can be set through Drag amp Drop from the MDS Explorer or through typing of its name by hand Trigger Data Type The type of the trigger data is important for the selection of the Trigger Type later In case of Drag amp Drop of the desired data from the MDS Explorer the Trigger Data Type is set automatically However the user is free to change it at any time
68. the exported file as date time and ns in GMT in case of absolute timestamps or as time and ns in case of relative timestamps Date Time ns Local Time When the timestamp format is set to Date Time ns Local Time timestamps are written into the exported file as date time and ns in local time in case of absolute timestamps or as time and ns in case of relative timestamps Decimal Precision Decimal Precision Description Automatic When the decimal precision is set to Automatic decimal values are written into the exported file with the maximal available accuracy of each value Thus the number of digits after the comma can vary in between the values within one line and in between the values of one data from line to line 0 3 6 9 or 12 When the decimal precision is set to 0 3 6 9 or 12 decimal values are written into the exported file with the specified number of digits Export Mode Export Mode Description Default In this export mode the ODL Standard T001 uses the specified values from the provided Loading Profile in order to determine the values of the data which shall be exported from the selected off line data files In case there is no Loading Profile provided all values of all selected offline data files are being exported Each Value In this export mode each value from the selected offline data files is being exported Changes only In
69. ule The following specific context menu items are provided Context Menu Item Description New Storage Profile opens a Storage Profile Editor of the chosen type within the Storage System workspace cre ates a new Storage Profile and initializes it with default values Load Offline Data opens a Offline Data Loader of the chosen type within the Storage System workspace and ini tializes it with default values 2 2 Storage Profile Editors 2 2 1 Overview Storage Profile Editors are used in order to edit Storage Profiles A Storage Profile contains all of the informa tion which is needed in order to start the storing of the defined data to the specified location Multiple Storage Profiles can be maintained and or executed at each X Tools Server simultaneously Storage Profile Editors are known and accessed exclusively by the X Tools Client the X Tools Server has no knowledge about Storage Profile Editors at all However the X Tools Server is responsible to maintain Storage Profile Files and therefore all Storage Profile reading and writing operations are performed via the X Tools Server 2 2 2 Common Controls 2 2 2 1 Overview As all Storage Profile Editors are built up in a similar way they share some common controls e g tables and the menu bar which are the same in all Storage Profile Editors Each control of a Storage Profile Editor has a defined task and provides certain functionalities The following major
70. um Time Value parameters in order to determine the period of the data which shall be loaded from the selected offline data files Time Interval and Maximum Time In this time input mode the ODL Standard T001 uses the specified Time Interval Value and Maxi mum Time Value parameters in order to determine the period of data which shall be loaded from the selected offline data files Time Domain Time Domain Description Absolute Times When the time domain is set to Absolute Times the Minimum Time Value and Maximum Time Value rows expect the user input as absolute times Relative Times When the time domain is set to Relative Times the Minimum Time Value and Maximum Time Value rows expect the user input as relative times 2 4 2 10 Advanced Overwrite Dialog 2 4 2 10 1 Overview The following screenshot shows an example of an Advanced Overwrite dialog Parameter Loading Mode Default Loading Parameters N Time Input Mode Default Time Domain N Minimum Time Format N Minimum Time Value N A Time Interval Format N Time Interval Value N A Maximum Time Format N A Maximum Time Yalue N A Figure 10 Example of an Advanced Overwrite Dialog The available configurations within the Advanced Overwrite dialog match the available configurations within the Advanced Append dialog see point 2 4 2 8 English Release 2012 09 40 44 SIPLUS CMS X Tools User Manual 07 Storage System
71. verview The LPE Standard T001 is used in order to visualize create and edit Loading Profiles of type Standard T001 Multiple editors of this type can be opened and used simultaneously The following screenshot shows an example of a LPE Standard T001 Loading Profile Settings Loading Profile Parameters Default Time Configuration cea EE KI pr Yalue Tm N A N A Changes only Hysteresis 1 000_ V Interval only Interval s 0 100 Changes and Interval Hysteresis 1 000 Interval s 0 100 M Each Value N A Each h Value f N A M Each Value N Iv Each Value N A r ION Analoginput T001 CHO1 Data Time Configuration Excluded Data No Enabled Name 1 TT Drag amp drop the data which shall be excluded from the MDS Explorer Figure 5 Example of a LPE Standard T001 Each control of the LPE Standard T001 has a defined task and provides certain functionalities The following major controls are provided by the LPE Standard T001 e Loading Profile Settings Table e Loading Profile Parameters Table e Default Time Configuration Table e Included Data Table e Data Time Configuration Table e Excluded Data Table e Menu Bar e Dropping of Items 2 3 3 2 Loading Profile Settings Table The standard Loading Profile Settings table is being used by the LPE Standard T001 see point 2 3 2 2 English Release 2012 09 29 44 SIPLUS CMS X Tools User Manual 07 Storage System
72. vice Profile Editor IPE Socket T001 green text is being used for controls like tables and trees o examples Main Profile Settings table Device Profile Data table orange text is being used for simple controls like a menu button a single row column cell of a table or a branch of a tree o examples Open menu button IP Address column Target Device Name cell Interfaces Branch dark yellow text is being used for the entries of context menus o examples Advanced Append Edit Camel Notation is being used for major terms of X Tools o examples Main Profile Interface Profile User Accounts File Analyzing Function and gt brackets are being used for keyboard keys o examples Ctrl Alt lt Shift gt Del and brackets are being used for mouse operations o examples left mouse button down mouse move Release 2012 09 8 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 Storage System 2 1 Storage System Explorer 2 1 1 Overview The Storage System Explorer in the following the STS Explorer is used in order to visualize and maintain all of the files and modules which are relevant for the Storage System It is displayed as a tree which contains all of the relevant and available Storage System items Via Drag amp Drop the user is able to move items within the STS Explorer and from the STS Explorer to other dialogs of the Storage System The following lines provide a short overview about the inf
73. ws to switch between the available decimal precisions Export Mode contains the export mode which shall be applied Export Parameters contains the export parameters which shall be applied Time Input Mode allows to switch between the available time input modes Time Domain allows to switch between the available time domains Minimum Time Format allows to switch between the available input formats for the minimum time Minimum Time Value allows to enter the minimum time of the data which shall be loaded Time Interval Format allows to switch between the available input formats of the time interval Time Interval Value allows to enter the time interval of the data which shall be loaded Maximum Time Format allows to switch between the available input formats for the maximum time Maximum Time Value allows to enter the maximum time of the of the data which shall be loaded English Release 2012 09 41144 SIPLUS CMS X Tools User Manual 07 Storage System Used Loading Profile SIPLUS CMS In case the user enters the path to a valid Loading Profile into this control the ODL uses the specified settings from the Loading Profile and exports the data from the offline data files at the disk accordingly When no Load ing Profile is being specified the data out of all currently selected offline data files is being exported Export Location The desired export location f
74. ximum Time Format Maximum Time Value Default N A Default N A N A N A N A N A N A N A Cancel Figure 9 Example of an Advanced Append Dialog English Release 2012 09 38 44 SIPLUS CMS X Tools User Manual 07 Storage System SIPLUS CMS 2 4 2 9 2 Appending Parameters Table The Appending Parameters table contains parameters which shall be applied when the selected offline data files are being loaded Parameter Description Used Loading Profile displays the currently chosen Loading Profile a double click onto this control opens the Select File dialog in order to choose another Loading Profile Loading Mode contains the loading mode which shall be applied Loading Parameters contains the loading parameters which shall be applied Time Input Mode allows to switch between the available time input modes Time Domain allows to switch between the available time domains Minimum Time Format allows to switch between the available input formats for the minimum time Minimum Time Value allows to enter the minimum time of the data which shall be loaded Time Interval Format allows to switch between the available input formats of the time interval Time Interval Value allows to enter the time interval of the data which shall be loaded Maximum Time Format allows to switch between the available input formats for the maximum time Maximum Time Va