1. 10 Do not dip the nebulizer in water 11 Children should only use the device under adult supervision 12 To avoid infections and contagion the accessories should not be shared by different patients They are intended for personal use 13 Use the unit intermittently Maximum operating period 30 minutes Rest period 30 minutes 14 Graham Field warrants the quality of the liquid contained in the Closed Water Chamber for a period of 3 years This solution can be changed easily by the authorized dealer 15 This device can only be repaired by the local dealer s authorized service agents Pan oaowpw ns Spare Parts Description Z __ Top cover Adapter Clear Housing Air Filter Main body Power Indicator ON OFF Switch Power Connector OPTIONAL Car lighter adapter OS Nasal piece oa Mouth piece Use Instructions 1 Take the unit and the AC adapter out of the box 2 Remove the clear housing and pour the medication into the medication container 8 ml Max ON OFF Switch 3 Add the clear housing and adapter and insert the device to be used into it adult mask pediatric mask and nasal or mouth piece CAUTION carefully check the membrane at the bottom of the medication cup before each use If it iS pierced or broken do not use the nebulizer and contact the authorized Service Agent 4 Attach the unit to the power connector 5 Press ON switch The green lig
2. NANO SONIC eS COMPRESSOR NEBULIZER MODEL JB0112 066 USER S MANUAL Read this manual before operating the nebulizer Save these instructions for future reference Caution Cease 7 Federal law restricts this device to sale by or on order of a physician or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device J B0112 066 INS LABR evA05 Contents MOGUCOM lt i os need eek eed EN UESENSEN SENSO Aas Eaa SRSA RE RN RAERDE a 2 SYMONS ROY at aaae eoa ena a EA EA E ERAD AAE EEE bBo rb toro penis Wiens REA 2 Recommendations t tsara iiaiai aneia aaa bale AS nara A 3 Spare Parts DescripiOn csrirrisiisii sii ririo rei kipada Ra aai 4 Use INSWUCHONS eriiriirririati ven ann EEE EE EEEE EEE PEPEES 5 Cleanand MaMtenantE ser niraeinramn a EE a piparaineed 6 Ric Fer CHANGE cirer ose cena na a hr Gere E EE ele AE RE 6 Accessories provided ck cnc cnceuransorbendse serbia ra laudan hai NEE 7 Opina lACCESSONES elira eaa EIEEE E EEA A AD EEE a E a A 7 Trouble Shooting Chate nea sc 0 00 ae are wine manna mbsan E A EA am i Technical SPeCHCAHONS cies iccis cds sievseeiveiverieevervaneesvrsreneeets 8 LV ese LIMMed Waman vkosccniey aid ep iaa eae nabadpe AN 9 Introduction Congratulations for having purchased a J ohn Bunn Nano Sonic Nebulizer Thanks for your support Graham Field warrants that this device has been produced using high quality materials and it complies
3. TEENOOR nea es 18 W QSCHANGHMEQUCREY aii miia oii anne As a a E REE ss 2 5 Mhz Neb lizaton Tate venenu neee ae ante mite o acales 0 5 ml min Particle dimension cc cece riani rrna 1 5 5 7 MMAD 3 8 micrones Medication cup maximum capacity 06 c eee eect eeet eee 8 ml WENE cs on5 9 49 88 tord 5 96 09 ein a boas 8 wh rind aude 0 57 Ibs 260 g Device dIMENSIONS mariinien E enw EE E dade 3 2 x 6 6 x 2 3 83 5 x 169 x 60 mm Operating temperature and humidity 41 to 104 F 30 to 95 RH 52 to 402 C 30 to 95 RH Storage temperature and humidity 33 8 to 104 F 10 to 95 RH 12 to 402C 10 to 95 RH Atmospheric pressure range for transport and storage 005 500 1060 mb The Closed Water Chamber contains a solution of Benzalkonium Chloride at 0 01 The specifications and the outer design are subject to change for improvement reasons without previous notice 3 Year Limited Warranty Graham F ield warrants to the origina in material and workmanship for a warranty does not cover failures resu retail purchaser that this product is free from defects period of 3 years from the date of purchase This ting from misuse abuse alteration of the J ohn Bunn Nebulizer System use of improper components or failure to comply with the operating instructions This warranty does not i All requests for warranty service sh Nebulizer System proof of purchase the nature of your
4. air chamber from the medication cup cover 3 Take out the filter and place a new one 4 Putall the pieces back Accessories Provided 1 Pediatric mask 1 Adult mask 1 Adapter 1 Nasal piece 2 Air Filters 1 Mouth piece 1 AC Adapter 1 Instruction Manual and Warranty Optional Accessories 1 Car lighter adapter 1 portable battery pack Trouble Shooting Chart If something wrong happens while the device is working please check and correct the following points 1 Check the plug is 1 Incorrectly connected to Although the power source properly connected device is on it 2 Check that power is on 2 No power ee 3 The AC Adapter is not connected 3 Check the AC Adapter is properly connected The mist does i TEAR Pour some drug solution There is no solution in the cup nai not come out into the medication cup 1 The air filter is dirty 1 Change the filter 2 There is not enough 2 Pour drug solution into Little mist is solution in the cup the medication cup delivered 3 Little power 3 Increase the power 4 Air excess 4 Regulate the air flow The device operates for a i Press the key twice and f Timer off i F period and then turn it on again turns off Technical Specifications Method of nebulization icc retinae Ultrasonic vibration Operating Voltage nsaisan eaaa aaia iann 110V 120V 220V 230V 240V 50Hz 60Hz Clas Seer E E a OE E Class Il POWER aaien tnd weed annclage data dacga i aeied PAN uae Masha
5. ht will turn on and the unit will start to operate Adjust the air regulator to the desired intensity 6 The unit will automatically turn off at 3 minutes If you wish to continue nebulizing check if the medication amount in the pool is sufficient Add more if necessary Then press the ON OFF switch twice and the unit will start to operate again 7 Once use is over unplug the equipment and disconnect the AC adapter Remove the clear housing and clean using a clean cloth Cleaning and Maintenance Important Clean the accessories before using the nebulizer for the first time or after each use following these instructions wash all the pieces except for the air filter with warm water and detergent Rinse with warm tap water to remove the detergent Dip the pieces into a clean bowl containing 3 parts warm water and 1 part vinegar let soak for 30 minutes Disinfectant can also be used Wash your hands and remove the pieces from the cleaning solution Rinse them with warm tap water and let them air dry Keep the pieces into a tightly sealed bag Do not dry them with a towel Clean the outer surface with a dry piece of cloth WARNING In order to avoid infections it is highly recommended to clean the pieces after each use Only nebulize solutions prescribed by a doctor and follow the doctor s instructions carefully Do not use balm substances Air Filter Change 1 The air filter must to be replaced if it turns dirty or torn 2 Remove the
6. service request G by this limited warranty THIS LIMITED WARRANTY IS IN LIE WRITTEN EXPRESS OR IMP ERCHANTABILITY OR FITNESS THOSE IMPLIED WARRANTIES A nclude the Nebulizer System tubing or accessories ould include the model number of your J ohn Bunn including date of purchase your phone number and raham Field will either repair or at its option replace ree of charge any parts necessary to correct defects in material or workmanship covered U OF ALLOTHER WARRANTIES WHETHER ORAL LIED THERE ARE NO WARRANTIES OF FOR A PARTICULAR PURPOSE EXCEPT FOR RISING BY OPERATION OF LAW WHICH ARE LIMITED IN DURATION TO THE 1YEAR TERM OF THIS WARRANTY GRAHAM FIELD S LIABILITY WHETHER BASED ON CONTRACT TORT WARRANTY STRICT LIABILITY OR ANY OTHER THEORY SHALL NOT EXCEED THE PRICE OF THE INDIVIDUAL OHN BUNN NEBULIZER SYSTEM WHIC H IS THE BASIS OF THE CLAIM IN NO EVENT SHALL GRAHAM FIELD BE LIABLE FOR ANY LOSS OF PROFITS FACILITIES EQUIPMENT OR OTHER INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES Some states do not allow limitations exclusion or limitation of incidental on how long an implied warranty lasts or allow the consequential or special damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state U S A Corporate Headquarters Graham Field Health Products 2935 Nor
7. theast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 http www grahamfield com J BO112 066 INS LABRevA0S NECO 21180
8. with the safety rules in force both domestically and internationally The J ohn Bunn Nano Sonic Nebulizer operates on ultrasound which produces the drug solution vibration and turns it into mist Effective and quick results are achieved without side effects This model comes with the exclusive Closed Water Chamber System easy to use All you need to do is pour the solution into the medication cup and it is ready to use Symbols key Off Customize nebulizing 8 O TYPO Birsin DCatisnpnnimunn ra Read the instructions A It operates on three types of power sources the main supply via AC adapter the optional car lighter adapter and the optional rechargeable battery pack CAUTION As per USA Federal regulations this product can only be sold under medical prescription Recommendations 1 Read the manual carefully before using the device and keep it in case you need urther information in the future Do not turn the device on if there is no drug solution in the medication cup Disconnect the nebulizer when it is not being used Do not remove the medication cup cover while the device is operating Do not expose the nebulizer to a heat source Do not pour more than 8 ml of solution into the medication cup Do not leave drug solution in the medication cup when the device is not being used Do not scrape or pierce the medication cup cover Do not touch the medication cup or the drug solution while the device is being used

Download Pdf Manuals

image

Related Search

Related Contents

DVPro T10 - T2  Massive Suspension light 36845/33/10  The KPhotoAlbum Handbook - Photos from our travels  ドーンぺ丿レギャンガ一へ丿レメット DH00ー/D=002/DH003/DH004  Products Range 2015    Instruction Manual - Cole  Vipower VP- 1028LSF IDE TO USB2.0 SWAPRACK MOBILE RACK Drive Case - VP-1028    SCM-54 Rev_4 Manuale montaggio serie LUCKY NEW.cdr  