Home
FAG Motion Guard C6-MP
Contents
1. FAG Motion Guard C6 MP DISTRIBUTOR Distributor User manual SCHAEFFLER wx amp Fac FAG Motion Guard C6 MP DISTRIBUTOR Distributor User manual SCHAEFFLER wx amp Fac 2 High product safety Follow instructions Definition of guidelines and BA 12 symbols Warning A Caution A Note O Original user manual Safety guidelines and symbols Our products correspond to the current level of research and technology If the bearing arrangement is designed correctly the products are handled and fitted correctly and as agreed and if they are maintained as instructed they do not give rise to any direct hazards This publication describes standard products Since these are used in numerous applications we cannot make a judgement as to whether any malfunctions will cause harm to persons or property Itis always and fundamentally the responsibility of the designer and user to ensure that all specifications are observed and that all necessary safety information is communicated to the end user This applies in particular to applications in which product failure and malfunction may constitute a hazard to human beings The warning and hazard symbols are defined along the lines of ANSI Z535 6 2006 The meaning ofthe guidelines and symbols is as follows If these safety guidelines are not observed death or serious injury may occur If these safety guidelines are not observed minor or slight injury will
2. provide the lubrication points with additional lubricant Check the following regularly the integrity and condition of the lubricator distributor connections and feed lines the residual volume of lubricant the position and fixing of all components The lubrication points can be manually greased with an additional quantity of lubricant at any time Press both keys on the lubricator The lubrication points are greased with lubrication at intervals of approximately 30 seconds If all the outlets are connected the greasing cycle will last a maximum of 14 minutes If both keys are pressed during a break duration 30 seconds a further greasing cycle is started when the current greasing cycle ends After an additional quantity of lubricant has been supplied or after a long period of machine stoppage weekends plant shutdowns the remaining running time of the lubrication system must be recalculated in accordance with the user manual for the lubricator This can be carried out using the software FAG Motion Guard Select Manager www schaeffler com services An additional lubricant quantity can only be supplied at an ambient temperature of more than 0 C The remaining running time which has been shortened as a result of the additional lubricant quantity must be taken into consideration in the lubrication and maintenance plan Schaeffler Technologies Switching off Lubrication system with lubricator FAG Motion Guard CONCEPT6 Ho
3. range from 20 C to 60 C Store the distributor in a dry dust free environment in the temperature range from 15 C to 25 C The information in this manual corresponded to the most recent status at the close of editing The illustrations and descriptions cannot be used as grounds for any claims relating to lubricators that have already been delivered Schaeffler Technologies AG amp Co KG accepts no liability for any damage or malfunctions if the lubrication system has been modified or used in an inappropriate manner BA12 5 6 Design and safety guidelines BA 12 Intended purpose Responsible persons Qualified personnel Protective equipment Lubrication system Caution A Warning A FAG Motion Guard C6 MP DISTRIBUTOR The distributor provides the same quantity of grease to up to six lubrication points Typical areas of application include the lubrication points on rolling and plain bearings drive and conveyor chains guidance systems open gearboxes and seals The operator and safety co ordinator are defined as responsible persons The operator is the natural or juristic person that uses the distributor or on whose instruction the distributor is used The distributor and lubrication system may only be operated by qualified personnel A person defined as qualified personnel is authorised to use the distributor by the safety co ordinator has all the necessary knowledge is familiar with the safety g
4. NCEPT 6 press the ON OFF SELECT key A long red arrow indicates that the key must pressed for at least four seconds 1 Delivered condition of fitted LC unit 2 Time setting and PIN reset display 3 PIN entry first digit 4 PIN entry second digit 5 Select volume of the LC unit 6 Set month weeks or days 7 Changing overto days or weeks Setting outlets Outlet 1 activated Outlet 2 activated a1 Change PIN first digit for initial configuration or following PIN reset only a2 Change PIN second digit for initial configuration or following PIN reset only a3 Configuration complete Ot OF Ot OF OF OF OF OF OF Of DIO Figure 5 Configuration menu S CE Ur Ot Ur Ur re 00014E88 Schaeffler Technologies BA12 11 Initialisation Switching on Automatic initialisation Example Figure 6 Display during initialisation routine 12 BA12 FAG Motion Guard C6 MP DISTRIBUTOR When switched on for the first time the lubrication system carries out automatic initialisation and begins to operate After replacing a distributor carry out manual initialisation The lubrication system is switched on using the lubricator FAG Motion Guard CONCEPT6 with battery set Hold the ON OFF SELECT key down until disappears in the display FAG Motion Guard CONCEPT6 CONTROL Apply the supply voltage will disappear in
5. ctor G s 6 pieces ARCALUB C6 JOINT MP 0 SET including closing plugs 4 pieces Elbow connector G s 6 pieces ARCALUB C6 JOINT MP 90 SET including closing plugs 4 pieces Lubricant feed line 5 m 8X1 5 mm ARCALUB C6 TUBE 5M inside diameter 5 mm Connector for lubricator ARCALUB C6 TUBEFIT G1 8 separate mounting Connector for distributor ARCALUB C6 TUBEFIT G3 8 separate mounting Connection cable 2m ARCALUB C6 CABLE 2M Holder ARCALUB C6 HOLDER Grease cartridge 400 g for prelubrication filled with Arcanol MULTITOP ARCANOL MULTITOP 400G filled with other lubricants Available by agreement ao a Connector straight type 2 Connector elbow type 3 Lubricant feed line 4 Holder 5 Connection cable 2 m 6 Grease cartridge Figure 10 Accessories 000 15AE4 Only use FAG accessories Caution A Service Distributors and empty lubricators can be sent to Schaeffler Technologies AG amp Co KG for disposal of used parts in an environmentally friendly manner replacement of LC units setting of the required lubricant quantity 20 BA12 Schaeffler Technologies EU Declaration of Conformity Figure 11 EU Declaration of Conformity Schaeffler Technologies A A Va Georg Schater Sir 30 AVA Keb 97421 Schweinfurt ah Au Declaration of Conformity for distributor FAG Motion Guard C6 MP DISTRIBUTOR EM lt gt Fac EU Declaration of Conformity In accordance with EG Machinery Directive 2006 42 EG and EMC D
6. distributor Observe the maximum torque of 2 Nm Connect the distributor and the lubricator using the lubricant feed line 8x 1 5 mm maximum length 2 m Connect the lubricant feed lines to the connectors of the distributor and lay to the lubrication points Observe the minimum bending radius of 40 mm Connect the lubricant feed lines to the lubrication points After ensuring that the components are switched off connect the lubricator and distributor using a long connection cable The lubrication system is now ready for operation Note When delivered the pump system in the lubricator is filled with universal grease After approximately ten greasing operations the universal grease is replaced by the grease from the LC unit 1 Hexagon head screws M6X25 for fixing to metal wall 2 Hexagon head screws M6X16 for distributor and holder IO maximum torque 3 Nm 510 3 Spacing 45 mm horizontal 6 0 4 Spacing 75 mm vertical Figure 4 Distributor separate mounting 000 15F8D E The maximum length of the lubricant feed lines of 5 m in each case includes the connection between the lubricator and distributor Schaeffler Technologies BA 12 9 10 Initial operation Caution A E Determining the lubricant quantity Setting the service life BA 12 Note Configuring outlets FAG Motion Guard C6 MP DISTRIBUTOR The service life and lubricant quantity are set on the lubricator after w
7. e ans AA dd 14 Additional lubricant Quantity csccccesscccessscceeseeceeeeeceeeess 14 SWI EC INS offorsi enti a Es USO ld E ue SPEED ETS RENE 15 Eliminating the malfunction cccccsseccesccesceessceeesceeeceenccs 16 ENORIMESS AD OS seara aii pude dd nbs Di da 17 DISTINTO isa danced aes nda BESES STER SEERE s 18 Replacement pan Seisein eaa 19 AES SOMES ai N rod add a PC a api 20 SOU VICE chs sanar nei tda ias canes eo E A tb O Ea 20 DAR O DO a ES UR ERE EE O O Ri a ESBEN E 21 Confieurine outlets assis sanada Pia Eds aaie Riad 22 Preparine the CISUMDUTOT sec cecsicadenescsa soctecestssedenseutdeseidevccdseieds 23 Mounting the lubrication system cscccessecccessccceeseeceeneceees 23 Determining the service life cccccesscccesseccceesceceesccceeseeceeusces 23 Switching on the lubrication system u ssseseeeeeeeeeeeeeeeeeeeneee 23 Switching off the lubrication system u sseseceeeeeeeeeeveree eneste 23 BA12 3 4 Features Scope of delivery 1 Distributor 2 Box of accessories 3 Connectors straight type CR 6 pieces 4 Connectors elbow type G1 g 6 pieces 5 Closing plugs G g 4 pieces 6 User manual 7 Connection cable short type C6 KIT only Drilling template C6 KIT only Holder C6 KIT only Lubricator C6 KIT only Figure 1 Scope of delivery Note BA 12 FAG Motion Guard C6 MP DISTRIBUTOR The FAG Motion Guard C6 MP DISTRIBUTOR provides lubrica
8. e table Reading on Defect Possible cause Remedy the display EO Lubricator has been switched off Defect on the lubrication point indicated F1 to F6 E2 Lubrication system has been switched off E3 Lubrication system has been switched off E4 Lubrication system has been switched off E5 The outlets are not set LC System does not detect an LC unit LO Lubrication only system CONCEPT6 CONTROL only Battery set CONCEPT6 discharged without voltage supply Excessive motor current in the distributor Excessive motor current the indicated outlet is blocked Replace the distributor Eliminate the blockage and acknowledge the defect press ON OFF SELECT or SELECT for longer than four seconds The outlets on the distributor were incorrectly detected Time overrun in control of the distributor Defective Replace connection cable the connection cable Replace the distributor Replace the distributor The drive unit of the lubricator is defective Replace the drive unit Configure the outlets switching off the voltage supply before acknowledging the defect inthe case of CONCEPT6 CONTROL The outlets were not configured LC unit missing Fit an LC unit Observe the user manual for the lubricator Lubricator is switched off Attach voltage supply Observe the user manual for the lubricator Replace battery set If the defect cannot be eliminated pl
9. ease contact Customer Service at Schaeffler Technologies AG amp Co KG BA12 17 FAG Motion Guard C6 MP DISTRIBUTOR Technical data Technical data see table Distributor Designation Technical data Length 148 mm Diameter 64 mm Mass approx 1 kg Number of outlets 6 Operating pressure max 25 bar Lubricants greases up to consistency class NLGI 2 Operating temperature 20 C to 60 C Voltage supply via connected FAG lubricator Threaded connector G inside for lubricator Threaded connector G g inside for lubricant feed line s Diameter 8X1 5 mm of lubricant feed line s inside diameter 5 mm Length max 5 m of lubricant feed line s see the user manual for the lubricator Protection class IP 54 O 1 Diameter Q2 2 Length O13 3 Threaded connector for lubricator 4 Jack for connection cable 5 Connection for connectors lubricant feed lines Figure 8 Distributor S 18 BA12 Schaeffler Technologies Replacement parts Component Ordering designation Distributor ARCALUB C6 DISTRIB MP Connection cable short type ARCALUB C6 CABLE MP Closing plug Available by agreement Oi y a 2 03 1 Distributor 2 Connection cable short type 3 Closing plug Figure 9 Replacement parts A Only FAG original replacement parts should be used Caution Schaeffler Technologies BA 12 19 FAG Motion Guard C6 MP DISTRIBUTOR Accessories Component Ordering designation Straight conne
10. g the distributor Screw connectors into the outlets to be used Screw closing plugs into the outlets that are not required NH Observe the maximum torque of 2 Nm for all screw connections Mounting Grease the lubrication points and lubricant feed lines with the lubrication system the same lubricant as in the LC unit of the lubricator Screw the lubricator and distributor Screw the holder firmly to the lubrication system Fix the holder and lubrication system to a rigid wall Connect the lubricant feed lines to the connectors of the distributor and lay to the lubrication points Maximum length of lubricant feed lines see user manual for CONCEPT6 or CONCEPT6 CONTROL With the lubrication system switched off connect the lubricator and distributor using a connection cable Determining the service life In accordance with the operating conditions determine the daily lubricant quantity The service life and setting mode are dependent on the volume of the LC unit lubricant cartridge The service life can be determined using the software FAG Motion Guard SELECT MANAGER www schaeffler com services E Only connect the lubrication points that require identical lubricant quantities Switching on Set service life or pulse operation size of the LC unit outlets and PIN the lubrication system n accordance with the user manual for the lubricator The lubrication system is switched on using the lubricator FAG Motion Guard CONCEPT6 H
11. hich the outlets are configured When the lubrication system is switched on automatic initialisation starts Once error free initialisation has taken place the lubrication system is ready and begins to operate Before initial operation ensure that the lubrication system is not damaged Before initial operation ensure that the lubrication system is correctly mounted set and greased Based on the operating conditions the lubricant quantity per lubrication point is determined The daily lubricant quantity is the number of lubrication points multiplied by the lubricant quantity per lubrication point The service life in days is determined from the volume of the lubricator divided by the daily lubricant quantity and can be set at any time on the lubricator without interrupting its operation Setting can be carried out while the lubrication system is switched on or off Set the service life according to the manual for the lubricator The service life dispensing time can be determined using the software FAG Motion Guard SELECT MANAGER www schaeffler com services At the time of delivery all the outlets are deactivated Once the distributor is connected configure the outlets according to the manual for the lubricator and Figure 5 page 11 Ensure that the lubricator is switched off while carrying out configuration Schaeffler Technologies Configuration In Figure 5 the SELECT key is shown When using FAG Motion Guard CO
12. icant feed lines supplied by Schaeffler Technologies AG amp Co KG Before joint or separate mounting fit the connectors Figure 2 Define the outlets to be used Screw connectors into the outlets to be used observing the maximum torque of 2 Nm Screw the closing plugs into the outlets not required 000 15A75 Do not loosen the screws on the underside of the distributor Do not open the distributor housing If these warnings are ignored this will invalidate the warranty BA12 7 Schaeffler Technologies FAG Motion Guard C6 MP DISTRIBUTOR Joint mounting In joint mounting the lubricator and distributor are screwed together the holder is screwed into place and then fixed to the machine Grease the lubrication points and lubricant feed lines with the same lubricant as in the LC unit Screw the lubricator and distributor together observing the maximum torque of 2 Nm Screw the holder to the lubrication system using support washers and hexagon head screws M6X 16 Screw the lubrication system and holderto a carrier assembly on the machine If a metallic base material is present use a minimum of three hexagon head screws M6X 25 the holes for the fixing screws should correspond to the drilling template and Figure 3 Connect the lubricant feed lines to the connectors of the distributor and lay to the lubrication points Observe the minimum bending radius of 40 mm Connect the lubricant feed lines to the lubrica
13. irective 2004405 EG We hereby declare that the product described below is in conformity with the applicable health and requirements of the EU Directive in terms of its design and type and in the execution we have brought into circulation This declaration shall cease to be valid if any modification is made to the product without our agreement Product description Distributor MP 6 for Lubricator of series CONCEPT Product name FAG Motion Guard C6 MP DISTRIBUTOR Type C6 MP DISTRIBUTOR Applicable harmonised standards EN 150 12100 1 2003 Safety of machinery Basic concepts general principles for design Part 1 Basic terminology and methodology EN 180 12100 2 2003 Safety of machinery Basic concepts general principles for design Pari 2 Technical principles EN 60204 1 2006 Electrical equipment of machines Signatures Schaeffler Technologies GmbH amp Co KG Services Industrial Aftermarke FS d IS Dipl Ing Armin Kempkes Michael Fassbinder vice President Services industrial Aftermarkos Product Manager Schaeffler Group Industrial FS Lubrication Products Date Schweinfurt 15 07 2010 This declaration certifies comloenity with the allied directives bul dors not repeosend a guaran es of characinris es The safely padelnas in the use manuel mubi be observed Schaefer Technologies GmbH amp Co KO Georg Schaler Siraibe 50 a D 57421 Sotvesinfurl Tel 40 20070140 00 BA 12 000 16F77 21 FAG Mo
14. ld the ON OFF SELECT key down until Vol disappears in the display and is replaced by Figure 7 Lubrication system with lubricator FAG Motion Guard CONCEPT6 CONTROL Disconnect from the voltage supply 1 Before switching off 2 After switching off Figure 7 Switching off switching on 00015A6E After switching off all the settings are saved After switching on greasing is continued at the point where it was stopped Schaeffler Technologies BA12 15 FAG Motion Guard C6 MP DISTRIBUTOR Malfunction Defects are detected by the controller and shown on the display of the lubricator The lubrication system will shut itself down until the defect has been eliminated and the error message has been acknowledged Eliminating the malfunction If a defect occurs the red LED will flash Localise the defect see table Error messages page 17 Eliminate the defect Acknowledge the error message ON OFF SELECT or SELECT Example The display shows F2 The pressure required at the second lubrication point is more than 25 bar The second lubrication point is not being greased Correct the defect present a blockage of the outlet or a kink in the lubricant feed line at the second lubrication point Acknowledge the error message 16 BA12 Schaeffler Technologies Error messages Defect cause remedy Schaeffler Technologies Localise and eliminate possible defect sources using th
15. nt to the lubrication points The maximum pressure is 25 bar The lubricant is supplied from an FAG lubricator The service life and lubricant quantity are set on the lubricator The lubricant cartridge in the lubricator is designated as an LC unit The unit comprising the lubricator and the distributor is the lubrication system The user manual must always be complete and in a legible condition Users of the distributor must have this user manual available and must observe the information in the manual The items included in delivery are shown in Figure 1 00016346 Check the delivery and report any damage in transit as a complaint to the deliverer Any missing items or other defects must be reported as a complaint to Schaeffler Technologies AG amp Co KG Schaeffler Technologies AG amp Co KG accepts no liability for any defects that are the subject of retrospective complaints Schaeffler Technologies Ambient conditions Operating temperature Storage Legal guidelines Schaeffler Technologies If the distributor is screwed together correctly with the lubricator it is resistant to dust and spray water However the sealing rings and plastics may be attacked by ambient media Uniform dispensing of lubricant and pressure build up to a maximum of 25 bar can only be ensured at operating temperature Protect the distributor against chemically aggressive environments The distributor can be used in the temperature
16. occur If these safety guidelines are not observed damage or malfunctions in the product or the adjacent construction will occur There follows additional or more detailed information that must be observed Numbers within a circle are item numbers This user manual is the original user manual in accordance with the Machinery Directive 2006 42 EC Schaeffler Technologies Features Design and safety guidelines Mounting Initial operation Operation Malfunction Technical data EU Declaration of Conformity Quick guide manual Schaeffler Technologies FAG Motion Guard C6 MP DISTRIBUTOR Page SCOPE OF delivery sam sssaiai ei qecar a ares a area Seis a DS 4 AMIBDICNE CONdIHONS iscas seia decr eee Las Ra aaa se tose 5 FESTE RES aps REDOR PR ER 5 LCN CEC purpose quase aid ad ai Lad 6 RESDONSIDIE persons ora Ea AE 6 Qual personnel ss casas regata Cisnes saca lisa Jus E 6 Protective CQUIDMENT issccs csscevsccssscasscensacseseseveaseasses savedevensaaeeees 6 LUDFIC ATOM Syste ssctecwuscaczivnadastcinedesteeeaeted debater doadas asia ai 6 MIGU TENS OF CONMCCEOLS siro renee JON TMOUN TINS ANN RS RN END RR SR 8 Separate mounn E us sites gira sda riso das ras aged free fore duas apanhada pas 9 Determining the lubricant Quantity cccceeescccessscceeseeceeneees 10 Setting the service e crisis darkness keen ede 10 Confisurins outlets oak ere cebalabdessenesoadeeueadaedt 10 Minal HOS ae re E a 12 INSPECTION aar sern
17. old the ON OFF SELECT key down until disappears in the display FAG Motion Guard CONCEPT6 CONTROL Apply the supply voltage will disappear in the display The lubrication system will now carry out automatic initialisation during which the outlets used are activated and shown in the display After initialisation the residual volume is shown and the lubrication system begins to operate Switching off After switching off all the settings are saved After switching on the lubrication system greasing is continued at the point where it was stopped Schaeffler Technologies BA12 23 MATNR 036859923 0000 BA12 01 GB D 2012091 Printed in Germany by hofmann Schaeffler Technologies AG amp Co KG Postfach 1260 97419 Schweinfurt Germany Georg Schdfer StraBe 30 97421 Schweinfurt Germany Phone 49 2407 9149 99 Fax 49 2407 9149 59 E mail support is schaeffler com Internet www schaeffler com services Every care has been taken to ensure the correctness of the information contained in this publication but no liability can be accepted for any errors or omissions We reserve the right to make technical changes Schaeffler Technologies AG amp Co KG Issued 2012 September This publication or parts thereof may not be reproduced without our permission BA 12 GB D
18. the display The lubricant system will check the outlets and show each connected outlet by means of a black square Outlets 1 2 3 and 6 are connected Figure 6 000 15A69 After automatic initialisation the display on the lubricator shows the following the connected outlets the residual volume in the lubricator The green LED flashes while the lubrication system is operating After initialisation check whether all the connected outlets are represented as black squares in the display Schaeffler Technologies Manual initialisation Before manual initialisation the lubrication system must be switched off check that is shown in the display Lubrication system with FAG Motion Guard CONCEPT6 Press the keys on the lubricator at the same time for longer than 4 seconds The display will show the system is switched off Lubrication system with FAG Motion Guard CONCEPT6 CONTROL Press the keys on the lubricator at the same time for longer than 4 seconds Wait for In to flash Activate the supply voltage The display will show Vol the system is switched on E After initialisation check whether all the connected outlets are represented as black squares in the display Schaeffler Technologies BA 12 13 Additional lubricant quantity 14 BA 12 Operation Inspection FAG Motion Guard C6 MP DISTRIBUTOR Check the lubrication system regularly during operation and if necessary
19. tion Guard C6 MP DISTRIBUTOR Quick guide manual This quick guide manual contains the most important guidelines on the use and setting of the distributor EH The quick guide manual is not a substitute for the detailed user manual Observe the safety guidelines and detailed information see chapter Features page 4 to chapter Technical data page 18 This quick guide manual is only valid for the distributor FAG Motion Guard C6 MP DISTRIBUTOR in conjunction with the lubricators FAG Motion Guard CONCEPT6 or FAG Motion Guard CONCEPT6 CONTROL Configuring outlets One distributor can be used to grease up to six lubrication points At the time of delivery all the outlets are deactivated Once the distributor is connected configure the outlets according to the manual for the lubricator and Figure 4 EH Ensure that the lubricator is switched off while carrying out configuration ee Figure 12 D Configuration menu excerpt ee 000 16726 Configuration is carried out on the lubricator Figure 12 C Select the volume of the LC unit Press MODE SAVE for longer than four seconds Briefly press ON OFF SELECT or SELECT 2 Set month weeks or days 3 Change to days or weeks Press MODE SAVE for longer than four seconds Briefly press ON OFF SELECT or SELECT 4 Configure outlets Configure the remaining outputs in the same way 22 BA12 Schaeffler Technologies Preparin
20. tion points After ensuring that the components are switched off connect the lubricator and distributor using a short connection cable The lubrication system is now ready for operation Note When delivered the pump system in the lubricator is filled with universal grease After approximately ten greasing operations the universal grease is replaced by the grease from the LC unit 1 Hexagon head screws M6X25 for fixing to metal wall 2 Hexagon head screws M6X16 for distributor lubricator and holder maximum torque 3 Nm 3 Spacing 45 mm horizontal 4 Spacing 75 mm vertical 5 Total length with LC250 351 5 mm or with LC500 402 5 mm Figure 3 Lubrication system joint mounting 000 15F8B 8 BA12 Schaeffler Technologies Separate mounting The distributor and lubricator can be mounted separately In this case one connector each for the distributor and lubricator an additional holder and a long connection cable are required Grease the lubrication points and lubricant feed lines with the same lubricant as in the LC unit Fix the lubricator to the machine see the user manual for the lubricator Screw the holder to the distributor using support washers and hexagon head screws M6X16 Fix the distributor with the holder to a carrier assembly on the machine Figure 4 Screw the connector G s of the straight type accessory into the lubricator and the connector G s accessory into the
21. uidelines has read and understood this manual Protective equipment is intended to protect personnel against health hazards When working with the distributor the following protective equipment must be used at all times protective goggles Ifthe lubrication system fails take appropriate measures to prevent possibly material damage Do not modify the distributor Keep grease away from eyes skin and clothing Observe the safety data sheets for the greases While working on machinery and plant the safety guidelines and user manuals of the manufacturers must be observed Schaeffler Technologies Mounting Fitting of connectors 1 Outlets 1 to 3 2 Housing with drive unit and distribution system 3 Connector for FAG lubricator 4 Drive unit with motor and electronics 5 Outlets 4 to 6 6 Socket for connection cable Figure 2 Lubricator FAG Motion Guard CONCEPT6 C6 MP DISTRIBUTOR Collect the material required for mounting Order accessories as appropriate see table Accessories page 20 The material required is as follows connectors lubricant feed line connection cable short type connection cable 2 m for separate mounting holder included in the KIT grease Cartridge 400 g for prelubrication lubricator included in the KIT connector G g for lubricator and connector G g for distributor only for separate mounting The distributor should be fitted exclusively with connector and lubr