Home
CSI 3372 Manual
Contents
1. 11 SO pu E ERST 12 RS Iype Data Selttihigs ooo 12 Data 13 Data Configuration Card Version 14 Rate Settligs cues khoe ro oo Rein DE TIT sages risale porc XE 15 16 16 Date 17 maiat LEDS M 18 Operating uy yuy EE k PUEDE PIRE VEU 20 1 1 8 1 20 Maintenance and Repairs 21 Secun m 21 VIS MERETRICIS 22 Accessories and Related Products 23 Page 2 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Welcome Features Package Contents Welcome Thank you for purchasing Communications Specialties Inc s Fiberlink 3370 Series The 3370 Series is used to transmit 3G HD SD SDI over one single mode fiber or two multimode fibers as well as 10 100 Ethernet and two channels of RS Type data The Fiberlink 3370 series is compatible with single mode or multimode fiber The system delivers noise free transmission that retains all of the signals initial parameters regardless
2. General Specifications Indicators Box Version Dimensions Weight Number of slots in 6000A card cage Power Operating Temperature MTBF Data Specifications Data Channels Data Bandwidth Control Format Protocols Signal Connectors Page 4 Technical Specifications Part Number 3370 B7L LC 3370 C7L LC 3371 B7L LC 3371 C7L LC 3372 B7L LC 3372 C7L LC 3373 B7L LC 3373 C7L LC 3370 B7S ST 3370 C7S ST 3371 B7S ST 3371 C7S ST 3372 B7S ST 3372 C7S ST 3373 B7S ST 3373 C7S ST xo Sxe S xo S uv Power Data Rate lock 3G HD SD Alarm card version only RS Data Channel 1 RS Data Channel 2 amp Ethernet LEDs on RJ 45 Connector 6 5Wx1 15Hx 8 L inches 165 W x 29 H x 203 L mm approx 1 16 0 45 kg 2 9 24 volts AC or DC 3370 4 8 watts 16 4 BTU Hr 3371 4 65 watt s 15 87 BTU Hr 10 C to 50 C 36 000 Hours 2 Channels Bi Directional DC to 115 Kb sec max Switch selectable RS 232 RS 422 amp RS 485 4 wire or 2 wire NRZ NRZI RZ Manchester Bi phase Removable terminal block Data Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Technical Specifications Technical Specifications Ethernet Specifications Port 10 100 Base T RJ 45 connector Configured as MDI Speed 10 Mbps amp 100 Mbps Ethernet Switch Selectable Fiberlink 3370 Transmitter Specifications Serial Video BNC In
3. only 0025 inches 62 5 microns in diameter Single mode fiber optic cable has an even smaller core only 00032 to 0004 inches 8 10 microns This is smaller than a human hair Therefore any minute particles of dirt or dust can easily block the fiber from accepting or radiating light To prevent this from happening always use the provided dust caps when ever optical connectors are exposed to air It is also a good idea to gently clean the tip of an optical connector with a lint free cloth moistened with alcohol whenever dust is suspected The status of the LEDs should provide the first clue as to the origin of any operational failure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal connections are correct An optical power meter such as the Fiberlink 6615 a visible light source such as the Fiberlink 6610 and a Three Wavelength Light Source such as the Fiberlink 6620 can greatly assist and expedite troubleshooting of fiber optic transmission systems and are recommended tools all installers should have available Finally although multimode and single mode devices may look the same they will not operate properly together Using the wrong device or fiber can easily add more attenuation than specified resulting in poor overall performance It should be noted that some of our fiber optic products support both single mode and multimode fib
4. of fiber optic cable attenuation The 3370 Series also provides immunity to video pathological signals over the entire link budget and operating temperature range Features Transmit up to 2 channels of bi directional RS Type data Transmit 10 100 Base T Ethernet All data and ethernet channels available simultaneously SDI signal is equalized and re clocked prior to fiber optic transmission Receiver features a re clocked SDI output e Immunity to pathological patterns over entire link budget and operating temperature range e Compliant with SMPTE 259 2006 292 2006 424 2006 276M e Supports one single mode fiber or two multimode fibers e Supports 3G HD SD SDI inputs with or without embedded audio and data 14 dB Optical Link Budget 2 97 Gbps e Wide operating temperature range 10 C to 4509 C Available in Box and Card versions ST or LC connectors available e Designed and Manufactured in the USA by CSI Package Contents e One Fiberlink Unit 3370 3371 3372 or 3373 e This User s Manual e One Ethernet Crossover Cable Fiberlink 3370 Series User s Manual Page 3 Fiberlink 3370 Series Technical Specifications Model Part Number Specification Unit Type Transmitter Box 1 Fiber SM Transmitter Rack Card 1 Fiber SM Receiver Box 1 Fiber SM Receiver Rack Card 1 Fiber SM Transmitter Box 2 Fiber MM Transmitter Rack Card 2 Fiber MM Receiver Box 2 Fiber MM Receiver Rack Card 2 Fiber MM
5. systems and are recommended tools all installers should have available All other questions or comments should be directed to our Customer Service Department It should be noted that many problems can easily be solved by a simple telephone call If you suspect your problem is caused by the optics or the fiber optic cable and you have an optical power meter please take the appropriate measurements prior to contacting support ric FE ertifications C Fiberlink 3370 Series User s Manual Page 21 Fiberlink 3370 Series LIM ITEDIWARRANTY Communications Specialties Inc CSI warrants that for a period of three years after purchase by the Buyer this product will be free from defects in material and workmanship under normal use and service A Return Material Authorization RMA number must be obtained from CSI before any equipment is returned by the Buyer All materials must be shipped to CSI at the expense and risk of the Buyer CSI s obligation under this warranty will be limited at its option to either the repair or replacement of defective units including free materials and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or goodwill CSI shall not be obligated to replace or repair equipment that has been damaged by fire war acts of God or similar causes or equipment that has been serviced by unauthorized personnel altered improperl
6. 12345678910 12345678910 bik ATITA DATA CONFIG A DATA CONFIG B RS 485 422 4 Wire 12345678910 1234567 8 910 dal 441111 DATA CONFIG A DATA CONFIG B RS 485 2 Wire T R 12345678910 12345678910 TETTI 111111 DATA CONFIG A DATA CONFIG B Page 16 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Data Wiring Card Version Data Wiring RS Type data wiring for the Fiberlink 3370 Series card units is as follows G1234 G1234 RS 232 Input RS 232 Output G 1234 G1234 Fiberlink 3370 Series User s Manual Page 17 Fiberlink 3370 Series Indicator LEDs Indicator LEDs The Fiberlink 3370 Series has several indicator LEDs that are used to monitor the state of the unit Card versions have an additional Alarm LED Transmitter LEDs Status Definition On Indicates that correct power has been applied Off Indicates no 3G SDI data rate lock On Indicates 3G SDI data rate lock at 2 97 Gbps or 2 97 1 001 Gbps HD Rate Off Indicates no HD SDI data rate lock On Indicates HD SDI data rate lock at 1 485 Gbps or 1 485 1 001 Gbps SD Rate Off Indicates no SD SDI data rate lock On Indicates SD SDI data rate lock at 270 Mbps Data A Off Indicates no data present Blink Indicates data present electrical or optical Data B Off Indicates no data present Blink Indicates data present electrical or optical Alarm On Loss of input video card version only Note The HD and SD LEDs indicator
7. Communications Specialties Fiberlink 3370 User s Manual Fiberlink 3370 Series 3G HD SD SDI Transmission and 10 100 Ethernet amp 2 Channels of RS Type Data over one single mode or two multimode fibers Broadcast quality 3G HD SD SDI 10 100 Ethernet and 2 channels of RS Type data over one single mode or two multimode fibers All data channels are available simultaneously CSI zum World Headquarters 55 Cabot Court Hauppauge New York 11788 USA Tel 631 273 0404 Fax 631 273 1638 info commspecial com commspecial com Fiberlink 3370 Series Contents Contents WV CICOING NER TE T i TT 3 iz eI ROREM Toc NN 3 Package Contents pEREREA TA RI pO da ees eee PERDU REUS FEES 3 Technical Specifications Model Part Number Specifications 4 General Specifications 4 Transmitter Specifications sss kk EE XA VR ERR rs 5 Receiver SpeciflicationS 6 Operating Loss 7 Maximum Useable Distance 7 Alarm Switch Settings 8 Installation Instructions s su sp nu III 8 Data Configuration Box Version 10 Baud Rate Settings
8. TA CONFIG A DATA CONFIG B Fiberlink 3370 Series User s Manual Page 11 Fiberlink 3370 Series Data Configuration Box Version Ethernet Configurations 100 Base T Ethernet DATA CONFIG A DATA CONFIG B 1234567 89 1234567 89 BREESE SE 10 Base T Ethernet DATA CONFIG A DATA CONFIG B RS 232 E1234 6789 EH t DATA CONFIG A DATA CONFIG B RS 485 422 4 Wire E1234 6789 1234567 DATA CONFIG B 111 DATA CONFIG A RS 485 2 Wire T R 123456789 12345678 TN DATA CONFIG DATA CONFIG B Page 12 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Data Wiring Box Version Data Wiring RS Type data wiring for the Fiberlink 3370 Series is as follows RS 232 Input 1234 61234 Channel A Channel B RS 422 485 4 Wire Input G1234G1234 Channel A Channel B RS 485 2 Wire Input Output G1234G1234 1 Channel A Channel B Fiberlink 3370 Series User s Manual RS 232 Output G1234G4123 4 eooeoeooeo Channel A Channel B RS 422 485 4 Wire Output G 1234G1234 Oooeeoooee Channel A Channel B Page 13 Fiberlink 3370 Series Data Configuration Card Version Data Configuration Card Version The Fiberlink 3370 Series card units have two dip switch panels with 10 switches The first panel DATA CONFIG A r
9. epresents the Ethernet and RS Channel A configuration The second panel DATA CONFIG B represents RS Channel B configuration Note that all data channels are available simultaneously 1234567 8910 38488233 DATA CONFIG A T Data Mode Baud Rate 2 Wire 4 Wire Mode Termination Input 120 Ohm Termination Output 120 Ohm Ethernet 12345678910 DATA CONFIG B L Not Used Data Mode Baud Rate 2 4 Wire Mode Termination Input 120 Ohm Termination Output 120 Ohm Page 14 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Data Configuration Baud Rates Card Version Baud Rate Configuration 12345678910 1234567 8 910 DATA CONFIG A DATA CONFIG B 12345678910 12345678910 LUE DATA CONFIG A DATA CONFIG B 12345678910 12345678910 9600 BE BE DATA CONFIG A DATA CONFIG B 12345678910 12345678910 19 2k ia ala DATA CONFIG A DATA CONFIG B 12345678910 12345678910 zeae 11 DATA CONFIG A DATA CONFIG B 12345678910 12345678910 574 m DATA CONFIG A DATA CONFIG B 12345678910 12345678910 22 T TT DATA CONFIG A DATA CONFIG B Fiberlink 3370 Series User s Manual Page 15 Fiberlink 3370 Series Data Configuration Card Version Ethernet Configurations 2345678910 12345678910 10 Base T Ethernet DATA CONFIG A 12345678910 12345678910 DATA CONFIG B 100 Base T Ethernet DATA CONFIG A RS 232
10. er in the same unit If after reviewing the above possibilities the system is still not operating please contact the Customer Service Department for further assistance If you suspect your problem is caused by the optics or the fiber optic cable and you have an optical power meter please take the appropriate measurements prior to contacting support Page 20 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Maintenance and Repairs Certifications Maintenance and Repairs The Fiberlink 3370 Series has been manufactured using the latest semiconductor devices and techniques that electronic technology has to offer They have been designed for long reliable and trouble free service and are not normally field repairable Should difficulty be encountered Communications Specialties maintains a complete service facility to render accurate timely and reliable service of all products The only maintenance that can be provided by the user is to ascertain that optical connectors are free of dust or dirt that could interfere with light transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink 6615 a visible light source such as the Fiberlink 6610 and a Three Wavelength Light Source such as the Fiberlink 6620 can greatly assist and expedite troubleshooting of fiber optic transmission
11. guration Box Version Data Configuration Box Version The Fiberlink 3370 Series box units have two dip switch panels one with 10 switches one with 9 The first panel Data Config A represents the Ethernet and RS Channel A configuration The second panel Data Config B represents RS Channel B configuration Note that all data channels are available simultaneously 1234567 89 38488233 DATA CONFIG A T Data Mode Baud Rate 2 Wire 4 Wire Mode Termination Input 120 Ohm Termination Output 120 Ohm Ethernet 123456789 DATA CONFIG B TL Data Mode Baud Rate 2 Wire 4 Wire Mode Termination Input 120 Ohm Termination Output 120 Ohm Page 10 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Data Configuration Baud Rates Box Version Baud Rate Configuration 456789 DATA CONFIG B 2 E 2400 DATA CONFIG A 3456789 DATA CONFIG 123456789 1 4800 DATA CONFIG 3456789 DATA CONFIG B 123456789 1 9600 1 11 DATA CONFIG A 3456789 DATA CONFIG B 123456789 1 19 2 DATA CONFIG 3456789 DATA CONFIG B 123456789 1 38 4k DATA CONFIG A 456789 DATA CONFIG B 123456789 1 57 6k 17111 DATA CONFIG A 2 456789 rw 1234567 89 1 76 8k 2 E DA
12. ical B to the receivers Optical B 7 Connectthe Universal Power Supply to the transmitter and receiver units For box versions using DC power please refer to figure 1 8 Configure your data preferences as described in the Data Configuration section of this manual 9 When power is applied the green POWER LED should illuminate indicating the presence of operating power The 3G HD SD RATE LED and the audio LEDs will give an indication as described in the Indicator LED s and Alarm Circuitry section of this manual 10 The system should now be operational Note The Rack Card version has an additional red LED for indicating the presence of an alarm condition loss of signal Refer to Indicator LED s and Alarm Circuitry sections of this manual Figure T Positive Power Connector 9 DC Input Polarity Negative 9 24 Volts AC or DC The transmitting element in the Fiberlink 3370 transmitter unit contains a solid state Laser Diode located in the optical connector This device emits invisible infrared electromag netic radiation which can be harmful to human eyes The radiation from this optical connector if viewed at close range with no fiber optic cable connected to the optical connector may be sufficient intensity to cause instantaneous damage to the retina of the eye Direct viewing of this radiation should be avoided at all times Fiberlink 3370 Series User s Manual Page 9 Fiberlink 3370 Series Data Confi
13. ink 3370 Series User s Manual Fiberlink 3370 Series Operating Loss Budget Maximum Useable Distance Fiberlink 3371 Receiver Specifications Operating Loss Budget Single Mode Fiber Multimode Fiber 62 5u Multimode Fiber 50u Maximum Useable Distance Single Mode Fiber Multimode Fiber 62 5u Multimode Fiber 50u 0 14 dB at 2 97 Gbps 0 17 dB at 1 485 Gbps 0 20 dB at 270 Mbps 0 14 dB at 2 97 Gbps 0 17 dB at 1 485 Gbps 0 20 dB at 270 Mbps 0 14 dB at 2 97 Gbps 0 17 dB at 1 485 Gbps 0 20 dB at 270 Mbps 30 km at 2 97 Gbps 48 km at 1 485 Gbps 50 km at 270 Mbps 0 8 km at 2 97 Gbps 1 km at 1 485 Gbps 2 5 km at 270 Mbps 1 km at 2 97 Gbps 1 3 km at 1 485 Gbps 3 km at 270 Mbps Distance specifications are approximate based upon connecting a 3370 Transmitter to a 3370 Receiver and are not guaranteed CSI cannot estimate or guarantee operating loss budgets when the 3370 Series is used with other non Fiberlink devices Operating loss budget must not be exce Fiberlink 3370 Series User s Manual 7 Fiberlink 3370 Series Alarm Switch Settings Installation Instructions Alarm Switch Settings amp Options The Rack Card version of this product has an additional red indicator LED that illuminates when an alarm condition exists The rack card unit also provides an output to drive a model 6020A Alarm Sensing Module which provides an audible tone and activates a set of contacts for exte
14. put Specifications Channels 2 Channels Bi Directional Data Bandwidth DC to 115 Kb sec max Control Format Switch selectable RS 232 RS 422 amp RS 485 4 wire or 2 wire Signal Connectors Removable terminal block Gbps and 350m at 270 Mbps Return Loss gt 10dB up to 2 97 Gbps Fiber Optic Output Specifications Connector LC or ST Wavelengths Used 1310nm 1490nm 1550nm Emmiter Type FP Laser Output Power nominal 4 5 dBm SDI Re clocking At 270 Mbps 1 485 Gbps amp 2 97 Gbps Fiberlink 3370 Series User s Manual Page 5 Fiberlink 3370 Series Technical Specifications Technical Specifications Fiberlink 3371 Receiver Specifications Fiber Optic Input Specifications Connector LC or ST Wavelength 1100 1620 nm Minimum Input Sensitivity 17 dBm at 2 97 Gbps 22 dBm at 1 485 Gbps 24 dBm at 270 Mbps Maximum Input Power 0 dBm Serial Video BNC Output Specifications Number of Outputs 1 Signal Level 800mV 10 DC Offset OV 0 5V Rise Fall Time lt 135 ps at 2 97 Gbps per SMPTE 424M lt 270 ps at 1 485 Gbps per SMPTE 292 0 4 ns to 1 5 ns at 270 Mbps per SMPTE 259M Overshoot 1096 of amplitude Timing Jitter lt 0 2 Ul at 270 Mbps 1 0 Ul at 1 485 Gbps lt 2 0 Ul at 2 97 Gbps with color bar signal Alignment Jitter lt 0 2 Ul at 270 Mbps lt 0 2 Ul at 1 485 Gbps lt 0 3 Ul at 2 97 Gbps with color bar signal Re clocking At 270 Mbps 1 485 Gbps amp 2 97 Gb Page 6 Fiberl
15. res Fiberlink 3370 Series User s Manual Page 23 Communications Specialties Fiberlink 3370 User s Manual Fiberlink 3370 Series 3G HD SD SDI Transmission and 10 100 Ethernet amp 2 Channels of RS Type Data over one single mode or two multimode fibers LE CSI zum World Headquarters 55 Cabot Court Hauppauge New York 11788 USA Tel 631 273 0404 Fax 631 273 1638 info commspecial com commspecial com 2011 Communications Specialties Inc All Rights Reserved Fiberlink and the starburst logo are registered trademarks of Communications Specialties Inc CSI and the triangle designs are trademarks of Communications Specialties Inc P N 128916 Rev E
16. rnal signaling purposes Alarm Switch Settings for the Transmitter Card Switch Position Alarm Indication On Off Loss of Input Video Enabled Disabled N A N A N A Alarm Indication On Off Loss of Optical Signal Enabled Disabled N A N A N A Installation Instructions The Fiberlink 3370 Series of fiber optic transmission systems are ready for immediate use and do not require any special tools or equipment The following instructions describe the typical installation procedure 1 Connect the video source to the video input BNC connector on the transmitter unit 2 Optional Connect your data connections as described in the Data Wiring section of this manual 3 Connect the video output cable to the video output BNC connectors on the receiver unit 4 Optional The ethernet port is configured as an MDI port If you are not connecting the 3370 Series to an auto crossover ethernet port you may need to use the ethernet crossover cable supplied with the unit to connect to another MDI port 5 Optional Connect your data connections as described in the Data Wiring section of this manual Page 8 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Installation Instructions Installation Instructions cont 6 Connect the fiber optic cable s to the transmitter and receiver units Note when using two fiber version you must connect the transmitters Optical A to the receivers Optical A and the transmitters Opt
17. s are off when a non standard signal is applied Page 18 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Receiver LEDs HD Rate SD Rate Data A Data B Alarm Status On Off On Off On Off On Off Blink Off Blink On Indicator LEDs Definition Indicates that correct power has been applied Indicates no 3G SDI data rate lock Indicates 3G SDI data rate lock at 2 97 Gbps or 2 97 1 001 Gbps Indicates no HD SDI data rate lock Indicates HD SDI data rate lock at 1 485 Gbps or 1 485 1 001 Gbps Indicates no SD SDI data rate lock Indicates SD SDI data rate lock at 270 Mbps Indicates no data present Indicates data present electrical or optical Indicates no data present Indicates data present electrical or optical Loss of optical signal card version only Note The HD and SD LEDs indicators are off when a non standard signal is applied Fiberlink 3370 Series User s Manual Page 19 Fiberlink 3370 Series Operating Pointers Troubleshooting Operating Pointers Remember to check attenuation of the fiber optic cable The system will only operate properly if these specifications fall within the range of the system s loss budget Note If no signal is applied to the 3370 Transmitter no optical power will be present on the 3370 Transmitter s output Troubleshooting Multimode fiber optic cable contains an optical fiber with a light carrying core that is
18. y installed or abused RMA numbers and repairs can be obtained from Communications Specialties Inc 55 Cabot Court Hauppauge NY 11788 USA Tel 631 273 0404 Fax 631 273 1638 RMA numbers can also be obtained from our web site commspecial com Please have your serial number available Page 22 Fiberlink 3370 Series User s Manual Fiberlink 3370 Series Accessories and Related Products Fiberlink 6610 Visible Light Source The Fiberlink Visible Light Source provides a visible 650 nm laser output that can be used for identifying fiber breaks and individual fibers within fiber bundles allowing for convenient on site testing of fiber networks during construction and maintenance procedures Fiberlink 6615 Optical Power Meter The Fiberlink Optical Power Meter measures the power of optical signals at 850 980 1310 and 1550 nm wavelengths allowing for convenient on site testing of fiber networks during construction and maintenance procedures It can be used to measure the power of an optical signal reaching the receiving end of a fiber optic cable as generated either by a transmitter unit or by a light source such as the 6620 Fiberlink 6620 Three Wavelength Light Source The Fiberlink Three Wavelength Light Source offers a laser output at wavelengths of 1310 and 1550 nm and VCSEL output at 850 nm allowing for convenient on site testing of fiber networks during construction and maintenance procedu
Download Pdf Manuals